Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
Untitled
"` Development Services Department 240 West Huntington Drive,Post Office Box(7x,921 PERMIT NO. ,�% , 'Ac, - /4 -2-�� - - : 0-13 -oC3•-33 V NOTES Building Inspections Date Insp. Plumbing Inspections I Date I Insp. 100. Setbacks 210. Under ft./bldg.drain 44. ..- 7- 101. Rough grade 211. Copper underslab ����6, 7- ^��� 102. Fi•s.&forms 12. Roush•lumbin• -l9/G /�A tger ,s;s7-,�e, e� • • {,L vc-T5 vs' 103. Pre-slab 213. Rough gas 1%43 Nil 104. Floor joists 214. Shower pan ='4 2:4‘ Z 4A/ F.46 14-S r, 105. Steel 215. Water heater ::- --/ Mil 106. Grout lift 216. Roof drains 107. Shear nailing 217. Building sewer 108. Dia•h nailin• 218. Water service 109. Roof nailin. -MP=219. Final.as m19� 110. Framin• /riff. 220. Fixtures -OPINI� 111. 0cc./Area Seat.Wall -�221. Final•lumbin• �'�jr � 112. Sound walls --222. Sewer cap/demo. -� 113. T•bar•rid 114. Insulation-Flr. Pool Inspections Date Insp. 115. Insulation-Wall 240. Excavation/steel 116. Insulation-Ceil. 241. Rough plumbing 117. Drywall nailing 1 NI 242. Light shell/bonding 118. Interior lath 243. Underground conduit 119. Exterior lath 244. P-trap 120. Finish•rade 245. Gas line&test 121. Final building 246. Fence,gates&signs 122. Final demo/lot clear 247. Pool heater 248. Final electric Electrical Inspections Date Insp. 249. Final plumbing 150. Power•.le 250. Pool cover 151. Sales lot lighting 251. Pool final 152. Under•round conduit 153. Underslab conduit -_ Reroof Inspections I Date I Insp. 154. UFER ground 270. Pre-reroof insp. 155. Water ground 71. Roof framing 156. Rough electrical _ /272. Sheathing nailing 157. Fixtures 273. Final reroof 158. G.F.C.I. 159. E..t.bondin• :� r• Sign Inspections I Date I Insp. 160. Service panel % -`G , 280. Setback/overhang 161. Final electric :-'/ raa 281. Footing 282. Conduit/wirin• Mechanical Inspections Date Insp. 283. Disconnect 180. Furnace/A.C. e/A. -�284. Final sign 181. Furnace(A.C. 182. Rouch HVAC $-1 - Fr Miscellaneous Insp. I Date I Insp. 183. Fire dampers 290. Fire alarm 184. Furnace compartment 291. Underground supply 185. Combustion air 292. Fire sprinklers 186. Smoke detectors 293. Monitor system 187. Metal F.P.rough 294. Hood dry chem. 188. Compressor setback 295. Final 189. Commercial hood - Y6 IiAO Alli 190. Duct shaft -ME Sewers&Offsite Insp. I Date I Insp. 191. Final mechanical Z. OM 300. Lateral(main to P/L) 301. Saddle/Y Block Wall Inspections Date Insp. 302. Cesspool filled 200. Footings 303. Sidewalk 201. Steel/rebar 304. Driveway 202. Grout lift 305. Curb replacement 203. Final wall 306. Trash bin 1t 11 _. tltl t l 4111_1, Am ±. ttal 11�f ))1 '11.kv sai t7 .� 0 O `0 C Co a ) o e f -a B n a cn, 0,14 g! 5 Pu ' '' ..-) # tie O c a c ,_,..; k ifti ( ,....1, co .0 11 C. 5" is: a 0 0 CD a 0 'a a 5 �_ D . � � a y v�q m Z 5 •c . ••••• v 4 ..4 .0 ‘...1.161.-'/,. .).... n g p A 4 ,.., cz ill . 01 ' N W • E a to rr• r t ' e .. E, n W =•R w E. 0 CI ■ ' C g O E. ` J .• G P o [i7 I w bv . 4 :::-,,1 .r n 0 VIPQ 4 7:, E ) 1 r _ .. iie, IV .•••=6"". , ,_ ,,,*ii_w w w , . _ . w, ___ .160 w la , :). /►J 11 It 11 i' it t1 4 t tl 4• Lit" ` i,,A< °' Development Services Department 240 West Huntington Drive,Post Office Box 60021 PERMIT NO BOO-054-180 Arcadia, CA 91066-6021 City of (626) 574-5416,Fax(626)447-9173 Arcadia Type:Permit T e EMP Combo PROJECT TRACT NO. LOT NO. APPLICATION DATE ISSUED BY PRINT DATE PERMIT STATUS 7/7/2016 CM 13:12 7/7/2016 Issued ADDRESS NO. Dir.Prefix Street Name Street Suffix UNIT BLG ASSESSORS PARCEL NO. GEO CODE 400 S Baldwin Ave T-387 OWNER MAILING ADDRESS Westfield Corporation, Inc. 11601 Wilshire Blvd. 12th Floor PHONE NO. Los Angeles, CA 90025- EMAIL ADDRESS: APPLICANT MAILING ADDRESS I [sao Kim 9� EMAIL ADDRESS: CONTRACTOR/PROFESSIONAL MAILING ADDRESS (213 NO. 220-6677 FAX NO. Isao Kim 3028 Honolulu Ave PHONE La Crescenta, CA 91214 EMAIL ADDRESS: License No. 912989 Type: B,C10,C36 Expires: 3/31/2018 12:00: TENANT MAILING ADDRESS PHONE NO. FAX NO. DESCRIPTION FMP FOR TSURUMARU UDON,T1 Construction Type UOM ft of Units Value Construction Type UOM #of Units Value �.I4-c. 1 -1 -/G /.42(.... ---;..,,,,,---- OCCUPANCY: TOTAL VALUATION: $0.00 QTY UOM DESC AMT AMT PAID ACCT QTY UOM DESC AMT AMT PAID ACCT 1.00 flat Flee issue 44.35 44.35 01-3105 1.00 Flat SWMF 2 1.00 1.00 88-3027 1.00 Flat Mech issue 44.35 44.35 01-3105 1.00 Flat Plmbg issuance 44.35 44.35 01-3105 1,00 each Comm svc<200 a 31,43 31.43 01-3105 2.00 each Furn<100,000btu 37.48 37.48 01-3105 3.00 each Hood 42.33 42.33 01-3105 6.00 each Kitchen sinks 74.76 74.76 01-3105 1.00 each Distrib panel 15.55 15.55 01-3105 4.00 each Floor sink 49.84 49.84 01-3105 2 00 each Comp 3-15hp 68.58 68.58 01-3105 4 00 each Floor drain 49.84 49.84 01-3105 10.00 outlets Gas piping 31.00 31.00 01-3105 10.00 each Outlets 15.40 15.40 01-3105 24.00 each Ltgfixtures 32,00 32.00 01-3105 1.00 each Wtrhtr/vent 15,55 15.55 01-3105 1.00 Flat SWMF 2 1.00 1.00 88-3027 1.00 Flat SWMF 2 1.00 1.00 88-3027 Total Fees: $599.81 Balance Due: $0.00 Paid Today: $599.81 This permit/plan review expires by time limitation and becomes null and void if the work authorized by the 'eceipt r: 5' permit is not commenced within 180 days from the date of issuance or if the permit is not obtained within 180 days from 01-3105 596.81 the date of plan submittal.This permit expires and becomes null and void if any work authorized by this permit 88-3027 3.00 is suspended or abandoned for 180 consecutive days or if no progressive work has been verified by a City of Arcadia building inspector for a period of 180 consecutive days. CALLS FOR INSPECTION INSPECTORS'OFFICE HOURS if Requests for inspection should be made at least Monday-Thursday Friday one(1)business day in advance of the inspection 7:30 a.m.to 8:30 a.m. 7:30 a.m.to 8:30 a.m. ' by telephone at(626)574-5416 for onsite work. 4:00 p.m.to 5:30 p.m. 4:00 p.m.to 4:30 p.m. (Closed on alternate Fridays) ,* '* Development Services Department yid r� 240 West Huntington Drive, Post Office Box 60021 PERMIT NO. "'` Arcadia, Ca 91066-6021 BOO-054-086 City of (626) 574-5416, Fax(626)447-9173 Arcadia Permit Type: Fire PROJECT TRACT NO. LOT NO. APPLICATION DATE ISSUED BY PRINT DATE PERMIT STATUS 6/28/2016 CM 11:20 7/26/2016 Issued ADDRESS NO. Dir.Prefix Street Name Street Suffix UNIT BLG ASSESSORS PARCEL NO. GEO CODE 400 S Baldwin Ave T-387 OWNER MAILING ADDRESS Westfield Corporation, Inc. •or. A 0 Floor PHONE NO. Inspector#: FIRE EMAIL ADDRESS: Plan Chk#: 16-294 APPLICANT MAILING ADDRESS Paraclete Fire& Safety, Inc. PHONE NO. EMAIL ADDRESS: CONTRACTOR/PROFESSIONAL MAILING ADDRESS Paraclete Fire& Safety, Inc. 2950 Saturn Unit I PHONE NO. (714)577-5779 FAX NO. Brea,CA 92821 EMAIL ADDRESS: License No. 854489 Type: C-16 Expires: 10/31/2017 12:01 TENANT MAILING ADDRESS Tsurumaru Udon PHONE NO. FAX NO. DESCRIPTION NEW HOOD SYSTEM FOR NEW RESTAURANT Construction Type UOM #of Units Value Construction Type UOM #of Units Value Value Value 1,900.00 $1,900.00 F;/•frdc- cj-6 LC /7471..../"---. .. OCCUPANCY: Fire Sprink/AIm TOTAL VALUATION: $1,900.00 QTY UOM DESC AMT AMT PAID ACCT QTY UOM DESC AMT AMT PAID ACCT 12.00 each Fire Ext.Sys. 765.00 765.00 01-3109 1.00 Flat Fire Issue Auto 44.35 44.35 01-3112 each Fire Permit 99.45 99.45 01-3112 1.00 each SWMF 2 Auto 1.00 1.00 88-3027 Total Fees: $909.80 Balance Due: $0.00 Paid Today: $144.80 This permit/plan review expires by time limitation and becomes null and void if the work authorized by the Receipt#: 113739 permit is not commenced within 180 days from the date of issuance or if the permit is not obtained within 180 days from 01-3112 143.80 the date of plan submittal.This permit expires and becomes null and void if any work authorized by this permit 88-3027 1.00 is suspended or abandoned for 180 consecutive days or if no progressive work has been verified by a City of Arcadia building inspector for a period of 180 consecutive days. CALLS FOR INSPECTION INSPECTORS'OFFICE HOURS Requests for inspection should be made at least Monday-Thursday Friday one(1)business day in advance of the inspection 7:30 a.m.to 8:30 a.m. 7:30 a.m.to 8:30 a.m. by telephone at(626)574-5416 for onsite work. 4:00 p.m.to 5:30 p.m. 4:00 p.m.to 4:30 p.m. (Closed on alternate Fridays) e ' Development Services Department .' ' 240 West Huntington Drive, Post Office Box 60021 $QQ-054-124 J PERMIT NO. Arcadia,CA 91066-6021 City of (626) 574-5416 Fax(626)447-9173 Arcadia Permit Type: Fire PROJECT TRACT NO. LOT NO. APPLICATION DATE ISSUED BY PRINT DATE PERMIT STATUS 6/30/2016 CM 16:32 7/21/2016 Issued ADDRESS NO. Dir.Prefix Street Name Street Suffix UNIT BLG ASSESSORS PARCEL NO. GEO CODE 400 S Baldwin Ave T-387 OWNER MAILING ADDRESS Westfield Corporation, Inc. 11601 Wilshire Blvd. 12th Floor PHONE NO. Plan Chk#: 16-304 Los Angeles,CA 90025- EMAIL ADDRESS: APPLICANT MAILING ADDRE pa,Building Electronic Con'o s r PHONE NO.t n EMAIL ADDRESS: CONTRACTOR/PROFESSIONAL MAILING ADDRESS Building Electronic Controls Inc. 2246 Lindsay Way PHONE NO. FAX NO. Glendora,CA 91740 EMAIL ADDRESS: License No. 729905 Type: C Expires: 11/30/2016 12:0( TENANT MAILING ADDRESS PHONE NO. FAX NO. DESCRIPTION NEW FIRE ALARM-7 DEVICES ¶st4 le U Yh 141e k L&d t^0 Construction Type UOM #of Units Value Construction Type UOM #of Units Value Value Value 6,600.00 $6,600.00 OCCUPANCY: Fire Sprink/Alm TOTAL VALUATION: $6,600.00 QTY UOM DESC AMT AMT PAID ACCT QTY UOM DESC AMT AMT PAID ACCT 7.00 each fire alarm pc 2 637.50 637.50 01-3109 1.00 Flat Fire Issue Auto 44.35 44.35 01-3112 each Fire Permit 187.15 187.15 01-3112 1.00 each SWMF 2 Auto 1.00 1.00 88-3027 Total Fees: $870.00 Balance Due: $0.00 Paid Today: $232.50 This permit/plan review expires by time limitation and becomes null and void if the work authorized by the Receipt#: 113685 permit is not commenced within 180 days from the date of issuance or if the permit is not obtained within 180 days from 01-3112 231.50 the date of plan submittal.This permit expires and becomes null and void if any work authorized by this permit 88-3027 1.00 is suspended or abandoned for 180 consecutive days or if no progressive work has been verified by a City of Arcadia building inspector for a period of 180 consecutive days. CALLS FOR INSPECTION INSPECTORS'OFFICE HOURS (1) Requests for inspection should be made at least Monday Thursday Friday one(1)business day in advance of the inspection 7:30 a.m.to 8:30 a.m. 7:30 a.m.to 8:30 a.m. / by telephone at(626)574-5416 for onsite work. 4:00 p.m.to 5:30 p.m. 4:00 p.m.to 4:30 p.m. (Closed on alternate Fridays) Development Services Department r 240 West Huntington Drive,Post Office Box 60021 '��"`„-' Arcadia, CA 91066-6021 PERMIT NO BOO-054-113 City of (626) 574-5416,Fax(626)447-9173 Arcadia Permit Type: Fire PROJECT TRACT NO. LOT NO. APPLICATION DATE ISSUED BY PRINT DATE PERMIT STATUS 6/29/2016 CM 16:09 8/8/2016 Issued ADDRESS NO. Dir.Prefix Street Name Street Suffix UNIT BLG ASSESSORS PARCEL NO. GEO CODE 400 S Baldwin Ave T-387 OWNER MAIUNG ADDRESS Westfield Corporation, Inc. 11601 Wilshire Blvd. 12th Floor PHONE NO. Plan Chk#: 16-301 Los Angelejjjjs,,CA 90025- EMAIL ADDRESS: , APPLICANT M•LIN RES T E 0 Allready Fire Sprinkler Co. i PHONE NO. EMAIL ADDRESS: , CONTRACTOR/PROFESSIONAL MAILING ADDRESS Allready Fire Sprinkler Co. 818 N Grand Av PHONE NO. (626)913-6720 FAX NO. Covina, CA 91723 EMAIL ADDRESS: License No. 358795 Type: C16 Expires: 7/31/2016 12:00: TENANT MAILING ADDRESS Tsurumaru Udon PHONE NO. FAX NO. DESCRIPTION FIRE SPRINKS 10 HEADS Construction Type UOM #of Units Value Construction Type UOM #of Units Value Value Value 3,250.00 $3,250.00 OCCUPANCY: Fire Sprink/Alm TOTAL VALUATION: $3,250.00 QTY UOM DESC AMT AMT PAID ACCT QTY UOM DESC AMT AMT PAID ACCT 10.00 each sprinklerpck 255.00 255.00 01-3109 1.00 Flat Fire Issue Auto 44.35 44.35 01-3112 each Fire Permit 137.05 137.05 01-3112 1.00 each SWMF 2 Auto 1.00 1.00 88-3027 Total Fees: $437.40 Balance Due: $0.00 Paid Today: $182.40 This permit/plan review expires by time limitation and becomes null and void if the work authorized by the Receipt#: 113879 permit is not commenced within 180 days from the date of issuance or if the permit is not obtained within 180 days from 01-3112 181.40 the date of plan submittal.This permit expires and becomes null and void if any work authorized by this permit 88-3027 1.00 is suspended or abandoned for 180 consecutive days or if no progressive work has been verified by a City of Arcadia building inspector for a period of 180 consecutive days. CALLS FOR INSPECTION INSPEC"f ORS'OFFICE HOURS Requests for inspection should be made at least Monday-Thursday Friday one(1)business day in advance of the inspection 7:30 a.m.to 8:30 a.m. 7:30 a.m.to 8:30 a.m. by telephone at(626)574-5416 for onsite work. 4:00 p.m.to 5:30 p.m. 4:00 p.m.to 4:30 p.m. (Closed on alternate Fridays) 16 V A ORIN 40 ilC.:;6 ;11111671.1A k Mp.t 5.1707 c0\ ip� �aaityoi�� MEMORANDUM Fire Department DATE: September 1, 2016 TO: BUILDING DEPARTMENT INSPECTOR Henry Kemick FROM: FIRE DEPARTMENT SUBJECT: FIELD INSPECTION ADDRESS: 400 S. Baldwin Avenue #M20 (Tsurumaru Udon) THE FOLLOWING ITEMS WERE CHECKED FOR CONFORMANCE WITH APPLICABLE FIRE DEPARTMENT REQUIREMENTS: . TYPE OF INSPECTION DATE / INITIAL FINAL INSPECTION FIRE SPRINKLERS 8-31-2016 Jill Perumean FIRE ALARMS 8-31-2016 Jill Perumean TANKS HOOD & DUCT KNOX BOX OCCUPANCY 8-31-2016 Jill Perumean COMMENTS: Emailed Bldg. Dept. 9-1-2016 jp „,o COUNTY OF LOS ANGELES• DEPARTMENT OF PUBLIC HEALTH ce-”( ENVIRONMENTAL HEALTH !+ BUREAU OF SPECIALIZED SURVEILLANCE AND ENFORCEMENT } PLAN CHECK PROGRAM-BALDWIN PARK y �. CdiMr Of LOS AraeuS %roM�■ 5050 COMMERCE DR,BALDWIN PARK,CA 91706 Public N/anh PHONE:(626)430-5560 WWW.PUBLICHEALTH.LACOUNTY.GOV/EH PLAN CHECK OFFICIAL INSPECTION REPORT DATE 09/01/2016 EHS 1 JESS BARRIOS PLAN CHECK NUMBER SR0067763 PROGRAM ELEMENT 1772-EXPEDITED- RESTAURANT(501-1999 SF) OWNER I REQUESTER RYAN O'NAN,AGENT DBA TSURUMARU UDON ADDRESS 400 S BALDWIN AVE 231,ARCADIA, CA 91007 FINAL REINSPECTION STATUS: APPROVED CORRECTION CATEGORY DATE IDENTIFIED DATE CORRECTED FLOOR BASE COVING 08/30/2016 08/31/2016 WALLS 08/30/2016 08/31/2016 CEILINGS 08/30/2016 08/31/2016 WAREWASHING FACILITIES 08/30/2016 08/31/2016 FOOD PREPARATION SINKS 08/30/2016 08/31/2016 HANDWASHING FACILITIES 08/30/2016 08/31/2016 JANITORIAL FACILITIES 08/30/2016 08/31/2016 WATER SUPPLY 08/30/2016 08/31/2016 WASTE WATER/PLUMBING 08/30/2016 08/31/2016 EQUIPMENT/STORAGE 08/30/2016 08/31/2016 VERMIN EXCLUSION/ENCLOSURE 08/30/2016 08/31/2016 PLAN SUBMITTAUREMODEL 08/30/2016 08/31/2016 PLAN SUBMITTAUREMODEL 08/31/2016 09/01/2016 SCOPE OF OPERATION APPROVED TO STOCK PREPACKAGED/NON-POTENTIALLY HAZARDOUS FOODS APPROVED TO STOCK PERISHABLE/POTENTIALLY HAZARDOUS FOODS APPROVED FOR FOOD PREPARATION APPROVED TO USE MULTISERVICE UTENSILS Help us serve you better by completing a short survey.Visit our website at www.oublichealth.lacountv.aov/eh. EHS Signature Page 1 of 3 PLAN CHECK OFFICIAL INSPECTION REPORT DATE 09/01/2016 EHS I JESS BARRIOS PLAN CHECK NUMBER SR0067763 PROGRAM ELEMENT 1772-EXPEDITED- RESTAURANT(501-1999 SF) OWNER I REQUESTER RYAN O'NAN,AGENT DBA TSURUMARU UDON ADDRESS 400 S BALDWIN AVE 231,ARCADIA, CA 91007 ADDITIONAL REQUIREMENTS APPROVED TO OPERATE. COMMENTS APPROVED TO OPERATE. Help us serve you better by completing a short survey.Visit our website at www.publichealth.lacountv.aov/eh. EHS Signature Page 2 of 3 PLAN CHECK OFFICIAL INSPECTION REPORT DATE 09/01/2016 EHS I JESS BARRIOS PLAN CHECK NUMBER SR0067763 PROGRAM ELEMENT 1772-EXPEDITED- RESTAURANT(501-1999 SF) OWNER/REQUESTER RYAN O'NAN,AGENT DBA TSURUMARU UDON ADDRESS 400 S BALDWIN AVE 231,ARCADIA, CA 91007 DISCLOSURES It is a misdemeanor violation to begin operation without a valid Public Health Permit/License.The Public Health Permit/License will be issued by the Los Angeles County Department of Public Health Environmental Health Division(DPH-EH) Plan Check Program at the job site following final inspection and approval by all applicable agencies. Remodeled areas of an existing food facility/establishment must obtain a final inspection and approval from all applicable enforcement agencies prior to use. Any future alteration,construction,building,renovation,repair,change of equipment,change of the operation of a food facility/establishment or change of menu may require plans to be submitted to the DPH-EH Plan Check Program. Additional approvals may be required from other enforcement agencies. It is improper and illegal for any County officer,employee or inspector to solicit bribes,gifts or gratuities in connection with performing their official duties. Improper solicitations include requests for anything of value such as cash,discounts,free services,paid travel or entertainment,or tangible items such as food or beverages. Any attempt by a County employee to solicit bribes,gifts or gratuities for any reason should be reported immediately to either the County manager responsible for supervising the employee or the Fraud Hotline at(800)544-6861 or www.lacountyfraud.org. YOU MAY REMAIN ANONYMOUS Public Health Permit/License: A separate fee is required for the Public Health Permit/License.A billing statement will be sent to the permit/license holder annually by the DPH-EH. The fee is required to be paid to perform or carry on,conduct or engage in any mobile food facility listed in Los Angeles County Code,Title 8,Section 8.04.720. State and Local Licenses and Permits: Contact the State of California and your local city hall regarding additional license and permit requirements. Restrooms: Customer may use restroom facilities if they are located in a customer area.Customers may not enter the food preparation area,food storage area,or the utensils washing/storage areas in order to access the restrooms.All food,utensils and equipment must be protected from contamination. Routine Inspection:The DPH-EH conducts routine inspections of all food facilities in Los Angeles County. Following the issuance of your Public Health Permit by the Plan Check Program,an Environmental Health Specialist from your local district will conduct an inspection of your facility. If your Business is located in a city that has adopted the grading ordinance,the inspector will post a grade or score card at your facility. Grade/Score cards are not issued by the Plan Check Program. Help us serve you better by completing a short survey.Visit our website at www.publichealth.lacountv.00v/eh. •--_.rte EHS Signature Page 3 of 3 Test and Balance Report FOR Tsurumaru Udon @ City of Arcadia 400 S.Baldwin Ave. Arcadia, CA 91007 General Contractor Gary Kanda+Associates 8151 Blewett Street Rosemead, CA 91770 C 323.637.4070/C 626.548.9855 Iuistorres10(cr�.aol.com/shiniitanabe357C@gmail.com The testing/adjusting/balancing of the air conditioning and commercial kitchen ventilation systems has been conducted in accordance with manufacturer's instructions and the National Environmental Balancing Bureau (NEBB)Procedural Standards for Testing,Adjusting and Balancing of Environmental Systems. Certified by Young S.Shin,PE C? C0/7 NEBB Certified TAB Professional -r s - =I YCIN G S.SHIN GBS COMPANY CERTIFICATE co 9� 3108 900 S.Westmoreland Avenue,Suite 311 w, �0F Los Angeles,CA 90006 'a 'clrorslog4g Tel(213)389-3982 Fax(213)389-5146 August 31,2016 T16078 Tsurumaru Udon @ City of Arcadia 1/12 us GDf Company est A PROJECT INFORMATION PROJECT: Tsurumaru Udon @ City of Arcadia LOCATION: 6316 Figueroa Street,Los Angeles,CA 90042 B Air Conditioning System 1 (E)VAV-1:Existing single duct variable air volume terminal air unit(SDVAV)of pressure independent,electronic control actuator.Electronic room thermostat controls operation of the VAV unit. C Kitchen Ventilation System 1 KH-1:Llisted type 1 canopy hood is used to capture and exhaust grease laden air,heat,vapor and odors generated from cooking appliances under the hood. 2 KH-2:Llisted type 1 canopy hood is used to capture and exhaust grease laden air,heat,vapor and odors generated from cooking appliances under the hood. 3 KEF-1:A roof mount upblast centrifugal exhaust fan removes grease laiden air from KH-1.The system is operated by a wall mount common toggle switch(S1).KEF-1 is electrically interlocked with MUA-I. 4 KEF-2:A roof mount upblast centrifugal exhaust fan removes grease laiden air from KH-2.The system is operated by a wall mount toggle switch(S1).KEF-2 is electrically interlocked with MUA-I. 5 MAU-1:The roof mount filtered supply fan with down discharge provides makeup air for KH-1 and KH-2. D TAB Work 1 Testing/adjusting/balacing work for the systems was performed on August 29,2016. 2 Airflow rates for the systems were balanced within acceptable ranges. T16078 Tsurumaru Udon @ City of Arcadia 2/12 GU tt AIR TERMINAL UNIT-SD VAV CBI PROJECT Tsurumaru Udon @ City of Arcadia DATE August 29,2016 LOCATION: 400 S.Baldwin Ave.,Arcadia, CA 91007 BY IS/YS Unit Data Type Make Model Control HW Control Valve Make Model A Single Duct VAV Titus EESV Electronic NA NA NA Test Data Item Size In. Cooling Air Flow,CFM Heating Air Flow,CFM No. System/Unit Service Type dia. Design Actual %Des. Design Actual %Des. Max Min Max Min Max Min VAV-1 See Plan. A 8 650 NS 680 210 105 NA NA NA NA Remarks: T16078 Tsurumaru Udon @ City of Arcadia 3/12 611f AIR OUTLET/INLET-SD VAV Gill Company @nt PROJECT Tsurumaru Udon @ City of Arcadia DATE August 29,2016 LOCATION: 400 S.Baldwin Ave.,Arcadia, CA 91007 BY IS/YS Device Data Type CD1 Ceiling Diffuser CD2 Ceiling Diffuser,Round Test Data Item Size In. Cooling Air Flow,CFM Heating Air Flow,CFM No. System/Unit Service Type dia. Design Actual %Des. Design Actual %Des. Max Min Max Min Max Min S1 VAV-1 See Plan. CD1 8 300 NS 320 130 107 NA NA NA NA S2 VAV-1 See Plan. CD1 8 350 NS 360 145 103 NA NA NA NA S3 PAC Dining Area CD2 12 700 NA 680 NA 97 NA NA NA NA Remarks: T16078 Tsurumaru Udon©City of Arcadia 4/12 GB! AIR OUTLET I INLET CBI GUS Company TEST REPORT PROJECT Tsurumaru Udon @ City of Arcadia DATE August 29,2016 LOCATION: 400 S.Baldwin Ave.,Arcadia, CA 91007 BY IS/YS Device Data Type D Perforated Supply Plenum,156"L x 14"width x 6"Height total Test Data Service Duct Size Air Flow,cfm Item No. System/Unit Type — — — Name in.dia Design Actual %Des MA1 MUA-1 KH-1 D 24x12 1530 _ 1545 101 MA2 MUA-1 KH-1 D 24x12 1530 1627 106 MA3 MUA-1 KH-1 D 24x12 1530 1640 107 Total 4590 4812 105 Remarks: T16078 Tsurumaru Udon @ City of Arcadia 5/12 `u OBI GBS Company KITCHEN HOOD PROJECT: Tsurumaru Udon @ City of Arcadia DATE August 29,2016 LOCATION: 400 S.Baldwin Ave.,Arcadia, CA 91007 BY IS/YS TYPE 1 KITCHEN HOOD TEST REPORT I TYPE 1 KH Hood Data Grease Filter Data Hood No KH-1 Size:L x W x H 12'x 54"x 24" Type Baffle Location Kitchen Available Length, in. 144 Construction Stainless Steel Job No. 2677589 Exposed Sides 3 Size,in.(HxW) (9)20 x 16 x 2 Type Listed Type 1 Airflow:CFM 2400 Free Area,(ft2) 1.78 Make/Model CaptiveAire/5424ND-2 Serving Fan KEF-1 Make/Model Captrate Solo Filter Other Data Grease Duct Size,in. 12 x 18 Grease Duct Area,ft2 1.50 Hood Lower Lip to Floor,in. 80 Distance Between Lower Lip of Hood and Cooking Surfaces,in. 48 Appliances Under Hood: (4)stock pot ranges; griddle'4-burner range;fryer;rice cooker Test Data Item Design Actual %Design Airflow,Q,CFM _ 2,400 2,612 109% Veloctiy Readings Across Grease Filters,V,fpm Filter Number POINTS #1 #2 #3 #4 #5 Total 1 2 3 1 2 3 1 2 3 1 2 3 1 2 3 1 129 121 126 139 128 134 140 177 186 212 189 185 205 214 200 2 131 167 134 129 138 141 149 178 191 198 189 174 211 207 215 3 126 130 122 135 127 132 143 184 201 189 202 185 204 216 203 Vav=Vsum/9 132 134 172 191 208 Free Area 1.78 1.78 1.78 1.78 1.78 Filter CFM 235 238 306 341 371 1490 Filter Number POINTS #6 #7 #8 #9 Total 1 2 3 1 2 3 1 2 3 1 2 3 1 208 197 185 136 156 186 155 127 125 129 138 141 2 188 178 171 149 167 198 148 137 140 131 141 146 3 198 189 191 143 178 182 155 126 136 135 127 132 Vav=Vsum/9 189 166 139 136 Free Area _ 1.78 1.78 1.78 _ 1.78 Filter CFM 337 296 247 241 1121 Remarks: 2750 T16078 Tsurumaru Udon @ City of Arcadia 6/12 6u GB$ Oempony KITCHEN HOOD CBI PROJECT: Tsurumaru Udon @ City of Arcadia _ DATE August 29,2016 LOCATION: 400 S.Baldwin Ave.,Arcadia, CA 91007 _ BY IS/YS TYPE 1 KITCHEN HOOD TEST REPORT I TYPE 1 KH Hood Data Grease Filter Data Hood No KH-2 Size:L x W x H 9'9"x 54"x 24" Type Baffle Location Kitchen Available Length, in. 117 Construction Stainless Steel Job No. 2677589 Exposed Sides 3 Size,in.(HxW) (7)20 x 16 x 2 Type Listed Type 1 Airflow:CFM 2700 Free Area,(ft2) 1.78 Make/Model CaptiveAire/5424ND-2WI Serving Fan KEF-1 _Make/Model Captrate Solo Filter Other Data Grease Duct Size,in. 12 x 18 Grease Duct Area,ft2 1.50 Hood Lower Lip to Floor,in. _ 78 Distance Between Lower Lip of Hood and Cooking Surfaces,in. 44 Appliances Under Hood: pasta cooker; 2-compartment sink, pasta cooker Test Data Item Design Actual %Design Airflow,Q,CFM 2,700 2,641 98% Veloctiy Readings Across Grease Filters,V,fpm Filter Number POINTS #1 #2 #3 #4 #5 1 Total 1 2 3 1 2 3 1 2 3 1 2 3 1 2 3 1 180 204 199 190 201 188 211 205 199 230 227 231 250 241 245 2 166 171 163 179 185 178 209 222 208 240 233 229 245 239 233 3 192 189 201 199 202 192 202 189 201 219 224 225 248 241 251 Vav=V sum/9 185 190 205 229 244 Free Area 1.78 1.78 1.78 1.78 1.78 Filter CFM 329 339 365 407 434 1874 Filter Number POINTS #6 #7 Total 1 2 3 1 2 3 1 231 224 237 215 199 206 2 229 226 219 205 218 211 3 219 213 220 189 220 196 Vav=V sum/9 224 207 Free Area 1.78 1.78 Filter CFM 399 368 767 Remarks: 2750 T16078 Tsurumaru Udon @ City of Arcadia 7/12 6B! GB$ G . mpang EXHAUST FAN CBI PROJECT Tsurumaru Udon @ City of Arcadia DATE August 29,2016 LOCATION: 400 S.Baldwin Ave.,Arcadia, CA 91007 BY IS/YS EXHAUST FAN TEST REPORT I EF BD Unit Data Unit No. KEF-1 KEF-2 Location _ Roof Roof Service KH-1 KH-2 — Type Centrifugal Blower Centrifugal Blower Manufacturer CaptiveAire CaptiveAire Model NCA18FA NCA18FA _ Serial No./Job Number /2662727(05/20/2016 Fan#2-3 of 8) /2662727(05/20/2016 Fan#2-4 of 8) _ c Type _ BI Centrifugal BI Centrifugal Ca 11 Rotation/Discharge CCW/Upblast CCW/Upblast Make Weg _ Weg i5 Model/Cat.No. 001580T1 BA056-S4OPK 001580T1 BA056-S4OPK Frame 56H 56H Enclosure/Type ODP/ ODP/ Service Factor _ 1.15 1.15 ___ Type Belt Belt __ a Belt(Q'ty)Size AX27 AX27 ` o Motor Sheave OD/Bore,in. 1VL40x5/8 1VL40x5/8 Fan Sheave OD/Bore,in. _ AK66x1 AK66x1 _ Centerline Distance,in. 6 3/4 6 3/4 Test Data Item Design Actual Design Actual — Airflow,cfm 2,400 2,612 _ 2,700 2,641 — m Speed,rpm NS I 644 NS 634 `l SP,in.wg 7/8 h NV 7/8 NV Power,HP 1.5 1.5 1.5 1.5 Speed,rpm 1745 1740 1745 1744 117 o Voltage, 115 116 115 - Phase/Hz 1/60 1 1/60 1/60 _ 1/60 — Current,amperes 13.6 FLA 9.52 13.6 FLA 8.99 Remarks: T16078 Tsurumaru Udon @ City of Arcadia 8/12 OBS EVAPORATIVE COOLER y" B S Company TEST REPORT PROJECT Tsurumaru Udon @ City of Arcadia DATE August 29,2016 LOCATION: 400 S.Baldwin Ave.,Arcadia, CA 91007 BY IS/YS UNIT DATA Unit No. MAU-1(SF-1) Location Roof Service Makeup Air for KH-1 and KH-2 Type Filtered Supply Fan Manufacturer PennBarry Model FS15B(Tag#SF-1) Serial No. D16AX42668(SD#H73561L13/MO#L160986) Type FC Centrifugal c LL Rotation CCW Discharge Downblast Make WEG Model/Item No. MO01C0X0X0000300646/10084786 o Type FC Centrifugal o Enclosure ODP Frame F56H Service Factor 1.15 Type Belt Belt Quantity/Size A62 N o Motor Sheave OD/Bore,in. MVL44x3/4 Fan Sheave OD/Bore,in. 9x1 1/8 Sheave Centerline Distance,in. 15 1/2 TEST DATA Items Design Actual Design Actual Airflow,cfm 4590 4812 • Speed,rpm 594 416 ESP,in.wg 0.5 NV Power,HP 1.5 0.75 Speed,rpm 1,740 1734 2 • Voltage 115 118 Phase/Hz 1/60 1/60 Current,amperes 20.4 FLA 13.90 Remarks: T16078 Tsurumaru Udon @ City of Arcadia 9/12 GM GB $ Company PROJECT: Tsurumaru Udon @ City of Arcadia DATE 8/29/2016 LOCATION: 400 S.Baldwin Ave.,Arcadia, CA 91007 BY IS/YS LEGEND AND ABBREVIATIONS LA CFD Calculated from Field Obtained Data NA Not Applicable/Not Available CFM Cubic Feet Per Minute No. Number DB Dry Bulb Temperature NPD Nameplate Data °F Degrees Fahrenheit NS Not Specified or indicated In.dia Inches in diameter NT Not Tested Due To Unfavorable Conditions IN.WG Inches Water Gage NV Not verified KH Type 1 Hood KEF Exhaust Fan for Type 1 hood PAC Packaged Gas Heat/DX Cool Air Conditioning Unit OAI Outside Air Intake EF Exhaust Fan EC Evaporative Cooler KEF Exhaust Fan for Commercial kitchen Hood WB Wet Bulb Temperature MAU Makeup Air Unit CW Clockwise SF-1 Filtered Supply Fan#1 VAV Variable Air Volume(Terminal Unit) DWDI Double Width Double Inlet CCW Counterclockwise TH Top Horizontal (E) Existing FLA Full Load Amperes SF Service Factor MCA Maximum Current Load HP Horsepower MOCP Maximum Overcurrent Protection Hz Hertz,Cycles per Second BI Backward Inclined ODP Open Drip-Proof UTR Up through roof OD Outer Diameter rpm Revolutions Per Minute UB UpBlast TAB TEST INSTRUMENT LIST TI-GBS Instrument No. AN2 TKM FH Function Air Velocity Measuring Rotating Measuring Air Volume Measuring(Direct) Range 50 to 4,500 fpm 6 to 30,000 rpm 0 to 2,500 cfm Min.Accuracy ±2% ±1 rpm t3% Name/Type Rotating Vane Anemometer Optical and Contact Capture Hood w/Digital Display Manufacturer Extech Shimpo Shortridge Model 707412 DT205B ADM850 Serial No. L539314 49801083 M95864 Calibration Date 1/13/2016 1/13/2016 1/13/2016 Instrument No. VMA VMA AN Function Voltage,AC Current,Amps Air Velocity Measuring Range 0 to 750 VAC 0 to 800 amps 50 to 4,500 fpm Min.Accuracy ±1%%of full scale 3%of full scale ±2% Name/Type _ Voltmeter _ Amp Probe Hot-Wire Multifunction Anemometer _ Manufacturer Extech _ Extech Kanomax Model 382040 382040 6501 Series Serial No. 96MA165011 _ 96MA165011 65312G0212 _ Calibration Date 1/13/2016 1/13/2016 1/13/2016 Remarks: T16078 Tsurumaru Udon @ City of Arcadia 10/12 GBS FLOOR PLAN GBS Compang CRI PROJECT: Tsurumaru Udon @ City of Arcadia DATE Aug,us t 29,2016 LOCATION: 400 S.Baldwin Ave.,Arcadia, CA 91007 BY IS/YS 0 L ...)c i p t N I piNI,• lit) To y.t U ) Tv -■ 1-:\ 5t L.'pact VAL $1!•k r , -•., .. .• , .._. 300 r. .0,,,, cn, ,.o I ; 100 ii. ANL , , in , s /. 7-.111 rr ,,..... kik pli oe‘ —1--. 7 , o • • -• - - • -"-'17=4.. 1/2 —l' ',0. f,-..m ' H . ..t.", . ,: i 1 ifs'q ilir N .."1-.1 'i. • . Ll,C2) ••::". 10-r-- '‘,:4.,,mni .:-...ND„, • .7... _ i; . ,.., ;....,.J. . ■..""""-.'WV cr:S,' .:"-''' ,';I" " "..... -rriA „ I W ALL ., • . • . ,... • ..---18"x211. vd, ,,,,,r-.., , I- ! Ata am ,-,• dp, 150 - .. . !_ _ I''.!' 1111101111111111eilf Alhallial (E) 18'46! , r___ - ___. w.......• _....4 ......_ ,f.!, _....5 (C) trot* 1 24%12 1.530 CPA ••P 0 C !-, (T1P.3) o, , • Ato 0 P.O.0,.•' i • ' \ II ''', f" ■; —' 11 0 i, 1 Bil Aiumor4.!....':' H, \ 11111 c )!(,---'1 tr.)v5sx i - ,' --- --t- . . ,• , ', r-- : \ , ' T f a .,. ... u , , ., . -17 „. II I , , ,.•.. ;... <-7.i \-..,, --) ■',.. .'..) II r I , : ■ , ...^.. , . 14.4* 1 , , • S...--, • icr. 10-. *--0--) ,........ 1 27,0, 0 1 NZ ■Is 1----1, . . , MECHANICAL — SECOND FLOOR PLAN __..._.. ... T16078 Tsurumaru Udon @ City of Arcadia 11/12 GBf ROOF PLAN GB $ Company PROJECT: Tsurumaru Udon @ City of Arcadia DATE August 29,2016 LOCATION: 400 S.Baldwin Ave.,Arcadia, CA 91007 BY IS/YS / — -- I \\ Sc-t 11 I \ I Kff i 1 T 1 1 I I 10'-0'MIN.FROM ANY 0 I I OUISiOE MR INTAKE 1 I I 1 1 1 F 'i 1114 - / < 1\ V k.—\.)1 `\\ //VARA\ \ / //�v�� a // \\\ / ��.', ../ \ SEE SHEETS M-3.0 1}1RU f / - 1 M-3.2 FOR ELECTRICAL ' / _ � 1 INFORMATION I I 1 I I 10'-0.MIN.FROM ANY j I 2 S OUTSIDE AIR INTAKE 1 I 1 I I 1 / 1 / 1 / \ / \ / \ / N. / . i 1 MECHANICAL - ROOF PLAN _IIII". T16078 Tsurumaru Udon @ City of Arcadia 12/12 LOS ANGELES COUNTY DEPARTMENT OF PUBLIC WORKS . ( BUILDING &SAFETY/LAND DEVELOPMENT DIVISION t `t SPECIAL INSPECTION REPORT Each inspector must complete this report and mail it to the District office where the permit was issued. X DAILY n WEEKLY FINAL Total time on job(in days) ONE Day Building Permit No. B00-053-334 Job Address 400 S. BALDWIN AVE. #231, ARCADIA, CA General Contractor JENHO CONSTRUCTION Size of Building No. of Stories Type of Wall Type of Work : Reinforced Concrete n Masonry n Hi-tensile Bolting n Pre-stressed Concrete [71 1 Welding n Gypsum conrete n Other(D.I.A) Discription of work inspected 1)T.I FOR COMMERCIAL BUILDING. 2) WORK DETAIL PER S-1.DECK OPENING REINFORCEMENT. ***REMOVED(E)FIREPROOFING COAT&CLEANED @ WELDING LOCATION. i)WELDED SHEAR PL.(1/4"THK.)TO(E)BEAM W/1/4"FILLET WELD(2 SIDES) FOR PRIMARY BEAM.(8 PLACES) ii)WELDED CONNECTION PL.(1/4"THK.)TO(N)BEAM(C 6X8.2)W/1/4"FILLET WELD FOR 2NDARY BEAM.(4 BEAMS, 12 PLACES) iii)INSTALLATION OF(N)BEAMS(C 6X8.2)USING 3/4"DIA.A307 BOLT.(2 PLACES, 10 BEAMS) 3)FILLER METAL.AWS A5.20.E71T-8,0.072"DIA.,F.C.A.W. 4)WELDING WAS PERFORMED BY CEERTIFIED WELDER. i)MIN KIM,AWS D1.1.SMAW&FCAW(3G+4G) All works on this job to date has been satisfactorily completed to the approved plans and requirements of the Los Angeles County Building Code. C.O.L.A #P015050(W/C/M/SC/DIA) JAYEE J. KIM L.A.COUNTY#01475(W/M/C) 8/12/2016 Special Inspector(Print) I.D. Number Date "xff lL—„ (562)331-5700 Special Inspector(Signature) Daytime/Cell Phone Number LOS ANGELES COUNTY DEPARTMENT OF PUBLIC WORKS v. BUILDING&SAFETY/LAND DEVELOPMENT DIVISION fsr , 0 t; SPECIAL INSPECTION REPORT Each inspector must complete this report and mail it to the District office where the permit was issued. 17 DAILY x WEEKLY (FINAL Total time on job(in days) ONE Day Building Permit No. B00-053-334 Job Address 400 S. BALDWIN AVE. #231, ARCADIA, CA General Contractor JENHO CONSTRUCTION Size of Building No. of Stories Type of Wall — Type of Work : Reinforced Concrete Masonry Hi-tensile Bolting Pre-stressed Concrete n Welding n Gypsum conrete x Other(FIREPROOFING) Discription of work inspected 1)T.I FOR COMMERCIAL BUILDING. 2) APPLIED MONOKOTE FOR THERMAL&MOISTURE PROTECTION @ DISPATCHED SPOT FOR WELDING &METAL STUD BRACING. i)THICKNESS (MIN. 3") ii) MATERIAL.MONOKOTE,MK-6/HY iii) APPLIED 6 COATS OF MONOKOTE.(DURATION;5 DAYS) 3) MATERIAL. ICC-ESR#1186. All works on this job to date has been satisfactorily completed to the approved plans and requirements of the Los Angeles County Building Code. C.O.L.A #P015050(W/C/M/SC/DIA) JAYEE J. KIM L.A.COUNTY#01475(W/M/C)/I.C.0#5031455(F.P) 8/19/2016 Special Inspector(Print) I.D. Number Date (562)331-5700 Special Inspector(Signature) Daytime/Cell Phone Number «,n LOS ANGELES COUNTY DEPARTMENT OF PUBLIC WORKS :iii `' BUILDING&SAFETY/LAND DEVELOPMENT DIVISION PUBLIC.WORKS'. • "�. SPECIAL INSPECTION REPORT Each inspector must complete this report and mail it to the District office where the permit was issued. M DAILY n WEEKLY C FINAL Total time on job(in days) l2 Day Building Permit No. 23& BDO-Q5 3- 334 Job Address 4 00 —C. 134/- IANN ARC/1b/4 General Contractor 4-ARy /CAA/AM Size of Building No. of Stories Type of Wall Type of Work : fl Reinforced Concrete LI Masonry C Hi-tensile Bolting Cj Pre-stressed Concrete ❑Welding C Gypsum conrete Other(D.I.A) Discription of work inspected /, 7/us/c/fir- /tepRo✓s „/T � waek Af 7Z/c PER A /Woe BU/L /Ie d c-4,c% Hc7t s /.t:s//vq► � �i L /4-he &J/Re Busy i '� w� ' L` Ar ' .S/148 C/(N 8" _) ® /6" v�/2 7 /A,/B/4/G' 7 'JC 1. C 7-0/"..4./ 3a /cam Apl a=s./1./ 1.Sc/ c#s/ 7 .- '- icy--�s R 233'R �,/ . G/ -03 ?D/8 All works on this job to date has been satisfactorily completed to the approved plans and requirements of the Los Angeles County Building Code. C.O.L.A #P015050(W/C/M/SC/DIA) JAYEE J. KIM L.A.COUNTY#01475(W/M/C) a 7 /5 - o�S Special Inspector(Print) I.D. Number Date (562)331-5700 Special I ector(Signature) Daytime/Cell Phone Number