Loading...
HomeMy WebLinkAboutUntitled Ill ' , ,. City of Arcadia, CA _ Permit-NO.SOLR 18-0. 153i\ , . Development Services Department �� ` ' - Permit Type.Solar 1i 240 West Huntington Drive,Post Office Box 60021 i t Arcadia,CA 91066-6021 V ` .-; = ) i I ; ' , Work Classificdhon:Residential Solar (626)574-5416 � /t - -Perrrm' Status:Issued ARCADIA Issue Date 02/15/2018 Expiration: 08/14/2018 Addr NO. Dir Prefix Street Name Street Suffix City,State,Zip Parcel Number 300 E Forest AVE Arcadia,CA 5772022026 Contacts HUANG,KANG AND GRACE Y Owner LA SOLAR GROUP INC. Solar Contractor(C-46) 1 300 E FOREST AVE 16238 RAYMER ST B,VAN NUYS,91406 (626)377-3079 (818)455-9293 Description:ROOF MOUNTED SOLAR SYSTEM 13 PANELS 1 Valuation: $0.00Tenant INVERTER Total Sq Feet: 0.00 k Plan Check# Plan# Fees Amount Payments Amount Paid Building Plan Check Fee Residential $50.00 Total Fees $300.91 Electrical Permit Issuance Fee $44.35 Cash/Receipt# $300.91 Fire Plan Check Fee Residential $50.00 Amount Due: Inverters $77.78 $0.00 Panels $77.78 Solid Waste Management Fee 2 $1.00 Total: $300.91 Insert a permit notice prefix in the report text bank,entry: 2.—Z7---1 g 1---/et,4-L '77. Permit_Notice_Prefix This permit/plan review expires by time limitation and becomes null and void if the work authorized by the permit is not commenced within 180 days from the date of issuance or if the permit is not obtained within 180 days from the date of plan submittal.This permit expires and becomes null and void if any work authorized by this permit is suspended or abandoned for 180 consecutive days or if no progressive work has been verified by a City of Arcadia building inspector for a period of 180 consecutive days. qi February 15, 2018 Issued By: Date ei COMPLETES February 15,2018 Insert a permit page footer in the report text bank,entry:Permit_Page_Footer Page 1 of 2 OF ARC 11110111! i, PERMIT/PLAN REVIEW APPLICATION o , Development Services Department,240 West Huntington Drive,Post Office Box 60021 mm4o,,,ofv Arcadia, CA 91066-6021, (626) 574-5416,Fax(626) 447-9173 City of Arcadia ENSED CONTRACTOR'S DECLARATION WORKERS'COMPENSATION DECLARATION .0 I hereby affirm under penalty of perjury that I am licensed under provisions of I hereby affirm under penalty of perjury one of the following: Chapter 9(commencing with Section 7000,of Division 3 of the Business and Professions Code,and my license is in full force and effect. ❑ I have and will maintain a certificate of consent to self-insure for workers' � License ClassC "OifGiC e�nse Not—NjtExp. Date t ( Signature of Contractor compensation, as provided for by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. OWNER-BUILDER DECLARATION I have and will maintain workers'compensation insurance,as required by Section ❑ I hereby affirm under penalty of perjury that I am exempt from the Contractors 3700 of the Labor Code,for the performance of the work for which this permit License Law for the following reason(Section 7031.5,Business and Professions is issued.My workersvcompensation insurance carrier and policy numbers are: Code.Any city or county which requires a permit to construct,alter,improve, Carrier '1 'l o�a demolish,or repair any structure,prior to its issuance,also required the applicant Vf....1 tAtls)C C7 ne't 5€,(O for such permit to file a signed statement that he or she is licensed pursuant to the Policy Number provisions of the Contractors License Law(Chapter 9(commencing with Section (Ts section need not be completed if the permit is for one hundred dollars or less) 7000) of Division 3 of the Business and Professions Code) or that he or she is exempt there from and the basis for the alleged exemption. Any violation of ❑ I certify that in the performance of the work for which this permit is issued,I shall Section 7031.5 by any applicant for a permit subjects the applicant to a civil not employ any person in any manner so as to become subject to the workers' penalty of not more than five hundred dollars($500)): compensation Laws of California,and agree that if I should become subject to the workers'compensation provisions of Section 3700 of the Labor Code,I shall ❑I, as owner of the property, or my employees with wages as their sole forthwith comply with those provisions. compensation,will do the work,and the structure is not intended or offered for 2 • 1'S •l`O sale(Section 7044,Business and Professions Code:The Contractors License Date Signature Law does not apply to an owner of property who builds or improves thereon, or who does such work himself or herself or through his or her own employees,provided that such improvements are not intended or offered for WARNING: Failure to secure Workers'Compensation coverage is unlawful, sale.If,however,the building or improvement is sold within one(1)year of and shall subject an employer to criminal penalties and civil fines up to one completion,the owner-builder will have the burden of proving that he or she hundred thousand dollars($100,000),in addition to the cost of compensation, did not build or improve for the purpose of sale). damages as provided for in Section 3706 of the Labor Code, interest, and attorney's fees. - ❑I, as owner of the property, am exclusively contracting with licensed contractors to construct the project(Section 7044,Business and Professions Code:The Contractors License Law does not apply to an owner of property CONSTRUCTION LENDING AGENCY who builds or improves thereon,and who contracts for such projects with a I hereby affirm under penalty of perjury that there is a construction lending agency contractor(s)licensed pursuant to the Contractors License Law). for the performance of the work for which this permit is issued (Section 3097, Civil Code). ❑ I am exempt under Section 7044,Business and Professions Code,for this reason: Lender's Name Date Signature Lender's Address IMPORTANT: APPLICATION IS HEREBY MADE TO THE BUILDING OFFICIAL FOR A PERMIT SUBJECT TO THE CONDITIONS AND RESTRICTIONS SET FORTH ON THIS APPLICATION AND THE FOLLOWING: 1. The City's approved plans and permit inspection card must remain on the job site for use by City inspection personnel. 2. Final inspection of the work authorized by this permit is required.A Certificate of Occupancy must be obtained prior to use and occupancy of new buildings and structures. 3. Per South Coast Air Quality Management District(AQMD)regulations,renovation and remodeling work that results in the removal,stripping,or altering of asbestos containing materials requires an asbestos survey and removal prior to disturbing the asbestos.Please contact AQMD at(909)396-2000 for further information. `� ‘Tame "`� ` Title n r ' PRINT NAME I certify that I have read this application and state that the above information is correct and that I am the owner or duly authorized agent of the owner. I agree to comply with all City ordinances and State Laws relating to building construction. I hereby authorize representatives of the City of Arcadia to enter upon the above-mentioned property for inspection purposes. - CSignature (Date oPLj`►y1�\. y°+ xx ,\ ; t \ Aa¢ f 1¢ AFFI;r'NIT SELF=CCF%TtFlCATiON FOR COMPUUACI 0,F SMOE(C ALARMS, . AND C ,'t,BON MON oXIDE Air e'':MS Property Address: . : C: k : Mert Ade , - ACalko► OA Permit Number: 501-g :. tg-06.3 . t pr— Brief Job:Description: a- \ o.e= . 1a( $ Number of smoke alarms installed: 14 Number of carbon monoxide alarms installed: tf When alterations, repairs or additions requiring a permit occur, orsleeping roomsare created, Smoke alarms shall be installed in each..sleeping room, and outside each separate sleeping area in the immediate vicinity of the bedrooms, and oneach additional story of the dwelling, including basements and habitable attics as required by Section R314 of the 2016 California Residential Code (CRC) and California Health and Safety Code Section 11.3113.1. For dwellings or sleeping units containing fuel burning appliances or having attached ' garages, carbon monoxide alarms shall be installed outside each separate sleeping area in the immediate vicinity of the bedrooms, and on each additional story of the dwelling, including basements as required by Section R315 of the of the 2016 California Residential Code (CRC). Multi-purpose alarms (combination carbon monoxide andsmoke alarms) may be used. All alarms shall comply with requirements for listing and approval by the Office of the State Fire Marshal. http://osfm:fire.cagov/licensinglistinqs/licenselistino bml searchcotest.php As owner of the above referenced property, I hereby certify that the smokealarms and carbon monoxide alarms have been installed in accordance with the manufacturer's instructions and in compliance withthecode sections referenced above. I decl,;,re under penalty of perjury that t1 a f•rei•,®i g is true and corr .cf, and that this decl irati< n was executed.( n (Date) 0Q/-.6 /= at Arc=idia, Californi::e (owner's Name(printed/typed)° Q61� 4CCan� lr C1Ce Signature ;f Own re _ ":°..--ot--- -- This affidavit must be returned to the.City of Arcadia inspector prior to final inspection SIAi*r'E Alr.,i.*,1n4..fi,,ND Cr1„ j®N01S'IIlo)NO'Xt if_,4:\).ARM 1 tc..1 0)*.'-S +R ;L �, __ J ' Storage • • �Fmit�� Room .. > Garage FL,'ST.FLOOR PLAN . SMOKE AL \"M . III = CAR-;ON M 0 NOXI!E ALARM. , -a Bath - i 1 ,: ' Master Bedroom Dining Room ! Kaden -i I - i � • Han .. closet 1 1 Closet -r=-1 CloSCt i -moi i4111� ti ' Family hootri ;�u 1; --__ I edroona I3edroonl I . � - -- — SCONIFLORPLA Generamon 0 510' CONTRACTOR: 130'-4" LA Solar Group �p C 16236 8 Raymer St., • D Van Nuys,CA 91406 J LIC neTY E.818)46-0077 CI0, I p d /• LIC TYPE:C-46,C-10,C-39 � d 9 Llc#97H76 . \ ` 9 DRIVEWAY, 8TO A ° I . . • •A r LA9®L68A ////�//� Ara Petrosyan— o / / . 0. � / // // :///////, / 51-3" IN 14'-10" // * * * • • • * • • *ir IN . . . . . *. MSP t PROPERTY 121'-5" PLAN PROPERTY LINE ' g a t i ' d• ~ \ , ,_„.4.7...k..---ai -p' , m. �b 3 � '"` �. 41 ,R � {�•� Drawn By: 4,' lit. ,, I .., '.,;74, . ,, , Ara Petrosyan ' "-- ,.. " Grace and Kang Huang 8,LEGEND :, ,, y 300 E Forest Ave., Arcadia,CA 91006 MSP Main Service Panel . r AC AC Disconnect s + � *�. L IN Inverter , ` az iHmccreo 2/8/2018 ►��eftilkyoursolarptanscom. omit ENGINEERING SOLUTIONS FOR ALL YOUR SOLAR NEEDS Structural Calculations for SOLAR POWER SYSTEM CONNECTION CHECK AT: 300 E.Forest Ave. Arcadia,CA 91006 Job: Huang,Grace&Kang Prepared For: LA Solar Group 16238 B Raymer Street Van Nuys,CA 91406 (818)373-0077 Design Criteria 1- Code: CALIFORNIA BLDG CODE 2016/ASCE 7-10 2-Wind: 110 MPH,Exposure:C 3 -Wood Species:Douglas Fir Larch(G=0.5) Notice:Use restrictions of these calculations. The attached Calculations are valid only when bearing original signature hereon,photocopy is void. Contractor/Client to verify existing dimensions/conditions prior to construction. The use of these calculations is solely intended for the above mentioned project. QcoFESs/C ��sz.0 G TRUE c��2 Q NO.C70784 d EXP.06/30/2019 rn Al • V11. \" !vF 1-844-PV ELITE I info@yoursolarplans.com 3000 E.Birch Street Suite 201 I Brea CA 92821 } WIND LOADING ANALYSIS - Roof Components and Cladding Per ASCE 7-10 Code for Bldgs. of Any Height with Gable Roof 0 <=45°or Monoslope Roof 0 <=3° Using Part 1 &3: Analytical Procedure (Section 30.4 &30.6) Job Name: Huang, Grace& Kang Subject: Job Number: Originator: Checker: Input Data: A Wind Speed, V= :` .110':` 'mph (Wind Map, Figure 26.5-1A-C) 3ldg. Classification =.: II _;:-..(Table 1-1 Occupancy Category) Exposure Category =_. C ;: (Sect. 26.7) B Ridge Height, hr= 16.19: ft. (hr>= he) Eave Height, he=`:;;,;.:8:00= ` ft. (he <= hr) Building Width = ..:;45.00 : ft. (Normal to Building Ridge) Building Length = 50 00 I'ft. (Parallel to Building Ridge) I L Roof Type Gable .(Gable or Monoslope) Plan �I Topo. Factor, Kzt=: :1,.00,: (Sect. 26.8 & Figure 26.8-1) Direct. Factor, Kd = 0 85 ; (Table 26.6) Enclosed'? (Y/N) >= :Y (Sect. 28.6-1 & Figure 26.11-1) Hurricane Region'? N 0 0 Component Name= :Fastener (Purlin, Joist, Decking, or Fastener) hr Effective Area, Ae= 242';;:::'ft.^2 (Area Tributary to C&C) he Overhangs'? (Y/N) N (if used, overhangs on all sides) L Resulting Parameters and Coefficients: Elevation Roof Angle, 0= 20.00 deg. Mean Roof Ht., h = 15.00 ft. (h = (hr+he)/2, for roof angle >10 deg.) Roof External Pressure Coefficients, GCp: 3Cp Zone 1-3 Pos. = 0.30_ (Fig. 30.4-2A, 30.4-2B, and 30.4-2C) GCp Zone 1 Neg. = -0.80 (Fig. 30.4-2A, 30.4-2B, and 30.4-2C) GCp Zone 2 Neg. = -1.20_ (Fig. 30.4-2A, 30.4-2B, and 30.4-2C) GCp Zone 3 Neg. = -2.00 (Fig. 30.4-2A, 30.4-2B, and 30.4-2C) Positive& Negative Internal Pressure Coefficients, GCpi (Figure 26.11-1): +GCpi Coef. = 0.18_ (positive internal pressure) -GCpi Coef. _ -0.18 (negative internal pressure) If z <= 15 then: Kz =2.01*(15/zg)^(2/a) , If z > 15 then: Kz=2.01*(z/zg)^(2/a) (Table 30.3-1) a= 9.50 (Table 26.9-1) zg = 900 _ (Table 26.9-1) Kh = 0.85 (Kh = Kz evaluated at z= h) Velocity Pressure: qz = 0.00256*Kz*Kzt*Kd*V^2 (Sect. 30.3.2, Eq. 30.3-1) qh = 22.35 psf qh = 0.00256*Kh*Kzt*Kd*VA2 (qz evaluated at z = h) Design Net External Wind Pressures (Sect. 30.4 & 30.6): For h <=60 ft.: p= qh*((GCp) -(+/-GCpi)) (psf) For h > 60 ft.: p= q*(GCp) -qi*(+/-GCpi) (psf) where: q = qh for roof qi =qh for roof(conservatively assumed per Sect. 30.6) i. Wind Load Tabulation for Roof Components &Cladding Component z Kh qh p = Net Design Pressures(psf) (ft.) (psf) ?one 1,2,3 (+ Zone 1 (-) Zone 2 (-) Zone 3 (-) Fastener _ 0 0.85 _22.35 10.73 -21.90_ -30.84_ -48.72 15.00_ 0.85 _22.35 _ 10.73 -21.90 - -30.84 -48.72 For z= hr: 16.19 0.85 22.35 10.73X21.90 -30.84 -48.72 For z = he: 8.00_...._ 0.85 - 22.35 10.73 _ -21.90 30::84 ;` -48.72 For z= h: 15.00 0.85 22.35 10.73 -21.90 ::':... 3.01:84;i;- -48.72 Notes: 1. (+) and (-) signs signify wind pressures acting toward &away from respective surfaces. 2. Width of Zone 2 (edge), 'a' = 4.50 ft. 3. Width of Zone 3 (corner), 'a' = 4.50 ft. 4. For monoslope roofs with 0 <= 3 degrees, use Fig. 30.4-2A for'GCp' values with 'qh'. 5. For buildings with h > 60' and 0 > 10 degrees, use Fig. 30.6-1 for'GCpi' values with 'qh'. 6. For all buildings with overhangs, use Fig. 30.4-2B for'GCp' values per Sect. 30.10. 7. If a parapet>= 3' in height is provided around perimeter of roof with 0 <= 10 degrees, Zone 3 shall be treated as Zone 2. 8. Per Code Section 30.2.2, the minimum wind load for C&C shall not be less than 16 psf. 9. Reference: a. ASCE 7-10, "Minimum Design Loads for Buildings and Other Structures". b. "Guide to the Use of the Wind Load Provisions of ASCE 7-10" by: Kishor C. Mehta and James M. Delahay (2004). Roof Components and Cladding: in — !if_ r3 p .3 I'6 a/9.,, f' 1 l t {. 3 t 1 1 i I i r. I ( i 1 I r { :. t 1 I x i !1 lit 5 J_ 000a 1 0 <= 7 deg. 7 deg. < 0 <= 27 deg. 27 deg. < 0 <=45 deg. Roof Zones for Buildings with h <= 60 ft. (for Gable Roofs <=45°and Monoslope Roofs<= 3°) I . I 1 a i 1 1 1 6 1 1 ROOF PLAN Roof Zones for Buildings with h > 60 ft. . (for Gable Roofs<= 10°and Monoslope Roofs <= 3°) Gravity Load Data Panel Data Panel:. Panasonic330 Watt: Number of Modules::.;. 73: :.;.:... Racking System: UNIRAC Weight of PV Module.,40:8 lbs PV Module Dimensions L=`,64:5:.in W=::41:5;in Roof Data Roof Material::: :.;Shingle Roof Dead Load QD 12_psf PV System Dead Load Qpv= 3 psf Framing Spacing sroof= ;'24 in Linear Dead Load wD=(QD+Qpv)*sroof= 30 plf LagScrew Check Lumber:: DF L No..2 Uplift Demand Design Wind Pressure p= -30.8 psf(Zone 2) Trib. Depth for Each Rail dpv=U2= 2.69 ft Trib. Depth for Each Rail bpv=W/2= 1.73 ft Screw Anchor Spacing spv=..:.`:.; 6:.ft(max.) Uplift Force on Each Screw, Portrait UL=(p+Qpv)*dpv*Spy= -449 lbs(Upwards) Uplift Force on Each Screw,Landscape Uw=(p+Qpv)*bp„*spv= -289 lbs(Upwards) Design Uplift Force Pupllft=0.6*[Max(UL,UW)]= -269 lbs(Upwards) Uplift Capacity NDS 2015 Adjustment Factors CD= 1.6 CM= 1 Ct= 1 SG= 0.50 Co, Ceg, Cg, Cel, Ch,are not appicable Speicfic Gravity of Lumbei SG= 0.50 NDS Supplement Table 4a Diameter of Lag Screw D= :::: :5116.in Withdraw Design/in 1800*SG"2*D'm= 266 lbs/in NDS 2015 12.1-1 Depth of Embeddment Ip=.;: :2:50:in Total Nominal Withdrawal Value W=W*Ip= 665 lbs Withdrawal Design Vaule W=W*CD*CM*Ct= 1064 lbs NDS 2015 Table 11.3.1 Demand-Capacity Ratio Pupllft I W = 0.25 < 1 [OKAY] Beam/Top Chord Check Lumber:DF-L No.2 Moment Demand Span: 1 2 Orientation j (ft) pi(lbs) Lenght(ft): 11.5 11.5 1 3.8 -449 Portrait 2 7.6 -449 Portrait 3 9.1 -449 Linear Dead Load wd= 30 plf 4 13.0 -449 Wind Load, Portrait UL= -449 lbs 5 14.5 -449 Portrait Wind Load, Landscape Uw= -289 lbs 6 18.4 -449 #of Attachment per Rafter NA= wdx2 M(x)=Ri(x—Li)—Piix—ll)— 2000 —__,__ $ 1000 ly _r___ ......_.;. — 0 _ 010 50 • 1‘ 0 150 200 25.0 -1000 I-- o i 2 -2000 '_._._ .:____. i -3000 :. ._. _____, i..__.___._.__.::._._t_._ .._--_<..__.:..__ ._ ._.__..__:_.. ._._.._._ _._.• _ Length x(ft) M8f Moment Dead 752 lb-ft Dead+Wind 1881 lb-ft Dead+Snow 752 lb-ft Moment Capacity Framing Member Size 2x8: Lumber Grade: DF-L No. 2 CM= 1 C,= 1 Cr= 1.15 CF= 1.5 ft= 900 psi Cf,and Clare not applicablk Breadth b= 1.50 in Depth d= 7.25 in Section Modulus SX =bd2/6= 13.14 in3 Bending Stress Capacity Fb= CM*Ct*Cr*CF*fb= 1553 psi Table 4.3.1 NDS 2015 Co Fb'=Co*Fb Ma*Sx ASD Load Design Bending DCR Dead 0.9 1397 psi 687 psi D 687 psi 0.49 OKAY Dead+Wind 1.6 2484 psi 1718 psi .6W+.6D 1031 psi 0.41 OKAY Dead+Snow 1.15 1785 psi 687 psi D+S 687 psi 0.38 OKAY Deflection Limit E= 1600 ksi I= 47.63 in4 Transient Deflection 0.119 in Transient Deflection Allowed 1160 > 180 [OKAY] Total Deflection 0.283 in Total Deflection Allowed 487 > 120 [OKAY] • SEISMIC WEIGHT COMPARISON/ANALYSIS -(PER CBC 2016 Part 10 Chapter 4 Section 402 PV System Weight Module Model Panasonic 330 Watt Panel Weight Wpanel = 40.81 Number of Panels Npv= 13 lbs Total PV System Weight WpV=Wpanel * Npv= 530.53 lbs Existing Roof Weight Roof Weight QD= 12.0 psf Building Length Lbuiid = 50 ft Building Width Wbuild = 45 ft Roof Area Abuild= 2250 ft2 Building Perimeter Pbuiid= 190 ft Wall Height ht= 8 ft Wall weight QwaII= 15 psf Interior wall weight Qint= 10 psf Floor Load Wfloor=Abuild *QD= 27000 lbs Wall Load Aiwa= ht/2 *Qwall*Pbuild +Abuiid *Qint/2 = 22650 lbs Total Story Weight WbuiId =Wfloor+Wwali= 49650 lbs Percentage Weight Increa: Wpv/Wbuiid = 1.07% < 10% OKAY