ORDINANCE NO. 2015
AN ORDINANCE OF THE CITY COUNCIL OF THE CITY
OF ARCADIA, CALIFORNIA, AMENDING, DELETING AND
ADDING VARIOUS SECTIONS TO THE UNIFORM FIRE
CODE AND THE UNIFORM BUILDING CODE AS ADOPTED
BY THE ARCADIA MUNICIPAL CODE
THE CITY COUNCIL OF THE CITY OF ARCADIA, CALIFORNIA, DOES
HEREBY FIND, DETERMINE AND ORDAIN AS FOLLOWS:
SECTION 1. That the following Arcadia Municipal Code sections
are hereby amended to read as follows:
3115.1. AMENDMENT. section 14.104(b) of Article 14, is hereby
amended to read as follows:
Group B Occupancies: All per U.B.C. requirements.
3115.2.A. ADDITION.
section 10.204(a) of Chapter 10 of said Uniform Fire Code is
added to read as follows:
Dimensions.
Fire apparatus access roads shall have an
unobstructed width of not less than 20 feet and an unobstructed
vertical clearance of not less than 13 feet 6 inches.
1. When hydrants are required, fire apparatus access roads
shall have an unobstructed width of not less than 26 feet within a
linear distance of 25 feet each side of the hydrant.
3115.2.1.1. AMENDMENT.
Subsection (b) of said section 10.507 of said Fire Code is
hereby amended to read as follows:
(b) An automatic sprinkler system shall be installed in all
occupancies as set forth herein.
1
1. In every story or basement of all buildings when the floor
area exceeds 1,500 square feet and there is not provided at least
20 square feet of opening entirely above the adjoining ground level
in each 50 lineal feet or fraction thereof of exterior wall in the
story or basement on at least one side of the building. Openings
shall have a minimum dimension of not less than 30 inches. Such
openings shall be accessible to the fire department from the
exterior and shall not be obstructed in a manner that fire fighting
or rescue cannot be accomplished from the exterior.
When openings in a story are provided on only one side and the
opposite wall of such story is more than 75 feet from such
openings, the story shall be provided with an approved automatic
sprinkler system, or openings as specified above shall be provided
on at least two sides of an exterior wall of the story.
If any portion of a basement is located more than 75 feet from
openings required in this section, the basement shall be provided
with an approved automatic sprinkler system;
2. At the top of rubbish and linen chutes and in their
terminal rooms. Chutes extending though three or more floors shall
have additional sprinkler heads installed within such chutes at
al ternative floors. Sprinkler heads shall be accessible for
servicing.
3. In rooms where nitrate film is stored or handled;
4. In protected combustible fiber storage vaults as defined
in this code;
2
2015
5. In all buildings that exceed 5,000 square feet in total
area, regardless of type of construction. Note: Total area of
building is determined by measurement of the buildings exterior
walls.
6. In all convalescent and board and care facilities,
regardless of type of construction. said fire sprinkler system
shall comply with 1991 NFPA 13 Standard local amendments, as
determined by the Fire Department.
7. In all buildings more than two (2) stories in height,
regardless of occupancy or type of construction. Determination of
number of stories shall be made from the grade at the Fire
Department access.
8. In all buildings in the M-I and M-2 zones, regardless of
occupancy or type of construction.
3115.2.1.3. AMENDMENT.
section 10.507(h) of Article 10 of said Fire Code is hereby
amended to read as follows:
section 10.507. FIRE SPRINKLERS WHERE REQUIRED;
(h) Group R, Division I Occupancies.
1. An automatic fire sprinkler system shall be installed in
all mUltiple family dwellings, regardless of type of construction.
said fire sprinklers systems shall comply with 1991 NFPA 13, 13D,
or 13R Standards and local amendments, as determined by the Fire
Chief.
3
2015
(a) Any multiple family complex, greater than two (2)
units, not separated by twenty (20) feet of clear space between
structures, shall be protected by NFPA 13 or 13R system, as
determined by the Fire Department.
(b) Installations requiring NFPA 13R systems shall
conform to the NFPA 13R Standard with the following exceptions:
A minimum of 2 1/2 inch approved double detector check
backflow prevention device with 0 S & Y valves (not ball operated
valves) is required. Water supply may be less than 2 1/2 inch.
(c) NFPA 13R, section 2-4.2 is amended to read: At
least one 2 1/2 inch National Standard Thread, Fire Department
Connection shall be installed facinq the street.
(d) NFPA 13R, section 2-6, Exception 4 is amended to
read: Attics containing forced air units shall have installed one
or more 212 degree sprinkler heads adjacent to the forced air unit.
Sprinklers may be omitted from penthouse equipment rooms, crawl
spaces, floor/ceiling spaces, elevator shafts, and other concealed
spaces that are not used or intended for living purposes or are not
accessible for storage.
(e) Fire Department Connections shall be located within
ten (10) feet of the curb and shall be mounted no lower than 24
inches or no higher than 36 inches from finished grade.
(f) Garages shall have installed quick response, 200 or
212 degree heads (not residential quick response heads). An eight
(8) inch lintel/soffit shall be installed in any garage ceiling
with greater than four (4) heads. There shall be no more than four
4
2015
(4) heads in the soffit area.
3115.2.1.4. AMENDMENT. That the following is hereby added to
section 10.507(i) of said Fire Code to read as follows:
REQUIREMENTS FOR INSTALLATION
1. All fire sprinkler systems shall be installed by
California State Licensed C-16 contractors.
2. A complete set of working drawings and hydraulic
calculations shall be submitted to the Arcadia Building and Safety
Division. Working drawings and calculations shall conform to NFPA
13, section 6-1.
3. Plans must be submitted AND approved prior to the
installation of the fire sprinkler system.
4. An approved set of plans shall be maintained on the job
site at all times.
5. The flow switch shall be connected to horn and strobe
device, located directly outside of sleeping area.
6. Flow switch and smoke detectors shall be interconnected to
a visual and audible alarm.
MAINTENANCE
The owner is responsible for the maintenance and repair of the
sprinkler system at all times. The sprinkler contractor shall
provide the owner with a copy of NFPA 13 or appropriate NFPA
Standard at the time of final inspection.
All NFPA l3D Systems shall be certified by a state licensed
fire protection company every five (5) years from the date of
installation.
5
2015
3115.2.1.5. AMENDMENT. That section 10.507(j) of said Code
is hereby amended to read as follows:
(j) Retrofit
1. For additions to any existing building 5,000 square feet
or larger in total area, such buildings shall meet the requirement
for a new building.
2. Any building 5,000 square feet or larger in total area
that meets anyone of the following, will be required to install an
automatic fire sprinkler system within twelve (12) months from the
date permits are filed:
a. Any building that has a change in occupancy
classification that is more hazardous.
b. Any building vacant for more than 180 days.
3. For additions to existing Group R, Division 1 occupancies
that result in additional guest rooms or dwelling units, such
building shall meet the automatic fire sprinkler system
requirements for new construction throughout the building.
4. Existing single family dwellings shall meet the fire
sprinkler requirements for a new building when any of the following
occurs:
a. The building is enlarged by fifty (50%) percent or
more due to addition or add-on.
b. Fifty (50%) percent or more of the existing roof
structure is removed to add an additional story.
c. Fifty (50%) percent or more of the existing building
is affected by interior remodel, repair, or rebuild.
6
2015
d. A combination of remodel, rebuild, or repair with
additions or add-ons is equal to or greater than fifty (50%)
percent of the original building.
e. A second story, with sleeping rooms, is added to the
existing structure.
This policy will include existing code requirements for
buildings over 5,000 square feet and existing R-1 Occupancies.
section 10.508. SPRINKLER SYSTEM ALARMS. When serving more
than twenty (20) sprinkler heads, automatic sprinkler systems shall
be supervised by an approved U.L. certified central station
service, per NFPA 72, for all occupancies except R-3.
Exception: R-l and R-3 occupancies with sprinkler systems with
less than 100 heads.
3115.2.6. AMENDMENT. Section 78.103(c) is hereby added to
Article 78 of said Fire Code to read as follows:
PUBLIC DISPLAY. APPROVAL BY FIRE CHIEF.
Supervised public displays of fireworks or pyrotechnic
displays by a jurisdiction, fair, association, amusement park,
other organizations, or for the use of fireworks by artisans, in
pursuit of their trade, may be permitted, subject to the following
requirements.
a. The approval, by the Fire Chief, of a permit for public
display.
b. No permit shall be issued until the Fire Chief receives
documentation regarding the competence of the operator of the
fireworks, insurance, location of display, and other factors
7
2015
pertinent to the proposed display concerning the safety to persons
and property and proposed conditions to the permit required by the
Fire Code, or otherwise deemed necessary by the Fire Chief.
c. Permits for public display may be subject to regulations
and conditions approved by the Fire Chief as part of any action on
the permit, and the applicant shall be required to adhere to all
such conditions.
d. The Fire Chief may, in the exercise of his discretion,
deny any application, pursuant to the City's concern to protect
health, safety, and welfare.
e. That the City Council shall have the right to appeal any
decision of the Fire Chief.
SECTION 2. That a subsection (g) is hereby added to Section
3133.4 to read as follows:
(g) If after sufficient notice, compliance cannot be
obtained, the City will have the property cleared and a lien will
be levied against said property. For purposes of this section,
thirty (30) days shall be considered sufficient time for
compliance.
SECTION :3. That a new section 3134 is hereby added and
sections 3134 and 3134.1 are hereby renumbered to 3134.1 and 3134.2
to read as follows:
3134. BUILDING CONSTRUCTION GENERAL. Buildings or
structures, hereafter erected or constructed in Fire Zone 4, shall
have exterior construction equal to or greater than a one (1) hour
fire resistive rating.
8
2015
3134.1. SPARK ARRESTERS. EQUIPMENT.
3134.2. ENFORCEMENT.
SECTION 4. That Section 8130.13 of Chapter 16 of the Uniform
Building Code are hereby amended to read as follows:
section 1601. GENERAL. Buildings or structures, including
additions and remodeling, hereinafter erected, constructed, moved
within or into the hazardous fire areas as established by
resolution of the City council, shall comply with the following
requirements of this section:
(a) ROOFS. Roof coverings shall be as specified in Chapter
32, section 3203(a) and Appendix Chapter 32, section 3209 of the
Uniform Building Code.
(b) EXTERIOR WALLS. Exterior walls of all buildings or
structures shall have a fire-resistive rating of not less than one-
hour. All glazed openings including but not limited to windows,
skylights, doors, greenhouses, atriums or sunrooms shall be dual-
pane and meet California State Title-24 Energy U-Values when
required.
EXCEPTION:
1. Except where otherwise required by this Code, exterior
walls need not have a fire-resistive rating when any of the
following conditions exist:
a. Exterior walls that front on a public way having a
width of not less than 40 feet.
b. The building or structure is of Type 1 or II
construction.
9
2015
2. Glazed openings when consisting of assemblies of leaded,
faceted or carved glass when used for decorative purposes.
(c) PROJECTIONS. Eave overhangs, exterior balconies, decks
and similar architectural appendages extending beyond the floor
area as defined in the Uniform Building Code, section 407, shall be
of one-hour fire-resistive construction.
Underfloor areas not provided with a continuous surrounding
exterior wall shall be of one-hour fire-resistive construction.
EXCEPTION:
1. Except where otherwise required by this Code, projections
need not have a fire-resistive rating when any of the following
conditions exist:
a. Projections that front on a public way having a width
of not less than 40 feet.
b. projections of Type I or II construction.
(d) VENTILATION. Where determined necessary by the
enforcement agency, enclosed attics and enclosed rafter spaces
formed where ceilings are applied directly to the underside of roof
rafters shall have cross ventilation for each separate space by
ventilating openings protected against the entrance of rain. The
net free ventilating area shall not be less than 1/150 of the area
of the space ventilated and shall be installed in one of the
following methods.
a. By dormer vents placed in the lower 1/3 of the roof
rafter span length.
10
2015
b. By dormer vents which are half of the required area
placed in the lower 1/3 of the roof rafter span length and the
remaining half of the required area placed in the upper 2/3 of the
roof rafter span length.
c. By a combination of a or b above and gable vents
placed in gable end walls.
EXCEPTION: Except where otherwise required by this Code, eave
vents may be installed on building eaves which front on a public
way having a width of not less than 40 feet.
All vented openings shall be covered with corrosion-resistant
metal mesh with mesh openings of 1/4 inch in dimension.
SECTION 5. That section 8130.18 is hereby amended to read as
follows:
8130.18. AMENDMENT. Roof Covering Requirements. section
3203 of Chapter 32 of the Uniform Building Code is amended to read
as follows:
section 3203 (a) . GENERAL. Class A fire-resistive roof
coverings as specified in section 3204(a) on all structures in the
hazardous fire areas, regardless of occupancy group or construction
type.
Class A or B fire-resistive roof coverings as specified in
section 3204(a) or (b), shall be used on all structures in the non-
hazardous fire areas, regardless of occupancy group or construction
type.
11
2015
EXCEPTION. Ordinary roof coverings may be used in the non-
hazardous fire areas on Group M, Division 1 occupancies not
exceeding 120 square feet in floor area and 7 feet in height at its
highest point.
(b) STRUCTURAL ADDITIONS:
(i) Roofs of existing structures or buildings shall be
entirely covered with Class A roof covering as specified in section
3204(a) when any cumulative combination of additions, alterations,
replacements, repairs or reroofs to the existing roof is made which
exceeds 25% of the original roof area during the lifetime of the
building or structure.
(c) STRUCTURAL ADDITIONS IN NON-HAZARDOUS FIRE AREAS:
(i) 25% or Less - Roofs for structure or building additions
which together with those installed for additions during the
previous 12 month period do not cumulatively exceed 25% of the area
of the roof as it existed at the beginning of said 12 month period,
and any alterations, replacements or repairs to the existing roof,
required because of the addition, which do not together exceed 25%
of the area of the existing roof, may be made with material like
the material on the existing roof if said material was legal when
installed and if not legal when installed, then said covering as
specified in section 3204(a) or (b).
(ii) Over 25%-Less than 50% - Roofs for structure or building
additions which together with those installed for additions during
the previous 12 month period do cumulatively exceed 25% but are
cumulatively less than 50% of the area of said roof as it existed
12
2015
at the beginning of said 12 month period, and any alterations,
replacements or repairs to the existing roof required because of
the addition shall be Class A or B fire-resistive roof covering as
specified in section 3204(a) or (b).
(iii) 50% or More - Roofs for structure or building additions
which together with those installed for additions during the
previous 12 month period are cumulatively 50% or more of the area
of said roof as it existed at the beginning of said 12 month
period, and any alterations, replacements or repairs to the
existing roof required because of the addition shall be Class A or
B fire-resistive roof covering as specified in section 3204(a) or
(b), and if said required alterations, replacements or repairs
together exceed 50% of the area of the existing roof, then the
entire roof shall be replaced with the fire-resistive roof
covering.
SECTION 6. That section 8130.30 of the Arcadia Municipal Code
is hereby amended to read as follows:
section 8130.30. AMENDMENT. section 3209 of Chapter 32 of
the Appendix of said Uniform Building Code is amended to read as
follows:
section 3209(a). GENERAL - All reroofing shall be Class A
fire-resistive roof coverings as specified in section 3204(a) on
all structures in the hazardous fire areas, regardless of occupancy
group or construction type.
13
2015
All reroofing shall be Class A or B fire-resistive roof
coverings as specified in section 3204(a) or (b), on all structures
in the non-hazardous fire areas, regardless of occupancy or
construction type.
EXCEPTION: Ordinary roof coverings may be used in the non-
hazardous fire areas on Group M, Division 1 occupancies not
exceeding 120 square feet in floor area and 7 feet in height at its
highest point.
(b) REROOFS IN HAZARDOUS FIRE AREAS:
(i) Reroofs of existing structures or buildings shall be
entirely covered with Class A roof covering as specified in section
3204(a) when any cumulative combination of additions, alterations,
replacements, repairs or reroofs to the existing roof is made which
exceeds 25% of the original roof area during the lifetime of the
building or structure.
(c) REROOFS IN NON-HAZARDOUS FIRE AREAS:
(i) 25% or Less Reroofs for structure or building
additions which together with those installed for reroofs or
additions during the previous 12 month period do not cumulatively
exceed 25% of the area of the roof as it existed at the beginning
of said 12 month period, and any alterations, replacements or
repairs to the existing roof, required because of the reroof or
addition, which do not together exceed 25% of the area of the
existing roof, may be made with material like the material on the
existing roof if said material was legal when installed and if not
legal when installed, then said covering as specified in Section
14
2015
3204(a) or (b).
(ii) Over 25%-Less than 50% Reroofs for structure or
building additions which together with those installed for reroofs
or additions during the previous 12 month period do cumulatively
exceed 25% but are cumulatively less than 50% of the area of said
roof as it existed at the beginning of said 12 month period, and
any alterations, replacements or repairs or reroofs to the existing
roof shall be Class A or B fire-resistive roof covering as
specified in section 3204(a) or (b).
(iii) 50% or more Reroofs for structure or building
additions which together with those installed for reroofs or
additions during the previous 12 month period are cumulatively 50%
or more of the area of said roof as it existed at the beginning of
said 12 month period, and any alterations, replacements or repairs
or reroofs to the existing roof shall be Class A or B fire-
resistive roof covering as specified in section 3204(a) or (b), and
if said alterations, replacements, repairs or reroofs together
exceed 50% of the area of the existing roof, then the entire roof
shall be replaced with the fire-resistive roof covering.
SECTION 7. That the City Clerk shall certify to the adoption
of this Ordinance and shall cause a copy of same to be published in
the official newspaper of said City within fifteen (15) days after
its adoption.
15
2015
Passed, approved and adopted this 16th day of August 1994.
lP't!'~~#.
ATTEST:
of Arcadia
APPROVED AS TO FORM:
JrM:LJI m~
City of Arcadia
STATE OF CALIFORNIA
COUNTY OF LOS ANGELES SS:
CITY OF ARCADIA
I, JUNE D. ALFORD, City Clerk of the City of Arcadia, hereby
certify that the foregoing Ordinance No. 2015 was passed and
adopted by the City Council of the City of Arcadia, signed by the
Mayor and attested to by the City Clerk at a regular meeting of
said Council held on the +qtq day of August
1994 and that said
Ordinance was adopted by the following vote, to wit:
AYES: Councilmember Chang, .,Kuhn, Lojeski, Margett and Young
NOES: None
ABSENT: None
Arcadia
A9