Loading...
HomeMy WebLinkAboutUntitled . Development Services Department i' 111P4 il 240 West Huntington Drive,Post Office Box 60021 'Arcadia, CA 91066-6021 PERMIT NO. $QQ-056-109 City of (626) 574-5416 Fax(626)447-9173 Arcadia Permit Type: Tenant Improve w/energ; PROJECT TRACT NO. LOT NO. APPLICATION DATE ISSUED BY PRINT DATE PERMIT STATUS 2/21/2017 CM 8:21 6/27/2017 Issued ADDRESS NO. Dir.Prefix Street Name Street Suffix UNIT BLG ASSESSORS PARCEL NO. GEO CODE 400 S Baldwin Ave T-387 OWNER MAILING ADDRESS Westfield Corporation, Inc. 11601 Wilshire Blvd. 12th Floor PHONE NO. Inspector#: HENRY Los Angeles,CA 90025- EMAIL ADDRESS: Plan Chk#: 17-50 APPLICANT MAILING ADDRESS . Bogart Construction Inc. PHONE NO. EMAIL ADDRESS: , CONTRACTOR/PROFESSIONAL MAILING ADDRESS 949 NO. Bogart Construction Inc. 12 Mauchly Building F PHONE (949)453-1400 FAX NO. Irvine, CA '92618 EMAIL ADDRESS: License No. 707471 Type: B Expires: 5/31/2019 12:00: TENANT MAILING ADDRESS Iss Bath And BodY la VWorks ,v NE NO. FAX NO. , DESCRIPTION - BATH AND BODY WORKS T.1,WITH EMP Construction Type UOM #of Units Value Construction Type UOM 8 of Units Value Value Value 425,000.00 $425,000.00 OCCUPANCY: Tenant Improve TOTAL VALUATION: $425,000.00 QTY 1.1OM DESC AMT AMT PAID ACCT QTY DOM DESC AMT AMT PAID ACCT each Plan review 2,253.23 2,253.23 01-3103 153.00 each Ltg fixtures 163.80 163.80 01-3105 each Energy p/c fee 693.30 . 693.30 01-3103 13.00 Flat Add/Alter Ducts 121.94 121.94 01-3105 PC ADA 337.98 337.98 01-3103 1.00 each Wtr htr/vent 15.55 15.55 01-3105 PC Cal Green 225.32 225.32 01-3103 1.00 each T.I.Fire Pkc 280.00 280.00 01-3109 1.00 Flat Bldg Issue Auto 44.35 44.35 01-3104 SMIP Com 119.00 119.00 14-2207 each Bldg permit 3,466.50 3,466.50 01-3104 gm bldg std 17.00 17.00 714-2203 Bldg Issue ADA 346.65 346.65 01-3104 1.00 Flat SWMF Auto 6.25 6.25 88-3027 1.00 flat Elec issue 44.35 44.35 01-3105 1.00 Flat SWMF 2 1.00 1.00 88-3027 1.00 Flat Mech issue 44.35 44.35 01-3105 1.00 Flat SWMF 2 1.00 1.00 88-3027 1.00 Flat Plmbg issuance 44.35 44.35 01-3105 1.00 Flat SWMF 2 1.00 I.00 88-3027 1.00 each Water Closet 12.46 12.46 01-3105 1.00 each Fan-vent single 9.38 ' 9.38 01-3105 1.00 each Lavatories 12.46 12.46 01-3105 3.00 each Distrib panel 46.65 46.65 01-3105 1.00 each Floor sink 12.46 12.46 01-3105 1.00 each Air unt 10m cfm 14.11 14.11 01-3105 116.00 each Outlets 126.80 126,80 01-3105 Total Fees: $8,461.24 Balance Due: $0.00 Paid Today: $4,671.41 This permit/plan review expires by time limitation and becomes null and void if the work authorized by the Receipt#: 117208 permit is not commenced within 180 days from the date of issuance or if the permit is not obtained within 180 days from 01-3104 3,857.50 the date of plan submittal.This permit expires and becomes null and void if any work authorized by this permit 01-3105 668.66 is suspended or abandoned for 180 consecutive days or if no progressive work has been verified by a City of 14-2207 119.00 Arcadia building inspector for a period of 180 consecutive days. 714-2203 17.00 88-3027 9.25 CALLS FOR INSPECTION INSPECTORS'OFFICE HOURS Requests for inspection should be made at least Monday-Thursday Friday one(1)business day in advance of the inspection 7:30 a.m.to 8:30 a.m. 7:30 a.m.to 8:30 a.m. by telephone at(626)574-5416 for onsite work. 4:00 p.m.to 5:30 p.m. 4:00 p.m.to 4:30 p.m. (Closed on alternate Fridays) ////9 of AR0 4_„woI��g4 °~ -,,,k ' PERMIT/PLAN REVIEW APPLICATION Development Services Department,240 West Huntington Drive,Post Office Box 60021 mOj..„o(N° Arcadia, CA 91066-6021, (626) 574-5416,Fax (626) 447-9173 City of Arcadia LICENSED CONTRACTOR'S DECLARATION WORKERS'COMPENSATION DECLARATION ❑ I hereby affirm under penalty of perjury that I am licensed under provisions of I hereby affirm under penalty of perjury one of the following: Chapter 9(commencing with Section 7000,of Division 3 of the Business and Professions Code.,jjand my license is in full force and effect. f ❑ I have and will maintain a certificate of consent to self-insure for workers' D License Class License 1 I Exp. Date 311 1 1 [Signature of Contractor compensation, as provided for by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. OWNER-BUILDER DECLARATION ElI have and will maintain workers'compensation insurance,as required by Section ❑ I hereby affirm under penalty of perjury that I am exempt from the Contractors 3700 of the Labor Code,for the performance of the work for which this permit License Law for the following reason(Section 7031.5,Business and Professions is issued.My workers'compensation insurance carrier and policy numbers are: Code.Any city or county which requires a permit to construct,alter,improve, Carrier Qvv r/ ( 4E— demolish, or repair any structure,prior to its issuance,also required the applicant for such permit to file a signed statement that he or she is licensed pursuant to the Policy Number provisions of the Contractors License Law(Chapter 9(commencing with Section (This section need not be completed if the permit is for one hundred dollars or less) 7000) of Division 3 of the Business and Professions Code) or that he or she is exempt there from and the basis for the alleged exemption. Any violation of ❑ I certify that in the performance of the work for which this permit is issued,I shall Section 7031.5 by any applicant for a permit subjects the applicant to a civil not employ any person in any manner so as to become subject to the workers' penalty of not more than five hundred dollars($500)): compensation Laws of California,and agree that if I should beco re subject to the workers'compensation provisions of Section 3700 of the Lab f Code,I shall ❑I, as owner of the roe forthwith comply with those provisions. f property,rty, or my employees with wages as their sole compensation,will do the work,and the structure is not intended or offered for O. sale(Section 7044,Business and Professions Code:The Contractors License (Date (ii �� Signature �� Law does not apply to an owner of property who builds or improves thereon, or who does such work himself or herself or through his or her own employees,provided that such improvements are not intended or offered for WARNING: Failure to secure Workers'Compensation coverage is unlawful, sale.If,however,the building or improvement is sold within one(1)year of and shall subject an employer to criminal penalties and civil fines up to one completion,the owner-builder will have the burden of proving that he or she hundred thousand dollars($100,000),in addition to the cost of compensation, did not build or improve for the purpose of sale). damages as provided for in Section 3706 of the Labor Code, interest, and attorney's fees. ❑I, as owner of the property, am exclusively contracting with licensed contractors to construct the project(Section 7044, Business and Professions Code:The Contractors License Law does not apply to an owner of property CONSTRUCTION LENDING AGENCY who builds or improves thereon, and who contracts for such projects with a I hereby affirm under penalty of perjury that there is a construction lending agency contractor(s)licensed pursuant to the Contractors License Law). for the performance of the work for which this permit is issued (Section 3097, Civil Code). ❑ I am exempt under Section 7044,Business and Professions Code,for this reason: Lender's Name Date Signature Lender's Address IMPORTANT: APPLICATION IS HEREBY MADE TO THE BUILDING OFFICIAL FOR A PERMIT SUBJECT TO THE CONDITIONS AND RESTRICTIONS SET FORTH ON THIS APPLICATION AND THE FOLLOWING: 1. The City's approved plans and permit inspection card must remain on the job site for use by City inspection personnel. 2. Final inspection of the work authorized by this permit is required.A Certificate of Occupancy must be obtained prior to use and occupancy of new buildings and structures. 3. Per South Coast Air Quality Management District(AQMD)regulations,renovation and remodeling work that results in the removal,stripping,or altering of asbestos containing materials requires an asbestos survey and removal prior to disturbing the asbestos.Please contact AQMD at(909) 396-2000 for further information. Name 6'ry'1 l_c"�C_�1 D Title ,041:pf IT-- ` J 1.` PRINT NAME I certify that I have read this application and state that the above information is correct and that I am the owner or duly authorized agent of the owner. I agree to comply with all City ordinances and State Laws relating to building construction. I hereby authorize representatives of the City of Arcadia to enter upon the -mentioned pr, r•rty for inspection purposes. SignatureIV Date (0lZlI—1 ycrc> • &Aro- e# QO/ Gtf�Xks �,�N/OTES Building Inspections Date Insp. Plumbing Inspections Date Insp. ..$_4-� F l `" - t� reiG 100. Setbacks 210. Under 1K/bldg.drain 9-S-17 G / 101. Rough grade 211. Copper underslab Q�I'E a F-512- ��GC.S OcAe61 »'*J 102. Figs.&forms 212. Rough plumbing a 3-/7 ddd 103. Pre-slab 213. Rough gas _ 104. Floor joists 214. Shower pan _ - Z 7 /L-0444146- 5TLT7arf /7- 105. Steel 215. Water heater "48-17 106. Grout lift 216. Roof drains 107. Shear nailing 217. Building sewer 108. Diaph nailing 218. Water service es-(G-1? 4IVA C Do-cr r,� time 109. Roof nailing 219. Final gas 110. Framing $0e-f7 220. Fixtures 111. 0cc./Area Sept.Wall / 221. Final plumbing "-18-1? z 112. Sound walls 222. Sewer cap/demo. 113. T-bar.rid 114. Insulation-Flr. Pool Inspections Date . Insp. 115. Insulation-Wall 240. Excavation/steel 116. Insulation-Ceil. 241. Rough plumbing 117. Drywall nailing f•30•!7 D`! 242. Light shell/bonding 118. Interior lath 243. Underground conduit 119. Exterior lath 244. P-trap 120. Finish grade 45. Gas line&test 121. Final building 03-17 246. Fence,gates&signs 122. Final demo/lot clear 247. Pool heater 248. Final electric Electrical Inspections Date Insp. 249. Final.lumbin. 150. Power pole 250. Pool cover - 151. Sales lot lighting 251. Pool final 152. Underground conduit ta...1--rage 153. Underslab conduit Reroof Inspections Date Insp. 154. UFER ground 270. Pre-reroof insp. 155. Water ground 71. Roof framing 156. Rough electrical f q-rf � '�' 272. Sheathing nailing 157. Fixtures `e 273. Final reroof 158. G.F.C.I. 159. Eqpt.bonding Sign Inspections Date I Insp. 160. Service panel q.-(? 280. Setback/overhang 161. Final electric 281. Footing 282. Conduit/wiring Mechanical Inspections Date Insp. 283. Disconnect 180. Venting/flue 84. Final sign 181. Furnace/A.C. _c.1 ,i' 111, 182. Rouch HVAC � jai= Miscellaneous Insp. I Date I Insp. 183. Fire dampers 290. Fire alarm 184. Furnace compartment 291. Underground supply 185. Combustion air 292. Fire sprinklers 186. Smoke detectors 293. Monitor system 187. Metal F.P.rough 294. Hood dry chem. 188. Compressor setback 295. Final 189. Commercial hood 190. Duct shaft Sewers&Offsite Insp. Date Insp. 191. Final mechanical 9-27/7 ;FIR." 300. Lateral(main to P/L) 301. Saddle/Y Block Wall Inspections Date Insp. 302. Cess tool filled 200. Footings 303. Sidewalk 201. Steel/rebar 304. Driveway 202. Grout lift 305. Curb replacement 203. Final wall 306. Trash bin fi g. x. 'AIWA, ),;&.-_,...: ,4110.10„_„_444,, .00.0„.„411102 ,,,___41_ �iA•? fg,,ate-trt. ... , °t,,meq , a#kl. =-1.—ii, :ri,,„ r.<'.: _e J:"-"'• 'z _^aA„i �__'',.: �� SS _ 1® a ® ® ® -®'•1'�FCe ® �,��I _fr " Al; , ., ,. T'3:� �....._.. v� _• ._.. __ ^..d.. ...� ..,..,a..:�:,.::.tMr,......- ._dC,_.nl _..sw ,8.e _.. �Q �7 4titC ' ' (1 .‘,...c.),...1.L...._1r1%. : IP.1. elit 'AV5b Ai A*4''' ' ' t ,..„4., „ V , " 047"4-iit, RPORAt890 614 I Gert cafe sof occupancy ® f 7,74 0I City of Arcadia � � c::08 . '77. a Development Services Department - Building Division ®7, Vivi : �� This certificate issuedpursuant to the requirements of Section 109 of the ® Uniform Building Code certifying that at the time of issuance this structure was in C.�a": compliance with the various ordinances of the City regulating building construction or use. �� r l j . , % . Permit No. . B00-056-109 `" � 4 Building Address: 400 S Baldwin Ave,Arcadia,CA 91007at, ' Use Classification: Tenant Improve Effective UBC: i ii . €1 p C.B.C.2016 ®i_ k. tP p Permit Type: Tenant Improve w/energy Zone Code: C-2,DH8 �' Occupancy Code: l�I Type of Construction: � .� A yp TYPE II ] HR ��, �� Final Date: 10/3/2017 "76 Owner: Westfield Corporation,Inc. c>4� �� 4 Tenant: Bath A (: Body Works ---‘'ef :.::, V:' h,„:44/ „ %,,,„4„ , 0'40 kr 0 Don Stockham,Building Official *� 9 � 4,. :' _ POST IN A CONSPICUOUS PLACE '^ \ ,,. fa4 eo. ' ).--AN .1 _ 6 ;.j .'._.a .•w_,..,,. -�.sw ron. raF""".,.a°` ." ?• r 'sw' " " x w ._- , p, o, ' Mf n..�-_. �_ ® ® I .`j#,/� 4 �� p. �._` ,',$'?" w.1481 \} 4 wi ',4 14t ::,7-,t. .4,,‘, —:-) .4:!---•• Development Services Department • 240 West Huntington Drive,Post Office Box 60021 PERMIT NO. • ��..- Arcadia, CA 91066-6021 B00-056-693 City of (626)574-5416,Fax(626)447-9173 ArcadiaPermit Type: Sign PROJECT TRACT NO. LOT NO. APPLICATION DATE ISSUED BY PRINT DATE PERMIT STATUS 4/27/2017 EP 10:29 4/27/2017 Issued ADDRESS NO. Dir.Prefix Street Name Street Suffix UNIT BLG ASSESSORS PARCEL NO. GEO CODE 400 S Baldwin Ave T-387 OWNER MAILING ADDRESS Westfield Corporation, Inc. 11601 Wilshire Blvd. 12th Floor PHONE NO. Inspector#: HENRY Los Angeles, CA 90025- EMAIL ADDRESS: APPLICANT MAILING ADDRESS R N F Signs ENO. 1151 ttlat 1 IL ADDRESS: CONTRACTOR/PROFESSIONAL MAILING ADDRES' �626 NO. 991-9049 FAX NO. R N F Signs 330 E Newmark Ave PHONE Monterey Park, CA 91755 EMAIL ADDRESS: License No. 1004002 Type: C45 Expires: 5/31/2017 12:00: TENANT MAILING ADDRESS Bath&Body Works/White Barn PHONE NO. FAX NO. DESCRIPTION FOUR CHANNEL LETTER ILLUMINATED SIGNS FOR BATH&BODY WORKS,WHITE BARN Construction Type UOM 8 of Units Value Construction Type UOM #of Units Value Value Value 8,000.00 $8,000.00 OCCUPANCY: Sign TOTAL VALUATION: $8,000.00 QTY UOM DESC AMT AMT PAID ACCT QTY UOM DESC AMT AMT PAID ACCT Sign plan rev ' 114.16 114.16 01-3103 1.00 Flat Bldg Issue Auto 44.35 44.35 01-3104 each Bldg permit 203.85 203.85 01-3104 1.00 flat Elec issue 44,35 44.35 01-3105 4.00 each Sign Connection 62.20 62.20 01-3105 1.00 Flat SWMF 2 1.00 1.00 88-3027 1.00 each SWMF 2 Auto 1.00 1.00 88-3027 Total Fees: $470.91 Balance Due: $0.00 Paid Today: $470.91 This permit/plan review expires by time limitation and becomes null and void if the work authorized by the Receipt#: 116539 permit is not commenced within 180 days from the date of issuance or if the permit is not obtained within 180 days from 01-3103 114.16 the date of plan submittal.This permit expires and becomes null and void if any work authorized by this permit 01-3104 248.20 is suspended or abandoned for 180 consecutive days or if no progressive work has been verified by a City of 01-3105 106.55 Arcadia building inspector for a period of 180 consecutive days. 88-3027 2:00 CALLS FOR INSPECTION INSPECTORS'OFFICE HOURS �\ Requests for inspection should be made at least Monday-Thursday Friday \\ one(1)business day in advance of the inspection 7:30 a.m.to 8:30 a.m. 7:30 a.m.to 8:30 a.m. Vv by telephone at(626)574-5416 for onsite work. 4:00 p.m.to 5:30 p.m. 4:00 p.m.to 4:30 p.m. (Closed on alternate Fridays) r , 4u OC oR,yQ %� (t PERMIT/PLAN REVIEW APPLICATION 0\t"j*•, Development Services Department,240 West Huntington Drive,Post Office Box 60021 Arcadia, CA 91066-6021, (626) 574-5416,Fax (626) 447-9173 City of Arcadia LENSED CONTRACTOR'S DECLARATION WORKERS'COMPENSATION DECLARATION ereby affirm under penalty of perjury that I am licensed under provisions of I hereby affirm under penalty of perjury one of the following: Chapter 9(commencing with Section 7000,of Division 3 of the Business and Professions Code,hand my license is i• ull force and effect. 2 ❑ I have and will maintain a certificate of consent to self-insure for workers' License Class C,—f� L' : %% 1. M%OOS Exp. Dates'J1'�� compensation, as provided for by Section 3700 of the Labor Code, for the Signature of Contractor •,,, performance of the work for which this permit is issued. WNER-BUIL I i R DELL.!' TION have and will maintain workers'compensation insurance,as required by Section El hereby affirm under penalty of perjury that I am exempt from the Contractors 3700 of the Labor Code,for the performance of the work for which this permit is issued.My workers'compensation insurance carrier and policy numbers are: License Law for the following reason(Section 7031.5,Business and Professions C.t�1 n 'C` J�`� \ Code.Any city or county which requires a permit to construct,alter,improve, Carrier kake \ 1n (J � ki demolish,or repair any structure,prior to its issuance,also required the applicant 1 \� _ �\I rt for such permit to file a signed statement that he or she is licensed pursuant to the Policy Number �V provisions of the Contractors License Law(Chapter 9(commencing with Section (This section need not be completed if the permit is for one hundred dollars or less) 7000)of Division 3 of the Business and Professions Code)or that he or she is exempt there from and the basis for the alleged exemption. Any violation of ❑ I certify that in the performance of the work for which this permit is issued,I shall Section 7031.5 by any applicant for a permit subjects the applicant to a civil not employ any person in any manner so as to become subject to the workers' penalty of not more than five hundred dollars($500)): compensation Laws of California,and agree that if I should Become subject to the workers'compensation provisions of Section 3700 o t .bo ode,I shall forthwith comply with those provisions. ❑I, as owner of the property, or my employees with wages as their sole p y p I compensation,will do the work,and the structure is not intended or offered for X21 i ‘"1 sale(Section 7044,Business and Professions Code:The Contractors License Date Signature Law does not apply to an owner of property who builds or improves thereon, or who does such work himself or herself or through his or her own employees,provided that such improvements are not intended or offered for WARNING: Failure to secure Workers'Compensation coverage is unlawful, sale.If,however,the building or improvement is sold within one(1)year of an&shall subject an employer to criminal penalties and civil fines up to one completion,the owner-builder will have the burden of proving that he or she hundred thousand,dollars($100,000),in addition;to the cost of compensation, did not build or improve for the purpose of sale). damages.as provided for in Section 3706 of the,Labor Code, interest, and attorney's,fees. ❑I, as owner of the property, am exclusively contracting with licensed contractors to construct the project(Section 7044,Business and Professions Code:The Contractors License Law does not apply to an owner of property CONSTRUCTION LENDING AGENCY who builds or improves thereon,and who contracts for such projects with a I hereby affirm under penalty of perjury that there is a construction lending agency contractor(s)licensed pursuant to the Contractors License Law). for the performance of the work for which this permit is issued (Section 3097, Civil Code). ❑ I am exempt under Section 7044,Business and Professions Code,for this reason: Lender's Name Date Signature Lender's Address IMPORTANT: APPLICATION IS HEREBY MADE TO THE BUILDING OFFICIAL FOR A PERMIT SUBJECT TO THE CONDITIONS AND RESTRICTIONS SET FORTH ON THIS APPLICATION AND THE FOLLOWING: 1. The City's approved plans and permit inspection card must remain on the job site for use by City inspection personnel. 2. Final inspection of the work authorized by this permit is required.A Certificate of Occupancy must be obtained prior to use and occupancy of new buildings and structures. 3. Per South Coast Air Quality Management District(AQMD)regulations,renovation and remodeling work that results in the removal,stripping,or altering of asbestos containing materials requires an asbestos survey and removal prior to disturbing the asbestos.Please contact AQMD at(909) 396-2000 for further information. ' Name 10\11 C Q `( UI1 fl Title PRINT N ME certify that I have read this application and state that the above information is correct and that I am the owner or duly authorized agent of the owner. I agree to comply with all City ord' ances and State Laws relating to building construction. I hereby authorize representatives of the City of Arcadia to enter upon the ove- ' .,j�oned property for inspection purposes. �� �/� Signature Date Lt' 27- I7 ..4%=&-, Development Services Department I:1 41 240 West Huntington Drive,Post Office Box 60021 PERMIT NO. Arcadia,CA 91066-6021 BOO-056-909 City of (626)574-5416,Fax(626)447-9173 ArcadiaPermit Type: Fire PROJECT TRACT NO. LOT NO. APPLICATION DATE ISSUED BY PRINT DATE PERMIT STATUS 5/18/2017 CM 11:44 5/25/2017 Issued / ADDRESS NO. Dir.Prefix Street Name Street Suffix UNIT BLG ASSESSORS PARCEL NO. GEO CODE 400 S Baldwin Ave T-387 OWNER MAILING ADDRESS Westfield Corporation,Inc. 11601 Wilshire Blvd. 12th Floor PHONE NO. Plan Chk#: 17-156 Los Angeles, CA 90025- EMAIL ADDRESS: APPLICANT MAILING ADDRESS Building Electronic Controls Inc. PHONE NO. EMAIL ADDRESS: CONTRACTOR/PROFESSIONAL MAILING ADDRESS Building Electronic Controls Inc. 2246 Lindsay Way PHONE NO. FAX NO. Glendora, CA 91740 EMAIL ADDRESS: License No. 729905 Type: C Expires: 11/30/2018 12:01 TENANT MAILING ADDRESS Bath&Body Works PHONE NO. FAX NO. DESCRIPTION fire alarms for Bath&Body Works Construction Type UOM II of Units Value Construction Type UOM 8 of Units Value Value Value 9,750.00 $9,750.00 OCCUPANCY: Fire Sprink/Alm TOTAL VALUATION: $9,750.00 , QTY UOM DESC AMT AMT PAID ACCT QTY UOM DESC AMT AMT PAID ACCT 17.00 each fire alarm pc 2 700.00 700.00 01-3109 1.00 Flat Fire'Issue Auto 44.35 44.35 01-3112 each Fire Permit 237.25 237.25 01-3112 , 1.00 each SWMF 2 Auto 1.00 1.00 88-3027 Total Fees: $982.60 Balance Due: $0.00 Paid Today: $282.60 This permit/plan review expires by time limitation and becomes null and void if the work authorized by the 'eceip :: s'I permit is not commenced within 180 days from the date of issuance or if the permit is not obtained within 180 days from 01-3112 281.60 the date of plan submittal.This permit expires and becomes null and void if any work authorized by this permit 88-3027 1.00 is suspended or abandoned for 180 consecutive days or if no progressive work has been verified by a City of Arcadia building inspector for a period of 180 consecutive days. CALLS FOR INSPECTION INSPECTORS'OFFICE HOURS Requests for inspection should be made at least Monday-Thursday Friday one(1)business day in advance of the inspection 7:30 a.m.to 8:30 a.m. 7:30 a.m.to 8:30 a.m. by telephone at(626)574-5416 for onsite work. 4:00 p.m.to 5:30 p.m. 4:00 p.m.to 4:30 p.m. (Closed on alternate Fridays) of AR Ai e" Rry9d i PERMIT/PLAN REVIEW APPLICATION ''II V:\ '1--' 0gr-4 IFEEM �{a Development Services Department,240 West Huntington Drive,Post Office Box 60021 o,,Y at 0. Arcadia, CA 91066-6021, (626) 574-5416,Fax (626) 447-9173 City of Arcadia LICENSED CONTRACTOR'S DECLARATION WORKERS'COMPENSATION DECLARATION •it:1 I hereby affirm under penalty of perjury that I am licensed under provisions of I hereby affirm under penalty of perjury one of the following: Chapter 9(commencing with Section 7000,of Division 3 of the Business and Professions Code,and my license is in full force and effect. ❑ I have and will maintain a certificate of consent to self-insure for workers' License Class p Ill l3U/1 compensation, providedby G�� License No. Z � x . Date as for Section 3700 of the Labor Code, for the Signature of Contractor (AA • y A performance of the work for which this permit is issued. OWNER-BUILDER DECLARATION I have and will maintain workers'compensation insurance,as required by Section IDI hereby affirm under penalty of perjury that I am exempt from the Contractors TTVV3700 of the Labor Code,for the performance of the work for which this permit License Law for the following reason(Section 7031.5,Business and Professions is issued.My (]wQo�rQkers'compensation insurance carrier and policy numbers are: Code.Any city or county which requires a permit to construct,alter,improve, Carrier �C_• "''r A, kl\NI `ItA VaY'C demolish,or repair any structure,prior to its issuance,also required the applicant a v\1 G ok r-0v \o--e,---,Th for such permit to file a signed statement that he or she is licensed pursuant to the Policy Number V v provisions of the Contractors License Law(Chapter 9(commencing with Section (This section need not be completed if the permit is for one hundred dollars or less) 7000).of Division 3 of the Business and Professions Code) or that he or she is exempt there from and the basis for the alleged exemption. Any violation of ❑ I certify that in the performance of the work for which this permit is issued,I shall Section 7031.5 by any applicant for a permit subjects the applicant to a civil not employ any person in any manner so as to become subject to the workers' penalty of not more than five hundred dollars($500)): compensation Laws of California,and agree that if I should become subject to the workers'compensation provisions of Section 3700 of the Labor Code,I shall ❑I, as owner of the property, or my employees with wages as their sole forthwith comply with those provisions. compensation,will do the work,and the structure is not intended or offered for sale(Section 7044,Business and Professions Code:The Contractors License DateI 2.. /V•1 GJ SignaturedC%�_ cy ��I,� �i Law does not apply to an owner of property who builds or improves thereon, 1 or who does such work himself or herself or through his or her own employees,provided that such improvements are not intended or offered for WARNING: Failure Co secure Workers'Compensation coverage is unlawful, sale.If,however,the building or improvement is sold within one(1)year of and shall subject an employer to criminal penalties and civil fines up to one completion,the owner-builder will have the burden of proving that he or she hundred thousand dollars($100,000),in addition to the cost of compensation, did not build or improve for the purpose of sale). damages as provided for in Section 3706 of the Labor Code, interest, and attorney's fees. ❑I, as owner of the property, am exclusively contracting with licensed contractors to construct the project(Section 7044,Business and Professions Code:The Contractors License Law does not apply to an owner of property CONSTRUCTION LENDING AGENCY who builds or improves thereon,and who contracts for such projects with a I hereby affirm under penalty of perjury that there is a construction lending agency contractor(s)licensed pursuant to the Contractors License Law). for the performance of the work for which this permit is issued (Section 3097, Civil Code). ❑ I am exempt under Section 7044,Business and Professions Code,for this reason: Lender's Name Date Signature Lender's Address IMPORTANT: APPLICATION IS HEREBY MADE TO THE BUILDING OFFICIAL FOR A PERMIT SUBJECT TO THE CONDITIONS AND RESTRICTIONS SET FORTH ON THIS APPLICATION AND THE FOLLOWING: 1. The City's approved plans and permit inspection card must remain on the job site for use by City inspection personnel. 2. Final inspection of the work authorized by this permit is required.A Certificate of Occupancy must be obtained prior to use and occupancy of new buildings and structures. 3. Per South Coast Air Quality Management District(AQMD)regulations,renovation and remodeling work that results in the removal,stripping,or altering of asbestos containing materials requires an asbestos survey and removal prior to disturbing the asbestos.Please contact AQMD at(909)396-2000 for further information.Name V) -\".°A\ �PRAdk Title y - %3 \k) Vitsl rcilet I certify that I have read this application and state that the above information is correct and that I am the owner or duly authorized agent of the owner. I agree to comply with•all City ordinances and State Laws relating to building construction. I hereby authorize representatives of the City of Arcadia to enter upon the above-mentioned property for inspection purposes. J Signature �`J Date '/ZJ/1 i v , Development Services Department West Huntington Drive,Post Office Box 60021 PERMIT NO. BOO-056-909 ��' Arcadia,CA 91066-6021 City of (626)574-5416,Fax(626)447-9173 Permit Type: Fire Arcadia YP • PROJECT TRACT NO. LOT NO. APPLICATION DATE ISSUED BY PRINT DATE PERMIT STATUS 5/18/2017 CM 10:05 5/18/2017 Issued ADDRESS NO. Dir.Prefix Street Name Street Suffix UNIT BLG ASSESSORS PARCEL NO. GEO CODE 400 S Baldwin Ave T-387 OWNER MAILING ADDRESS Westfield Corporation, Inc. 11601 Wilshire Blvd. 12th Floor PHONE NO. Plan Chk#: 17-156 Los Angeles,CA 90025- EMAIL ADDRESS: APPLICANT MAILING ADDRESS Building Electronic Controls Inc. PHONE NO. EMAIL ADDRESS: , CONTRACTORIPROFESSIONAL MAILING ADDRESS Building Electronic Controls Inc. 2246 Lindsay Way PHONE NO. FAX NO. Glendora, CA 91740 EMAIL ADDRESS: License No. 729905 Type: C Expires: 11/30/2018 12:01 TENANT MAILING ADDRESS Bath&Body Works PHONE NO. FAX NO. DESCRIPTION fire alarms for Bath&Body Works Construction Type UOM #of Units Value Construction Type UOM #of Units Value Value Value 9,750.00 $9,750.00 OCCUPANCY: Fire Sprink/Alm TOTAL VALUATION: $9,750.00 QTY UOM DESC AMT AMT PAID ACCT QTY UOM DESC AMT AMT PAID ACCT 17.00 each fire alarm pc 2 700.00 700.00 01-3109 1.00 Flat Fire Issue Auto 44.35 01-3112 each Fire Permit 237.25 01-3112 1.00 each SWINT'2 Auto 1.00 88-3027 Total Fees: $982.60 Balance Due: $282.60 Paid Today: $700.00 This permit/plan review expires by time limitation and becomes null and void if the work authorized by the Receipt#: 116814 permit is not commenced within 180 days from the date of issuance or if the permit is not obtained within 180 days from 01-3109 700.00 the date of plan submittal.This permit expires and becomes null and void if any work authorized by this permit is suspended or abandoned for 180 consecutive days or if no progressive work has been verified by a City of Arcadia building inspector for a period of 180 consecutive days. CALLS FOR INSPECTION INSPECTORS'OFFICE HOURS Requests for inspection should be made at least Monday-Thursday Friday one(1)business day in advance of the inspection 7:30 a.m.to 8:30 a.m. 7:30 a.m.to 8:30 a.m. by telephone at(626)574-5416 for onsite work. 4:00 p.m.to 5:30 p.m. 4:00 p.m.to 4:30 p.m. (Closed on alternate Fridays) of ARC ti 4�y�oRyy9 I PERMIT/PLAN REVIEW APPLICATION il 00 ,j` Development Services Department,240 West Huntington Drive,Post Office Box 60021 Arcadia, CA 91066-6021, (626) 574-5416,Fax (626) 447-9173 City of Arcadia LICENSED CONTRACTOR'S DECLARATION WORKERS'COMPENSATION DECLARATION ❑ I hereby affirm under penalty of perjury that I am licensed under provisions of I hereby affirm under penalty of perjury one of the following: Chapter 9(commencing with Section 7000,of Division 3 of the Business and Professions Code,and my license is in full force and effect. ❑ I have and will maintain a certificate of consent to self-insure for workers' License Class License No. Exp. Date compensation, as provided for by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. Signature of Contractor OWNER-BUILDER DECLARATION EllI have and will maintain workers'compensation insurance,as required by Section 1:1I hereby affirm under penalty of perjury that I am exempt from the Contractors 3700 of the Labor Code,for the performance of the work for which this permit License Law for the following reason(Section 7031.5,Business and Professions is issued.My workers'compensation insurance carrier and policy numbers are: Code.Any city or county which requires a permit to construct,alter,improve, Carrier demolish,or repair any structure,prior to its issuance,also required the applicant for such permit to file a signed statement that he or she is licensed pursuant to the Policy Number provisions of the Contractors License Law(Chapter 9(commencing with Section (This section need not be completed if the permit is for one hundred dollars or less) 7000)of Division 3 of the Business and Professions Code)or that he or she is exempt there from and the basis for the alleged exemption. Any violation of ❑ I certify that in the performance of the work for which this permit is issued,I shall Section 7031.5 by any applicant for a permit subjects the applicant to a civil not employ any person in any manner so as to become subject to the workers' penalty of not more than five hundred dollars($500)): compensation Laws of California,and agree that if I should become subject to the •workers'compensation provisions of Section 3700 of the Labor Code,I shall ❑I, as owner of the roe forthwith comply with those provisions. property,rty, or my employees with wages as their sole compensation,will do the work,and the structure is not intended or offered for sale(Section 7044,Business and Professions Code:The Contractors License Date Signature Law does not apply to an owner of property who builds or improves thereon, or who does such work himself or herself or through his or her own employees,provided that such improvements are not intended or offered for WARNING Failureeto secure Workers'Compensationcoverage is unlawful, sale.If,however,the building or improvement is sold within one(1)year of and shall subject an employer to criminal penalties and civil fines up to one completion,the owner-builder will have the burden of proving that he or shehundred thousand dollars($100000),in additionto the cost of compensation, did not build or improve for the purpose of sale). damages as provided for in Section 3706 of the Labor°Codeinterest, and attorney's fees. - ❑I, as owner of the property, am exclusively contracting with licensed contractors to construct the project(Section 7044,Business and Professions Code:The Contractors License Law does not apply to an owner of property CONSTRUCTION LENDING AGENCY who builds or improves thereon,and who contracts for such projects with a I hereby affirm under penalty of perjury that there is a construction lending agency contractor(s)licensed pursuant to the Contractors License Law). for the performance of the work for which this permit is issued (Section 3097, Civil Code). ❑ I am exempt under Section 7044,Business and Professions Code,for this reason: Lender's Name Date Signature Lender's Address IMPORTANT: APPLICATION IS HEREBY MADE TO THE BUILDING OFFICIAL FOR A PERMIT SUBJECT TO THE CONDITIONS AND RESTRICTIONS SET FORTH ON THIS APPLICATION AND THE FOLLOWING: 1. The City's approved plans and permit inspection card must remain on the job site for use by City inspection personnel. 2. Final inspection of the work authorized by this permit is required.A Certificate of Occupancy must be obtained prior to use and occupancy of new buildings and structures. 3. Per South Coast Air Quality Management District(AQMD)regulations,renovation and remodeling work that results in the removal,stripping,or altering of asbestos containing materials requires an asbestos survey and removal prior to disturbing the asbestos.Please contact AQMD at(909)396-2000 for further information. Name4y\dO\.XJ¼S( ' �C� Title ' AA __`� PRINT N I certify that I have read this application and state that the above information is correct and that I am the owner or duly authorized agent of the owner. I agree to comply with all City ordinances and State Laws relating to building construction. I hereby authorize representatives of the City of Arcadia to enter upon the above-•. •ntion•: 1 roperty for inspection purposes. 1 Signature,Al W� ``` �� Date i/ 9 ! n 1 .•-fiLftk, Development Services Department t1 hA 240 West Huntington Drive,Post Office Box 60021 PERMIT NO. \,-- Arcadia, CA 91066-6021 BOO-057-662 City of (626)574-5416,Fax(626)447-9173 Arcadia Type:Permit T e Fire PROJECT TRACT NO. LOT NO. APPLICATION DATE ISSUED BY PRINT DATE PERMIT STATUS 8/23/2017 EP 8:31 8/23/2017 Issued ADDRESS NO. Dir.Prefix Street Name Street Suffix UNIT BLG ASSESSORS PARCEL NO. GEO CODE 400 S Baldwin Ave T-387 OWNER MAILING ADDRESS Westfield Corporation, Inc. 11601 Wilshire Blvd. 12th Floor PHONE NO. Plan Chk#: OTC Los Angeles, CA 90025- EMAIL ADDRESS: APPLICANT MAILING ADDRESS Hydro-Matic Fire Protection PHONE NO. EMAIL ADDRESS: CONTRACTOR/PROFESSIONAL MAILING ADDRESS Hydro-Matic Fire Protection 1161 Rosedale Avenue PHONE NO. (81 8)247-9812 FAX NO. Glendale, CA 91208 EMAIL ADDRESS: License No. 718393 Type: C-16 Expires: 6/30/2019 12:00: TENANT MAILING ADDRESS Bath Body Works PHONE NO. FAX NO. DESCRIPTION FIRE SPRINKS FOR BATH BODY WORKS.66 HEADS Construction Type UOM #of Units Value Construction Type UOM #of Units Value Value Value 7,000.00 $7,000.00 OCCUPANCY: Fire Sprink/AIm TOTAL VALUATION: $7,000.00 QTY DOM DESC AMT AMT PAID ACCT QTY IIOM DESC AMT AMT PAID ACCT 66.00 each sprinkler pck 700.00 700.00 01-3109 1.00 Flat Fire Issue Auto 44.35 44.35 01-3112 each Fire Permit 187.15 187.15 01-3112 1.00 each SWMF 2 Auto 1.00 I 00 88-3027 Total Fees: $932.50 Balance Due: $0.00 Paid Today: $932.50 This permit/plan review expires by time limitation and becomes null and void if the work authorized by the Receipt#: 117707 - permit is not commenced within 180 days from the date of issuance or if the permit is not obtained within 180 days from 01-3109 700.00 the date of plan submittal.This permit expires and becomes null and void if any work authorized by this permit 01-3112 231.50 is suspended or abandoned for 180 consecutive days or if no progressive work has been verified by a City of 88-3027 1.00 Arcadia building inspector for a period of 180 consecutive days. CALLS FOR LNSPECTION INSPECTORS'OFFICE HOURS //00 - Requests for inspection should be made at least Monday-Thursday Friday one(1)business day in advance of the inspection 7:30 a.m.to 8:30 a.m. 7:30 a.m.to 8:30 a.m. by telephone at(626)574-5416 for onsite work. 4:00 p.m.to 5:30 p.m. 4:00 p.m.to 4:30 p.m. (Closed on alternate Fridays) 4_. 'u'y9. °~ 1 PERMIT/PLAN REVIEW APPLICATION %, : 1fl. Development Services Department,240 West Huntington Drive,Post Office Box 60021 o° j, Arcadia, CA 91066-6021, (626) 574-5416,Fax (626) 447-9173 @�ot,y orH City of Arcadia LICENSED CONTRACTOR'S DE'LARATION WORKERS'COMPENSATION DECLARATION ❑ I hereby affirm under penalty of perjury t I am licensed under provisions of I hereby affirm under penalty of perjury one of the following: Chapter 9(commencing with Section 70%`1,of Division 3 of the Business and Professions Code,and/m/�y license i 'n` License Class� ,/11,4 ce and effect. DI I have and will maintain a certificate of consent to self-insure for workers'C--1(� c s • Exp. Date --312 '1 compensation, as provided for by Section 3700 of the Labor Code, for the / / � performance of the work for which this permit is issued. Signature of Contractor —1111111111111kOWNER-BUILDER DE LARATION ❑ I have and will maintain workers'compensation insurance,as required by Section 0 I hereby affirm under penalty of perjury that I am exempt from the Contractors 3700 of the Labor Code,for the performance of the work for which this permit License Law for the following reason(Section 7031.5,Business and Professions is issued.My workers'compensation insurance carrier and policy numbers are: Code.Any city or county which requires a permit to construct,alter,improve, Carrier -1- pis 0 D demolish,or repair any structure,prior to its issuance,also required the applicant for such permit to file a signed statement that he or she is licensed pursuant to the olicy Number provisions of the Contractors License Law(Chapter 9(commencing with Section This section need not be completed if the permit is for one hundred dollars or less) 7000)of Division 3 of the Business and Professions Code) or that he or she is exempt there from and the basis for the alleged exemption. Any violation of ❑ certify that in the performance of the work for which this permit is issued,I shall Section 7031.5 by any applicant for a permit subjects the applicant to a civil not employ any person in any manner so as to become sub'ect t• the workers' penalty of not more than five hundred dollars($500)): compensation Laws of California,and agree that if I shou. •- o e subject to the workers'compensation provisions of Section 3 10 •' ,e L..or Code,I shall forthwith comply rovision ' ❑I, as owner of the property, or my employees with wages as their sole p y with those p s. compensation,will do the work,and the structure is not intended or offered for sale(Section 7044,Business and Professions Code:The Contractors License Date—03— "1 Signature Law does not apply to an owner of property who builds or improves thereon, or who does such work himself or herself or through his or her own employees,provided that such improvements are not intended or offered for WARNING: Failure to secure Workers'Compensation coverage is unlawful, sale.If,however,the building or improvement is sold within one(1)year of and shall subject an employer to criminal penalties,and civil fines up to one completion,the owner-builder will have the burden of proving that he or she hundred thousand dollars($100,000),in addition to the cost of compensation, did not build or improve for the purpose of sale). damages as provided for in Section 3706 of the Labor Code, interest, and attorney's fees. ❑I, as owner of the property, am exclusively contracting with licensed contractors to construct the project(Section 7044, Business and Professions Code:The Contractors License Law does not apply to an owner of property CONSTRUCTION LENDING AGENCY who builds or improves thereon,and who contracts for such projects with a I hereby affirm under penalty of perjury that there is a construction lending agency contractor(s)licensed pursuant to the Contractors License Law). for the performance of the work for which this permit is issued (Section 3097, Civil Code). ❑ I am exempt under Section 7044,Business and Professions Code,for this reason: Lender's Name Date Signature Lender's Address IMPORTANT: APPLICATION IS HEREBY MADE TO THE BUILDING OFFICIAL FOR A PERMIT SUBJECT TO THE CONDITIONS AND RESTRICTIONS SET FORTH ON THIS APPLICATION AND THE FOLLOWING: 1. The City's approved plans and permit inspection card must remain on the job site for use by City inspection personnel. 2. Final inspection of the work authorized by this permit is required.A Certificate of Occupancy must be obtained prior to use and occupancy of new buildings and structures. 3. Per South Coast Air Quality Management District(AQMD)regulations,renovation and remodeling work that results in the removal,stripping,or altering of asbestos containing materials requires an asbestos survey and removal prior to disturbing the asbestos. Please contact AQMD at(909)396-2000 for ' further information. ame . 1400 _. V 19 4 A, r 0 Title C.1QL PC I ,. PRINT NAM I certify that I have re. I cation nd tate that the above information is correct and that I am the owner or duly authorized agent of the owner. I agree to compl hty ordinances d State Laws relating to building construction. I hereby authorize representatives of the City of Arcadia to ente,zzil -mentioned pro erty for inspection purposes. Sgnature / Date e-.7 -,.._.. 1 --t GB T.A.B. GREEN BUILDING TEST & BALANCE CO. ` 663 S. RANCHO SANTE FE RD_, SUITE #203 SAN MARCOS, CA 92078 PH#_ 760-533-7171 FAX#: 760-842-1.420 HVAC Systems Test And Balance Report PROJECT NAME: BATH & BODY WORKS / WESTFIELD SANTA ANITA PROJECT LOCATION: 400 SOUTH BALDWIN AVE. SPACE # A-12 ARCADIA, CA. 91007 The data presented in this report is an exact record of system performance and was obtained in accordance with NEBB standard procedures. Any variances from design quantities which exceed NEBB tolerances are noted throughout this report The system have been tested and balanced and final adjustments have been made in accordance with NEBB "Procedural Standards for Testing, Adjusting, Balancing of Environmental Systems" and the project specifications. Job Number: 917-43 • r ma re Pir OR 2 Date: SEPT.22, 2017 PATRICK DRAYTON CERTIFICATION z 3606 TAB Engineer: Patrick Drayton Exp.3137/98 PATRICK DRAYTON DIRECTOR OF OPERATIONS BUILDING COMMISSIONING TESTING-ADJUSTING-BALANCING CA LIC. C-20#805186 PATRICK DRAYTON GB DIRECTOR OO MIOPSSI TIONS T, B. BUILDING COMMISSIONING f GREEN BUILDING TESTING-ADJUSTING•BALANCING TEST�p �p S EJ 9. & BALANCE CO. 663 S.RANCHO SANTA FE RD.,SUITE#203 SAN MARCOS,CA 92078 • PI-UP.760-533-7171 FAX#760-842-1420 ABBREVIATIONS L _ ACT - ACTUAL, AK - FREE AREA FACTOR CD CEILING DIFFUSER - CEG - CEILING EXHAUST FIEGISTEE CFM - CUBIC FEET PER MINUTE CRR CEILING RETURN REGISTER - D-B- - DRY MKS DO - DIRECT DRIVE Dt4L - DATA t4OT LISTED ECG - EGG CRATE GRILL ENT ENTERING - ESP - EXTERNAL STATIC PRESSURE FIS - , FLOW HOOD C I imiscns SO FPM AND AK FACTORS ARE (O ) i - FEET PER MIWJ)TE GPM - GALLONS PER MINUTE H.P. - HORSEPOWER UN - LIAR . LT LIGHT TETOEIGITERS - NA - NOTAPPLICABLEntiO ACAS KM - NOT MEASURED NS - NOT SPECIFIED NYL - NOT VALID LOCATION FOR TESTING OSA. - OUTSIDE AUR PA PRESSURE DROP - R.AL - RE1VRN AIN REQ - REQUIRED RPM - RETiournows PER N J1E SA. - SUPPLY AIR SWS - MDE WALL SUPPLY T.DJI. - TOTAL DEAD HEAD W_B - WET BULB WG- - WATER GSE CA_LIC-C-20#805186 • GB TAB. I GREEN BUILDING TEST 6- BALANCE CO. ACE et 663 S_ RANCHO SANTE FE RD., SUITE#203 SAN MARCOS, CA 92078 PH#: 760-533-7171 FAX#: 760-842-1420 Date: SEPT. 22,2017 Job Name: BATH&BODY WORKS/ SANTA ANITA FASHION PARK/#Al2 Page: 1 FAN TEST Fan Name AHU#1 AHU#2 Service SALES FLOOR , STOCK ROOM Location ABOVE CEILING ABOVE CEILING Manufacturer TRANE TRANE Model Number CWE120E4RBBA Q0R889A Serial Number 172513BEBA • K17E35159 DESIGN ACTUAL DESIGN ACTUAL DESIGN ACTUAL C TOTAL-FAN 4200 4200 1100 1134 F TOTAL-OUTLETS 4200 4200 1100 1134 M RETURN AIR 3650 3667 995 998 OUTSIDE AIR 550 533 105 I 136 S P DISCHAGE N.S. 0.58 N.S. 0.64 T R SUCTION N.S. 0.39 N.S. 0.22 A E TOTAL S.P. N.S. 0.97 N.S. 0.86 T S EXTERNL S.P. 1 I 0.97 I 1 I 0.86 MANUFACTURER/FR MARATHON MARATHON M HORSEPOWER 3 _ I 3 I 1 I 1 F 0 VOLTAGE 460 I 462- 460- 461 I 460 I 458- 460- 461 A T PHASE 3 I 3 I 3 I 3 N 0 AMPERAGE 4.6 / 4.4 4.2 4.4 2.3 / 2.2 2.1 2.3 _ R RPM/SPEED N.S. 1765 N.S. r 1755 SERVICE FACTOR 1.15 1.15 1.15 1.15 MTR SHEAVE SIZE 1-VP5OX 7/8" 1-VP4OX 7/8" D • %CLOSED 100% 55% R FAN SHEAVE SIZE 1-AF80 X 7/8" 1-AF3OX 3/4" I FAN RPM N.S. 1103 N.S. 1745 V BELT SIZE/#OF 1-BX52 1-A36 E CENTER TO CENTER 19" 15" TRAVEL IN/OUT 1" 2" 3" 1" NOTES: PATRICK DRAYTON DIRECTOR OF OPERATIONS BUILDING COMMISSIONING READINGS BY: PATRICK DRAYTON TESTING-ADJUSTING-BALANCING ritl.4. IR , CA LIC.C-20#805186 GB . T.A.B.I GREEN BUILDING JOB NAME: BATH & BODY WORKS / ARCADIA • AHU#1 TEST& BALANCE CO. 663 S.RANCHO SANTE FE RD.,SUITE#203 SAN MARCOS,CA 92078 PH#: 760-533-7171 FAX#:760-842-1420 AIR DISTRIBUTION TEST • ZONE NAME TERMINAL EFFECT AREA DESIGN ACTUAL % NOTES # TYPE SIZE FPM CFM FPM CFM AHU#1 SUPPLY AIR SALES FLOOR S-1 C.D. 12"X12" F.H. F.H. 185 F.H. 175 SALES FLOOR 5-2 C.D. 12"X12" F.H. F.H. 185 F.H. 180 • SALES FLOOR S-3 C.D. 12"X12" F.H. F.H. 185 F.H. 175 SALES FLOOR S-4 C.D. 12"X12" F.H. F.H. 185 F.H. 190 SALES FLOOR S-5 C.D. 12"X12" F.H. F.H. 185 F.H. 175 SALES FLOOR S-6 'C.D. 24"X24" F.H. F.H. 240 F.H. 250 SALES FLOOR 5-7 C.D. 24"X24" F.H. F.H. 240 F.H. 245 SALES FLOOR 5-8 C.D. 24"X24" F.H. F.H. 275 F.H. 280 SALES FLOOR S-9 C.D. 24"X24" F.H. F.H. 275 F.H. 285 SALES FLOOR S-10 C.D. 24"X24" F.H. F.H. 305 F.H. 300 SALES FLOOR S-11 C.D. 24"X24" F.H. F.H. 305 F.H. 300 SALES FLOOR S-12 C.D. 24"X24" F.H. F.H. 240 F.H. 250 SALES FLOOR S-13 C.D. 24"X24" F.H. F.H. 240 F.H. 245 SALES FLOOR S-14 C.D. 24"X24" F.H. F.H. 275 F.H. 275 SALES FLOOR S-15 C.D. 24"X24" F.H. F.H. 275 F.H. 275 SALES FLOOR S-16 C.D. 24"X24" F.H. F.H. 300 F.H. 310 SALES FLOOR S-17 C.D. 24"X24" F.H. F.H. 305 F.H. 290 TOTAL 4200 4200 100% AHU#1 RETURN AIR SALES FLOOR R-1 O.D. 14"X48" 4.7 777 3650 780 3667 TOTAL 3650 3667 100% NOTES: - PATRICK DRAYTON DIRECTOR OF OPERATIONS BUILDING COMMISSIONING READINGS BY: PATRICK DRAYTON TESTING-ADJUSTING-BALANCING Hf: On CA LIC.C-20#805186 GB TAB. GREEN BUILDING JOB NAME: BATH& BODY WORKS / ARCADIA AHU#2 TEST& BALANCE CO. 663 S. RANCHO SANTE FE RD.,SUITE#203 SAN fv1ARCOS, CA 92078 • PH#: 760-533-7171 FAX#:760-842-1420 AIR DISTRIBUTION TEST ZONE NAME TERMINAL EFFECT AREA DESIGN ACTUAL NOTES # TYPE SIZE FPM CFM FPM CFM AHU#2 SUPPLY AIR STOCK ROOM S-1 SWS 10"X8" 0.53 283 150 283 150 STOCK ROOM S-2 SWS 10"X8" 0.53 283 150 295 156 STOCK ROOM S-3 SWS 10"X8" 0.53 283 150 300 159 STOCK ROOM S-4 SWS 10"X8" 0.53 283 150 300 159 STOCK ROOM S-5 C.D. 24"X24" F.H. • F.H. 500 F.H. 530 TOTAL 1100 1134 103% AHU#2 • RETURN AIR STOCK ROOM R-1 O.D. 12"X12" 1 995 995 998 998 TOTAL 995 998 -100% NOTES: PATRICK DRAYTON DIRECTOR OF OPERATIONS BUILDING COMMISSIONING READINGS BY: PATRICK DRAYTON TESTING-ADJUSTING-BALANCING CA LIC.C-20#805186 DEPARTMENT OF BUILDING AND SAFETY /w 7 / A C `F I O n CITY OF X0964 ; ���SPECIAL INSPECTIONS I 44444 Buena Vista Way COUNTY OF Lancaster,CA 93536 1 (661)202-4072 Office INSPECTION REPORT BUILDING PERMIT NO. JOB NO. DATE: /-/7 i JOB NAME/ADDRESS1, Ara o r )' A , v Df� . ♦ ,� ,J A f L- Al :i. c/ '• - /0O GENERAL CONTRACTOR/ADDRESS L. cwl4. /U n) J ARCHITECT/ENGINEER ADDRESS ' ir0 o i` i. _L ' JJ '7c . i ._,/ ",) _Z_ J SUBCONTRACTOR/ADDRESS NP L d.5_�, WELDER/RECEIPT NO. WELDER/RECEIPT NO. WELDING _REINFORCED CONCRETE _ P.T.CONCRETE DRILLED-IN ANCHORS El H.S.BOLT ASSEMBLY FIREPROOFING _STRUCTURAL MASONRY EPDXY INJECTION ®OTHER y DESCRIPTION OF WORK 'e S _(�_ ..1___ L _ /-1T Dl-�°L f> ��<L9f/L-A6Z..14-S vj-- Amman" ' r= - P f%9 Al ' ' /id` •r (%'.77./15 -7----Z • 4 7- /JC//O l/-/-7-/-% c2` .-41)/if.-/-1 f 0 / is f'-ALI/1/f.i c, S"-. v r L,F ��fI.�AiE./ _C77//e/ 6/ /g2.N,S- --.. .--re-:-.C. • --L-s./L .4 /9/7 ,6i__,--- ,L; /` o.,,.//!�y( ,_Sf,ryss2,9/j n CONCRETE GROUT MORTAR BLOCK PRISMS DENSITY • _ •- •_ _ .. _ _ ONDAY TUESDAY WEDNESDAY THURSDAY FRIDAY ATURDAY _ SUNDAY DAILY HOURS/TERMS: f' All inspections based on a 4 hour minimum for each trade inspected,and over 4 hours is an 8 hour minimum. In addition,any inspections extending past noon will be an 8 hour minimum.Weekends,holidays,and hours between 6 pm-6 am are paid at time and a halt There is a 4-hour minimum charge if job is cancelled for any reason,including rain,and inspector is not notified in advance.Testing fees vary and will be indicated on invoice. ATTORNEY FEES: If any action at law or in equity is brought to enforce or interpret the terms of this Contract,the prevailing party shall be entitled to reasonable attorney's fees,costs and necessary disbursements in addition to any other relief to which such party may be entitled. CERTIFICATE OF COMPLIANC INSPECTOR'S NAME fie eOc_ Aoi) INSPECTOR'S SIGNATURE '/_________ INSPECTOR'S ID/LIC.NO.-1-•C•c 402 776 r,3 has been filed and it states that the above work to the best of his/her knowledge complies with the provisions of the Uniform Building Code and meets approved plans and specifications. APPROVED/AUTHORIZED BY: Project Superintendent White=Office Yellow=Jobsite Pink=Inspector Structural Calculations For: Bath and Body Works — Santa Anita Fashion Park Arcadia, CA 2016-1172 2/8/17 CS1 &' Working Drawing Review roved ❑ Approved as.Noted ❑ Resubmit • These drawings have been reviewec fo-general design intent only. All actuzal r,old cor,uitions e:e r:c uired to be verified by the Tenant's Architect and/or Contractor. Tenant is responsible for complying with all government regulations. One(1)copy of this landlord stamped set of drawings is Prepared by: requir be kept on the job site at all times. • • Signed Date • • Thorson • Baker + Associates CONSULTING ENGINEERS , •l • • ioESSioN F 71921 .01, 0.1 • FOF , La 4 s e ZZ DEC 312011. • Table of Contents Design Criteria DC1 Storefront Design SF1 . ' AHU Support Desing AHU1 • • :r; • -� tom. , Tenant Fit-Out Design Criteria ,r Project No 2016-1172 Date. 5-Jan-17 Project. BBW-Santa Anita Prepared 91 JCP "iorson-.Baker+Associates Project Site Arcadia,CA Principal DLN I__:D N S U L T I N G ENGINEERS copy:4h12010 **Note: Enter Project Information On Design Criteria Tab Client: Shremshock Contact:. Stacey Bower D C-- 1 Tenant: BBW an����a:t4f= sj�n,:, etc.+��L�c ���k�3r �s-`F i3BiS�`-�: .Af,�v3A� &"ch:..�'.. � S:r'S�:��`.'"� "�ls�rt.".�tu��tvC Vii, prK ap t Ra r��., Soap 3a aMiNiirateWkhs bulled aildttheratataitaiAl IJc3�r d te» 1'ms rt ;int a a iNtorktatain E Interior ❑ Exterior Level 1 of 2 Slab on Grade ❑ .Supported Floor Storefront ❑ Platform/Loft ❑, Rooftop Unit ❑ Porch, 0 Underhung Unit ❑ Ceiling/Walls Seismic Bracing ❑- , Rolling'Griile Column Support ❑ Floor Slab Infill 'rototypical SIS Package 1 store. Structural Scope includes Storefront Design,AHU Support,and water heater support . i. .� f aW mintev.7ii'xr.vt /2G',k�,.+���^.�'� Yes NA Due Date Comments Prelim riary ❑ ❑ e-Design Site•Observation ❑ - ."instruction Documents E ❑ 2/6 Progress,2/8 100% Specifications ❑ ❑ instruction Phase Site Observa ❑ ❑ f eAWMI5e i X 1 3 E igMtt tU[a1 ' * M :QAD Hbu A cir c Total I . f_ e!!�" OOM.61.�s�' "_ _' x u_`.� : '`IP �> Mr c,11s1a16 ��EE BA,lfi l�fii �i'aiette T , ._ I - 4rahitect Company Name Shremshock Contact Stacey Bower chanical Company Name TBA • ❑ " NA Contact Cory Bittner Electrical Company Name TBA ❑ NA Contact Chris Crowder MOM ������,- '��° ..� g ��M e`tN' j"A�.�e lW iiit l a`�D '_,. KV JM' Q etc �t �1g�. n � _ _��s.'-.�. d�'�n rG ;t? ► �.tatg iTMOMMMV " XIMMBE; 'Oi, Iiency Name City of Arcadia Phone 626-574-5416 'intact Name Don Stockham Fax city,State,Zip Arcadia,CA Website lntacted Bldg Dept ❑ Yes ❑ No Date: Confirmation Sent Aar: m n a •• k{ ! 0°i s 81 'fir .• Sr" r - kY }�. } ti ' ''§ Oi:i r.,,r [�$ ; e� �'`�'i4��s'� :S � ��" .tat '.c ''��,:�.� `�' t, §r �• '` s �kYB ea"a�`* ;� �r� .110�£,Xl� ilding 2016 California Building Code i IBC CIOBC 2015 ❑ ❑ Jther ri icflon Ql Ificallo , AIMMOM. A ' sIWTQW - x pe IIIB =ire Ratings Floors Tenant Fit-Out Design Criteria :Project No 2016-1172 Date 5-Jan-17 CR Project BBW-Santa Anita Prepa-ea i3. JCP 'horson•Baker+Associates ProiectS a Arcadia,CA Principal DLN tII;gCLIENI gugNISHED`II FARM!TION?�Yl;. ni»��`�S 3ki„f ` ','�t.,,'a,SV krr I t?k :.'r h9lf z f„k is :,it . x?,. 5.,".r a'a`Sst. »a'fi:<. .:� f#5. ,a„ ice, �10 O A IIIA 4Urt'.�s s�1 t Jt Y, tr% i of ^YbZ3 R b22 �p ��',z=: 117oS,F a .3`y�e 'sy�q t 4N C tax e 'h ft r m o r �+'3:t#.Sir ni�.,t..,, ..�� .,t..Y"k�s.E�,:n{„F..�;7::I;e$un��}�`:��xYfifd'rr�E. SR tB h ..!.: > -� C t Existing Building Drawings ❑ ❑ Site Survey ❑ 10/25/2016. Space Data Prototype Drawings 0 ❑ 171Sa.02 — }}3o-By Drawings ❑ Lafiftl oI ilti` liii1ie1ne »' :,i�s,�'i Evx t; '.t.YcEWt -t,#+ <>,-,i ,a $,i '? e .-tat aIg` rR:`.f I- .; 'f E;AT„t ,s`i AK.t {E<c,3ir,.EI .siMEI Dan storefront soffit be underhung(gravity)from existing structure? O. Yes 111 No Dan Storefront soffit be braced laterally to the existing structure? 0 _Yes ❑ No s welding to existing structure allowed? ❑,, Yes ❑ No Any requried height clearance? Ortk i TO O ISitigRATiCiN5/UIESGRO C "'iW gi `..r, .:" %x f t ' +.�t 'MiaZfr`W s A, 4ny:expansion joints in existing structure within tenant space? 0 Yes ❑ No. h - ..r. i ...,y,! i •� sir ki`$vr-'Sgat� sw�'�1Y, vF Tams"2 '�`�.- }°.>+ct `is'txu n S�etaS F ':!a`, p § r a�. a n --. .�7.Q't�e�e7�)C^.�[�Stt�,{Io�tDe�iCTie+l•4�.t1�sb...t,^.!2*>va...,r 8r.3u.>-�3 .c..�*:3r 2Fcsla���«ran5ts`vs`_,..id rbf-.Ya;�.k .�m+sk/`�"sn,��ue` ���"'S�E-3�i".'i;�'�'"�u' � 7s a+"�::f-• >� �`.x.a. 't ,. 4 .�. `�'�r�fx���- �s.�a � i..:.r,�sr:;;�TU Roof '. Precast concreteplank floor above space Steel Joist Floor NA Domposite Steel Floor NA Doncrete Floor(*) NA Post Tensioned Concrete Floor(") NA Slab on Grade 4"(Presumed) =oundations(for Exterior Storefronts) NA 3earing Capactiy NA =rest Depth NA Structural Slab on Grade NA Deep Foundations NA :-)If concrete floor verify to make sure that floor is not post tensioned(")If post tensioned floor,discuss with Principal before proceeding Tenant Fit-Out Design Criteria Project No 2016-1172 Date 5-Jan-17 Project BBW-Santa Anita Prepareo Bt JCP Dc- iorson•Baker+Associates Project Site Arcadia,CA • Principal: DLN Cr'rpE�l(� �dRITEpp.Ill��R3#� `��{•�r- ''���tp�,�t3,.,,t`� +.�-_r'6t E -�8 erh'���Y3N`4 r-�3 'l'-'�4 3.,. �'x 3 .^�•p r �'r.� �e^:s'�' . E -ani. i ,lg-Ni k a`s�Au't rc''!TxVV 2 'iC i'r cc?;.; iv �t':;�€.�ri.,g—I b:'r�£G'#y ',.- -i.`fx�,+ra a'a4 cs h`.�i' 'kiixi,��fIWFOX`e{: i;t.. -- F, ,3 Yt '`'�Y a' ,i YR, "'$ 'fixr k.' 1 4 Ai eg t 4,qf `Ii yr :, IX. to f 1 .s x 1 p �'a�Via'"' " .•-, g 4 �,ti�tW it +1, rJesig`iisLl.Y.eLoads _a,F..sz&f .> f .4 std. ,k 4 t imt } � r $ s4. � fit i $ S Platform/Loft. NA .xisting Supported Floor Live Load Reduction 0 Yes 0 No ether -Wffiikd ififi4 r' Y tfAWX kt ASartRMNSg ;t tlt.g4 v€aP a VMdfatnigXaaMAt,i ?k b' 'iind•Speed . . 115(ultimate) 'nportance Factor 1 Exposure C _Fcceleratiori Coefficients(Ss,S1) .2.568,.979 Importance Factor 1 -"eismic.Occupancy Category II eismic Site Class D _eismic Design Category(*) E Lateral Resistance System NA • Provide to Architect immediately for their use in determining interior bracing requirements j atIrda it g}Cl tisaittla foofai o+f"s.1.oailt a iliilital trid1l -, NAfa �t ie t P Ground'Snow Load . '0 - ciat•Roof.Snow Load 0 ain on:Snow.Load 0 inin uirrperBuilding Official '20 Final Design Roof Load 20 u�nd tli teittekta - TOR ; zW . _ � i g TiNTWA OW4l P . EAMOM ' ra to 'ifindetibn Type NA - nearing Capacity NA Frost Depth NA ether NA o ' Tenant Fit-Out Design Criteria Project No 2016-1172 Date 5-Jan-17 • Protect: BBW-Santa Anita Prepared 01 JCP 0 Thorson•Baker+Associates Project Site: Arcadia,CA Prncipai. DLN •s;.i :r.. ,` .t ':.p.,,, s c :jk�k.S ri''''r ix�'b` 3+:;("7 z ."'71'ir'Ls 33'S7�+ ;" C;}F 3'.Yttm''ih,.tai .,�>.., 5t,ar GH f Zy Y- x{`•'t,Si `� .M ..rTel. Jk:if F •`S f ?^�c 9HR21S i F V.1$PEa� 4 C �(:�yLI �TS � 1,,5 pp .�t� � � �. ,�' �.� x �� �< � , �-1 ���, � g,�-x .L � F H. I! ,�< 2S.tti,.M1•t' �'a•^+�3ry F h wt i�aih r�u l Y S'� x h .�Pa'C1�'?+�t�'�.�y t'�s.J `§i ii,�.Cv��''�,t�k xt�'"�a����.�L v. ''__efios i toxon 8rdworaG i e ta'i�c< Y,r,k 'cic..4's fait x" ota rka.4'.d ;7..hi .wi _r{ raalmo'£'i,3.Rk::;ivonawa.'ke£.:u Full General Notes: ❑ SheetSpec General Notes: 0 • 3 3R^it „ fi?`i `p:.FTYyy'Ci�. r S�4 �d'f ''r,�, }¢�- 6 i ,i �f• `, tl'.s� y.y p:frt y, 1 , H �;4�r 5 ties 1��CI�fd�(fr��"� .��g� �,.� i� � �:t .r���:.-.,�ss�..� :y a3�� :rw�<.r•u �:��y��'�t�,s. � �%� �.M ��ik�. .���. �:,���:��. Tenant Fit-Out .p. 2/1/2010 • Glite`okfls0 ri �#1 01.010 M"1f <l1` ,,AMi �i^ k lMORMITO MANWE 4Witai ' n. >nien 13i'oJ .oli'`�aUM-ScX#fear�.,� ,'�`�M.IMPVAIEMIRAMMIVIM"�` `'�rg�,�„ %.- .:iWWWrM�-�OM Tenant Fit-Out - ❑ 2/112010 ;Preliminary - • ❑ 4/7/2011 - General Coordination ❑ 2/1/2010 General Notes ❑ 2/1/2010 ,FN D-Spread footings ❑ 2/1/2010 • • 'l ckrtlfh" fiIia bietdW ifla l tdfksltd'OMItlot uxafks iselst(edm gniaf ai!)O1adyfn iVand S PsiniMii<l spree $., r'` c A#fi ah"tatINAKEIVO co fiata•li i j•jo_1.: d fi; �. 11 t. - -.F r. . :+°fir .,., dam` 1Kesi,,rQga ipngak.� ,f Y.�t � A ".{ i• • 7'^'1ie" 404., �Y'.`" .!F l'9,`.0.r 0.1004?'.F-.+^'+444.-�fL1'"s'?�A?w'`T'z�Yo'.;?tMM.'Y2'RI#ItiffaNg �J, ' USES Design Maps Summary Report User-Specified Input Building Code Reference Document ASCE 7-10 Standard (which utilizes USGS hazard data available in 2008) ' Site Coordinates 34.14002°N, 118.03529°W Site Soil Classification Site Class D -"Stiff Soil" _ Risk Category I/II/tIII - %i, kr cIt +fix,; ` - .1.1."7.7-,. -r,rL(t i... .tr T i aS7G, 7 p a - .,�c ff,,,:r �I sal,' �fr r, r, "• 1 � < r „�1�SS �'i t atT t ;z '",- , .* . f .,,. �ee�" Sx-, r3; �, 4 ,-, '9, - .PAt.,.' p` ",:-.4;;..;,:".c, ,� 7•s?1 d , S� -���'s�{�'sd �,,,`..y'r'r�� c� + c p �`t, , y@;;zhl ai � '�� � i#� 7 � �1�� p%t����� ti�,'r ���l��r,{ � tR c!'��`�j },�•% v a¢ - � � > r � n 1'FS' ��.Q i��,� <{ ifi '(r C' 9 ,4-1, 1 `, '.4,i i '9 Y 7 L+�`w. fr ;'7,41.4. 'h s,,� ZT �( r��}` f�l� 1 1 l�/t��� .4 4341,1' 77R '��i �'S. �(y�i' �''�`��. i� � .� 3 � f"�� % "� yiy333�RYt f : h Xf0.,7 ,341 3 ":-:7-' °^ 4 ,y47..1471, r ,„go vt 14.17e.:.V r t' .� YDS. 'I, yk°Sc" S 1+ 1 ..F�p ,f z,o-^• �. 1� �14A 1�r "S K N py''' U f' Le' , {' i f ar , 'p i. 'd( Ob 'urt.c c r j. 4S^ i ' § o:.AAI . 1�`d"P.1,- rub i y`'a,. „ 1"T. '.a.-' ¢ I`' a. s 4 - , cs.l� If- is 4ks _ t- yilbi t. r 0 f >`i um,' 3'$ hCG 1 I'AU-itif atlr Ig; la e ! t e 'u} 1` .1Z-4.-4-1i:ik � nc ¢ _ x tf. t"! ller a 'cc l . C Y, ;VW-0410 `ST , 1, Ii � 4. Its* 1; +�. ..Y'w,i,�d+e,x R,s• ', ---v.0 "'� 1sy;11,: r+ 'S J _ F�,�,,./_ ,,,`,,,„, .[,.',;},.8 t ,-..,:.-,714,� e- 64 7,p � ,4t �7 ir. �Y''.0II,S�,!,.-E,-`... r 'h1, nf'f!E` �`^s ?4, 'i, •'+"14,14 lfYc�'-H. it"y- c Gil,[�',�i t �r �' ��' t9 'Iy, `•�'�'�t��1 t41+r3 EndQ,ra ` Jfi:- 4 d"r'-+ f�.z�ii , _7$ Ivst ; ` `ct 1y j . 0y `r-• Lr S K' d�-,y .1-, -,+ .ro t . %-w,p�a 4 ' 1'4 fo--g."� 2.? Ij{ul'<ay r Y�.rt,�{•,'�wr"0:21 Le k. r j '• a �r •,li I. I a.;y toe '.n„`"F'�j 0,...,,,F,/,:,,,,,,,„.. `'" t �c" i4 `�,5Li2.'1.�.fr ,,..,-,1,,,, C . .�'! t ',. LC'�tCt`t hr�. �,��7� r�i .�It ¢ .�4`c:cY;S�t'S't`notty,jJ t�`; t.�= r +�`� k'� :xu �� t � �r r. w '�+- �� 1 i s ��'�p n" tit, w i ew, l`�� -L+s,,�yrw q-, f ,t < s" s1 �r -1.$0,-...s..,,-0,---,:{� .-xi:Lr E ki- • #^Z� I f' i b.Y�L!w,-,,�`z t� }4`:+r-�."(4`. �r ,'S .p 3, os Inc `. `u_g1 +��`I!} [�,j�tfG Y-. d"t`i`' f`ktg Al c{4S ''.1§�' y' h. -c i .;e .. 0A 1.4`}4'1e I.:,,-r L ,It r: „. :. i�14,-, st - 1�i!` , .:',&,4!•� , ,t•.f fs,An �;-(L ' ,t}}+ Lp){1 ''j r�4 t lir 1�� at i ,(may yy. 3. - -i 4' �AS .k 14f 1.` .1 ?, � i` ii. �lm '�Oso fi ' ?44'.-4.0,--4t..:1,-� + P y; l�.xe,�' -'20,', tt l a 4 :.:�t4 `�Q`� -4 1 5P trF F t R s h- � f,r�,al 'i' t�, e q-(i i,c �wt v'f'J,.I-.:.. 5?� f�.l�ct d t 2�'W7r?.,L` .c.. . Lays z . "1 "''4c} ut 'r.'.,Aft '*„.. ',�.", .;�'kw.,'"N d( to t a�,e�.i J✓ t% i) s ryt-tstn 0)11.91"�{. },{ k 1c tc a:'h .:1:&-*„...'' x t ;.2. C.1 ! _ it,. - ieR 5.,..: 4t i'1.,,� zz.€.. .,j .._ ,. fc cuf.L l .g sLt ,-J_;i6- .�_,Ve..? :uM.� `Uu� ,. '!.✓.rr.-.. USGS-Provided Output SS = 2.568 g SMS = 2.568 g SDS = 1.712 g Si = 0.979 g SM, = 1.468 g SD, = 0.979 g -For information on how the SS and S1 values above have been calculated from probabilistic (risk-targeted) and deterministic ground motions in the direction of maximum horizontal response, please return to the application and select the"2009 NEHRP" building code reference document. MCER Response Spectrum Design Response Spectrum 2.86 1.99 2.50 1.80 2.35 1.62 2.08 1.44 1.82 1.26 1.56 T 1.08 M 1.30 Mcri 0.90 i 1.04 0.72 0.78 0.54 0.52 0.36 0.26 0.19 0.00 I I I I 1 I I I I I 0.00 0.00 0.20 0.40 0.60 0.80 1.00 1.20 1.40 1.60 1.90 2.00 0.00 0.20 0.40 0.60 0.80 1.00 1.20 1.40 1.60 1.90 2.00 Period,T(sec) Period, T(sec) For PGA,„ T„ CRSA and CR1 values, please view the detailed report. , Although this information is a product of the U.S.Geological Survey,we provide no warranty,expressed or implied,as to the accuracy of the data contained therein.This tool is not a substitute for technical subject-matter knowledge. 'ttp://earthquake.usgs.gov/designmaps/us/si3mmary.php?template=minimal&latitude=34.140018332525614&longitude=-118.03529005331288&sitecless=3&rislc.. 1/1 Title: Job# Dsgnr: Date: 5:10PM, 7 FEB 17 Description : -1 i Scope. S i Rev: 580000 User:KW-0602333,Ver 5.8.0,1-Dec-2003 Page 1 •1 i (c)1983-2003 e Multi-Span Steel Beam 2016-1172e ENERCALC EngineeringSof- - ... av:Calculations Description Multi Span for Front Beam General Information i .. _.,. .s. wr-.,y a., a:- V..:: .. .a............. . .a.. r...'.a... a,:....":. ..-..::. _.•-r, - .,sem- _! Fy-Yield Stress 46.00 ksi Load Duration Factor 1.00 All Spans Considered as Individual Beams Span Information �::,a.,tzrr<rtes+:e.s^.eGseaxrearw,.a:=�:w.«.u.a�.y:.�.s..r..m�cr.y.e.-..,�..s, uvnr.rr+.awr.+.-sr•,+-.:.+.-., +-.w..-.,.».r,rxatt,+rr.,•...,riM.:x-:w>r>wxFt_.,,F.,>..,aeaa-.�rnti ! '.'" f.+arz.raK,r . Description Storage Span Main Span Right Span Span ft 7.00 33.00 4.00 -- Steel Section HSS1OX6X1/4 HSS14X6X5/16 HSS10X6X1/4 End Fixity Pin-Pin Pin-Pin Pin-Pin Unbraced Length ft 0.00 0.00 0.00 Loads Live.Load Used This Span?_ Yes Yes Yes Dead Load k/ft 0.100 0.100 0.100 Live Load k/ft - Results ' r Mmax @ Cntr k-ft 0.61 13.61 0.20 _ @ X= ft 3.50 16.50 2.00 Max @ Left End k-ft 0.00 0.00 0.00 - - Max @ Right End k-ft 0.00 0.00 0.00 fb:Actual psi 379.3 4,219.4 123.8 Fb:Allowable psi 27,600.0 27,600.0 27,600.0 Bending OK Bending OK Bending OK . fv:Actual psi 0.0 0.0 0.0 Fv:Allowable :psi 18,400.0 18,400.0 18,400.0 Reactions&Deflections Shear @ Left k 0.35 1.65 0.20 Shear @ Right k 0.35 1.65 0.20 Reactions... DL @.Left k 0.35 1.65 0.20 _ LL @ Left k 0.00 0.00 0.00 Total @ Left k 0.35 1.65 0.20 DL @ Right k 0.35 1.65 0.20 LL @ Right k 0.00 0.00 0.00 Total @ Right k 0.35 1.65 0.20 Max. Deflection in -0.002 -0.340 -0.000 @ X= ft 3.50 16.50 2.00 Span/Deflection Ratio 43,697.6 1,166.4 234191.7 Query Values i -- rr R .„„ -,-,,t;,.,„„.„_„....__„..-. z,r„ws.=,,,x,w4,ns?,t,,,,,,,,,,c .nr. .-,,,,,a,.•.:l=,,,,, .,.F .v.,Er,-7-^_,..fc-:M- :rS.K,ry;Se•;u,,ht!.,e-'•-TA:: a-1,,,, .i,v:,�iF sr,:ci.. Location ft 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 Shear k 0.35 1.65 0.20 0.00 0.00 0.00 0.00 0.00 Moment k-ft 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 Max. Deflection in 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 . ,_ Box Beam Design Sr Job#: 2016-1172 Date: 2/7/2017 Project: BBW-Santa Anita Prepared By: JCP Project Site: Arcadia, CA Pricipal: DLN Description: Storefront Header-Rear Span (Worst Case) Span(L)= 33 ft F = 50 ksi Laterally Braced @: 4 ft Gravity Loading Calcs: Gravity Line Load = 50 plf Lateral Loading Calcs: Trib Height Below= 4 ft Trib Height Above= 2 ft Wind Load(Ww)= 5 psf Wind Line Load= 30 plf Seismic(SDS). 1.712ap= 1 Ip= 1 Rp= 2.5 Line Load =[(Wp*z*ap*SDS*0.4)/(Rp/Ip)]*[1+2*(z/h)]= 68 plf IIIIME11111 *Seismic Controls r;RI fii�WAIP: Gravity Lateral Load(w)= 50 plf Load (w)= 68 plf M= (w*L2)/8 6.81 ft*k 0.14 ft* A= L/ 400 0.990 in 0.990 in S REQ= M/(0.6*Fy) 2.72 in3 0.05 in3 I REQ= (5*w*L4) 46.47 in4 0.01 in4 (384*E*A) Try: (2) 14"CSJ Studs x 14 GA wl(2) 3 5/8"TSB Tracks x 18 GA Sx= 6.836 in3 Sy= 0.968 in3 Ix= 56.686 in4 ly= 1.616 in4 BOX BEAM IS SATISFACTORY \\Tbs-projects03\2016\2016-1172\Engineering\Engineering-Structural\2016-1172 Rear Span Box Beam Calc.xls 2/7/2017 5:08 PM Project No: Z O 16-1/7 Z Sheet No: A-fru'"- [3 OW- S�4N7I ATETI 2/$ui/ Project: n_ _ Date: Thorson•Baker+Associates t I Cry Prepared By: L� Project Site: �� c CONSULTING ENGINEERS Narrs ( ) r.14 = 0 L = 3(--1' 1- x57 Psr- ;('a1 es,F L_ 75 �= c(`' w,,_o t,i c P SPS cRt -As LA)/ 70P 1 c 6,4os pL ygy pcF 1� = 3 op pl 1aA9S = zc 3' �7 `p , n,e, • J -- �g. z t.Fr OGI � _ L �, �" of R -a V ?1 ,76 (2,07 t` 7, V> 1 �fl C N ! 01„ 3er ( 2. S frrig'ri' , 1:23 reirec.1:4-6. ,0 ' Title: Job# Dsgnr: Date: 11:55AM, 8 FEB 17 Description: Scope: Rev: 580000 User.KW-0602333 Ver 5.8.0,1-Dec-2003 Page �1 �(c)1983-2003ENE�2CALC EngineeringSofhvare Single Span Beam Analysis 2016-1172ecw:RTU c®s^}cssu: m•mmz° .asxarmxaassiwfsr�aa.-..r.- :� - ss.snsac:n.-u.. •;.. , - Description (E) Condition General Information '? Center Span 30,00 ft Moment of Inertia 1,000.000 in4 Left Cantilever ft Elastic.Modulus 29,000 ksi Right Cantilever ft Beam End Fixity Pin-Pin Uniform Loads .. ...; a.'�vs,fs's."•.xrr•.. - @X�• w • o. -"..e.� ..-....-..'s V�S- On Center Span... On Left Cantilever... On Right Cantilever... #1 0.784 k/ft #1 k/ft #1 k/ft • • Query Values a Center Location 0.000 ft Left Cant 0.000 ft Right Cant 0.000 ft Moment 0.00 k-ft 0.00 k-ft 0.00 k-ft Shear 11.76 k 0.00 k 0.00 k Deflection 0.00000 in 0.00000 in 0.00000 in f iySummary -- Moments... Shears... Reactions... Max+@ Center 88.20 kft at 15:03 ft @ Left 11.76 k @ Left 11.76 k , Max-@ Center 0.00 k-ft at 30.00 ft @ Right 11.76 k @ Right 11.76 k Maximum 99 R3_C3 @ Left Cant 0.00 k-ft @ Right Cant 0.00 k-ft Deflections... @ Center -0.493 in at 15.03 ft Maximum = XB1 MI ' @ Left Cant. 0.000 in at 0.00 ft @ Right Cant 0.000 in at 0.00 ft Title: Job# Dsgnr: Date: 11:55AM, 8 FEB 17 Description : 44LL3 Scope: —: Rev: 580000 User:KW-0602333,Ver 5.8.0,1-Dec-2003 Page 1 $ (c)1983-2003 ENERCALC Engineering Software Single Span Beam Analysis ,. 2016-11 2.ecvrRTU. Description (N)Condition General Information Li Center Span 30.00 ft Moment of Inertia 1,000.000 in4 Left Cantilever ft, Elastic Modulus 29,000 ksi Right Cantilever ft Beam End Fixity Pin-Pin Uniform Loads . _ .... ,_... ,,., . .. a.� , .:. On Center Span... On Left Cantilever... On Right Cantilever... #1 0.784 k/ft #1 k/ft #1 k/ft Point Loads • Magnitude 0.200 k 0.200 k k k k Location 3.000 ft 8.000 ft ft ft ft Query Values - .-,,,,..„-.„,..--.,,,,,..,,.......,....-,..„-,...7,—...,,,,,,- #.7-A`i;3".... LVieai.&b9 ,177 FM FrAgANt, ..54.VI+*t.33.$ .-^••--.�.0Me 47.0 _ ._ Center Location 0.000 ft Left Cant 0.000 ft Right Cant 0.000 ft Moment 0.00 k-ft 0.00 k-ft 0.00 k-ft Shear 12.09 k 0.00 k 0.00 k Deflection 0.00000 in 0.00000 in 0.00000 in ^:rraa,,,,,,rtr:. >icxar.:F<r a.- ..9 Summary Moments... Shears... Reactions... Max+@ Center 89.30 k-ft at 14.91 ft @ Left 12.09 k @ Left 12.09 k Max-@ Center 0.00 k-ft at 30.00 ft @ Right 11.83 k @ Right 11.83 k Maximum c j @ Left Cant 0.00 k-ft @ Right Cant 0.00 k-ft Deflections... @ Center -0.500 in at 14.97 ft Maximum = 89.3: eft @ Left Cant. 0.000 in at 0.00 ft @ Right Cant 0.000 in at 0.00 ft ' Adhesive Anchoring Systems .-!'jE]'1,,+',..- - j "lit, M i 3.2.7 HIT-HY 70 Hybrid for Masonry Construction Table 13-HIT-Hy 70 allowable adhesive bond seismic loads for threaded rods and A-14-1,L- i 1 reinforcing bars in unreinforced brick masonry1'2,3 , Configuration A—Shear anchor or rebar dowel , z t3 Nominal anchor ,.. diameter Bar Embedment Minimum wall thickness Tension Shear4 ` . 4 in. size in. (mm) in. (mm) lb (kN) lb (kN) Le Y ' 1 1/2 4 500 (2.2 ., i 5/8 5 8 (203) 13 (330) - - 750 3.3� r ' ' 3/4 6 - - 1,000 (4.5) Configuration B—22 1/2°combination anchor 1. f Nominal anchor diameter Embedment Minimum wall thickness Tension Shear' S*O'''*,i. 4 in. in. in. (mm) lb Within 1 inch of the 1 `, " 3/4 13 (330) 1,200 (5.3) 1,000 (4.5) opposite wall surface 1 Allowable load values are applicable only to anchors where in-place shear tests indicate minimum mortar strength of 50 psi. _ a; 2 Allowable loads are computed in accordance with ICC-ES AC60(2010)and IBCi`• •F+* , 3 No increase for short-term loading is permitted,such as loading induced by wind or earthquake. 7 y'.,,4aj 4 Anchors must be tested in accordance with the requirements of IEBC and UCBC. ,r Figure 9— Hilti HIT-HY 70 shear anchor Figure 10—Hilti HIT-HY 70 with 22-1/2° ,,,,%:,:.,44-7,, I or dowel in configuration A combination anchor in configuration B :,' Varies 8,, '';',,:;:,17.-°.,,,t,,,j,:vi..1:4:".;.. 24I r t -494 �s Shear anchor n ' 1� p :. lr r 4} 1/2-,5/8-or 3/4-in. it �` _, 3/4-in.diameter :3,'F l, diameter ASTM A307 ASTM A307 I ; rN / t € .Faru /threaded rodn€a' Y f threaded rod u� 3�'�rr�" 'ri Ir�� 111111114.�IlnilllllllllllllAlllllllllllllllmatlllllrav __ +ra. a� _ 3 tr, Q Sheardowelno.4. — j� \\\allnrll .�- 1 i r- �y j '41. ,? no.5 or no.6 rebar ,3 411'?ir ,\\\\\ -''• ,tr-:: t s t!i ,t-s.3r "4 221/2° i.+4•U\� ^;3j4�voon. , -. Screen tube In ` i tit ! a,- 14-A. `` i Screen tube In 1-in.diameter hole _' ,.1-in:diameter hole ,i, _Table 14-HIT-HY 70 allowable adhes've.bond loads for threaded rods in hollow core concrete panels1.4.5,6Nominal anchor Effective Minimum diameter embedment concrete thickness Tension Shear , in. in. (mm)2 in. (mm)3 lb (kN) lb (kN) 9,i 9 3 2 (50.8) 1-3/8 (34.9) 0 p;' (2.0) 560 (2.5) a 1 All values are for anchor installed in hollow core concrete with minimum compressive strength of 7,000 psi.Due to variations in materials and dimensional I configurations,on-site testing is required to deterinine the actual performance of the anchor.Allowable loads are calculated using a safety factor of 5. . A 2 Tabulated embedment depth is limited bythe length of the plastic HIT-SC 16x50 mm screens.See figure 11. ,40. P 9 P r. 3 The required concrete thickness is the thickness for which values are available and installation is recommended.Anchors shall be installed along the centerline of the Al . hollow core or along the line of minimum thickness.Verify these requirements with the hollow core plank supplier before installation.The required thickness is measured :Alt ?3 from the inner to the outer side of the hollow core panel.In case of deviation from the outlined requirements,field testing is required.See figure 11_ *:, 4 Tabulated allowable loads must be the lesser of the adjusted concrete or bond values tabulated and the steel values in table 4. ,1. 5 Tabulated allowable bond loads shall be adjusted for increased base material temperatures in accordance with figure 12. l , 6 The required adhesive gel and cure times shall be identical to the values adopted for masonry. - Figure 11 -Hilti HIT-HY 70 adhesive installed in hollow core concrete " 3 i> - -. z -r i' . Representation of .y s•• •.:i the tested conditions 'Y s :., for which allowable 4 : ' °c ' adhesive band c'p,,..,: loads are applicable. l Refer to footnote 3 e+!( ;i of corresponding : r - 'r load table above for i • ' I , 'r .,:::.n.,:::: F,1;a mom information on x,.� c h a requirements and 6 'I restrictions on the ''. p 9 `1•t' admissible anchor installation. 1 a,w1.3/8;_s. V''' ,, Admissibleanchbrlocaticn' 1 ;i - f-� 3/8-in.diameter threaded rod V4+ in combination with HIT-SC 16 x 50 mm ,,0 170 Hilti,Inc.(US)1-800-879.8000 I www.us.hilti.com I en esparto)1-800.879-5000 I Hilti(Canada)Corp.1-800-363-4458 I www.hilti.ca I Anchor Fastening Technical Guide 2014 `4 ECLIPSE ECLIPSE - ENGINEERING . COM ENGINEERING Structural Calculations Steel Storage Racks By Pipp Mobile Storage Systems, Inc. PIPP Po #24465 SO #59880 h Er, 0 n 0.017i �9PpFESSlUj�44 Bath & Body Works #780 i�� Nicholas StiverBumam2, C . 8 g =3. Santa Anita Fashion Park -, CMI En -eer 400 S. Baldwin Ave - Space #Al2 � -of _�A��F • Arcadia, California 91007 Prepared for: Pipp Mobile Storage Systems, Inc. 2966 Wilson Drive NW Walker, MI 49544 Please note: The calculations contained within justify the seismic resistance of the shelving racks, the fixed and mobile base supports, and the connection to the existing partition wallsfor both lateral and overturning forces as required by the 2016 California Building Code. These storage racks are not accessible to the 17 general public. 540 MISSOULA COLUMBIA FALLS SPOKANE BEND 113 West Main,Suite B,Missoula,MT 59302 729 Nucleus Ave,State D,Columbia Fads,MT 69912 421 West Riverside Ave.,Suite 421 Spokane,WA 99201 376 SW Bluff Drive,Suite 8,Bend,OR 97702 Phone:(406)721-5733•Fax(406)721-4998 Phone:(406)892.2301•Fan:406892-2368 Phone:(509)921.7731•Fax(509)921-5704 Phone:(541)389-9659•Far(541)312.8708 .. s EC LI PS E BATH&BODY WORKS#780 2/9/2017 • ENGINEERING ARCADIA,CA Rolf Armstrong, PE Pipp Mobile STEEL STORAGE RACK DESIGN 2016 CBC & ASCE 7-10 - 13.3.1 & 15.5.3.4 Design Vertical Steel Posts at Each Corner - Shelving Dimensions: Are Shelving Units set as Single Depth(1)or Back to Back(2)? Nu:= 1 Total Height of Shelving Unit- ht:= 10.00-ft plf:= Ib•ft 1 Width of Shelving Unit- w:= 4.00.ft psf:= lb.ft—2 Depth of Shelving Unit- d:= Nu•(1.5•ft) = 1.5ft pcf:= lb.ft—3 Number of Shelves- N:= 5 kips:= 1000.lb Vertical Shelf Spacing- S:= 30.00.in ksi:= kips.in 2 Shelving Loads - Maximum Live Load on each shelf is 100 lbs: Weight Load in Design Live Dead Load per shelf- psf- Load on Shelf- on Shelf- Wtj:= Nu•(100.lb) = 100lb LLj:= WtI = 16.6667.psf w•d LL:= LLi= 16.6667 psf DL:= 2.50 psf Section Properties of Double Rivet 14 Gauge Steel 'L' Post : Modulus of Elasticity of Steel- E:= 29000.ksi Steel Yield Stress- Fy:= 33.ksi Physical Dimensions of L Post: Density of Steel- psteel:= 490.pcf L Post Width-out-to-out- b1:= 1.500.in L Post Depth-out-to-out- d1:= 1.500.in Radius at Corners- R0:= 0.188.in Post Thickness(14 Gauge)- t:= 0.0750.in L Post Width-End-to-IF- L Post Depth-End-to-IF- bic:= b1— t= 1.425•in dip:= d1— t= 1.425•in Radius of Gyration in x and y- rX:= 0.5390•in ry:= 0.5390•in Section Modulus in x and y- 5x:= 0.0396.in3 Sy:= 0.0396.in3 Moment of Inertia inxandy- lx:= 0.0406.in4 ly:= 0.0406.in4 Full&Reduced Cross Sectional Area's- Apf:= 0.225.in2 Apr:= 0.138.in2 Length of Unbraced Post- L,<:= S= 30.00•in Ly.= S= 30.00•in Lt:= S= 30.00•in Effective Length Factor- K,:= 1.7Ky:= 1.7 Kt:= 1.7 Weight of Post- Vertical DL on Post- Vertical LL on Post- W := steel A lit= 7.661b P :_ DL w d•N + W — 26.411b P1:— LL•w•d•N — 125lb p P Apr d — 4N p— � — 4. u Total Vertical Load on Post- Pp:= Pd + Pi= 151.411b 1 ECLI PS E BATH 9 BODY WORKS#780 2/9/2017 ENGINEERING ARCADIA,CA Rolf Armstrong,PE • Floor Load Calculations : Weight of Mobile Carriage: W,:= 0.Ib Total Load on Each Unit: W:= N •4•Pp+ Wo+ W11= 705.63 lb Area of Each Shelf Unit: A„:= w•(d+ 12.in) = 10 ft2 Floor Load under Shelf: PSF:= — =W 71.psf At, NOTE:SHELVING LIVE LOAD IS CONSISTENT WITH 100 psf REQ'D FOR RETAIL FLOOR LOADING Find the Seismic Load using Full Design Live Load - ASCE-7 Seismic Design Procedure: Building's Risk Category- BRC:= 2 Importance Factor- lE:= 1.0 Determine Ss and S1 from maps- SS: 2622 S1:= 0.992 Determine the Site Class- SSC:= "D" Determine Fa and F„ - Fa= 1.000 F,= 1.500 Determine SDs and Spl_ SDS:= 3•(Fa•Ss� 1348 SD1:= 3•(F;Si)= 0.992 J _ Seismic Deisgn Category- JSDC= "E" Structural System-Section ASCE-7 Sections 13.3.1 9 15.5.3.4.: 4.Steel Storage Racks R:= 4.0 Ito:= 2 Cd:= 3.5 Rp:= R ap:= 2.5 Ip:= 1.0 Total Vertical DL WP Total Vertical LL Load on Shelf- Wd DL•w•d+ N„.4.N = 21 Ib Load on Shelf- W1:= LL.w.d= 100lb Seismic Analysis Procedure per ASCE-7 Sections 13.3.1915.5.3.4: Average Roof Height- hr:= 36.0.ft Height of Rack Attachment- z:= 0.ft Grou For Ground floor) 0.4 ap•SDs Seismic Base Shear Factor- Vt:= Rp •'1+ 2. z = 0.437 Ip Shear Factor Boundaries- Vtmin 0.3•SEG.Ip= 0.524 VtmaX:= 1.6•SOS.IP= 2.797 Seismic Coefficient- 114:= min(max(Vtmin,Vt),Vtmax) = 0.524. Overstrength Factor- It:= 2.0 NOTE: By ASCE 7-10 Section 13.3.1,S2 does not apply for vertically cantilevered architectural systems. 2 ECLI PS E BATH 8 BODY WORKS#780 21912017 • ENGINEERING ARCADIA,CA Rolf Armstrong,PE Seismic Loads Continued : ASD t_RFD For ASD,Shear maybe reduced- Vp:= 0.7•Vt= 0.367 VI*:= Vt= 0.524 Seismic DL Base Shear- Vtd:= Vp•Wd•N = 38.771b Vtdo:= Vp�•Wd•N = 55.39lb DL Force per Shelf: Fd:= Vp•Wd = 7.751b Fdo:= Vpd,•Wd= 11.081b Seismic LL Base Shear- Vd:= V •Wi•N = 183.54 Ib Vti�:= Vpd,•Wi•N = 262.2lb LL Force per Shelf: F1:= Vp•Wi= 36.711b F1 := Vpd,•Wi= 52.441b 0.67 LL Force per Shelf: F1.67:= 0.67•Vp•Wi= 24.59 lb F1674):= 0.67•Vp4,•Wi= 35.13 lb Force Distribution per ASCE-7 Section 15.5.3.3: Operating Weight is one of Two Loading Conditions-Condition#1:Each Shelf Loaded to 67%of Live Weight: Cumulative Heights of Shelves- H1:= 1.0•S+ 2.0•S+ 3.0•S+ 4.0•S+ 5.0•S H2:= 0 H:= H1+ H2= 37.50ft Total Moment at Shelf Base- Mt:= H•Wd+ H.0.67•Wi= 3304.69 ft-lb Total Base Shear- -V1:= Vtd+ 0.67•V1= 161.74 IP" Vld,:= Vtd,+ 0.67•Vt1 = 231.06 lb Vertical Distribution Factors for Each Shelf- Wd•1.0.S+ 0.67.1.0•S Wd•2.0•S+ WI.0.67.2.0•S C1:= = 0.067 C2:= = 0.133 Mt Mt F1:= Ci-(Vi) = 10.781b F1.0:= C1•(V1o) = 15.401b F2:= C24V1) = 21.571b Fat,:= C2-(V4) = 30.81 lb Wd•3.0•S+ Wi•0.67.3.0•S Wd•4.0•S+ Wi•0.67.4.0•S C3:= = 0.200 C4:= = 0.267 Mt Mt F3:= C3•(V1) = 32.351b F34,:= C3•(V1o) = 46.211b F4:= C4.(Vi.) = 43.13lb F4d,:= C4.(V1o) = 61.621b Wd•5.0•S+ Wi 0.67.5.0•S C5:= M = 0.333 t F5:= C5•(Vi) = 53.91 lb F5,0:= C5•(V1d,) = 77.02lb C1+ 02+ C3+ C4+ C5= 1 Coefficients Should total 1.0 3 ECLI PS E BATH&BODY WORKS#780 2/9/2017 ENGINEERING ARCADIA,CA Rolf Armstrong, PE - Force Distribution Continued : Condition#2:Top Shelf Only Loaded to 100%of Live Weight Total Moment at Base of Shelf- Mta:= H Wd + (N)•S.Wi= 2042ft.lb Total Base Shear- V2:= Vtd+ F1= 751b V20:= Vtdd,+ Fid= 1081b Wd•1.0•S+ 0.Wi•1.0•S Wd•2.0•S+ 0•W1.2.0.S Cla:= = 0.026 C2a:= = 0.052 Mta Mta Fla:= Cia•(V2) = 2lb Flab:= Cla(V20) = 2.81b F2a:= C2a•(V2) = 3.9lb F2a4,:= C2a(V20) = 5.61b Cia+ C2a+ C3a+ C4a+ C5a= 1 Coefficients Should total 1.0 • Condition#1 Controls for Total Base Shear By Inspection,Force Distribution for intermediate shelves without LL are negligible. Moment calculation for each column is based on total seismic base shear. Column at center of rack is the worst case for this shelving rack system. Column Design in 1 SBending Stress Ms Short Direction: Ms'= max(Vl, v2) = on Column- fbx:= = N 15.32 ksi u4 2S x Allowable Ratio of Allowable/ tbx i MUST BE LESS Bending Stress- Fb:= 0.6 Fy= 19.8 ksi 07 Ultimate Stress- Fb '7THAN 1.0 Bending at the Base of Each Column is Adequate 4 ECLI PS E BATH>1 BODY WORKS#780 21912017 • ENGINEERING ARCADIA,CA Rolf Armstrong,PE Deflection of Shelving Bays-worst case is at the bottom bay-the following is the list of shears used in deflection equations. VA1:= V1— F1= 151 lb VA2:= Vol— F2 = 129 lb VA3:= VA2— F3= 97 lb Vola:= V2— Fla= 741b VA2a Vola— F2a= 701b Vo3a Vola— F3a= 641b E 1 max(VA1,VAia)•S3 S 1 max(VA2,VA2a� S3 D13 := = 0.0721.in — - 415.96 02:= = 0.062•in Nu.4 12.E.l Ol Nu•4 12•E•l Da:= 0.05.ht= 6•in / t:= + 6,2+ 6,3 + 6,4+ 05= 0.207.in if(At< Aa,"Deflection is Adequate","No Good") = "Deflection is Adequate" Note:The deflection shall not exceed 5%H1,so shelving deflection is adequate. Moment at Rivet Connection: 2 Shearon dr:= 0.25 in Vr:= MS = 404.36 lb Ar:= dr = 0.0491.in2 each rivet- 1.5. .5 in 4 Steel Stress Vr Ultimate Stress on Rivet Omega Factor on Rivet- fv:= A = 8.24•ksi (SAE C1006 Steel)- Fur = 47.9ksi (ASD)- ft,:= 2.0 r Allowable Stress 0.4.Fur Ratio of Allowable 1 fv on Rivet- Fvr:_ = 9.58•ksi Ultimate Stress- — = 0.86 MUST BE LESS THAN 1.0 �r Fvr RIVET CONNECTION IS ADEQUATE FOR MOMENT CONNECTION FROM BEAM TO POST Seismic Uplift on Shelves : Seismic Vertical Vertical Dead Component: Ev:= 0.2•SDs (DL+ LL)•w•d= 40.201b Load ofShelf: D:= (DL+ LL)•w•d= 115.00 lb Note:since the shelf LL is used to generate the seismic uplift force,it may also be used to calculate the net uplift load. For an empty shelf,only the DL would be used,but the ratio of seismic uplift will be the same. Net Uplift Load on Shelf: Fu:= E„— 0.6.D Fu= —28.801b Note: This uplift load is for the full shelf. Each shelf will be connected at each corner. Number of Shelf 4 Uplift Force F : Fu— F 7.201b Connections: = _per Comer: u� N uc= — c NOTE:Since the uplift force is negative,a mechanical connection is not required. 5 .*,1% EC LI PS E BATH 9 BODY WORKS#780 2/9/2017 ENGINEERING ARCADIA,CA Rolf Armstrong, PE • Find Allowable Axial Load for Column : Allowable Buckling Stresses- Tr2•E gex:_ / \2 vex= 31.97.ksi II Kx'Lx Il rx ) Distance from Shear Center t•dict'bic2 to CL of Web via X-axis e�:= e0= 1.9043.in 4.1x Distance From CL Web to xo:= 0.649•in— 0.5•t x0= 0.6115•in Centroid- Distance From Shear Center xo:= xo+ eo xo= 2.5158•in to Centroid- Polar Radius of Gyration- ro:= Jrx2+ ry2 + xo2 r0= 2.6287.in Torsion Constant- J:= 3•(2.for + di.t3) J= 0.00063•in4 t•bi3•di2 (3.bi•t+ 2.40 6 Warping Constant- C := Cw= 0.0339.in 12 6.bi•t+ di•t ) Shear Modulus- G:= 11300.ksi 1 r Tr2•E.Cwl vt:= G•J+ vt= 11.4105.ksi Apr rot L (Kt•Lt)2 2 _ (3:= 1— p Ir x01 = 0.0841 ro 1 Fet:= 1R' (vex+ vt) —/(o-ex+ vt)2— 4•(3•vex'vt Fet= 8.5509•ksi Elastic Flexural Buckling Stress- Fe:= if(Fet< vex' Fet,vex) Fe= 8.5509•ksi Allowable Compressive Stress- Fo:= ifrFe > FY, F .r1— Fy. 1, Fe Fn= 8.5509•ksi L 2 4.Fe) Factor of Safety for Axial Comp.- no:= 1.92 6 k5. ECLI PS E BATH&BODY WORKS#780 2/9/2017 • ENGINEERING ARCADIA,CA Rolf Armstrong,PE Find Effective Area - Determine the Effective Width of Flange- Flat width of Flange- wf:= b1— 0.5•t Wf= 1.4625•in Flange Plate Buckling Coefficient- kf:= 0.43 w F Flange Slenderness Factor- a := 1052 f n of= 0.5372 t E 0.221 1 pf:= "1— Xf )• Xf pf= 1.0992 Effective Flange Width- be:= if(Xf> 0.673, pf•Wf,wf) be = 1.4625.in Determine Effective Width of Web: Flat width of Web- ww:= d1— t ww= 1.425.in Web Plate Buckling Coefficient- kw:= 0.43 w Web Slenderness Factor- Xw:= 1 w • ° aw= 0.5234 {� t E pw:= (1— 0.221 1 Pw= 1.1075 Xw ) �w Effective Web Width- he:= if(Xw> 0.673, pw•ww,ww) he = 1.425.in Effective Column Area- Ae:= t•(he+ be) Ae= 0.2166•in2 Nominal Column Capacity- P„:= Ae•F„ P„ = 18521b P • Allowable Column Capacity- Pa:= n Pa= 9641b �o Check Combined Stresses - �2•E Ix Pax Pm(= 4467.69 lb (Kr.LO2 Pcr Pcrx Per= 4467.69 lb (no•Pp) Magnification Factor- a:= 1— = 0.935 C,„:= 0.85 Pcr ) Combined Stress: Pp + Cm•fbx = 0.86 MUST BE LESS THAN 1.0 Pa . Fb•a' Final 14 GA. 'L' POSTS ARE ADEQUATE FOR REQD COMBINED AXIAL AND BENDING LOADS Design: NOTE: P is the total vertical load on post, not 67% live load, so the design is conservative 7 „'"4 EC LI PS E BATH Fi BODY WORKS#780 2/9/2017 ENGINEERING ARCADIA,CA Rolf Armstrong, PE - STEEL STORAGE RACK DESIGN - cont'd Find Overturning Forces : Total Height of Shelving Unit- ht= 10ft Width of Shelving Unit- w= 4ft Depth of Shelving Unit- d= 1.5ft WORST CASE Number of Shelves- N = 5 Vertical Shelf Spacing- S= 30.in Height to Top Shelf Height to Shelf (N + 1) Center of G- htop ht= 10 ft Center of G- ho:- 2 •S= 7.5 ft From Vertical Distribution of Seismic Force previously calculated-Controlling Load Cases: ASD Ma:= F1.1.0•S+ F2.2.0.S+ F3.3.0.S+ F4.4.0.S+ F5.5.0.S Moments- Mb:= 0 LRFD Mao:= Fw1.0.S+ F24,•2.0.S+ Fw3.0.S+ F44).4.0.S+ F54).5.0•S Moments- Mb4,:= 0 For Screws-ASD For Anchors-LRFD Weight of Rack and 67%of LL- W1:= N.(0.6 — 0.14.SDs)•(Wd+ 0.67.W1) = 156.55 lb W14,:= N.(0.9— 0.2.SDs)•(Wd + 0.67.WI) = 242.52 lb Overturning Rack and 67%of LL- M1:= Ma+ Mb= 1482.66 ft.Ib Ml4,:= Mao+ Mb4, = 2118.08 ft.lb Seismic Rack and 67% T1:= Olb T1�:= Olb of LL Tension&Shear- V1= 161.74 lb V14, = 231.06 lb Weight of Rack and 100%Top Shelf- W2:= (0.6— 0.14•SDs)•(Wd•N + w1) = 73.05lb W24):_ (0.9— 0.2•SDs)•(Wd•N+ W1)= 113.18 lb Overturning Rack and 100%Top Shelf- M2:= Vtd•ho+ Fr htop= 657.88 ft.lb M24):= Vtdo•he+ Fac.htop= 939.82 ft.lb Seismic Rack and 100% T2:= Olb T20:= Olb of LL Tension&Shear- V2= 75.481b V24, = 107.83 lb Force on Column Screws &Anchors: Tension Single - Tam,:= max(21, 22,0.1b)) •Ib)= 80.871b Tsai*,:= max(T14,T20,0.1b)= 0.00 V14, V2,4, Shear Single- Varna),:= max(Tl,T2,0•Ib) = 0.00 \i mam,:= max —2 , = 115.531b 2 8 11 EC LI PSE BATH G BODY WORKS#780 2/9/2017 ENGINEERING ARCADIA,CA Rolf Armstrong,PE STEEL BASE CLIP ANGLE DESIGN -A1018 PLATE STEEL Tension(Uplift)Force Yield Stress of at Corner. T:= 50 Ib Angle Steel: FyP:= 36.ksi Thickness of Angle: to:= 0.075.in 14 ga Foot Plate Width of Angle Leg: ba:= 1.25.in Length of Angle La:= 1.375•in Section: Distance out to L:= 0.75•in Section Modulus S ba tat = 0.0012 in3 Tension Force: of Angle Leg: e 6 Design Moment Bending Stress M on Angle: M:= T.L= 3.125ft.lb on Angle: fb:= S— = 32•ksi e Allowable Bending Ratio of fb b F := 0.90.F 32.4.ksi = 0.988 MUST BE LESS THAN 1.00 Stress: vP= Allowable Loads: Fb Ultimate Tensile F — 65 ksi Gross Area of q •— b t 0.0938 int Strength of Clip: uP the Clip: Age•— a a= Effective Net Area of the Clip: A„ Ago— ta•(0.375•in) = 0.0656•in2 Limiting Tensile Strength of Clip: Tem*,:= min (0.90.Fyp•Age),(0.75.Fee•Aec) = 3037.5 lb lif(Toma*•>Tsmaz,; "Checks'Okay"., "No Good") = "Checks Okay" 14 GA. ANGLE CLIP WILL DEFORM PRIOR TO ANCHOR PULLING OUT OF CONCRETE, BUT NOT WILL NOT TEAR COMPLETELY THROUGH, THEREFORE CLIPS ARE ADEQUATE. BEARING STRENGTH OF SCREW CONNECTIONS - AISI E.4.3.1 Omega for Bearing(ASD)- Sts:= 3.00 St := 2.35 Specified Tensile Stress of Clip 6 Post,Respectively- F„1:= 51ksi Fut:= 51ksi Diameter of Screw- dee:= 0.25in 14 GA Clip Thickness- t1:= 0.075in 14 GA Post Thickness- ts2:= 0.075in Nominal Bearing Strength- Single Screw-ASD rr 3 4.2 Fut• dss•ts2 (AISI GE4.3-3) Pns:= min 2.7•Fur dss•tsl = 22001b 2.7•Fut*dss•ts2 )J Allowable Bearing Strength- Pas:= Pns = 733.3 lb s_ts 9 • ,z3.5. EC LI PSE BATH G BODY WORKS#780 2/9/2017 ENGINEERING ARCADIA,CA Rolf Armstrong,PE SCREW CONNECTION CAPACITIES (1/4"(1) SCREW IN 14 GA STEEL): Note:Values obtained from'Scafco'tabels using an 0=3.00 Single Screw-ASD Allowable Tensions, Pullout- Tsst:= 227lb Allowable Tensions,Pullover- Tssv:= 6561b Allowable Shear- Vss:= 600lb The allowable shear values for(1)114"dia.screw exceeds the allowable bearing strength of Ref Attached'Scafco'Table the connection. Therefore,bearing strength governs for screw connection capacity. forV&T Values BOLT CONNECTION CAPACITIES (3/8" DIA. x 2" HILTI KB-TZ): Single Anchor-LRFD Ref Attached'HILTI' PROFIS calcs for V S T Allowable Tension Force- Tas:= 1051.1b Values Allowable Shear Force- Vas:= 1466.1b DETERMINE ALLOWABLE TENSION/SHEAR FORCES FOR CONNECTION: Single Screw-ASD Allowable Tension Force- Tasi:= min(Vss, Pas)= 600 lb Allowable Shear Force- Vasi Tssv= 656 lb USE: HILTI KB-TZ ANCHOR (or equivalent)-318"x 2" long anchor installed per the requirements of Hilti to fasten fixed shelving units to existing concerete slab. Use]J4" dia. screw to fasten base to 14 GA shelf member. USE: HILTI KWIK BOLT TZ ANCHOR (or equivalent) - (:= 5 USE 3/8"41 x 2" embed installed per the requirements of Hilti 3 / C; 1 Wall Supported - Combined Loading (Tsmax l Vsmax4� 'Usmax 0:01 + = <1.00 Shear Loading (Single Anchor)- = 0.1b � <1.00 Tas Vas OKAY (Single Anchor)- Vas OKAY nu. I Vsmax ;max 1 Tension Pullout Tsmax . Combined Loading • + 0.71• = 0.07 <1.00 = 0.36. <1.00 (Single Screw)- 1.10•Sts, Vasi Tasi ) OKAY (Single Screw)- Tsst OKAY 10 t% EC LI PS E BATH&BODY WORKS#780 21912017 ENGINEERING ARCADIA,CA Rolf Armstrong,PE Connection from Steel Racks to Wall Seismic Analysis Procedure per ASCE-7 Section 13.3.1: Average Roof Height- hr= 36 ft Height of Rack Attachments- zb:= z+ ht zb= lO ft (At Top for fixed racks connected to walls) Seismic Base Shear Factor- Vt 0.4 ap Sos (I1+ 2. zb Vt= 0.68 Rp hr) Ip Shear Factor Boundaries- Vtmin 0.3•SEG.Ip= 0.524 Vtmax:= 1.6•SIDS.Ip = 2.797 Seismic Coefficient- Vt:= min(max(Vtmin,Vt),Vtmax) = 0.68 Number of Shelves- N = 5 Weight per Shelf- Wtl= 100 lb Total Weight on Rack- WT:= 4.(Pd + 0.67.Pi) WT= 440.63 lb 0.7.Vt.WT Seismic Force at top and bottom- Tv:= Tv= 104.83 lb 2 Connection at Top: Standard Stud Spacing- Sstud 16.in Width of Rack- w= 4 ft Number of Connection Points on each rack- Force on each connection point- Nc:= maxr2,(floor(w 111 = 3 Fc:= Tv = 34.94 lb L �Sstud JJJ Nc Capacity per inch of lb Required Fc W := 135•— d := — = 0.259.in embedment into wood Nailer- s in Embedment Depth- s W S For Steel Studs: Pullout Capacity for#10 Screw Ratio of Allowable Loads Fc MUST BE in 20 ga studs(per Scafco)- T20:= 84•Ib for screws into walls- T20 = 0 '42 <1.0 Connection at Bottom: Ratio of Allowable Loads a Tv MUST BE for anchors into slab- 0.20 <1.0 0.7.Vas MIN #10 SCREW ATTACHED TO EXISTING WALL STUD IS ADEQUATE TO RESIST SEISMIC FORCES ON SHELVING UNITS. EXPANSION BOLT IS ADEQUATE AT THE BASE. 11 2/8/2017 Design Maps Summary Report USGS Design Maps Summary Report User-Specified Input , Building Code Reference Document ASCE 7-10 Standard (which utilizes USGS hazard data available in 2008) Site Coordinates 34.13492°N, 118.051°W Site Soil Classification Site Class D - "Stiff Soil" Risk Category I/II/III d �'7`' k ,. fir- R'�,, t ,.,-. � f,. ` ..La Canada r. k 'V kr - ,a ✓• J ti���.1 rFARpArta d -§ t-i a:� 'i '' e , ° t sf s Y 3 °+ . & -Y '1 ▪ z �t AI'taCi�'t�a l � g � �y ��, ! r � 1110'.Burbank ' ,M1•i -'''---:---17---0,";--:.: 1 kk s y 4 .' > ':: • 1" ,�", ! �„i_..-.. 'Y :A.;-44.0:•,,V)44 TMx ',X97 - fA + ° a, 1 l/ mo. ' f ril a,,, '- . . :: ala f C; �a : ,1-714;,'-'-?*'; y, t i i v zs :,,,,,,44444-:!,,i-5, 04 .sr� ( �' x, i `i�iiendal , x 5aerra Mare �s , ▪ , a,'.- I ;e ,e'n',.. t Iyy 11'i FDDL,11,al'I k ";�r- � i 3 �_ - t e S'�4 • 1 ?i. �.:,,<.. 1 r f T I A, , �- . el :z' a'r�. It .: , �al�Citytt r.r - �- -f'asaoena { 1i :-" S---Iowa . Glendorai 3+ ,,, - ` c i • , I �l i� ,I Arc call' �i r'puart -,Awsa .,. , I t r-; r' � k - South Pasadena !lk 'Sari Marino l� .4,-, r' 7-11:--:',... .r.,?,,*,------,_ I ra41` ▪ r J I k5 Temple City „- I. i 1i .it 11h\t .� a.`�- Ai11+7mbr� l(` it I� ( _,,, 1 3 -,-'---c-=----ti La V1 1`'i -, iP. •S�n Gabriel r s r ,-. '- 11 'w`4"�, pr: r ''.:Nle,';'''''': � s � v 1 Covina,,.. ll�'`vweot� I Roserne,pd 4tl ra°nt: Irro't i I �,Y � t �'� Baldwm,Park d _ �ti ti<; �`,.5, i 3 € r j -F-1, 1� 1 ;,r , . r 7, will iai / + = EI Iain e;� It }. „��s:t/k +� � '� j I il � .l' c,, __�.�p�.-:- r '�f�k$t C+�VIn d "-. _,,��1 �,�,r �. 7¢`f,n Jrl' Q<� '-...- 5 E, f��i011terey.l?slrkllit4:4'!./4//,-s,,, r 1 f tf_ _ �• f 3T P' ,1 t {rte 4J ! , -;.;.',•:,,„;?;' i ie� .r. +f South EI tvlonteQ, 5}ri.. E, 1 -w rt- ` 1 . ✓/7p "� IpY , V-.1 ▪Litc S iirlggl,es� }. Tin .n ,tria___+. := .__ = n!,� y___ > __._19 .'4;:,.' e` er _.. USGS-Provided Output Ss = 2.622 g SMS = 2.622 g SDS = 1.748 g S1 = 0.992 g SMS = 1.488 g SDS = 0.992 g For information on how the SS and Si values above have been calculated from probabilistic (risk-targeted) and deterministic ground motions in the direction of maximum horizontal response, please return to the application and select the"2009 NEHRP" building code reference document. MGER Response Spectrum Design Response Spectrum 1.92 2.70 1.20 . 2.43 1.62 2.16 1.44 1.29 1.25 ll 1.62 Si 1.02 y 1.35 i y 0. 90 i 1.02 0.72 0.21 0.54 0.54 0.35 0.27 0.12 0.00 0.00 0.00 0.20 0.40 0.50 0.20 1.00 1.20 1.40 1.60 1.130 2.00 0.00 0.20 0.40 0.50 0.20 1.00 1.20 1.40 1.50 1.20 2.00 Period.T(sec) Period. T(sec) For PGAM, TL, CRS, and CRS values, please view the detailed report. Although this information is a product of the U.S.Geological Survey,we provide no warranty,expressed or implied,as to the accuracy of the data contained therein.This tool is not a substitute for technical subject-matter knowledge. http://earthquake.usgs.gov/designmaps/us/sum mary.php?template=minimal&latitude=34.13492&longitude=-118.050997&siteclass=3&riskcategory=0&edition=a.. 1/1 General Product Information Consulting Engineers ' '- .° • Thickness - Steel Components Weld �CTaprmigacities Steel Thickness Table I # iff�S.t d` rt�i, s u p s;t Is•�3�it�n�i'�}� 1,• t a 1y; Thilw� �.ig ') 1� �1 I t� l�.tY�31a � '`1,< Wit . "i , 1 I)t M.i -'c ) 7�I i11g 11 ess•q )'. .b, •t r'a 1 Y ,I I ` 51i s - ,} f,c31 , _ J 18 I 0.0179 L 0.0188 0.0843 � -' 25 43EQS-- 0.0400 1 _57 65 L 639 1106 696 I 849 27 0.0269 , 0.0283 0.0796 22 43 0.0451 33 45 601 864 544 663 i D20 0.0179 I 0.0188 0.0844 1 20-Drywall 54 0.0566 1 50 65 I 1188 I 1566 9851202 30EQD ' 0.0223 0.0235 0 0820 20-Drywall 68 0.0713 ' 50 65 ' 1562 : 1972 1241 I 151.4__ 30 0.0296 I 0.0312 0 0781 1 20-Drywall 97 0.1017 I 50 65 I 1269 I 1269 2, 33EQS 0.0280 0.0295 0.0790 20-Structural 118 0.1242 50 65 1550 1550 _ 33 J 0.0329 __ 0.0346 - - 0.0764 v , 20-Structural 127 0.1337 50 65 I 1668 ; 1668 43EQS 0.0380 0.0400 0.0712 18 Table Notes 43 0.0428 0.0451 0.0712 18 1. Capacities based on AISI 5300-07 Section E2.4 for fillet welds and E2.5 for flare groove welds. ... ._ .. 2. When connecting materials of different steel thicknesses or tensile strengths,use the values that , 54 0.0538 0.0566 0.0849 16 I correspond to the thinner or ----- -- - ----------- ---- --- -- -- -- - - -- lower yield material. 3. Capacities are based on Allowable Strength Designn(ASD)and include appropriate safety factors. 68 I 0.0677 0.0713 0.1069 1 14 4. Weld capacities are based on either V52"or ye"diameter E60 or E70 electrodes.For thinner --_ - materials,0.030"to 0.035"diameter wire electrodes may provide best results. 97 0.0966 0.1017 0.1525 12 5. Parallel capacity is considered to be loading in the direction of the length of the weld. 118 I 0.1180 0.1242 0.1863 I 10-SSMA 6. For welds greater than 1",equations E2.4-1 and E2.4-2 must be checked. -- 7. For flare groove welds,the effective throat of weld is conservatively assumed to be less than 2t. 127 0.1270 L 0.1337 0.2005 I 10-SCAFCO_J 8. *Flare grove weld capacity for material thicker than 0.10"requires engineering judgement to Table Notesdetermine leg of welds(W,and W,). 'Minimum thickness represents 95 percent of the design thickness and is the minimum acceptable thickness delivered to the jobsite based on Section A2.4 of AISI S100-07. 'The tables in this catalog are calculated based on inside corner radii listed in this table.The inside corner radius is the maximum of -t/2 or 1.5t,truncated after the fourth decimal place(t= design thickness).Centerline bend radius is calculated by adding half of the design thickness to listed corner radius. Screw Capacities Allowable Screw Connection Capacity(lbs per screw) FIA,5-6739t iA 73J'I tigiY. Piim §-07/ Ilf ago/ 'itl p13 ''-t111.4J 1 9{ 1,4 I),lIJJ 'itt.fj•ci-lrf':nl'j'1 .."1V'11-- 1 t " r3'1 ' 1):4!).-1)Dtrkti1)3-li7''rl�-i] 111}: ellji) i}t'41441'S1 'i} .5f!1.{5519,1 =)n!ii ^_10 7xaa _ r it la�1 ,r �7 � � 0 _ xt � I)3 7 Faf�xr�tt r rl �_ 18. . .I 33 _1 45. I 60 33 I 66 39 ��_ 71 , 46 I 4 76 I 52 I 81 I 60- . I 27 33 45 ' 111 50 122 59 131 69 139 78 150 90 D20 57 F 65 87 48 1 ._ 95 j 57 102 66 109 - 75 ,. 117 87 30EQD 57 65 122 t 60 `: 133 71 143 82 I 152 94 164 108 30 77 33 45 129 55 I 141 65 151 76 161 86 I 174100 100 . 33EQS 57 65 i 171 75 187 89 201 103 214 117 231 136 33 33 45 151 61 i 164 I 72 177 84 188 [ 95 1_ 203 110 43EQS 57 65 270 102 • 295 121 317 140 338 159 364 184 43 1 33 45 224 79 I. 244 94 263 _.....1_ 109 280 - i 124 _ 302 144 54 50 65 455 144 49.6 171 534 198 570 225 613 _ 261 68 50 65 576 181 I 684 215 755 250 805 284 I 866 328 97 50 65 821 259 - 976 307 1130 356 1285 405 - 1476 468 • 118 50 65 1003 316 I 1192 375 1 1381 435 1569 I 494 I 1816 572 • 127 50 65 1079 340 1283 404 1486 468 I 1689 532 1955 616 Table Notes - 1. Capacities based on AISI S100-07 Section E4.See table on page 5 for design thicknesses. 6. Tension capacity Is based on the lesser of pullout capacity in sheet closest to screw tip,or pullover 2. When connecting materials of different steel thicknesses or tensile strengths,use the lowest values. capacity for sheet closest to screw head(based on head diameter shown).Note that for all tension Tabulated values assume two sheets of equal thickness are connected. values shown in this table,pullover values have been reduced by 50 percent assuming eccentrically 3. Capacities are based on Allowable Strength Design(ASD)and Include safety factor of 3.0. loaded connections that produce a non-uniform pull-over force on the fastener. 4. Where multiple fasteners are used,screws are assumed to have a center-to-center spacing of at 7. Higher values,especially for screw strength,may be obtained by specifying screws from a specific least 3 times the nominal diameter(d) manufacturer.See manufacturer's data for specific allowable values and installation instructions. 5. Screws are assumed to have a center-of-screw to edge-of-steel dimension of at least 1.5 times the nominal diameter(d)of the screw. Load Paths • 3�,r , y= °, All product load capacities are calculated per North American a , z ',4'4,11 Specification for the Design of Cold Formed Steel Structural ' � a' 4 'f' ' ` 4 '',A :$W.- ''III Members. The 2007 edition (here after referred to as simply -,' s "NASPEC"). Illustrations of load instructions are amongst their relative product load tables located throughout this catalog. -•'" "- =�' Figure to the right demonstrates different types of load t= , x� directions mentioned in this catalog. ,, , y.`o ?. , c' Fl = Out-of-plane lateral load f �x 'L - 1 ^, - O iF2 = In-Plane lateral load r.: J;._ 7_; O F3 = Direct vertical and uplift load r._. �� s - < roI 5ccel 5[ud Comrany '> I Eclipse Engineering,Inc. Consulting Engineers 1141��1 ' MLG www.hilti.us Profis Anchor 2.4.6 Company: ECLIPSE ENGINEERING,INC. Page: 1 Specifier: Project: Address: Sub-Project I Pos.No.: Phone I Fax: 541-389-9659 I Date: 5/27/2014 E-Mail: Specifier's comments: 1 Input data Anchor type and diameter: Kwik Bolt TZ-CS 3/8(2) ,a,;�;;, ;a t 4,117.,;,s" Effective embedment depth: het,aat=2.000 in.,hnom=2.313 in. Material: Carbon Steel Evaluation Service Report: ESR-1917 Issued I Valid: 5/1/2013 15/1/2015 Proof: design method ACI 318-11 /Mech. Stand-off installation: -(Recommended plate thickness:not calculated) Profile: no profile Base material: cracked concrete,2500,fc'=2500 psi;h=4.000 in. Installation: hammer drilled hole,installation condition:dry Reinforcement: tension:condition B,shear:condition B;no supplemental splitting reinforcement present edge reinforcement:none or<No.4 bar Seismic loads(cat.C,D,E,or F) Tension load:yes(D.3.3.4.3(b)) Shear load:yes(D.3.3.5.3(a)) Geometry[in.]&Loading[Ib,in.lb] z gt 6 3o• Y X Input data and results must be checked for agreement with the existing conditions and for plausibility! PROFIS Anchor(c)2003-2009 Hilti AG,FL-9494 Schwan Hilti is a registered Trademark of Hilti AG,Schaan Eclipse Engineering,Inc. 1 1 `T1 Consulting Engineers MLG www.hilti.us Profis Anchor 2.4.6 Company: ECLIPSE ENGINEERING,INC. Page: 2 Specifier: Project: Address: Sub-Project I Pos.No.: Phone I Fax: 541-389-9659 I Date: 5/27/2014 E-Mail: 2 Proof I Utilization (Governing Cases) Design values[Ib] Utilization Loading Proof Load Capacity 13N I pv[%] Status Tension Pullout Strength 300 1107 28/- OK Shear Steel Strength 200 1466 -/14 OK Loading j3N fly Utilization 13N,v[%] Status Combined tension and shear loads 0.271 0.136 5/3 15 OK 3 Warnings • Please consider all details and hints/warnings given in the detailed report! Fastening meets the design criteria! 4 Remarks; Your Cooperation Duties • Any and all information and data contained in the Software concern solely the use of Hilti products and are based on the principles,formulas and security regulations in accordance with Hilti's technical directions and operating,mounting and assembly instructions,etc.,that must be strictly complied with by the user. All figures contained therein are average figures,and therefore use-specific tests are to be conducted prior to using the relevant Hilti product. The results of the calculations carried out by means of the Software are based essentially on the data you put in. Therefore,you bear the sole responsibility for the absence of errors,the completeness and the relevance of the data to be put in by you. Moreover,you bear sole responsibility for having the results of the calculation checked and cleared by an expert,particularly with regard to compliance with applicable norms and permits,prior to using them for your specific facility. The Software serves only as an aid to interpret norms and permits without any guarantee as to the absence of errors,the correctness and the relevance of the results or suitability for a specific application. • You must take all necessary and reasonable steps to prevent or limit damage caused by the Software. In particular,you must arrange for the regular backup of programs and data and,if applicable,carry out the updates of the Software offered by Hilti on a regular basis. If you do not use the AutoUpdate function of the Software,you must ensure that you are using the current and thus up-to-date version of the Software in each case by carrying out manual updates via the Hilti Website. Hilti will not be liable for consequences,such as the recovery of lost or damaged data or programs,arising from a culpable breach of duty by you. Input data and results must be checked for agreement with the existing conditions and for plausibility! PROFIS Anchor(c)2003-2009 Hilti AG,FL-9494 Schaan Hilti is a registered Trademark of Hilti AG,Schaan Eclipse Engineering,Inc. Consulting Engineers lim11,11.M'' MLG www.hilti.us Profis Anchor 2.4.6 • Company: ECLIPSE ENGINEERING, INC. Page: 1 Specifier: Project: Address: Sub-Project I Pos.No.: Phone I Fax: 541-389-9659 I Date: 5/27/2014 E-Mail: Specifier's comments: 1 Input data Anchor type and diameter: Kwik Bolt TZ-CS 3/8(2) 15,1ri, 1 1 Effective embedment depth: hef,act=2.000 in.,hnom=2.313 in. Material: Carbon Steel Evaluation Service Report: ESR-1917 Issued I Valid: 5/1/2013 15/1/2015 Proof: design method ACI 318-11 /Mech. Stand-off installation: eb=0.000 in.(no stand-off);t=0.074 in. Anchor plate: Ix x ly x t=3.000 in.x 6.500 in.x 0.074 in.;(Recommended plate thickness:not calculated) Profile: no profile Base material: cracked concrete,2500,fc'=2500 psi;h=4.000 in. Installation: hammer drilled hole,installation condition:dry Reinforcement: tension:condition B,shear:condition B;no supplemental splitting reinforcement present edge reinforcement:none or<No.4 bar Seismic loads(cat.C, D,E,or F) Tension load:yes(D.3.3.4.3(b)) Shear load:yes(D.3.3.5.3(a)) Geometry[in.]&Loading[Ib,in.Ib] z o 5.5 27S ' r 0, • t \\ X Input data and results must be checked for agreement with the existing conditions and for plausibility! PROFIS Anchor(c)2003-2009 Hilti AG,FL-9494 Schaan Hilti is a registered Trademark of Hilti AG,Schaan • . Eclipse Engineering,Inc. 111 Consulting Engineers , TilI MLG • www.hilti.us Profis Anchor 2.4.6 Company: ECLIPSE ENGINEERING,INC. Page: 2 Specifier: Project: Address: - Sub-Project I Pos.No.: Phone I Fax: 541-389-9659 I Date: 5/27/2014 E-Mail: 2 Proof I Utilization (Governing Cases) Design values[Ib] Utilization Loading Proof Load Capacity pN I liv[%] Status Tension Pullout Strength 150 1107 14/- OK Shear Concrete edge failure in direction x+ 200 1966 -/11 OK Loading RN j3v S Utilization j3N,v[%] Status Combined tension and shear loads 0.140 0.102 5/3 6 OK 3 Warnings • Please consider all details and hints/warnings given in the detailed report! Fastening meets the design criteria! 4 Remarks; Your Cooperation Duties • Any and all information and data contained in the Software concern solely the use of Hilti products and are based on the principles,formulas and security regulations in accordance with Hilti's technical directions and operating,mounting and assembly instructions,etc.,that must be strictly complied with by the user. All figures contained therein are average figures,and therefore use-specific tests are to be conducted prior to using the relevant Hilti product. The results of the calculations carried out by means of the Software are based essentially on the data you put in. Therefore,you bear the sole responsibility for the absence of errors,the completeness and the relevance of the data to be put in by you. Moreover,you bear sole responsibility for having the results of the calculation checked and cleared by an expert,particularly with regard to compliance with applicable norms and permits,prior to using them for your specific facility. The Software serves only as an aid to interpret norms and permits without any guarantee as to the absence of errors;-the correctness and the relevance of the results or suitability for a specific application. • You must take all necessary and reasonable steps to prevent or limit damage caused by the Software. In particular,you must arrange for the regular backup of programs and data and,if applicable,carry out the updates of the Software offered by Hilti on a regular basis.If you do not use the AutoUpdate function of the Software,you must ensure that you are using the current and thus up-to-date version of the Software in each case by carrying out manual updates via the Hilti Website. Hilti will not be liable for consequences,such as the recovery of lost or damaged data or programs,arising from a culpable breach of duty by you. • TENSION LOAD & CAPACITY SHOWN ARE "PER ANCHOR" VALUES. SHEAR LOAD & CAPACITY SHOWN ARE "PER ANCHOR PAIR" VALUES. Input data and results must be checked for agreement with the existing conditions and for plausibility! PROFIS Anchor(c)2003-2009 Hilti AG,FL-9494 Schaan Hilti is a registered Trademark of Hilti AG,Schaan Eclipse Engineering,Inc. Consulting Engineers 1.11,111jr1111" MLG www.hilti.us Profis Anchor 2.4.6 Company: ECLIPSE ENGINEERING,INC. Page: 1 Specifier: Project: Address: Sub-Project I Pos.No.: Phone I Fax: 541-389-9659 1 Date: 5/27/2014 E-Mail: Specifier's comments: 1 Input data Anchor type and diameter: KWIK HUS-EZ KH-EZ 3/8(2 1/2) X Effective embedment depth: het,act=1.860 in.,hnom=2.500 in. Material: Carbon Steel Evaluation Service Report: ESR-3027 Issued I Valid: 8/1/2012 1 12/1/2013 Proof: design method ACI 318-11/Mech. Stand-off installation: -(Recommended plate thickness:not calculated) Profile: no profile Base material: cracked concrete,2500,fc'=2500 psi;h=4.000 in. Installation: hammer drilled hole,installation condition:dry Reinforcement: tension:condition B,shear:condition B;no supplemental splitting reinforcement present edge reinforcement:none or<No.4 bar Seismic loads(cat.C, D, E,or F) Tension load:yes(D.3.3.4.3(b)) Shear load:yes(D.3.3.5.3(a)) Geometry[in.]&Loading[Ib,in.Ib] z A g wl 6 e__„---Tr- 4# _ h^� • • ,X Input data and results must be checked for agreement with the existing conditions and for plausibility! PROFIS Anchor(c)2003-2009 Hilti AG,FL-9494 Schaan Hilti is a registered Trademark of Hilti AG,Schaan Eclipse Engineering,Inc. Consulting Engineers MLG www.hilti.us Profis Anchor 2.4.6 Company: ECLIPSE ENGINEERING,INC. Page: 2 Specifier: Project: Address: Sub-Project I Pos.No.: Phone I Fax: 541-389-9659 I Date: 5/27/2014 E-Mail: 2 Proof I Utilization (Governing Cases) Design values[Ib] Utilization Loading Proof Load Capacity Jv[%J Status Tension Concrete Breakout Strength 300 1051 29/- OK Shear Pryout Strength 200 1509 -/14 OK Loading ON Dv Utilization DNA,[%] Status Combined tension and shear loads 0.285 0.133 5/3 16 OK 3 Warnings • • Please consider all details and hints/warnings given in the detailed report! Fastening meets the design criteria! • 4 Remarks; Your Cooperation Duties • Any and all information and data contained in the Software concern solely the use of Hilti products and are based on the principles,formulas and security regulations in accordance with Hilti's technical directions and operating,mounting and assembly instructions,etc.,that must be strictly complied with by the user. All figures contained therein are average figures,and therefore use-specific tests are to be conducted prior to using the relevant Hilti product. The results of the calculations carried out by means of the Software are based essentially on the data you put in. Therefore,you bear the sole responsibility for the absence of errors,the completeness and the relevance of the data to be put in by you. Moreover,you bear sole responsibility for having the results of the calculation checked and cleared by an expert,particularly with regard to compliance with applicable norms and permits,prior to using them for your specific facility. The Software serves only as an aid to interpret norms and permits without any guarantee as to the absence of errors,the correctness and the relevance of the results or suitability for a specific application. • You must take all necessary and reasonable steps to prevent or limit damage caused by the Software. In particular,you must arrange for the regular backup of programs and data and,if applicable,carry out the updates of the Software offered by Hilti on a regular basis. If you do not use the AutoUpdate function of the Software,you must ensure that you are using the current and thus up-to-date version of the Software in each case by carrying out manual updates via the Hilti Website. Hilti will not be liable for consequences,such as the recovery of lost or damaged data or programs,arising from a culpable breach of duty by you. Input data and results must be checked for agreement with the existing conditions and for plausibility! PROFIS Anchor(c)2003-2009 Hilti AG,FL-9494 Schaan Hilti is a registered Trademark of Hilti AG,Schaan Eclipse Engineering, Inc. ,L ,'.., Consulting Engineers MLG www.hilti.us Profis Anchor 2.4.6 Company: ECLIPSE ENGINEERING Page: 1 Specifier: Project: Address: Sub-Project I Pos.No.: Phone I Fax: 541-389-9659 I Date: 5/27/2014 E-Mail: Specifier's comments: 1 Input data Anchor type and diameter: KWIK HUS-EZ KH-EZ 318 2 112 �ti �� g—__�rd ° Effective embedment depth: hef,ae=1.860 in.,hnom=2.500 in. -- Material: Carbon Steel Evaluation Service Report: ESR-3027 Issued I Valid: 8/1/2012 112/1/2013 Proof: design method ACI 318-11 /Mech. Stand-off installation: eb=0.000 in.(no stand-off);t=0.074 in. Anchor plate: Ix x ly x t=3.000 in.x 7.000 in.x 0.074 in.;(Recommended plate thickness:not calculated) Profile: no profile Base material: cracked concrete,2500,fc'=2500 psi;h=4.000 in. Installation: hammer drilled hole,installation condition:dry Reinforcement: tension:condition B,shear:condition B;no supplemental splitting reinforcement present edge reinforcement:none or<No.4 bar Seismic loads(cat.C,D,E,or F) Tension load:yes(D.3.3.4.3(b)) Shear load:yes(D.3.3.5.3(a)) Geometry[in.]&Loading[Ib,in.ib] z w�S Cao 5$ S 27$* r--' z o . 0 X Input data and results must be checked for agreement with the existing conditions and for plausibility! PROFIS Anchor(c)2003-2009 Hilti AG,FL-9494 Schaan Hilti is a registered Trademark of Hilti AG,Schaan Eclipse Engineering,Inc. Consulting Engineers MLG www.hilti.us Profis Anchor 2.4.6 .Company: ECLIPSE ENGINEERING Page: 2 Specifier: Project: Address: Sub-Project I Pos.No.: Phone I Fax: 541-389-9659 i Date: 5/27/2014 E-Mail: 2 Proof I Utilization (Governing Cases) Design values[Ib] Utilization Loading Proof Load Capacity j3N/pv[%] Status Tension Concrete Breakout Strength 300 1993 16/- OK Shear Concrete edge failure in direction x+ 200 1938 -/11 OK Loading j3N 13v Utilization DNA,[%] Status Combined tension and shear loads 0.151 0.103 5/3 7 OK 3 Warnings • Please consider all details and hints/warnings given in the detailed report! Fastening meets the design criteria! 4 Remarks; Your Cooperation Duties • Any and all information and data contained in the Software concern solely the use of Hilti products and are based on the principles,formulas and security regulations in accordance with Hilti's technical directions and operating,mounting and assembly instructions,etc.,that must be strictly complied with by the user. All figures contained therein are average figures,and therefore use-specific tests are to be conducted prior to using the relevant Hilti product. The results of the calculations carried out by means of the Software are based essentially on the data you put in. Therefore,you bear the sole responsibility for the absence of errors,the completeness and the relevance of the data to be put in by you. Moreover,you bear sole responsibility for having the results of the calculation checked and cleared by an expert,particularly with regard to compliance with applicable norms and permits,prior to using them for your specific facility. The Software serves only as an aid to interpret norms and permits without any guarantee as to the absence of errors,the correctness and the relevance of the results or suitability for a specific application. • You must take all necessary and reasonable steps to prevent or limit damage caused by the Software. In particular,you must arrange for the regular backup of programs and data and,if applicable,carry out the updates of the Software offered by Hilti on a regular basis.If you do not use the AutoUpdate function of the Software,you must ensure that you are using the current and thus up-to-date version of the Software in each case by carrying out manual updates via the Hilti Website. Hilti will not be liable for consequences,such as the recovery of lost or damaged data or programs,arising from a culpable breach of duty by you. Input data and results must be checked for agreement with the existing conditions and for plausibility! PROFIS Anchor(c)2003-2009 Hilti AG,FL-9494 Schaan Hilti is a registered Trademark of Hilti AG,Schaan ___ CERTIFIED WELDER License*. P030724 4 i- - --GABINO-JESSY L. aMEJ1A STRUCTURAL-MANUAL-PROCESS;•' .1' ' .x STRUCTURAL-SEMIAUTOMATIC . f issued by City of Los Angeles :-.-,t;?,,.,,-,,..',.74%-3,-,,fi t )Department of Building and Safety :'1-= , _„„--4,_. ;, .. ,-;-> -0 ''',- ,,,f 4., , ,',,,TO-,,, , 4, ,'..,,4,4-,fr, r ,01,• I Co 0 0 ,--*-- , 1.7 ' ,i..' -,e, `,.'-''''',.:2' ' '''",.....,t_ ' 1:4•1'44,..ty,'-tt, ,,,, , ci0 (1)- il o 3 co = 2- irc CERTIFIED WELDER I. License #: P030724 0 go GABINO JESSY L. MEJ1A N) .... STRUCTURAL-MANUAL PROCESS — ..) STRUCTURAL-SEMI Lo AU i 0 • -r e-, t 1 0 0 0 ., .1_.. (D (0 c , k""1 Issued by City of Los Angeles ...41 • it 1140- 1 i.. * *•./ Department of Building and Safety 4 CONTRACTORS C:=I= STATE LICENSE BOARD t— wim ACTIVE LICENSE _ 961365 CORD A & R WELDING INC DBA A & E WELDING CCC .441ht.. 05/31/2019 vvww cslb ca gov