Loading...
HomeMy WebLinkAboutItem 1 Resolutio No. 1961 - 501 N Santa Anita AveDATE: April 12, 2016 TO: Honorable Chairman and Planning Commission FROM: Jim Kasama, Community Development Administrator By: Jordan Chamberlin, Assistant Planner SUBJECT: RESOLUTION NO. 1961 – APPROVING MODIFICATION APPLICATION NO. MP 16-04, REVISIONS TO PREVIOUSLY APPROVED MULTIPLE- FAMILY ARCHITECTURAL DESIGN REVIEW NO. MFADR 14-09, AND EXTENSION REQUESTS FOR THE PREVIOUSLY APPROVED ZONE VARIANCE NO. ZV 15-02, MODIFICATION NO. MP 14-17, AND OAK TREE ENCROACHMENT PERMIT NO. TRE 14-30, WITH A CATEGORICAL EXEMPTION UNDER THE CALIFORNIA ENVIRONMENTAL QUALITY ACT (CEQA) FOR A 20-UNIT RESIDENTIAL CONDOMINIUM DEVELOPMENT AT 501 N. SANTA ANITA AVENUE Recommendation: Approve and Adopt Resolution No. 1961 SUMMARY The property owner/applicant, Mr. James Li, has submitted applications to revise the architectural design of a previously approved 20-unit, two-story, Contemporary-style, townhouse condominium development project. At its October 13, 2015, meeting, the Planning Commission adopted Resolution No. 1947 (Attachment No. 1) to conditionally approved Tentative Tract Map No. TTM 14-03 (73106), Zone Variance No. ZV 15-02, Modification No. MP 14-17, Oak Tree Encroachment Permit No. TRE 14-30, and Architectural Design Review No. MFADR 14-09. Shortly after the approval, the previous applicant sold the property and entitlements to Mr. Li who wishes to revise the design, and is requesting approval of the following: • Revisions to the previously approved Multiple-Family Architectural Design Review No. MFADR 14-09; • Modification Application No. MP 16-04 for setback and height modifications for a new wall and fence along Colorado Boulevard; and • Extension requests for the previously approved Zone Variance No. ZV 15-02 for 20 units in lieu of the minimum 23 required; Modification No. MP 14-17 for various Zoning Code adjustments; and Oak Tree Permit No. TRE 14-30 to encroach upon one oak tree. MP 16-04, MFADR 14-09, ZV 15-02, MP 14-17, and TRE 14-30 501 N. Santa Anita Avenue April 12, 2016 – Page 2 of 16 The proposed development qualifies for a Categorical Exemption as an in-fill development project under the California Environmental Quality Act (CEQA). It is recommended that the Planning Commission conditionally approve the applications and adopt Resolution No. 1961 (Attachment No. 2) to approve MP 16-04, revisions to MFADR 14-09, and extensions for ZV 15-02, MP 14-17, and TRE 14-30, with a CEQA exemption, subject to the conditions listed in this staff report. BACKGROUND The subject property is approximately 45,824 square feet (1.05 acres) in area and is zoned R-3, High Density Multiple-Family Residential. The lot is currently developed with a church that was constructed in 1953 - refer to Attachment No. 3 for an Aerial photo with Zoning Information and Photos of the Subject Property and Vicinity. The western portion of the site (the back half of the property) has a Public Utility Easement (PUE) on it that the City retained when a portion of Windsor Drive and Cornell Drive were vacated in 1953 for street realignment purposes. The vacated land was deeded to the adjacent property owner (the church site) and consolidated. The PUE is for all variety of public utilities; sanitary sewer, water, storm drains, electrical, gas, etc. There is also a 15’-0” storm drain easement along a portion of the north property line between Santa Anita Avenue and Windsor Road. At its October 13, 2015, meeting, the Planning Commission voted 4-1 to conditionally approve the construction of 20 residential condominium units in six, two-story, Contemporary style, townhome buildings (see Resolution No. 1947 - Attachment No. 1). The proposal included several entitlements, including: a Tentative Tract Map to subdivide the airspace, a Zone Variance to allow 20 dwelling units in lieu of the minimum 23 units required, Multiple-Family Architectural Design Review, an Oak Tree Encroachment Permit to allow building walls, perimeter garden walls, walkways, and landscaping within the protected area of one oak tree located adjacent to N. Santa Anita Avenue, and the following Zoning Modifications: Front yard setback along Santa Anita Avenue (first and second story): • 15’-0” in lieu of the 25’-0” required. Street side yard setback along Colorado Boulevard: • A 7’-7” to 21’-9” encroachment into the 75’-0” special setback along this portion of Colorado Boulevard; • A 10’-1” to 21’-9” building setback instead of the 25’-0” street side yard requirement; • To allow three air conditioning units to be located in the required street side yard setback for units 2, 3, and 11 (The revised plans have units 2 & 3 as units 1 & 2, and the location of the air conditioning unit for unit 11, which is now unit 13, has been revised to no longer require a modification); and MP 16-04, MFADR 14-09, ZV 15-02, MP 14-17, and TRE 14-30 501 N. Santa Anita Avenue April 12, 2016 – Page 3 of 16 • To allow one of the buildings to be 219’-0” in length in lieu of the 165’-0” maximum. Street side yard and front yard setbacks, and fence height along Colorado Boulevard for incidental structures: • A 7’-7” street side yard setback and 9’-0” front yard setback for an open stairwell and ADA chair lift adjacent to Colorado Boulevard in lieu of the 25’-0” required (the revised plans have replaced the chair lift with an ADA ramp); and • To allow 80’-0” of fencing adjacent to the property line to exceed 6’-0” in height with a maximum height of 8’-0” measured from the lowest adjacent grade. Interior side yard setback along Windsor Road and Cornell Drive: • To allow 85’-0” of fencing adjacent to the northerly interior side property line to exceed 6’-0” in height with a maximum height of 11’-6” measured from the lowest adjacent grade. As a part of the approval, the applicant made arrangements to obtain a portion of the City’s right-of-way along Colorado Boulevard to facilitate disabled accessibility between the subject site and the public sidewalk. The requested right-of-way area is unusable for public street purposes, but can be used for utilities. Therefore, the City will retain a public utility easement over the entire vacated portion. The Planning Commission found the proposed right-of-way vacation of portions of Colorado Boulevard to be consistent Figure 1. Image of the N. Santa Anita Avenue elevation for the previously approved design. Figure 2. Image of the Colorado Boulevard elevation for the previously approved design. MP 16-04, MFADR 14-09, ZV 15-02, MP 14-17, and TRE 14-30 501 N. Santa Anita Avenue April 12, 2016 – Page 4 of 16 with the City’s General Plan goals and policies, and a recommendation of approval is to be forwarded to the City Council. As a condition of approval, the applicant/property owner was required to enter in an agreement with the City and post security to construct a new sidewalk, retaining wall, and other associated elements along Colorado Boulevard. As for the public utility easement on the back-half of the property it will be quitclaimed to the property owner, but with new easements granted to the utility companies for their specific utility purposes. Lastly, a portion of the existing storm drain easement adjacent to the north property line, between Santa Anita Avenue and Windsor Road, will be reduced in width by five feet and a new easement adjacent to Windsor Road is to be granted to the City that connects directly to the existing storm drain easement at the back half of the property. With these adjustments, the lot area increases from 45,824 square feet to 51,462 square feet (1.18 acres). PROPOSAL On October 28, 2015, the previous property owner sold the property and the entitlements to Mr. James Li, due to the off-site improvements being a more significant undertaking than previously anticipated. The new property owner believes the requested architectural changes will make the development more marketable and has applied to revise the design approved by Multiple-Family Architectural Design Review No. MFADR 14-09. The revised proposal also includes height and setback modification requests for a new wall and fence along Colorado Boulevard. The conditions of approval for the applications that were approved by the Planning Commission in October 2015, are to remain applicable, but will be amended to address the revised architecture, new wall, and additional oak tree information - see Resolution No. 1961 (Attachment No. 2). Architectural Design The proposed architectural style remains Contemporary, but changes are proposed for the floor plans, elevations, roof plan, landscape plan, and the colors and materials. The project maintains the same setbacks that were previously approved by the Planning Commission, but portions of the layout, including building articulation are to be revised to be consistent with the architectural changes. Each two story unit will have at least three bedrooms and two and a half bathrooms, and will range from approximately 1,512 to 2,340 square feet of living area. The total building area of the project will be approximately 1,461 square feet less than the original proposal. The new buildings will have a maximum height of 28’-6”, which is similar to the previously approved design. All units will have the minimum requirement of 100 square feet a private outdoor area. Four units will face N. Santa Anita Avenue, seven units will face Colorado Boulevard, three units will face Windsor Road or Cornell Drive, and six units will face the north interior side property line. The revised design reconfigured one unit adjacent to Windsor Road to face the north interior side property line rather than the street. Vehicular access MP 16-04, MFADR 14-09, ZV 15-02, MP 14-17, and TRE 14-30 501 N. Santa Anita Avenue April 12, 2016 – Page 5 of 16 to the site is provided from Santa Anita Avenue through Newman Avenue, and then south to Windsor Road and Cornell Drive. There will be 50 on-site parking spaces, which meets the parking requirement. Of the 50 parking spaces provided, 38 will be semi-subterranean (30 garage spaces and eight guest parking spaces) and 12 will be surface parking (10 garage spaces and two guest parking spaces). Modifications for Wall and Fence Height The applicant is requesting approval of additional Zoning Modifications to allow 397’-0” of wall and fencing adjacent to the street side property line along Colorado Boulevard to exceed 6’-0” in height with a maximum height of 18’-5” measured from the lowest adjacent grade of the Colorado Boulevard right-of-way, and for portions of the wall and Figure 3. Image of the N. Santa Anita Avenue elevation for the revised design. Figure 4. Image of the Colorado Boulevard elevation for revised design. MP 16-04, MFADR 14-09, ZV 15-02, MP 14-17, and TRE 14-30 501 N. Santa Anita Avenue April 12, 2016 – Page 6 of 16 fencing to be located less than 18” from the street side property line along Colorado Boulevard. The maximum height of 18’-5” will be comprised of a 13’-11” tall concrete retaining wall and a 4’-6” high wrought-iron guard rail/fence. Extension Requests The applicant is also requesting approval of extensions for the previously approved Zone Variance No. ZV 15-02 to allow 20 units in lieu of the minimum 23 required, Modification No. MP 14-17 for the aforementioned Zoning Code adjustments, and Oak Tree Encroachment Permit No. TRE 14-30 to encroach upon one oak tree, but with revisions. ANALYSIS Architectural Style The Planning Commission is to approve, conditionally approve, or deny the revisions to the architectural design of the project. The revised architectural style of the development is described as Contemporary – see the above images and Attachment No. 4 for the revised Architectural Plans. The design is well conceived. The units facing N. Santa Anita Avenue and Colorado Boulevard will enhance the streetscape of this prominent corner. Metal-framed windows, a combination of flat and hipped roofs with brown metal standing-seam roofing, and thoughtfully placed architectural projections and balconies exemplify the Contemporary style. The majority of the parking is semi- subterranean and behind the buildings so that the architecture is the focus of the development as viewed from N. Santa Anita Avenue and Colorado Boulevard. Staff finds the massing, scale, quality of the design, and the landscaping to be consistent or superior to that of other developments in the area; however, staff has concerns with the proposed stone and stucco colors. The above images do not accurately depict the colors of the stone and stucco. Staff will have samples at the meeting. Staff feels that the colors of the stone and stucco give the proposal an industrial appearance that is inconsistent with the City’s Multiple-Family Residential Design Guidelines, and recommends as a condition of approval that the stone and/or stucco colors be revised to provide a residential appearance. The changes shall be subject to the Development Services Director, or designees, review and approval. Modifications The applicant is requesting approval of modifications to allow 397’-0” of wall and fencing adjacent to the street side property line along Colorado Boulevard to exceed 6’-0” in height with a maximum height of 18’-5” measured from the lowest adjacent grade along Colorado Boulevard. The maximum height of 18’-5” will be comprised of a 13’-11” tall concrete retaining wall and a 4’-6” high wrought-iron guard rail/fence. Colorado Boulevard descends underneath a bridge for the light-rail line west of N. Santa Anita Avenue. The subject property remains at the same elevation. This creates a grade difference between the street and the subject property. Currently there is a sloped MP 16-04, MFADR 14-09, ZV 15-02, MP 14-17, and TRE 14-30 501 N. Santa Anita Avenue April 12, 2016 – Page 7 of 16 concrete embankment, a portion of which failed during a recent storm. As a part of the project approval, the previous property owner made arrangements to obtain a portion of the City’s right-of-way along Colorado Boulevard, including the concrete slope, and construct a 5’-0” wide public sidewalk. The previous property owner planned on installing tree wells into the slope and planting vines on the slope to screen and enhance its appearance. The new property owner is proposing to remove the concrete embankment and construct a vertical retaining wall of varying heights with a 4’-6” tall wrought iron guard rail/fence on top. The Building Code requires that a minimum 3’-6” high safety railing be provided when the difference between grade levels is greater than 30-inches. The proposed 4’-6” fence height is for additional safety. The combined height of the wall and fence ranges from 6’-0” towards the easterly portion of the site to 18’-5” at the westerly end of the site adjacent to the light-rail right-of-way. A 5’-0” wide planter area is proposed next to the wall with Yew Pine shrubs to screen the wall. The proposed wall and fence will not adversely impact the streetscape since it will be screened with landscaping. As a condition of approval, staff recommends extending the proposed planting area along Colorado Boulevard an additional 65’-0” to the east to provide additional screening of the wall (i.e., a portion of the unscreened portion in the image below). There will be adequate space to also provide a 5’-0” wide public sidewalk along the entire Colorado Boulevard side of the site. The applicant is also requesting approval to allow 138’-0” of the wall and fence to be located less than 18” from the street side property line along Colorado Boulevard. On the subject property along Colorado Boulevard there are existing underground utilities that would be very costly to relocate. The proposed location of the wall allows the existing utilities to remain in their current locations. The reduced setback will have no impact to the streetscape. Figure 5. Image of the proposed new wall, fence, and landscaping along Colorado Boulevard. MP 16-04, MFADR 14-09, ZV 15-02, MP 14-17, and TRE 14-30 501 N. Santa Anita Avenue April 12, 2016 – Page 8 of 16 Extension Requests At its October 13, 2015 meeting, the Planning Commission voted 4-1 to conditionally approve the construction of a 20-unit, residential condominium development. The proposal included the following entitlements: Tentative Tract Map No. TTM 14-03 (73106), Zone Variance No. ZV 15-02; Zoning Modification No. MP 14-07; Oak Tree Encroachment Permit No. TRE 14-30; and Multiple-Family Architectural Design Review No. MFADR 14-09. The approvals of the Zone Variance, Modification, Oak Tree Encroachment Permit, and Architectural Design Review expire on October 24, 2016. The Tentative Tract Map expires on October 24, 2017. The architect, Mr. Jonathan Kelly of Tyler Gonzalez Architects, Inc., on behalf of the owner, filed extension requests for the Zone Variance, Modifications, and Oak Tree Encroachment Permit on March 11, 2016, citing that the property owner requested a redesign, which forestalled the preparing construction plans for submittal to Building Services for plan-check – refer to Attachment No. 5 for the extension request letters. The Zone Variance, Modifications, and Oak Tree Encroachment are still necessary for the revised project. Oak Tree Encroachment Mr. Kelly submitted an addendum to the previous Arborist Reports prepared by Carlberg Associates – refer to Attachment No. 6 for the Oak Tree Report and Addenda. The Certified Arborist, Ms. Christy Cuba determined that the minor changes made to the site plan will have slightly less impacts to the root zone of the Coast Live Oak tree because there will be less excavation. A walkway from the semi-subterranean parking area to the street level will remain, but a semi-subterranean parking space is to be relocated. However, there will be similar or slightly greater impacts to the outer canopy due to a building (Unit No. 10) being in place of the relocated semi-subterranean parking space, and located closer to the tree than with the previous design. With additional protective measures, however, the arborist does not anticipate that the increased encroachment will cause significant or detrimental impacts. These additional protective measures are to be included as conditions of approval. Staff recommends extending the approvals for Zone Variance No. ZV 15-02, Zoning Modification No. MP 14-07, and Oak Tree Encroachment Permit No TRE 14-30 for one year to October 24, 2017 to coincide with the expiration of the Tentative Tract Map. It should be noted that if the revisions to the Multiple-Family Architectural Design Review are approved, the new expiration date will be April 21, 2017. If the property owner is not able to submit construction plans to Building Services for plan check by April 21, 2017, the property owner may request an extension. The proposed development, with conditional approval of the Zone Variance, Oak Tree Encroachment, and the Zoning Modifications, will be consistent with the City’s General Plan, Multiple-Family Residential Design Guidelines, and the City’s Zoning Code. The proposed plans have been reviewed by the various City Departments and all City requirements shall be complied with to the satisfaction of the Building Official, City MP 16-04, MFADR 14-09, ZV 15-02, MP 14-17, and TRE 14-30 501 N. Santa Anita Avenue April 12, 2016 – Page 9 of 16 Engineer, Community Development Administrator, Fire Marshal, and Public Works Services Director, or their respective designees. FINDINGS Architectural Design Review The proposed Contemporary style architecture, its massing, scale, and quality of design, and the proposed landscaping will match or exceed the design characteristics and quality of the other developments in the area with the condition of approval that the stone and/or stucco color(s) be revised to provide a residential appearance that is consistent with the City’s Multiple-Family Residential Design Guidelines. Modifications Section 9292.1.4 of the Arcadia Municipal Code states that the purpose of the Modification procedures is for the following: 1. Secure an appropriate improvement of a lot; 2. Prevent an unreasonable hardship; or 3. Promote uniformity of development. The requested Modifications will allow the site to be developed in a manner similar to other R-3 zoned properties and will prevent an unreasonable hardship due to the significant grade difference between the subject property and Colorado Boulevard, and the various utilities that are located on the subject site along Colorado Boulevard. The Modifications will also secure appropriate improvements that will enhance the Colorado Boulevard streetscape and be compatible with the neighboring commercial and residential properties. Extension Requests An extension can only be granted if it is determined that the findings for the approval are still valid and the extension request is justifiable. Staff finds that all the original findings and conditions of approval for Zone Variance No. ZV 15-02, Zoning Modification No. MP 14-07, and Oak Tree Encroachment Permit No. TRE 14-30 remain valid and are still an integral part of the revised proposal. ENVIRONMENTAL ASSESSMENT For the previously approved project, an Initial Study was prepared to analyze its potential environmental impacts (refer to Attachment No. 7). In particular, the potential impacts associated with the adjacent light-rail right-of-way. The Initial Study determined that there are no significant impacts, and that the project is an infill development project that qualifies as a Class 32 Categorical Exemption per the provisions of the California Environmental Quality Act (CEQA) pursuant to Section 15332 of the CEQA Guidelines. MP 16-04, MFADR 14-09, ZV 15-02, MP 14-17, and TRE 14-30 501 N. Santa Anita Avenue April 12, 2016 – Page 10 of 16 For the revised proposal, there are no changes that would create any significant environmental impacts. The proposed project still qualifies as a Class 32 Categorical Exemption for an infill development under the requirements of the California Environmental Quality Act (CEQA) per Section 15332 of the CEQA Guidelines. Refer to Attachment No. 8 for the Preliminary Exemption Assessment. PUBLIC COMMENTS/NOTICE Public hearing notices for this item were mailed on March 31, 2016, to the property owners and tenants of those properties that are located within 300 feet of the subject property – see Figure 6. As of April 8, 2016, staff had not received any comments from the neighboring residents. The architects and property owner met with some of the neighboring property owners and residents on April 7, 2016, to go over the project and hear of any concerns they might have regarding the proposed development. Some of the neighbors were concerned that the proposed project would negatively impact the amount of street parking available and increase congestion in the area since the neighborhood has only one point of ingress and egress from N. Santa Anita Avenue. Concerns were also raised regarding the proposed architectural style (e.g., looks like a dormitory) and potential impacts from the construction activity. RECOMMENDATION It is recommended that the Planning Commission adopt Resolution No. 1961 for approval of Modification No. MP 16-04, revisions to Multiple-Family Architectural Design Review No. MFADR 14-09, and extensions for Zone Variance No. ZV 15-02, Modification No. MP 14-17, and Oak Tree Encroachment Permit No. TRE 14-30, based on the aforementioned findings, including that the project is Categorically Exempt from the California Environmental Quality Act (CEQA), that the proposed right-of-way vacation of portions of Colorado Boulevard is consistent with the City’s General Plan goals and policies so as to recommend approval to the City Council, and subject to the following conditions: 1. The project shall be developed and maintained by the applicant/property owner in a manner that is consistent with the plans submitted and conditionally approved for TTM 14-03 (73106), ZV 15-02, MP 14-17, MP 16-04 as revised to extend the landscaping, TRE 14-30, and MFADR 14-09 as revised, subject to the approval of the Development Services Director or designee, including the stone and stucco color(s). 2. The project shall be developed and maintained by the applicant/property owner in compliance with all of the recommended tree protection measures listed in the Oak Tree Report and Addenda prepared for this project. Figure 6. Notification Area Map MP 16-04, MFADR 14-09, ZV 15-02, MP 14-17, and TRE 14-30 501 N. Santa Anita Avenue April 12, 2016 – Page 11 of 16 3. The applicant/property owner shall be required to pay a $100 Map fee and $25 Final Map Approval fee prior to the approval of the Tract Map. 4. Prior to approval of the Tract Map or issuance of a building permit, the applicant/property owner shall either construct or post security for all public improvements to be shown on the Tentative Map: a. The applicant/property owner shall install new street trees to be shown on the Grading Plan located in the parkways along Santa Anita Avenue and Colorado Boulevard per the City of Arcadia Street Tree Master Plan. b. The applicant/property owner shall construct a new ADA curb ramp at the corner of Santa Anita Avenue and Colorado Boulevard. c. The applicant/property owner shall remove and replace the sidewalk along Santa Anita Avenue from property line to property line. d. The applicant/property owner shall remove and replace the curb and gutter from property line to property line along Colorado Boulevard, Cornell Drive, Windsor Road, and Santa Anita Avenue. e. The applicant/property owner shall construct new driveway approaches per the City of Arcadia standard. f. The applicant/property owner shall construct a new inlet structure and underground piped storm water system to capture and convey the runoff from the alley to the north of the site to outlet at an approved drainage device, subject to the approval of the City Engineer. 5. Prior to the issuance of a building permit or the recordation of the final map, whichever comes first, the applicant/property owner shall make application to the City and pay all fees determined by the City to be necessary to vacate a portion of Colorado Boulevard in conformance with the site plan and the tentative map. The City shall retain a public utility easement over the entire vacated portion of the street. Prior to the City proceeding with the street vacation, the developer shall enter into an agreement in a form and substance approved by the Assistant City Manager/Development Services Director and the City Attorney or their designees, and post security in an amount determined by the Assistant City Manager/Development Services Director or designee, for the construction of a sidewalk, retaining wall, and all associated elements along Colorado Boulevard at the proposed property line. The improvements must be completed in the time required by the Agreement, regardless of the developer’s project proceeding. 6. The applicant/property owner shall submit a Grading Plan prepared by a registered civil engineer subject to the approval of the City Engineer prior to issuance of a building permit. MP 16-04, MFADR 14-09, ZV 15-02, MP 14-17, and TRE 14-30 501 N. Santa Anita Avenue April 12, 2016 – Page 12 of 16 7. The applicant/property owner shall grant the City of Arcadia 5’-0” easements along Santa Anita Avenue and Cornell Drive for Street and Highway Purposes. 8. The applicant/property owner shall grant the City of Arcadia a corner cutback dedication at the corner of Santa Anita Avenue and Colorado Boulevard. The dedication shall be sufficient in size to accommodate a standard ADA curb ramp. 9. Prior to issuance of grading permit, the applicant/property owner shall complete the following: a. Grant Southern California Edison Co. and any other appropriate entities easement(s) for their respective on-site facilities by separate documents. b. Grant the City of Arcadia, easement(s) for Public Utilities for any sewer, water, and/or storm drain facilities, subject to the satisfaction of the City Engineer. c. Provide proof that all affected utility companies have accepted and are satisfied with the new easements and that they approve of the City of Arcadia’s quitclaim of the existing Public Utility Easement. d. Request the City of Arcadia to quitclaim the existing Public Utility Easement either on the Final Map or by a separate document. The quitclaim must be approved prior to issuance of a grading permit. 10. The applicant/property owner shall submit a Standard Urban Stormwater Mitigation Plan (SUSMP) subject to the approval of the City Engineer prior to the issuance of a building permit. 11. Prior to the approval of the Final Map the applicant/property owner shall submit to the City Engineer for approval a separate demolition and erosion control plan prepared by a registered civil engineer, and all existing structures shall be demolished prior to approval of the Final Map. 12. Prior to the issuance of a building permit, the applicant/property owner shall design and relocate the existing sewer main on Cornell Drive and the subject property as necessary to accommodate the proposed development. The design of the affected portions of the sewer main shall include, but not be limited to the relocation of manholes 507MH047 and 507MH049, and the addition of two new manholes and sewer mainline piping. 13. Access to a new manhole on the subject property shall be provided for routine maintenance of the sewer main. The access shall be unrestricted in its height, minimum 12-feet in width, and capable of supporting H20 vehicle loading. 14. Access to manhole 507MH051 shall be provided from Colorado Boulevard. Access shall be a minimum 4’ wide. A gate must be capable of being opened by City personnel with use of a City key, or by providing a lockbox. MP 16-04, MFADR 14-09, ZV 15-02, MP 14-17, and TRE 14-30 501 N. Santa Anita Avenue April 12, 2016 – Page 13 of 16 15. Prior to the issuance of a building permit, the Developer/Owner shall remove and replace the existing 36” x 22” CMP storm drain from Windsor Road to Santa Anita Avenue with a new storm drain capable of conveying a comparable flow volume and flow rate as the existing drain. Design of the replacement drain shall be subject to the approval of the City Engineer. 16. Prior to the issuance of a building permit, the Developer/Owner shall design and construct a new storm drain capable of conveying flow from the alley south of Newman Avenue, between Windsor Road and Santa Anita Avenue to Cornell Drive and then to existing storm drains at either Colorado Boulevard or Santa Anita Avenue. 17. If it is determined by the Fire Marshal that a common fire suppression system (NFPA-13) is required to provide fire protection for the development, the fire service shall be served by a separate fire service with Double Check Detector Assembly (DCDA). 18. The applicant/property owner shall comply with the General Construction NPDES Permit. Submit a Notice of Intent (NOI) and pay applicable fees to the State Water Resources Control Board. 19. The applicant/property owner shall prepare a Storm Water Pollution Prevention Plan (SWPPP) as part of the General Construction Permit requirements. 20. A Waste Discharge Identification (WDID) number shall be issued by the State prior to the approval of any grading plans. 21. The proposed development will require a Standard Urban Stormwater Mitigation Plan (SUSMP) if there will be the creation, addition, or replacement of 5,000 square feet or more of impermeable surface area. The applicant/property owner shall comply with the SUSMP as prescribed by the Los Angeles County Department of Public Works SUSMP Manual and the construction plans shall show the selected measures on the grading plan to the satisfaction of the City Engineer or designee. 22. The applicant/property owner shall integrate low impact development (LID) strategies into the site design. These strategies include using infiltration trenches, bio-retention planter boxes, roof drains connected to a landscaped area, pervious concrete/paver, etc. 23. Condominium or townhouse complexes of more than 5 individual units shall be served by a common domestic water meter and service capable of supplying sufficient water to meet all domestic and fire suppression needs of the total number of units 24. If the water service is to be used to supply both domestic water and fire sprinklers for each unit, the developer shall separate the fire service from the MP 16-04, MFADR 14-09, ZV 15-02, MP 14-17, and TRE 14-30 501 N. Santa Anita Avenue April 12, 2016 – Page 14 of 16 domestic water service at each unit with an approved back flow prevention device. 25. A separate water service and meter will be required for common area landscape irrigation. 26. A Water Meter Clearance Application, filed with the Public Works Services Department, shall be required prior to permit issuance 27. New water service installation shall be by the applicant/property owner. Installation shall be according to the specifications of the Public Works Services Department, Engineering Division. Abandonment of existing water services, if necessary, shall be by the Developer, according to Public Works Services Department, Engineering Division specifications. 28. If any drainage fixture elevation is lower than the elevation of the next upstream manhole cover (514.92), an approved backwater valve is required. 29. Existing trees in parkways shall remain and be protected. 30. The project shall comply with the 2013 California Building Code, including Chapter 11-A (residential accessibility) and with the Arcadia Multi-Family Standards. 31. The applicant/property owner shall install an automatic sprinkler system per the City of Arcadia Fire Department Single & Multiple-Family Dwelling Sprinkler Standard prior to obtaining final occupancy. 32. A fire hydrant shall be provided adjacent to the driveway entrance from Windsor Road. 33. Fire extinguishers of 2A:10BC type shall be provided on the first floor level prior to the issuance of the Certificate of Occupancy. The maximum travel distance to an extinguisher shall be 75 feet. 34. The trash enclosure in the semi-subterranean parking area shall be revised to accommodate the required trash containers to the satisfaction of the Public Works Services Director or designee. 35. The applicant/property owner shall comply with all City requirements regarding building safety, fire prevention, detection, suppression, emergency access, public right-of-way improvements, parking, water supply and water facilities, sewer facilities, trash reduction and recycling requirements, and National Pollutant Discharge Elimination System (NPDES) measures to the satisfaction of the Building Official, Fire Marshal, Public Works Services Director and Development Services Director. Compliance with these requirements is to be determined by having fully detailed construction plans submitted for plan check review and approval by the foregoing City officials and employees. MP 16-04, MFADR 14-09, ZV 15-02, MP 14-17, and TRE 14-30 501 N. Santa Anita Avenue April 12, 2016 – Page 15 of 16 36. The applicant/property owner shall defend, indemnify, and hold harmless the City of Arcadia and its officials, officers, employees, and agents from and against any claim, action, or proceeding against the City of Arcadia, its officials, officers, employees or agents to attack, set aside, void, or annul any approval or conditional approval of the City of Arcadia concerning this project and/or land use decision, including but not limited to any approval or conditional approval of the City Council, Planning Commission, or City Staff, which action is brought within the time period provided for in Government Code Section 66499.37 or other provision of law applicable to this project or decision. The City shall promptly notify the applicant of any claim, action, or proceeding concerning the project and/or land use decision and the City shall cooperate fully in the defense of the matter. The City reserves the right, at its own option, to choose its own attorney to represent the City, its officials, officers, employees, and agents in the defense of the matter. 37. Approval of the revisions to MFADR 14-09, MP 16-04, and the extensions for ZV 15-02, MP 14-17, and TRE 14-30 shall not take effect unless on or before 30 calendar days after the Planning Commission adoption of Resolution No. 1961, the applicant and property owner have executed and filed with the Community Development Administrator or designee an Acceptance Form available from the Development Services Department to indicate awareness and acceptance of these conditions of approval. PLANNING COMMISSION ACTION Approval If the Planning Commission intends to approve this project, the Commission should approve a motion to adopt Resolution No. 1961 to approve Modification No. MP 16-04, the revisions to MFADR 14-09, and the extensions for Zone Variance No. ZV 15-02, Modification No. MP 14-17, and Oak Tree Encroachment Permit No. TRE 14-30, based on the aforementioned findings, including that the project is Categorically Exempt from the California Environmental Quality Act (CEQA), and subject to the aforementioned conditions, or as may be modified by the Commission. Denial If the Planning Commission intends to deny this project, the Commission should state the specific findings that the proposal does not satisfy based on the evidence presented with specific reasons for denial, and approve a motion to deny Modification No. MP 16- 04, the revisions to MFADR 14-09, and/or the extensions for Zone Variance No. ZV 15- 02, Modification No. MP 14-17, and/or Oak Tree Encroachment Permit No. TRE 14-30, and direct staff to prepare a resolution for adoption at the next meeting that incorporates the Commission’s decision and specific findings. If any Planning Commissioner or other interested party has any questions or comments regarding this matter prior to the April 12, 2016, public hearing, please contact Assistant MP 16-04, MFADR 14-09, ZV 15-02, MP 14-17, and TRE 14-30 501 N. Santa Anita Avenue April 12, 2016 – Page 16 of 16 Planner, Jordan Chamberlin by calling (626) 821-4334, or by email to JChamberlin@ArcadiaCA.gov. Approved: Attachment No. 1: Resolution No. 1947 Attachment No. 2: Resolution No. 1961 Attachment No. 3: Aerial Photo and Zoning Information and Photos of the Subject Property and Vicinity Attachment No. 4: Revised Architectural Plans Attachment No. 5: Extension Request Letters Attachment No. 6: Oak Tree Report and Addenda Attachment No. 7: Initial Study dated September 23, 2015 Attachment No. 8: Preliminary Exemption Assessment Attachment No. 1 Attachment No. 1 Resolution No. 1947 Attachment No. 2 Attachment No. 2 Resolution No. 1961 RESOLUTION NO. 1961 A RESOLUTION OF THE PLANNING COMMISSION OF THE CITY OF ARCADIA, CALIFORNIA, APPROVING MODIFICATION APPLICATION NO. MP 16-04, REVISIONS TO PREVIOUSLY APPROVED MULTIPLE- FAMILY ARCHITECTURAL DESIGN REVIEW NO. MFADR 14-09, AND EXTENSION REQUESTS FOR THE PREVIOUSLY APPROVED ZONE VARIANCE NO. ZV 15-02, MODIFICATION APPLICATION NO. MP 14- 17, AND OAK TREE ENCROACHMENT PERMIT NO. TRE 14-30 AS AMENDED, WITH A CATEGORICAL EXEMPTION UNDER THE CALIFORNIA ENVIRONMENTAL QUALITY ACT (CEQA) FOR A 20-UNIT RESIDENTIAL CONDOMINIUM DEVELOPMENT AT 501 N. SANTA ANITA AVENUE WHEREAS, on November 25, 2015, an application was filed by Mr. Jonathan Kelly, for the design review of architectural revisions to the previously approved 20-unit residential condominium development proposed for 501 N. Santa Anita Avenue, Development Services Department Case No. MFADR 14-09; and WHEREAS, on March 11, 2016, an application was filed by Mr. James Li, for Modifications to allow a new wall and fence to exceed 6’-0” in height with a maximum height of 18’-5” and for portions of the wall and fence to be located closer than 18” to the street side property line along Colorado Boulevard at 501 N. Santa Anita Avenue, Development Services Department Case No. MP 16-04; and WHEREAS, on March 11, 2016, extension requests were filed by Mr. Jonathan Kelly, for the previously approved Zone Variance, Modifications, and Oak Tree Encroachment Permit at 501 N. Santa Anita Avenue, Development Services Department Case Nos. ZV 15-02, MP 14-17, and TRE 14-30. The revisions to the Design Review, the new Modification application, and the extension requests for the previously approved applications are hereafter individually and collectively referred to as the “Project”; and 2 WHEREAS, on March 31, 2016, a Preliminary Exemption Assessment for the Project was prepared, and it was determined that the Project is exempt under CEQA, per Section 15332 of the CEQA Guidelines because the Project is considered infill development; and WHEREAS, on April 12, 2015, a duly-noticed public hearing was held before the Planning Commission on the Project, at which time all interested persons were given full opportunity to be heard and to present evidence; and NOW, THEREFORE, THE PLANNING COMMISSION OF THE CITY OF ARCADIA HEREBY RESOLVES AS FOLLOWS: SECTION 1. That the factual data submitted by the Community Development Division in the staff report dated April 12, 2016 are true and correct. SECTION 2. This Commission finds, based upon the entire record: 1. That the proposed subdivision as previously approved, together with the provisions for its design and improvement, is consistent with the City’s General Plan, the City’s Subdivision Regulations, and the State Subdivision Map Act. FACT: The proposed project will replace the church with a new, 20-unit, residential development that is consistent in character with the High Density Multiple- Family Residential designation as described in the City’s General Plan and is to be subdivided into condominiums in a manner that is consistent with the City’s Subdivision Regulations, and the State Subdivision Map Act.. 2. That the discharge of waste from the proposed subdivision into the community sewer system will comply with existing requirements prescribed by a California Regional Water Quality Control Board. 3 FACT: The Arcadia Public Works Services Department confirmed that the proposed development will be adequately served by the existing sewer infrastructure and the requirements of the California Regional Water Quality Control Board will be satisfied. 3. That the proposed Zoning Modifications for the new wall height and setback will secure an appropriate improvement of a lot; prevent an unreasonable hardship; and/or promote uniformity of development. FACT: The requested Modifications will allow the site to be developed in a manner similar to other R-3 zoned properties and will prevent an unreasonable hardship due to the significant grade difference between the subject property and the street and the numerous utilities that are on located on the subject site along Colorado Boulevard. The Modifications will also secure appropriate improvements that will be compatible with the neighboring commercial and residential properties. 4. That the findings for the prior approval of ZV 15-02, MP 14-07, and TRE 14-30 are still valid and the extensions are justifiable. FACT: The original findings for approval of Zone Variance No. ZV 15-02, Zoning Modification No. MP 14-07, and Oak Tree Encroachment Permit No TRE 14-30 remain valid and are still an integral part of the revised proposal. The findings for approval are as follows: a. That there are exceptional or extraordinary circumstances or conditions applicable to the property involved, or to the intended use of the property, that do not apply generally to the property or class of use in the same zone or vicinity. FACT: The irregular shape of the property and the extensive utility easements on it are the bases for approval of a variance from the minimum density requirement. The 4 unique shape and the required easements limit where the residential units may be located. This unique situation is an exceptional circumstance that necessitates a reduction in the number of units so as to allow the development to comply with other essential R-3 Zoning Code requirements, particularly the driveway widths, the number of parking spaces, and the minimum ingress and egress area for each parking space. b. That the granting of such variance will not be materially detrimental to the public health or welfare or injurious to the property or improvements in such zone or vicinity in which the property is located. FACT: A multiple-family development that is not at or in excess of the maximum density on this site would not have these effects. Providing 20 units in lieu of 23 units on the subject property would not be materially detrimental to the other properties in this R- 3 zoned area. Indeed, the reduction in units would be less impactful to the properties in the vicinity of the subject property compared to the minimum 23 units required. c. That such variance is necessary for the preservation and enjoyment of a substantial property right of the applicant possessed by other property in the same zone and vicinity. FACT: This variance is necessary to allow the site to be developed in a manner similar to the other R-3 zoned properties of this area, which do not have irregular lot shapes or such substantial easements that reduce the developable area of a property. d. That the granting of such variance will not adversely affect the comprehensive general plan. FACT: The proposed development, despite the reduction in the number of units will have a density of 16 dwelling units per acre, which is consistent with the General 5 Plan Land Use Designation of High Density Residential that has a density range of 12-30 dwelling units per acre. e. That the proposed Zoning Modification will secure an appropriate improvement of a lot; prevent an unreasonable hardship; and/or promote uniformity of development. FACT: The requested Modifications will allow the site to be developed in a manner similar to other R-3 zoned properties and will prevent an unreasonable hardship due to the irregular shape of the lot, the various easements that must be maintained and therefore cannot be built on, and the change in grade elevation between the site and an adjacent public right-of-way. The Modifications will also secure appropriate improvements that will be compatible with the neighboring commercial and residential properties. 5. That this Project is Categorically Exempt under the California Environmental Quality Act (CEQA) per Section 15332 (Class 32) of the CEQA Guidelines as an infill development. 6. That the partial vacation of the City’s street right-of-way along Colorado Boulevard to gain additional land for the private residential development and provide disabled accessibility onto the subject site from the sidewalk is consistent with the General Plan, and that the Planning Commission recommends approval of the vacation to the City Council. This transaction would occur concurrently with the street vacation and improvements to Colorado Boulevard. The Planning Commission action and determination of the General Plan consistency, is not a project for the purposes of CEQA. The proposed partial vacation of the right-of-way by the City Council is expected to be Categorically Exempt from CEQA pursuant to Section 15301(c) because the action 6 consists of a legal transfer of ownership which will result in negligible or no expansion of use beyond the project analyzed in the General Plan Environmental Impact Report, adopted in 2010. 7. That the Development Services Director or designee is authorized to approve and execute, if necessary, a subdivision agreement for this project. SECTION 3. For the foregoing reasons the Planning Commission determines that the Project is Categorically Exempt per Section 15332 of the CEQA Guidelines, and approves Modification No. MP 16-04, revisions to MFADR 14-09, and extensions for Zone Variance No. ZV 15-02, Modification No. MP 14-17, and Oak Tree Encroachment Permit No. TRE 14-30 as amended, for a 20-unit residential condominium development at 501 N. Santa Anita Avenue, subject to the conditions of approval attached hereto. SECTION 4. The Secretary shall certify to the adoption of this Resolution. Passed, approved and adopted this _____ day of _____________, 2016. Chairman, Planning Commission ATTEST: Secretary APPROVED AS TO FORM: Stephen P. Deitsch City Attorney 7 RESOLUTION NO. 1961 Conditions of Approval 1. The project shall be developed and maintained by the applicant/property owner in a manner that is consistent with the plans submitted and conditionally approved for TTM 14-03 (73106), ZV 15-02, MP 14-17, MP 16-04 as revised to extend the landscaping, TRE 14-30, and MFADR 14-09 as revised, subject to the approval of the Development Services Director or designee, including the stone and stucco color(s). 2. The project shall be developed and maintained by the applicant/property owner in compliance with all of the recommended tree protection measures listed in the Oak Tree Report and Addenda prepared for this project. 3. The applicant/property owner shall be required to pay a $100 Map fee and $25 Final Map Approval fee prior to the approval of the Tract Map. 4. Prior to approval of the Tract Map or issuance of a building permit, the applicant/property owner shall either construct or post security for all public improvements to be shown on the Tentative Map: a. The applicant/property owner shall install new street trees to be shown on the Grading Plan located in the parkways along Santa Anita Avenue and Colorado Boulevard per the City of Arcadia Street Tree Master Plan. b. The applicant/property owner shall construct a new ADA curb ramp at the corner of Santa Anita Avenue and Colorado Boulevard. c. The applicant/property owner shall remove and replace the sidewalk along Santa Anita Avenue from property line to property line. d. The applicant/property owner shall remove and replace the curb and gutter from property line to property line along Colorado Boulevard, Cornell Drive, Windsor Road, and Santa Anita Avenue. e. The applicant/property owner shall construct new driveway approaches per the City of Arcadia standard. f. The applicant/property owner shall construct a new inlet structure and underground piped storm water system to capture and convey the runoff from the alley to the north of the site to outlet at an approved drainage device, subject to the approval of the City Engineer. 5. Prior to the issuance of a building permit or the recordation of the final map, whichever comes first, the applicant/property owner shall make application to the City and pay all fees determined by the City to be necessary to vacate a portion of Colorado Boulevard in conformance with the site plan and the tentative map. The City shall retain a public utility easement over the entire vacated portion of 8 the street. Prior to the City proceeding with the street vacation, the developer shall enter into an agreement in a form and substance approved by the Assistant City Manager/Development Services Director and the City Attorney or their designees, and post security in an amount determined by the Assistant City Manager/Development Services Director or designee, for the construction of a sidewalk, retaining wall, and all associated elements along Colorado Boulevard at the proposed property line. The improvements must be completed in the time required by the Agreement, regardless of the developer’s project proceeding. 6. The applicant/property owner shall submit a Grading Plan prepared by a registered civil engineer subject to the approval of the City Engineer prior to issuance of a building permit. 7. The applicant/property owner shall grant the City of Arcadia 5’-0” easements along Santa Anita Avenue and Cornell Drive for Street and Highway Purposes. 8. The applicant/property owner shall grant the City of Arcadia a corner cutback dedication at the corner of Santa Anita Avenue and Colorado Boulevard. The dedication shall be sufficient in size to accommodate a standard ADA curb ramp. 9. Prior to issuance of grading permit, the applicant/property owner shall complete the following: a. Grant Southern California Edison Co. and any other appropriate entities easement(s) for their respective on-site facilities by separate documents. b. Grant the City of Arcadia, easement(s) for Public Utilities for any sewer, water, and/or storm drain facilities, subject to the satisfaction of the City Engineer. c. Provide proof that all affected utility companies have accepted and are satisfied with the new easements and that they approve of the City of Arcadia’s quitclaim of the existing Public Utility Easement. d. Request the City of Arcadia to quitclaim the existing Public Utility Easement either on the Final Map or by a separate document. The quitclaim must be approved prior to issuance of a grading permit. 10. The applicant/property owner shall submit a Standard Urban Stormwater Mitigation Plan (SUSMP) subject to the approval of the City Engineer prior to the issuance of a building permit. 11. Prior to the approval of the Final Map the applicant/property owner shall submit to the City Engineer for approval a separate demolition and erosion control plan prepared by a registered civil engineer, and all existing structures shall be demolished prior to approval of the Final Map. 9 12. Prior to the issuance of a building permit, the applicant/property owner shall design and relocate the existing sewer main on Cornell Drive and the subject property as necessary to accommodate the proposed development. The design of the affected portions of the sewer main shall include, but not be limited to the relocation of manholes 507MH047 and 507MH049, and the addition of two new manholes and sewer mainline piping. 13. Access to a new manhole on the subject property shall be provided for routine maintenance of the sewer main. The access shall be unrestricted in its height, minimum 12-feet in width, and capable of supporting H20 vehicle loading. 14. Access to manhole 507MH051 shall be provided from Colorado Boulevard. Access shall be a minimum 4’ wide. A gate must be capable of being opened by City personnel with use of a City key, or by providing a lockbox. 15. Prior to the issuance of a building permit, the Developer/Owner shall remove and replace the existing 36” x 22” CMP storm drain from Windsor Road to Santa Anita Avenue with a new storm drain capable of conveying a comparable flow volume and flow rate as the existing drain. Design of the replacement drain shall be subject to the approval of the City Engineer. 16. Prior to the issuance of a building permit, the Developer/Owner shall design and construct a new storm drain capable of conveying flow from the alley south of Newman Avenue, between Windsor Road and Santa Anita Avenue to Cornell Drive and then to existing storm drains at either Colorado Boulevard or Santa Anita Avenue. 17. If it is determined by the Fire Marshal that a common fire suppression system (NFPA-13) is required to provide fire protection for the development, the fire service shall be served by a separate fire service with Double Check Detector Assembly (DCDA). 18. The applicant/property owner shall comply with the General Construction NPDES Permit. Submit a Notice of Intent (NOI) and pay applicable fees to the State Water Resources Control Board. 19. The applicant/property owner shall prepare a Storm Water Pollution Prevention Plan (SWPPP) as part of the General Construction Permit requirements. 20. A Waste Discharge Identification (WDID) number shall be issued by the State prior to the approval of any grading plans. 21. The proposed development will require a Standard Urban Stormwater Mitigation Plan (SUSMP) if there will be the creation, addition, or replacement of 5,000 square feet or more of impermeable surface area. The applicant/property owner shall comply with the SUSMP as prescribed by the Los Angeles County Department of Public Works SUSMP Manual and the construction plans shall 10 show the selected measures on the grading plan to the satisfaction of the City Engineer or designee. 22. The applicant/property owner shall integrate low impact development (LID) strategies into the site design. These strategies include using infiltration trenches, bio-retention planter boxes, roof drains connected to a landscaped area, pervious concrete/paver, etc. 23. Condominium or townhouse complexes of more than 5 individual units shall be served by a common domestic water meter and service capable of supplying sufficient water to meet all domestic and fire suppression needs of the total number of units 24. If the water service is to be used to supply both domestic water and fire sprinklers for each unit, the developer shall separate the fire service from the domestic water service at each unit with an approved back flow prevention device. 25. A separate water service and meter will be required for common area landscape irrigation. 26. A Water Meter Clearance Application, filed with the Public Works Services Department, shall be required prior to permit issuance 27. New water service installation shall be by the applicant/property owner. Installation shall be according to the specifications of the Public Works Services Department, Engineering Division. Abandonment of existing water services, if necessary, shall be by the Developer, according to Public Works Services Department, Engineering Division specifications. 28. If any drainage fixture elevation is lower than the elevation of the next upstream manhole cover (514.92), an approved backwater valve is required. 29. Existing trees in parkways shall remain and be protected. 30. The project shall comply with the 2013 California Building Code, including Chapter 11-A (residential accessibility) and with the Arcadia Multi-Family Standards. 31. The applicant/property owner shall install an automatic sprinkler system per the City of Arcadia Fire Department Single & Multiple-Family Dwelling Sprinkler Standard prior to obtaining final occupancy. 32. A fire hydrant shall be provided adjacent to the driveway entrance from Windsor Road. 33. Fire extinguishers of 2A:10BC type shall be provided on the first floor level prior to the issuance of the Certificate of Occupancy. The maximum travel distance to an extinguisher shall be 75 feet. 11 34. The trash enclosure in the semi-subterranean parking area shall be revised to accommodate the required trash containers to the satisfaction of the Public Works Services Director or designee. 35. The applicant/property owner shall comply with all City requirements regarding building safety, fire prevention, detection, suppression, emergency access, public right-of-way improvements, parking, water supply and water facilities, sewer facilities, trash reduction and recycling requirements, and National Pollutant Discharge Elimination System (NPDES) measures to the satisfaction of the Building Official, Fire Marshal, Public Works Services Director and Development Services Director. Compliance with these requirements is to be determined by having fully detailed construction plans submitted for plan check review and approval by the foregoing City officials and employees. 36. The applicant/property owner shall defend, indemnify, and hold harmless the City of Arcadia and its officials, officers, employees, and agents from and against any claim, action, or proceeding against the City of Arcadia, its officials, officers, employees or agents to attack, set aside, void, or annul any approval or conditional approval of the City of Arcadia concerning this project and/or land use decision, including but not limited to any approval or conditional approval of the City Council, Planning Commission, or City Staff, which action is brought within the time period provided for in Government Code Section 66499.37 or other provision of law applicable to this project or decision. The City shall promptly notify the applicant of any claim, action, or proceeding concerning the project and/or land use decision and the City shall cooperate fully in the defense of the matter. The City reserves the right, at its own option, to choose its own attorney to represent the City, its officials, officers, employees, and agents in the defense of the matter. 37. Approval of the revisions to MFADR 14-09, MP 16-04, and the extensions for ZV 15-02, MP 14-17, and TRE 14-30 shall not take effect unless on or before 30 calendar days after the Planning Commission adoption of Resolution No. 1961, the applicant and property owner have executed and filed with the Community Development Administrator or designee an Acceptance Form available from the Development Services Department to indicate awareness and acceptance of these conditions of approval. - - - Attachment No. 3 Attachment No. 3 Aerial Photo and Zoning Information and Photos of the Subject Property and Vicinity Photo of subject property, 501 N. Santa Anita Avenue, from onsite, adjacent to N. Santa Anita Avenue. Photo of subject property, 501 N. Santa Anita Avenue, from N. Santa Anita Avenue. View of the back half of the subject property to be quitclaimed. Photo taken from onsite. View of the back half of the subject property, to be quitclaimed. Photo taken from the corner of Windsor Road and Cornell Drive. Photo of subject property, 501 N. Santa Anita Avenue, from Colorado Boulevard. Photo of concrete slope along Colorado Boulevard adjacent to the subject property. Photo of adjacent property to the northwest, 520 Cornell Drive. Photo of adjacent property to the north, 515 Windsor Road. Photo of adjacent property to the north, 514 Windsor Road. Photo of adjacent property to the north, 513 N. Santa Anita Avenue Road. Photo of adjacent property to the northeast, 510 N. Santa Anita Avenue. Photo of adjacent property to the east, a Chevron Gas Station, at 500 N. Santa Anita Avenue. Photo of adjacent property to the southeast, an In-N-Out Burger, at 420 N. Santa Anita Boulevard. Photo of adjacent commercial property to the south which includes Fasching's Car Wash, at 425 N. Santa Anita Avenue. Photo of adjacent rail right-of-way to the east. Photo of adjacent park, Newcastle Park to the east beyond the rail right-of-way , at 143 W. Colorado Boulevard. Attachment No. 4 Attachment No. 4 Revised Architectural Plans CORNELL DRIVE WINDSOR ROAD COLORADO BOULEVARD SANTA ANITA AVENUE BUILDING A BUILDING B BUILDING F BUILDING CBUILDING D BUILDING E 1 2 5 3 4 UNUSABLE LANDLOT BLOT A #= Setbacks (see Zoning Summary) Javier GonzalezNo. Cxxxxx Exp. x-xx-17 Robert G. TylerNo. C18812 Exp. 8-31-17 Date Reviewed Drawn ByDescription Do not scale drawings. Contractor shall verifyand be responsible for all dimensions andconditions on the site and Tyler Gonzalez Architects, Inc. shall be notified immediately ofany variations from the dimensions and conditions indicated on these drawings. Drawings, specifications, and other documents,including those in electronic form, prepared by the Architect and the Architect's consultants areInstruments of Service for use solely with respect to this Project. The Architect and theArchitect's consultants shall be deemed theauthors and owners of their respective Instruments of Service and shall retain all common law, statutory and other reserved rights, including copyrights. Visual contact withthese documents constitute prima faciaacceptance of these conditions.Architect of RecordIssue Dates Use of Architect's Drawings2015 Tyler Gonzalez Architects, Inc. c Sheet No.Project No.Scale 139 South Hudson Ave., Suite 300Pasadena, CA 91101626.396.9599 www.TGArchitects.net 1" = 50'-0" G-0.0 Checker Author 2015-09-3015-13 COVERSHEET501 N. Santa Anita Ave. Arcadia, CA 91006 SANTA ANITA CONDOMINIUMS PROJECTSITE PROJECTSITE VICINITY MAP(not to scale)LOCATOR MAP(not to scale)SHEET INDEXSheet Index Sheet Number Sheet Name 0-GENERALG-0.0COVERSHEETG-0.2SURVEYT-1Tentative TractT-2Tentative TractT-3Tentative Tract2-ARCHITECTURALA-0.0EASEMENT PLANA-0.1CONTEXT ELEVATIONSA-1.0SITE PLANSA-1.1SITE PLANSA-1.3SITE DETAILSA-1.4SITE DETAILSA-1.5PERSPECTIVESA-1.6PERSPECTIVESA-1.7PERSPECTIVESA-2.0.AFLOOR PLANS - BUILDING AA-2.0.BFLOOR PLANS - BUILDING AA-2.1FLOOR PLANS - BUILDING BA-2.2.AFLOOR PLANS - BUILDING CA-2.2.BFLOOR PLANS - BUILDING CA-2.3.AFLOOR PLANS - BUILDING DA-2.3.BFOOR PLANS - BUILDING DA-2.4.AFLOOR PLANS - BUILDING EA-2.4.BFLOOR PLANS - BUILDING EA-2.5.AFLOOR PLANS - BUILDING FA-2.5.BFLOOR PLANS - BUILDING FA-2.5.CFLOOR PLANS - BUILDING FA-2.5.DFLOOR PLANS - BUILDING FA-3.0STREET ELEVATIONSA-3.1STREET ELEVATIONSA-3.2.AELEVATIONS - BUILDING AA-3.2.BELEVATIONS - BUILDING AA-3.3ELEVATIONS - BUILDING BA-3.4.AELEVATIONS - BUILDING CA-3.4.BELEVATIONS - BUILDING CA-3.5.AELEVATIONS - BUILDING DA-3.5.BELEVATIONS - BUILDING DA-3.6.AELEVATIONS - BUILDING EA-3.6.BELEVATIONS - BUILDING EA-3.7.AELEVATIONS - BUILDING FA-3.7.BELEVATIONS - BUILDING FA-3.7.CELEVATIONS - BUILDING FA-4.0SECTIONSA-4.1SECTIONSA-4.2SECTIONSA-8.0WINDOW & DOOR SCHEDULES& TYPES7-LANDSCAPEL-1.0PLANTING PLAN 1 3 2.5 1512 2 2 3 2.5 1558 2 3 3 2.5 1870 2 4 3 2.5 1723 2 5 3 2.5 1857 2 6 3 2.5 1860 2 7 3 2.5 1765 2 8 3 2.5 1869 2 9 3 2.5 1849 2 10 3 2.5 1817 2 11 3 2.5 1846 2 12 3 2.5 1857 2 13 4 3 2136 2 14 3 2.5 1972 2 15 3 2.5 1869 2 16 3 2.5 1953 2 17 3 2.5 1983 2 18 3 2.5 1880 2 19 3 2.5 1957 2 20 5 3.5 2304 2 Unit Bed Bath GSF Parking 20 63 37,437 40 ZONING SUMMARY PROPOSED UNIT MATRIX SANTA ANITA CONDOMINIUMS501 NORTH SANTA ANITA AVENUEARCADIA, CALIFORNIA 91006 PROPOSED SITE DIAGRAM Scale 1" = 50'-0" PROJECT TEAM GENERAL NOTESBUILDING CODE SUMMARY Owner:DC Santa Anita Holdings, LLC1005 East Las Tunas Drive., #125San Gabriel, CA 91776Contact: James LiPhone: 626.292.2559Email: 9999jl@gmail.comArchitect:Tyler Gonzalez Architects139 South Hudson Street, Suite 300Pasadena, CA 91101Contact: Rob TylerPhone: 626.396.9599Email: Rob@TGArchitects.netLandscape Architect:Tyler Gonzalez Architects139 South Hudson Street, Suite 300Pasadena, CA 91101Contact: Robert MartinPhone: 626.396.9599Email: RMartin@TGArchitects.netCivil:EGL11819 Coldring Road, Unit AArcadia, CA 91006Contact: Hank JongPhone: 626.263.3588Email: Hank@EGL88.com Applicable Building Codes: 2013 California Building Code2013 Green Building Code2013 California Mechanical Code2013 California Plumbing Code2013 California Electrical Code2013 Title 242013 California Energy Standards Occupancy: R-3 Residential (6 Buildings) Type of Construction: Type V-B, Automatic Sprinkler System Throughout All work shall conform to the governing codes, documents and agencies having jurisdiction over the project. The governing code is the 2013 California Building Codes; CBC, CMC, CPC, CEC, as amended by the City Ordinance and the 2013 Title 24 Energy Standards.Contractor shall obtain and pay for all necessary permits from all agencies having jurisdiction over the work, except only gene ral building permit. Verify all conditions and dimensions at the job site.Deviations fr om the Contract Documents shall be reported to the Architect before proceeding with the work. Commencement of work shall be construed as acceptance of all conditions, dimensions, and substrates.All dimensions are face of stud or sheathing and centerline of columns unless noted otherwise.Drawings are not to be scaled; use written dimensions only.Report dimensional discrepancies to the Architect before proceeding with the work. Maintain a complete set of drawings and specifications on the job site at all times, including copies of all the Architect's su pplemental instructions, construction change authorizations, reviewed shop drawings and project submittals.Provide construction barriers to conform with the requirements of Local and County agencies.All finish grades shall slope away from the building at 2% minimum.Building address numbers to be provided on the front of the buildings, and shall be visible and legible from the street frontin g the property; said numbers shall contrast with their background and must be at least 2" in height and 2" in width.Fire blocking shall be installed per: CBC 708.2.1.Storage of construction ma terials in the public right-of-way is NOT PERMITTED. Specify on site the proposed location of the storage of construction materials. NOTE: In times of high fire hazard in brush areas, temporary fire protection of the construction materials may be r equired. Separate permit required for perimeter retaining walls. 1.2.3.4.5.6.7.8.9.10.11.12.FIRE DEPARMENT NOTESBuildings shall be fully sprinklered per City of Arcadia Fire Department Multi-Family Dwelling Sprinkler Standards.The Fire Lane shall be marked with red curbing and signage. Signage beyond the fire lane shall be provided shwowing the weight capacity of the driveway.Minimum 2A: 10BC fire extinguishers shall be provided showing on the exterior. Max. travel distance from an y unit to an extinguisher shall be 75 feet. 1.2.3. Assessor's Parcel Number: 5775-027-027 Zoning: High Density Multiple Family Residential (R-3) Existing Buildings to be Removed: 501 N Santa Anita Avenue - 1 Building / Built 1956 Proposed: 6 New Buildings2 Stories over 1 Level Subterranean Garage Lot Data:Lot AExisting 35,982 SF After Gains & Losses 39,253 SF Without Unusable Land 38,818 SF Lot BExisting 9,842 SF After Gains & Losses 12,209 SF Without Unusable Land 11,633 SF TotalExisting 45,824 SF (approx. 1.05 acre) After Gains & Losses 51,462 SF (approx. 1.18 acre) Without Unusable Land 49,529 SF (approx. 1.14 acre)Density (After Gains & Losses): Density (After G&L, Without Unusable Land): Minimum Required* 23.0 Minimum Required* 21.0 Lot A (39,253 SF) 17.0 Lot A (38,818 SF) 17.0 Lot B (12,209 SF) 6.0 Lot B (11,633 SF) 4.0 Maximum Allowed** 35.4 Maximum Allowed** 33.0 Lot A (39,253 SF) 27.0 Lot A (38,818 SF) 26.0 Lot B (12,209 SF) 8.4 Lot B (11,633 SF) 7.0 *Dwelling/Acre(1 Unit/2,200 SF of Lot Area)**Dwelling/Acre (1 Unit/1,450 SF of Lot Area)Proposed 20.0 Units F.A.R.: 0.76 (37,437 GSF Building Area over 49,529 SF) Setbacks:Location Min. Req. Provided 1. Rear Yard (Rail Row) 10'-0" 10'-1" Min. 2. North Side Yard 10'-0" 10'-5" Min. 3. South Side Yard (Colorado Blvd.) 25'-0" 10'-1" Min. 4. North Side Yard (Cornell Drive) 10'-0" 10'-1" Min. 5. Front Yard (Santa Anita Ave.) 25'-0" 15'-0" Min. Height Limit:Maximum Allowed 30'-0" Proposed 29'-6" (Measured from First Story to ave. height of pitched roof) Parking:Minimum Required 50 Stalls 2 Stalls/Unit 40 Stalls 1 Guest/2 Units 10 Stalls Provided 50 Stalls Garage 40 Stalls Guest 10 Stalls Open Space Coverage:Minimum Required 2,000 SF Private 2,000 SF (100 SF/Unit) Shared N/A ProvidedPrivate >2,000 SF (see 1/A-1.0) Shared N/A No.DescriptionDate Javier GonzalezNo. Cxxxxx Exp. x-xx-17 Robert G. TylerNo. C18812 Exp. 8-31-17 Date Reviewed Drawn ByDescription Do not scale drawings. Contractor shall verifyand be responsible for all dimensions andconditions on the site and Tyler Gonzalez Architects, Inc. shall be notified immediately ofany variations from the dimensions and conditions indicated on these drawings. Drawings, specifications, and other documents,including those in electronic form, prepared by the Architect and the Architect's consultants areInstruments of Service for use solely with respect to this Project. The Architect and theArchitect's consultants shall be deemed theauthors and owners of their respective Instruments of Service and shall retain all common law, statutory and other reserved rights, including copyrights. Visual contact withthese documents constitute prima faciaacceptance of these conditions.Architect of RecordIssue Dates Use of Architect's Drawings2015 Tyler Gonzalez Architects, Inc. c Sheet No.Project No.Scale 139 South Hudson Ave., Suite 300Pasadena, CA 91101626.396.9599 www.TGArchitects.netG-0.2 Checker Author 2015-09-3015-13 SURVEY501 N. Santa Anita Ave. Arcadia, CA 91006 SANTA ANITA CONDOMINIUMS No.DescriptionDate G G G G G G G G G G G G G G G G G G G G G G G DN  R O Exp.OI N P D N G E HA RE AT ST H S TS K I R E E  AN IO S E F S N 45846 O ERE GN 12/31/16F O R N I A L I F CA CIVIL A N GI NJ E LI G - L 20-UNIT CONDOMINIUM501 N. SANTA ANITA AVE. ARCADIA, CA 91006  SANTA ANITA ARCADIA, LLC9674 TELSTAR AVE., #C,EL MONTE, CA 91731PH: 626-255-7439 APN: 5775-027-027G     G G G G G G G G G G G G G G G G G      R O Exp.OI N P D N G E HA RE AT ST H S TS K I R E E  AN IO S E F S N 45846 O ERE GN 12/31/16F O R N I A L I F CA CIVIL A N GI NJ E LI G - L 20-UNIT CONDOMINIUM501 N. SANTA ANITA AVE. ARCADIA, CA 91006  SANTA ANITA ARCADIA, LLC9674 TELSTAR AVE., #C,EL MONTE, CA 91731PH: 626-255-7439 APN: 5775-027-027G    G G G G G G G G G G G G G G G G G G G G G G G DN  R O Exp.OI N P D N G E HA RE AT ST H S TS K I R E E  AN IO S E F S N 45846 O ERE GN 12/31/16F O R N I A L I F CA CIVIL A N GI NJ E LI G - L 20-UNIT CONDOMINIUM501 N. SANTA ANITA AVE. ARCADIA, CA 91006  SANTA ANITA ARCADIA, LLC9674 TELSTAR AVE., #C,EL MONTE, CA 91731PH: 626-255-7439 APN: 5775-027-027 DN DN DN DN DN 4 5 KL 3 1 6 7 13 22 21 18 17 14 23 GF H E 15 J A 10'-0" x 10'-0"Open Space Requirement 10'-0" x 10'-0"Open Space Requirement 10'-0" x 10'-0"Open Space Requirement 10'-0" x 10'-0"Open Space Requirement 10'-0" x 10'-0"Open Space Requirement 10'-0" x 10'-0"Open Space Requirement 10'-0" x 10'-0"Open Space Requirement 10'-0" x 10'-0"Open Space Requirement 10'-0" x 10'-0"Open Space Requirement 10'-0" x 10'-0"Open Space Requirement 10'-0" x 10'-0"Open Space Requirement 10'-0" x 10'-0"Open Space Requirement 10'-0" x 10'-0"Open Space Requirement 10'-0" x 10'-0"Open Space Requirement10'-0" x 10'-0"Open Space Requirement UNIT 1UNIT 2BUILDING A UNIT 3BUILDING B PROPERTY LINE PR OP ERT YLIN E PROPERTY LINE PROPERTY LINE PROPERTY LINE PROPER TY LINE PROPERTY LINE CORNELL DRIVE WINDSOR ROAD 7.50% SLOPE7.50% SLOPE15.00% SLOPE UNIT 4UNIT 5BUILDING C UNIT 6 UNIT 7UNIT 8UNIT 9 UNIT 19UNIT 18 BUILDING FUNIT 17UNIT 16UNIT 15UNIT 14 UNIT 20 UNIT 10BUILDING EUNIT 11UNIT 12UNIT 13 COLORADO BOULEVARD SANTA ANITA AVENUE 5'-0" EASEMENT FOR STREET & HIGHWAY PURPOSES 10'-0" STORM DRAIN EASEMENT 10'-0" STORM DRAIN EASEMENT 10'-0" SCE POWER POLE EASEMENT SEWER EASEMENT 10'-0" STORM DRAIN EASEMENT SEWER EASEMENT 10'-0" EASEMENT FOR SCE POWER POLES 10'-0"EA SE ME NT FO RS CE PO WE R PO LE S 5'-0" STREET/HIGHWAY EASEMENT 10'-0" x 10'-0"Open Space Requirement PROTECTED TREESTO REMAIN PROTECTED TREETO REMAIN BUILDING D 38' - 1" 52' - 9" 20' - 7" 79' - 6" 49' - 8" 44' - 0" 93' - 7" 73' - 2" 21' - 6" 35' - 10" 35' - 2" 53' - 10" 165' - 0" 49' - 3" 44' - 0" 10'-0" x 10'-0"Open Space Requirement 8.33% SLOPE 4.99% SLOPE 37' - 5" 36' - 1"26' - 0"36' - 1" PROTECTED TREETO REMAIN PROPOSED PUBLIC UTILITY EASEMENT L O T A R E A L O S T M 10'-0" x 10'-0"Open Space Requirement 10'-0" x 10'-0"Open Space Requirement 10'-0" x 10'-0"Open Space Requirement 35' - 4" Javier GonzalezNo. Cxxxxx Exp. x-xx-17 Robert G. TylerNo. C18812 Exp. 8-31-17 Date Reviewed Drawn ByDescription Do not scale drawings. Contractor shall verifyand be responsible for all dimensions andconditions on the site and Tyler Gonzalez Architects, Inc. shall be notified immediately ofany variations from the dimensions and conditions indicated on these drawings. Drawings, specifications, and other documents,including those in electronic form, prepared by the Architect and the Architect's consultants areInstruments of Service for use solely with respect to this Project. The Architect and theArchitect's consultants shall be deemed theauthors and owners of their respective Instruments of Service and shall retain all common law, statutory and other reserved rights, including copyrights. Visual contact withthese documents constitute prima faciaacceptance of these conditions.Architect of RecordIssue Dates Use of Architect's Drawings2015 Tyler Gonzalez Architects, Inc. c Sheet No.Project No.Scale 139 South Hudson Ave., Suite 300Pasadena, CA 91101626.396.9599 www.TGArchitects.net 1/16" = 1'-0" A-0.0 Checker Author 2015-09-3015-13EASEMENT PLAN501 N. Santa Anita Ave. Arcadia, CA 91006 SANTA ANITA CONDOMINIUMS 1/16" = 1'-0" 1 Easement Plan No.DescriptionDate AB CDF E KEY PLAN Colorado Blvd. Santa Anita Blvd. Javier GonzalezNo. Cxxxxx Exp. x-xx-17 Robert G. TylerNo. C18812 Exp. 8-31-17 Date Reviewed Drawn ByDescription Do not scale drawings. Contractor shall verifyand be responsible for all dimensions andconditions on the site and Tyler Gonzalez Architects, Inc. shall be notified immediately ofany variations from the dimensions and conditions indicated on these drawings. Drawings, specifications, and other documents,including those in electronic form, prepared by the Architect and the Architect's consultants areInstruments of Service for use solely with respect to this Project. The Architect and theArchitect's consultants shall be deemed theauthors and owners of their respective Instruments of Service and shall retain all common law, statutory and other reserved rights, including copyrights. Visual contact withthese documents constitute prima faciaacceptance of these conditions.Architect of RecordIssue Dates Use of Architect's Drawings2015 Tyler Gonzalez Architects, Inc. c Sheet No.Project No.Scale 139 South Hudson Ave., Suite 300Pasadena, CA 91101626.396.9599 www.TGArchitects.net 1" = 200'-0" A-0.1 Checker Author 2015-09-3015-13CONTEXT ELEVATIONS501 N. Santa Anita Ave. Arcadia, CA 91006 SANTA ANITA CONDOMINIUMS No.DescriptionDate1/8" = 1'-0" 3. North/South Context Elevation along Windsor Road 2. North/South Context Elevation along Santa Anita Avenue1B. East/West Context Elevation along Colorado Blvd.1A. East/West Context Elevation along Colorado Blvd. Colorado Blvd. Newman Ave. Newman Ave. Colorado Blvd. Santa Anita Avenue Gold Line Railway MATCHLINE MATCHLINE 1A 1B 2 3 Plans gathered via Google Maps aligned to a 1/8" = 1'-0" scaledsite. Elevations gathered via images from Google Street View andaligned to scaled Google Maps. Typical heights (doors, windows,floor-to-floor heights) were used to doublecheck heights of contextelevations. Context Information: DN DN DN DN DN UP A-3.01 4 5 KL 3 1 6 7 13 22 21 18 17 14 23 GF H E A-3.1 1 4 A-3.1 10'-0" x 10'-0"Open Space Requirement 10'-0" x 10'-0"Open Space Requirement 10'-0" x 10'-0"Open Space Requirement 10'-0" x 10'-0"Open Space Requirement 10'-0" x 10'-0"Open Space Requirement 10'-0" x 10'-0"Open Space Requirement 10'-0" x 10'-0"Open Space Requirement 10'-0" x 10'-0"Open Space Requirement 10'-0" x 10'-0"Open Space Requirement 10'-0" x 10'-0"Open Space Requirement 10'-0" x 10'-0"Open Space Requirement 10'-0" x 10'-0"Open Space Requirement 10'-0" x 10'-0"Open Space Requirement 10'-0" x 10'-0"Open Space Requirement 10'-0" x 10'-0"Open Space Requirement 10'-0" x 10'-0"Open Space Requirement 10'-0" x 10'-0"Open Space Requirement10'-0" x 10'-0"Open Space Requirement 505.50 509.00 509.50 UNIT 1UNIT 2BUILDING A UNIT 3BUILDING B PROPERTY LINE PR OP ERT YLIN E PROPERTY LINE PROPERTY LINE PROPERTY LINE PROPERTY LINE PROPER TY LINE PROPERTY LINE CORNELL DRIVE WINDSOR ROAD 7.50% SLOPE7.50% SLOPE15.00% SLOPE UNIT 4UNIT 5BUILDING C UNIT 6 UNIT 7UNIT 8UNIT 9 UNIT 19UNIT 18 BUILDING FUNIT 17UNIT 16UNIT 15UNIT 14 UNIT 20 UNIT 10BUILDING EUNIT 11UNIT 12UNIT 13 COLORADO BOULEVARD SANTA ANITA AVENUE 5'-0" EASEMENT FOR STREET & HIGHWAY PURPOSES 10'-0" STORM DRAIN EASEMENT 10'-0" STORM DRAIN EASEMENT 10'-0" SCE POWER POLE EASEMENT SEWER EASEMENT 10'-0" STORM DRAIN EASEMENT SEWER EASEMENT 10'-0" EASEMENT FOR SCE POWER POLES 10'-0"EAS EME NT FO R SC EP OW ER PO LES 5'-0" STREET/HIGHWAY EASEMENT 10'-0" x 10'-0"Open Space Requirement 15 J PROTECTED TREESTO REMAINPROTECTED TREETO REMAIN BUILDING D 506.50 505.50 505.50 A-3.034 A-3.02 A-3.1 5 A-2.0.A1 2 A-3.1 3 A-2.5.C2 A-2.5.A2 A-2.2.A2 A-2.3.A2 A-2.4.A2 SETBACK25' - 7" 38' - 1" 52' - 9" 20' - 7" 79' - 6" 49' - 8" 44' - 0" SETBACK15' - 0" SETBACK 14 '-8 "93'-7 " SETBACK 10'-2" 73' - 2" 21' - 6" 35' - 10" 35' - 2" 53' - 10" 165' - 0" 49' - 3" 44' - 0" 10'-0" x 10'-0"Open Space Requirement (N) 6'-0" CMU WALL (N) 3'-0" METAL FENCE 8.33% SLOPE 4.99% SLOPE (N) 6'-0" METAL FENCE 5'-0"12'-11"1'-8"35'-4"5" SETBACK 10'-4" SETBACK 10'-1"36'-1"26'-0"36'-1" SETBACK 10'-2" A-1.310 A-1.33 A-2.11 A A 497.25 (N) 6'-0" METAL FENCE(N) 12'-6" RETAINING WALL (N) PLANTING (N) PLANTING (N) 8'-0" RETAINING WALL 6 A-3.1 PROTECTED TREETO REMAIN (E) RETAINING WALLTO BE REMOVED (N) VEHICULAR GATE A-1.33 A-1.33 CATCH BASIN CATCH BASIN BACKFLOW DEVICECLUSTER MAILBOX (N) 6'-0" METAL FENCE (N) ELECTRICAL VAULT M 35'-4" SETBACK 15' - 1" 510.92 510.50 510.92 509.83 509.50 509.83 509.50 A/C A/C A/C W/H W/H W/H W/H W/H TRASH ENCLOSURE A-1.32 TRASH ENCLOSUREACCESSIBLE PATHOF TRAVEL S E T B A C K 10'-1" 508.33 8.33% SLOPE PROPOSED PUBLIC UTILITY EASEMENT (N) SIDEWALK (N) 6'-0" METAL FENCE (N) 6'-0" METAL FENCE 508.33 A-1.311 (N) PEDESTRIAN GATE (N) PEDESTRIAN GATE 7 13 22 21 18 17 23 GF H E CORNELL DRIVE WINDSOR ROAD 505.50 505.50 7.50% SLOPE 15.00% SLOPE COLORADO BOULEVARD SANTA ANITA AVENUE UNIT 1UNIT 2BUILDING A UNIT 3 BUILDING B UNIT 4UNIT 5UNIT 6UNIT 7UNIT 8BUILDING D UNIT 9 UNIT 19UNIT 18 BUILDING FUNIT 17UNIT 16UNIT 15UNIT 14 UNIT 20 UNIT 10 BUILDING EUNIT 11UNIT 12UNIT 13 SHARED DRIVEWAY PROPERTY LINE PR OP ERT YLIN E PROPERTY LINE PROPERTY LINE PROPERTY LINE PROPERTY LINE PROPER TY LINE PROPERTY LINE 15 BUILDING C A-2.2.A1 A-2.3.A1 A-2.4.A1 A-2.5.C1 A-2.5.A1 52' - 9" 20' - 7" 79' - 6" 49' - 8" 44' - 0" 165' - 0" 49' - 3" 44' - 0" 17'-11" 36'-1 "26'-0 "36'-1 " A-1.310 TRASH ENCLOSUREACCESSIBLE PATHOF TRAVEL A-1.33 A A 497.25 (N) 12'-6" RETAINING WALL (N) PLANTING(N) 5'-0" WIDENED SIDEWALK(E) RETAINING WALLTO BE REMOVED (N) PLANTING (N) 8'-0" RETAINING WALL PROTECTED TREETO REMAIN (N) PLANTING CATCH BASIN CATCH BASIN CATCH BASINCATCH BASIN ELEC/GASMETERS ELEC/GASMETERS SETBACK 15' - 1" SETBACK 14'-8 "93'-7" SETBACK 10'-2 " A/C A/C W/H W/H A/C A/C A/C A/C W/H W/H W/H W/H A/C A/C A/C A/C A/C W/H (N) PLANTING S E T B A C K 10'-1" A-1.33 A-1.33 W/H W/H W/H W/H W/H W/HW/HW/H PLAN KEYNOTES3" x 4" Pre-finished Metal Downspout Drain into Planter, Typical4" Internal Roof Drain & Overflow DrainDrain into Planter Robert G. TylerNo. C18812 Exp. 8-31-17 Date Reviewed Drawn ByDescription Do not scale drawings. Contractor shall verifyand be responsible for all dimensions andconditions on the site and Tyler Gonzalez Architects, Inc. shall be notified immediately ofany variations from the dimensions and conditions indicated on these drawings. Drawings, specifications, and other documents,including those in electronic form, prepared by the Architect and the Architect's consultants areInstruments of Service for use solely with respect to this Project. The Architect and theArchitect's consultants shall be deemed theauthors and owners of their respective Instruments of Service and shall retain all common law, statutory and other reserved rights, including copyrights. Visual contact withthese documents constitute prima faciaacceptance of these conditions.Architect of RecordIssue Dates Use of Architect's Drawings2015 Tyler Gonzalez Architects, Inc. c Sheet No.Project No.Scale 139 South Hudson Ave., Suite 300Pasadena, CA 91101626.396.9599 www.TGArchitects.netAs indicated A-1.0 RT JK 2015-09-3015-13 SITE PLANS501 N. Santa Anita Ave. Arcadia, CA 91006 SANTA ANITA CONDOMINIUMS 1/16" = 1'-0" 1 First Floor Plan - Site 1/16" = 1'-0" 2 Garage Floor Plan - Site N No.DescriptionDate A-3.01 4 5 KL 3 1 6 7 13 22 21 18 17 14 23 GF H E A-3.1 1 4 A-3.1 15 J A-3.034 A-3.02 A-3.1 5 2 A-3.1 3 UNIT 1 UNIT 2 BUILDING A UNIT 3BUILDING B UNIT 4 UNIT 5 BUILDING C UNIT 6 UNIT 7UNIT 8UNIT 9 UNIT 19 UNIT 18 BUILDING F UNIT 17UNIT 16UNIT 15 UNIT 14 UNIT 20 UNIT 10 BUILDING E UNIT 11UNIT 12UNIT 13 BUILDING D A-2.2.B1 A-2.4.B1 A-2.5.D1 A-2.0.B1 A-2.5.B1 A-2.3.B1 SETBACK25' - 7" 38' - 1" 52' - 9" 20' - 7" 79' - 6" 49' - 8" 44' - 0" SETBACK15' - 0" SETBACK 14'-8 "93'-7" SETBACK 10'-2 " 73' - 2" 21' - 6" 35' - 10" 35' - 2" 53' - 10" 165' - 0" 49' - 3" 44' - 0" SETBAC K 17'-11"37'-5" SETBAC K 10'-0" SETBACK 19'-6"35'-4" SETBAC K 10'-6" SETBACK 10'-1"36'-1"26'-0"36'-1" SETBACK 10'-2" A-2.12 A 6 A-3.1 M SETBACK 15' - 1" A/C - - 4 5 KL 3 1 6 7 13 22 21 18 17 14 23 GF H E 15 J UNIT 1UNIT 2BUILDING A UNIT 3 BUILDING B UNIT 4UNIT 5BUILDING C UNIT 6 UNIT 7UNIT 8UNIT 9 UNIT 19UNIT 18 BUILDING FUNIT 17UNIT 16UNIT 15UNIT 14 UNIT 20 UNIT 10BUILDING EUNIT 11UNIT 12 UNIT 13 BUILDING D A-2.2.B2 A-2.3.B2 A-2.4.B2 A-2.5.D2 A-2.0.B2 A-2.5.B2 38' - 1" 52' - 9" 20' - 7" 79' - 6" 49' - 8" 44' - 0" 93'-7"10 '-2 " 73' - 2" 21' - 6" 35' - 10" 35' - 2" 53' - 10" 165' - 0" 49' - 3" 44' - 0" 37'-5" 35'-4" 36'-1"26'-0"36'-1"10'-2" A-2.13 A M A/C A/CA/CA/CA/C ---- - - PLAN KEYNOTES3" x 4" Pre-finished Metal Downspout Drain into Planter, Typical4" Internal Roof Drain & Overflow DrainDrain into Planter Javier GonzalezNo. Cxxxxx Exp. x-xx-17 Robert G. TylerNo. C18812 Exp. 8-31-17 Date Reviewed Drawn ByDescription Do not scale drawings. Contractor shall verifyand be responsible for all dimensions andconditions on the site and Tyler Gonzalez Architects, Inc. shall be notified immediately ofany variations from the dimensions and conditions indicated on these drawings. Drawings, specifications, and other documents,including those in electronic form, prepared by the Architect and the Architect's consultants areInstruments of Service for use solely with respect to this Project. The Architect and theArchitect's consultants shall be deemed theauthors and owners of their respective Instruments of Service and shall retain all common law, statutory and other reserved rights, including copyrights. Visual contact withthese documents constitute prima faciaacceptance of these conditions.Architect of RecordIssue Dates Use of Architect's Drawings2015 Tyler Gonzalez Architects, Inc. c Sheet No.Project No.Scale 139 South Hudson Ave., Suite 300Pasadena, CA 91101626.396.9599 www.TGArchitects.netAs indicated A-1.1 Checker Author 2015-09-3015-13 SITE PLANS501 N. Santa Anita Ave. Arcadia, CA 91006 SANTA ANITA CONDOMINIUMS 1/16" = 1'-0" 1 Second Floor Plan - Site 1/16" = 1'-0" 2 Roof Plan - Site N No.DescriptionDate DN DN 8.33% SLOPE (N) PLANTING 506.50 505.50 Line of Building Above 510.50 6" 7 A-1.3 - A-1.3 1 75/8" 3'-3" 75/8 " 3'-3" 7'-91/4" 5' - 0" 19' - 0" 5' - 0" 4' - 3" 12' - 0" 4'-0" (N)PLANTING 2 6 4 1 9'-0"7'-0"9'-0"6"3'-45/8" 19' - 0" 508.33 509.83 511.00 8.33% SLOPE (N) PLANTING 510.00 509.83 5' - 7" 22' - 0" 38' - 0" 5' - 0" 5' - 0" 3' - 7" 8' - 10" 3' - 7" 16' - 0"505.50- A-1.36 1 3-yd Bin for Green Waste (60"W x 48"Dx 48"H) 3-yd Bin forTrash (60"W x 48"Dx 48"H) 12" Min. Cleararound bins Roof Above 3-yd Bin forRecycling (60"W x 48"Dx 48"H) 5' - 5" 8'-6" Typical Parking StallAccessible Parking Stall 1' - 0" 9' - 0" 75 /8" 4 '-33/8 " 505.504 A-1.3 4'-11 " 5 2 5' - 0" 1' - 0" 510.92 1'-0"1'-10" 2'-10" 8.33% SLOPE8.33% SLOPE 1 6 2'-10 "1'-6"4'-6" 19 6'-0"3'-0" 9'-0" 6'-0" 9'-0" 1'-3" 3'-0" 2 8 5 5'-5" SITE DETAILS KEYNOTESCMU Wall w/ Stucco Finish 1 4'-6" Metal Fence 4 1:12 Cast-in-Place Concrete Ramp 56 Cast-in-Place Concrete StairsCMU Retaining Wall w/ Stucco Finish;See Struct. for Details 2 Cast-in-Pace Concrete Wall; See Struct. for Details 3 42" Metal Guardrail 7 36" Metal Handrail 8 Standing Seam Metal Roof w/ 5" Metal Posts 9 [Not Used] 10 First Floor South510' - 0" 4'-6"1'-0" 6'-0" 62 6" Varies First Floor South510' - 0" 6" Varies 63 1'-0"4'-6" 6'-0" 19 Metal Gates 3-yd Bin forTrash (60"W x 48"Dx 48"H) 3-yd Bin forRecycling (60"W x 48"Dx 48"H) 12" Min. Cleararound BinsRoof Above 8' - 6" 1'-11 "8'-2"1'-11 " 12 '-0 " A-1.31 509.50 A-1.3 5 19 Metal Gates A-1.312 509.00 6' - 8" 20' - 0" 5' - 5" 32' - 1" 1'-6"4'-6"(N) 4'-6" METAL FENCE(N) 1'-6" WALL W/STUCCO FINISH (N) 20'-0" VEHICULAR GATE Javier GonzalezNo. Cxxxxx Exp. x-xx-17 Robert G. TylerNo. C18812 Exp. 8-31-17 Date Reviewed Drawn ByDescription Do not scale drawings. Contractor shall verifyand be responsible for all dimensions andconditions on the site and Tyler Gonzalez Architects, Inc. shall be notified immediately ofany variations from the dimensions and conditions indicated on these drawings. Drawings, specifications, and other documents,including those in electronic form, prepared by the Architect and the Architect's consultants areInstruments of Service for use solely with respect to this Project. The Architect and theArchitect's consultants shall be deemed theauthors and owners of their respective Instruments of Service and shall retain all common law, statutory and other reserved rights, including copyrights. Visual contact withthese documents constitute prima faciaacceptance of these conditions.Architect of RecordIssue Dates Use of Architect's Drawings2015 Tyler Gonzalez Architects, Inc. c Sheet No.Project No.Scale 139 South Hudson Ave., Suite 300Pasadena, CA 91101626.396.9599 www.TGArchitects.net 1/4" = 1'-0" A-1.3 Checker Author 2015-09-3015-13 SITE DETAILS501 N. Santa Anita Ave. Arcadia, CA 91006 SANTA ANITA CONDOMINIUMS 1/4" = 1'-0" 10 Plan - 3 Bin Trash Enclosure, Accessible and Typical parkingspaces, and Accessible Ramp & Parking Space 1/4" = 1'-0" 3 Plan - Convenience Stair 1/4" = 1'-0" 7 Section - Accessible Ramp 1/4" = 1'-0" 1 Side Elevation - Trash Enclosure 1/4" = 1'-0" 4 Section - Convenience Stair 1/4" = 1'-0" 8 Section - Retaining Wall 1/4" = 1'-0" 9 Section - Tiered Retaining Wall No.DescriptionDate 1/4" = 1'-0" 6 South Elevation - Trash Enclosure 1/4" = 1'-0" 2 Plan - 2-Bin Trash Enclosure 1/4" = 1'-0" 5 West Elevation - Trash Enclosure 1/4" = 1'-0" 11 Plan - Vehicular Gate 1/4" = 1'-0" 12 Elevation - Vehicular Gate DN (E) LIGHT RAIL BRIDGELINE OF GRADE BEYONDTYP . 4'-6"TYP . 1'-6" 12'-5" 12'-4" 11'-10" 11'-2" PODACARPUSPLANTED TO SCREEN RETAININGWALL; TRIMMED TOTOP OF WALL (N) RETAINING WALL W/ STUCCOFINISH (HEIGHT VARIES)(N) 4'-6" METAL FENCE(N) 3" STONE CAP 12'-5" 12'-4" 11'-10" 11'-2" 10'-2 " 7'-11" 6'-11" MA TCHLINE PROPERTY LINE PR OP ERT YL INE COLORADO BOULEVARD 5'-0" (N) 4'-6" METAL FENCE(N) RETAINING WALL W/ STUCCOFINISH (HEIGHT VARIES) (N) 5'-0" PLANTING (E) PROTECTEDTREE TO REMAIN 509.50497.09 509.50497.19 509.50497.68 509.50498.33BOUNDARY OF (E) RETAININGSLOPE TO BE REMOVED (N) 5'-0" SIDEWALK 499.36 500.45 501.57 502.60 M A TCHLINE 509.50 509.50 509.50 509.50 (N) 5'-0" PLANTING(N) 5'-0" SIDEWALK 5'-0" AB CDF E KEY PLAN Colorado Blvd. SantaAnitaBlvd. M ATCHLINE Typ . 6'-7"Typ . 1'-6" Typ . 4'-6" 6'-5" 5'-3" 3'-7" (N) RETAINING WALL W/ STUCCOFINISH (HEIGHT VARIES)(N) 4'-6" METAL FENCE(N) 3" STONE CAP Typ . 4'-6 "Typ . 1 '-6" 506.50 508.33 (N) 4'-6" METAL FENCE(N) RETAINING WALL W/ STUCCOFINISH (HEIGHT VARIES) COLORADO BOULEVARD PROPERTY LINE (N) 5'-0" SIDEWALK PROPERTY LINE M A TCHLINE 509.50 509.50 509.50 509.50 505.90 507.40 504.45 4.99% SLOPE 8.33% SLOPE BUILDING F 509.29 (N) 2'-0" METAL FENCE(N) 1'-0" WALL W/STUCCO FINISH SANTA ANITA AVENUE (E) 5'-0" SIDEWALK PROPERTY LINE (E) 5'-0" SIDEWALK 510.20 509.88509.87 509.59 509.29 BUILDING E509.60 5'-0" 6'- 3" 5'-0" STREET/HIGHWAY EASEMENT (N) PLANTING (E) PROTECTED TREETO REMAIN (N) 4'-6" METAL FENCE(N) 1'-6" WALL W/STUCCO FINISH(N) METALPEDESTRIAN GATE(E) PROTECTED TREESTO REMAIN (N) 2'-0" METAL FENCE(N) 1'-0" WALL W/STUCCO FINISH 1'-6"4 '-6 " Typ . 1'-0"Typ . 2'-0" (N) 4'-6" METAL FENCE(N) 1'-6" WALL W/STUCCO FINISH(N) METALPEDESTRIAN GATE (N) 3" STONE CAP (N) 3" STONE CAP Javier GonzalezNo. Cxxxxx Exp. x-xx-17 Robert G. TylerNo. C18812 Exp. 8-31-17 Date Reviewed Drawn ByDescription Do not scale drawings. Contractor shall verifyand be responsible for all dimensions andconditions on the site and Tyler Gonzalez Architects, Inc. shall be notified immediately ofany variations from the dimensions and conditions indicated on these drawings. Drawings, specifications, and other documents,including those in electronic form, prepared by the Architect and the Architect's consultants areInstruments of Service for use solely with respect to this Project. The Architect and theArchitect's consultants shall be deemed theauthors and owners of their respective Instruments of Service and shall retain all common law, statutory and other reserved rights, including copyrights. Visual contact withthese documents constitute prima faciaacceptance of these conditions.Architect of RecordIssue Dates Use of Architect's Drawings2015 Tyler Gonzalez Architects, Inc. c Sheet No.Project No.Scale 139 South Hudson Ave., Suite 300Pasadena, CA 91101626.396.9599 www.TGArchitects.netAs indicated A-1.4 Checker Author 2015-09-3015-13 SITE DETAILS501 N. Santa Anita Ave. Arcadia, CA 91006 SANTA ANITA CONDOMINIUMS No.DescriptionDate 1/8" = 1'-0" 2 Elevation - Colorado Boulevard Fence West 1/8" = 1'-0" 1 Plan - Colorado Boulevard Fence West 1/8" = 1'-0" 4 Elevation - Colorado Boulevard Fence East 1/8" = 1'-0" 3 Plan - Colorado Boulevard Fence East 1/8" = 1'-0" 5 Plan - Santa Anita Avenue Fence 1/8" = 1'-0" 6 Context East Elevation - Santa Anita Avenue Fence Javier GonzalezNo. Cxxxxx Exp. x-xx-17 Robert G. TylerNo. C18812 Exp. 8-31-17 Date Reviewed Drawn ByDescription Do not scale drawings. Contractor shall verifyand be responsible for all dimensions andconditions on the site and Tyler Gonzalez Architects, Inc. shall be notified immediately ofany variations from the dimensions and conditions indicated on these drawings. Drawings, specifications, and other documents,including those in electronic form, prepared by the Architect and the Architect's consultants areInstruments of Service for use solely with respect to this Project. The Architect and theArchitect's consultants shall be deemed theauthors and owners of their respective Instruments of Service and shall retain all common law, statutory and other reserved rights, including copyrights. Visual contact withthese documents constitute prima faciaacceptance of these conditions.Architect of RecordIssue Dates Use of Architect's Drawings2015 Tyler Gonzalez Architects, Inc. c Sheet No.Project No.Scale 139 South Hudson Ave., Suite 300Pasadena, CA 91101626.396.9599 www.TGArchitects.netA-1.5 Checker Author 2015-09-3015-13PERSPECTIVES501 N. Santa Anita Ave. Arcadia, CA 91006 SANTA ANITA CONDOMINIUMS No.DescriptionDate FO R IN- HOU SE USE ONL Y FO R IN- HOU SE USE ONL Y VIEW FROM SANTA ANITA AVE. & COLORADO BLVD. LOOKING NORTHWESTVIEW FROM CORNELL DRIVE LOOKING EAST Javier GonzalezNo. Cxxxxx Exp. x-xx-17 Robert G. TylerNo. C18812 Exp. 8-31-17 Date Reviewed Drawn ByDescription Do not scale drawings. Contractor shall verifyand be responsible for all dimensions andconditions on the site and Tyler Gonzalez Architects, Inc. shall be notified immediately ofany variations from the dimensions and conditions indicated on these drawings. Drawings, specifications, and other documents,including those in electronic form, prepared by the Architect and the Architect's consultants areInstruments of Service for use solely with respect to this Project. The Architect and theArchitect's consultants shall be deemed theauthors and owners of their respective Instruments of Service and shall retain all common law, statutory and other reserved rights, including copyrights. Visual contact withthese documents constitute prima faciaacceptance of these conditions.Architect of RecordIssue Dates Use of Architect's Drawings2015 Tyler Gonzalez Architects, Inc. c Sheet No.Project No.Scale 139 South Hudson Ave., Suite 300Pasadena, CA 91101626.396.9599 www.TGArchitects.netA-1.6 Checker Author 2015-09-3015-13PERSPECTIVES501 N. Santa Anita Ave. Arcadia, CA 91006 SANTA ANITA CONDOMINIUMS No.DescriptionDate FO R IN- HOU SE USE ONL Y FO R IN- HOU SE USE ONL YVIEW FROM COLORADO BLVD. LOOKING NORTHEASTVIEW FROM SANTA ANITA AVE. LOOKING WEST Javier GonzalezNo. Cxxxxx Exp. x-xx-17 Robert G. TylerNo. C18812 Exp. 8-31-17 Date Reviewed Drawn ByDescription Do not scale drawings. Contractor shall verifyand be responsible for all dimensions andconditions on the site and Tyler Gonzalez Architects, Inc. shall be notified immediately ofany variations from the dimensions and conditions indicated on these drawings. Drawings, specifications, and other documents,including those in electronic form, prepared by the Architect and the Architect's consultants areInstruments of Service for use solely with respect to this Project. The Architect and theArchitect's consultants shall be deemed theauthors and owners of their respective Instruments of Service and shall retain all common law, statutory and other reserved rights, including copyrights. Visual contact withthese documents constitute prima faciaacceptance of these conditions.Architect of RecordIssue Dates Use of Architect's Drawings2015 Tyler Gonzalez Architects, Inc. c Sheet No.Project No.Scale 139 South Hudson Ave., Suite 300Pasadena, CA 91101626.396.9599 www.TGArchitects.netA-1.7 Checker Author 2015-09-3015-13PERSPECTIVES501 N. Santa Anita Ave. Arcadia, CA 91006 SANTA ANITA CONDOMINIUMS No.DescriptionDate FO R IN- HOU SE USE ONL Y VIEW FROM WINDSOR ROAD LOOKING EAST KL 3 1 2 510.00 509.40 510.00509.40 A-3.2.A2 A-3.2.B 2 LIVING GARAGE DINING GARAGE PWDR.CL LIVING ENTRY KITCHEN DINING WD 1 A-4.0 40' - 7" 32' - 7" 4" 19' - 10 3/4" 6' - 3" 12' - 11" 1' - 2 1/4" 13' - 4 1/2" 5' - 3" 3' - 2" 7' - 0 1/4" 3' - 9 1/4" EQ EQ 6' - 8 1/4" 6' - 2 3/4" 6' - 1 1/8" 7' - 3 3/8" EQ EQ EQ EQ 73' - 2" 15' - 10 1/4" 7' - 6 3/4" 15' - 11 3/4" 1' - 2 1/4" 12' - 8" 19' - 11" 6' - 7" 4' - 1 1/2" 3' - 0" 6' - 2 1/2" 6' - 1 1/8" 6' - 6 7/8" 9' - 9" 6' - 2 3/4" 2' - 9" 4' - 7 1/4" 3' - 6" 5' - 0" 1'-11/2"1'-9"2'-53/4"3'-113/4"2'-9"14'-111/2"6'-21/4"2'-11/2" 7'-63/4"7'-43/4" 2'-3" 20'-2"7'-63/4"5'-6"2'-11/2" EQEQ 1'-6" UNIT 1 UNIT 2 35'-41/4" KITCHEN 3 3 4 4 37 37 8 3 2 2 17 3 2 82 17 2 2 6 2 2 126 12 5 6 20 20 AB CDF E KEY PLAN Colorado Blvd. SantaAnitaBlvd. FLOOR PLAN KEYNOTESKitchen Sink. See Plumbing Drawings. Accessible Kitchen Sink with removable basecabinet below, meeting all requirements of Section1133A.3. Flooring shall continue underneath.Faucet controls meeting all requirements of Section1133A.3. See Plumbing Drawings. Range & Vent Hood O.F.C.I.See Mechanical Drawings . Refrigerator O.F.C.I. 36"W, Standard DepthDishwasher O.F.C.I. 1 1A234 Base Cabinet and Solid-surface Cabinet Top with TileSplash. Owner to select. See Casework Notes . 5 Upper Cabinets. See Casework Notes . 6 Lavatory. See Plumbing Drawings. 7 Accessible Lavatory with removable base cabinetbelow, meeting all requirements of Section 1134A.8.Flooring shall continue underneath. Faucet controlsmeeting all requirements of Section 1133A.3. SeePlumbing Drawings. 7A 30"x48" Clear Floor Space for accessibleappliances & fixtures. See Sheet G-1.2 . Floor-mounted Water Closet.See Plumbing Drawings. 8 Accessible Floor-mounted Water Closet meeting allrequirements of Section 1134A.7. 15" min. seatheight. 44" max. Water Closet controls above floor.5 lb. max. force to operate See Sheet G-1.2 . See Plumbing Drawings. 8A Shower with tile walls to ceiling and tile floor. Slopeshower floor to drain. See Plumbing Drawings. 9 Accessible Shower meeting all requirements ofSection 1134A.5&6. Tile walls to ceiling and tilefloor. Slope shower floor to drain. See Sheet G-1.2 . See Plumbing Drawings. 9A Bathtub. See Plumbing Drawings. 11 Jacuzzi Bathtub. See Plumbing Drawings. 12 Wall-mounted Mirror. 13 Frameless tempered glass Shower Enclosure/doors. 10 Recessed Medicine Cabinet. Cabinet Door withmirror, prefinished painted metal interior withadjustable shelves. 14 Side-by-Side Washer & Dryer, O.F.C.I. 15 Stacked Washer & Dryer, O.F.C.I. 16 GS Smitty Pan with drain under Washer & Dryer. 17 Automatic Washing Machine Water Shutoff Valvewith leak sensor: Intelliflow, Series A2C-M1. 18 Dryer Exhaust Vent Duct, min. 4" diameter, to theoutside, equipped with back-draft damper 19 Interior Stair. See Sheet A-9.6 for stair and handrail details. 21 Provide min. one layer of 5/8" gypsum board atusable underside of stairs. CBC 1009.5.3. 22 Closet rod and 16" shelf above. 23 Full-height linen cabinet. 24 Water heater on 18" high platform above floor. SeeMEP Drawings. Provide 2" galvanized steelrestarining straps to wall. 20 Balcony with approved weatherproof walkingsurface/deck coating system: Dex-O-Tex, or approvedequal, over plywood framing (see Structural Drawings ). Slope min. 1/4" per ft. along flow line. See Sheet A-9.4 for details. 25 Min. 42" high Guardrail. For Details, see: 26 Deck drain. Slope to drain. 27 Outline of Building above. 28 Outline of Roof or Balcony above. 29 Edge of soffit above. See Reflected Ceiling Plans. 30 Clerestory above. For Plans, see: 31 Internal Roof Drain/Overflow Drain. See Plumbing Drawings . Provide installation submittal under Section 075423 (Roofing) for Architect's review.Overflow Drains shall discharge above grade. 34 Type AA-9.41 Type B Type C A-9.44 A-9.47 Type A Type B Type C A-2.61 A-2.63 A-2.65 Clerestory Window above. See Sheet A-2.6 for Plans. 32 2"x4" Prefinished Metal Downspout to dischargeabove grade, typ. 35 Decorative Metal Screen. 36 Air Handling Unit. See Mechanical Drawings . 37 Skylight above. 33 Door Bell. 48" max. AFF andconnected to permanent wiring. 39 Floor Transition & Railing. See Detail 38 A-9.22 Space for Vertical Ductwork. 40 [Note intentionally left blank] 41 [Note intentionally left blank] 42 [Note intentionally left blank] 43 [Note intentionally left blank] 44 [Note intentionally left blank] 45 [Note intentionally left blank] 46 [Note intentionally left blank] 47 LEGENDSoffited Ceiling. See Reflected Ceiling Plansfor heights and details. Javier GonzalezNo. Cxxxxx Exp. x-xx-17 Robert G. TylerNo. C18812 Exp. 8-31-17 Date Reviewed Drawn ByDescription Do not scale drawings. Contractor shall verifyand be responsible for all dimensions andconditions on the site and Tyler Gonzalez Architects, Inc. shall be notified immediately ofany variations from the dimensions and conditions indicated on these drawings. Drawings, specifications, and other documents,including those in electronic form, prepared by the Architect and the Architect's consultants areInstruments of Service for use solely with respect to this Project. The Architect and theArchitect's consultants shall be deemed theauthors and owners of their respective Instruments of Service and shall retain all common law, statutory and other reserved rights, including copyrights. Visual contact withthese documents constitute prima faciaacceptance of these conditions.Architect of RecordIssue Dates Use of Architect's Drawings2015 Tyler Gonzalez Architects, Inc. c Sheet No.Project No.Scale 139 South Hudson Ave., Suite 300Pasadena, CA 91101626.396.9599 www.TGArchitects.netAs indicated A-2.0.A Checker Author 2015-09-3015-13 FLOOR PLANS - BUILDING A501 N. Santa Anita Ave. Arcadia, CA 91006 SANTA ANITA CONDOMINIUMS 1/4" = 1'-0" 1 First Floor Plan - Building A N No.DescriptionDate KL 3 1 2 1/2"/1'-0" 1/2" / 1'-0" 1/2"/1'-0" 2" / 1'-0" 2" / 1'-0" 2"/1 '-0"2"/1'-0" 1/2"/1'-0" 1/2" / 1'-0" 1 A-4.0 3/8"/1'-0" 3/8" / 1'-0" 3/8" / 1'-0" 3/8"/1'-0" 3/8" / 1'-0" 3/8" / 1'-0" 533.00 3/8" / 1'-0" 3/8" / 1'-0" 3/8"/1'-0 " 533.00 531.82 531.82 Typ. 2' - 0" Typ. 2' - 0" Typ . 2'-0" 40' - 7" 32' - 7" 4" 19' - 10 3/4" 7' - 10 3/4" 11' - 3 1/4" 1' - 2 1/4" 13' - 5 1/2" 15' - 4 1/4" 3' - 9 1/4" 2' - 6" 75' - 8" 4" 2' - 9" 12' - 9 1/4" 7' - 6 3/4" 15' - 10 3/4" 1' - 3 1/4" 13' - 4 1/2" 15' - 5 1/4" 3' - 9 1/4" 2' - 6" 35'-41/4 " 1'-11/2"1'-9"2'-53/4"4'-33/4"2'-9"20'-03/4"9"2'-11/2" 1'-11/2"2'-0"6'-31/4"13'-31/4 "5'-03/4"7'-71/2" 1/2"/1'-0" 1/2" / 1'-0" 4'-9"2'-101/2" 58 51 55 50 53 56 50 53 51 533.00 56 55 52 58 585255 56 53 51 58 5155 58 51 55 54 54 5757 532.00 KL 3 1 2 521.00 521.00 A-3.2.A2 A-3.2.A1 A-3.2.B 1 A-3.2.B 2 M. BEDRM. BATH BEDRM. 2 CL BEDRM. 3 LINEN DECK BALCONY DECK DECK BEDRM. 3 CL M. BEDRM. W.I.C.M. BATH BATH BEDRM. 2 1 A-4.0 UNIT 1 UNIT 2 40' - 7" 32' - 7" 4" 11' - 3 1/4" 1' - 2 1/4" 13' - 4 1/2" 15' - 5 1/4" 3' - 9 1/4" 2' - 6" 75' - 8" 4" 2' - 9" 12' - 9 1/4" 7' - 6 3/4" 15' - 11 3/4" 1' - 2 1/4" 13' - 4 1/2" 19' - 2 1/2" 2' - 6" 1'-11/2"1'-9"2'-53/4"4'-33/4"2'-9"20'-93/4"2'-11/2" 1'-11/2"2'-0"19'-61/2 "5'-03/4"7'-71/2" 4' - 3 1/4" 3' - 6" 5' - 0" 3' - 4 3/8" 4' - 2 3/8" 9' - 9" 6' - 2 3/4" 6' - 1 1/8" 7' - 3 3/8" 5' - 10 1/2" 10' - 4" 3' - 0" 7'-81/4"4'-101/2"4'-101/2"2'-11/4"3'-05/8"2'-01/8" EQ EQ 3' - 1 1/2" 4' - 9 1/4" 5' - 0 1/2" 6' - 2 3/4" 6' - 1 1/8" 7' - 3 3/8" 2' - 3 1/2" 9' - 9 3/8" 3' - 4 3/8" 35'-41 /4" HALL HALL 2 2 2 2 22 2 2 2 2 2 1 5 5 5 11A 7 15 15 3 3 3 33 7A 3 9A 1211 18 19 18 19 52 W&D CL 3 M. BATH W.I.C. 9" 7'-71/2" 11'-10"3'-6"5'-53/4"2'-01/8"2'-35/8" AB CDF E KEY PLAN Colorado Blvd. SantaAnitaBlvd. ROOF PLAN KEYNOTESCCRC-Applied Cool Roof, Firestone, TPO.Specified Class-A Built-Up RoofingTyp. Parapet. See detailRoof Drain / Overflow Drain. See Plumbing Drawings. Provide installation submittal under Section 075423(Plumbing) for Architect's review. Overflow drainsshall discharge above grade.Roof Eave. For Details, see:Line of Building Below 505153565558 A-9.54 Parapet & Roof Connection. See detail 54 A-9.57 Type A Type B Type C A-9.51 A-9.55 A-9.58 4"x6" Aluminum Gutter with Location of Downspoutbelow. 57 Standing Seam Metal Roof 52 Rooftop Air Conditioning Unit (screened or concealed) 59 FLOOR PLAN KEYNOTESKitchen Sink. See Plumbing Drawings. Accessible Kitchen Sink with removable basecabinet below, meeting all requirements of Section1133A.3. Flooring shall continue underneath.Faucet controls meeting all requirements of Section1133A.3. See Plumbing Drawings. Range & Vent Hood O.F.C.I.See Mechanical Drawings . Refrigerator O.F.C.I. 36"W, Standard DepthDishwasher O.F.C.I. 1 1A234 Base Cabinet and Solid-surface Cabinet Top with TileSplash. Owner to select. See Casework Notes . 5 Upper Cabinets. See Casework Notes . 6 Lavatory. See Plumbing Drawings. 7 Accessible Lavatory with removable base cabinetbelow, meeting all requirements of Section 1134A.8.Flooring shall continue underneath. Faucet controlsmeeting all requirements of Section 1133A.3. SeePlumbing Drawings. 7A 30"x48" Clear Floor Space for accessibleappliances & fixtures. See Sheet G-1.2 . Floor-mounted Water Closet.See Plumbing Drawings. 8 Accessible Floor-mounted Water Closet meeting allrequirements of Section 1134A.7. 15" min. seatheight. 44" max. Water Closet controls above floor.5 lb. max. force to operate See Sheet G-1.2 . See Plumbing Drawings. 8A Shower with tile walls to ceiling and tile floor. Slopeshower floor to drain. See Plumbing Drawings. 9 Accessible Shower meeting all requirements ofSection 1134A.5&6. Tile walls to ceiling and tilefloor. Slope shower floor to drain. See Sheet G-1.2 . See Plumbing Drawings. 9A Bathtub. See Plumbing Drawings. 11 Jacuzzi Bathtub. See Plumbing Drawings. 12 Wall-mounted Mirror. 13 Frameless tempered glass Shower Enclosure/doors. 10 Recessed Medicine Cabinet. Cabinet Door withmirror, prefinished painted metal interior withadjustable shelves. 14 Side-by-Side Washer & Dryer, O.F.C.I. 15 Stacked Washer & Dryer, O.F.C.I. 16 GS Smitty Pan with drain under Washer & Dryer. 17 Automatic Washing Machine Water Shutoff Valvewith leak sensor: Intelliflow, Series A2C-M1. 18 Dryer Exhaust Vent Duct, min. 4" diameter, to theoutside, equipped with back-draft damper 19 Interior Stair. See Sheet A-9.6 for stair and handrail details. 21 Provide min. one layer of 5/8" gypsum board atusable underside of stairs. CBC 1009.5.3. 22 Closet rod and 16" shelf above. 23 Full-height linen cabinet. 24 Water heater on 18" high platform above floor. SeeMEP Drawings. Provide 2" galvanized steelrestarining straps to wall. 20 Balcony with approved weatherproof walkingsurface/deck coating system: Dex-O-Tex, or approvedequal, over plywood framing (see Structural Drawings ). Slope min. 1/4" per ft. along flow line. See Sheet A-9.4 for details. 25 Min. 42" high Guardrail. For Details, see: 26 Deck drain. Slope to drain. 27 Outline of Building above. 28 Outline of Roof or Balcony above. 29 Edge of soffit above. See Reflected Ceiling Plans. 30 Clerestory above. For Plans, see: 31 Internal Roof Drain/Overflow Drain. See Plumbing Drawings . Provide installation submittal under Section 075423 (Roofing) for Architect's review.Overflow Drains shall discharge above grade. 34 Type AA-9.41 Type B Type C A-9.44 A-9.47 Type A Type B Type C A-2.61 A-2.63 A-2.65 Clerestory Window above. See Sheet A-2.6 for Plans. 32 2"x4" Prefinished Metal Downspout to dischargeabove grade, typ. 35 Decorative Metal Screen. 36 Air Handling Unit. See Mechanical Drawings . 37 Skylight above. 33 Door Bell. 48" max. AFF andconnected to permanent wiring. 39 Floor Transition & Railing. See Detail 38 A-9.22 Space for Vertical Ductwork. 40 [Note intentionally left blank] 41 [Note intentionally left blank] 42 [Note intentionally left blank] 43 [Note intentionally left blank] 44 [Note intentionally left blank] 45 [Note intentionally left blank] 46 [Note intentionally left blank] 47 LEGENDSoffited Ceiling. See Reflected Ceiling Plansfor heights and details. Javier GonzalezNo. Cxxxxx Exp. x-xx-17 Robert G. TylerNo. C18812 Exp. 8-31-17 Date Reviewed Drawn ByDescription Do not scale drawings. Contractor shall verifyand be responsible for all dimensions andconditions on the site and Tyler Gonzalez Architects, Inc. shall be notified immediately ofany variations from the dimensions and conditions indicated on these drawings. Drawings, specifications, and other documents,including those in electronic form, prepared by the Architect and the Architect's consultants areInstruments of Service for use solely with respect to this Project. The Architect and theArchitect's consultants shall be deemed theauthors and owners of their respective Instruments of Service and shall retain all common law, statutory and other reserved rights, including copyrights. Visual contact withthese documents constitute prima faciaacceptance of these conditions.Architect of RecordIssue Dates Use of Architect's Drawings2015 Tyler Gonzalez Architects, Inc. c Sheet No.Project No.Scale 139 South Hudson Ave., Suite 300Pasadena, CA 91101626.396.9599 www.TGArchitects.netAs indicated A-2.0.B Checker Author 2015-09-3015-13 FLOOR PLANS - BUILDING A501 N. Santa Anita Ave. Arcadia, CA 91006 SANTA ANITA CONDOMINIUMS 1/4" = 1'-0" 2 Roof Plan - Building A 1/4" = 1'-0" 1 Second Floor Plan - Building A N No.DescriptionDate 1/4" = 1'-0"Floor Plan Key Notes 4 5 J A-3.3 4 A-3.33 A-3.3 2 A-3.31 2 A-4.0 509.40 510.00 STOR. BATH 2BEDRM. 2 ENTRY KITCHENDININGLIVING GARAGE UNIT 335' - 10 1/4" 2' - 6" 19' - 11" 12' - 2 3/4" 10 1/2" 4" 6' - 2 1/2" 3' - 0" 4' - 1 1/2" 6' - 7" 7' - 1 1/2" 2' - 4" 2' - 9 1/4" 81 /2"18'-11/4"45/8" 14'-31/4"3'-10" 11'-8 "5'-63/4"9" 7'-01/2"4'-71/2"3'-1"2'-53/4" 1'-6" 2' - 5" 10' - 7" 5' - 3" 1' - 1 1/4" 7' - 2 1/2" 8' - 10 7/8" 4 5/8" 4' - 11 1/2" 5' - 7 1/2" EQ EQ 4' - 2 7/8" 4' - 8" M 10'-1 "9'-41/2" 19'-51/2" 37'-51/4" 2'-11/2" 3 4 37 8 2 22 3 2 17 2 2 3 3 7 3 3 12 10 6 9 3'-6"12'-73/8 " 1'-111/2" 1'-61/2" 20 4 5 J 2 A-4.0 1/2"/1'-0" 1/2" / 1'-0" 1/2"/1'-0" 1/2" / 1'-0" 2" / 1'-0" 2" / 1'-0" 3/8" / 1'-0" 3/8"/1'-0" 3/8" / 1'-0" 533.00 533.00 531.82 531.82 Typ. 2' - 0" Typ. 2' - 0" 36' - 10 1/4" 1' - 0" 22' - 5" 3' - 6" 9' - 3 1/4" 8" 111/2"18'-51/4"15'-10"4" 17'-7"1'-111/2"9'-81/2"5'-113/4"4" 1' - 0" 19' - 8 1/4" 15' - 10" 4" M 1'-101 /2" 37'-51/4" 2"/1'-0"2"/1'-0" UNIT 3 58 51 57 58 52 55 56 53 50 50 56 53 55 54 54 4 5 J A-3.3 4 A-3.33 A-3.3 2 A-3.31 2 A-4.0 521.00 M. BEDRM.M. BATH BATH 3 BEDRM. 3 STUDY HALL BALC. DECK BEDRM. 4 UNIT 336' - 10 1/4" 1' - 0" 25' - 11" 9' - 3 1/4" 8" 6' - 1 1/2" 6' - 4" 6' - 4" 7' - 1 1/2" 3' - 7 1/2" 2' - 4" 3' - 3 3/4" 111/2"18'-11/4"12'-71/2 "3'-101/2" 2'-41/8" 1'-63/8" 1'-105/8"10'-87/8 "6'-2"3'-0"3'-0"5'-111 /4" 19'-61/2"9'-81/2"6'-33/4" 2'-6"7'-6"9'-61/2"5'-1"4'-71/2" 1' - 0" 19' - 4 1/4" 7' - 2 1/2" 9' - 3 1/2" 4' - 7 1/2" 5' - 6" 5' - 6" 3' - 8 3/4" 5' - 3 7/8" 1' - 10 5/8" 4' - 2 7/8" 5' - 0 5/8"A-2.68 M 1'-101 /2" 37'-51 /4" 3 2 2 2 2 7A 2 26 26 5 5 2 1 13 8 8 3 3A 3A 33 7A 7A 7A 26 23 1523233A3A3A W&D AB CDF E KEY PLAN Colorado Blvd. SantaAnitaBlvd. ROOF PLAN KEYNOTESCCRC-Applied Cool Roof, Firestone, TPO.Specified Class-A Built-Up RoofingTyp. Parapet. See detailRoof Drain / Overflow Drain. See Plumbing Drawings. Provide installation submittal under Section 075423(Plumbing) for Architect's review. Overflow drainsshall discharge above grade.Roof Eave. For Details, see:Line of Building Below 505153565558 A-9.54 Parapet & Roof Connection. See detail 54 A-9.57 Type A Type B Type C A-9.51 A-9.55 A-9.58 4"x6" Aluminum Gutter with Location of Downspoutbelow. 57 Standing Seam Metal Roof 52 Rooftop Air Conditioning Unit (screened or concealed) 59 FLOOR PLAN KEYNOTESKitchen Sink. See Plumbing Drawings. Accessible Kitchen Sink with removable basecabinet below, meeting all requirements of Section1133A.3. Flooring shall continue underneath.Faucet controls meeting all requirements of Section1133A.3. See Plumbing Drawings. Range & Vent Hood O.F.C.I.See Mechanical Drawings . Refrigerator O.F.C.I. 36"W, Standard DepthDishwasher O.F.C.I. 1 1A234 Base Cabinet and Solid-surface Cabinet Top with TileSplash. Owner to select. See Casework Notes . 5 Upper Cabinets. See Casework Notes . 6 Lavatory. See Plumbing Drawings. 7 Accessible Lavatory with removable base cabinetbelow, meeting all requirements of Section 1134A.8.Flooring shall continue underneath. Faucet controlsmeeting all requirements of Section 1133A.3. SeePlumbing Drawings. 7A 30"x48" Clear Floor Space for accessibleappliances & fixtures. See Sheet G-1.2 . Floor-mounted Water Closet.See Plumbing Drawings. 8 Accessible Floor-mounted Water Closet meeting allrequirements of Section 1134A.7. 15" min. seatheight. 44" max. Water Closet controls above floor.5 lb. max. force to operate See Sheet G-1.2 . See Plumbing Drawings. 8A Shower with tile walls to ceiling and tile floor. Slopeshower floor to drain. See Plumbing Drawings. 9 Accessible Shower meeting all requirements ofSection 1134A.5&6. Tile walls to ceiling and tilefloor. Slope shower floor to drain. See Sheet G-1.2 . See Plumbing Drawings. 9A Bathtub. See Plumbing Drawings. 11 Jacuzzi Bathtub. See Plumbing Drawings. 12 Wall-mounted Mirror. 13 Frameless tempered glass Shower Enclosure/doors. 10 Recessed Medicine Cabinet. Cabinet Door withmirror, prefinished painted metal interior withadjustable shelves. 14 Side-by-Side Washer & Dryer, O.F.C.I. 15 Stacked Washer & Dryer, O.F.C.I. 16 GS Smitty Pan with drain under Washer & Dryer. 17 Automatic Washing Machine Water Shutoff Valvewith leak sensor: Intelliflow, Series A2C-M1. 18 Dryer Exhaust Vent Duct, min. 4" diameter, to theoutside, equipped with back-draft damper 19 Interior Stair. See Sheet A-9.6 for stair and handrail details. 21 Provide min. one layer of 5/8" gypsum board atusable underside of stairs. CBC 1009.5.3. 22 Closet rod and 16" shelf above. 23 Full-height linen cabinet. 24 Water heater on 18" high platform above floor. SeeMEP Drawings. Provide 2" galvanized steelrestarining straps to wall. 20 Balcony with approved weatherproof walkingsurface/deck coating system: Dex-O-Tex, or approvedequal, over plywood framing (see Structural Drawings ). Slope min. 1/4" per ft. along flow line. See Sheet A-9.4 for details. 25 Min. 42" high Guardrail. For Details, see: 26 Deck drain. Slope to drain. 27 Outline of Building above. 28 Outline of Roof or Balcony above. 29 Edge of soffit above. See Reflected Ceiling Plans. 30 Clerestory above. For Plans, see: 31 Internal Roof Drain/Overflow Drain. See Plumbing Drawings . Provide installation submittal under Section 075423 (Roofing) for Architect's review.Overflow Drains shall discharge above grade. 34 Type AA-9.41 Type B Type C A-9.44 A-9.47 Type A Type B Type C A-2.61 A-2.63 A-2.65 Clerestory Window above. See Sheet A-2.6 for Plans. 32 2"x4" Prefinished Metal Downspout to dischargeabove grade, typ. 35 Decorative Metal Screen. 36 Air Handling Unit. See Mechanical Drawings . 37 Skylight above. 33 Door Bell. 48" max. AFF andconnected to permanent wiring. 39 Floor Transition & Railing. See Detail 38 A-9.22 Space for Vertical Ductwork. 40 [Note intentionally left blank] 41 [Note intentionally left blank] 42 [Note intentionally left blank] 43 [Note intentionally left blank] 44 [Note intentionally left blank] 45 [Note intentionally left blank] 46 [Note intentionally left blank] 47 LEGENDSoffited Ceiling. See Reflected Ceiling Plansfor heights and details. Javier GonzalezNo. Cxxxxx Exp. x-xx-17 Robert G. TylerNo. C18812 Exp. 8-31-17 Date Reviewed Drawn ByDescription Do not scale drawings. Contractor shall verifyand be responsible for all dimensions andconditions on the site and Tyler Gonzalez Architects, Inc. shall be notified immediately ofany variations from the dimensions and conditions indicated on these drawings. Drawings, specifications, and other documents,including those in electronic form, prepared by the Architect and the Architect's consultants areInstruments of Service for use solely with respect to this Project. The Architect and theArchitect's consultants shall be deemed theauthors and owners of their respective Instruments of Service and shall retain all common law, statutory and other reserved rights, including copyrights. Visual contact withthese documents constitute prima faciaacceptance of these conditions.Architect of RecordIssue Dates Use of Architect's Drawings2015 Tyler Gonzalez Architects, Inc. c Sheet No.Project No.Scale 139 South Hudson Ave., Suite 300Pasadena, CA 91101626.396.9599 www.TGArchitects.netAs indicated A-2.1 Checker Author 2015-09-3015-13 FLOOR PLANS - BUILDING B501 N. Santa Anita Ave. Arcadia, CA 91006 SANTA ANITA CONDOMINIUMS 1/4" = 1'-0" 1 First Floor Plan - Building B 1/4" = 1'-0" 3 Roof Plan - Building B 1/4" = 1'-0" 2 Second Floor Plan - Building B N No.DescriptionDate 1/4" = 1'-0"Floor Plan Key Notes DN DN DN 17 14 F 15 16 GARAGE C1 B1 W1 F1 LIVINGC1 B1 W1 F1 DININGC1 B1 W1 F1KITCHENCL C2 B2 W2 F3 PWDR. C2 B2 W2 F3 PWDR. C1 B1 W1 F1 ENTRY C1 B1 W1 F1 ENTRY C1 B1 W1 F1 LIVING C1 B1 W1 F1 DINING 510.00 509.40 C1 B1 W1 F1KITCHEN 511.17 511.17 515.17 STOR. A-3.4.A1 A-3.4.A2 A-3.4.B 1 A-3.4.B 2 4 A-4.0 UNIT 4 UNIT 5 UNIT 6 38' - 1 1/4" 26' - 2 3/4" 26' - 6" 4' - 1" 3' - 0 1/2" 16' - 6 1/2" 14' - 2" 3 1/4" 16' - 0 3/4" 10' - 2" 10' - 2" 16' - 4" EQ EQ 2' - 0" 5' - 7 1/2" 2' - 6 1/2" 2' - 6 1/2" 5' - 7 1/2" 2' - 0" 7' - 10 3/4" 8' - 2" 14' - 3 1/2" 2' - 3" 7' - 4" 6' - 10" 4' - 1" 15' - 1 1/2" 18' - 7 1/2" 19' - 0" 7' - 2 3/4" 3 1/4" 3 1/4" 7' - 2 3/4" 19' - 0" 90' - 10" 6' - 2" 8' - 11 1/2" 11' - 9 1/2" 6' - 10" 5' - 9 1/2" 3' - 8" 9' - 6 1/2" EQ EQ EQ EQ 9' - 6 1/2" 3' - 8" 5' - 9 1/2" 2'-0"10'-0 "9'-81/4"16'-43/4" 9'-23/4"7'-2"EQEQ 2'-0" 1'-61/4"1'-13/4" 4"19'-81/2"2'-93/4"7'-113/4"1'-4"1'-3" EQEQ A 36'-1" 1 A-4.2 5 A-4.0 3 3 3 4 1 2 5 6 875 38 30 26 Type A C1 B1 W1 F1 ENTRY C1 B1 W1 F1 LIVING C1 B1 W1 F1 DINING C1 B1 W1 F1KITCHEN 30 8 4 1 2 5 6 BALC. C2 B2 W2 F3 PWDR. 3 3 20 25 4 4 4 4 3 20 15 38 30 10 10 8 8 14 8 2 2 23 17 2 2 37 17 18 6 22 515.17 13 BALC. BALC. 34 35 34 34 35 35 35 2 4 1 5 6 13 7 5 22 21 22 21 26 Type A 28 28 39 39 39 35 25 25 25 21 32 23 29 34 34 34 29 35 6 13 20 17 14 F 15 16 C1 B3 W1 F4GARAGE C2 B2 W2 F3LAUNDRY C2 B2 W2 F3LAUNDRY C1 B3 W1 F4GARAGE 505.92 505.92 A-3.4.B 1 A-3.4.B 2 4 A-4.0 26' - 2 3/4" 26' - 6" 2 3/4" 20' - 0 1/4" 6' - 2 1/2" 6' - 2 1/2" 20' - 3 1/2" 52' - 11 1/2" 20'-21 /4"15'-103/4" 9' - 10 1/2" 10' - 1 3/4" EQ EQ A 1 A-4.2 5 A-4.0 505.92 505.92 1/4"/1'-0" 1/4"/1'-0 " C1 B3 W1 F4 STOR C1 B3 W1 F4 STOR 3 3 17 3 3 17 37 37 38 15 17 18 15 17 18 22 21 21 22 28 28 28 28 38 36 35 35 505.50 505.50 PLANTER 29 34 34 34 35 20 20 20 AB CDF E KEY PLAN Colorado Blvd. SantaAnitaBlvd. FINISH LEGENDEngineered Wood Flooring O.F.C.I. FloorsF1 Carpet over pad O.F.C.I. F2 Porcelain Tile over fiber-cement backer units,complying with TCNA assembly F144-11, withwaterproof membrane O.F.C.I. F3 Polished Concrete F4 Eggshell Latex WallsW1 Low-Sheet Latex (Bath & Laundry) W2 (All painted 5/8" Type X gypsum wallboard)Typical base: 6" high, square, painted BaseB1 Porcelain Tile base installed over cementitious backerunits. Provide allowance of $8/sf (tile material only) B2 [No base] B3 Eggshell Latex CeilingsC1 Low-Sheet Latex (Bath & Laundry) C2 (All painted 5/8" Type X gypsum wallboard)PLAN GENERAL NOTESRefer to accessibility sheets (G-1 Series) for additionalinformation & requirements. 1. Install all bathroom accessor ies (towel bars, robe hooks,TP dispensers, shelves & other miscellaneous items)whether illustrated or not. 2. Refer to Plumbing drawings for fixture schedule. 3. See Electrical drawings for lighting information & req's. 4. Electrical receptacles, switches, & controls should notbe located higher than 48" measured from the top of thereceptacle box, and no less than 15" measured from thebottom of the receptacle box.See Section 1136A or G-1.1 for additional notes. 5. Install all Owner-provided appliances. 6. Tile at backspash/wainscot in kitchens shall beinstalled over cementitious backer units. Comply withTCNA Assembly W244C-11, with optional vaporretarder membrane. Tile backsplash to be 6" inBathrooms and to underside of upper cabinets inKitchens. 7. Tile at walls in other wet areas installed overcementitious backer units. Installation shall conformwith TCNA Assembly B415-11. 8. Provide door signal devices per Section 1132A.10. 9. All Interior Walls are Type XX U.N.O. 10. All Interior Doors are Type XX dimensioned with hingeside jamb 4" away from perpendicular wall U.N.O. 11. FLOOR PLAN KEYNOTESKitchen Sink. See Plumbing Drawings. Accessible Kitchen Sink with removable basecabinet below, meeting all requirements of Section1133A.3. Flooring shall continue underneath.Faucet controls meeting all requirements of Section1133A.3. See Plumbing Drawings. Range & Vent Hood O.F.C.I.See Mechanical Drawings . Refrigerator O.F.C.I. 36"W, Standard DepthDishwasher O.F.C.I. 1 1A234 Base Cabinet and Solid-surface Cabinet Top with TileSplash. Owner to select. See Casework Notes . 5 Upper Cabinets. See Casework Notes . 6 Lavatory. See Plumbing Drawings. 7 Accessible Lavatory with removable base cabinetbelow, meeting all requirements of Section 1134A.8.Flooring shall continue underneath. Faucet controlsmeeting all requirements of Section 1133A.3. SeePlumbing Drawings. 7A 30"x48" Clear Floor Space for accessibleappliances & fixtures. See Sheet G-1.2 . Floor-mounted Water Closet.See Plumbing Drawings. 8 Accessible Floor-mounted Water Closet meeting allrequirements of Section 1134A.7. 15" min. seatheight. 44" max. Water Closet controls above floor.5 lb. max. force to operate See Sheet G-1.2 . See Plumbing Drawings. 8A Shower with tile walls to ceiling and tile floor. Slopeshower floor to drain. See Plumbing Drawings. 9 Accessible Shower meeting all requirements ofSection 1134A.5&6. Tile walls to ceiling and tilefloor. Slope shower floor to drain. See Sheet G-1.2 . See Plumbing Drawings. 9A Bathtub. See Plumbing Drawings. 11 Jacuzzi Bathtub. See Plumbing Drawings. 12 Wall-mounted Mirror. 13 Frameless tempered glass Shower Enclosure/doors. 10 Recessed Medicine Cabinet. Cabinet Door withmirror, prefinished painted metal interior withadjustable shelves. 14 Side-by-Side Washer & Dryer, O.F.C.I. 15 Stacked Washer & Dryer, O.F.C.I. 16 GS Smitty Pan with drain under Washer & Dryer. 17 Automatic Washing Machine Water Shutoff Valvewith leak sensor: Intelliflow, Series A2C-M1. 18 Dryer Exhaust Vent Duct, min. 4" diameter, to theoutside, equipped with back-draft damper 19 Interior Stair. See Sheet A-9.6 for stair and handrail details. 21 Provide min. one layer of 5/8" gypsum board atusable underside of stairs. CBC 1009.5.3. 22 Closet rod and 16" shelf above. 23 Full-height linen cabinet. 24 Water heater on 18" high platform above floor. SeeMEP Drawings. Provide 2" galvanized steelrestarining straps to wall. 20 Balcony with approved weatherproof walkingsurface/deck coating system: Dex-O-Tex, or approvedequal, over plywood framing (see Structural Drawings ). Slope min. 1/4" per ft. along flow line. See Sheet A-9.4 for details. 25 Min. 42" high Guardrail. For Details, see: 26 Deck drain. Slope to drain. 27 Outline of Building above. 28 Outline of Roof or Balcony above. 29 Edge of soffit above. See Reflected Ceiling Plans. 30 Clerestory above. For Plans, see: 31 Internal Roof Drain/Overflow Drain. See Plumbing Drawings . Provide installation submittal under Section 075423 (Roofing) for Architect's review.Overflow Drains shall discharge above grade. 34 Type AA-9.41 Type B Type C A-9.44 A-9.47 Type A Type B Type C A-2.61 A-2.63 A-2.65 Clerestory Window above. See Sheet A-2.6 for Plans. 32 2"x4" Prefinished Metal Downspout to dischargeabove grade, typ. 35 Decorative Metal Screen. 36 Air Handling Unit. See Mechanical Drawings . 37 Skylight above. 33 Door Bell. 48" max. AFF andconnected to permanent wiring. 39 Floor Transition & Railing. See Detail 38 A-9.22 Space for Vertical Ductwork. 40 [Note intentionally left blank] 41 [Note intentionally left blank] 42 [Note intentionally left blank] 43 [Note intentionally left blank] 44 [Note intentionally left blank] 45 [Note intentionally left blank] 46 [Note intentionally left blank] 47 LEGENDSoffited Ceiling. See Reflected Ceiling Plansfor heights and details. Javier GonzalezNo. Cxxxxx Exp. x-xx-17 Robert G. TylerNo. C18812 Exp. 8-31-17 Date Reviewed Drawn ByDescription Do not scale drawings. Contractor shall verifyand be responsible for all dimensions andconditions on the site and Tyler Gonzalez Architects, Inc. shall be notified immediately ofany variations from the dimensions and conditions indicated on these drawings. Drawings, specifications, and other documents,including those in electronic form, prepared by the Architect and the Architect's consultants areInstruments of Service for use solely with respect to this Project. The Architect and theArchitect's consultants shall be deemed theauthors and owners of their respective Instruments of Service and shall retain all common law, statutory and other reserved rights, including copyrights. Visual contact withthese documents constitute prima faciaacceptance of these conditions.Architect of RecordIssue Dates Use of Architect's Drawings2015 Tyler Gonzalez Architects, Inc. c Sheet No.Project No.Scale 139 South Hudson Ave., Suite 300Pasadena, CA 91101626.396.9599 www.TGArchitects.netAs indicated A-2.2.A Checker Author 2015-09-3015-13 FLOOR PLANS - BUILDING C501 N. Santa Anita Ave. Arcadia, CA 91006 SANTA ANITA CONDOMINIUMS 1/4" = 1'-0" 2 First Floor Plan - Building C 1/4" = 1'-0" 1 Garage Floor Plan - Building C N No.DescriptionDate 17 14 F 15 16 2" / 1'-0" 1/2"/1 '-0"1/2"/1'-0 "1/2"/1 '-0"1/2"/1 '-0" 2"/1'-0" 1/2" / 1'-0" 2" / 1'-0" 535.91 535.91 4 A-4.0 536.17 3/8" / 1'-0" 3/8"/1'-0"3/8"/1'-0" 3/8"/1'-0"3/8"/1'-0" 3/8" / 1'-0"3/8" / 1'-0" 3/8"/1 '-0"3/8"/1'-0 " 3/8" / 1'-0"3/8" / 1'-0" 538.50 538.50 538.50 538.50 536.17 38' - 1 1/4" 26' - 2 3/4" 26' - 6" 4' - 1" 3' - 4 1/2" 10' - 7 17/32" 19' - 8 31/32" 3 1/4" 16' - 0 3/4" 2' - 1 1/2" 8' - 0 1/2" 8' - 0 1/2" 2' - 1 1/2" 16' - 4" 1' - 1 1/2" 18' - 7 1/2" 3 1/4" 18' - 8 3/4" 7' - 6" 7' - 6" 19' - 0" 9" 91' - 7" 2'-0"8'-5"12 '-101/4 "11'-63/4"3'-3" 2'-0"4"6'-03/4"10"12'-93/4"2'-93/4"7'-73/4" 2'-0"10'-33 /4"12'-63 /4"10'-8"1'-31/2"3'-3" 1' - 3" Typ . 2'-0" Typ. 2' - 0" Typ . 2'-0" Typ. 2' - 0" Typ. 2' - 0" 1' - 8" Typ . 2'-0" Typ . 2'-0" 2' - 2 1/4" 16' - 5 1/4" 8' - 9 3/8" 9' - 11 3/8" 10' - 9" 8' - 3" 4'-63/4"8'-31/2" 1'-01/4"11'-61/2 " 2'-113/4" A-2.61 A 36'-1" 1 A-4.2 5 A-4.0 56 53 51 55 Type A 57 57 57 57 57 56 53 50 55 57 Type C 51 58 54 54 54 54 58 51 55 Type A 53 53 50 56 58 52 55 Type A 1 1 1 54 55Type A58 50 53 56 51 50 53 2"/1'-0"2"/1'-0" 52 52 54 59 17 14 F 15 16 M. BEDRM. W.I.C. M. BATH BEDRM. 3 BATH CL STUDY BEDRM. 2 LINEN CL M. BATH 521.00 526.17 M. BEDRM. W.I.C. BATH LINEN CL BEDRM. 3 CL HALL 526.17 A-3.4.A1 A-3.4.A2 A-3.4.B 1 A-3.4.B 2 BEDRM. 2 4 A-4.0 UNIT 4 UNIT 5 UNIT 6 38' - 1 1/4" 26' - 2 3/4" 26' - 6" 4' - 1" 3' - 0 1/2" 4" 10' - 7 1/2" 19' - 9" 3 1/4" 16' - 0 3/4" 10' - 2" 10' - 2" 16' - 4" EQ EQ 7' - 10 3/4" 8' - 2" 2' - 0 1/8" 8' - 7 3/8" 3' - 4" 9' - 7" 6' - 10" 4' - 1" 15' - 1 1/2" 18' - 7 1/2" 19' - 0" 7' - 2 3/4" 3 1/4" 3 1/4" 7' - 2 3/4" 19' - 0" 9" 91' - 7" 6' - 2" 8' - 11 1/2" 11' - 9 1/2" 6' - 10" 5' - 9 1/2" 3' - 8" 9' - 6 1/2" EQ EQ EQ EQ 9' - 6 1/2" 3' - 8" 5' - 9 1/2" 2'-0"8'-5"12'-101/4"14'-93/4" 7'-73/4"7'-2"EQ EQ 2'-0" 1'-61/4"1'-13/4" 4"6'-103/4"15'-71/2"7'-73/4"4"1'-4"1'-3" EQEQ3'-43/8"4'-33/8"9'-71/2"6'-0" 6' - 9 1/2" 3' - 4 1/2" 3' - 4 1/2" 6' - 9 1/2" 2' - 0 1/8" A 36'-1" 1 A-4.2 5 A-4.0 Type A Type AM. BATH M. BEDRM. W.I.C. BATH LINEN CL BEDRM. 3 CLHALL BEDRM. 2 7A 7A 25 25 8 8 1 1 5 5 1 1 7A 7A 14 14 34 35 35 35 9 10 137 7 13 BALC. 26 Type A 12 29 1 5 5 16 3 3 9A9A 3A 16 17 3234 25 35 35 118 23 238 9 10 12 29 13 7 5 9 10 12 13 7 5 8 34 31 31 21 21 21 33 33 33 5 5 5 5 7 7 30 30 30 13 13 32 24 24 24 40 40 40 2323 23 23 2323 23 23 23 29 34 34 34 29 29 29 35 8 8 8 11 11 AB CDF E KEY PLAN Colorado Blvd. SantaAnitaBlvd. ROOF PLAN KEYNOTESCCRC-Applied Cool Roof, Firestone, TPO.Specified Class-A Built-Up RoofingTyp. Parapet. See detailRoof Drain / Overflow Drain. See Plumbing Drawings. Provide installation submittal under Section 075423(Plumbing) for Architect's review. Overflow drainsshall discharge above grade.Roof Eave. For Details, see:Line of Building Below 505153565558 A-9.54 Parapet & Roof Connection. See detail 54 A-9.57 Type A Type B Type C A-9.51 A-9.55 A-9.58 4"x6" Aluminum Gutter with Location of Downspoutbelow. 57 Standing Seam Metal Roof 52 Rooftop Air Conditioning Unit (screened or concealed) 59 FINISH LEGENDEngineered Wood Flooring O.F.C.I. FloorsF1 Carpet over pad O.F.C.I. F2 Porcelain Tile over fiber-cement backer units,complying with TCNA assembly F144-11, withwaterproof membrane O.F.C.I. F3 Polished Concrete F4 Eggshell Latex WallsW1 Low-Sheet Latex (Bath & Laundry) W2 (All painted 5/8" Type X gypsum wallboard)Typical base: 6" high, square, painted BaseB1 Porcelain Tile base installed over cementitious backerunits. Provide allowance of $8/sf (tile material only) B2 [No base] B3 Eggshell Latex CeilingsC1 Low-Sheet Latex (Bath & Laundry) C2 (All painted 5/8" Type X gypsum wallboard)PLAN GENERAL NOTESRefer to accessibility sheets (G-1 Series) for additionalinformation & requirements. 1. Install all bathroom accessor ies (towel bars, robe hooks,TP dispensers, shelves & other miscellaneous items)whether illustrated or not. 2. Refer to Plumbing drawings for fixture schedule. 3. See Electrical drawings for lighting information & req's. 4. Electrical receptacles, switches, & controls should notbe located higher than 48" measured from the top of thereceptacle box, and no less than 15" measured from thebottom of the receptacle box.See Section 1136A or G-1.1 for additional notes. 5. Install all Owner-provided appliances. 6. Tile at backspash/wainscot in kitchens shall beinstalled over cementitious backer units. Comply withTCNA Assembly W244C-11, with optional vaporretarder membrane. Tile backsplash to be 6" inBathrooms and to underside of upper cabinets inKitchens. 7. Tile at walls in other wet areas installed overcementitious backer units. Installation shall conformwith TCNA Assembly B415-11. 8. Provide door signal devices per Section 1132A.10. 9. All Interior Walls are Type XX U.N.O. 10. All Interior Doors are Type XX dimensioned with hingeside jamb 4" away from perpendicular wall U.N.O. 11. FLOOR PLAN KEYNOTESKitchen Sink. See Plumbing Drawings. Accessible Kitchen Sink with removable basecabinet below, meeting all requirements of Section1133A.3. Flooring shall continue underneath.Faucet controls meeting all requirements of Section1133A.3. See Plumbing Drawings. Range & Vent Hood O.F.C.I.See Mechanical Drawings . Refrigerator O.F.C.I. 36"W, Standard DepthDishwasher O.F.C.I. 1 1A234 Base Cabinet and Solid-surface Cabinet Top with TileSplash. Owner to select. See Casework Notes . 5 Upper Cabinets. See Casework Notes . 6 Lavatory. See Plumbing Drawings. 7 Accessible Lavatory with removable base cabinetbelow, meeting all requirements of Section 1134A.8.Flooring shall continue underneath. Faucet controlsmeeting all requirements of Section 1133A.3. SeePlumbing Drawings. 7A 30"x48" Clear Floor Space for accessibleappliances & fixtures. See Sheet G-1.2 . Floor-mounted Water Closet.See Plumbing Drawings. 8 Accessible Floor-mounted Water Closet meeting allrequirements of Section 1134A.7. 15" min. seatheight. 44" max. Water Closet controls above floor.5 lb. max. force to operate See Sheet G-1.2 . See Plumbing Drawings. 8A Shower with tile walls to ceiling and tile floor. Slopeshower floor to drain. See Plumbing Drawings. 9 Accessible Shower meeting all requirements ofSection 1134A.5&6. Tile walls to ceiling and tilefloor. Slope shower floor to drain. See Sheet G-1.2 . See Plumbing Drawings. 9A Bathtub. See Plumbing Drawings. 11 Jacuzzi Bathtub. See Plumbing Drawings. 12 Wall-mounted Mirror. 13 Frameless tempered glass Shower Enclosure/doors. 10 Recessed Medicine Cabinet. Cabinet Door withmirror, prefinished painted metal interior withadjustable shelves. 14 Side-by-Side Washer & Dryer, O.F.C.I. 15 Stacked Washer & Dryer, O.F.C.I. 16 GS Smitty Pan with drain under Washer & Dryer. 17 Automatic Washing Machine Water Shutoff Valvewith leak sensor: Intelliflow, Series A2C-M1. 18 Dryer Exhaust Vent Duct, min. 4" diameter, to theoutside, equipped with back-draft damper 19 Interior Stair. See Sheet A-9.6 for stair and handrail details. 21 Provide min. one layer of 5/8" gypsum board atusable underside of stairs. CBC 1009.5.3. 22 Closet rod and 16" shelf above. 23 Full-height linen cabinet. 24 Water heater on 18" high platform above floor. SeeMEP Drawings. Provide 2" galvanized steelrestarining straps to wall. 20 Balcony with approved weatherproof walkingsurface/deck coating system: Dex-O-Tex, or approvedequal, over plywood framing (see Structural Drawings ). Slope min. 1/4" per ft. along flow line. See Sheet A-9.4 for details. 25 Min. 42" high Guardrail. For Details, see: 26 Deck drain. Slope to drain. 27 Outline of Building above. 28 Outline of Roof or Balcony above. 29 Edge of soffit above. See Reflected Ceiling Plans. 30 Clerestory above. For Plans, see: 31 Internal Roof Drain/Overflow Drain. See Plumbing Drawings . Provide installation submittal under Section 075423 (Roofing) for Architect's review.Overflow Drains shall discharge above grade. 34 Type AA-9.41 Type B Type C A-9.44 A-9.47 Type A Type B Type C A-2.61 A-2.63 A-2.65 Clerestory Window above. See Sheet A-2.6 for Plans. 32 2"x4" Prefinished Metal Downspout to dischargeabove grade, typ. 35 Decorative Metal Screen. 36 Air Handling Unit. See Mechanical Drawings . 37 Skylight above. 33 Door Bell. 48" max. AFF andconnected to permanent wiring. 39 Floor Transition & Railing. See Detail 38 A-9.22 Space for Vertical Ductwork. 40 [Note intentionally left blank] 41 [Note intentionally left blank] 42 [Note intentionally left blank] 43 [Note intentionally left blank] 44 [Note intentionally left blank] 45 [Note intentionally left blank] 46 [Note intentionally left blank] 47 LEGENDSoffited Ceiling. See Reflected Ceiling Plansfor heights and details. Javier GonzalezNo. Cxxxxx Exp. x-xx-17 Robert G. TylerNo. C18812 Exp. 8-31-17 Date Reviewed Drawn ByDescription Do not scale drawings. Contractor shall verifyand be responsible for all dimensions andconditions on the site and Tyler Gonzalez Architects, Inc. shall be notified immediately ofany variations from the dimensions and conditions indicated on these drawings. Drawings, specifications, and other documents,including those in electronic form, prepared by the Architect and the Architect's consultants areInstruments of Service for use solely with respect to this Project. The Architect and theArchitect's consultants shall be deemed theauthors and owners of their respective Instruments of Service and shall retain all common law, statutory and other reserved rights, including copyrights. Visual contact withthese documents constitute prima faciaacceptance of these conditions.Architect of RecordIssue Dates Use of Architect's Drawings2015 Tyler Gonzalez Architects, Inc. c Sheet No.Project No.Scale 139 South Hudson Ave., Suite 300Pasadena, CA 91101626.396.9599 www.TGArchitects.netAs indicated A-2.2.B Checker Author 2015-09-3015-13 FLOOR PLANS - BUILDING C501 N. Santa Anita Ave. Arcadia, CA 91006 SANTA ANITA CONDOMINIUMS 1/4" = 1'-0" 2 Roof Plan - Building C 1/4" = 1'-0" 1 Second Floor Plan - Building C N No.DescriptionDate 21 18 F 19 20 GARAGE LAUNDRY GARAGE LAUNDRY GARAGE 505.92 505.92 505.92 A-3.5.A2 15'-103/4"20'-21/4" 26' - 6" 26' - 6" 26' - 6" 79' - 6" 6' - 6 1/2" 19' - 11 1/2" 20' - 3 1/2" 6' - 2 1/2" 6' - 2 1/2" 20' - 3 1/2" 9' - 11 1/2" 10' - 0" 10' - 0" 10' - 3 1/2" 10' - 0" 10' - 3 1/2" 3'-6"16'-81/4"15'-103/4" 3'-6" A W D WD LAUNDRY W D 37 37 37 3 17 17 17 3 3 3 3 3 20 20 20 20 20 21 18 F 19 20 KITCHENDINING LIVING ENTRY 511.17 KITCHENLIVING PWDR. ENTRY DINING 515.17 515.17 515.17 515.17 511.17 515.17 522.50 515.17 DINING KITCHENLIVING ENTRY PWDR. BALC.BALC. BALC. BALC.515.17 A-3.5.A A-3.5.B 1 A-3.5.B 2 A-3.5.A1 2 2 A-4.1 4 A-4.0 UNIT 7 UNIT 9 UNIT 879' - 6" 8' - 3" 18' - 3" 6" 18' - 6" 7' - 2 3/4" 3 1/4" 3 1/4" 7' - 2 3/4" 19' - 0" 4' - 4 1/2" 3' - 10 1/2" 8' - 1 1/2" 3' - 8" 6' - 5 1/2" 5' - 3 1/2" 3' - 8" 9' - 6 1/2" EQ EQ EQ EQ 9' - 6 1/2" 3' - 8" 5' - 9 1/2" 2'-0"10'-0"9'-81/4"16'-43/4 " EQ EQ9'-23/4"7'-2" 26' - 6" 26' - 6" 26' - 6" 11' - 8" 14' - 10" 6" 15' - 10" 10' - 2" 10' - 2" 16' - 4" EQ EQ EQ EQ 2' - 0" 5' - 7 1/2" 2' - 6 1/2" 2' - 6 1/2" 5' - 7 1/2" 2' - 0" 3' - 4 1/8" 5' - 0 1/2" 3' - 3 3/8" 7' - 7" 7' - 3" 7"5'-8" 9"1'-3"6'-3"24'-8"3'-11"1'-3" 12'-81/8"11'-117/8" 20 25 A 36'-1" 3 3 3 4 4 4 2 2 2 8 3 3 10 10 10 4 4 4 4 4 4 20 8 3 3 8 21 14 See Unit 5 See Unit 6 AB CDF E KEY PLAN Colorado Blvd. SantaAnitaBlvd. FLOOR PLAN KEYNOTESKitchen Sink. See Plumbing Drawings. Accessible Kitchen Sink with removable basecabinet below, meeting all requirements of Section1133A.3. Flooring shall continue underneath.Faucet controls meeting all requirements of Section1133A.3. See Plumbing Drawings. Range & Vent Hood O.F.C.I.See Mechanical Drawings . Refrigerator O.F.C.I. 36"W, Standard DepthDishwasher O.F.C.I. 1 1A234 Base Cabinet and Solid-surface Cabinet Top with TileSplash. Owner to select. See Casework Notes . 5 Upper Cabinets. See Casework Notes . 6 Lavatory. See Plumbing Drawings. 7 Accessible Lavatory with removable base cabinetbelow, meeting all requirements of Section 1134A.8.Flooring shall continue underneath. Faucet controlsmeeting all requirements of Section 1133A.3. SeePlumbing Drawings. 7A 30"x48" Clear Floor Space for accessibleappliances & fixtures. See Sheet G-1.2 . Floor-mounted Water Closet.See Plumbing Drawings. 8 Accessible Floor-mounted Water Closet meeting allrequirements of Section 1134A.7. 15" min. seatheight. 44" max. Water Closet controls above floor.5 lb. max. force to operate See Sheet G-1.2 . See Plumbing Drawings. 8A Shower with tile walls to ceiling and tile floor. Slopeshower floor to drain. See Plumbing Drawings. 9 Accessible Shower meeting all requirements ofSection 1134A.5&6. Tile walls to ceiling and tilefloor. Slope shower floor to drain. See Sheet G-1.2 . See Plumbing Drawings. 9A Bathtub. See Plumbing Drawings. 11 Jacuzzi Bathtub. See Plumbing Drawings. 12 Wall-mounted Mirror. 13 Frameless tempered glass Shower Enclosure/doors. 10 Recessed Medicine Cabinet. Cabinet Door withmirror, prefinished painted metal interior withadjustable shelves. 14 Side-by-Side Washer & Dryer, O.F.C.I. 15 Stacked Washer & Dryer, O.F.C.I. 16 GS Smitty Pan with drain under Washer & Dryer. 17 Automatic Washing Machine Water Shutoff Valvewith leak sensor: Intelliflow, Series A2C-M1. 18 Dryer Exhaust Vent Duct, min. 4" diameter, to theoutside, equipped with back-draft damper 19 Interior Stair. See Sheet A-9.6 for stair and handrail details. 21 Provide min. one layer of 5/8" gypsum board atusable underside of stairs. CBC 1009.5.3. 22 Closet rod and 16" shelf above. 23 Full-height linen cabinet. 24 Water heater on 18" high platform above floor. SeeMEP Drawings. Provide 2" galvanized steelrestarining straps to wall. 20 Balcony with approved weatherproof walkingsurface/deck coating system: Dex-O-Tex, or approvedequal, over plywood framing (see Structural Drawings ). Slope min. 1/4" per ft. along flow line. See Sheet A-9.4 for details. 25 Min. 42" high Guardrail. For Details, see: 26 Deck drain. Slope to drain. 27 Outline of Building above. 28 Outline of Roof or Balcony above. 29 Edge of soffit above. See Reflected Ceiling Plans. 30 Clerestory above. For Plans, see: 31 Internal Roof Drain/Overflow Drain. See Plumbing Drawings . Provide installation submittal under Section 075423 (Roofing) for Architect's review.Overflow Drains shall discharge above grade. 34 Type AA-9.41 Type B Type C A-9.44 A-9.47 Type A Type B Type C A-2.61 A-2.63 A-2.65 Clerestory Window above. See Sheet A-2.6 for Plans. 32 2"x4" Prefinished Metal Downspout to dischargeabove grade, typ. 35 Decorative Metal Screen. 36 Air Handling Unit. See Mechanical Drawings . 37 Skylight above. 33 Door Bell. 48" max. AFF andconnected to permanent wiring. 39 Floor Transition & Railing. See Detail 38 A-9.22 Space for Vertical Ductwork. 40 [Note intentionally left blank] 41 [Note intentionally left blank] 42 [Note intentionally left blank] 43 [Note intentionally left blank] 44 [Note intentionally left blank] 45 [Note intentionally left blank] 46 [Note intentionally left blank] 47 LEGENDSoffited Ceiling. See Reflected Ceiling Plansfor heights and details. Javier GonzalezNo. Cxxxxx Exp. x-xx-17 Robert G. TylerNo. C18812 Exp. 8-31-17 Date Reviewed Drawn ByDescription Do not scale drawings. Contractor shall verifyand be responsible for all dimensions andconditions on the site and Tyler Gonzalez Architects, Inc. shall be notified immediately ofany variations from the dimensions and conditions indicated on these drawings. Drawings, specifications, and other documents,including those in electronic form, prepared by the Architect and the Architect's consultants areInstruments of Service for use solely with respect to this Project. The Architect and theArchitect's consultants shall be deemed theauthors and owners of their respective Instruments of Service and shall retain all common law, statutory and other reserved rights, including copyrights. Visual contact withthese documents constitute prima faciaacceptance of these conditions.Architect of RecordIssue Dates Use of Architect's Drawings2015 Tyler Gonzalez Architects, Inc. c Sheet No.Project No.Scale 139 South Hudson Ave., Suite 300Pasadena, CA 91101626.396.9599 www.TGArchitects.netAs indicated A-2.3.A Checker Author 2015-09-3015-13 FLOOR PLANS - BUILDING D501 N. Santa Anita Ave. Arcadia, CA 91006 SANTA ANITA CONDOMINIUMS 1/4" = 1'-0" 1 Garage Floor Plan - Building D 1/4" = 1'-0" 2 First Floor Plan - Building D N No.DescriptionDate 1/4" = 1'-0"Floor Plan Key Notes 21 18 F 19 20 1/2"/1'-0"1/2"/1'-0"1/2"/1'-0 "1/2"/1'-0" 1/2"/1'-0"1/2"/1'-0" 535.91 535.91 535.91 3/8"/1'-0"3/8"/1'-0" 3/8" / 1'-0"3/8" / 1'-0" 3/8"/1 '-0"3/8"/1'-0 " 3/8" / 1'-0"3/8" / 1'-0" 538.50 538.50 538.50 538.50 3/8"/1'-0"3/8"/1'-0" 3/8" / 1'-0" 538.50 A-2.61 79' - 6" 7' - 5 1/8" 3' - 5 7/8" 14' - 10" 6" 18' - 6" 7' - 6" 7' - 6" 19' - 0" 9" 5' - 8 1/16" 9' - 1 15/16" 8' - 9 7/16" 9' - 8 9/16" 10' - 9" 8' - 3" 2'-0"8'-5"12'-101/4"11'-63 /4"3'-3" 26' - 6" 26' - 6" 26' - 6" 9" 10' - 11" 14' - 10" 6" 15' - 10" 2' - 1 1/2" 8' - 0 1/2" 8' - 0 1/2" 2' - 1 1/2" 16' - 4" 9" 1'-3" 1'-3"10'-81/2"12'-63/4"9'-03/4"1'-3"1'-3" 9" 10'-33/4"12'-63 /4"10'-81/2 "1'-3"2'-0" 8'-31/2"4'-63/4" A 36'-1" 1 1 1 50 53 51 55 56 53 50 58 51 55 50 53 56 5155 50 58 51 55 56 53 50 58 51 55 505558 54 54 54 54 56 21 18 F 19 20 A-3.5.A A-3.5.B 1 A-3.5.B 2 A-3.5.A1 2 M. BEDRM. M. BATH W.I.C.HALL BATH BEDRM. 3 CL CL BEDRM. 2 LINEN M. BEDRM. M. BATH W.I.C.HALL BATH BEDRM. 2 CL CL BEDRM. 3 LINEN M. BEDRM. M. BATH HALLW.I.C. BATH BEDRM. 3 CL BEDRM. 2 CL LINEN 526.17 526.17 526.17 2 A-4.1 4 A-4.0 UNIT 7 UNIT 9 UNIT 879' - 6" 9" 7' - 6" 18' - 3" 6" 18' - 6" 7' - 2 3/4" 3 1/4" 3 1/4" 7' - 2 3/4" 19' - 0" 3' - 7 1/2" 3' - 10 1/2" 8' - 1 1/2" 3' - 8" 6' - 5 1/2" 5' - 3 1/2" 3' - 8" 9' - 6 1/2" EQ EQ EQ EQ 9' - 6 1/2" 3' - 8" 5' - 9 1/2" 2'-0"8'-5"12'-101 /4"14'-93 /4" EQEQ7'-73/4"7'-2" 26' - 6" 26' - 6" 26' - 6" 9" 10' - 11" 14' - 10" 6" 15' - 10" 10' - 2" 10' - 2" 16' - 4" EQ EQ EQ EQ 7' - 3 1/2" 7' - 7" 7' - 3" 9" 1'-3" 1'-3"10'-81/2"21'-71/2"1'-3" 1'-3" 2'-31/4"8'-51/4"6'-33/8"6'-33/8"6'-91/2"2'-31/4" 7" 91/8 " 6' - 9 1/2" 3' - 4 1/2" 3' - 4 1/2" 6' - 9 1/2" 3' - 7 1/2" A 36'-1" A-2.61 33 33 33 2 2 2 2 2 2 2 2 5 1 1 2 2 2 2 2 2 22 1 1 2 2 2 2 2 2 1 2 5 1 2 8A 7A 8A 7A13 14 14 7A 7A 7A 7A 7 7 8 8 25 25 5 8A 9 8A AB CDF E KEY PLAN Colorado Blvd. SantaAnitaBlvd. ROOF PLAN KEYNOTESCCRC-Applied Cool Roof, Firestone, TPO.Specified Class-A Built-Up RoofingTyp. Parapet. See detailRoof Drain / Overflow Drain. See Plumbing Drawings. Provide installation submittal under Section 075423(Plumbing) for Architect's review. Overflow drainsshall discharge above grade.Roof Eave. For Details, see:Line of Building Below 505153565558 A-9.54 Parapet & Roof Connection. See detail 54 A-9.57 Type A Type B Type C A-9.51 A-9.55 A-9.58 4"x6" Aluminum Gutter with Location of Downspoutbelow. 57 Standing Seam Metal Roof 52 Rooftop Air Conditioning Unit (screened or concealed) 59 FLOOR PLAN KEYNOTESKitchen Sink. See Plumbing Drawings. Accessible Kitchen Sink with removable basecabinet below, meeting all requirements of Section1133A.3. Flooring shall continue underneath.Faucet controls meeting all requirements of Section1133A.3. See Plumbing Drawings. Range & Vent Hood O.F.C.I.See Mechanical Drawings . Refrigerator O.F.C.I. 36"W, Standard DepthDishwasher O.F.C.I. 1 1A234 Base Cabinet and Solid-surface Cabinet Top with TileSplash. Owner to select. See Casework Notes . 5 Upper Cabinets. See Casework Notes . 6 Lavatory. See Plumbing Drawings. 7 Accessible Lavatory with removable base cabinetbelow, meeting all requirements of Section 1134A.8.Flooring shall continue underneath. Faucet controlsmeeting all requirements of Section 1133A.3. SeePlumbing Drawings. 7A 30"x48" Clear Floor Space for accessibleappliances & fixtures. See Sheet G-1.2 . Floor-mounted Water Closet.See Plumbing Drawings. 8 Accessible Floor-mounted Water Closet meeting allrequirements of Section 1134A.7. 15" min. seatheight. 44" max. Water Closet controls above floor.5 lb. max. force to operate See Sheet G-1.2 . See Plumbing Drawings. 8A Shower with tile walls to ceiling and tile floor. Slopeshower floor to drain. See Plumbing Drawings. 9 Accessible Shower meeting all requirements ofSection 1134A.5&6. Tile walls to ceiling and tilefloor. Slope shower floor to drain. See Sheet G-1.2 . See Plumbing Drawings. 9A Bathtub. See Plumbing Drawings. 11 Jacuzzi Bathtub. See Plumbing Drawings. 12 Wall-mounted Mirror. 13 Frameless tempered glass Shower Enclosure/doors. 10 Recessed Medicine Cabinet. Cabinet Door withmirror, prefinished painted metal interior withadjustable shelves. 14 Side-by-Side Washer & Dryer, O.F.C.I. 15 Stacked Washer & Dryer, O.F.C.I. 16 GS Smitty Pan with drain under Washer & Dryer. 17 Automatic Washing Machine Water Shutoff Valvewith leak sensor: Intelliflow, Series A2C-M1. 18 Dryer Exhaust Vent Duct, min. 4" diameter, to theoutside, equipped with back-draft damper 19 Interior Stair. See Sheet A-9.6 for stair and handrail details. 21 Provide min. one layer of 5/8" gypsum board atusable underside of stairs. CBC 1009.5.3. 22 Closet rod and 16" shelf above. 23 Full-height linen cabinet. 24 Water heater on 18" high platform above floor. SeeMEP Drawings. Provide 2" galvanized steelrestarining straps to wall. 20 Balcony with approved weatherproof walkingsurface/deck coating system: Dex-O-Tex, or approvedequal, over plywood framing (see Structural Drawings ). Slope min. 1/4" per ft. along flow line. See Sheet A-9.4 for details. 25 Min. 42" high Guardrail. For Details, see: 26 Deck drain. Slope to drain. 27 Outline of Building above. 28 Outline of Roof or Balcony above. 29 Edge of soffit above. See Reflected Ceiling Plans. 30 Clerestory above. For Plans, see: 31 Internal Roof Drain/Overflow Drain. See Plumbing Drawings . Provide installation submittal under Section 075423 (Roofing) for Architect's review.Overflow Drains shall discharge above grade. 34 Type AA-9.41 Type B Type C A-9.44 A-9.47 Type A Type B Type C A-2.61 A-2.63 A-2.65 Clerestory Window above. See Sheet A-2.6 for Plans. 32 2"x4" Prefinished Metal Downspout to dischargeabove grade, typ. 35 Decorative Metal Screen. 36 Air Handling Unit. See Mechanical Drawings . 37 Skylight above. 33 Door Bell. 48" max. AFF andconnected to permanent wiring. 39 Floor Transition & Railing. See Detail 38 A-9.22 Space for Vertical Ductwork. 40 [Note intentionally left blank] 41 [Note intentionally left blank] 42 [Note intentionally left blank] 43 [Note intentionally left blank] 44 [Note intentionally left blank] 45 [Note intentionally left blank] 46 [Note intentionally left blank] 47 LEGENDSoffited Ceiling. See Reflected Ceiling Plansfor heights and details. Javier GonzalezNo. Cxxxxx Exp. x-xx-17 Robert G. TylerNo. C18812 Exp. 8-31-17 Date Reviewed Drawn ByDescription Do not scale drawings. Contractor shall verifyand be responsible for all dimensions andconditions on the site and Tyler Gonzalez Architects, Inc. shall be notified immediately ofany variations from the dimensions and conditions indicated on these drawings. Drawings, specifications, and other documents,including those in electronic form, prepared by the Architect and the Architect's consultants areInstruments of Service for use solely with respect to this Project. The Architect and theArchitect's consultants shall be deemed theauthors and owners of their respective Instruments of Service and shall retain all common law, statutory and other reserved rights, including copyrights. Visual contact withthese documents constitute prima faciaacceptance of these conditions.Architect of RecordIssue Dates Use of Architect's Drawings2015 Tyler Gonzalez Architects, Inc. c Sheet No.Project No.Scale 139 South Hudson Ave., Suite 300Pasadena, CA 91101626.396.9599 www.TGArchitects.netAs indicated A-2.3.B Checker Author 2015-09-3015-13 FOOR PLANS - BUILDING D501 N. Santa Anita Ave. Arcadia, CA 91006 SANTA ANITA CONDOMINIUMS 1/4" = 1'-0" 2 Roof Plan - Building D 1/4" = 1'-0" 1 Second Floor Plan - Building D N No.DescriptionDate 1/4" = 1'-0"Floor Plan Key Notes 22 23 EB CD GARAGEGARAGEGARAGEGARAGE 505.92505.92505.92505.92 A-3.6.A1 A-3.6.A2 A-3.6.B 1 A-3.6.A 3 WD 4 A-4.1 27'-1"22'-2"22'-2"22'-2" 4'-11"22'-2" 11'-1 "11'-1 "EQ EQ EQEQEQEQ 33' - 7 1/8" 10' - 4 3/8" 18' - 0" 7 5/8" 4' - 9 3/8" 3' - 2 1/8" 7' - 0" 33' - 7 1/8" 10' - 4 3/8" 17' - 0" 7 5/8" 5' - 9 3/8" 10' - 2 1/8" 4'-11 "9'-011/16"8'-71/8"4'-63/16"17'-73 /4"4'-61/4"4'-61/4"17'-73/4"17'-51 /8"4'-87/8" LAUNDRY A 93'-7" 37 17171717 3333 3 20 202020 22 23 EB CD CL ENTRY LIVING KITCHEN DINING PWDR. KITCHEN DINING CL PWDR. ENTRYCL 515.17515.17 510.58 LIVING DINING CL PWDR. ENTRYCL KITCHEN BATH 1 BEDRM. 1 CL CL KITCHEN DINING LIVING ENTRY HALL BALC.515.17 515.17BALC.515.17 515.17515.17 510.58 510.58 LIVING A-3.6.A1 A-3.6.A2 A-3.6.B 1 A-3.6.B 2 A-3.6.A 3 4 A-4.04 A-4.1 BALC. UNIT 10UNIT 11UNIT 12UNIT 13 14'-101/2"4'-101/4"7'-1"31/4"14'-10"7'-4"7'-4"14'-10"31/4"15'-43/4"6'-6" 45' - 11 1/2" 1' - 0"1' - 0" 27' - 8 1/4" 16' - 3 1/4" 6 ' - 2 1/2" 1 4' - 0" 1 '- 2 " EQ EQ 8' - 6" 14' - 4" 4' - 10 1/4" 21' - 4 1 /2" 27'-1"22'-2"22'-2"22'-2" 16'-10"9'-113/4"31/4"14'-8"7'-23/4"31/4"31/4"7'-23/4"14'-8"31/4"16'-43/4"5'-6" 5'-33/4"3'-8"3'-8"3'-9"6'-21/2"3'-8"4'-91/2"EQ EQEQEQ4'-91/2"3'-8"6'-21/2"EQEQ6'-4"10'-6" EQEQ7'-33/8"7'-65/8"2'-8"4'-8"4'-8"2'-8"7'-65/8"7'-33/8"7'-03/4"8'-4"2'-6"4'-0" 1' - 0"1' - 0" 8' - 9" 31' - 2 1/2" 2' - 9" 1' - 3" 2' - 0" 7" 6' - 11 1/2"5' - 2" 3' - 7" 6' - 9" 5' - 4" 10' - 3" 5' - 4" 3' - 6 1/2" 43' - 11 1/2" A 93'-7" 3 33 3 4 44 4 8 2 2 2 10 2 2 10 8 2 2 2 10 2 2 5 2 20 11 6 8 8 3 444 4444 33 2020 12 SeeUnit11 3 4' - 2" 3' - 4" 3 3 21 6 AB CDF E KEY PLAN Colorado Blvd. SantaAnitaBlvd. FLOOR PLAN KEYNOTESKitchen Sink. See Plumbing Drawings. Accessible Kitchen Sink with removable basecabinet below, meeting all requirements of Section1133A.3. Flooring shall continue underneath.Faucet controls meeting all requirements of Section1133A.3. See Plumbing Drawings. Range & Vent Hood O.F.C.I.See Mechanical Drawings . Refrigerator O.F.C.I. 36"W, Standard DepthDishwasher O.F.C.I. 1 1A234 Base Cabinet and Solid-surface Cabinet Top with TileSplash. Owner to select. See Casework Notes . 5 Upper Cabinets. See Casework Notes . 6 Lavatory. See Plumbing Drawings. 7 Accessible Lavatory with removable base cabinetbelow, meeting all requirements of Section 1134A.8.Flooring shall continue underneath. Faucet controlsmeeting all requirements of Section 1133A.3. SeePlumbing Drawings. 7A 30"x48" Clear Floor Space for accessibleappliances & fixtures. See Sheet G-1.2 . Floor-mounted Water Closet.See Plumbing Drawings. 8 Accessible Floor-mounted Water Closet meeting allrequirements of Section 1134A.7. 15" min. seatheight. 44" max. Water Closet controls above floor.5 lb. max. force to operate See Sheet G-1.2 . See Plumbing Drawings. 8A Shower with tile walls to ceiling and tile floor. Slopeshower floor to drain. See Plumbing Drawings. 9 Accessible Shower meeting all requirements ofSection 1134A.5&6. Tile walls to ceiling and tilefloor. Slope shower floor to drain. See Sheet G-1.2 . See Plumbing Drawings. 9A Bathtub. See Plumbing Drawings. 11 Jacuzzi Bathtub. See Plumbing Drawings. 12 Wall-mounted Mirror. 13 Frameless tempered glass Shower Enclosure/doors. 10 Recessed Medicine Cabinet. Cabinet Door withmirror, prefinished painted metal interior withadjustable shelves. 14 Side-by-Side Washer & Dryer, O.F.C.I. 15 Stacked Washer & Dryer, O.F.C.I. 16 GS Smitty Pan with drain under Washer & Dryer. 17 Automatic Washing Machine Water Shutoff Valvewith leak sensor: Intelliflow, Series A2C-M1. 18 Dryer Exhaust Vent Duct, min. 4" diameter, to theoutside, equipped with back-draft damper 19 Interior Stair. See Sheet A-9.6 for stair and handrail details. 21 Provide min. one layer of 5/8" gypsum board atusable underside of stairs. CBC 1009.5.3. 22 Closet rod and 16" shelf above. 23 Full-height linen cabinet. 24 Water heater on 18" high platform above floor. SeeMEP Drawings. Provide 2" galvanized steelrestarining straps to wall. 20 Balcony with approved weatherproof walkingsurface/deck coating system: Dex-O-Tex, or approvedequal, over plywood framing (see Structural Drawings ). Slope min. 1/4" per ft. along flow line. See Sheet A-9.4 for details. 25 Min. 42" high Guardrail. For Details, see: 26 Deck drain. Slope to drain. 27 Outline of Building above. 28 Outline of Roof or Balcony above. 29 Edge of soffit above. See Reflected Ceiling Plans. 30 Clerestory above. For Plans, see: 31 Internal Roof Drain/Overflow Drain. See Plumbing Drawings . Provide installation submittal under Section 075423 (Roofing) for Architect's review.Overflow Drains shall discharge above grade. 34 Type AA-9.41 Type B Type C A-9.44 A-9.47 Type A Type B Type C A-2.61 A-2.63 A-2.65 Clerestory Window above. See Sheet A-2.6 for Plans. 32 2"x4" Prefinished Metal Downspout to dischargeabove grade, typ. 35 Decorative Metal Screen. 36 Air Handling Unit. See Mechanical Drawings . 37 Skylight above. 33 Door Bell. 48" max. AFF andconnected to permanent wiring. 39 Floor Transition & Railing. See Detail 38 A-9.22 Space for Vertical Ductwork. 40 [Note intentionally left blank] 41 [Note intentionally left blank] 42 [Note intentionally left blank] 43 [Note intentionally left blank] 44 [Note intentionally left blank] 45 [Note intentionally left blank] 46 [Note intentionally left blank] 47 LEGENDSoffited Ceiling. See Reflected Ceiling Plansfor heights and details. Javier GonzalezNo. Cxxxxx Exp. x-xx-17 Robert G. TylerNo. C18812 Exp. 8-31-17 Date Reviewed Drawn ByDescription Do not scale drawings. Contractor shall verifyand be responsible for all dimensions andconditions on the site and Tyler Gonzalez Architects, Inc. shall be notified immediately ofany variations from the dimensions and conditions indicated on these drawings. Drawings, specifications, and other documents,including those in electronic form, prepared by the Architect and the Architect's consultants areInstruments of Service for use solely with respect to this Project. The Architect and theArchitect's consultants shall be deemed theauthors and owners of their respective Instruments of Service and shall retain all common law, statutory and other reserved rights, including copyrights. Visual contact withthese documents constitute prima faciaacceptance of these conditions.Architect of RecordIssue Dates Use of Architect's Drawings2015 Tyler Gonzalez Architects, Inc. c Sheet No.Project No.Scale 139 South Hudson Ave., Suite 300Pasadena, CA 91101626.396.9599 www.TGArchitects.netAs indicated A-2.4.A Checker Author 2015-09-3015-13 FLOOR PLANS - BUILDING E501 N. Santa Anita Ave. Arcadia, CA 91006 SANTA ANITA CONDOMINIUMS 1/4" = 1'-0" 1 Garage Floor Plan - Building E 1/4" = 1'-0" 2 First Floor Plan - Building E N No.DescriptionDate 1/4" = 1'-0"Floor Plan Key Notes 22 23 EB CD 1/2" / 1'-0" 1/2" / 1'-0" 1/2"/1'-0" 1/2" / 1'-0" 1/2" / 1'-0" 1/2" / 1'-0" 1/2" / 1'-0" 1/2" / 1'-0" 1/2" / 1'-0" 1/2" / 1'-0" 535.91 3/8"/1'-0" 3/8" / 1'-0" 3/8" / 1'-0" 3/8"/1'-0" 535.91 3/8"/1'-0" 3/8"/1'-0" 3/8" / 1'-0" 3/8" / 1'-0" 538.50538.50 538.50538.50 A-2.63 15'-01/4"11'-91/2"31/4"14'-10"7'-4"7'-4"14'-10"31/4"21'-103/4" 45' - 11 1/2" 27'-1"22'-2"22'-2"22'-2" 16'-10"9'-113/4"31/4"14'-8"7'-6"7'-6"14'-8"31/4"21'-103/4" 1' - 0"1' - 0" 41' - 11 1/2" 9" 1' - 3" Typ. 1' - 11 7/8" 43' - 11 1/2" 6 '- 5 " 1 3' - 4" 1 '- 9 " 21'- 6" 1' - 0"1' - 0" 18' - 0" 9' - 8 1/4" 15' - 0 1/4" 1' - 3" 10" 12' - 6" 13' - 4" Typ . 2'-0" Typ. 2' - 0" 1' - 0" 24' - 6 1/4" 10' - 5 1/4" 7' - 0" 2' - 0" 1' - 3" Typ.2'- 0" Ty p. 2' - 0" 2' - 0"3' - 0" Typ . 2'-0" Typ. 2' - 0" Typ.2'- 0" UNIT 10UNIT 11UNIT 12UNIT 13A 93'-7 " 2' - 0" 2"/ 1'-0" 2 "/ 1'-0" 2"/ 1'-0" 2 "/ 1'-0" 555158 55515856505550535650585155 585155565350 585255 555158 51 54515556535058 54 54 54 59595959 22 23 EB CD BEDRM. 3 CL BEDRM. 2 CL HALL LAUNDRY M. BEDRM. W.I.C. M. BATH HALL BATHLINEN CL BEDRM. 2 CL HALL LAUNDRY M. BEDRM. W.I.C. M. BATH HALL BATHLINEN BEDRM. 3 CL BEDRM. 2 CL HALL LAUNDRY W.I.C. M. BATH HALL BATHLINEN BEDRM. 3 526.17526.17526.17526.17 BATH HALL LINEN CL BEDRM. 3 W.I.C. CLBEDRM. 2 M. BATH M. BEDRM. A-3.6.A1 A-3.6.A2 A-3.6.B 1 A-3.6.B 2 A-3.6.A 3 W&DW&DW&D 4 A-4.04 A-4.1 15'-01/4"11'-91/2"31/4"14'-10 "7'-4"7'-4"14'-10"31 /4"15'-43 /4"6'-6" 45' - 11 1/2" 1' - 0"1' - 0" 18' - 0" 9' - 8 1/4" 16' - 3 1/4" EQ EQ 8' - 6" 9' - 6" EQ 3' - 10 1/2" EQ 27'-1 "22'-2"22'-2"22'-2 " 16'-10 "9'-113/4 "31 /4"14'-8"7'-23/4"31/4"31/4"7'-23/4"14'-8 "31/4 "16'-43/4"5'-6" 5'-33/4"3'-8"3'-8"3'-9"EQEQEQEQ 6'-4"10'-6" 7'-33/8"7'-65/8"3'-10"3'-6"3'-6"3'-10"7'-65/8"7'-33/8"7'-03/4"8'-4"3'-0"3'-6" 1' - 0"1' - 0" 41' - 11 1/2" 9" 1' - 3" 1' - 1 1/8"10 7/8" 1' - 10" 8' - 2" 8' - 2" 11' - 5 1/2" 12' - 4" 43' - 11 1/2" 6 '- 1 " 1 4' - 0" 1 '- 2 " 21' - 3" 2' - 1 1" 3' - 2" M. BEDRM. A 93'-7" A-2.63 11A 2 1 2 22 1 2 4 11A 2 2 1 2 2 22 1 2 5 4 2 2 1 2 2 22 1 2 5 4 2 2 1 2 1 2 5 2 22 11 33 3 3 8 13 16 3 777 3 3 1414 7A7A7A7A 33 25 2 5 26 5'-3"3'-8"2'-101/2" 6'-21/2"3'-8"4'-91/2"5'-03/4"3'-8"6'-21/2"EQEQ UNIT 10UNIT 11UNIT 12UNIT 13 3 3 11 AB CDF E KEY PLAN Colorado Blvd. SantaAnitaBlvd. FLOOR PLAN KEYNOTESKitchen Sink. See Plumbing Drawings. Accessible Kitchen Sink with removable basecabinet below, meeting all requirements of Section1133A.3. Flooring shall continue underneath.Faucet controls meeting all requirements of Section1133A.3. See Plumbing Drawings. Range & Vent Hood O.F.C.I.See Mechanical Drawings . Refrigerator O.F.C.I. 36"W, Standard DepthDishwasher O.F.C.I. 1 1A234 Base Cabinet and Solid-surface Cabinet Top with TileSplash. Owner to select. See Casework Notes . 5 Upper Cabinets. See Casework Notes . 6 Lavatory. See Plumbing Drawings. 7 Accessible Lavatory with removable base cabinetbelow, meeting all requirements of Section 1134A.8.Flooring shall continue underneath. Faucet controlsmeeting all requirements of Section 1133A.3. SeePlumbing Drawings. 7A 30"x48" Clear Floor Space for accessibleappliances & fixtures. See Sheet G-1.2 . Floor-mounted Water Closet.See Plumbing Drawings. 8 Accessible Floor-mounted Water Closet meeting allrequirements of Section 1134A.7. 15" min. seatheight. 44" max. Water Closet controls above floor.5 lb. max. force to operate See Sheet G-1.2 . See Plumbing Drawings. 8A Shower with tile walls to ceiling and tile floor. Slopeshower floor to drain. See Plumbing Drawings. 9 Accessible Shower meeting all requirements ofSection 1134A.5&6. Tile walls to ceiling and tilefloor. Slope shower floor to drain. See Sheet G-1.2 . See Plumbing Drawings. 9A Bathtub. See Plumbing Drawings. 11 Jacuzzi Bathtub. See Plumbing Drawings. 12 Wall-mounted Mirror. 13 Frameless tempered glass Shower Enclosure/doors. 10 Recessed Medicine Cabinet. Cabinet Door withmirror, prefinished painted metal interior withadjustable shelves. 14 Side-by-Side Washer & Dryer, O.F.C.I. 15 Stacked Washer & Dryer, O.F.C.I. 16 GS Smitty Pan with drain under Washer & Dryer. 17 Automatic Washing Machine Water Shutoff Valvewith leak sensor: Intelliflow, Series A2C-M1. 18 Dryer Exhaust Vent Duct, min. 4" diameter, to theoutside, equipped with back-draft damper 19 Interior Stair. See Sheet A-9.6 for stair and handrail details. 21 Provide min. one layer of 5/8" gypsum board atusable underside of stairs. CBC 1009.5.3. 22 Closet rod and 16" shelf above. 23 Full-height linen cabinet. 24 Water heater on 18" high platform above floor. SeeMEP Drawings. Provide 2" galvanized steelrestarining straps to wall. 20 Balcony with approved weatherproof walkingsurface/deck coating system: Dex-O-Tex, or approvedequal, over plywood framing (see Structural Drawings ). Slope min. 1/4" per ft. along flow line. See Sheet A-9.4 for details. 25 Min. 42" high Guardrail. For Details, see: 26 Deck drain. Slope to drain. 27 Outline of Building above. 28 Outline of Roof or Balcony above. 29 Edge of soffit above. See Reflected Ceiling Plans. 30 Clerestory above. For Plans, see: 31 Internal Roof Drain/Overflow Drain. See Plumbing Drawings . Provide installation submittal under Section 075423 (Roofing) for Architect's review.Overflow Drains shall discharge above grade. 34 Type AA-9.41 Type B Type C A-9.44 A-9.47 Type A Type B Type C A-2.61 A-2.63 A-2.65 Clerestory Window above. See Sheet A-2.6 for Plans. 32 2"x4" Prefinished Metal Downspout to dischargeabove grade, typ. 35 Decorative Metal Screen. 36 Air Handling Unit. See Mechanical Drawings . 37 Skylight above. 33 Door Bell. 48" max. AFF andconnected to permanent wiring. 39 Floor Transition & Railing. See Detail 38 A-9.22 Space for Vertical Ductwork. 40 [Note intentionally left blank] 41 [Note intentionally left blank] 42 [Note intentionally left blank] 43 [Note intentionally left blank] 44 [Note intentionally left blank] 45 [Note intentionally left blank] 46 [Note intentionally left blank] 47 LEGENDSoffited Ceiling. See Reflected Ceiling Plansfor heights and details. Javier GonzalezNo. Cxxxxx Exp. x-xx-17 Robert G. TylerNo. C18812 Exp. 8-31-17 Date Reviewed Drawn ByDescription Do not scale drawings. Contractor shall verifyand be responsible for all dimensions andconditions on the site and Tyler Gonzalez Architects, Inc. shall be notified immediately ofany variations from the dimensions and conditions indicated on these drawings. Drawings, specifications, and other documents,including those in electronic form, prepared by the Architect and the Architect's consultants areInstruments of Service for use solely with respect to this Project. The Architect and theArchitect's consultants shall be deemed theauthors and owners of their respective Instruments of Service and shall retain all common law, statutory and other reserved rights, including copyrights. Visual contact withthese documents constitute prima faciaacceptance of these conditions.Architect of RecordIssue Dates Use of Architect's Drawings2015 Tyler Gonzalez Architects, Inc. c Sheet No.Project No.Scale 139 South Hudson Ave., Suite 300Pasadena, CA 91101626.396.9599 www.TGArchitects.netAs indicated A-2.4.B Checker Author 2015-09-3015-13 FLOOR PLANS - BUILDING E501 N. Santa Anita Ave. Arcadia, CA 91006 SANTA ANITA CONDOMINIUMS 1/4" = 1'-0" 2 Roof Plan - Building E 1/4" = 1'-0" 1 Second Floor Plan - Building E N No.DescriptionDate 1/4" = 1'-0"Floor Plan Key Notes 13 GH 9 10 11 12 505.92 505.92 GARAGE A-3.7.A1 A-3.7.B2 505.92 505.92 LAUNDRY CL GARAGE LAUNDRY CL GARAGE LAUNDRY CL GARAGE LAUNDRY M ATCH LIN E 2 A-4.1 3 A-4.1 27' - 6" 27' - 6" 27' - 6" 27' - 6" 21' - 3 1/2" 6' - 2 1/2" 6' - 2 1/2" 21' - 3 1/2" 21' - 3 1/2" 6' - 2 1/2" 6' - 2 1/2" 21' - 3 1/2" 4" 110' - 4" 10' - 5 3/4" 10' - 9 3/4" 10' - 9 3/4" 10' - 5 3/4" 10' - 5 3/4" 10' - 9 3/4" EQ EQ 19'-55 /8"85/8 "15'-103/4" 36'-1" 2 A-4.2 37 37 37 37 17 17 17 17 3 3 1 3 1 3 3 1 3 3 20 20 20 20 20 20 20 13 G H 9 10 11 12 515.17 510.00 LIVING A-3.7.A1 A-3.7.B2 PWDR. ENTRY DINING KITCHEN DECK LIVING ENTRY DINING KITCHEN DECKPWDR.515.17 KITCHEN LIVING ENTRY KITCHEN DECK DINING 515.17515.17510.00PWDR. PWDR. DINING 515.17 ENTRY LIVING 522.50 522.50 M ATCH LIN E 2 A-4.1 3 A-4.1 UNIT 16 UNIT 15 UNIT 14 UNIT 17 1' - 6" 15' - 10" 10' - 2" 10' - 2" 15' - 10" 1' - 6" 16' - 8 3/4" 10' - 2" 7 1/4" 3' - 7 5/8" 7' - 1" 4' - 2 7/8" 12' - 6 1/2" EQ EQ 2' - 0" 5' - 1 1/2" 3' - 0 1/2" 3' - 0 1/2" 5' - 1 1/2" 2' - 0" EQ EQ 7' - 6 1/2" 9' - 2 1/4" 2' - 7 1/4" 5' - 1" 2' - 5 3/4" EQ EQ 6' - 0" 6' - 6 1/2" 36'-1 " 4'-21/2"12'-37/8"19'-65 /8"1'-3" 6'-67/8"8'-63/4"4'-5" 1'-6" 11"4'-3" 3'-11" 1'-3" 27' - 6" 27' - 6" 27' - 6" 27' - 6" 1' - 6" 18' - 6" 7' - 2 3/4" 3 1/4" 3 1/4" 7' - 2 3/4" 18' - 6" 1' - 6" 20' - 0" 7' - 2 3/4" 3 1/4" 5' - 3 1/2" 3' - 8" 9' - 6 1/2" EQ EQ EQ EQ 9' - 6 1/2" 3' - 8" 5' - 3 1/2" 7' - 1 1/2" 3' - 8" 9' - 2 1/2" EQ EQ 5' - 2 1/2" 11' - 9 1/2" 3' - 8" 3' - 8" 3' - 2" 6'-3"1'-3" 5'-8"7"2'-0" 2 A-4.2 3 3 3 3 4 4 4 4 2 2 2 8 8 8 10 10 10 2 12 4 4 4 4 4 4 20 20 21 3 3 3 224 4 4 4 12 See Unit 16 55 AB CDF E KEY PLAN Colorado Blvd. SantaAnitaBlvd. FLOOR PLAN KEYNOTESKitchen Sink. See Plumbing Drawings. Accessible Kitchen Sink with removable basecabinet below, meeting all requirements of Section1133A.3. Flooring shall continue underneath.Faucet controls meeting all requirements of Section1133A.3. See Plumbing Drawings. Range & Vent Hood O.F.C.I.See Mechanical Drawings . Refrigerator O.F.C.I. 36"W, Standard DepthDishwasher O.F.C.I. 1 1A234 Base Cabinet and Solid-surface Cabinet Top with TileSplash. Owner to select. See Casework Notes . 5 Upper Cabinets. See Casework Notes . 6 Lavatory. See Plumbing Drawings. 7 Accessible Lavatory with removable base cabinetbelow, meeting all requirements of Section 1134A.8.Flooring shall continue underneath. Faucet controlsmeeting all requirements of Section 1133A.3. SeePlumbing Drawings. 7A 30"x48" Clear Floor Space for accessibleappliances & fixtures. See Sheet G-1.2 . Floor-mounted Water Closet.See Plumbing Drawings. 8 Accessible Floor-mounted Water Closet meeting allrequirements of Section 1134A.7. 15" min. seatheight. 44" max. Water Closet controls above floor.5 lb. max. force to operate See Sheet G-1.2 . See Plumbing Drawings. 8A Shower with tile walls to ceiling and tile floor. Slopeshower floor to drain. See Plumbing Drawings. 9 Accessible Shower meeting all requirements ofSection 1134A.5&6. Tile walls to ceiling and tilefloor. Slope shower floor to drain. See Sheet G-1.2 . See Plumbing Drawings. 9A Bathtub. See Plumbing Drawings. 11 Jacuzzi Bathtub. See Plumbing Drawings. 12 Wall-mounted Mirror. 13 Frameless tempered glass Shower Enclosure/doors. 10 Recessed Medicine Cabinet. Cabinet Door withmirror, prefinished painted metal interior withadjustable shelves. 14 Side-by-Side Washer & Dryer, O.F.C.I. 15 Stacked Washer & Dryer, O.F.C.I. 16 GS Smitty Pan with drain under Washer & Dryer. 17 Automatic Washing Machine Water Shutoff Valvewith leak sensor: Intelliflow, Series A2C-M1. 18 Dryer Exhaust Vent Duct, min. 4" diameter, to theoutside, equipped with back-draft damper 19 Interior Stair. See Sheet A-9.6 for stair and handrail details. 21 Provide min. one layer of 5/8" gypsum board atusable underside of stairs. CBC 1009.5.3. 22 Closet rod and 16" shelf above. 23 Full-height linen cabinet. 24 Water heater on 18" high platform above floor. SeeMEP Drawings. Provide 2" galvanized steelrestarining straps to wall. 20 Balcony with approved weatherproof walkingsurface/deck coating system: Dex-O-Tex, or approvedequal, over plywood framing (see Structural Drawings ). Slope min. 1/4" per ft. along flow line. See Sheet A-9.4 for details. 25 Min. 42" high Guardrail. For Details, see: 26 Deck drain. Slope to drain. 27 Outline of Building above. 28 Outline of Roof or Balcony above. 29 Edge of soffit above. See Reflected Ceiling Plans. 30 Clerestory above. For Plans, see: 31 Internal Roof Drain/Overflow Drain. See Plumbing Drawings . Provide installation submittal under Section 075423 (Roofing) for Architect's review.Overflow Drains shall discharge above grade. 34 Type AA-9.41 Type B Type C A-9.44 A-9.47 Type A Type B Type C A-2.61 A-2.63 A-2.65 Clerestory Window above. See Sheet A-2.6 for Plans. 32 2"x4" Prefinished Metal Downspout to dischargeabove grade, typ. 35 Decorative Metal Screen. 36 Air Handling Unit. See Mechanical Drawings . 37 Skylight above. 33 Door Bell. 48" max. AFF andconnected to permanent wiring. 39 Floor Transition & Railing. See Detail 38 A-9.22 Space for Vertical Ductwork. 40 [Note intentionally left blank] 41 [Note intentionally left blank] 42 [Note intentionally left blank] 43 [Note intentionally left blank] 44 [Note intentionally left blank] 45 [Note intentionally left blank] 46 [Note intentionally left blank] 47 LEGENDSoffited Ceiling. See Reflected Ceiling Plansfor heights and details. Javier GonzalezNo. Cxxxxx Exp. x-xx-17 Robert G. TylerNo. C18812 Exp. 8-31-17 Date Reviewed Drawn ByDescription Do not scale drawings. Contractor shall verifyand be responsible for all dimensions andconditions on the site and Tyler Gonzalez Architects, Inc. shall be notified immediately ofany variations from the dimensions and conditions indicated on these drawings. Drawings, specifications, and other documents,including those in electronic form, prepared by the Architect and the Architect's consultants areInstruments of Service for use solely with respect to this Project. The Architect and theArchitect's consultants shall be deemed theauthors and owners of their respective Instruments of Service and shall retain all common law, statutory and other reserved rights, including copyrights. Visual contact withthese documents constitute prima faciaacceptance of these conditions.Architect of RecordIssue Dates Use of Architect's Drawings2015 Tyler Gonzalez Architects, Inc. c Sheet No.Project No.Scale 139 South Hudson Ave., Suite 300Pasadena, CA 91101626.396.9599 www.TGArchitects.netAs indicated A-2.5.A Checker Author 2015-09-3015-13 FLOOR PLANS - BUILDING F501 N. Santa Anita Ave. Arcadia, CA 91006 SANTA ANITA CONDOMINIUMS 1/4" = 1'-0" 1 Garage Floor Plan - Building F - East 1/4" = 1'-0" 2 First Floor Plan - Building F - East N No.DescriptionDate 1/4" = 1'-0"Floor Plan Key Notes 13 G H 9 10 11 12 526.17 526.17 A-3.7.A1 A-3.7.B2 A-3.7.C 1 BEDRM. 2 CL CL BEDRM. 3 LINEN HALLM. BEDRM. BATH M. BEDRM. M. BATH 526.17 BEDRM. 2 CL CL BEDRM. 3 LINEN HALLM. BEDRM. BATH M. BEDRM. M. BATH 526.17 BEDRM. 2 CL CL BEDRM. 3 LINEN HALLM. BEDRM. BATH M. BEDRM. M. BATH BALC. BALC. BALC. BALC. M. BATH W.I.C. M. BEDRM.BATH HALL BEDRM. 3 CL BEDRM. 2CL M ATCH LIN E 2 A-4.1 3 A-4.1 1' - 6" 15' - 10" 10' - 2" 10' - 2" 15' - 10" 1' - 6" 16' - 4 3/4" 10' - 6" 7 1/4" 14' - 11 1/2" 12' - 6 1/2" EQ EQ EQ EQ 7' - 6 1/2" 8' - 10 1/4" 7' - 2 1/8" 7' - 9 3/8" 6' - 0" 6' - 6 1/2" 36'-1" 16'-63/8 "19'-65/8"1'-3" 4'-21/2"4'-13/4"8'-21/8"6'-67/8"8'-63/4"4'-5" 11 "1'-7" 1'-3" 1'-3" 27' - 6" 27' - 6" 27' - 6" 27' - 6" 1' - 6" 18' - 6" 7' - 2 3/4" 3 1/4" 3 1/4" 7' - 2 3/4" 18' - 6" 1' - 6" 20' - 0" 7' - 2 3/4" 3 1/4" 5' - 3 1/2" 3' - 8" 9' - 6 1/2" EQ EQ EQ EQ 9' - 6 1/2" 3' - 8" 5' - 3 1/2" 7' - 1 1/2" 3' - 8" 9' - 2 1/2" 7' - 2 3/4" 5' - 2 1/2" 11' - 9 1/2" 3' - 8" 3' - 8" 2' - 10" 4" 1'-41/8"1'-3" 1'-41/8" 2'-0" EQ EQ 6' - 9 1/2" 3' - 4 1/2" 3' - 4 1/2" 6' - 9 1/2" UNIT 16 UNIT 15 UNIT 14 UNIT 17 A-2.69 A-2.61 2 A-4.2 33 33 33 33 2 2 2 2 2 2 2 2 5 2 1 2 2 2 2 2 2 2 2 5 2 1 2 2 2 2 2 2 2 2 5 1 1 2 5 2 5 2 1 2 2 2 7A 8 8 16 15 11A 11A 8 14 14 7 7 7A 7A 7A 7A 7 27 24 7 7 7 242413 G H 9 10 11 12 1/2"/1'-0 " 1/2" / 1'-0" 1/2"/1'-0 "1/2"/1'-0" 5/8" / 1'-0" 1/2"/1'-0"1/2"/1'-0"1/2"/1'-0"1/2"/1'-0" 535.91 535.91 2 A-4.1 3 A-4.1 3/8"/1'-0" 3/8" / 1'-0" 535.913/8" / 1'-0" 3/8"/1'-0" 538.50 537.67 538.50 538.50 A-2.61 110' - 0" 1' - 6" 15' - 10" 10' - 2" 10' - 2" 15' - 10" 1' - 6" 15' - 10 1/4" 6 1/2" 10' - 10" 3 1/4" 14' - 7 1/2" 12' - 10 1/2" 36'-1" 3'-9"12'-5"19'-11"1'-3" 1'-3"1'-3" 1'-6" 27' - 6" 27' - 6" 27' - 6" 27' - 6" 1' - 6" 18' - 6" 7' - 6" 7' - 6" 18' - 6" 1' - 6" 20' - 0" 7' - 2 3/4" 3 1/4" 27' - 2" 4" 8' - 0 3/8" 10' - 5 5/8" 10' - 5 5/8" 8' - 0 3/8" 9' - 6 3/8" 10' - 5 5/8" 3' - 11 5/8" 23' - 6 3/8" 1'-3"1'-3" 9'-95/8" 12'-113 /4" Typ . 2'-0" Typ. 2' - 0" Typ . 2'-01/8" Typ . 2'-0" 4'-6" Typ . 1'-117/8" 3/8"/1'-0" 3/8" / 1'-0" 538.50 3/8"/1'-0" 3/8" / 1'-0" 3/8" / 1'-0" 3/8"/1'-0 " 2 A-4.2 1 1 1 1 3'-101/2 "16'-01 /2" 2"/1 '-0" 2" / 1'-0" 2"/1'-0 " 2" / 1'-0" 53 50 56 58 51 55 56 50 53 55 51 58 55 51 58 58 52 55 56 55 51 58 56 53 50 58 51 55 56 50 53 51 5450 54 54 AB CDF E KEY PLAN Colorado Blvd. SantaAnitaBlvd. FLOOR PLAN KEYNOTESKitchen Sink. See Plumbing Drawings. Accessible Kitchen Sink with removable basecabinet below, meeting all requirements of Section1133A.3. Flooring shall continue underneath.Faucet controls meeting all requirements of Section1133A.3. See Plumbing Drawings. Range & Vent Hood O.F.C.I.See Mechanical Drawings . Refrigerator O.F.C.I. 36"W, Standard DepthDishwasher O.F.C.I. 1 1A234 Base Cabinet and Solid-surface Cabinet Top with TileSplash. Owner to select. See Casework Notes . 5 Upper Cabinets. See Casework Notes . 6 Lavatory. See Plumbing Drawings. 7 Accessible Lavatory with removable base cabinetbelow, meeting all requirements of Section 1134A.8.Flooring shall continue underneath. Faucet controlsmeeting all requirements of Section 1133A.3. SeePlumbing Drawings. 7A 30"x48" Clear Floor Space for accessibleappliances & fixtures. See Sheet G-1.2 . Floor-mounted Water Closet.See Plumbing Drawings. 8 Accessible Floor-mounted Water Closet meeting allrequirements of Section 1134A.7. 15" min. seatheight. 44" max. Water Closet controls above floor.5 lb. max. force to operate See Sheet G-1.2 . See Plumbing Drawings. 8A Shower with tile walls to ceiling and tile floor. Slopeshower floor to drain. See Plumbing Drawings. 9 Accessible Shower meeting all requirements ofSection 1134A.5&6. Tile walls to ceiling and tilefloor. Slope shower floor to drain. See Sheet G-1.2 . See Plumbing Drawings. 9A Bathtub. See Plumbing Drawings. 11 Jacuzzi Bathtub. See Plumbing Drawings. 12 Wall-mounted Mirror. 13 Frameless tempered glass Shower Enclosure/doors. 10 Recessed Medicine Cabinet. Cabinet Door withmirror, prefinished painted metal interior withadjustable shelves. 14 Side-by-Side Washer & Dryer, O.F.C.I. 15 Stacked Washer & Dryer, O.F.C.I. 16 GS Smitty Pan with drain under Washer & Dryer. 17 Automatic Washing Machine Water Shutoff Valvewith leak sensor: Intelliflow, Series A2C-M1. 18 Dryer Exhaust Vent Duct, min. 4" diameter, to theoutside, equipped with back-draft damper 19 Interior Stair. See Sheet A-9.6 for stair and handrail details. 21 Provide min. one layer of 5/8" gypsum board atusable underside of stairs. CBC 1009.5.3. 22 Closet rod and 16" shelf above. 23 Full-height linen cabinet. 24 Water heater on 18" high platform above floor. SeeMEP Drawings. Provide 2" galvanized steelrestarining straps to wall. 20 Balcony with approved weatherproof walkingsurface/deck coating system: Dex-O-Tex, or approvedequal, over plywood framing (see Structural Drawings ). Slope min. 1/4" per ft. along flow line. See Sheet A-9.4 for details. 25 Min. 42" high Guardrail. For Details, see: 26 Deck drain. Slope to drain. 27 Outline of Building above. 28 Outline of Roof or Balcony above. 29 Edge of soffit above. See Reflected Ceiling Plans. 30 Clerestory above. For Plans, see: 31 Internal Roof Drain/Overflow Drain. See Plumbing Drawings . Provide installation submittal under Section 075423 (Roofing) for Architect's review.Overflow Drains shall discharge above grade. 34 Type AA-9.41 Type B Type C A-9.44 A-9.47 Type A Type B Type C A-2.61 A-2.63 A-2.65 Clerestory Window above. See Sheet A-2.6 for Plans. 32 2"x4" Prefinished Metal Downspout to dischargeabove grade, typ. 35 Decorative Metal Screen. 36 Air Handling Unit. See Mechanical Drawings . 37 Skylight above. 33 Door Bell. 48" max. AFF andconnected to permanent wiring. 39 Floor Transition & Railing. See Detail 38 A-9.22 Space for Vertical Ductwork. 40 [Note intentionally left blank] 41 [Note intentionally left blank] 42 [Note intentionally left blank] 43 [Note intentionally left blank] 44 [Note intentionally left blank] 45 [Note intentionally left blank] 46 [Note intentionally left blank] 47 LEGENDSoffited Ceiling. See Reflected Ceiling Plansfor heights and details. Javier GonzalezNo. Cxxxxx Exp. x-xx-17 Robert G. TylerNo. C18812 Exp. 8-31-17 Date Reviewed Drawn ByDescription Do not scale drawings. Contractor shall verifyand be responsible for all dimensions andconditions on the site and Tyler Gonzalez Architects, Inc. shall be notified immediately ofany variations from the dimensions and conditions indicated on these drawings. Drawings, specifications, and other documents,including those in electronic form, prepared by the Architect and the Architect's consultants areInstruments of Service for use solely with respect to this Project. The Architect and theArchitect's consultants shall be deemed theauthors and owners of their respective Instruments of Service and shall retain all common law, statutory and other reserved rights, including copyrights. Visual contact withthese documents constitute prima faciaacceptance of these conditions.Architect of RecordIssue Dates Use of Architect's Drawings2015 Tyler Gonzalez Architects, Inc. c Sheet No.Project No.Scale 139 South Hudson Ave., Suite 300Pasadena, CA 91101626.396.9599 www.TGArchitects.netAs indicated A-2.5.B Checker Author 2015-09-3015-13 FLOOR PLANS - BUILDING F501 N. Santa Anita Ave. Arcadia, CA 91006 SANTA ANITA CONDOMINIUMS 1/4" = 1'-0" 1 Second Floor Plan - Building F - East 1/4" = 1'-0" 2 Roof Plan - Building F - East N No.DescriptionDate 1/4" = 1'-0"Floor Plan Key Notes 6 7 GH 8 9 505.92 505.92 A-3.7.A2 A-3.7.B1 A-3.7.C 2 GARAGE GARAGE LAUNDRY LAUNDRY CL M A TCHLINE 27' - 6" 27' - 6" 21' - 3 1/2" 6' - 2 1/2" 6' - 2 1/2" 21' - 3 1/2" 10' - 9 3/4" 10' - 5 3/4" 10' - 5 3/4" 10' - 9 3/4" 55' - 0" 1'-0" 3'-6" 15'-103 /4"20'-21 /4" FOR FINISHES & KEYNOTES,SEE UNIT 15 FOR FINISHES & KEYNOTES,SEE UNIT 14 37 37 17 17 20 A-1.3 12 20 CL 6 7 G H 8 9 509.40 510.00 515.17510.00 510.00515.17 A-3.7.A2 A-3.7.B1 A-3.7.C 2 PWDR. ENTRY LIVINGKITCHENDINING ENTRY BEDRM. 1ENTRY LIVING DINING KITCHEN PWDR. DECK 515.17 M A TCHLIN E 1 A-4.1HALL UNIT 20 UNIT 19 UNIT 18 108' - 9 1/2" 53' - 9 1/2" 27' - 6" 27' - 6" 9" 21' - 1" 16' - 6 5/8" 15' - 1 5/8" 3 1/4" 3 1/4" 7' - 2 3/4" 20' - 0" 10' - 1" 11' - 0" 7' - 8 1/8" 8' - 10 1/2" 7' - 9 5/8" 7' - 4" 2' - 6 3/4" 3' - 8" 3' - 8" 12' - 2 3/4" 5' - 4 1/2" EQ EQ 9' - 2 1/2" 3' - 8" 7' - 1 1/2" 36'-1" 2'-3"4'-5"17'-0"6'-3"3'-8"1'-6"1'-0"1'-3" EQ3'-11/2"3'-11/2"EQ 16' - 6" 10' - 8 1/8" 5' - 3" 6' - 6" 14' - 7 1/8" 3 1/4" 7 1/4" 12' - 0" 4' - 6" 7' - 1" 3' - 3 3/4" 3 1/4" 10' - 2" 17' - 0 3/4" 9' - 0 3/4" 8' - 0" 2' - 9 3/4" 5' - 1" 2' - 3 1/4" EQ EQ EQ EQ 7' - 3 1/8" 7' - 4" EQ EQ EQ EQ EQ EQ 7' - 0" 3' - 0" 6' - 6" 6'-3"1'-3" 1'-3"3'-11" 1'-6" 3'-9" 2'-3"9" 1'-6" FOR FINISHES & KEYNOTES,SEE UNIT 15 FOR FINISHES & KEYNOTES,SEE UNIT 14 3 3 3 4 4 4 22 2 3 3 2 2 17 2 8 12 10 2 2 4 4 21 3 22 3 12 8 3 2 2 22 9 11 4 4 4 4 6 20 A-1.3 12 AB CDF E KEY PLAN Colorado Blvd. SantaAnitaBlvd. FLOOR PLAN KEYNOTESKitchen Sink. See Plumbing Drawings. Accessible Kitchen Sink with removable basecabinet below, meeting all requirements of Section1133A.3. Flooring shall continue underneath.Faucet controls meeting all requirements of Section1133A.3. See Plumbing Drawings. Range & Vent Hood O.F.C.I.See Mechanical Drawings . Refrigerator O.F.C.I. 36"W, Standard DepthDishwasher O.F.C.I. 1 1A234 Base Cabinet and Solid-surface Cabinet Top with TileSplash. Owner to select. See Casework Notes . 5 Upper Cabinets. See Casework Notes . 6 Lavatory. See Plumbing Drawings. 7 Accessible Lavatory with removable base cabinetbelow, meeting all requirements of Section 1134A.8.Flooring shall continue underneath. Faucet controlsmeeting all requirements of Section 1133A.3. SeePlumbing Drawings. 7A 30"x48" Clear Floor Space for accessibleappliances & fixtures. See Sheet G-1.2 . Floor-mounted Water Closet.See Plumbing Drawings. 8 Accessible Floor-mounted Water Closet meeting allrequirements of Section 1134A.7. 15" min. seatheight. 44" max. Water Closet controls above floor.5 lb. max. force to operate See Sheet G-1.2 . See Plumbing Drawings. 8A Shower with tile walls to ceiling and tile floor. Slopeshower floor to drain. See Plumbing Drawings. 9 Accessible Shower meeting all requirements ofSection 1134A.5&6. Tile walls to ceiling and tilefloor. Slope shower floor to drain. See Sheet G-1.2 . See Plumbing Drawings. 9A Bathtub. See Plumbing Drawings. 11 Jacuzzi Bathtub. See Plumbing Drawings. 12 Wall-mounted Mirror. 13 Frameless tempered glass Shower Enclosure/doors. 10 Recessed Medicine Cabinet. Cabinet Door withmirror, prefinished painted metal interior withadjustable shelves. 14 Side-by-Side Washer & Dryer, O.F.C.I. 15 Stacked Washer & Dryer, O.F.C.I. 16 GS Smitty Pan with drain under Washer & Dryer. 17 Automatic Washing Machine Water Shutoff Valvewith leak sensor: Intelliflow, Series A2C-M1. 18 Dryer Exhaust Vent Duct, min. 4" diameter, to theoutside, equipped with back-draft damper 19 Interior Stair. See Sheet A-9.6 for stair and handrail details. 21 Provide min. one layer of 5/8" gypsum board atusable underside of stairs. CBC 1009.5.3. 22 Closet rod and 16" shelf above. 23 Full-height linen cabinet. 24 Water heater on 18" high platform above floor. SeeMEP Drawings. Provide 2" galvanized steelrestarining straps to wall. 20 Balcony with approved weatherproof walkingsurface/deck coating system: Dex-O-Tex, or approvedequal, over plywood framing (see Structural Drawings ). Slope min. 1/4" per ft. along flow line. See Sheet A-9.4 for details. 25 Min. 42" high Guardrail. For Details, see: 26 Deck drain. Slope to drain. 27 Outline of Building above. 28 Outline of Roof or Balcony above. 29 Edge of soffit above. See Reflected Ceiling Plans. 30 Clerestory above. For Plans, see: 31 Internal Roof Drain/Overflow Drain. See Plumbing Drawings . Provide installation submittal under Section 075423 (Roofing) for Architect's review.Overflow Drains shall discharge above grade. 34 Type AA-9.41 Type B Type C A-9.44 A-9.47 Type A Type B Type C A-2.61 A-2.63 A-2.65 Clerestory Window above. See Sheet A-2.6 for Plans. 32 2"x4" Prefinished Metal Downspout to dischargeabove grade, typ. 35 Decorative Metal Screen. 36 Air Handling Unit. See Mechanical Drawings . 37 Skylight above. 33 Door Bell. 48" max. AFF andconnected to permanent wiring. 39 Floor Transition & Railing. See Detail 38 A-9.22 Space for Vertical Ductwork. 40 [Note intentionally left blank] 41 [Note intentionally left blank] 42 [Note intentionally left blank] 43 [Note intentionally left blank] 44 [Note intentionally left blank] 45 [Note intentionally left blank] 46 [Note intentionally left blank] 47 LEGENDSoffited Ceiling. See Reflected Ceiling Plansfor heights and details. Javier GonzalezNo. Cxxxxx Exp. x-xx-17 Robert G. TylerNo. C18812 Exp. 8-31-17 Date Reviewed Drawn ByDescription Do not scale drawings. Contractor shall verifyand be responsible for all dimensions andconditions on the site and Tyler Gonzalez Architects, Inc. shall be notified immediately ofany variations from the dimensions and conditions indicated on these drawings. Drawings, specifications, and other documents,including those in electronic form, prepared by the Architect and the Architect's consultants areInstruments of Service for use solely with respect to this Project. The Architect and theArchitect's consultants shall be deemed theauthors and owners of their respective Instruments of Service and shall retain all common law, statutory and other reserved rights, including copyrights. Visual contact withthese documents constitute prima faciaacceptance of these conditions.Architect of RecordIssue Dates Use of Architect's Drawings2015 Tyler Gonzalez Architects, Inc. c Sheet No.Project No.Scale 139 South Hudson Ave., Suite 300Pasadena, CA 91101626.396.9599 www.TGArchitects.netAs indicated A-2.5.C Checker Author 2015-09-3015-13 FLOOR PLANS - BUILDING F501 N. Santa Anita Ave. Arcadia, CA 91006 SANTA ANITA CONDOMINIUMS 1/4" = 1'-0" 1 Garage Floor Plan - Building F - West 1/4" = 1'-0" 2 First Floor Plan - Building F - West N No.DescriptionDate 1/4" = 1'-0"Floor Plan Key Notes 6 7 G H 8 9 2" / 1'-0" 2" / 1'-0" 1/2"/1'-0" 1/2"/1'-0" 1/2" / 1'-0" 1/2"/1'-0"1/2"/1'-0" 1 1/2" / 1'-0" 1/2" / 1'-0" 1/2"/1 '-0" 1/2" / 1'-0" 3/4" / 1'-0" 1/2"/1'-0" 1/2"/1'-0 " M A TCHLIN E 535.91 1 A-4.1 3/8"/1'-0" 1/2"/1 '-0" 3/8"/1 '-0" 3/8" / 1'-0" 3/8" / 1'-0" 3/8"/1'-0" 3/8" / 1'-0" 537.50 537.50 538.50 533.00 533.00 531.82 MA TCHL INE 1/2"/1'-0"1/2"/1 '-0" 108' - 9 1/2" 53' - 9 1/2" 27' - 6" 27' - 6" 9" 21' - 1" 17' - 0 1/4" 14' - 8" 3 1/4" 9' - 2 1/2" 1' - 3 1/8" 9' - 6 3/8" 36'-1" 7'-0"16'-4"6'-7"3'-8"2'-6"1'-3" 4" 16' - 4" 5' - 2" 16' - 2 5/8" 9 5/8" 14' - 8" 3 1/4" 12' - 11 1/4" 12' - 3 1/2" 2' - 2 1/2"3/4" 3 1/4" 10' - 2" 6 1/2" 16' - 6 1/4" 4'-6" 10"2'-11 " 2'-6"9'-03/4"12'-61/4"10'-91/2"51/2 "9"1'-3" A-2.65 3 1/4" 7' - 2 3/4" 20' - 0" 23' - 7" 3' - 11" 12'-113/4" 16'-11/8" 3/8" / 1'-0" 3/8" / 1'-0" 1 1 2"/1'-0" 58 51 55 54 50 54 58 51 55515356 55 52 58 3/8"/1'-0" 55 51 58 55 56 53 51 50 55 51 58 515450 555153 585255 56 6 7 GH 8 9 526.17 526.17 521.00 A-3.7.A2 A-3.7.B1 A-3.7.C 2 M. BATHM. BEDRM. BEDRM. 2 W.I.C. BEDRM. 3BATHBEDRM. 4 STUDYDECK. BALC. BALC. BALC. M. BEDRM.BEDRM. 2 BEDRM. 3 CL CL LINENW.I.C. M. BATH BATH HALL BEDRM. 3 CL BEDRM. 2 CL HALL LINENW.I.C. BATH M. BEDRM. M. BATH BALC. M A TCHLINE BALC. 1 A-4.1 108' - 9 1/2" 53' - 9 1/2" 27' - 6" 27' - 6" 9" 21' - 1" 17' - 0 1/4" 14' - 8" 3 1/4" 3 1/4" 7' - 2 3/4" 20' - 0" 2' - 1" 8' - 0" 8' - 0" 3' - 0" 7' - 8 1/8" 9' - 4 1/8" 7' - 4" 7' - 4" 2' - 6 3/4" 3' - 8" 3' - 8" 12' - 2 3/4" 5' - 4 1/2" EQ EQ 9' - 2 1/2" 3' - 8" 7' - 1 1/2" 36'-1" 6'-8"17'-0"6'-3"3'-8"2'-6"1'-3" EQEQ 17' - 0" 4' - 10" 16' - 2 5/8" 15' - 5 5/8" 3 1/4" 7 1/4" 12' - 0" 14' - 10 3/4" 3 1/4" 10' - 2" 17' - 0 3/4" 1'-3" 1'-3" 3'-9" 3'-4"4'-6" 5' - 7" 4' - 7" 9' - 0 3/4" 8' - 0" 8' - 0 1/2" 6' - 10 1/4" EQ EQ 2' - 5 5/8" 3' - 8" 3' - 8" 3' - 8" 2' - 9" 8' - 1 5/8" 7' - 4" EQ EQ EQ EQ 1'-41/8" 1'-3" UNIT 20 UNIT 19 UNIT 18 A-2.65 37 33 33 7 5 2 1 2 22 2 5 2 2 2 2 2 2 1 2 2 2 2 2 5 2 2 2 2 5 2 5 2 2 1 2 2 2 2 15 16 14 7 7 9 7A 7A 7A 7A 13 13 8 7A 11 8 3 3 3 8A 7 7 7 7 EQEQ AB CDF E KEY PLAN Colorado Blvd. SantaAnitaBlvd. FLOOR PLAN KEYNOTESKitchen Sink. See Plumbing Drawings. Accessible Kitchen Sink with removable basecabinet below, meeting all requirements of Section1133A.3. Flooring shall continue underneath.Faucet controls meeting all requirements of Section1133A.3. See Plumbing Drawings. Range & Vent Hood O.F.C.I.See Mechanical Drawings . Refrigerator O.F.C.I. 36"W, Standard DepthDishwasher O.F.C.I. 1 1A234 Base Cabinet and Solid-surface Cabinet Top with TileSplash. Owner to select. See Casework Notes . 5 Upper Cabinets. See Casework Notes . 6 Lavatory. See Plumbing Drawings. 7 Accessible Lavatory with removable base cabinetbelow, meeting all requirements of Section 1134A.8.Flooring shall continue underneath. Faucet controlsmeeting all requirements of Section 1133A.3. SeePlumbing Drawings. 7A 30"x48" Clear Floor Space for accessibleappliances & fixtures. See Sheet G-1.2 . Floor-mounted Water Closet.See Plumbing Drawings. 8 Accessible Floor-mounted Water Closet meeting allrequirements of Section 1134A.7. 15" min. seatheight. 44" max. Water Closet controls above floor.5 lb. max. force to operate See Sheet G-1.2 . See Plumbing Drawings. 8A Shower with tile walls to ceiling and tile floor. Slopeshower floor to drain. See Plumbing Drawings. 9 Accessible Shower meeting all requirements ofSection 1134A.5&6. Tile walls to ceiling and tilefloor. Slope shower floor to drain. See Sheet G-1.2 . See Plumbing Drawings. 9A Bathtub. See Plumbing Drawings. 11 Jacuzzi Bathtub. See Plumbing Drawings. 12 Wall-mounted Mirror. 13 Frameless tempered glass Shower Enclosure/doors. 10 Recessed Medicine Cabinet. Cabinet Door withmirror, prefinished painted metal interior withadjustable shelves. 14 Side-by-Side Washer & Dryer, O.F.C.I. 15 Stacked Washer & Dryer, O.F.C.I. 16 GS Smitty Pan with drain under Washer & Dryer. 17 Automatic Washing Machine Water Shutoff Valvewith leak sensor: Intelliflow, Series A2C-M1. 18 Dryer Exhaust Vent Duct, min. 4" diameter, to theoutside, equipped with back-draft damper 19 Interior Stair. See Sheet A-9.6 for stair and handrail details. 21 Provide min. one layer of 5/8" gypsum board atusable underside of stairs. CBC 1009.5.3. 22 Closet rod and 16" shelf above. 23 Full-height linen cabinet. 24 Water heater on 18" high platform above floor. SeeMEP Drawings. Provide 2" galvanized steelrestarining straps to wall. 20 Balcony with approved weatherproof walkingsurface/deck coating system: Dex-O-Tex, or approvedequal, over plywood framing (see Structural Drawings ). Slope min. 1/4" per ft. along flow line. See Sheet A-9.4 for details. 25 Min. 42" high Guardrail. For Details, see: 26 Deck drain. Slope to drain. 27 Outline of Building above. 28 Outline of Roof or Balcony above. 29 Edge of soffit above. See Reflected Ceiling Plans. 30 Clerestory above. For Plans, see: 31 Internal Roof Drain/Overflow Drain. See Plumbing Drawings . Provide installation submittal under Section 075423 (Roofing) for Architect's review.Overflow Drains shall discharge above grade. 34 Type AA-9.41 Type B Type C A-9.44 A-9.47 Type A Type B Type C A-2.61 A-2.63 A-2.65 Clerestory Window above. See Sheet A-2.6 for Plans. 32 2"x4" Prefinished Metal Downspout to dischargeabove grade, typ. 35 Decorative Metal Screen. 36 Air Handling Unit. See Mechanical Drawings . 37 Skylight above. 33 Door Bell. 48" max. AFF andconnected to permanent wiring. 39 Floor Transition & Railing. See Detail 38 A-9.22 Space for Vertical Ductwork. 40 [Note intentionally left blank] 41 [Note intentionally left blank] 42 [Note intentionally left blank] 43 [Note intentionally left blank] 44 [Note intentionally left blank] 45 [Note intentionally left blank] 46 [Note intentionally left blank] 47 LEGENDSoffited Ceiling. See Reflected Ceiling Plansfor heights and details. Javier GonzalezNo. Cxxxxx Exp. x-xx-17 Robert G. TylerNo. C18812 Exp. 8-31-17 Date Reviewed Drawn ByDescription Do not scale drawings. Contractor shall verifyand be responsible for all dimensions andconditions on the site and Tyler Gonzalez Architects, Inc. shall be notified immediately ofany variations from the dimensions and conditions indicated on these drawings. Drawings, specifications, and other documents,including those in electronic form, prepared by the Architect and the Architect's consultants areInstruments of Service for use solely with respect to this Project. The Architect and theArchitect's consultants shall be deemed theauthors and owners of their respective Instruments of Service and shall retain all common law, statutory and other reserved rights, including copyrights. Visual contact withthese documents constitute prima faciaacceptance of these conditions.Architect of RecordIssue Dates Use of Architect's Drawings2015 Tyler Gonzalez Architects, Inc. c Sheet No.Project No.Scale 139 South Hudson Ave., Suite 300Pasadena, CA 91101626.396.9599 www.TGArchitects.netAs indicated A-2.5.D Checker Author 2015-09-3015-13 FLOOR PLANS - BUILDING F501 N. Santa Anita Ave. Arcadia, CA 91006 SANTA ANITA CONDOMINIUMS 1/4" = 1'-0" 2 Roof Plan - Building F - West 1/4" = 1'-0" 1 Second Floor Plan - Building F - West N No.DescriptionDate 1/4" = 1'-0"Floor Plan Key Notes First Floor South510' - 0"Second Floor AB521' - 0" Second Floor CDEF526' - 2" Attic AB 531' - 0"T.O. Roof AB536' - 0" 5 1 6 7 13 22 23 Mezzanine Floor515' - 2"Attic CDEF535' - 6"T.O. Roof CDEF539' - 6" 5'-0"10'-0"11'-0" 4 A-3.1 26'-0" 4'-0"9'-4"11'-0"4'-7" 28 '-11 " 30'-0" HEIGHT LIMIT First Floor East510' - 7" Second Floor AB521' - 0" Second Floor CDEF526' - 2" Attic AB 531' - 0"T.O. Roof AB536' - 0" 22 21 18 17 14 23 Mezzanine Floor515' - 2"Attic CDEF535' - 6"T.O. Roof CDEF539' - 6" 4 A-3.1 15 9'-10"10'-0"5'-0" 4'-7"11'-0"9'-4"4'-0" 30'-0" HEIGHT LIMIT First Floor East510' - 7" First Floor North511' - 2" 24'-10" 28'-11" First Floor South510' - 0"Second Floor AB521' - 0" Garage Level505' - 11" Garage Level505' - 11" Garage AB 509' - 4 3/4" Second Floor CDEF526' - 2" Attic AB 531' - 0"T.O. Roof AB536' - 0" 22 21 18 17 14 23 Mezzanine Floor515' - 2"Attic CDEF535' - 6"T.O. Roof CDEF539' - 6" 4 A-3.1 5'-0"10'-0"11'-0" 26'-0"71/4" 4'-0"9'-4"11'-0"4'-7" 28'-11" 30'-0" HEIGHT LIMIT First Floor East510' - 7" First Floor North511' - 2" 28'-11"4'-8" First Floor South510' - 0"Second Floor AB521' - 0" Garage Level505' - 11" Garage AB 509' - 4 3/4" Second Floor CDEF526' - 2" Attic AB 531' - 0"T.O. Roof AB536' - 0" 4 5 3 1 6 7 13 22 23 Mezzanine Floor515' - 2"Attic CDEF535' - 6"T.O. Roof CDEF539' - 6" 4 A-3.1 71 /4 "11 '-0"10 '-0"5'-0" 26 '-0 " 4'-7"11'-0"9'-4"4'-0" 4'-8"28'-11" 30'-0" HEIGHT LIMIT First Floor East510' - 7" Javier GonzalezNo. Cxxxxx Exp. x-xx-17 Robert G. TylerNo. C18812 Exp. 8-31-17 Date Reviewed Drawn ByDescription Do not scale drawings. Contractor shall verifyand be responsible for all dimensions andconditions on the site and Tyler Gonzalez Architects, Inc. shall be notified immediately ofany variations from the dimensions and conditions indicated on these drawings. Drawings, specifications, and other documents,including those in electronic form, prepared by the Architect and the Architect's consultants areInstruments of Service for use solely with respect to this Project. The Architect and theArchitect's consultants shall be deemed theauthors and owners of their respective Instruments of Service and shall retain all common law, statutory and other reserved rights, including copyrights. Visual contact withthese documents constitute prima faciaacceptance of these conditions.Architect of RecordIssue Dates Use of Architect's Drawings2015 Tyler Gonzalez Architects, Inc. c Sheet No.Project No.Scale 139 South Hudson Ave., Suite 300Pasadena, CA 91101626.396.9599 www.TGArchitects.net 1/16" = 1'-0" A-3.0 Checker Author 2015-09-3015-13STREET ELEVATIONS501 N. Santa Anita Ave. Arcadia, CA 91006 SANTA ANITA CONDOMINIUMS 1/16" = 1'-0" 1 South Elevation - Colorado Boulevard 1/16" = 1'-0" 2 North Elevation 1/16" = 1'-0" 3 South Elevation - Alley 1/16" = 1'-0" 4 North Elevation - Alley & Cornell Drive No.DescriptionDate First Floor South510' - 0" Garage Level505' - 11" Garage Level505' - 11" Second Floor CDEF526' - 2" Second Floor CDEF526' - 2" G F H Mezzanine Floor515' - 2" Mezzanine Floor515' - 2" Attic CDEF535' - 6" Attic CDEF535' - 6" T.O. Roof CDEF539' - 6" T.O. Roof CDEF539' - 6" PRO PERTYLINE PRO PERTYLINE 4'-0"9'-4"11'-0"5'-2" 29'-6"4'-1" A A-1.38 30'-0" HEIGHT LIMIT First Floor North511' - 2" 4'-0"9'-4"11'-0"5'-2" 29'-6"4'-1" 4'-0"9'-4"11'-0"5'-2" 4'-0"9'-4"11'-0"4'-0" 28'-4"5'-3" Garage Level505' - 11"Second Floor CDEF526' - 2" E Mezzanine Floor515' - 2"Attic CDEF535' - 6"T.O. Roof CDEF539' - 6" 4'-0"9'-4"11'-0"4'-7" 28'-11"4'-8" A 30'-0" HEIGHT LIMIT First Floor East510' - 7" Second Floor CDEF526' - 2" E Mezzanine Floor515' - 2"Attic CDEF535' - 6"T.O. Roof CDEF539' - 6" 4'-0"9'-4"11'-0 "4'-7" PRO PERTYLINE PRO PERTYL INE A 30'-0" HEIGHT LIMIT First Floor East510' - 7" 28'-11 " First Floor South510' - 0"Garage Level505' - 11" Garage Level505' - 11" Second Floor CDEF526' - 2" Second Floor CDEF526' - 2" G F H Mezzanine Floor515' - 2" Mezzanine Floor515' - 2" Attic CDEF535' - 6" Attic CDEF535' - 6" T.O. Roof CDEF539' - 6" T.O. Roof CDEF539' - 6" 4'-0"9'-4"11'-0"4'-0" 28'-4"5'-3" A 30'-0" HEIGHT LIMIT First Floor North511' - 2" 4'-0"9'-4"11'-0"5'-2" 29'-6 "4'-1" First Floor South510' - 0"Second Floor AB521' - 0"Garage AB 509' - 4 3/4"Attic AB 531' - 0"T.O. Roof AB536' - 0" G F H 5'-0"10'-0"11'-0"71/4" 26'-0" A 30'-0" HEIGHT LIMIT First Floor South510' - 0"Second Floor AB521' - 0"Garage AB 509' - 4 3/4"Attic AB 531' - 0"T.O. Roof AB536' - 0" K L 5'-0"10'-0"11'-0" 26'-0"71/4" 12'-4" A-1.39 30'-0" HEIGHT LIMIT M Javier GonzalezNo. Cxxxxx Exp. x-xx-17 Robert G. TylerNo. C18812 Exp. 8-31-17 Date Reviewed Drawn ByDescription Do not scale drawings. Contractor shall verifyand be responsible for all dimensions andconditions on the site and Tyler Gonzalez Architects, Inc. shall be notified immediately ofany variations from the dimensions and conditions indicated on these drawings. Drawings, specifications, and other documents,including those in electronic form, prepared by the Architect and the Architect's consultants areInstruments of Service for use solely with respect to this Project. The Architect and theArchitect's consultants shall be deemed theauthors and owners of their respective Instruments of Service and shall retain all common law, statutory and other reserved rights, including copyrights. Visual contact withthese documents constitute prima faciaacceptance of these conditions.Architect of RecordIssue Dates Use of Architect's Drawings2015 Tyler Gonzalez Architects, Inc. c Sheet No.Project No.Scale 139 South Hudson Ave., Suite 300Pasadena, CA 91101626.396.9599 www.TGArchitects.net 1/16" = 1'-0" A-3.1 Checker Author 2015-09-3015-13STREET ELEVATIONS501 N. Santa Anita Ave. Arcadia, CA 91006 SANTA ANITA CONDOMINIUMS 1/16" = 1'-0" 4 North-South Section 2 1/16" = 1'-0" 5 East Elevation - Alley 1/16" = 1'-0" 1 East Elevation - Santa Anita Avenue 1/16" = 1'-0" 2 West Elevation - Alley 1/16" = 1'-0" 3 West Elevation - Windsor Road 1/16" = 1'-0" 6 North-South Section 1 No.DescriptionDate First Floor South510' - 0"Second Floor AB521' - 0"Garage AB 509' - 4 3/4"Attic AB 531' - 0"T.O. Roof AB536' - 0" 3 1 2 1 A-4.0 11'-0 "10'-0"5'-0" 71/4 "26'-0" 8 8 17 12 7A 11A 7 1212 15 19 15 10 8 11 1 6 5 3 13 2 11 9 7 18 First Floor South510' - 0"Second Floor AB521' - 0"Garage AB 509' - 4 3/4"Attic AB 531' - 0"T.O. Roof AB536' - 0" 3 1 2 5'-0"10'-0"11'-0" 26'-0"71/4" 1 A-4.0 3 32 2 2 2 6 9A 11 5 19 156 15 10 1 3 5 6 2 8 13 3 18 18 18 ELEVATION KEYNOTESLa Habra Exterior PlasterFinish: 20/30 Float (Sand) Color: X-40 Dove Gray (Integrated)La Habra Exterior PlasterFinish: 20/30 Float (Sand) Color : X-81583 Belle Glade (Integrated)Coronado Precast Stone Veneer Finish : Chiseled Limestone Color: Silver Ash Firestone CCRRC-Applied Cool RoofFeat.: Thermoplastic Polyolefin (TPO) Color: White Painted Metal FasciaU.S. Aluminum Windows & Doors Model : Standard Aluminum Finish : Bronze Anodized Feat. : Thermally Improved Overhead Doors Garage DoorModel: Standard Aluminum Color : Dark Bronze AnodizedAluminum OverhangColor: Dark Bronze AnodizedAluminum RailingColor: Dark Bronze AnodizedAluminum FenceColor: Dark Bronze AnodizedAluminum Spandrel PanelColor: Dark Bronze AnodizedAluminum DividerColor: Dark Bronze AnodizedMetal PostColor: Dark Bronze AnodizedMetal ScreenColor: Dark Bronze Anodized Roof Eave w/ Integrated Aluminum4"x6" Gutter & DownspoutColor: Dark Anodized Bronze 21346789 10111213141516 Standing Seam Metal Roof 5 Air Conditioning Unit (screened or concealed) 17 Specified Wall Sconce & Unit Number, Typ. 18 Javier GonzalezNo. Cxxxxx Exp. x-xx-17 Robert G. TylerNo. C18812 Exp. 8-31-17 Date Reviewed Drawn ByDescription Do not scale drawings. Contractor shall verifyand be responsible for all dimensions andconditions on the site and Tyler Gonzalez Architects, Inc. shall be notified immediately ofany variations from the dimensions and conditions indicated on these drawings. Drawings, specifications, and other documents,including those in electronic form, prepared by the Architect and the Architect's consultants areInstruments of Service for use solely with respect to this Project. The Architect and theArchitect's consultants shall be deemed theauthors and owners of their respective Instruments of Service and shall retain all common law, statutory and other reserved rights, including copyrights. Visual contact withthese documents constitute prima faciaacceptance of these conditions.Architect of RecordIssue Dates Use of Architect's Drawings2015 Tyler Gonzalez Architects, Inc. c Sheet No.Project No.Scale 139 South Hudson Ave., Suite 300Pasadena, CA 91101626.396.9599 www.TGArchitects.net 1/4" = 1'-0" A-3.2.A Checker Author 2015-09-3015-13 ELEVATIONS - BUILDING A501 N. Santa Anita Ave. Arcadia, CA 91006 SANTA ANITA CONDOMINIUMS 1/4" = 1'-0" 1 North Elev. - Building A 1/4" = 1'-0" 2 South Elev. - Building A No.DescriptionDate First Floor South510' - 0"Second Floor AB521' - 0"Garage AB 509' - 4 3/4"Attic AB 531' - 0"T.O. Roof AB536' - 0" K L 5'-0"10'-0"11'-0 " 26'-0"71 /4" 17 3 3 18 3 2 1 6 6 15 10 11 3 9 First Floor South510' - 0"Second Floor AB521' - 0"Garage AB 509' - 4 3/4"Attic AB 531' - 0"T.O. Roof AB536' - 0" K L 3 6 3 18 8 1 5 6 2 9 2 11 2 2 ELEVATION KEYNOTESLa Habra Exterior PlasterFinish: 20/30 Float (Sand) Color: X-40 Dove Gray (Integrated)La Habra Exterior PlasterFinish: 20/30 Float (Sand) Color : X-81583 Belle Glade (Integrated)Coronado Precast Stone Veneer Finish : Chiseled Limestone Color: Silver Ash Firestone CCRRC-Applied Cool RoofFeat.: Thermoplastic Polyolefin (TPO) Color: White Painted Metal FasciaU.S. Aluminum Windows & Doors Model : Standard Aluminum Finish : Bronze Anodized Feat. : Thermally Improved Overhead Doors Garage DoorModel: Standard Aluminum Color : Dark Bronze AnodizedAluminum OverhangColor: Dark Bronze AnodizedAluminum RailingColor: Dark Bronze AnodizedAluminum FenceColor: Dark Bronze AnodizedAluminum Spandrel PanelColor: Dark Bronze AnodizedAluminum DividerColor: Dark Bronze AnodizedMetal PostColor: Dark Bronze AnodizedMetal ScreenColor: Dark Bronze Anodized Roof Eave w/ Integrated Aluminum4"x6" Gutter & DownspoutColor: Dark Anodized Bronze 21346789 10111213141516 Standing Seam Metal Roof 5 Air Conditioning Unit (screened or concealed) 17 Specified Wall Sconce & Unit Number, Typ. 18 Javier GonzalezNo. Cxxxxx Exp. x-xx-17 Robert G. TylerNo. C18812 Exp. 8-31-17 Date Reviewed Drawn ByDescription Do not scale drawings. Contractor shall verifyand be responsible for all dimensions andconditions on the site and Tyler Gonzalez Architects, Inc. shall be notified immediately ofany variations from the dimensions and conditions indicated on these drawings. Drawings, specifications, and other documents,including those in electronic form, prepared by the Architect and the Architect's consultants areInstruments of Service for use solely with respect to this Project. The Architect and theArchitect's consultants shall be deemed theauthors and owners of their respective Instruments of Service and shall retain all common law, statutory and other reserved rights, including copyrights. Visual contact withthese documents constitute prima faciaacceptance of these conditions.Architect of RecordIssue Dates Use of Architect's Drawings2015 Tyler Gonzalez Architects, Inc. c Sheet No.Project No.Scale 139 South Hudson Ave., Suite 300Pasadena, CA 91101626.396.9599 www.TGArchitects.net 1/4" = 1'-0" A-3.2.B Checker Author 2015-09-3015-13 ELEVATIONS - BUILDING A501 N. Santa Anita Ave. Arcadia, CA 91006 SANTA ANITA CONDOMINIUMS 1/4" = 1'-0" 1 East Elev. - Building A 1/4" = 1'-0" 2 West Elev. - Building A No.DescriptionDate First Floor South510' - 0"Second Floor AB521' - 0"Garage AB 509' - 4 3/4"Attic AB 531' - 0"T.O. Roof AB536' - 0" 4 5 11'-0"10'-0"5'-0" 71/4"26'-0" 2 A-4.0 8 7A 7A 7A 3 12 13 26 23 8 5 3 5 4 2 15 8 3 18 First Floor South510' - 0"Second Floor AB521' - 0"Garage AB 509' - 4 3/4"Attic AB 531' - 0"T.O. Roof AB536' - 0" L J M 1015 23 23 3A 3A 3A 9 8 10 2 5 6 18 11 15 First Floor South510' - 0"Second Floor AB521' - 0"Garage AB 509' - 4 3/4"Attic AB 531' - 0"T.O. Roof AB536' - 0" 4 5 2 A-4.0 8 8 3 2 2 3A 3A 3 3 6 2 3 8 1 5 6 2 10 First Floor South510' - 0"Second Floor AB521' - 0"Garage AB 509' - 4 3/4"Attic AB 531' - 0"T.O. Roof AB536' - 0" L J M 17 3 3 7A7 3 11 10 5 6 8 1 2 3 9 ELEVATION KEYNOTESLa Habra Exterior PlasterFinish: 20/30 Float (Sand) Color: X-40 Dove Gray (Integrated)La Habra Exterior PlasterFinish: 20/30 Float (Sand) Color : X-81583 Belle Glade (Integrated)Coronado Precast Stone Veneer Finish : Chiseled Limestone Color: Silver Ash Firestone CCRRC-Applied Cool RoofFeat.: Thermoplastic Polyolefin (TPO) Color: White Painted Metal FasciaU.S. Aluminum Windows & Doors Model : Standard Aluminum Finish : Bronze Anodized Feat. : Thermally Improved Overhead Doors Garage DoorModel: Standard Aluminum Color : Dark Bronze AnodizedAluminum OverhangColor: Dark Bronze AnodizedAluminum RailingColor: Dark Bronze AnodizedAluminum FenceColor: Dark Bronze AnodizedAluminum Spandrel PanelColor: Dark Bronze AnodizedAluminum DividerColor: Dark Bronze AnodizedMetal PostColor: Dark Bronze AnodizedMetal ScreenColor: Dark Bronze Anodized Roof Eave w/ Integrated Aluminum4"x6" Gutter & DownspoutColor: Dark Anodized Bronze 21346789 10111213141516 Standing Seam Metal Roof 5 Air Conditioning Unit (screened or concealed) 17 Specified Wall Sconce & Unit Number, Typ. 18 Javier GonzalezNo. Cxxxxx Exp. x-xx-17 Robert G. TylerNo. C18812 Exp. 8-31-17 Date Reviewed Drawn ByDescription Do not scale drawings. Contractor shall verifyand be responsible for all dimensions andconditions on the site and Tyler Gonzalez Architects, Inc. shall be notified immediately ofany variations from the dimensions and conditions indicated on these drawings. Drawings, specifications, and other documents,including those in electronic form, prepared by the Architect and the Architect's consultants areInstruments of Service for use solely with respect to this Project. The Architect and theArchitect's consultants shall be deemed theauthors and owners of their respective Instruments of Service and shall retain all common law, statutory and other reserved rights, including copyrights. Visual contact withthese documents constitute prima faciaacceptance of these conditions.Architect of RecordIssue Dates Use of Architect's Drawings2015 Tyler Gonzalez Architects, Inc. c Sheet No.Project No.Scale 139 South Hudson Ave., Suite 300Pasadena, CA 91101626.396.9599 www.TGArchitects.net 1/4" = 1'-0" A-3.3 Checker Author 2015-09-3015-13 ELEVATIONS - BUILDING B501 N. Santa Anita Ave. Arcadia, CA 91006 SANTA ANITA CONDOMINIUMS 1/4" = 1'-0" 1 North Elev. - Building B 1/4" = 1'-0" 2 East Elev. - Building B 1/4" = 1'-0" 3 South Elev. - Building B 1/4" = 1'-0" 4 West Elev. - Building B No.DescriptionDate First Floor South510' - 0"Second Floor AB521' - 0" Garage Level505' - 11" Garage AB 509' - 4 3/4" Second Floor CDEF526' - 2" Attic AB 531' - 0"T.O. Roof AB536' - 0" 17 14 Mezzanine Floor515' - 2"Attic CDEF535' - 6"T.O. Roof CDEF539' - 6" 15 16 4'-0"9'-4"11'-0"4'-0" 28'-4 "5'-3" - --- 4 A-4.0 First Floor North511' - 2" 5 A-4.0 17 17 7A 7A 4 4 7A 7A 4 4 10 10 14 14 6 9A 33 1 6 2 16 3 8 15 8 10 13 11 12 First Floor South510' - 0"Second Floor AB521' - 0"Garage AB 509' - 4 3/4" Second Floor CDEF526' - 2" Attic AB 531' - 0"T.O. Roof AB536' - 0" 17 14 Mezzanine Floor515' - 2"Attic CDEF535' - 6"T.O. Roof CDEF539' - 6" 15 16 11'-0"10'-0 "5'-0" 71/4"26'-0" - --- 4 A-4.0 First Floor North511' - 2" 5 A-4.0 8 3A 8 8 3 3 13 9A 20 20 8 8 16 2 7 1 10 8 8A 8A 3 18 13 15 3 ELEVATION KEYNOTESLa Habra Exterior PlasterFinish: 20/30 Float (Sand) Color: X-40 Dove Gray (Integrated)La Habra Exterior PlasterFinish: 20/30 Float (Sand) Color : X-81583 Belle Glade (Integrated)Coronado Precast Stone Veneer Finish : Chiseled Limestone Color: Silver Ash Firestone CCRRC-Applied Cool RoofFeat.: Thermoplastic Polyolefin (TPO) Color: White Painted Metal FasciaU.S. Aluminum Windows & Doors Model : Standard Aluminum Finish : Bronze Anodized Feat. : Thermally Improved Overhead Doors Garage DoorModel: Standard Aluminum Color : Dark Bronze AnodizedAluminum OverhangColor: Dark Bronze AnodizedAluminum RailingColor: Dark Bronze AnodizedAluminum FenceColor: Dark Bronze AnodizedAluminum Spandrel PanelColor: Dark Bronze AnodizedAluminum DividerColor: Dark Bronze AnodizedMetal PostColor: Dark Bronze AnodizedMetal ScreenColor: Dark Bronze Anodized Roof Eave w/ Integrated Aluminum4"x6" Gutter & DownspoutColor: Dark Anodized Bronze 21346789 10111213141516 Standing Seam Metal Roof 5 Air Conditioning Unit (screened or concealed) 17 Specified Wall Sconce & Unit Number, Typ. 18 Javier GonzalezNo. Cxxxxx Exp. x-xx-17 Robert G. TylerNo. C18812 Exp. 8-31-17 Date Reviewed Drawn ByDescription Do not scale drawings. Contractor shall verifyand be responsible for all dimensions andconditions on the site and Tyler Gonzalez Architects, Inc. shall be notified immediately ofany variations from the dimensions and conditions indicated on these drawings. Drawings, specifications, and other documents,including those in electronic form, prepared by the Architect and the Architect's consultants areInstruments of Service for use solely with respect to this Project. The Architect and theArchitect's consultants shall be deemed theauthors and owners of their respective Instruments of Service and shall retain all common law, statutory and other reserved rights, including copyrights. Visual contact withthese documents constitute prima faciaacceptance of these conditions.Architect of RecordIssue Dates Use of Architect's Drawings2015 Tyler Gonzalez Architects, Inc. c Sheet No.Project No.Scale 139 South Hudson Ave., Suite 300Pasadena, CA 91101626.396.9599 www.TGArchitects.net 1/4" = 1'-0" A-3.4.A Checker Author 2015-09-3015-13 ELEVATIONS - BUILDING C501 N. Santa Anita Ave. Arcadia, CA 91006 SANTA ANITA CONDOMINIUMS 1/4" = 1'-0" 2 South Elev. - Building C 1/4" = 1'-0" 1 North Elev. - Building C No.DescriptionDate Garage Level505' - 11"Second Floor CDEF526' - 2" F Mezzanine Floor515' - 2"Attic CDEF535' - 6"T.O. Roof CDEF539' - 6" 4'-0"9'-4"11'-0"4'-0" 28'-4"5'-3" A 1 A-4.2 First Floor North511' - 2" 25 25 14 25 1 2 7 4 6 8 3 11 First Floor South510' - 0"Second Floor AB521' - 0"Garage AB 509' - 4 3/4"Attic AB 531' - 0"T.O. Roof AB536' - 0" F 5'-0"10'-0"11'-0" 26'-0 "71 /4" A 1 A-4.2 17 3 16 17 1 5 6 2 15 8 9 3 ELEVATION KEYNOTESLa Habra Exterior PlasterFinish: 20/30 Float (Sand) Color: X-40 Dove Gray (Integrated)La Habra Exterior PlasterFinish: 20/30 Float (Sand) Color : X-81583 Belle Glade (Integrated)Coronado Precast Stone Veneer Finish : Chiseled Limestone Color: Silver Ash Firestone CCRRC-Applied Cool RoofFeat.: Thermoplastic Polyolefin (TPO) Color: White Painted Metal FasciaU.S. Aluminum Windows & Doors Model : Standard Aluminum Finish : Bronze Anodized Feat. : Thermally Improved Overhead Doors Garage DoorModel: Standard Aluminum Color : Dark Bronze AnodizedAluminum OverhangColor: Dark Bronze AnodizedAluminum RailingColor: Dark Bronze AnodizedAluminum FenceColor: Dark Bronze AnodizedAluminum Spandrel PanelColor: Dark Bronze AnodizedAluminum DividerColor: Dark Bronze AnodizedMetal PostColor: Dark Bronze AnodizedMetal ScreenColor: Dark Bronze Anodized Roof Eave w/ Integrated Aluminum4"x6" Gutter & DownspoutColor: Dark Anodized Bronze 21346789 10111213141516 Standing Seam Metal Roof 5 Air Conditioning Unit (screened or concealed) 17 Specified Wall Sconce & Unit Number, Typ. 18 Javier GonzalezNo. Cxxxxx Exp. x-xx-17 Robert G. TylerNo. C18812 Exp. 8-31-17 Date Reviewed Drawn ByDescription Do not scale drawings. Contractor shall verifyand be responsible for all dimensions andconditions on the site and Tyler Gonzalez Architects, Inc. shall be notified immediately ofany variations from the dimensions and conditions indicated on these drawings. Drawings, specifications, and other documents,including those in electronic form, prepared by the Architect and the Architect's consultants areInstruments of Service for use solely with respect to this Project. The Architect and theArchitect's consultants shall be deemed theauthors and owners of their respective Instruments of Service and shall retain all common law, statutory and other reserved rights, including copyrights. Visual contact withthese documents constitute prima faciaacceptance of these conditions.Architect of RecordIssue Dates Use of Architect's Drawings2015 Tyler Gonzalez Architects, Inc. c Sheet No.Project No.Scale 139 South Hudson Ave., Suite 300Pasadena, CA 91101626.396.9599 www.TGArchitects.net 1/4" = 1'-0" A-3.4.B Checker Author 2015-09-3015-13 ELEVATIONS - BUILDING C501 N. Santa Anita Ave. Arcadia, CA 91006 SANTA ANITA CONDOMINIUMS 1/4" = 1'-0" 1 East Elev. - Building C 1/4" = 1'-0" 2 West Elev. - Building C No.DescriptionDate Second Floor CDEF526' - 2" 21 18 Mezzanine Floor515' - 2"Attic CDEF535' - 6"T.O. Roof CDEF539' - 6" 19 20 4 A-4.0 2 A-4.1 First Floor North511' - 2" 8 3 8A 20 20 8 8 8 3 3 8 21 10 1 2 5 8 9 8A 8A 2 3 8 18 1310 Garage Level505' - 11"Second Floor CDEF526' - 2" 21 18 Mezzanine Floor515' - 2"Attic CDEF535' - 6"T.O. Roof CDEF539' - 6" 19 20 4'-0"9'-4"11'-0 "4'-0" 28'-4"5'-3" 4 A-4.0 2 A-4.1 First Floor North511' - 2" 10 4 5 1 10 8A 7 7 7A 7A4 4 4 4 10 14 14 10 10 7A 7A4 4 15 11 16 3 13 9 17 17 17 ELEVATION KEYNOTESLa Habra Exterior PlasterFinish: 20/30 Float (Sand) Color: X-40 Dove Gray (Integrated)La Habra Exterior PlasterFinish: 20/30 Float (Sand) Color : X-81583 Belle Glade (Integrated)Coronado Precast Stone Veneer Finish : Chiseled Limestone Color: Silver Ash Firestone CCRRC-Applied Cool RoofFeat.: Thermoplastic Polyolefin (TPO) Color: White Painted Metal FasciaU.S. Aluminum Windows & Doors Model : Standard Aluminum Finish : Bronze Anodized Feat. : Thermally Improved Overhead Doors Garage DoorModel: Standard Aluminum Color : Dark Bronze AnodizedAluminum OverhangColor: Dark Bronze AnodizedAluminum RailingColor: Dark Bronze AnodizedAluminum FenceColor: Dark Bronze AnodizedAluminum Spandrel PanelColor: Dark Bronze AnodizedAluminum DividerColor: Dark Bronze AnodizedMetal PostColor: Dark Bronze AnodizedMetal ScreenColor: Dark Bronze Anodized Roof Eave w/ Integrated Aluminum4"x6" Gutter & DownspoutColor: Dark Anodized Bronze 21346789 10111213141516 Standing Seam Metal Roof 5 Air Conditioning Unit (screened or concealed) 17 Specified Wall Sconce & Unit Number, Typ. 18 Javier GonzalezNo. Cxxxxx Exp. x-xx-17 Robert G. TylerNo. C18812 Exp. 8-31-17 Date Reviewed Drawn ByDescription Do not scale drawings. Contractor shall verifyand be responsible for all dimensions andconditions on the site and Tyler Gonzalez Architects, Inc. shall be notified immediately ofany variations from the dimensions and conditions indicated on these drawings. Drawings, specifications, and other documents,including those in electronic form, prepared by the Architect and the Architect's consultants areInstruments of Service for use solely with respect to this Project. The Architect and theArchitect's consultants shall be deemed theauthors and owners of their respective Instruments of Service and shall retain all common law, statutory and other reserved rights, including copyrights. Visual contact withthese documents constitute prima faciaacceptance of these conditions.Architect of RecordIssue Dates Use of Architect's Drawings2015 Tyler Gonzalez Architects, Inc. c Sheet No.Project No.Scale 139 South Hudson Ave., Suite 300Pasadena, CA 91101626.396.9599 www.TGArchitects.net 1/4" = 1'-0" A-3.5.A Checker Author 2015-09-3015-13 ELEVATIONS - BUILDING D501 N. Santa Anita Ave. Arcadia, CA 91006 SANTA ANITA CONDOMINIUMS 1/4" = 1'-0" 1 North Elev. - Building D 1/4" = 1'-0" 2 South Elev. - Building D No.DescriptionDate Garage Level505' - 11"Second Floor CDEF526' - 2" F Mezzanine Floor515' - 2"Attic CDEF535' - 6"T.O. Roof CDEF539' - 6" A First Floor North511' - 2" 14 25 2525 5 1 10 8 3 11 7 Garage Level505' - 11"Second Floor CDEF526' - 2" F Mezzanine Floor515' - 2"Attic CDEF535' - 6"T.O. Roof CDEF539' - 6" 4'-0"9'-4"11'-0"4'-0" 28'-4 "5'-3" A First Floor North511' - 2" 7A 7A 13 3 2 10 3 8 6 11 3 1 16 ELEVATION KEYNOTESLa Habra Exterior PlasterFinish: 20/30 Float (Sand) Color: X-40 Dove Gray (Integrated)La Habra Exterior PlasterFinish: 20/30 Float (Sand) Color : X-81583 Belle Glade (Integrated)Coronado Precast Stone Veneer Finish : Chiseled Limestone Color: Silver Ash Firestone CCRRC-Applied Cool RoofFeat.: Thermoplastic Polyolefin (TPO) Color: White Painted Metal FasciaU.S. Aluminum Windows & Doors Model : Standard Aluminum Finish : Bronze Anodized Feat. : Thermally Improved Overhead Doors Garage DoorModel: Standard Aluminum Color : Dark Bronze AnodizedAluminum OverhangColor: Dark Bronze AnodizedAluminum RailingColor: Dark Bronze AnodizedAluminum FenceColor: Dark Bronze AnodizedAluminum Spandrel PanelColor: Dark Bronze AnodizedAluminum DividerColor: Dark Bronze AnodizedMetal PostColor: Dark Bronze AnodizedMetal ScreenColor: Dark Bronze Anodized Roof Eave w/ Integrated Aluminum4"x6" Gutter & DownspoutColor: Dark Anodized Bronze 21346789 10111213141516 Standing Seam Metal Roof 5 Air Conditioning Unit (screened or concealed) 17 Specified Wall Sconce & Unit Number, Typ. 18 Javier GonzalezNo. Cxxxxx Exp. x-xx-17 Robert G. TylerNo. C18812 Exp. 8-31-17 Date Reviewed Drawn ByDescription Do not scale drawings. Contractor shall verifyand be responsible for all dimensions andconditions on the site and Tyler Gonzalez Architects, Inc. shall be notified immediately ofany variations from the dimensions and conditions indicated on these drawings. Drawings, specifications, and other documents,including those in electronic form, prepared by the Architect and the Architect's consultants areInstruments of Service for use solely with respect to this Project. The Architect and theArchitect's consultants shall be deemed theauthors and owners of their respective Instruments of Service and shall retain all common law, statutory and other reserved rights, including copyrights. Visual contact withthese documents constitute prima faciaacceptance of these conditions.Architect of RecordIssue Dates Use of Architect's Drawings2015 Tyler Gonzalez Architects, Inc. c Sheet No.Project No.Scale 139 South Hudson Ave., Suite 300Pasadena, CA 91101626.396.9599 www.TGArchitects.net 1/4" = 1'-0" A-3.5.B Checker Author 2015-09-3015-13 ELEVATIONS - BUILDING D501 N. Santa Anita Ave. Arcadia, CA 91006 SANTA ANITA CONDOMINIUMS 1/4" = 1'-0" 1 East Elev. - Building D 1/4" = 1'-0" 2 West Elev. - Building D No.DescriptionDate Garage Level505' - 11"Second Floor CDEF526' - 2" 22 23 Mezzanine Floor515' - 2"Attic CDEF535' - 6"T.O. Roof CDEF539' - 6" 4'-7"11'-0"9'-4"4'-0" 4'-8"28'-11" First Floor East510' - 7" 10 13 3 3 3 3 3 3 3 3 12 8 1 2 4 6 11 17 7 Garage Level505' - 11"Second Floor CDEF526' - 2" 22 23 Mezzanine Floor515' - 2"Attic CDEF535' - 6"T.O. Roof CDEF539' - 6"First Floor East510' - 7" 3 11 1 17 7 5 6 4 11 8 12 3 3 6 11 Second Floor CDEF526' - 2"Mezzanine Floor515' - 2"Attic CDEF535' - 6"T.O. Roof CDEF539' - 6"First Floor East510' - 7" 20 11 33 26 3 12 1 8 11 5 6 4 ELEVATION KEYNOTESLa Habra Exterior PlasterFinish: 20/30 Float (Sand) Color: X-40 Dove Gray (Integrated)La Habra Exterior PlasterFinish: 20/30 Float (Sand) Color : X-81583 Belle Glade (Integrated)Coronado Precast Stone Veneer Finish : Chiseled Limestone Color: Silver Ash Firestone CCRRC-Applied Cool RoofFeat.: Thermoplastic Polyolefin (TPO) Color: White Painted Metal FasciaU.S. Aluminum Windows & Doors Model : Standard Aluminum Finish : Bronze Anodized Feat. : Thermally Improved Overhead Doors Garage DoorModel: Standard Aluminum Color : Dark Bronze AnodizedAluminum OverhangColor: Dark Bronze AnodizedAluminum RailingColor: Dark Bronze AnodizedAluminum FenceColor: Dark Bronze AnodizedAluminum Spandrel PanelColor: Dark Bronze AnodizedAluminum DividerColor: Dark Bronze AnodizedMetal PostColor: Dark Bronze AnodizedMetal ScreenColor: Dark Bronze Anodized Roof Eave w/ Integrated Aluminum4"x6" Gutter & DownspoutColor: Dark Anodized Bronze 21346789 10111213141516 Standing Seam Metal Roof 5 Air Conditioning Unit (screened or concealed) 17 Specified Wall Sconce & Unit Number, Typ. 18 Javier GonzalezNo. Cxxxxx Exp. x-xx-17 Robert G. TylerNo. C18812 Exp. 8-31-17 Date Reviewed Drawn ByDescription Do not scale drawings. Contractor shall verifyand be responsible for all dimensions andconditions on the site and Tyler Gonzalez Architects, Inc. shall be notified immediately ofany variations from the dimensions and conditions indicated on these drawings. Drawings, specifications, and other documents,including those in electronic form, prepared by the Architect and the Architect's consultants areInstruments of Service for use solely with respect to this Project. The Architect and theArchitect's consultants shall be deemed theauthors and owners of their respective Instruments of Service and shall retain all common law, statutory and other reserved rights, including copyrights. Visual contact withthese documents constitute prima faciaacceptance of these conditions.Architect of RecordIssue Dates Use of Architect's Drawings2015 Tyler Gonzalez Architects, Inc. c Sheet No.Project No.Scale 139 South Hudson Ave., Suite 300Pasadena, CA 91101626.396.9599 www.TGArchitects.net 1/4" = 1'-0" A-3.6.A Checker Author 2015-09-3015-13 ELEVATIONS - BUILDING E501 N. Santa Anita Ave. Arcadia, CA 91006 SANTA ANITA CONDOMINIUMS 1/4" = 1'-0" 1 North Elev. - Building E 1/4" = 1'-0" 2 South Elev. - Building E 1/4" = 1'-0" 3 Southeast Elev. - Building E No.DescriptionDate Second Floor CDEF526' - 2" E Mezzanine Floor515' - 2"Attic CDEF535' - 6"T.O. Roof CDEF539' - 6" B C D 4 A-4.1 4 A-4.0 A First Floor East510' - 7" 11A 11A 8 8 3 3 16 21 20 20 3 3 12 3 17 4 1 18 12 7 6 2 5 108 1113 8 3 Garage Level505' - 11"Second Floor CDEF526' - 2" E Mezzanine Floor515' - 2"Attic CDEF535' - 6"T.O. Roof CDEF539' - 6" B C D 4'-0"9'-4"11'-0"4'-7" 28'-11"4'-8" 4 A-4.1 4 A-4.0 A First Floor East510' - 7" 17 17 17 17 6 88 7 7 7 4 4 4 4 4 14 14 3 3 7A 7A 25 7A 7A4 4 2 4 6 7 1 17 108 13 5 1112 3 9 ELEVATION KEYNOTESLa Habra Exterior PlasterFinish: 20/30 Float (Sand) Color: X-40 Dove Gray (Integrated)La Habra Exterior PlasterFinish: 20/30 Float (Sand) Color : X-81583 Belle Glade (Integrated)Coronado Precast Stone Veneer Finish : Chiseled Limestone Color: Silver Ash Firestone CCRRC-Applied Cool RoofFeat.: Thermoplastic Polyolefin (TPO) Color: White Painted Metal FasciaU.S. Aluminum Windows & Doors Model : Standard Aluminum Finish : Bronze Anodized Feat. : Thermally Improved Overhead Doors Garage DoorModel: Standard Aluminum Color : Dark Bronze AnodizedAluminum OverhangColor: Dark Bronze AnodizedAluminum RailingColor: Dark Bronze AnodizedAluminum FenceColor: Dark Bronze AnodizedAluminum Spandrel PanelColor: Dark Bronze AnodizedAluminum DividerColor: Dark Bronze AnodizedMetal PostColor: Dark Bronze AnodizedMetal ScreenColor: Dark Bronze Anodized Roof Eave w/ Integrated Aluminum4"x6" Gutter & DownspoutColor: Dark Anodized Bronze 21346789 10111213141516 Standing Seam Metal Roof 5 Air Conditioning Unit (screened or concealed) 17 Specified Wall Sconce & Unit Number, Typ. 18 Javier GonzalezNo. Cxxxxx Exp. x-xx-17 Robert G. TylerNo. C18812 Exp. 8-31-17 Date Reviewed Drawn ByDescription Do not scale drawings. Contractor shall verifyand be responsible for all dimensions andconditions on the site and Tyler Gonzalez Architects, Inc. shall be notified immediately ofany variations from the dimensions and conditions indicated on these drawings. Drawings, specifications, and other documents,including those in electronic form, prepared by the Architect and the Architect's consultants areInstruments of Service for use solely with respect to this Project. The Architect and theArchitect's consultants shall be deemed theauthors and owners of their respective Instruments of Service and shall retain all common law, statutory and other reserved rights, including copyrights. Visual contact withthese documents constitute prima faciaacceptance of these conditions.Architect of RecordIssue Dates Use of Architect's Drawings2015 Tyler Gonzalez Architects, Inc. c Sheet No.Project No.Scale 139 South Hudson Ave., Suite 300Pasadena, CA 91101626.396.9599 www.TGArchitects.net 1/4" = 1'-0" A-3.6.B Checker Author 2015-09-3015-13 ELEVATIONS - BUILDING E501 N. Santa Anita Ave. Arcadia, CA 91006 SANTA ANITA CONDOMINIUMS 1/4" = 1'-0" 2 East Elev. - Building E 1/4" = 1'-0" 1 West Elev. - Building E No.DescriptionDate First Floor South510' - 0"Garage Level505' - 11"Second Floor CDEF526' - 2" 13 Mezzanine Floor515' - 2"Attic CDEF535' - 6"T.O. Roof CDEF539' - 6" 9 10 11 12 M ATCHLINE 5'-2"11'-0"9'-4"4'-0" 4'-1"29'-6" 2 A-4.1 3 A-4.117 17 17 17 10 10 10 4 4 4 4 4 4 14 14 7 7 7A 7A 7A 7A 7 4 4 4 7 7 7 4 6 1 8 13 2 11 16 4 13 3 9 First Floor South510' - 0" First Floor South510' - 0"Second Floor AB521' - 0" Garage Level505' - 11" Garage AB 509' - 4 3/4" Second Floor CDEF526' - 2" Attic AB 531' - 0"T.O. Roof AB536' - 0" 6 7 Mezzanine Floor515' - 2"Attic CDEF535' - 6"T.O. Roof CDEF539' - 6" 8 9M A TCH LINE 1 A-4.1 17 17 17 10 4 4 14 7 7 9 11 8 3 3 11 8A 7 7 7 7 4 4 4 4 5 6 2 8 1 11 16 13 3 9 1012 ELEVATION KEYNOTESLa Habra Exterior PlasterFinish: 20/30 Float (Sand) Color: X-40 Dove Gray (Integrated)La Habra Exterior PlasterFinish: 20/30 Float (Sand) Color : X-81583 Belle Glade (Integrated)Coronado Precast Stone Veneer Finish : Chiseled Limestone Color: Silver Ash Firestone CCRRC-Applied Cool RoofFeat.: Thermoplastic Polyolefin (TPO) Color: White Painted Metal FasciaU.S. Aluminum Windows & Doors Model : Standard Aluminum Finish : Bronze Anodized Feat. : Thermally Improved Overhead Doors Garage DoorModel: Standard Aluminum Color : Dark Bronze AnodizedAluminum OverhangColor: Dark Bronze AnodizedAluminum RailingColor: Dark Bronze AnodizedAluminum FenceColor: Dark Bronze AnodizedAluminum Spandrel PanelColor: Dark Bronze AnodizedAluminum DividerColor: Dark Bronze AnodizedMetal PostColor: Dark Bronze AnodizedMetal ScreenColor: Dark Bronze Anodized Roof Eave w/ Integrated Aluminum4"x6" Gutter & DownspoutColor: Dark Anodized Bronze 21346789 10111213141516 Standing Seam Metal Roof 5 Air Conditioning Unit (screened or concealed) 17 Specified Wall Sconce & Unit Number, Typ. 18 Javier GonzalezNo. Cxxxxx Exp. x-xx-17 Robert G. TylerNo. C18812 Exp. 8-31-17 Date Reviewed Drawn ByDescription Do not scale drawings. Contractor shall verifyand be responsible for all dimensions andconditions on the site and Tyler Gonzalez Architects, Inc. shall be notified immediately ofany variations from the dimensions and conditions indicated on these drawings. Drawings, specifications, and other documents,including those in electronic form, prepared by the Architect and the Architect's consultants areInstruments of Service for use solely with respect to this Project. The Architect and theArchitect's consultants shall be deemed theauthors and owners of their respective Instruments of Service and shall retain all common law, statutory and other reserved rights, including copyrights. Visual contact withthese documents constitute prima faciaacceptance of these conditions.Architect of RecordIssue Dates Use of Architect's Drawings2015 Tyler Gonzalez Architects, Inc. c Sheet No.Project No.Scale 139 South Hudson Ave., Suite 300Pasadena, CA 91101626.396.9599 www.TGArchitects.net 1/4" = 1'-0" A-3.7.A Checker Author 2015-09-3015-13 ELEVATIONS - BUILDING F501 N. Santa Anita Ave. Arcadia, CA 91006 SANTA ANITA CONDOMINIUMS 1/4" = 1'-0" 1 North Elev. - Building F East 1/4" = 1'-0" 2 North Elev. - Building F West No.DescriptionDate First Floor South510' - 0" First Floor South510' - 0" Second Floor AB521' - 0"Garage AB 509' - 4 3/4" Second Floor CDEF526' - 2" Attic AB 531' - 0"T.O. Roof AB536' - 0" 6 7 Mezzanine Floor515' - 2"Attic CDEF535' - 6"T.O. Roof CDEF539' - 6" 8 9 MA TCHLINE 5'-0"10'-0"11'-0" 26'-0"71/4" 4 '-0"9 '-4"11 '-0 "5'-2" 29 '-6" 1 A-4.1 7 8 12 21 3 22 15 16 3 129 7A 8 7A 7A 7A 3 2 2 13 8 7A 2 10 6 11 4 8 3 16 First Floor South510' - 0"Second Floor CDEF526' - 2" 13 Mezzanine Floor515' - 2"Attic CDEF535' - 6"T.O. Roof CDEF539' - 6" 9 10 11 12 MATCH LINE 2 A-4.1 3 A-4.1 8 8 8 20 20 21 3 3 3 22 7A 8 8 16 15 11A 11A 8 27 4 11 4 10 2 5 108 1113 15 ELEVATION KEYNOTESLa Habra Exterior PlasterFinish: 20/30 Float (Sand) Color: X-40 Dove Gray (Integrated)La Habra Exterior PlasterFinish: 20/30 Float (Sand) Color : X-81583 Belle Glade (Integrated)Coronado Precast Stone Veneer Finish : Chiseled Limestone Color: Silver Ash Firestone CCRRC-Applied Cool RoofFeat.: Thermoplastic Polyolefin (TPO) Color: White Painted Metal FasciaU.S. Aluminum Windows & Doors Model : Standard Aluminum Finish : Bronze Anodized Feat. : Thermally Improved Overhead Doors Garage DoorModel: Standard Aluminum Color : Dark Bronze AnodizedAluminum OverhangColor: Dark Bronze AnodizedAluminum RailingColor: Dark Bronze AnodizedAluminum FenceColor: Dark Bronze AnodizedAluminum Spandrel PanelColor: Dark Bronze AnodizedAluminum DividerColor: Dark Bronze AnodizedMetal PostColor: Dark Bronze AnodizedMetal ScreenColor: Dark Bronze Anodized Roof Eave w/ Integrated Aluminum4"x6" Gutter & DownspoutColor: Dark Anodized Bronze 21346789 10111213141516 Standing Seam Metal Roof 5 Air Conditioning Unit (screened or concealed) 17 Specified Wall Sconce & Unit Number, Typ. 18 Javier GonzalezNo. Cxxxxx Exp. x-xx-17 Robert G. TylerNo. C18812 Exp. 8-31-17 Date Reviewed Drawn ByDescription Do not scale drawings. Contractor shall verifyand be responsible for all dimensions andconditions on the site and Tyler Gonzalez Architects, Inc. shall be notified immediately ofany variations from the dimensions and conditions indicated on these drawings. Drawings, specifications, and other documents,including those in electronic form, prepared by the Architect and the Architect's consultants areInstruments of Service for use solely with respect to this Project. The Architect and theArchitect's consultants shall be deemed theauthors and owners of their respective Instruments of Service and shall retain all common law, statutory and other reserved rights, including copyrights. Visual contact withthese documents constitute prima faciaacceptance of these conditions.Architect of RecordIssue Dates Use of Architect's Drawings2015 Tyler Gonzalez Architects, Inc. c Sheet No.Project No.Scale 139 South Hudson Ave., Suite 300Pasadena, CA 91101626.396.9599 www.TGArchitects.net 1/4" = 1'-0" A-3.7.B Checker Author 2015-09-3015-13 ELEVATIONS - BUILDING F501 N. Santa Anita Ave. Arcadia, CA 91006 SANTA ANITA CONDOMINIUMS 1/4" = 1'-0" 1 South Elev. - Building F West 1/4" = 1'-0" 2 South Elev. - Building F East No.DescriptionDate First Floor South510' - 0"Garage Level505' - 11"Second Floor CDEF526' - 2" G H Mezzanine Floor515' - 2"Attic CDEF535' - 6"T.O. Roof CDEF539' - 6" 4'-0"9'-4"11'-0"5'-2" 29'-6 "4'-1" 2 A-4.2 24 7 5 1 6 8 3 151112 5 5 24 24 First Floor South510' - 0"Second Floor AB521' - 0"Garage AB 509' - 4 3/4"Attic AB 531' - 0"T.O. Roof AB536' - 0" G H 5'-0"10'-0"11'-0" 26'-0"71 /4" 2 2 13 3 6 11 4 2 3 1 8 5 6 10127 ELEVATION KEYNOTESLa Habra Exterior PlasterFinish: 20/30 Float (Sand) Color: X-40 Dove Gray (Integrated)La Habra Exterior PlasterFinish: 20/30 Float (Sand) Color : X-81583 Belle Glade (Integrated)Coronado Precast Stone Veneer Finish : Chiseled Limestone Color: Silver Ash Firestone CCRRC-Applied Cool RoofFeat.: Thermoplastic Polyolefin (TPO) Color: White Painted Metal FasciaU.S. Aluminum Windows & Doors Model : Standard Aluminum Finish : Bronze Anodized Feat. : Thermally Improved Overhead Doors Garage DoorModel: Standard Aluminum Color : Dark Bronze AnodizedAluminum OverhangColor: Dark Bronze AnodizedAluminum RailingColor: Dark Bronze AnodizedAluminum FenceColor: Dark Bronze AnodizedAluminum Spandrel PanelColor: Dark Bronze AnodizedAluminum DividerColor: Dark Bronze AnodizedMetal PostColor: Dark Bronze AnodizedMetal ScreenColor: Dark Bronze Anodized Roof Eave w/ Integrated Aluminum4"x6" Gutter & DownspoutColor: Dark Anodized Bronze 21346789 10111213141516 Standing Seam Metal Roof 5 Air Conditioning Unit (screened or concealed) 17 Specified Wall Sconce & Unit Number, Typ. 18 Javier GonzalezNo. Cxxxxx Exp. x-xx-17 Robert G. TylerNo. C18812 Exp. 8-31-17 Date Reviewed Drawn ByDescription Do not scale drawings. Contractor shall verifyand be responsible for all dimensions andconditions on the site and Tyler Gonzalez Architects, Inc. shall be notified immediately ofany variations from the dimensions and conditions indicated on these drawings. Drawings, specifications, and other documents,including those in electronic form, prepared by the Architect and the Architect's consultants areInstruments of Service for use solely with respect to this Project. The Architect and theArchitect's consultants shall be deemed theauthors and owners of their respective Instruments of Service and shall retain all common law, statutory and other reserved rights, including copyrights. Visual contact withthese documents constitute prima faciaacceptance of these conditions.Architect of RecordIssue Dates Use of Architect's Drawings2015 Tyler Gonzalez Architects, Inc. c Sheet No.Project No.Scale 139 South Hudson Ave., Suite 300Pasadena, CA 91101626.396.9599 www.TGArchitects.net 1/4" = 1'-0" A-3.7.C Checker Author 2015-09-3015-13 ELEVATIONS - BUILDING F501 N. Santa Anita Ave. Arcadia, CA 91006 SANTA ANITA CONDOMINIUMS 1/4" = 1'-0" 1 East Elev. - Building F 1/4" = 1'-0" 2 West Elev. - Building F No.DescriptionDate First Floor South510' - 0"Second Floor AB521' - 0"Garage AB 509' - 4 3/4"Attic AB 531' - 0"T.O. Roof AB536' - 0" K L 5'-0"10'-0"11'-0 " 26'-0 "71/4" LIVING DINING KITCHENBEDRM. 3 BEDRM. 2 CL 3'-6" Varie s First Floor South510' - 0"Second Floor AB521' - 0"Garage AB 509' - 4 3/4"Attic AB 531' - 0"T.O. Roof AB536' - 0" L J 5'-0"10'-0"11'-0" 26'-0"71 /4" 3'-6" GARAGE ENTRY HALL BEDRM. 3 STOR. Varies M Garage Level505' - 11"Second Floor CDEF526' - 2" F Mezzanine Floor515' - 2"Attic CDEF535' - 6"T.O. Roof CDEF539' - 6" 4'-0"9'-4"11'-0"4'-0" 28'-4"5'-3" LIVING DINING KITCHEN GARAGE BEDRM. 3 HALL M. BEDRM. A 1 A-4.2 First Floor North511' - 2"First Floor South510' - 0"Second Floor AB521' - 0"Attic AB 531' - 0"T.O. Roof AB536' - 0" F A 1 A-4.2 5'-0"10'-0"11'-0" 26'-0" KITCHEN DINING LIVINGBEDRM. 2 CL BEDRM. 3 BATH Javier GonzalezNo. Cxxxxx Exp. x-xx-17 Robert G. TylerNo. C18812 Exp. 8-31-17 Date Reviewed Drawn ByDescription Do not scale drawings. Contractor shall verifyand be responsible for all dimensions andconditions on the site and Tyler Gonzalez Architects, Inc. shall be notified immediately ofany variations from the dimensions and conditions indicated on these drawings. Drawings, specifications, and other documents,including those in electronic form, prepared by the Architect and the Architect's consultants areInstruments of Service for use solely with respect to this Project. The Architect and theArchitect's consultants shall be deemed theauthors and owners of their respective Instruments of Service and shall retain all common law, statutory and other reserved rights, including copyrights. Visual contact withthese documents constitute prima faciaacceptance of these conditions.Architect of RecordIssue Dates Use of Architect's Drawings2015 Tyler Gonzalez Architects, Inc. c Sheet No.Project No.Scale 139 South Hudson Ave., Suite 300Pasadena, CA 91101626.396.9599 www.TGArchitects.net 1/4" = 1'-0" A-4.0 Checker Author 2015-09-3015-13 SECTIONS501 N. Santa Anita Ave. Arcadia, CA 91006 SANTA ANITA CONDOMINIUMS 1/4" = 1'-0" 1 Section - Building A 1/4" = 1'-0" 2 Section - Building B 1/4" = 1'-0" 4 Section 2 - Building C No.DescriptionDate 1/4" = 1'-0" 5 Section 1 - Building C - DD First Floor South510' - 0"Second Floor AB521' - 0"Garage AB 509' - 4 3/4"Attic AB 531' - 0"T.O. Roof AB536' - 0" G H BEDRM. 1 HALL ENTRY STUDY BEDRM. 2 3'-6" 5'-0"10'-0"11'-0" 26'-0"71/4" First Floor South510' - 0"Garage Level505' - 11"Second Floor CDEF526' - 2" G H Mezzanine Floor515' - 2"Attic CDEF535' - 6"T.O. Roof CDEF539' - 6" BEDRM. 3 HALL M. BATHPWDR. LAUNDRY 4'-0"9'-4"11'-0"5'-2" 29'-6"4'-1" 3'-6" First Floor South510' - 0"Garage Level505' - 11"Second Floor CDEF526' - 2" G H Mezzanine Floor515' - 2"Attic CDEF535' - 6"T.O. Roof CDEF539' - 6" M. BEDRM. HALL BEDRM. 3KITCHEN DINING LIVING GARAGE 4'-0"9'-4"11'-0"5'-2" 29'-6"4'-1" 2 A-4.2 Garage Level505' - 11"Second Floor CDEF526' - 2" 22 23 Mezzanine Floor515' - 2"Attic CDEF535' - 6"T.O. Roof CDEF539' - 6" ENTRY W.I.C. LAUNDRY BATH CL BEDRM. 3 PWDR.GARAGE HALL 4'-0"9'-4"11'-0"4'-7" 28'-11"4'-8" 3'-6" First Floor East510' - 7" Javier GonzalezNo. Cxxxxx Exp. x-xx-17 Robert G. TylerNo. C18812 Exp. 8-31-17 Date Reviewed Drawn ByDescription Do not scale drawings. Contractor shall verifyand be responsible for all dimensions andconditions on the site and Tyler Gonzalez Architects, Inc. shall be notified immediately ofany variations from the dimensions and conditions indicated on these drawings. Drawings, specifications, and other documents,including those in electronic form, prepared by the Architect and the Architect's consultants areInstruments of Service for use solely with respect to this Project. The Architect and theArchitect's consultants shall be deemed theauthors and owners of their respective Instruments of Service and shall retain all common law, statutory and other reserved rights, including copyrights. Visual contact withthese documents constitute prima faciaacceptance of these conditions.Architect of RecordIssue Dates Use of Architect's Drawings2015 Tyler Gonzalez Architects, Inc. c Sheet No.Project No.Scale 139 South Hudson Ave., Suite 300Pasadena, CA 91101626.396.9599 www.TGArchitects.net 1/4" = 1'-0" A-4.1 Checker Author 2015-09-3015-13 SECTIONS501 N. Santa Anita Ave. Arcadia, CA 91006 SANTA ANITA CONDOMINIUMS 1/4" = 1'-0" 1 Section 1 - Building F 1/4" = 1'-0" 2 Section 2 - Building F 1/4" = 1'-0" 3 Section 3 - Building F 1/4" = 1'-0" 4 Section - Building E No.DescriptionDate First Floor South510' - 0"Second Floor AB521' - 0" Garage Level505' - 11" Garage AB 509' - 4 3/4" Second Floor CDEF526' - 2" Attic AB 531' - 0"T.O. Roof AB536' - 0" 17 14 Mezzanine Floor515' - 2"Attic CDEF535' - 6"T.O. Roof CDEF539' - 6" 15 16 - --- 4 A-4.0 2 A-4.1 5'-0"10'-0"11'-0" 26'-0"71/4" 4'-0"9'-4"11'-0"4'-0" 28'-4 "5'-3" M. BEDRM.GARAGE KITCHENBEDRM. 3 BATH HALL LINEN BEDRM. 2 BEDRM. 2 LINEN HALL BATH DINING DININGGARAGE GARAGE First Floor North511' - 2" 5 A-4.0 First Floor South510' - 0"Garage Level505' - 11"Second Floor CDEF526' - 2" 13 Mezzanine Floor515' - 2"Attic CDEF535' - 6"T.O. Roof CDEF539' - 6" 12 3 A-4.1 M. BATH 4'-0"9'-4"11'-0"5'-2" 29'-6"4'-1" Javier GonzalezNo. Cxxxxx Exp. x-xx-17 Robert G. TylerNo. C18812 Exp. 8-31-17 Date Reviewed Drawn ByDescription Do not scale drawings. Contractor shall verifyand be responsible for all dimensions andconditions on the site and Tyler Gonzalez Architects, Inc. shall be notified immediately ofany variations from the dimensions and conditions indicated on these drawings. Drawings, specifications, and other documents,including those in electronic form, prepared by the Architect and the Architect's consultants areInstruments of Service for use solely with respect to this Project. The Architect and theArchitect's consultants shall be deemed theauthors and owners of their respective Instruments of Service and shall retain all common law, statutory and other reserved rights, including copyrights. Visual contact withthese documents constitute prima faciaacceptance of these conditions.Architect of RecordIssue Dates Use of Architect's Drawings2015 Tyler Gonzalez Architects, Inc. c Sheet No.Project No.Scale 139 South Hudson Ave., Suite 300Pasadena, CA 91101626.396.9599 www.TGArchitects.net 1/4" = 1'-0" A-4.2 Checker Author 2015-09-3015-13 SECTIONS501 N. Santa Anita Ave. Arcadia, CA 91006 SANTA ANITA CONDOMINIUMS 1/4" = 1'-0" 1 Section 3 - Building C No.DescriptionDate 1/4" = 1'-0" 2 Section 4 - Building F SeeS chedule See Schedule Window Type 1 (Skylight)Window Types 3 & 3ASee Schedule Window Type 2See Schedule Window Types 7 & 7ASee Schedule Window Type 23 Window Type 10 2'-1" See Schedule SeeSchedu le SeeS chedule See Schedule Window Type 15 Window Types 8 & 8ASee Schedule - 2 Equal Lites 2'-1" SeeSchedule See Schedule - 2 Equal LitesWindow Type 11 Window Types 9 & 9ASee Schedule - 3 Equal Lites 2'-1"3'-21/2" Window Type 25 Window Type 26 2'-1" SeeS chedule See Schedule - 3 Equal LitesWindow Type 12 2'-1" SeeS chedule See Schedule - 3 Equal LitesWindow Type 13Window Type 142'-1" SeeS chedule Eq Eq See Schedule 2'-1"2'-1" SeeSchedu le Window Type 20 See Schedule - 3 Equal Lites Window Type 27 2'-1" See Schedule - 4 Equal Lites 2'-1" SeeS chedule Eq Eq Window Type 21 6' - 0" See Schedule Window Type 22 2'-1"2'-1" SeeS chedule 2' - 6" Door Type 1Door Type 2Door Type 3Door Type 5 SeeS chedule See Schedule SeeS chedule SeeS chedule SeeS chedule See Schedule See Schedule See Schedule SeeSchedule See ScheduleDoor Type 6Door Types 7 & 7ADoor Type 8SeeS chedule2'-1" See Schedule SeeS chedule2'-1" See Schedule 2'-1"1'-10" See Schedule 2' - 8" SeeS chedule SeeS chedule Door Type 10 See Schedule Eq Eq 2'-1"2'-1" SeeS chedule Door Types 11 & 11ADoor Type 122'-1"2'-1" SeeSchedule Eq Eq See Schedule See Schedule See Schedule SeeSchedule 3'-21/2"2'-1" SeeSchedule Eq Eq See ScheduleSee Schedule SeeS chedule2'-1" Door Type 13 Door Type 9 2'-1"SeeSchedule SeeS chedule See Schedule - 2 Equal Lites See Schedule SeeS chedule 2'-1"1'-10" SeeS chedule Eq See Schedule Eq Door Type 14 2'-1"2'-1" SeeS chedule SeeSchedule Eq See Schedule Eq See ScheduleDoor Type 15Door Type 162'-1"2'-1" SeeSchedule Eq See Schedule Eq See Schedule SeeS chedule See ScheduleDoor Type 17 5'-11 "2'-1" SeeS chedule See Schedule - 2 Equal LitesWindow Type 18Window Type 19 SeeS chedule SeeSchedule See Schedule See Schedule SeeSchedu le 3" MetalOverhangSeeS chedule 3" MetalOverhang 3" MetalOverhang See Schedule - 2 Equal Lites SeeS chedule See Schedule SeeS chedule See Schedule - 2 Equal LitesWindow Type 4Window Type 5 See Schedule - 3 Equal Lites Window Type 24 SeeSchedule Eq 3' - 0" Eq See Schedule SeeS chedu leSeeS chedule See Schedule - 3 Equal Lites 3" MetalOverhang 2'-1"5'-11" SeeS chedule See Schedule SeeS chedu le See Schedule - 2 Equal Lites S eeS chedule See Schedule - 3 Equal LitesWindow Type 6 Door Type 4 SeeSchedule See Schedule SeeSchedule SeeS chedule See Schedule 3" MetalOverhang 3" MetalOverhang See Schedule 3" MetalOverhang Eq See Schedule Eq See Schedule SeeSchedule SeeSchedule OP OPOP OP OP OP OP OP OP OP OP OP OP OP OP OP OP OP OP OP OP OP OP OP OP OP OP OP OP OP OP OP OP OP OP OP OP OP OP OP OP OP OP OP OP OP = Operable Window OP OP OP OP Window Type 17 Window Type 16 SeeS chedule 5'-11" See Schedule See Schedule - 2 Equal Lites SeeS chedule 5'-11 " See Schedule SeeS chedule SeeS chedu le See Schedule Eq 6' - 0" Eq Wd. Sheathing per Struct.Wd. Header per Struct.Specified 7/8" Cement Plaster(measured from the face of sheathing)over metal lath. Plaster mix 1:4 forscratch coat and 1:5 for brown coat,by volume, cement to sand.Liquid-applied moisture barriersystem: Dupont Tyvek Fluid-Applied WB, or approved equal.Specified Door/Window FlashingSystem w/ Drip EdgePlaster J-Casing R-19 Batt Insulationper Title 24, Typ. 5/8" Type X GypsumWallboard applied at parallel or right angles tostuds with 1-1/4" drywallscrews 8" o.c. Cont. Sealer & Backer RodSpecified Window System Cont. Sealer & Backer RodCorner Bead Window Jamb Beyond 3 3/8" 7 1/2" Javier GonzalezNo. Cxxxxx Exp. x-xx-17 Robert G. TylerNo. C18812 Exp. 8-31-17 Date Reviewed Drawn ByDescription Do not scale drawings. Contractor shall verifyand be responsible for all dimensions andconditions on the site and Tyler Gonzalez Architects, Inc. shall be notified immediately ofany variations from the dimensions and conditions indicated on these drawings. Drawings, specifications, and other documents,including those in electronic form, prepared by the Architect and the Architect's consultants areInstruments of Service for use solely with respect to this Project. The Architect and theArchitect's consultants shall be deemed theauthors and owners of their respective Instruments of Service and shall retain all common law, statutory and other reserved rights, including copyrights. Visual contact withthese documents constitute prima faciaacceptance of these conditions.Architect of RecordIssue Dates Use of Architect's Drawings2015 Tyler Gonzalez Architects, Inc. c Sheet No.Project No.Scale 139 South Hudson Ave., Suite 300Pasadena, CA 91101626.396.9599 www.TGArchitects.netAs indicated A-8.0 Checker Author 2015-09-3015-13 WINDOW & DOOR SCHEDULES& TYPES501 N. Santa Anita Ave. Arcadia, CA 91006 SANTA ANITA CONDOMINIUMS WINDOW SCHEDULE Type MarkWidthHeightCountHeadJambMullionSillComments138' - 4"7' - 9 1/2"3147' - 0 3/4"7' - 9 1/2"10152' - 11"10' - 9 1/2"1162' - 11"11' - 7 1/2"1175' - 7 1/2"11' - 7 1/2"1182' - 11"13' - 6"2195' - 7 1/2"13' - 6"2208' - 4"9' - 8"92111' - 0 1/2"9' - 8"42211' - 10"9' - 8"2232' - 11"2' - 1"3245' - 7 1/2"2' - 1"4258' - 4"2' - 1"15268' - 4"2' - 1"22711' - 10"2' - 1"1 WINDOW SCHEDULE Type MarkWidthHeightCountHeadJambMullionSillComments13' - 0"3' - 0"1221' - 2"2' - 10"1031' - 9"4' - 0"513A1' - 9"4' - 0"642' - 11"5' - 0"3355' - 7 1/2"5' - 0"368' - 4"5' - 0"472' - 11"5' - 11"18 7A2' - 11"5' - 11"2885' - 7 1/2"5' - 11"138A5' - 7 1/2"5' - 11"798' - 4"5' - 11"3 9A8' - 4"5' - 11"3102' - 11"7' - 9 1/2"1115' - 7 1/2"7' - 9 1/2"3128' - 4"7' - 9 1/2"5 EXTERIOR DOOR SCHEDULE Type MarkFunctionWidthHeightDoor HeightCountThicknessSidelightTransomHeadJambTransom/SidelightSillComments6Exterior3' - 5"7' - 5 1/2"47Exterior3' - 5"8' - 11"6' - 10"27AExterior3' - 5"8' - 11"6' - 10"18Exterior3' - 5"9' - 4"7' - 3"179Exterior6' - 5"8' - 11"6' - 10"1 10Exterior5' - 10 1/2"8' - 8"6' - 10"1211Exterior8' - 4"8' - 11"6' - 10"311AExterior8' - 4"8' - 11"6' - 10"512Exterior6' - 0"9' - 4"7' - 3"313Exterior8' - 4"10' - 9 1/2"6' - 10"314Exterior9' - 6"8' - 8"6' - 10"215Exterior11' - 0 1/2"8' - 11"6' - 10"416Exterior11' - 10"8' - 11"6' - 10"417Exterior16' - 2"7' - 1"200' - 1 1/2" No.DescriptionDate INTERIOR DOOR SCHEDULE Type MarkFunctionWidthHeightCountThicknessHeadJambTransom/SidelightSillComments26Interior20' - 2"1Interior2' - 6"6' - 8"360' - 2"2Interior2' - 10"6' - 8"1920' - 2"3Interior3' - 0"6' - 8"340' - 2"4Interior4' - 0"6' - 8"30' - 2"5Interior5' - 8"6' - 8"290' - 2"12Interior20' - 2" 3" = 1'-0"1 Detail @ Window Head, Casement, Outswing DN DN DN DN DN x Rosemarinus officinalis 'Huntington Carpet' Combined Plant Palette Shrubs Symbol Quantity - Size Botanical Name Comon Name Notes X - 15 Gallon Caesalpinia pulcherrima Dwarf Poinciana Red Bird of Paradise X - 15 Gallon Leucadendron 'Safari Sunset' Safari Conebush Vines Water: M/L Water: M/L X - 5 Gallon X- 15 Gallon Coleonema 'Sunset Gold' Sunset Gold Diosma Sunset Golden Breath of Heaven Water: M X - 5 Gallon Lantana x 'Lemon Swirl' Variegated Yellow Lantana Water: M/L X - 5 Gallon Salvia leucantha Mexican Sage Water: M/L Ground Cover Legend X - 5 Gallon Bougainvilla 'Crimson Jewel' Red Flowering Low Bougainvilla X - 5 Gallon Westringia 'Wynyabbie Highlight'Variegated Australian Rosemary Water: M/L Water: M/L X - 5 Gallon Lantana x 'New Gold' Yellow Trailing Lantana Water: M/L Perennials X - 5 Gallon Liriope muscari 'Silvery Sunproof' Variegated Lily Turf Water: M X - 5 Gallon Liriope 'Gigantea' Big Blue Lily Turf Water: M X - 5 Gallon Tulbaghia violacea Society Garlic Water: M Symbol Quantity - Size Botanical Name Comon Name Notes Symbol Quantity - Size Botanical Name Comon Name Notes Espalliers X - 15 Gallon Podocarpus gracilior elongata Espaliered Fern Pine Water: M X - 15 Gallon Punica granatum 'Nana' Dwarf Pomegranite Water: M Grasses X - 1 Gallon Festuca ovina 'Siskiyou Blue' Siskiyou Blue Fescue Water: M X - 5 Gallon Muhlenbergia rigens Deer Grass Water: M/L X - 5 Gallon Nasella tenuissima Mexican Feather Grass Water: L/VL Flatted @ 9" On Center Baccharis pilularis pilularis 'Pigeon Point' Dwarf Coyote Bush Water: M/L Flatted @9" On Center Aptenia cordifolia 'Red Apple' Red Apple, Baby Sunrose Water: L/VL 1 Gallon @36" On Center Huntington Carpet Rosemary Water: M/L Flatted @6" On Center Dymondia margaretae Silver Carpet Water: L/VL 4" Pots or 1 Gal @12" On Center Geranium x cantabrigiensis 'Biokovo' Biokovo Cransbill (White) Water: M Flatted @12" On Center Geranium sanguineum Bloody Cranesbill (Bloody Purple) Water: M Flatted - Plugs @6" On Center Zoysia tenuifolia Korean Grass Water: M X - 5 Gallon Pennisetum x advena 'Rubrum' Red Fountain Grass Water: L X - 5 Gallon Sollya heterophylla Australian Bluebell Creeper Water: M/L X - 5 Gallon Gaura lindheimeri Gaura, Whirling Butterflies, White Gaura, Butterfly Gaura Water: M/L X - 5 Gallon Viburnum tinus 'Spring Bouquet' Spring Boquet Laurustinus Water: M/L X - 5 Gallon Santolina rosemarinifolia Green Santolina Water: M/L Flatted - Plugs @18" On Center Myoporum parvifolium 'Pink' Pink Australian Racer Water: M X - 5 Gallon Distictis buccinatoria Blood-red Trumpet Vine Water: M X - 15 Gallon Water: M Podocarpus macrophylla Yew Pine Quercus agrifolia Coast Live Oak Quercus suber Cork Oak Quantity - Size Botanical Name Comon Name X - 36" Box Lagerstroemia indica 'Natchez' White Hybrid Crape Myrtle Quantity - Size Botanical Name Comon Name X - 36" Box Pinus canariensis Canary Island Pine Quantity - Size Botanical Name Comon Name X - 36" Box Quantity - Size Botanical Name Comon Name X - 36" Box Water: M - Single Tunk Notes Water: M/L - Standard Notes Water: M/L - Single Trunk Notes Water: M/L - Standard Notes Arbutus 'Marina' Quantity - Size Botanical Name Comon Name X - 36" Box Water: M/L - Single Trunk NotesPlant Palette Trees Symbol Marina Strawberry Tree 15-13 Land DD2015_10130-dwg 4 5 K L 3 1 6 7 13 22 21 18 17 14 23 GF H E 15 J PROTECTED TREETO REMAIN CORNELL DRIVE WINDSOR ROAD COLORADO BOULEVARD SANTA ANITA AVENUE A PROTECTED TREESTO REMAIN M PROTECTED TREETO REMAIN Javier GonzalezNo. Cxxxxx Exp. x-xx-17 Robert G. TylerNo. C18812 Exp. 8-31-17 Date Reviewed Drawn ByDescription Do not scale drawings. Contractor shall verifyand be responsible for all dimensions andconditions on the site and Tyler Gonzalez Architects, Inc. shall be notified immediately ofany variations from the dimensions and conditions indicated on these drawings. Drawings, specifications, and other documents,including those in electronic form, prepared by the Architect and the Architect's consultants areInstruments of Service for use solely with respect to this Project. The Architect and theArchitect's consultants shall be deemed theauthors and owners of their respective Instruments of Service and shall retain all common law, statutory and other reserved rights, including copyrights. Visual contact withthese documents constitute prima faciaacceptance of these conditions.Architect of RecordIssue Dates Use of Architect's Drawings2015 Tyler Gonzalez Architects, Inc. c Sheet No.Project No.Scale 139 South Hudson Ave., Suite 300Pasadena, CA 91101626.396.9599 www.TGArchitects.net 1/16" = 1'-0" L-1.0 Checker Author 2015-09-3015-13PLANTING PLAN501 N. Santa Anita Ave. Arcadia, CA 91006 SANTA ANITA CONDOMINIUMS 1/16" = 1'-0" 1 Landscape Plan - Site N No.DescriptionDate AB CDF E KEY PLAN Colorado Blvd. Santa Anita Blvd. -DYLHU*RQ]DOH]1R&[[[[[ ([S[[[ 5REHUW*7\OHU1R& ([S 'DWH 5HYLHZHG 'UDZQ%\'HVFULSWLRQ Do not scale drawings. Contractor shall verifyand be responsible for all dimensions andconditions on the site and Tyler Gonzalez Architects, Inc. shall be notified immediately ofany variations from the dimensions and conditions indicated on these drawings. Drawings, specifications, and other documents,including those in electronic form, prepared by the Architect and the Architect's consultants areInstruments of Service for use solely with respect to this Project. The Architect and theArchitect's consultants shall be deemed theauthors and owners of their respective Instruments of Service and shall retain all common law, statutory and other reserved rights, including copyrights. Visual contact withthese documents constitute prima faciaacceptance of these conditions.Architect of RecordIssue Dates Use of Architect's Drawings7\OHU*RQ]DOH]$UFKLWHFWV,QF c Sheet No.Project No.Scale 6RXWK+XGVRQ$YH6XLWH3DVDGHQD&$ ZZZ7*$UFKLWHFWVQHW 1" = 200'-0" A-0.1 Checker Author 2015-09-3015-13CONTEXT ELEVATIONS501 N. Santa Anita Ave. Arcadia, CA 91006 SANTA ANITA CONDOMINIUMS No.DescriptionDate1/8" = 1'-0" 3. North/South Context Elevation along Windsor Road 2. North/South Context Elevation along Santa Anita Avenue1B. East/West Context Elevation along Colorado Blvd.1A. East/West Context Elevation along Colorado Blvd. Colorado Blvd. Newman Ave. Newman Ave. Colorado Blvd. Santa Anita Avenue Gold Line Railway MATCHLINE MATCHLINE 1A 1B 2 3 Plans gathered via Google Maps aligned to a 1/8" = 1'-0" scaledsite. Elevations gathered via images from Google Street View andaligned to scaled Google Maps. Typical heights (doors, windows,floor-to-floor heights) were used to doublecheck heights of contextelevations. Context Information: TYLER GONZALEZ ARCHITECTS, INC. 501 NORTH SANTA ANITA AVENUEVIEW FROM SANTA ANITA AVE. LOOKING WEST TYLER GONZALEZ ARCHITECTS, INC. 501 NORTH SANTA ANITA AVENUE VIEW FROM SANTA ANITA AVE. & COLORADO BLVD. LOOKING NORTHWEST TYLER GONZALEZ ARCHITECTS, INC. 501 NORTH SANTA ANITA AVENUEVIEW FROM COLORADO BLVD. LOOKING NORTHEAST TYLER GONZALEZ ARCHITECTS, INC. 501 NORTH SANTA ANITA AVENUEVIEW FROM CORNELL DRIVE LOOKING EAST TYLER GONZALEZ ARCHITECTS, INC. 501 NORTH SANTA ANITA AVENUEVIEW FROM WINDSOR ROAD LOOKING EAST Attachment No. 5 Attachment No. 5 Extension Requests Attachment No. 6 Attachment No. 6 Oak Tree Report and Addenda 1 Jordan Chamberlin From:Christy Cuba <christy@cycarlberg.com> Sent:Thursday, August 20, 2015 9:09 AM To:F8GI Yahoo; Jordan Chamberlin Subject:RE: Addendum to Arborist Report, latest COA from Engineer/PW Dear Ms. Chamberlin, This email is a follow-up to our phone call of this morning. I have reviewed the updated site plans with regard to the encroachments on two oak trees and one ash tree in the northeast sections of the property at 501 Santa Anita Avenue. The encroachments do not appear to have changed significantly from the original plans addressed in our protected tree report of March 19, 2014. In my opinion, no new recommendations are necessary. Please feel welcome to contact me with any questions. Thank you. Christy Cuba Carlberg Associates 626.428.5072 www.cycarlberg.com Sent from my Android ----- Forwarded Message ----- From: Jordan Chamberlin <jchamberlin@ci.arcadia.ca.us> To: 'Scott Yang' <f8giscott@yahoo.com> Cc: Kenneth Pang <kpang@cda-arc.com> Sent: Tuesday, August 18, 2015 7:45 AM Subject: RE: Addendum to Arborist Report, latest COA from Engineer/PW Scott, I have the latest from Engineering and I am waiting on PW to finalize theirs. Regarding the letter from the Arborist, it doesn’t appear that much has changed adjacent to the tree that is to be encroached upon but it would be helpful if she addressed that as well. It could be as simple as a line or two on that, that way both the Oak Tree Removal and Oak Tree Encroachment are up to date. The additional trees she recommends and their location seem good. The landscape architect can update accordingly. Thanks. __________________________________ Jordan Chamberlin Assistant Planner|City of Arcadia 626-821-4334| JChamberlin@ArcadiaCA.gov From: Scott Yang [mailto:f8giscott@yahoo.com] Sent: Monday, August 17, 2015 11:29 PM To: Jordan Chamberlin Cc: Kenneth Pang Subject: Fw: Addendum to Arborist Report, latest COA from Engineer/PW Attachment No. 7 Attachment No. 7 Initial Study dated September 23, 2015 SANTA ANITA RESIDENCE PROJECT CITY OF ARCADIA 501 N. SANTA ANITA AVENUE, ARCADIA, CA INITIAL STUDY Tentative Tract Map No. 14-03 (73106) Zone Variance No. ZV 15-02 Modification No. MP 14-17 Oak Tree Encroachment Permit No. TRE 14-30 Architectural Design Review MFADR 14-09 September 23, 2015 Lead Agency: City of Arcadia 240 West Huntington Drive Arcadia, CA 91006 Prepared by: LSA Associates, Inc. 1500 Iowa Avenue, Suite 200 Riverside, CA 92507 SANTA ANITA RESIDENCE PROJECT INITIAL STUDY LSA SAA1401 ii SANTA ANITA RESIDENCE PROJECT CONTENTS INITIAL STUDY SECTION 1 BACKGROUND ................................................................................... 1 1.1 SUMMARY .................................................................................................. 1 1.2 INTRODUCTION ......................................................................................... 1 SECTION 2 PROJECT DESCRIPTION...................................................................... 2 2.1 PROJECT BACKGROUND .............................................................................. 2 2.2 EXISTING UTILITY INFRASTRUCTURE .......................................................... 2 2.3 EASEMENTS AND DEDICATIONS .................................................................. 7 2.4 PROJECT CHARACTERISTICS ....................................................................... 7 2.5 REGULATORY REQUIREMENTS, PERMITS, AND APPROVALS ........................ 12 SECTION 3 ENVIRONMENTAL DETERMINATION .................................................. 14 3.1 ENVIRONMENTAL FACTORS POTENTIALLY AFFECTED ................................. 14 3.2 DETERMINATION...................................................................................... 14 SECTION 4 ENVIRONMENTAL CHECKLIST AND DISCUSSION ................................ 15 I. AESTHETICS ............................................................................................ 15 II. AGRICULTURE RESOURCES ....................................................................... 16 III. AIR QUALITY ............................................................................................ 17 IV. BIOLOGICAL RESOURCES .......................................................................... 18 V. CULTURAL RESOURCES ............................................................................. 19 VI. GEOLOGY AND SOILS ............................................................................... 21 VII. GREENHOUSE GAS EMISSIONS .................................................................. 22 VIII. HAZARDS AND HAZARDOUS MATERIALS .................................................... 23 IX. HYDROLOGY AND WATER QUALITY ........................................................... 25 X. LAND USE AND PLANNING ........................................................................ 27 XI. MINERAL RESOURCES ............................................................................... 29 XII. NOISE ..................................................................................................... 29 XIII. POPULATION AND HOUSING ..................................................................... 31 XIV. PUBLIC SERVICES ..................................................................................... 32 XV. RECREATION ............................................................................................ 32 XVI. TRANSPORTATION/TRAFFIC ...................................................................... 33 XVII. UTILITIES AND SERVICE SYSTEMS ............................................................ 35 XVIII. MANDATORY FINDINGS OF SIGNIFICANCE ................................................. 38 SECTION 5 LIST OF PREPARERS ........................................................................ 40 5.1 LSA ASSOCIATES, INC. ............................................................................. 40 5.2 CITY OF ARCADIA .................................................................................... 40 SECTION 6 REFERENCES ................................................................................... 41 SANTA ANITA RESIDENCE PROJECT INITIAL STUDY LSA SAA1401 iii APPENDICES A Air Quality/Greenhouse Gas Information B Tree Report C Historical Information D Train Noise Assessment LIST OF FIGURES Figure 1: Regional Location ...................................................................................... 3 Figure 2: Project Site ............................................................................................... 4 Figure 3: Site Photographs ....................................................................................... 5 Figure 4a: Existing Easements and Dedications .......................................................... 8 Figure 4b: Proposed Easements and Dedications ........................................................ 9 Figure 5: Project Site Plan ...................................................................................... 10 Figure 6: Example Elevations .................................................................................. 11 SANTA ANITA RESIDENCE PROJECT INITIAL STUDY LSA SAA1401 1 SECTION 1 BACKGROUND 1.1 SUMMARY Project Title: Santa Anita Residence Project Lead Agency Name and Address: City of Arcadia 240 West Huntington Drive Arcadia, CA 91006 Contact Person and Phone Number: Jordan Chamberlin, Assistant Planner, or Lisa Flores, Planning Services Manager (626) 574-5445 Project Location: 501 North Santa Anita Avenue Project Sponsor’s Name and Address: Arcadia Santa Anita LLC, 9674 Telstar Avenue #C El Monte, CA 91731 General Plan Designation: High Density Residential (HDR) (12-30 dwelling units per acre) Zoning Designation: High Density Multiple Family Residential (R-3) 1.2 INTRODUCTION The City of Arcadia incorporated in 1904 and has contributed to the rich history of Southern California for over 100 years, and the City is home to the famous Santa Anita Park horse racing track. A church was constructed on the project site in 1953. The property changed ownership over the years and was most recently operated as the Mandarin Baptist Church of Pasadena, but is presently vacant. The site contains one church building and associated parking areas to the east and west. Access is via Windsor Road off of Santa Anita Ave. There is currently no direct access to Colorado Boulevard or Santa Anita Avenue. The applicant is proposing to develop 20 multi-family residences on the 1.05-acre site which is consistent with the existing High Density Residential (HDR) land use designation and the R-3 Multi-Family Residential zoning but does not meet the minimum density requirement. Adjacent uses include multi-family residential buildings to the north, retail commercial uses and a car wash (Fasching’s Car wash) along Santa Anita Avenue and Colorado Boulevard to the south, multi-family and a gas station (Chervron), commercial office and a drive through restaurant (In-N-Out) to the east, the Foothill Gold Line rail line to the west runs along the rear property line of the subject site, and Newcastle Park is just west of the railroad tracks. SANTA ANITA RESIDENCE PROJECT INITIAL STUDY LSA SAA1401 2 SECTION 2 PROJECT DESCRIPTION 2.1 PROJECT BACKGROUND Location and Existing Site Conditions. As shown in Figures 1 through 3, the Project site is located at 501 North Santa Anita, and is identified by Assessor Parcel Number APN 5775-027-027 and Lot 15 of Tract No. 17329. Currently, the site is developed with a church building, which was constructed in 1953 but is no longer in use. The former church covers an area of 12,047 square feet. The rest of the site is primarily paved surface parking, with landscaping and one oak tree. The site is bound by multi-family residential housing and Cornell Drive to the north, North Santa Anita Avenue to the east, West Colorado Boulevard to the south, and Windsor Road and the Atchison Topeka and Santa Fe (AT&SF) railroad line (Foothill Gold Line) to the west. Vehicular access for the proposed project is at the intersection of Cornell Drive and Windsor Road, and further west on Cornell Drive. Surrounding uses include multi-family residential housing to the north, commercial uses, gas station and multi-family residential to the east, commercial uses and a car wash to the south, and a public park (Newcastle Park) to the west. 2.2 EXISTING UTILITY INFRASTRUCTURE Offsite water from the neighboring property to the north passes through the site through a 15’ surface drainage easement along a portion of the north property line before being collected by a catch basin on the site. The catch basin captures the offsite and onsite water and transfers the water into a 22” × 36” storm drain located in an easement that runs through the property to Santa Anita along Colorado Blvd, with an overflow for water to run down to Colorado Blvd to be captured by a separate storm drain. The storm drains tie into the LA County storm drain system on Santa Anita Avenue. Storm drainage in the City is provided by curbs and gutters along streets, which direct water into the catch basins, pipes, and washes that run in a southerly direction in or near the City. Our four miles of City-maintained storm water management facilities are present in Arcadia, which connect to regional flood-control and runoff conveyance facilities. Storm water flows in a southerly direction through the Eaton Wash, Arcadia Wash, Santa Anita Wash, Sierra Madre Wash, and Sawpit Wash toward the Rio Hondo, which runs southwest into Whittier Narrows and continues southwest to join the Los Angeles River in Downey. Water is provided to the Project site through a 12-inch pipeline located in Windsor Road and Cornell Drive. The City of Arcadia provides potable water to City residents and obtains water primarily from local groundwater supplies and treated imported water from the Metropolitan Water District of Southern California (MWD). The City does not typically use service from MWD because the City’s collective groundwater supplies are generally sufficient to meet the City’s water demands. Sewage from the Project site is conveyed through an eight-inch pipeline located in Cornell Dr., passing through the property in an easement along the south property line to the sewer main on Santa Anita Ave. Local sewer lines are maintained by the City and convey wastewater into trunk lines that are maintained by the Sanitation Districts of Los Angeles County. FIGURE 1 Arcadia Multi-Family ResidentialInitial Study Regional and Project Location 01,0002,000 Feet S!!N I:\SAA1401\Reports\IS\fig1_RegLoc.mxd (12/10/2014) SOURCE: Bing Aerial, 2010 Aä ?l!"^$ %&o( !"`$ ?q A» %&l( A» !"a$ !"`$ %&l( !"^$ KË %&g( %&g( AË A¥ !"a$ !"a$ !"`$KË Pacific Ocean Los Angeles County Orange County SanBernardinoCounty RiversideCounty Regional Location Project Area 01020 Miles S!!N Project Location SANTA ANITA AVENUE COLORADO BOULEVARD Metro Railroad NEWMAN AVENUE WINDSOR ROADCORNELL DRIVE §¨¦210 Newcastle Park Residential Residential Residential Angeles National Forest Headquarters Retail Commercial CommercialResidential Commercial Commercial FIGURE 2 Arcadia Multi-Family ResidentialInitial Study Project Site 0100200 Feet S!!N I:\SAA1401\Reports\IS\fig2_Project.mxd (12/10/2014) SOURCE: Google Earth, 2014. Project Boundary SANTA ANITA RESIDENCE PROJECT INITIAL STUDY LSA SAA1401 5 Figure 3: Site Photographs A. Looking northwest toward site at intersection of Colorado Blvd./Santa Anita Ave. B. Looking northwest across Colorado Blvd. toward project site SANTA ANITA RESIDENCE PROJECT INITIAL STUDY LSA SAA1401 6 Figure 3: Site Photographs C. Looking east along Cornell Dr. toward church building (site at right – parking) D. Looking east across western parking lot of former church site SANTA ANITA RESIDENCE PROJECT INITIAL STUDY LSA SAA1401 7 2.3 EASEMENTS AND DEDICATIONS As shown on Figure 4, Existing and Proposed Easements and Dedications, the Project involves the following easement adjustments and dedications.  A portion of existing Easement A on Lot 27 of Tract No. 17329 for storm drain purposes shall be quitclaimed by the City of Arcadia.  Existing Easement B on a portion of Lot 15 of Tract No. 17329 shall be quitclaimed by the City and grant rights to the City of Arcadia for public utility purposes, sanitary sewer, water, storm drains, electrical poles and wires, cross arms, overhead guy wires, conduits, gas main and lines, and any other utility and incidental purposes.  Easement C is located on a portion of Lot 15 of Tract No. 17329 and would grant rights for public utility purposes.  Easement D on Lot 27 and a portion of Lot 15 of would grant rights to the City of Arcadia for street and highway purposes.  Easement E on Lot 27 of Tract No. 17329 would grant rights to the City of Arcadia for storm drain purposes.  Easement F on a portion of Lot 15 of Tract No. 17329 would grants rights to the City of Arcadia for sewer and storm drain purposes.  Easement G within a portion of Lot 27 and Lot 15 of Tract no. 17329 shall be vacated to the property owner and the City of Arcadia would retain a public utility easement.  Dedication H on Lot 27 of Tract No. 17329 would grant rights to the City of Arcadia for street and highway purposes.  Easement I on a portion of Lot 15 of Tract No. 17329 would grant rights for public utility purposes and gas.  Easement J on a portion of Lot 15 of Tract No. 17329 would grant rights to the City of Arcadia for sewer purposes. 2.2 PROJECT CHARACTERISTICS The proposed “Santa Anita Residence” Project involves the construction of 20 multi- family residential units in six, two-story townhome style building on 1.18 gross acres in the City of Arcadia, which is in the County of Los Angeles. The total building area is approximately 40,438 square feet. The buildings would be Contemporary in style and are approximately 29 feet in height. The exterior of the building would include smooth white and tan stucco, cement siding, and cultured stone. Metal framed windows, shed roofs with grey multidimensional roof tile, and thoughtfully placed architectural projections and balconies further emphasize the Contemporary style. Each unit will include at least three bedrooms and two and a half bathrooms and will range from approximately 1,439 to 2,520 square feet of living area. Additionally, all units will have a private outdoor area ranging in size from 195 square feet to 852 square feet. Four units will face N. Santa Anita Avenue, seven units will face Colorado Boulevard, another four units will face Windsor Road or Cornell Drive, and the remaining units will face the SOURCE: EGL Associates, Inc, 11/10/14. I:\ArcadiaMulti-Fam\Reports\IS\fig4a_ExistEasementsDedi.ai (09/23/2015) Existing Easements and Dedications Arcadia Multi-Family Residential Initial Study FIGURE 4A SOURCE: EGL Associates, Inc, 11/10/14. I:\ArcadiaMulti-Fam\Reports\IS\fig4b_PropEasementsDedi.ai (09/23/2015) Proposed Easements and Dedications Arcadia Multi-Family Residential Initial Study FIGURE 4B 05102030 50 E PL PL PL PL PL PL PL PL PL NEW PL NEW PL NEW NEW NEW NEW NEW NEW NEW EXISTING EXISTING COLORADO BLVD SANTA ANITA AVE TRASH 1 H 123 456 7 9 10 8 SEWAGE EASEMENT 5'-0" CITY ENGINEERING EASEMENT ADJACENT BLDG. ADJACENTBLDG. ADJACENT BLDG. CORNELL DRIVE WINDSOR RD TRASH 2 10'-0" SCE POWER POLE EASEMENT SEWAGE EASEMENT LOT A LOT B LOT A LOT B LOT A LOT B AS-101.1 SANTA ANITA RESIDENCEARCADIA SANTA ANITA LLC PARTICIPANTS 501 N. SANTA ANITA AVE RESIDENTIAL NEVIS_SANTA ANITA ARCADIA, CA 91006 VICINITY MAPSCALE: N.T.S SHEET INDEX PROJECT DATA DIAGRAM 1: LOT A & BSCALE: N.T.SDIAGRAM 2: LOT GAINS AND LOSSESSCALE: N.T.SDIAGRAM 3: USEABLE VS. UNUSEABLE LANDSCALE: N.T.S SITE NOTES FIGURE5ArcadiaMulti-FamilyResidentialInitialStudy ProjectSitePlan A-200.1 SANTA ANITA RESIDENCE ARCADIA SANTA ANITA LLC SOURCE: Creative Design Associates, 2014 I:\ArcadiaMulti-Fam\Reports\IS\fig5_Elevations.ai (11/21/2014) Example Elevations Arcadia Multi-Family Residential Initial Study FIGURE 5 SANTA ANITA RESIDENCE PROJECT INITIAL STUDY LSA SAA1401 12 interior side property line. Access to the site is provided from Santa Anita Avenue, east to Newman Avenue, and then south to Windsor Road and Cornell Drive. 50 parking spaces are planned, including 12 surface parking spaces and 38 semi-subterranean parking spaces. 40 will be garage spaces for residents and 10 will be surface lot parking for guests. Figures 5 and 6 illustrate the design of the proposed project. As part of the proposed project, City staff will incorporate the following into standard or site specific conditions of approval that will assure potential environmental impacts of the project are as outlined in this evaluation:  dust and other standard air pollutant control measures;  water quality protection and erosion control measures;  incorporate tree protection actions identified in Carlberg Associates report;  design actions to address local geotechnical and soil constraints; and  greenhouse gas emission reduction strategies for residential uses. 2.3 REGULATORY REQUIREMENTS, PERMITS, AND APPROVALS The project applicant has applied for or will need the following discretionary approvals from the City relative to this project:  Tentative Tract Map No. 14-03 (73106) – To subdivide the air space for 20 condominium units (AMC Sec. 9255.2.7);  Zone Variance No. ZV 15-02 - To allow a 20-unit multiple-family development in lieu of the minimum 23-unit density requirement;  Modification No. MP 14-17 – To allow the following Zoning Modifications: o An encroachment into the 75’ special setback on Colorado Blvd; o A 15’-0”, 1st and 2nd story, front yard setback along Santa Anita Ave in lieu of the 25’-0” required (AMC Sec. 9255.2.3); o A 5’-0” encroachment into the interior side yard setback for a 5’-0” wide pedestrian access ramp adjacent to the northerly property line in lieu of the 10’-0” required (AMC Sec. 9255.2.6(B)). o A 7’-7” to 21’-9”, 1st and 2nd story, street side yard setback along Colorado Blvd in lieu of the 25’-0” required (AMC Sec. 9255.2.4); o An 7’-7” street side yard setback and 9’-0” front yard setback for an open stairwell adjacent to Colorado Blvd in lieu of 25’-0” required (AMC Sec. 9255.2.6(B)); o To allow three required parking spaces to be located within the 25’-0” street side yard setback for units 1, 2, and 11 (AMC Sec. 9255.2.9); o To allow three air conditioning units to be located in the required street side yard setback for units 2, 3, and 11 (AMC Sec. 9255.2.18); o To allow a building, Building F, to be 219’-0” in length in lieu of the 165’- 0” maximum (AMC Sec. 9255.2.13); and SANTA ANITA RESIDENCE PROJECT INITIAL STUDY LSA SAA1401 13 o To allow 85 linear feet of fencing adjacent to the northerly interior side property line and 80 linear feet of fencing adjacent to the southerly street side yard property line to exceed 6’-0” in height with a maximum height of 11’-6” measured from the lowest adjacent grade (AMC Sec. 9255.2.21.2).  Oak Tree Encroachment Permit No. TRE 14-30 – To allow construction within the protected area of one, Coast Live Oak tree; and  Architectural Design Review No. ADR 14-09 – To approve the proposed 20-unit multiple-family development. Other non-discretionary actions anticipated to be taken by the City at the Staff level as part of the proposed project include:  Approval of a Storm Water Pollution Prevention Plan (SWPPP) to mitigate site runoff during construction (i.e., over the short-term) and a Standard Urban Stormwater Management Plan (SUSMP) to mitigate for post-construction runoff flows (i.e., over the long-term during project occupancy and operation).  Building permit. The comprehensive building permit includes building permit, plumbing, mechanical, and electrical permits.  Grading permit.  Sewer connection permit.  Encroachment permit for work within the City’s right-of-way. Development of the proposed project may require the following permits and/or approvals from other responsible agencies:  A National Pollutant Discharge Elimination System (NPDES) permit from the Regional Water Quality Control Board - Los Angeles Region to ensure that construction site drainage velocities are equal to or less than the pre-construction conditions and downstream water quality is not harmed. SANTA ANITA RESIDENCE PROJECT INITIAL STUDY LSA SAA1401 14 SECTION 3 ENVIRONMENTAL DETERMINATION 3.1 ENVIRONMENTAL FACTORS POTENTIALLY AFFECTED The environmental factors checked below would be potentially affected by this project, involving no impacts that are a “Potentially Significant Impact” or Less than Significant with Mitigation Incorporated” as indicated by the checklist on the following pages. Aesthetics Greenhouse Gas Emissions Population and Housing Agriculture Resources Hazards/Hazardous Materials Public Services Air Quality Hydrology/Water Quality Recreation Biological Resources Land Use and Planning Transportation/Circulation Cultural Resources Mineral Resources Utilities and Service Systems Geology and Soils Noise Mandatory Findings of Significance 3.2 DETERMINATION On the basis of this initial evaluation: I find that the Project COULD NOT have a significant effect on the environment, and a CATEGORICAL EXEMPTION (Class 32 – Infill Development) will be prepared. I find that the Project COULD NOT have a significant effect on the environment, and a NEGATIVE DECLARATION will be prepared. I find that although the Project could have a significant effect on the environment, there will not be a significant effect in this case because revisions in the project have been made by or agreed to by the project proponent. A MITIGATED NEGATIVE DECLARATION will be prepared. I find that the Project MAY have a significant effect on the environment, and an ENVIRONMENTAL IMPACT REPORT is required. I find that the Project MAY have a “potentially significant impact” or “potentially significant unless mitigated” impact on the environment but at least one effect 1) has been adequately analyzed in an earlier document pursuant to applicable legal standards, and 2) has been addressed by mitigation measures based on the earlier analysis as described on attached sheets. An ENVIRONMENTAL IMPACT REPORT is required, but it must analyze only the effects that remain to be addressed. Signature Date City of Arcadia Printed Name Agency SANTA ANITA RESIDENCE PROJECT INITIAL STUDY LSA SAA1401 15 SECTION 4 ENVIRONMENTAL CHECKLIST AND DISCUSSION I. AESTHETICS Would the project: Potentially Significant Impact Less than Significant with Mitigation Incorporated Less than Significant Impact No Impact a) Have a substantial adverse effect on a scenic vista? b) Substantially damage scenic resources, including, but not limited to, trees, rock outcroppings, and historic buildings within a state scenic highway? c) Substantially degrade the existing visual character or quality of the site and its surroundings? d) Create a new source of substantial light or glare, which would adversely affect daytime or nighttime views in the area? I.a - d) Less Than Significant. The most prominent scenic resources that can be viewed from the project area are the San Gabriel Mountains to the north. There are no other unique vistas, natural or undisturbed areas, or officially recognized scenic areas in the surrounding area. The project site contains an existing church and parking lot, and the surrounding area contains newer retail commercial structures to the east and south, and older multi-family residential structures to the north along Newman Avenue and Windsor Road. The proposed project would introduce six (6) multi-story multi-family residential buildings onto the site consistent with the City’s Zoning Code requirements for height but requests reduced front and street side yard setbacks due to the unusual shape and location of the property. The previous Figures 5 and 6 provide the proposed project site plan and planned elevations of the new buildings. Adjacent residential uses are north of the site, with commercial uses to the east and south (across Colorado Boulevard.) and a recreation facility (Newcastle Park) adjacent to the west across the railroad tracks. Placement of the new multi-family buildings will therefore not block any views to the north from existing residences in the area, so there will be no significant impacts regarding scenic vistas, scenic resources, or the visual quality of the area. The new buildings will also fit into the overall visual character of the area (newer commercial and older residential) as shown in Figure 3 (Site Photographs) and Figure 6. The project will also add nightlighting and a minimal amount of glare from new windows and driveway lighting fixtures. These improvements will be consistent with the City’s residential development standards (e.g., lighting) so there will be no significant impacts. SANTA ANITA RESIDENCE PROJECT INITIAL STUDY LSA SAA1401 16 II. AGRICULTURE RESOURCES Would the project: Potentially Significant Impact Less than Significant with Mitigation Incorporated Less than Significant Impact No Impact a) Convert Prime Farmland, Unique Farmland, or Farmland of Statewide Importance (Farmland), as shown on the maps prepared pursuant to the Farmland Mapping and Monitoring Program of the California Resources Agency, to non-agricultural use? b) Conflict with existing zoning for agricultural use, or a Williamson Act contract? c) Conflict with existing zoning for, or cause rezoning of , forest land (as defined in Public Resources Code section 12220(g)), timberland (as defined by Public Resources Code section 4526, or timberland zoned Timberland Production (as defined by Government Code section 51104 (g))? d) Result in the loss of forest land or conversion of forest land to non-forest use? e) Involve other changes in the existing environment which, due to their location or nature, could result in conversion of Farmland, to non-agricultural use or conversion of forest land to non-forest use? II.a - e) No Impact. The site is in a completely urban setting and contains at most a half dozen landscaped trees. It is and has been completely covered over by impervious man-made surfaces for many years. According to the Farmland Mapping and Monitoring Program (FMMP) maps, the project site is designated as “Urban Land” and is not underlain by any Prime Farmland, Unique Farmland, or Farmland of Statewide Importance, so there will be no significant impacts relative to farmland or forestland. The site and surrounding areas are zoned for urban uses so there are also no significant impacts regarding land use designations. SANTA ANITA RESIDENCE PROJECT INITIAL STUDY LSA SAA1401 17 III. AIR QUALITY Where available, the significance criteria established by the applicable air quality management or air pollution control district may be relied upon to make the following determinations. Would the project: Potentially Significant Impact Less than Significant with Mitigation Incorporated Less than Significant Impact No Impact a) Conflict with or obstruct implementation of the applicable air quality plan? b) Violate any air quality standard or contribute substantially to an existing or projected air quality violation? c) Result in a cumulatively considerable net increase of any criteria pollutant for which the project region is non-attainment under an applicable federal or state ambient air quality standard (including releasing emissions which exceed quantitative thresholds for ozone precursors)? d) Expose sensitive receptors to substantial pollutant concentrations? e) Create objectionable odors affecting a substantial number of people? III.a - e) Less than Significant Impact. LSA Associates, Inc. (LSA) compared the development characteristics of the project (20 units on 1 acre) against the South Coast Air Quality Management District’s (SCAQMD) daily construction and operational emission standards and found the project to be substantially below any of the daily thresholds. For example, the maximum daily construction emissions would be 30 pounds of NOx and 22 pounds of CO, compared to the SCAQMD thresholds of 100 and 550 pounds per day, respectively. Similarly, the maximum daily operational emissions would be 1.9 pounds of NOx and 7.8 pounds of CO, compared to the SCAQMD thresholds of 55 and 550 pounds, respectively (see Appendix A). Therefore, the project will not violate any air quality standard or expose sensitive receptors to substantial pollutant concentrations. Due to the size and nature of the project, there is no potential for the project to result in a significant impact regarding either short- or long-term air pollutant emissions. The project is consistent with zoning and land use designations for the site and surrounding area, as outlined in the City’s zoning map and General Plan Land Use Element. Therefore, the project is consistent with the Air Quality Management Plan (AQMP) for the South Coast Air Basin (Basin) managed by the SCAQMD which sets forth comprehensive programs that will eventually lead the Basin into compliance with all federal and state air quality standards. The City will assure that project construction complies with all standard City Conditions Of Approvals (COAs) relative to air quality (e.g., dust control, watering during grading, emission control equipment on work vehicles, etc.). SANTA ANITA RESIDENCE PROJECT INITIAL STUDY LSA SAA1401 18 In addition, it is a residential project in a residential area, so there will be no significant impacts regarding odors. Therefore, the project will not result in any significant air quality impacts. IV. BIOLOGICAL RESOURCES Would the project: Potentially Significant Impact Less than Significant with Mitigation Incorporated Less than Significant Impact No Impact a) Have a substantial adverse effect, either directly or through habitat modifications, on any species identified as a candidate, sensitive, or special status species in local or regional plans, policies, or regulations, or by the California Department of Fish and Wildlife or U.S. Fish and Wildlife Service? b) Have a substantial adverse effect on any riparian habitat or other sensitive natural community identified in local or regional plans, policies, regulations, or by the California Department of Fish and Wildlife or U.S. Fish and Wildlife Service? c) Have a substantial adverse effect on federally protected wetlands as defined by Section 404 of the Clean Water Act (including, but not limited to, marsh, vernal pool, coastal, etc.) through direct removal, filling, hydrological interruption, or other means? d) Interfere substantially with the movement of any native resident or migratory fish or wildlife species or with established native resident or migratory wildlife corridors, or impede the use of native wildlife nursery sites? e) Conflict with the provisions of an adopted Habitat Conservation Plan, Natural Community Conservation Plan, or other approved local, regional, or state habitat conservation plan? f) Have a substantial adverse effect, either directly or through habitat modifications, on any species identified as a candidate, sensitive, or special status species in local or regional plans, policies, or regulations, or by the California Department of Fish and Game or U.S. Fish and Wildlife Service? SANTA ANITA RESIDENCE PROJECT INITIAL STUDY LSA SAA1401 19 IV.a - f) No Impact. The proposed project site is located on a small urban infill site (approx. 1 acre) that contains no native vegetation or drainage features, and supports only limited wildlife species, mainly those that are tolerant of regular human activity including ground squirrels, rodents, and song birds such as chickadees and mockingbirds. The existing landscaping on the site includes a number of small planters with landscaped bushes and approximately a dozen trees. There is one (1) oak tree that is considered protected under the City’s Oak and Sycamore tree preservation ordinance. The oak tree has been evaluated by a Certified Arborist, Carlberg Associates – refer to the report entitled “Protected Tree Evaluation” prepared by Carlberg Associates dated March 19, 2014 and an Addendum dated August 20, 2015 (see Appendix B). One Coast Live Oak tree that is in poor health due to being topped and then cut to no more than a 6’-0” high stump by an unknown party in March 2014 will also be removed. Two (2) 36” box Coast Live Oak trees are to be planted adjacent to Cornell Drive as replacement trees which is consistent with the City’s tree preservation ordinance. City staff will include the requirements of the Carlberg Associates report in the Conditions of Approval (COAs) for the project (see Appendix B). At the time of site survey by LSA staff, there was no evidence of birds nesting in the trees or other onsite vegetation. It should be noted that migratory and raptorial birds are covered by the Migratory Bird Treaty Act, but no impacts to covered species are expected from project construction. The project site is not covered by any adopted Habitat Conservation Plan, Natural Community Conservation Plan, or other local, regional, or state habitat conservation plan. Due to the size and location of the project site, development of the proposed project will not have any significant impacts on biological resources. V. CULTURAL RESOURCES Would the project: Potentially Significant Impact Less than Significant with Mitigation Incorporated Less than Significant Impact No Impact a) Cause a substantial adverse change in the significance of a historical resource as defined in §15064.5? b) Cause a substantial adverse change in the significance of an archaeological resource pursuant to §15064.5? c) Directly or indirectly destroy a unique paleontological resource or site or unique geologic feature? d) Disturb any human remains, including those interred outside of formal cemeteries? V.a) Less than Significant Impact. CEQA Section 15064.5, Determining the Significance of Impacts to Archaeological and Historical Resources, states that: SANTA ANITA RESIDENCE PROJECT INITIAL STUDY LSA SAA1401 20 “Generally, a resource shall be considered by the lead agency to be ‘historically significant’ if the resource meets the criteria for listing on the California Register of Historical Resources (Pub. Res. Code §5024.1, Title 14 CCR, Section 4852) including the following: (A) Is associated with events that have made a significant contribution to the broad patterns of California’s history and cultural heritage; (B) Is associated with the lives of persons important in our past; (C) Embodies the distinctive characteristics of a type, period, region, or method of construction, or represents the work of an important creative individual, or possesses high artistic values; or (D) Has yielded, or may be likely to yield, information important in prehistory or history.” For buildings and other structures at least 50 years old, the completeness and integrity of the structural architecture may cause the site to pass Criterion A, B, and/or C thresholds. The threshold should be associated with the site context or theme. If sets of unusual artifacts, buried but unusual buildings, or human remains are detected during tests of cultural resources in the project site, or if a historical review of the resource finds that it was once associated with a person and/or event of historical significance at the State/National level, such resources will likely be considered potentially significant for California Register/National Register listing. The former church on the site was originally built around 1953 (61 years ago). It changed ownership and was remodeled several times over the years, and was most recently operated as the Mandarin Baptist Church of Pasadena. The State Office of Historic Preservation recommends all structures over 50 years of age be surveyed for historical significance prior to demolition. In June 2014 LSA Associates, Inc. conducted an historical assessment of the church, which is a reconnaissance-level architectural survey required as part of the demolition compliance process. The DPR 523A form completed as part of that survey indicated the church facility did not appear to be “architecturally significant” in reference to historical character (see Appendix C). It also does not appear to meet any of the four criteria previously outlined from Public Resources Code §5024.1. Based on available evidence, the former church does not appear to meet the CEQA criteria for an identified historic resource, so there is no significant impact on any identified historical resources. V.b–d) No Impact. The site has been graded and developed for many years, so it is underlain by shallow consolidated fill material, and there is no evidence the site or surrounding area is underlain by important geologic or paleontological resources, nor is there evidence the site contains any human remains. Based on available information, development of the proposed project will have no impacts on archaeological, geologic, or paleontological resources. In the event of an accidental discovery or recognition of any human remains, California State Health and Safety Code § 7050.5 dictates that no further disturbance shall occur until the County Coroner has made the necessary findings as to origin and disposition pursuant to CEQA regulations and PRC § 5097.98. If human remains are found, the LA County Coroner’s office shall be contacted to determine if the remains are recent or of Native American significance. Supporting documentation for this conclusion is included in Appendix C. SANTA ANITA RESIDENCE PROJECT INITIAL STUDY LSA SAA1401 21 VI. GEOLOGY AND SOILS Would the project: Potentially Significant Impact Less than Significant with Mitigation Incorporated Less than Significant Impact No Impact a) Expose people or structures to potential substantial adverse effects, including the risk of loss, injury, or death involving: i) Rupture of a known earthquake fault, as delineated on the most recent Alquist- Priolo Earthquake Fault Zoning Map issued by the State Geologist for the area or based on other substantial evidence of a known fault? Refer to Division of Mines and Geology Special Publication 42. ii) Strong seismic groundshaking? iii) Seismic-related ground failure, including liquefaction? iv) Landslides? b) Result in substantial soil erosion or the loss of topsoil? c) Be located on a geologic unit or soil that is unstable, or that would become unstable as a result of the project, and potentially result in on-site or off-site landslide, lateral spreading, subsidence, liquefaction or collapse? d) Be located on expansive soil, as defined in Table 18-1-B of the Uniform Building Code (1994), creating substantial risks to life or property? e) Have soils incapable of adequately supporting the use of septic tanks or alternative wastewater disposal systems where sewers are not available for the disposal of waste water? VI.a.i-iii) Less than Significant Impact. The City’s General Plan and other regional information indicates the Raymond Hill Fault Zone and the Sierra Madre Fault Zone are the only major faults located in the City of Arcadia, and there are no regional or local faults on or in the immediate vicinity of the project site. The project study area is underlined by extremely thick alluvial deposits that are subject to differential settlement during any intense shaking associated with seismic events, which can be expected for any location in Southern California. This can result in damage to property when an area settles to different degrees over a relatively short SANTA ANITA RESIDENCE PROJECT INITIAL STUDY LSA SAA1401 22 distance. Almost the entire region is subject to this hazard, but building design standards do significantly reduce the potential for harm. The site is also not located in an area subject to liquefaction. Therefore, the project site is not expected to be subject to any significant impacts regarding fault zones, strong seismic ground shaking, ground failure, or liquefaction, or landslides. VI.a.iv – e) No Impact. The project site is also a flat site and will not be subject to either onsite or offsite landslide hazards. Similarly, the site is covered with impermeable surfaces and only 1 acre in size, so grading for the proposed project will not result in substantial erosion or loss of topsoil. Available information indicates the site is not located over a hazardous geologic unit or would be subject to severe seismic activity or related impacts such as lateral spreading. Subsidence is the sudden sinking or gradual downward settling of the earth’s surface with little or no horizontal movement. Subsidence is caused by a variety of activities, which includes, but is not limited to, withdrawal of groundwater, pumping of oil and gas from underground, the collapse of underground mines, liquefaction, and hydrocompaction. However, the City of Arcadia is located on an alluvial plain that is relatively flat and expected to be stable, and groundwater levels below the site are greater than 50 feet in depth. According to the Natural Resources Conservation Service (formerly the U.S. Soil Conservation Service), the proposed project site and surrounding area are underlain by deep well-drained alluvial soils that have low to moderate expansion potential. The proposed project would be connected to the existing sewer system, so no septic or alternative wastewater disposal systems are needed. For the reasons outlined above, the project will have no significant impacts related to landslides, erosion, loss of topsoil, lateral spreading, liquefaction, expansive soils, or use of septic tanks or alternative treatment systems. VII. GREENHOUSE GAS EMISSIONS Would the project: Potentially Significant Impact Less than Significant with Mitigation Incorporated Less than Significant Impact No Impact a) Generate gas emissions, either directly or indirectly, that may have a significant impact on the environment? b) Conflict with an applicable plan, policy or regulation adopted for the purpose of reducing the emissions of greenhouse gases? SANTA ANITA RESIDENCE PROJECT INITIAL STUDY LSA SAA1401 23 VII.a-b) Project-related emissions of GHGs include direct emissions from project vehicular traffic and indirect emissions from electric power plants generating electricity, energy used to provide water, and the processing of solid waste. The project would utilize quantifiable amounts of electricity, natural gas, water and generate solid waste that will contribute CO2, CH4, and N2O emissions. However, based the size and type of project (20 multi-family residential units on 1 acre), LSA Associates, Inc. (LSA) concludes that greenhouse gas (GHG) emissions from the proposed project are far below the South Coast Air Quality Management District’s (SCAQMD) thresholds for GHGs (3,000 metric tons per year)(see Appendix A). The City of Arcadia has adopted policies under the City’s General Plan to reduce greenhouse gas emissions in compliance with SB 375 and AB 32, to reduce greenhouse gas emissions to 1990 levels by 2020, and 80 percent below 1990 levels by 2050. The project will be required to comply with these local GHG emission control measures as standard Conditions of Approval (COAs). Compliance with the City’s policies will result in less than significant project and cumulative impacts related to GHGs and global climate change. In addition, the project is subject to mandatory provisions of the 2010 California Green Building Code which was implemented in January 2014 to reduce GHG emissions. The code specifies a reduction in water use by using water efficient plumbing fixtures and automated irrigation systems that are weather sensitive. Energy and air pollution reduction is accomplished by using low VOC paints and carpets, installation of whole house exhaust fans, installation of gas not wood burning fireplaces, and installation of energy efficient appliances. VIII. HAZARDS AND HAZARDOUS MATERIALS Would the project: Potentially Significant Impact Less than Significant with Mitigation Incorporated Less than Significant Impact No Impact a) Create a significant hazard to the public or the environment through the routine transport, use, or disposal of hazardous materials? b) Create a significant hazard to the public or the environment through reasonably foreseeable upset and accident conditions involving the release of hazardous materials into the environment? c) Emit hazardous emissions or handle hazardous or acutely hazardous materials, substances, or waste within one-quarter mile of an existing or proposed school? SANTA ANITA RESIDENCE PROJECT INITIAL STUDY LSA SAA1401 24 Potentially Significant Impact Less than Significant with Mitigation Incorporated Less than Significant Impact No Impact d) Be located on a site which is included on a list of hazardous materials sites compiled pursuant to Government Code Section 65962.5 and, as a result, would it create a significant hazard to the public or the environment? e) For a project located within an airport land use plan or, where such a plan has not been adopted, within two miles of a public airport or public use airport, would the project result in a safety hazard for people residing or working in the project area? f) For a project within the vicinity of a private airstrip, would the project result in a safety hazard for people residing or working in the project area? g) Impair implementation of or physically interfere with an adopted emergency response plan or emergency evacuation plan? h) Expose people or structures to a significant risk of loss, injury or death involving wildland fires, including where wildlands are adjacent to urbanized areas or where residences are intermixed with wildlands? VIII.a-h) The site currently contains a former church and demolition will comply with existing federal and state laws regarding hazardous materials if any are present (e.g. asbestos- containing materials, lead-based paint, etc.). The project proposes to develop six multi-family residential buildings that are not expected to use or generate substantial or significant amounts of hazardous materials. Compliance with existing federal, state, and local laws/regulations regarding hazardous materials will ensure that potential hazard-related impacts of the project are less than significant. There is a private school, Arroyo Pacific Academy, located within a quarter mile of the project site. The main campus building is located at 41 W. Santa Clara Street and a secondary building for art technology, arts, and fitness is located at 400 Rolyn Place, approximately 1,110 feet and 500 feet south of the subject site, respectively. The proposed project, however, would not emit or produce any hazardous materials that would represent a health hazard to the public. There are no properties in the vicinity of the project site, nor is the project site itself, on any Federal Superfund Sites (NPL), State Response Sites, Voluntary Cleanup Sites, School Cleanup Sites, Permitted Sites, or Corrective Action sites lists. Neither the project site nor the surrounding properties within one-quarter mile of the site are identified on the California State Water Resources Control Board’s Geotracker list of leaking underground fuel tank (LUFT) sites. SANTA ANITA RESIDENCE PROJECT INITIAL STUDY LSA SAA1401 25 The proposed project site is not located within an airport land use plan or within two miles of a public airport or private airstrip. Therefore, there would be no airport-related safety hazards related to the project. Police, fire, and paramedic services are currently provided by the City to the project site. The site is accessible via Colorado Boulevard and Santa Anita Avenue. Development of the project will not reduce the existing level of emergency access or the ability to evacuate onsite or area residents if an emergency or disaster occurs. According to the California Department of Forestry and Fire Protection (CAL Fire) mapping system the City of Arcadia contains areas considered to be Very High Fire Hazards Zones. The map created by CAL Fire has been adopted by the City to target these areas and implement stringent wild land fire mitigation strategies. The proposed project site does not fall within any fire hazard zones, and is not within close proximity to any wildlands and will not have a fire hazard impact. Review of proposed building plans is a standard part of the City’s development review process, and the proposed project will be required to comply with any building design requirements of the City Fire Department (see Section XIV, Public Services) to address urban (non-wildland) fire hazards. In conclusion, compliance with existing federal, state, and local laws/regulations and payment of established development impact fees will help ensure that potential hazard-related impacts of the project are less than significant. IX. HYDROLOGY AND WATER QUALITY Would the project: Potentially Significant Impact Less than Significant with Mitigation Incorporated Less than Significant Impact No Impact a) Violate any water quality standards or waste discharge requirements? b) Substantially deplete groundwater supplies or interfere substantially with groundwater recharge such that there would be a net deficit in aquifer volume or a lowering of the local groundwater table level (e.g., the production rate of pre-existing nearby wells would drop to a level which would not support existing land uses or planned uses for which permits have been granted)? c) Substantially alter the existing drainage pattern of the site or area, including through the alteration of the course of a stream or river, in a manner that would result in substantial erosion or siltation on site or off site? SANTA ANITA RESIDENCE PROJECT INITIAL STUDY LSA SAA1401 26 Potentially Significant Impact Less than Significant with Mitigation Incorporated Less than Significant Impact No Impact d) Substantially alter the existing drainage pattern of the site or area, including through the alteration of the course of a stream or river, or substantially increase the rate or amount of surface runoff in a manner that would result in flooding on site or off site? e) Create or contribute runoff water, which would exceed the capacity of existing or planned storm water drainage systems or provide substantial additional sources of polluted runoff? f) Otherwise substantially degrade water quality? g) Place housing within a 100-year flood hazard area as mapped on a federal Flood Hazard Boundary or Flood Insurance Rate Map or other flood hazard delineation map? h) Place within a 100-year flood hazard area structures that would impede or redirect flood flows? j) Inundation by seiche, tsunami, or mudflow? IX.a-j) No Impact. In 1972, the Clean Water Act (CWA) was amended to require National Pollutant Discharge Elimination System (NPDES) permits for the discharge of pollutants into “Waters of the U.S.” from any point source. In 1987, the CWA was amended to require that the U.S. Environmental Protection Agency establish regulations for permitting under the NPDES permit program, that at the local level cities must ensure provision of vegetates swales, buffers, and infiltration areas in new development projects. For Arcadia, the NPDES program is issued by the Regional Water Quality Control Board, Los Angeles Region. The NPDES program coordinates the actions of all incorporated cities within this region (except Long Beach) and Los Angeles County to regulate and control storm water and urban runoff into Los Angeles County waterways and ocean. The proposed project will be subject to NPDES requirements as well as the City of Arcadia’s Water Efficient Landscape Ordinance (WELO) which is a standard regulatory requirement that is incorporated into project design through standard Conditions of Approval (COAs). During the construction period, the City would require the project to use a series of standard BMPs to reduce erosion and sedimentation. These measures may include the use of gravel bags, silt fences, hay bales, check dams, hydroseed, and soil binders. The construction contractor would be required to operate and maintain these controls throughout the duration of on-site construction activities. The site is already fully developed with impervious surfaces, and the proposed project would result in similar long-term conditions. Onsite runoff will be either infiltrated into the ground in landscaped areas or be directed to several catch basins and down drains which will then direct SANTA ANITA RESIDENCE PROJECT INITIAL STUDY LSA SAA1401 27 runoff into the City’s storm drain system. New development is required to meet or exceed pre- project conditions for stormwater discharge, and the proposed project would be required to retain any additional runoff onsite and discharge it to the storm drain system at rates that do not exceed pre-project conditions. Adherence to NPDES requirements is required of all development within the City. Due to the small size of the site, no impacts related to groundwater quality or supply are expected. Most of the annual rainfall in the region occurs in the winter with potential flooding occurring in the City from intense storms resulting in rapid runoff. The Federal Emergency Management Agency (FEMA) Flood Insurance Rate Maps (FIRMs) identify areas subject to flooding during the 100-year storm event. Note that the term “100-year” is a measure of the size of the flood, not how often it occurs. The “100-year flood” is a flooding event that has a one percent chance of occurring in any given year. Based on these FIRM maps, the project site is not located within the 100-year floodplain; therefore, the project would not impede or redirect flood flows. Construction and operation of the proposed project would not cause or increase the likelihood of failure of a levee or dam that could result in flooding. The project site is located within the flood hazard zone for Santa Anita Debris Dam, which is located along the Santa Anita Wash approximately 1.7 miles northeast of the project site. However, the project site and the entire community is in Flood Zone D which does not require the City to implement any flood plain management regulation as a condition per the National Flood Insurance Program from the Federal Emergency Management Agency. Therefore, impacts in this regard would be less than significant. The project site does not have any enclosed bodies of water (e.g., reservoir tank or pond) that could cause or result in a seiche (standing wave) during a seismic event. The site is also not located near the Pacific Ocean or within a tsunami or mudflow hazard area. Therefore, the project would not result in any significant impacts related to these hazards, and no mitigation is required. With implementation of the City’s development review process, potential short- and long-term impacts related to drainage, water quality, flooding, and dam inundation will be less than significant. X. LAND USE AND PLANNING Would the project: Potentially Significant Impact Less than Significant with Mitigation Incorporated Less than Significant Impact No Impact a) Physically divide an established community? SANTA ANITA RESIDENCE PROJECT INITIAL STUDY LSA SAA1401 28 b) Conflict with any applicable land use plan, policy, or regulation of an agency with jurisdiction over the project (including, but not limited to the general plan, specific plan, local coastal program, or zoning ordinance) adopted for the purpose of avoiding or mitigating an environmental effect? c) Conflict with any applicable habitat conservation plan or natural community conservation plan? X.a and c) No Impact. The project site is in an urbanized area and is surrounded by developed uses. It is also on the northeast corner of the intersection of two major arterials (Colorado Boulevard and Santa Anita Avenue.) with commercial uses along both roadways adjacent to the site. The only existing residential land uses are north of the site (along Newman Avenue and Windsor Road) and the rest of the surrounding land uses are commercial in nature or public facilities (park to the west). In addition, the proposed site plan indicates that access in and around the site will be maintained similar to that which exists now. Therefore, demolition of the existing former church facility and development of new multi-family residential uses on the project site would not physically divide an established community. Arcadia’s General Plan and zoning map designate the proposed project and surrounding area with the following land uses: Area/ Direction Existing Land Uses Land Use Designations Zoning Designations Project Site Church (vacant) and parking lot High Density Residential (HDR) (12-30 dwelling units per acre) High Density Multi-Family Residential (R-3) North Multi-family residential High Density Residential (HDR) (12-30 dwelling units per acre) High Density Multi-Family Residential (R-3) South Colorado Boulevard and retail commercial uses Commercial (Downtown Overlay) General Commercial (C-2) (Downtown Overlay) Commercial Manufacturing (C-M) East Santa Anita Avenue and retail commercial uses Commercial High Density Residential (HDR) (12-30 dwelling units per acre) General Commercial (C-2) High Density Multi-Family Residential (R-3) West Multi-family residential, railroad tracks and Newcastle Park (beyond tracks) High Density Residential (HDR) (12-30 dwelling units per acre), Rail Right-of-Way, and Open Space-Outdoor Recreation (park) High Density Multi-Family Residential (R-3), Rail Right-of-Way (R-R), Public Purpose (S-2) The High Density Residential land use designation of the General Plan allows development with a unit density of 12-30 units per acre (Land Use and Community Design Element, page 2-11). The proposed project has a density of 20 units per acre, so it is consistent with this limit but does not meet the minimum density. The site also has a specific zoning of R-3 or High Density Multi-Family Residential, and the proposed project is also consistent with this zoning designation, but again does not meet the minimum density. The existing residential units in the SANTA ANITA RESIDENCE PROJECT INITIAL STUDY LSA SAA1401 29 area are multi-family in nature and 1-2 stories in height, so the proposed project would be consistent with the general character of the surrounding area. Therefore, there will be no significant impacts regarding land use consistency and compatibility. The project site is not designated for any type of habitat protection under the City’s General Plan, and is not covered by any adopted Habitat Conservation Plan or Natural Community Conservation Plan. Therefore, there will be no impacts in this regard. X.b.) Less than Significant Impact. The City of Arcadia is a charter city. Only 20 units are proposed which does not meet the minimum density of 23 units. This is due to the irregular shape of the lot and easements that must be maintained on the western portion of the lot, and therefore cannot be built on. Approval of a Zone Variance to allow fewer units would constitute acceptance by the City and would still be consistent with the General Plan. Therefore, the proposed project would have no significant land use impacts and no mitigation is required. XI. MINERAL RESOURCES Would the project: Potentially Significant Impact Less than Significant with Mitigation Incorporated Less than Significant Impact No Impact a) Result in the loss of availability of a known mineral resource that would be of value to the region and the residents of the state? b) Result in the loss of availability of a locally- important mineral resource recovery site delineated on a local general plan, specific plan or other land use plan? XI.a-b) The project site is within a fully developed portion of the City and does not contain, nor is it designated as, a source of mineral resources (e.g., construction aggregate). Therefore, there will be no impacts in this regard, and no mitigation is required. XII. NOISE Would the project result in: Potentially Significant Impact Less than Significant with Mitigation Incorporated Less than Significant Impact No Impact a) Exposure of persons to or generation of noise levels in excess of standards established in the local general plan or noise ordinance, or applicable standards of other agencies? SANTA ANITA RESIDENCE PROJECT INITIAL STUDY LSA SAA1401 30 b) Exposure of persons to or generation of excessive groundborne vibration or groundborne noise levels? c) Substantial permanent increase in ambient noise levels in the project vicinity above levels existing without the project? d) Substantial temporary or periodic increase in ambient noise levels in the project vicinity above levels existing without the project? e) For a project located within an airport land use plan or, where such a plan has not been adopted, within two miles of a public airport or public use airport, would the project expose people residing or working in the project area to excessive noise levels? f) For a project within the vicinity of a private airstrip, would the project expose people residing or working in the project area to excessive noise levels? XII.a-d) Less than Significant Impact. The City’s noise impact thresholds are outlined in the General Plan and the City’s Noise Ordinance. The project is consistent with onsite and area zoning, so noise impacts will be within General Plan standards. Construction of the proposed project is expected to require the use of earthmovers, bulldozers, and water and pickup trucks, however, the worst-case combined noise level during construction would not be expected to exceed 90 dBA Lmax at a distance of 50 feet from the active construction area. In addition, City staff would require the project to comply with the noise ordinance requirements for construction activities. Therefore, noise impacts of the project will comply with local regulations and would be less than significant. The Foothill Gold Line train line runs along the rear property line. The Environmental Impact Report (EIR) that was prepared in 2007 for the Gold Line Foothill Extension from Pasadena to Montclair, evaluated the impacts to the subject site but for the Church use. Since a residential use was not evaluated in the EIR, a train noise impact assessment for the proposed project was prepared by LSA Associates, Inc. (LSA December 2014)(Appendix D) to examine the potential train noise impacts of the proposed residential use. The City of Arcadia Noise Element of the General Plan establishes exterior noise criteria for outdoor living areas associated with residential uses. It requires that interior areas of new residential homes not exceed 45 dBA CNEL and that exterior active use areas not exceed 65 dBA CNEL. The City’s Noise Ordinance establishes the maximum permissible noise level that may intrude into a neighbor’s property. For Residential Zone, the exterior noise levels shall not exceed 55 dBA for more than 30 minutes in any hour during daytime hours between 7:00 a.m. and 10:00 p.m. For events occurring within shorter periods of time, the noise levels are adjusted upward accordingly. For events lasting equal to or less than 30 minutes but more than 15 minutes, the SANTA ANITA RESIDENCE PROJECT INITIAL STUDY LSA SAA1401 31 exterior noise shall not exceed 60 dBA during daytime hours. For events lasting equal to or less than 15 minutes but more than 5 minutes, the exterior noise shall not exceed 65 dBA during daytime hours. For events lasting equal to or less than 5 minutes but more than 1 minute, the exterior noise shall not exceed 70 dBA during daytime hours. At any time during daytime hours, the exterior noise shall not exceed 75 dBA The assessment determined that short- and long-term noise levels from the Foothill Gold Line would not exceed the City’s noise standards, so there will be no significant noise impacts on future project residents in that regard. The project is consistent with onsite and surrounding zoning, so the incremental vehicular traffic trips associated with the proposed project would not result in significant traffic noise impacts on off-site sensitive uses (i.e., Santa Anita Avenue and Colorado Boulevard are adjacent to the site). The project will comply with City design and construction requirements for multi-family development, so short- and long-term noise impacts are expected to be less than significant. XII.e-f) No Impact. The proposed project site is not located within an airport land use plan or within two miles of a public airport or private airstrip. Therefore, there would be no airport- related noise impacts related to the project. XIII. POPULATION AND HOUSING Would the project: Potentially Significant Impact Less than Significant with Mitigation Incorporated Less than Significant Impact No Impact a) Induce substantial population growth in an area, either directly (for example, by proposing new homes and businesses) or indirectly (for example, through extension of roads or other infrastructure)? b) Displace substantial numbers of existing housing, necessitating the construction of replacement housing elsewhere? c) Displace substantial numbers of people, necessitating the construction of replacement housing elsewhere? XIII.a) Less than Significant Impact. The proposed project would result in only minor population growth for the City. The site contains a former church so there are no residents or employees currently on the site. The proposed project could add 57 additional residents to the City, which is estimated based on 20 multi-family units times 2.83 persons per unit based on 2010 federal census data. This is less than what was projected for this lot since the proposed project does not meet the minimum density requirement of 23 units. SANTA ANITA RESIDENCE PROJECT INITIAL STUDY LSA SAA1401 32 XIII.b-c) No Impact. The project would result in demolition of the former church building but will not result in the loss of any current (i.e., baseline) employment since the church has already been closed, and the site did not contain any housing or residents so none would be lost by project development. XIV. PUBLIC SERVICES Potentially Significant Impact Less than Significant with Mitigation Incorporated Less than Significant Impact No Impact a) Would the project result in substantial adverse physical impacts associated with the provision of new or physically altered governmental facilities, need for new or physically altered governmental facilities, the construction of which could cause significant environmental impacts, in order to maintain acceptable service ratios, response times or other performance objectives for any of the public services:  Fire Protection?  Police Protection?  Schools?  Parks?  Other Public Facilities? XIV.a) Less than Significant Impact. The proposed project would replace a former church with 20 multi-family residential units that would generate incrementally more local traffic and population into the project area. This increase in population would incrementally increase the need for fire, police, parks, and other public facilities. However, these increases would be small and would not result in any significant public service impacts. The City will require the proposed project to pay all applicable Development Impact Fees to the City and to the local school district to alleviate potential impacts related to public services. XV. RECREATION Potentially Significant Impact Less than Significant with Mitigation Incorporated Less than Significant Impact No Impact a) Would the project increase the use of existing neighborhood and regional parks or other recreational facilities such that substantial physical deterioration of the facility would occur or be accelerated? SANTA ANITA RESIDENCE PROJECT INITIAL STUDY LSA SAA1401 33 b) Does the project include recreational facilities or require the construction or expansion or recreational facilities, which might have an adverse physical effect on the environment? XV.a-b) Less than Significant Impact. The project proposes 20 additional residential units that would require an incremental amount of additional recreational facilities or programs. Project residents would also be able to take advantage of existing City and County park facilities and services. The City will require the proposed project to pay applicable Development Impact Fees to the City for parks. XVI. TRANSPORTATION/TRAFFIC Would the project: Potentially Significant Impact Less than Significant with Mitigation Incorporated Less than Significant Impact No Impact a) Conflict with an applicable plan, ordinance or policy establishing measures of effectiveness for the performance of the circulation system, taking into account all modes of transportation including mass transit and non-motorized travel and relevant components of the circulation system, including but not limited to intersections, streets, highways and freeways, pedestrian and bicycle paths, and mass transit? b) Conflict with an applicable congestion management program, including, but not limited to level of service standards and travel demand measures, or other standards established by the county congestion management agency for designated roads or highways? c) Result in a change in air traffic patterns, including either an increase in traffic levels or a change in location that result in substantial safety risks? d) Substantially increase hazards due to a design feature (e.g., sharp curves or dangerous intersections) or incompatible uses (e.g., farm equipment)? e) Result in inadequate emergency access? SANTA ANITA RESIDENCE PROJECT INITIAL STUDY LSA SAA1401 34 f) Conflict with adopted policies, plans, or programs regarding public transit, bicycle, or pedestrian facilities, or otherwise decrease the performance or safety of such facilities? XVI.a-b) Less than Significant Impact. The project is very small and consistent with site zoning, so City staff determined that no formal traffic impact analysis was required. Trip generation for the proposed project is shown below and is based on rates from the Institute of Transportation Engineers (ITE) Trip Generation (9th Ed., 2013) for Land Use 230 “Residential Condominium/Townhouse.” The following summarizes the trip generation for the proposed project during the a.m. and p.m. peak hours. As shown below, the project is expected to generate 116 daily total trips, with 9 trips occurring the a.m. peak hour and 11 trips occurring during the p.m. peak hour. Land Use AM Peak Hour PM Peak Hour Daily Trips In Out Total In Out Total Condos/Townhomes (20) Dwelling Units Trips/Unit1 0.07 0.37 0.44 0.35 0.17 0.52 5.81 Trip Generation (rounded up) 2 8 9 7 4 11 116 Source: ITE 9th Ed, 2014 1 Rates based on Land Use 230 – “Residential Condominium/Townhouse” The former church on the site is not active at present, but the project would only generate an incremental amount of additional traffic during the peak hours. This small increase in ambient traffic is not expected to result in any significant traffic impacts to local roadways or intersections, or the nearby I-210 freeway ramps or mainline. The City of Arcadia utilizes County’s Congestion Management Program (CMP) traffic impact study guidelines that define a “significant traffic impact” as an increase in demand by at least 2 percent where the intersection would operate at LOS F with the project traffic. The small amount of traffic expected from the project will not exceed the CMP threshold of 50 peak hour trips to conduct an intersection analysis. Therefore, the project is not expected to produce any significant traffic volume impacts. Regarding parking, the site plan includes 50 parking spaces and the City requires 50 parking spaces. While parking was recently removed from the State CEQA Guidelines Appendix G Checklist as an environmental issue, it is nonetheless important to know how much parking is being provided by the project compared to how much is needed and/or required by the City to assure that project occupants will not have to park on adjacent properties due to a deficiency of onsite parking, which would be an indirect environmental impact affecting adjacent properties. In this case, there should be no such impacts. XVI.c-f) No Impact. The proposed project does not include uses or components that would affect air traffic, so no substantial safety risks would result from project implementation. No significant impacts would occur, and no mitigation is required. The proposed project will incrementally increase traffic onsite and on adjacent streets and intersections. The site plan indicates the project will take access from the established roadway SANTA ANITA RESIDENCE PROJECT INITIAL STUDY LSA SAA1401 35 connections (Windsor Road to the north to Newman Avenue, to Santa Anita Avenue), and will not create any new or unsafe driveways or access points. The project is also compatible with surrounding land uses. The Arcadia Police Department and the Arcadia Fire Station 106 are approximately three minutes or less from the project site in terms of response time (i.e., 0.85 mile and 1.85 miles @ 35 mph, respectively). Traffic associated with project construction may have a temporary effect on existing traffic circulation patterns. However, the proposed project is in a urban setting and direct access to the site will be available primarily from Santa Anita Avenue and secondary emergency access will be available via Cornell Drive. Due to the proximity of emergency services, the urban setting, and availability of access to the site impacts to emergency access will be less than significant. The proposed project will also comply with all of the City’s requirements for emergency access, so there will be no significant impacts. The project site is adjacent to Santa Anita Avenue and Colorado Boulevard which provide vehicular and non-vehicular access to the project area. City staff will also require the project to be consistent with City policies supporting public transit, bicycle, and pedestrian facilities, so there will be no significant impacts. XVII. UTILITIES AND SERVICE SYSTEMS Would the project: b) Require or result in the construction of new water or wastewater treatment facilities or expansion of existing facilities, the construction of which could cause significant environmental effects? c) Require or result in the construction of new stormwater drainage facilities or expansion of existing facilities, the construction of which could cause significant environmental effects? d) Have sufficient water supplies available to serve the project from existing entitlements and resources, or are new or expanded entitlements needed? Potentially Significant Impact Less than Significant with Mitigation Incorporated Less than Significant Impact No Impact a) Exceed wastewater treatment requirements of the applicable Regional Water Quality Control Board? SANTA ANITA RESIDENCE PROJECT INITIAL STUDY LSA SAA1401 36 e) Result in a determination by the wastewater treatment provider, which serves or may serve the project that it has adequate capacity to serve the project’s projected demand in addition to the provider’s existing commitments? f) Be served by a landfill with sufficient permitted capacity to accommodate the project’s solid waste disposal needs? g) Comply with federal, state, and local statutes and regulations related to solid waste? XVII.a-g) Less than Significant Impacts. The project site currently has a former church that when it operational it discharged its wastewater into the sanitary sewerage collection and treatment systems provided by the City of Arcadia and the County of Los Angeles, respectively. Under Section 402 of the Federal Clean Water Act (CWA), the Regional Water Quality Control Board (RWQCB) issues National Pollutant Discharge Elimination System (NPDES) permits to regulate waste discharges to “waters of the U.S.,” which includes rivers, lakes, and their tributary waters. Waste discharges include discharges of stormwater and construction project discharges. Construction of a project resulting in the disturbance of more than one acre requires an NPDES permit. Construction project proponents are also required to prepare a Storm Water Pollution Prevention Plan (SWPPP). Prior to the issuance of a grading permit, the project applicant would be required to satisfy City requirements related to the payment of fees and/or the provision of adequate wastewater facilities. The project would also have to comply with the waste discharge prohibitions and water quality objectives established by the RWCQB and the City as part of the development review and approval process. Therefore, project impacts related to this issue would be less than significant. Water and wastewater services are provided to the project site by the City of Arcadia Public Works Services Department. The department obtains water from both groundwater and imported water. The City also provides sewer service collection to the local area. Wastewater from the area is carried by sewers to the San Jose Creek Water Reclamation Plant which is operated by the Sanitation Districts of Los Angeles County. The project will not cause a need to construct any new water or wastewater treatment facilities, or expansion of existing facilities because these facilities are adequately sized to service the site, so there will be no significant impacts. A new sewer main will be constructed from Cornell Drive, adjacent to Unit 3, and tie into the existing sewer main adjacent to Colorado Blvd. A portion of the existing sewer main that runs southeast through the western portion of the site will be abandoned, and a sewer cleanout, cast iron sewer main will be constructed. Two existing manholes will be relocated and two new manholes will be constructed. A new storm drain pipe and catch basins will be constructed along the northerly property line, Windsor Road, and Cornell Drive to connect to new curb opening catch basin on Cornell Drive. This will connect to a new storm drain pipe and sewer manhole that will be constructed in the SANTA ANITA RESIDENCE PROJECT INITIAL STUDY LSA SAA1401 37 driveway between Unit 2 and 3 and will tie into an existing catch basin that will be modified adjacent to Colorado Boulevard. A new 30” storm drain pipe will be constructed from the modified catch basin and will run along Colorado Boulevard to N. Santa Anita Avenue. The new, modified, and relocated utilities are necessary to develop on the lot, however no expansion of these facilities are required as a result of the proposed project. Therefore the proposed project will have a less than significant impact on these facilities. Water service is provided to the project site by the City of Arcadia Public Works Services Department. The department obtains groundwater from the Main San Gabriel and Raymond Groundwater Basins. The City also obtains water imported from the Metropolitan Water District of Southern California (MWD) via the State Water Project and the Colorado River. According to MWD’s website, it will be able to meet the region’s water needs through 2030. In addition, the proposed project does not meet the threshold to prepare a project-specific Water Supply Assessment (WSA) under SB 610. Therefore, impacts related to water supply are considered to be less than significant. The proposed project would not increase the area population or otherwise induce substantial new population growth beyond that identified in the City’s General Plan (i.e., project is consistent with current zoning), as outlined in the previous Section XIII, Population and Housing. Therefore, impacts related to wastewater are less than significant. The City of Arcadia does not contract with a particular landfill. The proposed project would generate wastes both during construction and occupancy of the new townhomes. According to the California Recycle website, multi-family residences generate approximately 30 pounds of trash per unit per day, so the proposed project as a worst case scenario could generate up to 600 pounds of trash each day or 219,000 pounds per year. The proposed project would be required to comply with applicable elements of AB 1327, Chapter 18 (California Solid Waste Reuse and Recycling Access Act of 1991), and other applicable local, state, and federal solid waste disposal standards, thereby ensuring that impacts associated with this issue would be considered to be less than significant. SANTA ANITA RESIDENCE PROJECT INITIAL STUDY LSA SAA1401 38 XVIII. MANDATORY FINDINGS OF SIGNIFICANCE a) Does the project have the potential to degrade the quality of the environment, substantially reduce the habitat of a fish or wildlife species, cause a fish or wildlife population to drop below self-sustaining levels, threaten to eliminate a plant or animal community, reduce the number or restrict the range of a rare or endangered plant or animal or eliminate important examples of the major periods of California history or prehistory? Potentially Significant Impact Less than Significant with Mitigation Incorporated Less than Significant Impact No Impact XVIII.a) The project site is fully developed and contains no biological resources except for several landscaped trees. Development of the proposed project would not result in any significant impacts to listed or sensitive plants or animals, and it will comply with the City’s tree preservation ordinance. The project site does contain a structure that is over 50 years old; however, the structure was determined to not be a significant historic resource under CEQA. b) Does the project have impacts that are individually limited, but cumulatively considerable? (“Cumulatively considerable” means that the incremental effects of a project are considerable when viewed in connection with the effects of past projects, the effects of other current projects, and the effects of probable future projects.) Potentially Significant Impact Less than Significant with Mitigation Incorporated Less than Significant Impact No Impact XVIII.b) As presented in the discussion of environmental checklist questions I through XVII, the project will have no impacts or less than significant impacts with respect to all environmental issues. Due to the limited scope of direct physical impacts to the environment associated with this small development project (consistent with current zoning), the project will not have significant cumulative environmental impacts within the City or surrounding areas. c) Does the project have environmental effects that will cause substantial adverse effects on human beings, either directly or indirectly? Potentially Significant Impact Less than Significant with Mitigation Incorporated Less than Significant Impact No Impact XVIII.c) In general, impacts to human beings from the project may occur due to air pollutant emissions, hazards and hazardous materials, and noise. The South Coast Air Basin is currently designated as a non-attainment area for ozone, PM10, and PM2.5. Development of the project would contribute to air pollutant emissions on a short-term basis. The proposed project would be required to comply with regional rules that assist in reducing short-term air pollutant emissions. The analysis in Section III determined that this small project would not produce any significant short- and long-term air pollutant impacts from the project. SANTA ANITA RESIDENCE PROJECT INITIAL STUDY LSA SAA1401 39 In addition, the analyses in Sections VIII and IX, respectively, evaluated potential impacts related to hazards/hazardous materials and to water resources and determined there was either no impact or impacts were less than significant. As detailed in the preceding responses, development of the proposed project would not result, either directly or indirectly, in adverse hazards and noise effects, resulting in a corresponding less than significant impact to human beings. SANTA ANITA RESIDENCE PROJECT INITIAL STUDY LSA SAA1401 40 SECTION 5 LIST OF PREPARERS 5.1 LSA ASSOCIATES, INC. • Kent Norton, AICP, REPA (Project Manager) • Lynn Calvert-Hayes, AICP (Principal in Charge) • Tony Chung, Ph.D. (Noise/Air Quality/GHG Studies) • Katherine Best (Environmental Planner) • Casey Tibbet (Historical Assessment) • Margaret Gooding (Graphics) 5.2 CITY OF ARCADIA • Lisa Flores (Planning Services Manager) • Jordan Chamberlin (Assistant Planner) SANTA ANITA RESIDENCE PROJECT INITIAL STUDY LSA SAA1401 41 SECTION 6 REFERENCES Arcadia 2010 “City of Arcadia General Plan.” City of Arcadia. November 2010. BB&N 1987 “Noise Control for Buildings and Manufacturing Plants,” Bolt, Beranek & Newman (BB&N), 1987. CalEPA 2014 “Managing Hazardous Waste,” California Environmental Protection Agency (CalEPA) and Department of Toxic Substances Control, website accessed December 1, 2014. http://www.dtsc.ca.gov/hazardouswaste CalEPA 2014 “Certified Unified Program Agency (CUPA) Program Directory,” California Department Environmental Protection Agency (CalEPA), website accessed November 30, 2014. http://www.calepa.ca.gov/CUPA/Directory/default.aspx CALREC 2014 Calrecycle website accessed December 1, 2014. www.calrecycle.ca.gov Caltrans 2001 “Transportation Related Earthborne Vibrations (Caltrans Experiences)”. California Department of Transportation (Caltrans), Division of Environmental Analysis, Office of Noise, Air Quality, and Hazardous Waste Management. Technical Advisory, Vibration. TAV-02-01-R9601. February 20, 2001. Caltrans 2014 California Department of Transportation Scenic Highway Program, California Department of Transportation (Caltrans), website accessed December 2, 2014. http://www.dot.ca.gov/hq/LandArch/scenic_highways/scenic_hwy.htm CAPCOA 2008 “CEQA & Climate Change: Evaluating and Addressing Greenhouse Gas Emissions from Projects Subject to the California Environmental Quality Act,” California Air Pollution Control Officers Association (CAPCOA), January 2008. CARB 2007 “Proposed Early Actions to Mitigate Climate Change in California,” California Air Resources Board (CARB), April 20, 2007. CCCPP 2013 “Hydrofluorocarbon, Perfluorocarbon, and Sulfur Hexafluoride Emissions,” California Climate Change Policy and Program (CCCPP), California Climate Change Portal, website accessed July 21, 2013. http://www.climatechange.ca.gov/policies/1990s_in_depth/page11.html CCR 2013 “California Health and Safety Code,” Section 7050.5, California Code of Regulations (CCR). July 2013. SANTA ANITA RESIDENCE PROJECT INITIAL STUDY LSA SAA1401 42 CDC 2014 “Farmland Mapping and Monitoring Program,” California Department of Conservation (CDC), Division of Land Resource Protection. Website accessed November 28, 2014. CGS 2014 “Fault Mapping in California”. California Geological Survey (CGS). 2005. Website accessed November 29, 2014. CIWMB 2014 “Estimated Waste Generation Rates,” California Integrated Waste Management Board (CIWMB) website accessed on December 2, 2014. www.ciwmb.ca.gov/wastechar/wastegenrates/default.htm CWC 2014 “Sections 10750–10756,” California Water Code (CWC), California Department of Water Resources website accessed December 2, 2014. DOF 2014 “E-5 Population and Housing Estimates for Cities, Counties and the State, 2001-2010, with 2000 Benchmark.” State of California, Department of Finance (DOF), Sacramento, California, November 2014. DOT 2014 “Code of Federal Regulations, Title 49—Transportation, Pipeline and Hazardous Materials Safety Administration,” U.S. Department of Transportation (DOT), website site accessed December 3, 2014. http://ecfr.gpoaccess.gov/cgi/t/text/text- idx?sid=585c275ee19254ba07625d8c92fe925f&c=ecfr&tpl=/ecfrbrowse/ Title49/49cfrv2_02.tpl DTSC 2014 “Hazardous Waste and Substance Site (Cortese) List,” California Department of Toxic Substance Control (DTSC), website accessed December 3, 2014. http://www.envirostor.dtsc.ca.gov/public FEMA 2014 “Flood Limit Data and Mapping,” U.S. Federal Emergency Management Agency (FEMA), Flood Insurance Rate Map Program, website accessed December 1, 2014. Geotracker 2014 “Geotracker” database of hazardous material sites maintained by the Regional Water Quality Control Board, website accessed December 5, 2014. HII 2010 “City of Arcadia Zoning Map.” Hogle-Ireland Inc. 2010. LSA 2014 “Train Noise Impact Analysis.” LSA Associates, Inc. December 2014. NRCS 2014 “Soil Data Mart,” Natural Resources Conservation Service, United States Department of Agriculture, website accessed December 2, 2014. http://soildatamart.nrcs.usda.gov/Report.aspx?Survey=CA675&UseState =CA and as documented in the “Soil Survey of Los Angeles County, California” issued by the U.S. Department of Agriculture, Soil Conservation Service, original research dated 1971. SANTA ANITA RESIDENCE PROJECT INITIAL STUDY LSA SAA1401 43 PDA 2012 “Initial Study and Mitigated Negative Declaration, For Two Medical Office Buildings, A General Office Building, and a Four-Level Parking Structure at 161 Colorado Place and 125 W, Huntington Drive.” Pacific Design Group. December 2012. SCAG 2008 “Final 2008 Regional Comprehensive Plan,” Southern California Association of Governments (SCAG), adopted October 2, 2008. SCAG 2012a “2012-2035 Regional Transportation Plan/Sustainable Communities Strategy,” Southern California Association of Governments (SCAG), adopted April 2012. SCAG 2012b “Growth Forecast Appendix of the Regional Transportation Plan/Sustainable Communities Strategy” Southern California Association of Governments, adopted April 2012. http://rtpscs.scag.ca.gov/Documents/2012/pfinal/SR/2012pfRTP_Growth Forecast.pdf SCAQMD 2013 “Air Quality Management Plan,” South Coast Air Quality Management District (SCAQMD), 2013. SCAQMD 2014 SCAQMD website accessed December 2, 2014. www.aqmd.gov/ceqa/handbook/LST USEPA 1998 “AP-42 Emission Factors, Natural Gas Combustion,” U.S. Environmental Protection Agency (USEPA), July 1998. www.epa.gov/ttn/chief/ap42/ch01/final USEPA 2004a “EPA420-P-04-016: Update of Methane and Nitrous Oxide Emission Factors for On-Highway Vehicles,” U.S. Environmental Protection Agency (USEPA), prepared by ICF Consulting. November 2004. http://www.epa.gov/otaq/models/ngm USFWS 2011 “HCP/NCCP Planning Areas, Southern California,” U.S. Fish and Wildlife Service (USFWS), October 2011. SANTA ANITA RESIDENCE PROJECT INITIAL STUDY LSA SAA1401 Appendix A: Air Quality/Greenhouse Gas Information Project Characteristics - Land Use - Lot acreage, square feet: from project description Grading - Total acres: project description Demolition - Land Use Change - South Coast Air Basin, Summer Arcadia Multi-Family 1.1 Land Usage Land UsesSizeMetricLot AcreageFloor Surface AreaPopulation Apartments Low Rise20.00Dwelling Unit1.0540,438.0057 1.2 Other Project Characteristics Urbanization Climate Zone Urban 9 Wind Speed (m/s)Precipitation Freq (Days)2.231 1.3 User Entered Comments & Non-Default Data 1.0 Project Characteristics Utility CompanyStatewide Average 2014Operational Year CO2 Intensity (lb/MWhr) 1001.570.029CH4 Intensity (lb/MWhr) 0.006N2O Intensity (lb/MWhr) Table NameColumn NameDefault ValueNew Value tblGradingAcresOfGrading1.501.05 tblGradingAcresOfGrading1.001.05 tblLandUseLandUseSquareFeet20,000.0040,438.00 tblLandUseLotAcreage1.251.05 CalEEMod Version: CalEEMod.2013.2.2Date: 12/10/2014 10:03 AMPage 1 of 23 2.0 Emissions Summary 2.1 Overall Construction (Maximum Daily Emission) ROGNOxCOSO2Fugitive PM10 Exhaust PM10 PM10 Total Fugitive PM2.5 Exhaust PM2.5 PM2.5 Total Bio- CO2NBio- CO2Total CO2CH4N2OCO2e Yearlb/daylb/day 201532.049430.615323.56640.02845.91551.88117.38332.98031.76174.33070.00002,876.143 4 2,876.143 4 0.64600.00002,889.709 2 Total32.049430.615323.56640.02845.91551.88117.38332.98031.76174.33070.00002,876.143 4 2,876.143 4 0.64600.00002,889.709 2 Unmitigated Construction ROGNOxCOSO2Fugitive PM10 Exhaust PM10 PM10 Total Fugitive PM2.5 Exhaust PM2.5 PM2.5 Total Bio- CO2NBio- CO2Total CO2CH4N2OCO2e Yearlb/daylb/day 201532.049430.615323.56640.02845.91551.88117.38332.98031.76174.33070.00002,876.143 4 2,876.143 4 0.64600.00002,889.709 2 Total32.049430.615323.56640.02845.91551.88117.38332.98031.76174.33070.00002,876.143 4 2,876.143 4 0.64600.00002,889.709 2 Mitigated Construction CalEEMod Version: CalEEMod.2013.2.2Date: 12/10/2014 10:03 AMPage 2 of 23 ROGNOxCOSO2Fugitive PM10 Exhaust PM10 PM10 Total Fugitive PM2.5 Exhaust PM2.5 PM2.5 Total Bio- CO2NBio-CO2Total CO2CH4N20CO2e Percent Reduction 0.000.000.000.000.000.000.000.000.000.000.000.000.000.000.000.00 CalEEMod Version: CalEEMod.2013.2.2Date: 12/10/2014 10:03 AMPage 3 of 23 2.2 Overall Operational ROGNOxCOSO2Fugitive PM10 Exhaust PM10 PM10 Total Fugitive PM2.5 Exhaust PM2.5 PM2.5 Total Bio- CO2NBio- CO2Total CO2CH4N2OCO2e Categorylb/daylb/day Area6.18320.153011.74320.01611.53671.53671.53651.5365187.3384362.9711550.30940.56190.0127566.0499 Energy8.4100e- 003 0.07190.03064.6000e- 004 5.8100e- 003 5.8100e- 003 5.8100e- 003 5.8100e- 003 91.741391.74131.7600e- 003 1.6800e- 003 92.2996 Mobile0.64871.88087.75840.01541.03690.03001.06690.27700.02750.30451,422.995 9 1,422.995 9 0.06321,424.322 1 Total6.84032.105619.53220.03191.03691.57252.60950.27701.56981.8468187.33841,877.708 3 2,065.046 7 0.62680.01442,082.671 6 Unmitigated Operational ROGNOxCOSO2Fugitive PM10 Exhaust PM10 PM10 Total Fugitive PM2.5 Exhaust PM2.5 PM2.5 Total Bio- CO2NBio- CO2Total CO2CH4N2OCO2e Categorylb/daylb/day Area6.18320.153011.74320.01611.53671.53671.53651.5365187.3384362.9711550.30940.56190.0127566.0499 Energy8.4100e- 003 0.07190.03064.6000e- 004 5.8100e- 003 5.8100e- 003 5.8100e- 003 5.8100e- 003 91.741391.74131.7600e- 003 1.6800e- 003 92.2996 Mobile0.64871.88087.75840.01541.03690.03001.06690.27700.02750.30451,422.995 9 1,422.995 9 0.06321,424.322 1 Total6.84032.105619.53220.03191.03691.57252.60950.27701.56981.8468187.33841,877.708 3 2,065.046 7 0.62680.01442,082.671 6 Mitigated Operational CalEEMod Version: CalEEMod.2013.2.2Date: 12/10/2014 10:03 AMPage 4 of 23 3.0 Construction Detail Construction Phase Phase Number Phase NamePhase TypeStart DateEnd DateNum Days Week Num DaysPhase Description 1DemolitionDemolition1/1/20151/28/2015520 2Site PreparationSite Preparation1/29/20151/30/201552 3GradingGrading1/31/20152/5/201554 4Building ConstructionBuilding Construction2/6/201511/12/20155200 5PavingPaving11/13/201511/26/2015510 6Architectural CoatingArchitectural Coating11/27/201512/10/2015510 OffRoad Equipment ROGNOxCOSO2Fugitive PM10 Exhaust PM10 PM10 Total Fugitive PM2.5 Exhaust PM2.5 PM2.5 Total Bio- CO2NBio-CO2Total CO2CH4N20CO2e Percent Reduction 0.000.000.000.000.000.000.000.000.000.000.000.000.000.000.000.00 Residential Indoor: 81,887; Residential Outdoor: 27,296; Non-Residential Indoor: 0; Non-Residential Outdoor: 0 (Architectural Coating – sqft) Acres of Grading (Site Preparation Phase): 1.05 Acres of Grading (Grading Phase): 1.05 Acres of Paving: 0 CalEEMod Version: CalEEMod.2013.2.2Date: 12/10/2014 10:03 AMPage 5 of 23 Phase NameOffroad Equipment TypeAmountUsage HoursHorse PowerLoad Factor Architectural CoatingAir Compressors16.00780.48 PavingCement and Mortar Mixers16.0090.56 DemolitionConcrete/Industrial Saws18.00810.73 Building ConstructionGenerator Sets18.00840.74 Building ConstructionCranes16.002260.29 Building ConstructionForklifts16.00890.20 Site PreparationGraders18.001740.41 PavingPavers16.001250.42 PavingRollers17.00800.38 DemolitionRubber Tired Dozers18.002550.40 GradingRubber Tired Dozers16.002550.40 Building ConstructionTractors/Loaders/Backhoes16.00970.37 DemolitionTractors/Loaders/Backhoes38.00970.37 GradingTractors/Loaders/Backhoes17.00970.37 PavingTractors/Loaders/Backhoes18.00970.37 Site PreparationTractors/Loaders/Backhoes18.00970.37 GradingGraders16.001740.41 PavingPaving Equipment18.001300.36 Site PreparationRubber Tired Dozers17.002550.40 Building ConstructionWelders38.00460.45 Trips and VMT CalEEMod Version: CalEEMod.2013.2.2Date: 12/10/2014 10:03 AMPage 6 of 23 3.2 Demolition - 2015 ROGNOxCOSO2Fugitive PM10 Exhaust PM10 PM10 Total Fugitive PM2.5 Exhaust PM2.5 PM2.5 Total Bio- CO2NBio- CO2Total CO2CH4N2OCO2e Categorylb/daylb/day Fugitive Dust0.59290.00000.59290.08980.00000.08980.00000.0000 Off-Road3.066629.677822.05660.02451.86511.86511.74691.74692,509.059 9 2,509.059 9 0.63572,522.410 4 Total3.066629.677822.05660.02450.59291.86512.45800.08981.74691.83672,509.059 9 2,509.059 9 0.63572,522.410 4 Unmitigated Construction On-Site 3.1 Mitigation Measures Construction Phase NameOffroad Equipment Count Worker Trip Number Vendor Trip Number Hauling Trip Number Worker Trip Length Vendor Trip Length Hauling Trip Length Worker Vehicle Class Vendor Vehicle Class Hauling Vehicle Class Demolition513.000.0055.0014.706.9020.00LD_MixHDT_MixHHDT Site Preparation38.000.000.0014.706.9020.00LD_MixHDT_MixHHDT Grading38.000.000.0014.706.9020.00LD_MixHDT_MixHHDT Building Construction714.002.000.0014.706.9020.00LD_MixHDT_MixHHDT Paving513.000.000.0014.706.9020.00LD_MixHDT_MixHHDT Architectural Coating13.000.000.0014.706.9020.00LD_MixHDT_MixHHDT CalEEMod Version: CalEEMod.2013.2.2Date: 12/10/2014 10:03 AMPage 7 of 23 3.2 Demolition - 2015 ROGNOxCOSO2Fugitive PM10 Exhaust PM10 PM10 Total Fugitive PM2.5 Exhaust PM2.5 PM2.5 Total Bio- CO2NBio- CO2Total CO2CH4N2OCO2e Categorylb/daylb/day Hauling0.05370.86250.57862.0300e- 003 0.04790.01470.06260.01310.01360.0267206.9194206.91941.6300e- 003 206.9538 Vendor0.00000.00000.00000.00000.00000.00000.00000.00000.00000.00000.00000.00000.00000.0000 Worker0.06000.07500.93121.8400e- 003 0.14531.2800e- 003 0.14660.03851.1700e- 003 0.0397160.1641160.16418.6200e- 003 160.3451 Total0.11370.93751.50983.8700e- 003 0.19320.01600.20920.05170.01470.0664367.0836367.08360.0103367.2988 Unmitigated Construction Off-Site ROGNOxCOSO2Fugitive PM10 Exhaust PM10 PM10 Total Fugitive PM2.5 Exhaust PM2.5 PM2.5 Total Bio- CO2NBio- CO2Total CO2CH4N2OCO2e Categorylb/daylb/day Fugitive Dust0.59290.00000.59290.08980.00000.08980.00000.0000 Off-Road3.066629.677822.05660.02451.86511.86511.74691.74690.00002,509.059 9 2,509.059 9 0.63572,522.410 4 Total3.066629.677822.05660.02450.59291.86512.45800.08981.74691.83670.00002,509.059 9 2,509.059 9 0.63572,522.410 4 Mitigated Construction On-Site CalEEMod Version: CalEEMod.2013.2.2Date: 12/10/2014 10:03 AMPage 8 of 23 3.2 Demolition - 2015 ROGNOxCOSO2Fugitive PM10 Exhaust PM10 PM10 Total Fugitive PM2.5 Exhaust PM2.5 PM2.5 Total Bio- CO2NBio- CO2Total CO2CH4N2OCO2e Categorylb/daylb/day Hauling0.05370.86250.57862.0300e- 003 0.04790.01470.06260.01310.01360.0267206.9194206.91941.6300e- 003 206.9538 Vendor0.00000.00000.00000.00000.00000.00000.00000.00000.00000.00000.00000.00000.00000.0000 Worker0.06000.07500.93121.8400e- 003 0.14531.2800e- 003 0.14660.03851.1700e- 003 0.0397160.1641160.16418.6200e- 003 160.3451 Total0.11370.93751.50983.8700e- 003 0.19320.01600.20920.05170.01470.0664367.0836367.08360.0103367.2988 Mitigated Construction Off-Site 3.3 Site Preparation - 2015 ROGNOxCOSO2Fugitive PM10 Exhaust PM10 PM10 Total Fugitive PM2.5 Exhaust PM2.5 PM2.5 Total Bio- CO2NBio- CO2Total CO2CH4N2OCO2e Categorylb/daylb/day Fugitive Dust5.82610.00005.82612.95660.00002.95660.00000.0000 Off-Road2.536226.888617.01070.01711.46711.46711.34971.34971,801.744 0 1,801.744 0 0.53791,813.039 8 Total2.536226.888617.01070.01715.82611.46717.29312.95661.34974.30631,801.744 0 1,801.744 0 0.53791,813.039 8 Unmitigated Construction On-Site CalEEMod Version: CalEEMod.2013.2.2Date: 12/10/2014 10:03 AMPage 9 of 23 3.3 Site Preparation - 2015 ROGNOxCOSO2Fugitive PM10 Exhaust PM10 PM10 Total Fugitive PM2.5 Exhaust PM2.5 PM2.5 Total Bio- CO2NBio- CO2Total CO2CH4N2OCO2e Categorylb/daylb/day Hauling0.00000.00000.00000.00000.00000.00000.00000.00000.00000.00000.00000.00000.00000.0000 Vendor0.00000.00000.00000.00000.00000.00000.00000.00000.00000.00000.00000.00000.00000.0000 Worker0.03690.04620.57311.1300e- 003 0.08947.9000e- 004 0.09020.02377.2000e- 004 0.024498.562598.56255.3000e- 003 98.6739 Total0.03690.04620.57311.1300e- 003 0.08947.9000e- 004 0.09020.02377.2000e- 004 0.024498.562598.56255.3000e- 003 98.6739 Unmitigated Construction Off-Site ROGNOxCOSO2Fugitive PM10 Exhaust PM10 PM10 Total Fugitive PM2.5 Exhaust PM2.5 PM2.5 Total Bio- CO2NBio- CO2Total CO2CH4N2OCO2e Categorylb/daylb/day Fugitive Dust5.82610.00005.82612.95660.00002.95660.00000.0000 Off-Road2.536226.888617.01070.01711.46711.46711.34971.34970.00001,801.744 0 1,801.744 0 0.53791,813.039 8 Total2.536226.888617.01070.01715.82611.46717.29312.95661.34974.30630.00001,801.744 0 1,801.744 0 0.53791,813.039 8 Mitigated Construction On-Site CalEEMod Version: CalEEMod.2013.2.2Date: 12/10/2014 10:03 AMPage 10 of 23 3.3 Site Preparation - 2015 ROGNOxCOSO2Fugitive PM10 Exhaust PM10 PM10 Total Fugitive PM2.5 Exhaust PM2.5 PM2.5 Total Bio- CO2NBio- CO2Total CO2CH4N2OCO2e Categorylb/daylb/day Hauling0.00000.00000.00000.00000.00000.00000.00000.00000.00000.00000.00000.00000.00000.0000 Vendor0.00000.00000.00000.00000.00000.00000.00000.00000.00000.00000.00000.00000.00000.0000 Worker0.03690.04620.57311.1300e- 003 0.08947.9000e- 004 0.09020.02377.2000e- 004 0.024498.562598.56255.3000e- 003 98.6739 Total0.03690.04620.57311.1300e- 003 0.08947.9000e- 004 0.09020.02377.2000e- 004 0.024498.562598.56255.3000e- 003 98.6739 Mitigated Construction Off-Site 3.4 Grading - 2015 ROGNOxCOSO2Fugitive PM10 Exhaust PM10 PM10 Total Fugitive PM2.5 Exhaust PM2.5 PM2.5 Total Bio- CO2NBio- CO2Total CO2CH4N2OCO2e Categorylb/daylb/day Fugitive Dust4.79500.00004.79502.51270.00002.51270.00000.0000 Off-Road2.066621.944314.09020.01411.19681.19681.10111.10111,479.800 0 1,479.800 0 0.44181,489.077 4 Total2.066621.944314.09020.01414.79501.19685.99172.51271.10113.61381,479.800 0 1,479.800 0 0.44181,489.077 4 Unmitigated Construction On-Site CalEEMod Version: CalEEMod.2013.2.2Date: 12/10/2014 10:03 AMPage 11 of 23 3.4 Grading - 2015 ROGNOxCOSO2Fugitive PM10 Exhaust PM10 PM10 Total Fugitive PM2.5 Exhaust PM2.5 PM2.5 Total Bio- CO2NBio- CO2Total CO2CH4N2OCO2e Categorylb/daylb/day Hauling0.00000.00000.00000.00000.00000.00000.00000.00000.00000.00000.00000.00000.00000.0000 Vendor0.00000.00000.00000.00000.00000.00000.00000.00000.00000.00000.00000.00000.00000.0000 Worker0.03690.04620.57311.1300e- 003 0.08947.9000e- 004 0.09020.02377.2000e- 004 0.024498.562598.56255.3000e- 003 98.6739 Total0.03690.04620.57311.1300e- 003 0.08947.9000e- 004 0.09020.02377.2000e- 004 0.024498.562598.56255.3000e- 003 98.6739 Unmitigated Construction Off-Site ROGNOxCOSO2Fugitive PM10 Exhaust PM10 PM10 Total Fugitive PM2.5 Exhaust PM2.5 PM2.5 Total Bio- CO2NBio- CO2Total CO2CH4N2OCO2e Categorylb/daylb/day Fugitive Dust4.79500.00004.79502.51270.00002.51270.00000.0000 Off-Road2.066621.944314.09020.01411.19681.19681.10111.10110.00001,479.800 0 1,479.800 0 0.44181,489.077 4 Total2.066621.944314.09020.01414.79501.19685.99172.51271.10113.61380.00001,479.800 0 1,479.800 0 0.44181,489.077 4 Mitigated Construction On-Site CalEEMod Version: CalEEMod.2013.2.2Date: 12/10/2014 10:03 AMPage 12 of 23 3.4 Grading - 2015 ROGNOxCOSO2Fugitive PM10 Exhaust PM10 PM10 Total Fugitive PM2.5 Exhaust PM2.5 PM2.5 Total Bio- CO2NBio- CO2Total CO2CH4N2OCO2e Categorylb/daylb/day Hauling0.00000.00000.00000.00000.00000.00000.00000.00000.00000.00000.00000.00000.00000.0000 Vendor0.00000.00000.00000.00000.00000.00000.00000.00000.00000.00000.00000.00000.00000.0000 Worker0.03690.04620.57311.1300e- 003 0.08947.9000e- 004 0.09020.02377.2000e- 004 0.024498.562598.56255.3000e- 003 98.6739 Total0.03690.04620.57311.1300e- 003 0.08947.9000e- 004 0.09020.02377.2000e- 004 0.024498.562598.56255.3000e- 003 98.6739 Mitigated Construction Off-Site 3.5 Building Construction - 2015 ROGNOxCOSO2Fugitive PM10 Exhaust PM10 PM10 Total Fugitive PM2.5 Exhaust PM2.5 PM2.5 Total Bio- CO2NBio- CO2Total CO2CH4N2OCO2e Categorylb/daylb/day Off-Road3.600021.564215.00410.02201.48511.48511.43441.43442,055.624 7 2,055.624 7 0.47412,065.581 2 Total3.600021.564215.00410.02201.48511.48511.43441.43442,055.624 7 2,055.624 7 0.47412,065.581 2 Unmitigated Construction On-Site CalEEMod Version: CalEEMod.2013.2.2Date: 12/10/2014 10:03 AMPage 13 of 23 3.5 Building Construction - 2015 ROGNOxCOSO2Fugitive PM10 Exhaust PM10 PM10 Total Fugitive PM2.5 Exhaust PM2.5 PM2.5 Total Bio- CO2NBio- CO2Total CO2CH4N2OCO2e Categorylb/daylb/day Hauling0.00000.00000.00000.00000.00000.00000.00000.00000.00000.00000.00000.00000.00000.0000 Vendor0.01890.19650.21684.4000e- 004 0.01253.4000e- 003 0.01593.5600e- 003 3.1200e- 003 6.6800e- 003 44.124544.12453.5000e- 004 44.1318 Worker0.06460.08081.00281.9800e- 003 0.15651.3800e- 003 0.15790.04151.2600e- 003 0.0428172.4844172.48449.2800e- 003 172.6793 Total0.08350.27731.21972.4200e- 003 0.16904.7800e- 003 0.17380.04514.3800e- 003 0.0494216.6090216.60909.6300e- 003 216.8111 Unmitigated Construction Off-Site ROGNOxCOSO2Fugitive PM10 Exhaust PM10 PM10 Total Fugitive PM2.5 Exhaust PM2.5 PM2.5 Total Bio- CO2NBio- CO2Total CO2CH4N2OCO2e Categorylb/daylb/day Off-Road3.600021.564215.00410.02201.48511.48511.43441.43440.00002,055.624 7 2,055.624 7 0.47412,065.581 2 Total3.600021.564215.00410.02201.48511.48511.43441.43440.00002,055.624 7 2,055.624 7 0.47412,065.581 2 Mitigated Construction On-Site CalEEMod Version: CalEEMod.2013.2.2Date: 12/10/2014 10:03 AMPage 14 of 23 3.5 Building Construction - 2015 ROGNOxCOSO2Fugitive PM10 Exhaust PM10 PM10 Total Fugitive PM2.5 Exhaust PM2.5 PM2.5 Total Bio- CO2NBio- CO2Total CO2CH4N2OCO2e Categorylb/daylb/day Hauling0.00000.00000.00000.00000.00000.00000.00000.00000.00000.00000.00000.00000.00000.0000 Vendor0.01890.19650.21684.4000e- 004 0.01253.4000e- 003 0.01593.5600e- 003 3.1200e- 003 6.6800e- 003 44.124544.12453.5000e- 004 44.1318 Worker0.06460.08081.00281.9800e- 003 0.15651.3800e- 003 0.15790.04151.2600e- 003 0.0428172.4844172.48449.2800e- 003 172.6793 Total0.08350.27731.21972.4200e- 003 0.16904.7800e- 003 0.17380.04514.3800e- 003 0.0494216.6090216.60909.6300e- 003 216.8111 Mitigated Construction Off-Site 3.6 Paving - 2015 ROGNOxCOSO2Fugitive PM10 Exhaust PM10 PM10 Total Fugitive PM2.5 Exhaust PM2.5 PM2.5 Total Bio- CO2NBio- CO2Total CO2CH4N2OCO2e Categorylb/daylb/day Off-Road1.404114.59599.16950.01330.89190.89190.82150.82151,382.470 3 1,382.470 3 0.40541,390.982 6 Paving0.00000.00000.00000.00000.00000.00000.0000 Total1.404114.59599.16950.01330.89190.89190.82150.82151,382.470 3 1,382.470 3 0.40541,390.982 6 Unmitigated Construction On-Site CalEEMod Version: CalEEMod.2013.2.2Date: 12/10/2014 10:03 AMPage 15 of 23 3.6 Paving - 2015 ROGNOxCOSO2Fugitive PM10 Exhaust PM10 PM10 Total Fugitive PM2.5 Exhaust PM2.5 PM2.5 Total Bio- CO2NBio- CO2Total CO2CH4N2OCO2e Categorylb/daylb/day Hauling0.00000.00000.00000.00000.00000.00000.00000.00000.00000.00000.00000.00000.00000.0000 Vendor0.00000.00000.00000.00000.00000.00000.00000.00000.00000.00000.00000.00000.00000.0000 Worker0.06000.07500.93121.8400e- 003 0.14531.2800e- 003 0.14660.03851.1700e- 003 0.0397160.1641160.16418.6200e- 003 160.3451 Total0.06000.07500.93121.8400e- 003 0.14531.2800e- 003 0.14660.03851.1700e- 003 0.0397160.1641160.16418.6200e- 003 160.3451 Unmitigated Construction Off-Site ROGNOxCOSO2Fugitive PM10 Exhaust PM10 PM10 Total Fugitive PM2.5 Exhaust PM2.5 PM2.5 Total Bio- CO2NBio- CO2Total CO2CH4N2OCO2e Categorylb/daylb/day Off-Road1.404114.59599.16950.01330.89190.89190.82150.82150.00001,382.470 3 1,382.470 3 0.40541,390.982 6 Paving0.00000.00000.00000.00000.00000.00000.0000 Total1.404114.59599.16950.01330.89190.89190.82150.82150.00001,382.470 3 1,382.470 3 0.40541,390.982 6 Mitigated Construction On-Site CalEEMod Version: CalEEMod.2013.2.2Date: 12/10/2014 10:03 AMPage 16 of 23 3.6 Paving - 2015 ROGNOxCOSO2Fugitive PM10 Exhaust PM10 PM10 Total Fugitive PM2.5 Exhaust PM2.5 PM2.5 Total Bio- CO2NBio- CO2Total CO2CH4N2OCO2e Categorylb/daylb/day Hauling0.00000.00000.00000.00000.00000.00000.00000.00000.00000.00000.00000.00000.00000.0000 Vendor0.00000.00000.00000.00000.00000.00000.00000.00000.00000.00000.00000.00000.00000.0000 Worker0.06000.07500.93121.8400e- 003 0.14531.2800e- 003 0.14660.03851.1700e- 003 0.0397160.1641160.16418.6200e- 003 160.3451 Total0.06000.07500.93121.8400e- 003 0.14531.2800e- 003 0.14660.03851.1700e- 003 0.0397160.1641160.16418.6200e- 003 160.3451 Mitigated Construction Off-Site 3.7 Architectural Coating - 2015 ROGNOxCOSO2Fugitive PM10 Exhaust PM10 PM10 Total Fugitive PM2.5 Exhaust PM2.5 PM2.5 Total Bio- CO2NBio- CO2Total CO2CH4N2OCO2e Categorylb/daylb/day Archit. Coating31.62900.00000.00000.00000.00000.00000.0000 Off-Road0.40662.57031.90182.9700e- 003 0.22090.22090.22090.2209281.4481281.44810.0367282.2177 Total32.03562.57031.90182.9700e- 003 0.22090.22090.22090.2209281.4481281.44810.0367282.2177 Unmitigated Construction On-Site CalEEMod Version: CalEEMod.2013.2.2Date: 12/10/2014 10:03 AMPage 17 of 23 3.7 Architectural Coating - 2015 ROGNOxCOSO2Fugitive PM10 Exhaust PM10 PM10 Total Fugitive PM2.5 Exhaust PM2.5 PM2.5 Total Bio- CO2NBio- CO2Total CO2CH4N2OCO2e Categorylb/daylb/day Hauling0.00000.00000.00000.00000.00000.00000.00000.00000.00000.00000.00000.00000.00000.0000 Vendor0.00000.00000.00000.00000.00000.00000.00000.00000.00000.00000.00000.00000.00000.0000 Worker0.01380.01730.21494.3000e- 004 0.03353.0000e- 004 0.03388.8900e- 003 2.7000e- 004 9.1600e- 003 36.961036.96101.9900e- 003 37.0027 Total0.01380.01730.21494.3000e- 004 0.03353.0000e- 004 0.03388.8900e- 003 2.7000e- 004 9.1600e- 003 36.961036.96101.9900e- 003 37.0027 Unmitigated Construction Off-Site ROGNOxCOSO2Fugitive PM10 Exhaust PM10 PM10 Total Fugitive PM2.5 Exhaust PM2.5 PM2.5 Total Bio- CO2NBio- CO2Total CO2CH4N2OCO2e Categorylb/daylb/day Archit. Coating31.62900.00000.00000.00000.00000.00000.0000 Off-Road0.40662.57031.90182.9700e- 003 0.22090.22090.22090.22090.0000281.4481281.44810.0367282.2177 Total32.03562.57031.90182.9700e- 003 0.22090.22090.22090.22090.0000281.4481281.44810.0367282.2177 Mitigated Construction On-Site CalEEMod Version: CalEEMod.2013.2.2Date: 12/10/2014 10:03 AMPage 18 of 23 4.0 Operational Detail - Mobile ROGNOxCOSO2Fugitive PM10 Exhaust PM10 PM10 Total Fugitive PM2.5 Exhaust PM2.5 PM2.5 Total Bio- CO2NBio- CO2Total CO2CH4N2OCO2e Categorylb/daylb/day Mitigated0.64871.88087.75840.01541.03690.03001.06690.27700.02750.30451,422.995 9 1,422.995 9 0.06321,424.322 1 Unmitigated0.64871.88087.75840.01541.03690.03001.06690.27700.02750.30451,422.995 9 1,422.995 9 0.06321,424.322 1 4.1 Mitigation Measures Mobile 3.7 Architectural Coating - 2015 ROGNOxCOSO2Fugitive PM10 Exhaust PM10 PM10 Total Fugitive PM2.5 Exhaust PM2.5 PM2.5 Total Bio- CO2NBio- CO2Total CO2CH4N2OCO2e Categorylb/daylb/day Hauling0.00000.00000.00000.00000.00000.00000.00000.00000.00000.00000.00000.00000.00000.0000 Vendor0.00000.00000.00000.00000.00000.00000.00000.00000.00000.00000.00000.00000.00000.0000 Worker0.01380.01730.21494.3000e- 004 0.03353.0000e- 004 0.03388.8900e- 003 2.7000e- 004 9.1600e- 003 36.961036.96101.9900e- 003 37.0027 Total0.01380.01730.21494.3000e- 004 0.03353.0000e- 004 0.03388.8900e- 003 2.7000e- 004 9.1600e- 003 36.961036.96101.9900e- 003 37.0027 Mitigated Construction Off-Site CalEEMod Version: CalEEMod.2013.2.2Date: 12/10/2014 10:03 AMPage 19 of 23 4.2 Trip Summary Information 4.3 Trip Type Information Average Daily Trip RateUnmitigatedMitigated Land UseWeekdaySaturdaySundayAnnual VMTAnnual VMT Apartments Low Rise131.80143.20121.40450,869450,869 Total131.80143.20121.40450,869450,869 MilesTrip %Trip Purpose % Land UseH-W or C-WH-S or C-CH-O or C-NWH-W or C-WH-S or C-CH-O or C-NWPrimaryDivertedPass-by Apartments Low Rise14.705.908.7040.2019.2040.6086113 5.0 Energy Detail ROGNOxCOSO2Fugitive PM10 Exhaust PM10 PM10 Total Fugitive PM2.5 Exhaust PM2.5 PM2.5 Total Bio- CO2NBio- CO2Total CO2CH4N2OCO2e Categorylb/daylb/day NaturalGas Mitigated 8.4100e- 003 0.07190.03064.6000e- 004 5.8100e- 003 5.8100e- 003 5.8100e- 003 5.8100e- 003 91.741391.74131.7600e- 003 1.6800e- 003 92.2996 NaturalGas Unmitigated 8.4100e- 003 0.07190.03064.6000e- 004 5.8100e- 003 5.8100e- 003 5.8100e- 003 5.8100e- 003 91.741391.74131.7600e- 003 1.6800e- 003 92.2996 5.1 Mitigation Measures Energy 4.4 Fleet Mix LDALDT1LDT2MDVLHD1LHD2MHDHHDOBUSUBUSMCYSBUSMH 0.5166100.0605170.1799790.1405870.0415660.0066160.0150920.0275870.0019230.0025300.0043140.0006020.002075 Historical Energy Use: N CalEEMod Version: CalEEMod.2013.2.2Date: 12/10/2014 10:03 AMPage 20 of 23 6.1 Mitigation Measures Area 6.0 Area Detail 5.2 Energy by Land Use - NaturalGas NaturalGa s Use ROGNOxCOSO2Fugitive PM10 Exhaust PM10 PM10 Total Fugitive PM2.5 Exhaust PM2.5 PM2.5 Total Bio- CO2NBio- CO2Total CO2CH4N2OCO2e Land UsekBTU/yrlb/daylb/day Apartments Low Rise 779.8018.4100e- 003 0.07190.03064.6000e- 004 5.8100e- 003 5.8100e- 003 5.8100e- 003 5.8100e- 003 91.741391.74131.7600e- 003 1.6800e- 003 92.2996 Total8.4100e- 003 0.07190.03064.6000e- 004 5.8100e- 003 5.8100e- 003 5.8100e- 003 5.8100e- 003 91.741391.74131.7600e- 003 1.6800e- 003 92.2996 Unmitigated NaturalGa s Use ROGNOxCOSO2Fugitive PM10 Exhaust PM10 PM10 Total Fugitive PM2.5 Exhaust PM2.5 PM2.5 Total Bio- CO2NBio- CO2Total CO2CH4N2OCO2e Land UsekBTU/yrlb/daylb/day Apartments Low Rise 0.7798018.4100e- 003 0.07190.03064.6000e- 004 5.8100e- 003 5.8100e- 003 5.8100e- 003 5.8100e- 003 91.741391.74131.7600e- 003 1.6800e- 003 92.2996 Total8.4100e- 003 0.07190.03064.6000e- 004 5.8100e- 003 5.8100e- 003 5.8100e- 003 5.8100e- 003 91.741391.74131.7600e- 003 1.6800e- 003 92.2996 Mitigated CalEEMod Version: CalEEMod.2013.2.2Date: 12/10/2014 10:03 AMPage 21 of 23 ROGNOxCOSO2Fugitive PM10 Exhaust PM10 PM10 Total Fugitive PM2.5 Exhaust PM2.5 PM2.5 Total Bio- CO2NBio- CO2Total CO2CH4N2OCO2e Categorylb/daylb/day Mitigated6.18320.153011.74320.01611.53671.53671.53651.5365187.3384362.9711550.30940.56190.0127566.0499 Unmitigated6.18320.153011.74320.01611.53671.53671.53651.5365187.3384362.9711550.30940.56190.0127566.0499 6.2 Area by SubCategory ROGNOxCOSO2Fugitive PM10 Exhaust PM10 PM10 Total Fugitive PM2.5 Exhaust PM2.5 PM2.5 Total Bio- CO2NBio- CO2Total CO2CH4N2OCO2e SubCategorylb/daylb/day Architectural Coating 0.08670.00000.00000.00000.00000.00000.0000 Consumer Products 0.80070.00000.00000.00000.00000.00000.0000 Hearth5.24070.133010.05280.01601.52781.52781.52751.5275187.3384360.0000547.33840.55870.0127563.0123 Landscaping0.05510.02001.69039.0000e- 005 8.9800e- 003 8.9800e- 003 8.9800e- 003 8.9800e- 003 2.97112.97113.1700e- 003 3.0376 Total6.18320.153011.74320.01611.53681.53681.53651.5365187.3384362.9711550.30940.56190.0127566.0499 Unmitigated CalEEMod Version: CalEEMod.2013.2.2Date: 12/10/2014 10:03 AMPage 22 of 23 8.1 Mitigation Measures Waste 7.1 Mitigation Measures Water 7.0 Water Detail 8.0 Waste Detail 10.0 Vegetation 6.2 Area by SubCategory ROGNOxCOSO2Fugitive PM10 Exhaust PM10 PM10 Total Fugitive PM2.5 Exhaust PM2.5 PM2.5 Total Bio- CO2NBio- CO2Total CO2CH4N2OCO2e SubCategorylb/daylb/day Consumer Products 0.80070.00000.00000.00000.00000.00000.0000 Hearth5.24070.133010.05280.01601.52781.52781.52751.5275187.3384360.0000547.33840.55870.0127563.0123 Landscaping0.05510.02001.69039.0000e- 005 8.9800e- 003 8.9800e- 003 8.9800e- 003 8.9800e- 003 2.97112.97113.1700e- 003 3.0376 Architectural Coating 0.08670.00000.00000.00000.00000.00000.0000 Total6.18320.153011.74320.01611.53681.53681.53651.5365187.3384362.9711550.30940.56190.0127566.0499 Mitigated 9.0 Operational Offroad Equipment TypeNumberHours/DayDays/YearHorse PowerLoad FactorFuel Type CalEEMod Version: CalEEMod.2013.2.2Date: 12/10/2014 10:03 AMPage 23 of 23 SANTA ANITA RESIDENCE PROJECT INITIAL STUDY LSA SAA1401 Appendix B: Tree Report 1 Jordan Chamberlin From:Christy Cuba <christy@cycarlberg.com> Sent:Thursday, August 20, 2015 9:09 AM To:F8GI Yahoo; Jordan Chamberlin Subject:RE: Addendum to Arborist Report, latest COA from Engineer/PW Dear Ms. Chamberlin, This email is a follow-up to our phone call of this morning. I have reviewed the updated site plans with regard to the encroachments on two oak trees and one ash tree in the northeast sections of the property at 501 Santa Anita Avenue. The encroachments do not appear to have changed significantly from the original plans addressed in our protected tree report of March 19, 2014. In my opinion, no new recommendations are necessary. Please feel welcome to contact me with any questions. Thank you. Christy Cuba Carlberg Associates 626.428.5072 www.cycarlberg.com Sent from my Android ----- Forwarded Message ----- From: Jordan Chamberlin <jchamberlin@ci.arcadia.ca.us> To: 'Scott Yang' <f8giscott@yahoo.com> Cc: Kenneth Pang <kpang@cda-arc.com> Sent: Tuesday, August 18, 2015 7:45 AM Subject: RE: Addendum to Arborist Report, latest COA from Engineer/PW Scott, I have the latest from Engineering and I am waiting on PW to finalize theirs. Regarding the letter from the Arborist, it doesn’t appear that much has changed adjacent to the tree that is to be encroached upon but it would be helpful if she addressed that as well. It could be as simple as a line or two on that, that way both the Oak Tree Removal and Oak Tree Encroachment are up to date. The additional trees she recommends and their location seem good. The landscape architect can update accordingly. Thanks. __________________________________ Jordan Chamberlin Assistant Planner|City of Arcadia 626-821-4334| JChamberlin@ArcadiaCA.gov From: Scott Yang [mailto:f8giscott@yahoo.com] Sent: Monday, August 17, 2015 11:29 PM To: Jordan Chamberlin Cc: Kenneth Pang Subject: Fw: Addendum to Arborist Report, latest COA from Engineer/PW SANTA ANITA RESIDENCE PROJECT INITIAL STUDY LSA SAA1401 Appendix C: Historical Information SANTA ANITA RESIDENCE PROJECT INITIAL STUDY LSA SAA1401 Appendix D: Train Noise Assessment December 2014 TRAIN NOISE IMPACT ANALYSIS SANTA ANITA RESIDENCES 501 NORTH SANTA ANITA AVENUE CITY OF ARCADIA, CALIFORNIA December 2014 TRAIN NOISE IMPACT ANALYSIS SANTA ANITA RESIDENCES 501 NORTH SANTA ANITA AVENUE CITY OF ARCADIA, CALIFORNIA Submitted to: City of Arcadia 240 West Huntington Drive Arcadia, California 91006 Prepared by: LSA Associates, Inc. 20 Executive Park, Suite 200 Irvine, California 92614-4731 (949) 553-0666 Project No. SAA1401 R:\SAA1401_Arcadia CE\Technical Studies\Train Noise Report 12-2014.docx «12/15/14» 1 TABLE OF CONTENTS INTRODUCTION .................................................................................................................................. 2 PROJECT LOCATION .......................................................................................................................... 2 EXISTING SETTING ............................................................................................................................ 2 PROJECT DESCRIPTION .................................................................................................................... 2 METHODOLOGY ................................................................................................................................. 2 Characteristics of Sound .................................................................................................................. 5 Measurement of Sound .................................................................................................................... 5 Physiological Effects of Noise ......................................................................................................... 6 Thresholds of Significance .............................................................................................................. 9 Overview of the Existing Noise Environment ................................................................................. 9 Sensitive Land Uses in the Project Vicinity................................................................................... 10 IMPACT ASSESSMENT .................................................................................................................... 10 Long-Term Train Noise Impacts ................................................................................................... 10 Project Design Features ................................................................................................................. 10 CONCLUSIONS .................................................................................................................................. 10 REFERENCES ..................................................................................................................................... 11 FIGURES Figure 1: Project Location Map .............................................................................................................. 3 Figure 2: Site Plan .................................................................................................................................. 4 TABLES Table A: Definitions of Acoustical Terms ............................................................................................. 7 Table B: Common Sound Levels and Their Noise Sources ................................................................... 8 R:\SAA1401_Arcadia CE\Technical Studies\Train Noise Report 12-2014.docx «12/15/14» 2 INTRODUCTION This noise impact analysis has been prepared to evaluate the potential train noise impacts and project design features needed to develop the proposed 20-unit residential complex. This report is intended to satisfy the City of Arcadia’s (City) requirement for a project-specific noise impact analysis to meet the requirements of the California Environmental Quality Act (CEQA) that examines the potential train noise impacts of the proposed uses on the project site. PROJECT LOCATION The project site is located at the northwest corner of Santa Anita Avenue and Colorado Boulevard in the City of Arcadia, as shown on Figure 1. EXISTING SETTING The existing uses on the project site include a church. The project site is bounded by existing residential uses to the north and commercial uses to the east and south. PROJECT DESCRIPTION The proposed project includes the demolition of the existing church structures and the construction of 20 dwelling units. Access to the site will be provided via full-access driveways on Cornell Drive to the west. A site plan of the project is illustrated on Figure 2. METHODOLOGY Evaluation of noise impacts associated with the proposed project includes the following:  Determine the long-term noise levels from the proposed Gold Line train noise using noise data obtained from Gold Line Phase II, Pasadena to Montclair-Foothill Extension Final Environmental Impact Report (SCH No. 200361157, February 2007), and compare the levels to the City’s pertinent noise standards.  Determine the appropriate noise abatement measures, if necessary, such as mechanical ventilation or building facade enhancements, to assure that long-term, on-site train noise impacts from all sources will be less than significant. FIGURE 1 Arcadia Multi-Family ResidentialInitial Study Regional and Project Location 01,0002,000 Feet S!!N I:\SAA1401\Reports\IS\fig1_RegLoc.mxd (12/10/2014) SOURCE: Bing Aerial, 2010 Aä ?l!"^$ %&o( !"`$ ?q A» %&l( A» !"a$ !"`$ %&l( !"^$ KË %&g( %&g( AË A¥ !"a$ !"a$ !"`$KË Pacific Ocean Los Angeles County Orange County SanBernardinoCounty RiversideCounty Regional Location Project Area 01020 Miles S!!N Project Location SANTA ANITA AVENUE COLORADO BOULEVARD Metro Railroad NEWMAN AVENUE WINDSOR ROADCORNELL DRIVE §¨¦210 Newcastle Park Residential Residential Residential Angeles National Forest Headquarters Retail Commercial CommercialResidential Commercial Commercial FIGURE 2 Arcadia Multi-Family ResidentialInitial Study Project Site 0100200 Feet S!!N I:\SAA1401\Reports\IS\fig2_Project.mxd (12/10/2014) SOURCE: Google Earth, 2014. Project Boundary R:\SAA1401_Arcadia CE\Technical Studies\Train Noise Report 12-2014.docx «12/15/14» 5 Characteristics of Sound Sound is increasing to such disagreeable levels in the environment that it can threaten quality of life. Noise is usually defined as unwanted sound. Noise consists of any sound that may produce physiological or psychological damage and/or interfere with communication, work, rest, recreation, and sleep. To the human ear, sound has two significant characteristics: pitch and loudness. Pitch is generally an annoyance, while loudness can affect the ability to hear. Pitch is the number of complete vibrations, or cycles per second, of a wave resulting in the tone’s range from high to low. Loudness is the strength of a sound that describes a noisy or quiet environment and is measured by the amplitude of the sound wave. Loudness is determined by the intensity of the sound waves combined with the reception characteristics of the human ear. Sound intensity refers to how hard the sound wave strikes an object, which in turn produces the sound’s effect. This characteristic of sound can be precisely measured with instruments. The analysis of a project defines the noise environment of the project area in terms of sound intensity and its effect on adjacent sensitive land uses. Measurement of Sound Sound intensity is measured through the A-weighted scale to correct for the relative frequency response of the human ear. That is, an A-weighted noise level de-emphasizes low and very high frequencies of sound similar to the human ear’s de-emphasis of these frequencies. Unlike linear units, such as inches or pounds, decibels are measured on a logarithmic scale representing points on a sharply rising curve. For example, 10 decibels (dB) are 10 times more intense than 1 dB, 20 dB are 100 times more intense, and 30 dB are 1,000 times more intense. Thirty decibels (30 dB) represents 1,000 times as much acoustic energy as 1 dB. The decibel scale increases as the square of the change, representing the sound pressure energy. A sound as soft as human breathing is about 10 times greater than 0 dB. The decibel system of measuring sound gives a rough connection between the physical intensity of sound and its perceived loudness to the human ear. A 10 dB increase in sound level is perceived by the human ear as only a doubling of the loudness of the sound. Ambient sounds generally range from 30 dB (very quiet) to 100 dB (very loud). Sound levels are generated from a source, and their decibel level decreases as the distance from that source increases. Sound dissipates exponentially with distance from the noise source. For a single- point source, sound levels decrease approximately 6 dB for each doubling of distance from the source. This drop-off rate is appropriate for noise generated by stationary equipment. If noise is produced by a line source, such as highway traffic or railroad operations, the sound decreases 3 dB for each doubling of distance in a hard site environment. Line source, noise in a relatively flat environment with absorptive vegetation, decreases 4.5 dB for each doubling of distance. There are many ways to rate noise for various time periods, but an appropriate rating of ambient noise affecting humans also accounts for the annoying effects of sound. Equivalent continuous sound level (Leq) is the total sound energy of time varying noise over a sample period. However, the predominant rating scales for human communities in the State of California are the Leq and Community Noise Equivalent Level (CNEL) or the day-night average level (Ldn) based on A-weighted decibels (dBA). R:\SAA1401_Arcadia CE\Technical Studies\Train Noise Report 12-2014.docx «12/15/14» 6 CNEL is the time varying noise over a 24-hour period, with a 5 dBA weighting factor applied to the hourly Leq for noises occurring from 7:00 p.m. to 10:00 p.m. (defined as relaxation hours) and 10 dBA weighting factor applied to noise occurring from 10:00 p.m. to 7:00 a.m. (defined as sleeping hours). Ldn is similar to the CNEL scale but without the adjustment for events occurring during the evening hours. CNEL and Ldn are within 1 dBA of each other and are normally exchangeable. The City uses the CNEL noise scale for long-term noise impact assessment. Other noise rating scales of importance when assessing the annoyance factor include the maximum noise level (Lmax), which is the highest exponential time averaged sound level that occurs during a stated time period. The noise environments discussed in this analysis for short-term noise impacts are specified in terms of maximum levels denoted by Lmax. Lmax reflects peak operating conditions and addresses the annoying aspects of intermittent noise. It is often used together with another noise scale, or noise standards in terms of percentile noise levels, in noise ordinances for enforcement purposes. For example, the L10 noise level represents the noise level exceeded 10 percent of the time during a stated period. The L50 noise level represents the median noise level. Half the time the noise level exceeds this level, and half the time it is less than this level. The L90 noise level represents the noise level exceeded 90 percent of the time and is considered the background noise level during a monitoring period. For a relatively constant noise source, the Leq and L50 are approximately the same. Noise impacts can be described in three categories. The first is audible impacts that refer to increases in noise levels noticeable to humans. Audible increases in noise levels generally refer to a change of 3.0 dB or greater because this level has been found to be barely perceptible in exterior environments. The second category, potentially audible, refers to a change in the noise level between 1.0 dB and 3.0 dB. This range of noise levels has been found to be noticeable only in laboratory environments. The last category is changes in noise levels of less than 1.0 dB, which are inaudible to the human ear. Only audible changes in existing ambient or background noise levels are considered potentially significant. Physiological Effects of Noise Physical damage to human hearing begins at prolonged exposure to noise levels higher than 85 dBA. Exposure to high noise levels affects the entire system, with prolonged noise exposure in excess of 75 dBA increasing body tensions, thereby affecting blood pressure and functions of the heart and the nervous system. In comparison, extended periods of noise exposure above 90 dBA would result in permanent cell damage. When the noise level reaches 120 dBA, a tickling sensation occurs in the human ear even with short-term exposure. This level of noise is called the threshold of feeling. As the sound reaches 140 dBA, the tickling sensation is replaced by the feeling of pain in the ear. This is called the threshold of pain. A sound level of 160–165 dBA will result in dizziness or loss of equilibrium. The ambient or background noise problem is widespread and generally more concentrated in urban areas than in outlying less developed areas. Table A lists definitions of acoustical terms, and Table B shows common sound levels and their sources. R:\SAA1401_Arcadia CE\Technical Studies\Train Noise Report 12-2014.docx «12/15/14» 7 Table A: Definitions of Acoustical Terms Term Definitions Decibel, dB A unit of level that denotes the ratio between two quantities that are proportional to power; the number of decibels is 10 times the logarithm (to the base 10) of this ratio. Frequency, Hz Of a function periodic in time, the number of times that the quantity repeats itself in one second (i.e., number of cycles per second). A-Weighted Sound Level, dBA The sound level obtained by use of A-weighting. The A-weighting filter deemphasizes the very low and very high frequency components of the sound in a manner similar to the frequency response of the human ear and correlates well with subjective reactions to noise. [All sound levels in this report are A-weighted, unless reported otherwise.] L01, L10, L50, L90 The fast A-weighted noise levels that are equaled or exceeded by a fluctuating sound level 1 percent, 10 percent, 50 percent, and 90 percent of a stated time period. Equivalent Continuous Noise Level, Leq The level of a steady sound that, in a stated time period and at a stated location, has the same A- weighted sound energy as the time varying sound. Community Noise Equivalent Level, CNEL The 24-hour A-weighted average sound level from midnight to midnight, obtained after the addition of 5 dBA to sound levels occurring in the evening from 7:00 p.m. to 10:00 p.m. and after the addition of 10 dBA to sound levels occurring in the night between 10:00 p.m. and 7:00 a.m. Day/Night Noise Level, Ldn The 24-hour A-weighted average sound level from midnight to midnight, obtained after the addition of 10 dBA to sound levels occurring in the night between 10:00 p.m. and 7:00 a.m. Lmax, Lmin The maximum and minimum A-weighted sound levels measured on a sound level meter, during a designated time interval, using fast time averaging. Ambient Noise Level The all-encompassing noise associated with a given environment at a specified time, usually a composite of sound from many sources at many directions, near and far; no particular sound is dominant. Intrusive The noise that intrudes over and above the existing ambient noise at a given location. The relative intrusiveness of a sound depends upon its amplitude, duration, frequency, and time of occurrence and tonal or informational content, as well as the prevailing ambient noise level. Source: Handbook of Acoustical Measurements and Noise Control (1991). R:\SAA1401_Arcadia CE\Technical Studies\Train Noise Report 12-2014.docx «12/15/14» 8 Table B: Common Sound Levels and Their Noise Sources Noise Source A-Weighted Sound Level in Decibels Noise Environments Subjective Evaluations Near Jet Engine 140 Deafening 128 times as loud Civil Defense Siren 130 Threshold of Pain 64 times as loud Hard Rock Band 120 Threshold of Feeling 32 times as loud Accelerating Motorcycle at a Few Feet Away 110 Very Loud 16 times as loud Pile Driver; Noisy Urban Street/Heavy City Traffic 100 Very Loud 8 times as loud Ambulance Siren; Food Blender 95 Very Loud Garbage Disposal 90 Very Loud 4 times as loud Freight Cars; Living Room Music 85 Loud Pneumatic Drill; Vacuum Cleaner 80 Loud 2 times as loud Busy Restaurant 75 Moderately Loud Near Freeway Auto Traffic 70 Moderately Loud Average Office 60 Quiet One-half as loud Suburban Street 55 Quiet Light Traffic; Soft Radio Music in Apartment 50 Quiet One-quarter as loud Large Transformer 45 Quiet Average Residence without Stereo Playing 40 Faint One-eighth as loud Soft Whisper 30 Faint Rustling Leaves 20 Very Faint Human Breathing 10 Very Faint Threshold of Hearing 0 Very Faint Source: Compiled by LSA Associates, Inc. (1998). R:\SAA1401_Arcadia CE\Technical Studies\Train Noise Report 12-2014.docx «12/15/14» 9 Thresholds of Significance Based on Guidelines for the Implementation of the California Environmental Quality Act (CEQA), Appendix G, Public Resource Code §15000–15387, a project will normally have a significant effect on the environment related to noise if it will substantially increase the ambient noise levels for adjoining areas or conflict with adopted environmental plans and the goals of the community in which it is located. The applicable noise standards governing the project site are the criteria in the City’s Noise Element of the General Plan and its Noise Ordinance. City of Arcadia Noise Element of the General Plan. The noise standards specified in Table N-2 of the City’s General Plan Noise Element are used as a guideline to evaluate the acceptability of the noise levels generated by the Gold Line trains and vehicular traffic in the project area. These standards are for assessment of long-term mobile sources noise impacts. The City has exterior noise criteria for outdoor living areas associated with residential uses. The City requires that interior areas of new residential homes not exceed 45 dBA CNEL and that exterior active use areas not exceed 65 dBA CNEL. Other short-term noise impacts, such as construction activities or on-site stationary sources, are regulated by the noise ordinance. Noise Ordinance. The City’s Noise Ordinance establishes the maximum permissible noise level that may intrude into a neighbor’s property. The City’s Municipal Code, Chapter 6, Noise Regulations, establishes noise level limits for various land use categories affected by stationary noise sources. For Residential Zone, the exterior noise levels shall not exceed 55 dBA for more than 30 minutes in any hour during daytime hours between 7:00 a.m. and 10:00 p.m. For events occurring within shorter periods of time, the noise levels are adjusted upward accordingly. For events lasting equal to or less than 30 minutes but more than 15 minutes, the exterior noise shall not exceed 60 dBA during daytime hours. For events lasting equal to or less than 15 minutes but more than 5 minutes, the exterior noise shall not exceed 65 dBA during daytime hours. For events lasting equal to or less than 5 minutes but more than 1 minute, the exterior noise shall not exceed 70 dBA during daytime hours. At any time during daytime hours, the exterior noise shall not exceed 75 dBA. During the nighttime hours between 10:00 p.m. and 7:00 a.m. the following day, the above noise standard levels are reduced by 5 dBA. At the boundary line between two different zones, the noise level of the quieter zone shall be used. The City’s Municipal Code noise ordinance has not established any upper limits for construction noise because it is temporary and will cease to occur after completion of the project construction. Overview of the Existing Train Noise Environment Train noise on the railroad tracks to the southwest of the project site, including the Gold Line commuter trains, contribute to the ambient noise in the project area. R:\SAA1401_Arcadia CE\Technical Studies\Train Noise Report 12-2014.docx «12/15/14» 10 Sensitive Land Uses in the Project Vicinity The project site is bounded by existing residential uses to the north and commercial uses to the east and south. IMPACT ASSESSMENT Long-Term Train Noise Impacts Based on noise data obtained from Gold Line Phase II, Pasadena to Montclair–Foothill Extension Final Environmental Impact Report (SCH No. 200361157, February 2007), it was shown that existing measured noise level was 73 dBA Leq. However, the projected noise level from the operation of the Gold Line trains was projected to be 49 dBA Leq. Therefore, the projected train noise was much lower than existing ambient noise, including contribution from vehicular traffic, and would not significantly affect the project site. Even if it is assumed that this projected hourly noise level would last over 24 hours, the 24-hour weighted average noise from train operations would be 55.7 dBA CNEL. Just by train noise alone, it would not exceed the City’s exterior noise standard of 65 dBA CNEL for residential uses. Based on the United States Environmental Protection Agency’s (EPA) Protective Noise Levels (EPA 550/9-79-100, November 1978), with a combination of exterior walls, doors, and windows, standard construction for Southern California (warm climate) commercial or residential buildings would provide more than 24 dBA in exterior to interior noise reduction with windows closed and 12 dBA or more with windows open (national average is 25 dBA with windows closed and 15 dBA with windows open). With windows or doors open, interior noise levels at these buildings would be below 45 dBA (i.e., 56 dBA - 12 dBA = 44 dBA). With windows closed, interior noise levels would also be lower than the 45 dBA (56 dBA - 24 dBA = 32 dBA). This range of maximum train noise exposure levels is below the City’s 45 dBA CNEL interior noise level for the noise- sensitive residential uses. Therefore, no specific noise design features are required for train noise alone. Project Design Features Train Noise Impacts. No specific project design features are required. CONCLUSIONS Train noise impacts on the proposed project will not exceed CEQA significance thresholds and no specific Project Design Features are required for train noise impacts. R:\SAA1401_Arcadia CE\Technical Studies\Train Noise Report 12-2014.docx «12/15/14» 11 REFERENCES City of Arcadia. Noise Element of the General Plan and Municipal Code Noise Ordinances. Gold Line Phase II, Pasadena to Montclair – Foothill Extension, Final Environmental Impact Report, SCH No. 200361157, February 2007. United States Environmental Protection Agency. 1978. Protective Noise Levels, condensed version of EPA Levels Document, EPA 550/9-79-100. November. Attachment No. 8 Attachment No. 8 Preliminary Exemption Assessment Preliminary Exemption Assessment FORM “A” PRELIMINARY EXEMPTION ASSESSMENT (Certificate of Determination When Attached to Notice of Exemption) 1. Name or description of project: Modification Application No. MP 16-04, revisions to the previously approved Multiple-Family Architectural Design Review No. MFADR 14-09, and extension requests for the previously approved Zone Variance No. ZV 15-02, Modification No. MP 14- 17, And Oak Tree Encroachment Permit No. TRE 14-30 for a 20- unit, two-story, Contemporary-style, townhouse condominium development project 2. Project Location – Identify street address and cross streets or attach a map showing project site (preferably a USGS 15’ or 7 1/2’ topographical map identified by quadrangle name): 501 N. Santa Anita Avenue (cross streets: N. Santa Anita Avenue and Colorado Boulevard) 3. Entity or person undertaking project: A. DC Santa Anita Holdings, LLC B. Other (Private) (1) Name (2) Address 1005 E. Las Tunas Drive, #125 San Gabriel, CA 91776 4. Staff Determination: The Lead Agency’s Staff, having undertaken and completed a preliminary review of this project in accordance with the Lead Agency's "Local Guidelines for Implementing the California Environmental Quality Act (CEQA)" has concluded that this project does not require further environmental assessment because: a. The proposed action does not constitute a project under CEQA. b. The project is a Ministerial Project. c. The project is an Emergency Project. d. The project constitutes a feasibility or planning study. e. The project is categorically exempt. Applicable Exemption Class: Class 32 15332 In-Fill Development f. The project is statutorily exempt. Applicable Exemption: g. The project is otherwise exempt on the following basis: h. The project involves another public agency which constitutes the Lead Agency. Name of Lead Agency: Date: March 31, 2016 Staff: Jordan Chamberlin, Assistant Planner