HomeMy WebLinkAbout2088 ORDINANCE NO. 2088 AN ORDINANCE OF THE CITY COUNCIL OF THE CITY OF ARCADIA, CALIFORNIA, AMENDING SECTION 8130.35 OF THE ARCADIA MUNICIPAL CODE RELATING TO SECTION 1208 - SOUND TRANSMISSION CONTROL. WHEREAS, this text change was initiated by the City at the request of Stonebridge Companies, to amend Section 8130.35 of the Arcadia Municipal Code relating to Sound Transmission Control. WHEREAS, a public hearing was held before the City Council on April 7, 1998, at which time all interested persons were given full opportunity to be heard and to present evidence; and WHEREAS, the City Council hereby finds that the revision to the building code standard of STC-58 to STC-52 provides adequate sound transmission controls for hotels and motels and better sound attenuation than the current Uniform Building Code Requirement of STC-50. WHEREAS, the City Council determines that based upon the evidence presented, the public necessity, convenience and general welfare justifies the proposed text change. NOW, THEREFORE, THE CITY COUNCIL OF THE CITY OF ARCADIA DOES HEREBY ORDAIN AS FOLLOWS: Section 1. That Section 8130.35 is amended to read as follows: 8130.35 AMENDMENT Volume 1, Appendix Chapter 12, Division II. in the Uniform Building Code is amended to read as follows: SECTION 1208 - SOUND TRANSMISSION CONTROL 1208.1 General. In Group R, Division 1 Occupancies, other than Multi-Family Buildings as defined in Arcadia Municipal Code Section 8130.53, every wall, partition or floor-ceiling assembly, forming a separation between a hotel room, between a motel room, between a guest room, between these rooms and garages or carports, or Zc/ordstc-52 Page 1 2088 between these rooms and common corridors, stairways or service areas, shall be provided airborne sound insulation for walls and both airborne and impact sound insulation for floor-ceiling assemblies. 1208.2 Airborne Sound Insulation. All such walls and floor-ceiling assemblies shall provide an airborne sound insulation equal to that required to meet a Sound Transmission Class (STC) of 52. Any penetrations or openings for construction assemblies, electrical, mechanical or plumbing devices or equipment shall first be approved by the Building Official and if approved shall be seal lined, insulated or otherwise treated to maintain the required ratings. Entrance doors from interior corridors together with the perimeter seals shall have a laboratory tested Sound Transmission Class (STC) of not less than 30 and such perimeter seals shall be maintained in good operating conditions. 1208.3 Impact Sound Insulation. All such floor-ceiling assemblies shall provide impact sound insulation equal to that required to meet an Impact Insulation Class (ITC) rating of 52. Floor coverings may be included in the assembly to obtain the required ratings, and must be retained as a permanent part of the assembly and may only be replaced by other floor coverings that provide the same sound insulation required above. 1208.4 Tested Assemblies. Field or laboratory tested wall or floor-ceiling designs having a STC or ITC rating of 52 or more, may be used without additional field testing when in the opinion of the Building Official the tested design has not been compromised by flanking paths. Tests may be required by the Building Official when evidence of compromised separations is noted. 1208.5 Field Testing and Certification. Field testing, when approved by the Building Official, shall be done under the supervision of a professional acoustical who shall be experienced in the field of acoustical testing and engineering, who shall forward certified test results to the Building Official that minimum sound insulation requirements stated above have been met. Zc/ordstc-52 Page 2 2088 1208.6 Airborne Sound Insulation Field Test. When approved by the Building Official, airborne sound insulation shall be determined according to the applicable Field Airborne Sound Transmission Loss Test Procedures. All sound transmitted from the source room to the receiving room shall be considered to be transmitted through the test partition. 1208.7 Impact Sound Insulation Field Test. When approved by the Building Official, impact sound insulation shall be determined. 1208.8 Field Tests for Existing Buildings. Field tests on existing buildings to determine the STC or ITC values, may be accomplished only upon authorization of the Building Official. Wall and floor-ceiling tests must meet a Sound Transmission Class and Impact Insulation Class (IIC) of 52. Section 2. The City Clerk shall certify to the adoption of this Ordinance and shall cause a copy of the same to be published in the official newspaper of said City within fifteen (15) days after its adoption. Passed, approved and adopted this 5th day of Hay , 1998. ~-4.~ May of the ity of Arcadia ATTEST: ~' o~~g Clerk of the C' of Arc dia Approved as to Form: ]f1~,!!c!j~ Zclordstc-52 Page 3 2088 STATE OF CALIFORNIA ) COUNTY OF LOS ANGELES ) SS: CITY OF ARCADIA ) I, JUNE D. ALFORD, City Clerk of the City of Arcadia, hereby certify that the foregoing Ordinance No. 2088 was passed and adopted by the City Council of the City of Arcadia, signed by the Mayor and attested to by the City Clerk at a regular meeting of said Council held on th(: 5th day of May, t 998 and that said Ordinance was adopted by the following vote, to wit: A YES: Councilmember Chandler, Harbicht, Marshall and Kovacic NOES: None ABSENT: Councilmember Roncelli ,d) f Arcadia Page 4 2088