HomeMy WebLinkAbout1497 ORDINANCE NO. 1497 AN ORDINANCE OF THE CITY COUNCIL OF THE CITY OF ARCADIA AMENDING SECTION 8130.35 OF THE ARCADIA MUNICIPAL CODE RELATING TO THE METHOD' OF INSTALLATION OF YARD STANDPIPE SYSTEMS FOR MULTIPLE DWELLING OCCUPANCIES. THE CITY COUNCIL OF THE CITY OF ARCADIA DOES ORDAIN .AS FOLLOWS: SECTION 1. Section 8130.35 of the Arcadia Municipal Code is hereby amended to read as follows: "8130.35. ADDITION. Section 1310 of Chapter 13 of said Uniform BUilding Code, Volume I, is hereby amended by adding thereto a new subsection (b), the same to read as follows: Sec. 1310 (b). Yard standpipe risers shall be provided whenever the front entrance to any dwelling unit or guest room is located more than 150 feet travel distance from the nearest street curb face, except that such risers shall not be required where all buildings on the premises are equipped throughout with automatic fire sprinkler systems 'installed in accordance with UBC.Standard No. 38-1. Said standpipe risers shall be so located that no front entrance to any dwelling unit or guest room on the premises is more than 75 feet travel distance from a standpipe riser or street curb face. 1. Size. The size of the standpipe riser shall be not less than two (2) inches in diameter. The size of the pipe supplying the risers shall not be less than two and one-half (2t) inches in diameter. The Chief of the Fire Department may require larger risers Dr supply piping if, in his opinion, it is deemed necessary by the configuration of supply pipe length and number of s~andpipe risers. 2. Outlets. All'standpipe risers shall be equipped with a one and one-half (It)' inch outlet valve with national -1- 1~7 j . standard male hose threads. Such valve shall be located not less than three (3) feet nor more than four (4) feet above grade. 3. Water supply. Such standpipe riser system shall be wet at all times and shall be connected to an adequate water supply. The supply pipe shall contain backflow devices as required by the Water Department and the Fire Department 4. Fire department connections. All standpipe riser systems shall be equipped with a two-way fire department connection. Piping from the connection inlet shall connect to the supply piping on the service side of the supply piping check valve. All fire department connections shall be located on a street front or, if approved by the. Fire Chief, adjacent to a paved access road on the property. Connections shall be not less than eighteen (18) inches nor m~re than four (4) feet above grade and shall be equipped with approved straight-way check valves. All fire depart- ment connections shall be protected against mechanical injury and shall be visible and accessible. More than one fire department connection may be required. 5. Signs. An approved durable sign with raised letters at least one (1) inch high shall be permanently attached to the street fire department connection. Such sign shall read: t STANDPIPE RISER CONNECTION. 1 11 SECTION 2. This is an emergency ordinance necessary for the preservation of the public peace, health and safety and shall go into effect upon its adoption. The facts constituting such necessity are that this ordinance regulates construction of multiple-family dwellings which present special fire prevention and suppression problems, and in order to meet these problems and protect the public health and safety, it is necessary that this ordinance take effect immediately. .. -2- 1497 SECTION 3. The City Clerk shall certify to the adoption of this ordinance. I HEREBY CERTIFY that the foregoing ordinance was adopted at a regular meeting of the City Council of the City of Arcadia held on the 16th day of October , 1973, by the affirmative vote of at least three Councilmen, to wit: AYES: Councilmen Butterworth, Helms, Scott and Arth NOES: None ABSENT: Councilman Hage SIGNED AND APPROVED this 16th day of October ,1973. ~,,Kc-teJ ~ Mayor of the Cit~ of Arcadia ATTEST: &:u~))tWr~ City Clerk (SEAL) .;'/ -;..- ~"- '.~--"":"':'= '/ .- -- ;?~::-~~~ ,. .:-- ,-" -" ...... . --....,.. v ....... --- -,~~:- -3- 1497