HomeMy WebLinkAboutDecision LetterV, October 4, 2017
d Herand derSarkissian
520 E. Glenoaks Blvd, Unit D
Glendale, CA 91207
SUBJECT: Major Administrative Modification — AM Major 17-15
C,
t `y O� PROJECT ADDRESS: 218 Las Tunas Drive (formerly 2700 Gilpin Way)
ArcadiaDear Herand derSarkissian:
The Development Services Department has denied the request to construct a
Development second driveway that would be a substandard circular driveway, as shown below
Services in Figure 1, to accommodate a new single-family residential development at 218
Department Las Tunas Drive. The development received prior entitlements under the 2700
Gilpin Way address, but the project site has since been reassigned to a new
address, 218 Las Tunas Drive. Attached are the site plans, and other supporting
exhibits.
Jason Kruckeberg
Assistant City Figure 1: Site Plan
Manager/
Development Services ,.,, 179.60
--
arc = —=�• "
Director- -----�—._ m
» to PL
i
154.50
wC
_ N us TUNAS NWIE
i
The comment period for the Notice of Pending Decision ended on September
25, 2017. Staff received one letter of opposition from a neighbor during the
comment period. The neighbor's raised concerns regarding the project's impact
on uniformity of development for circular driveways and the potential hazards the
new circular driveway would introduce on Las Tunas Drive.
Modifications
240 West Huntington In addition to requesting a second driveway, the driveway does not meet other
Drive development standards as shown in Table 1, including the minimum distance
Post Office Boxfrom the front property line and it exceeds the maximum hardsca a requirement
Arcadia, CA 91066-666-6 021 p p y P q
(626) 574-5415 of 40% within the required street -side yard setback area. Because the
(626) 447-3309 Fax modification requests include reduction to the landscaping area, the entire
www.ArcadiaCA.gov project is subject to a Major Administrative Modification.
Table 1: Project Modifications
Modifications
Development Code Sections
9 feet inside edge instead of the
9103.07.050(H)(4)
required 25-feet.
Exceeds 40% maximum hardscape
9103.07.050(G)(4)(d), and
in front and street side setbacks.
9103.09.040 B 1 b
Use of turf block for driveway paving
9103.07.050(G)(1)
material instead of cement
concrete.
Use turf block to meet both
9103.07.050(G)(1),
landscape, and driveway
9103.07.050(G)(4)(d), and
minimum.
9103.09.040 B 1 b
The project site is a reverse corner lot located within the zone R-1 (10,000) that had one
driveway located on Las Tunas Drive at the rear (east) of the site. The subject lot is
approximately 12,166 square feet. Its dimension of approximately 68 feet wide by 179.5 feet in
length with a 164.5 frontage on Las Tunas Drive exceeds that of the required length by almost
80% making up for a 10% shortfall in minimum lot width. A new 5,065 square -foot two-story
house is currently under construction, which includes a 23 -foot wide standard driveway off of
Las Tunas Drive. To ensure that circular driveways are designed properly and retain the
intended shape, the required circular driveway minimum setback is 25 feet measured to the
inside edge, and the application requests a significant reduction to nine feet. In addition, the
minimum hardscape along the street side yard area is 40%, which the project exceeds by 20
square feet.
Findings
Pursuant to Development Code Section 9107.05.050, a Major Administrative Modification may
be approved if at least one of the three required findings can be made:
Secure an appropriate improvement of a lot
2. Prevent an unreasonable hardship
3. Promote uniformity of development
Based on the facts presented by the applicant, and review and analysis by staff of the
modification requests, none of the findings can be made for the proposed driveway, as stated
below.
Secure an appropriate improvement of a lot
The proposed substandard circular driveway would not secure an appropriate improvement to
the lot because it would be situated too close to the property line at 9'-0" instead of 25'-0" as
required per Code and exceed the maximum hardscape of 40% along the required street -side
yard setback area. The City Engineer also determined that the proposed request creates an
unsafe improvement to the site since the addition of the another driveway would impede on
traffic safety and left turn restrictions. Therefore, staff determined that the design and location of
the proposed driveway is not an appropriate to the site or to the existing traffic patterns along
Las Tunas Drive.
2. Prevent an unreasonable hardship
The Applicant stated that the additional driveway is necessary to maneuver their vehicles out of
the site in a forward motion. The applicant's further justification for the circular driveway includes
safety and convenient of vehicular ingress and egress to the property, and to garage that is
located off of Las Tunas Drive. The applicant further stated that the circular driveway is
"inbound" only and therefore capable of minimizing traffic safety impacts. Since the City has no
ability to control, monitor, and therefore ensure, inbound/outbound-only driveway access, staff
cannot support the proposed project.
Staff cannot support the modifications to accommodate a new substandard circular driveway
since there are safety concerns with the location of the proposed circular driveway, the
substandard configuration is not consistent with the other circular driveways along Las Tunas
Drive, and the westerly driveway approach creates a traffic safety issue. The property owners
also designed their house and site to have the garage for the new residence off of Las Tunas
Drive rather than Gilpin Way. For these reasons, there is no hardship to warrant a substandard
circular driveway.
3. Promote uniformity of development
The Applicant compared his request to other residential properties that had a circular driveway,
including commercial properties such as gas stations and drive-thru restaurants, and how he felt
they were similar to the proposed driveway. Staff analyzed these residential addresses;
however, none of those driveways were comparable to the applicant's overall proposal since
they were not located as close to the front property line. It was unreasonable to compare a
residential driveway to a driveway on a commercial zoned property since they have different
development standards and requirements. Furthermore, none of those driveways required a
modification as they were all in compliance with the code at the time they were approved. The
application is the first modification request for a circular driveway in a residential zone since the
Development Code was updated in 2016. Development Code Section 9107.01.040(B)(2)
(Burden of Proof and Precedence) of the Development Code specifies, "The granting of a prior
permit either on the subject property or any other property within the City does not create a
precedent and is not justification for the granting of a new permit under current review." In
addition, the City Engineer's decision not to approve a curb cut permit for the circular driveway
is due to the location of the raised center median directly across the property on Las Tunas
Drive, and the addition of the another driveway would impede on traffic safety and left turn
restrictions.
Approval of a substandard circular driveway on Las Tunas Drive for the property would actually
change the uniformity of the development pattern found on other residential properties with a
circular driveway, therefore, the finding cannot be made.
Environmental Analysis
The proposed project qualifies as Class 5 Categorical Exemption for an accessory structure and
a minor alteration in land use limitations from the requirements of the California Environmental
Quality Act (CEQA) under Section 15305 of the CEQA Guidelines.
There is a ten (10) day appeal period for this application. The appeal period ends on Monday,
October 16, 2017 at 5:30 p.m. Please note that City Hall will be closed on Friday, October 13,
2017. To file an appeal, a completed Appeal Application form must be submitted to the
Community Development Division along with a $600.00 appeal filing fee.
You may visit the City's website at www.ArcadiaCA.gov/noticesanddecisions to view this letter.
If you have any questions regarding the above approval after October 10, 2017, please contact
Vanessa Quiroz, Assistant Planner at (626) 574-5422 or by email at VQuiroz@ArcadiaCA.gov.
Thank you.
Sincerely,
DEVELOPMENT SERVICES DEPARTMENT
Communi Development Division/Planning Services
ry n He an s'`' Lisa L �' lores
Con Planner Planning/Community Development Administrator
c: Mr. and Mrs. Liang, Property Owners
Chih-Hung Hsia
ALL GRADES TAKEN FROM SURVEY 3650 S.F. TOTAL SIDEYARD AREA
BY TRI -TECH ENGINEERING 1117 S.F. PAVED 30% -.
ASSOCIATES, 883 S.F. TURF BLOCK 24% DENIED
EX]bT HOUSE _ I
-JOB # 150315, DATED 3 / 18 115 2533 S.F. LANDSCAPED 69% _ - -- _
FRONT SETBACKS OF THE NEXT TWO RESIDENCES y
EXISTING WU IIT, OCT O 4 201.71
FENCETOREMNN I
EXIST. GALA FENCE j (Bl'B9E)
RANOOMBELGIPN - - WALL TOftEMNN (35f 1 feG E� planning Servii es
PAVERS BY REMOVE EXIST. CMU
CORONADO STONE FENCE WALL _
COMPANY-12'X1B- 6'L-HIGHFENCE8 CCHNEROF 'r o,A City of Arca I a
AND R'XIW GATE.SWILAATO EXRNEROFTING HOUSE
(359 e)
NEW FENCE WALL
79.50 / G-. (W'
(3 6)
n aN. da
i
ye.tl p IaIM a.. nn .rt _/ d EXISTING
TREES _.TO NR—CAN TREE
w AI
MIN
ppa'mi1�1 p 1�. - \
LElpypB , Y 11 a10 en-' I _ (360.41)
V/
4(36030) 1 -\
EXISTING CMU
FENCE TO REAPJN III---111AAAllL..n
. -- y I ..�• rsnWlarvino
I GARAGE IWILIAMSER
TREE TO NOWAIN
TREE TO fiL%SAIN _- \
VIM
t6'3'i26 J }
,;-T HIGH FENCE& a"R 16 �1�
A+o
GATESIWLARTO �� x f J �'•'�
an __, .... rcT359
Z_15)
A
JERPGE FRONT SET34Crc d
LANDSCAPING \ j tIP / END OF EXISTING SIDEWALK
'1 w+oscAPLNG ,
_ EXISTING SIDEwALKTo REMNN
CLEAR
L L ." L L.
_.. �.
�v
��(�
RECEIVED
SRHT LINE
�
CLEM
BIGHTLwf
16450'
IANOSCAPINO
(B6'6CF�
LANDSCAPING
DRIVEWAY
(49993)
/ j
/.'
Ili
LANDSCAPING
-
_
TC(33B9S)
- EXISTING
TSB
MNLBO%SEE
❑
- -...
AUG 2 4 2017
—
_
:.�^. , W w
WORK IN PUBLIC
RIGHT OF WAYB
RIGHTO
TC(35865)
u u
TC(]59.30)
_.-_
.' a `�
SEPARATE PERM
gN DRIVEWPOFGIRB
`� PERGTY OF PRCMIP
35892
�m mm
?lPE �-
C3%.]q
19614J2•TC(359.D7!
- --
&N
•--
---
Planning Services
STANDARDS
SITE PLAN LAS TUNAS DRIVE
N —
SCALE: 118"= P-0"
wa. �alw wNEwncwwm
scoxc.Euxroas+aX,oe..N —
txtcHaA:EA ---
uwscrewo
\
.,.��w.AEIWE _
TYPICAL CURB
9.Ir a, TYPICAL PILASTER
City of Arcadia
FENCE BY SEPARATE PERMIT
A-1 G 9iswEw Snonrowicxl,¢ -- -
nESlrcxEewwdnvuaaxoa f / / /
_-__\ - -fIS BiVNEWCMW T4 6iO:E VExEExiO%MiM I¢91OExtE-
_...
Ep
- dNGE MNI.�X9PL4Y,PY. M,W -- .
\ pa: MaCKMNx,LGP o 4 e
� - _ wmnauaeum w�a.
i•X?axcvE - :acR ewacawxoow
1=3w.ai'uaoexce ro ,
e
71 N
L eo a a o e o e o c e oe
n4 I -
SCALE:
at TYRPILASTER i mEI+B- aI MAILBOXDETAIL u• IA.t MAILBOXPILASTER PLAN (s nE-t G- n-. TYP. FENCE&GATE LL•IAiION urz'=
e
He and
derfaerkissian
aurae bdwNWItKN@=mFeRO nw
RESIDENCE
for
MR. & MRS. LIANG
1..APW.TMC1'<9 ueVAXa
JANETTE LIANG
GOKIN INVESTMENTS
INC
SITE PLAN &
SITE DETAILS
�E BME A-1_