Loading...
HomeMy WebLinkAboutUntitled t City of Arcadia, CA , _ ,u , 4 Permit,NO. EIec-18-0252 , Development Services Department : k m permit Type Electrical 240 West Huntington Drive,Post Office Box 60021 r` ( )! t Arcadia,CA 91066-6021 , _ , i ; f Work Classification Electrical Residential (626)574-5416 £ �, ` p 4: e ,, Permit Status:Issued ARCADIA Issue Date 03/06/2018 Expiration: 09/01/2018 Addr NO. Dir Prefix Street Name Street Suffix City,State,Zip Parcel Number 1267 Oakglen AVE Arcadia,CA 5771025010 Contacts MAY WONG Owner LA SOLAR GROUP INC. Solar Contractor(C-46) 1267 OAKGLEN 16238 RAYMER ST B,VAN NUYS,91406 (818)455-9293 1 Description:1 TESLA POWERWALL BATTERY BACK UP AND 200 :` Valuation: S 0.00 Tenant AMP SUBPANEL Total Sq Feet: 0.00 a Plan Check# Plan# Fees Amount payments Amount Paid Battery Storage Device $50.00 Total Fees $110.90 Electrical Permit Issuance Fee $44.35 Cash/Receipt# $110.90 Residential Services up to 400 amps $15.55 Amount Due: Solid Waste Management Fee 2 $1.00 $0.00 Total: $110.90 / /c y" .%rt//( (‘j'L-4 se( Cel'/ e,7 v ' 0.- 11eJ2 CALLS FOR INSPECTION Request for inspection by telephone at 626-574-5450. 7. 5// � ;7241 Leave a message requesting the address,time frame and what inspection item is needed. :',' This permit/plan review expires by time limitation and becomes null and void if the work authorized by the permit is not commenced within 180 days from the date of issuance or if the permit is not obtained within 180 days from the date of plan submittal.This permit expires and becomes null and void if any work authorized by this permit is suspended or abandoned for 180 consecutive days or if no progressive work has been verified by a City of 1 - Arcadia building inspector for a period of 180 consecutive days. 4. Iq ? March 06, 2018 Issued By: Date March 06,2018 Page 1 of 2 of&Re ox.voioN•.6 PERMIT/PLAN REVIEW APPLICATION Development Services Department,240 West Huntington Drive,Post Office Box 60021 of Arcadia, CA 91066-6021, (626) 574-5416,Fax (626) 447-9173 City of Arcadia tfErCENSED CONTRACTOR'S DECLARATION WORKERS'COMPENSATION DECLARATION I hereby affirm under penalty of perjury that I am licensed under provisions of I hereby affirm under penalty of perjury one of the following: Chapter 9(commencing with Section 7000,of Division 3 of the Business and Professions Code,and mylicense is in full force and effect. El have and will maintain a certificate of consent to self-insure for workers' License Class Li'C� Li e Nat k• Exp. Date•'Jocompensation, as provided for by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. Signature of Contractor OWNER-BUILDER DECLARATION have and will maintain workers'compensation insurance,as required by Section ❑ I hereby affirm under penalty of perjury that I am exempt from the Contractors 3700 of the Labor Code,for the performance of the work for which this permit License Law for the following reason(Section 7031.5,Business and Professions is issued.M workers'compensation insurance carrier and policy numbers are: Code.Any city or county which requires a permit to construct,alter,improve, Carrier demolish,or repair any structure,prior to its issuance,also required the applicant2�it'-t �2 for such permit to file a signed statement that he or she is licensed pursuant to the Policy Number provisions of the Contractors License Law(Chapter 9(commencing with Section (This section need not be completed if the permit is for one hundred dollars or less) 7000) of Division 3 of the Business and Professions Code) or that he or she is exempt there from and the basis for the alleged exemption. Any violation of ❑ I certify that in the performance of the work for which this permit is issued,I shall Section 7031.5 by any applicant for a permit subjects the applicant to a civil not employ any person in any manner so as to become subject to the workers' penalty of not more than five hundred dollars($500)): compensation Laws of California,and agree that if I should become subject to the workers'compensation provisions of Section 3700 of the Labor Code,I shall ❑I, as owner of the property, or my employees with wages as their sole forthwith comply with those provisions. compensation,will do the work,and the structure is not intended or offered for '2> '&' 1 '2) sale(Section 7044,Business and Professions Code:The Contractors License Date Signature Law does not apply to an owner of property who builds or improves thereon, or who does such work himself or herself or through his or her own employees,provided that such improvements are not intended or offered for WARNING: Failure to secure Workers'Compensation coverage is unlawful, sale.If,however,the building or improvement is sold within one(1)year of and shall subject an employer to criminal penalties and civil fines up to one completion,the owner-builder will have the burden of proving that he or she hundred thousand dollars($100,000),in addition to the cost of compensation, did not build or improve for the purpose of sale). damages as provided for in Section 3706 of the Labor Code, interest, and attorney's fees. ❑I, as owner of the property, am exclusively contracting with licensed contractors to construct the project(Section 7044,Business and Professions Code:The Contractors License Law does not apply to an owner of property CONSTRUCTION LENDING AGENCY who builds or improves thereon,and who contracts for such projects with a I hereby affirm under penalty of perjury that there is a construction lending agency contractor(s)licensed pursuant to the Contractors License Law). for the performance of the work for which this permit is issued (Section 3097, Civil Code). ❑ I am exempt under Section 7044,Business and Professions Code,for this reason: Lender's Name Date Signature Lender's Address IMPORTANT: APPLICATION IS HEREBY MADE TO THE BUILDING OFFICIAL FOR A PERMIT SUBJECT TO THE CONDITIONrS AND RESTRICTIONS SET FORTH ON THIS APPLICATION AND THE FOLLOWING: F 1. The City's approved plans and permit inspection card must remain on the job site for use by City inspection personnel. 2. Final inspection of the work authorized by this permit is required.A Certificate of Occupancy must be obtained prior to use and occupancy of new buildings and structures. 3. Per South Coast Air Quality Management District(AQMD)regulations,renovation and remodeling work that results in the removal,stripping,or altering of asbestos containing materials requires an asbestos survey and removal prior to disturbing the asbestos. Please contact AQMD at(909) 396-2000 for further information. Name Title PRINT NAME I certify that I have read this application and state that the above information is correct and that I am the owner or duly authorized agent of the owner. I agree to comply with all City ordinances and State Laws relating to building construction. I hereby authorize representatives of the City of Arcadia to enter upon the above-mentioned property for inspection purposes. Signature Date `� . `S FFIDAVIT SELF-CERTIFICATION FOR COMPLIANCE OF SMOKE DETECTORS AND CARBON MONOXIDE ALARMS When the valuation of additions, alterations, or repairs to dwelling units exceeds $1,000.00 smoke detectors shall be installed in each sleeping room, and outside each separate sleeping area in the immediate vicinity of the bedrooms, and on each additional story of the dwelling, including basements and habitable attics as required by Section R314, of the 2013 California Residential Code(CRC). For dwellings or sleeping units containing fuel burning appliances or having attached garages, carbon monoxide detectors shall be installed outside each separate sleeping area in the immediate vicinity of the bedrooms, and on each additional story of the dwelling, including basements as required by Section R315 of the 2013 CRC. All alarms shall comply with requirements for listing and approval by the Office of the State Fire Marshal. 4- Th lr� , eJ7/aa6 Property Address: /� di ��1—�1,.&1N1 �( Building Permit Number: BLD20 - Total#of Bedrooms: Total#of Floors: ( (Including Habitable Basements and Attic Spaces) TOTAL Number of Smoke Alarms in Dwelling Unit: -I TOTAL Number of Carbon Monoxide Alarms in Dwelling Unit: As owner of the above-referenced property, I hereby certify that I have installed the smoke detectors and carbon monoxide detectors in accordance with the manufacturer's instructions and in compliance with the above sections of the California Residential Code, California Building Code and California Health and Safety Code. I declare under penalty of perjury that the foregoing is true and correct, and that this declaration was executed on (Date) 1/z - if Owner's Name (printed/typed): i41Srii JC.J 01 J Signature of Owner: ��^1.6( 1/13.. BSD-111 Form—Afdavit Sell-Certification for Compliance of Smoke and Carbon Monoxide Detectors Updated:06/26/14 tgar RESIDENTIAL SMOKE AND CARBON MONOXIDE ALARM REQUIREMENTS Effective January 1, 2011, all residential permit exceeding$1,000 in valuation shall be required to install smoke and carbon monoxide detectors throughout the residence. Smoke and carbon monoxide detectors shall be installed in accordance with the 2013 California Residential Code (CRC) and shall be verified at the permit final. Smoke alarms shall be tested and maintained in accordance with the manufacturer's instructions. Smoke alarms shall be replaced after 10 years from the date of manufacture marked on the unit, or if the date of manufacture cannot be determined. Smoke alarms shall be installed in the following locations: 1. In each sleeping room. 2. Outside each separate sleeping area in the immediate vicinity of the bedrooms. 3. On each additional story of the dwelling, including basements ad habitable attics but not including crawl spaces and uninhabitable attics. Carbon monoxide alarms shall be installed in the following locations: 1. Outside of each separate dwelling unit sleeping area in the immediate vicinity of the bedroom(s). - -- 2. On every level of a dwelling unit including basements. Code t►blie,ck Smoke&Carbon Monoxide Alarm Locations Smoke alarmI 1 inside each I Smoke&carbon 4 sleeping monoxide alarm `' location outside each I011 . Isleeping location { Smoke alarms at each floor level, habitable attic&basement =2312 Code Cnrr k BSD-11!Form—Affidavit Seii Certification for Compliance of Smoke and Carbon Monoxide Detectors Updated:06/26/14 tgar PROPERTY PLAN Cl.rmal Wh- CONTRACTOR: LA Solar Group /� 16238 B Raymer St., Van Nuys,CA 91406 1 Phone:(818)373-0077 ILIC TYPE:C-46,C-1Q C-39 Pro•ert Line uoee1411s ' � � ' ` 105 - I ` LASOLAR IAra Petrosyan I * r 1 I��� sP I I I111 42 1 I N 30' 8' w 1 E DRIVEWAY 1 s LEGEND ' o It PROPERTY PLAN !ASP El Main Service Panel AC ❑ AC Disconnect .-: '1 ; PV ❑ PV Sub Panel Q T 0 Tesla Sub Palln II =: ' SSP 0 Service Sub Panel I I POOL b I � ril II Orawn ay: I • o I Ara Petrosyan I Ili I ❑ �,,�,. �•rMay Wong N I ,,,III I 1267 Oakglen Ave, Arcadia,CA 91006 af a I I ~� PV SYSTEM S L — r•enenx,2oie 108' —0.5 zlAGTED 'Y Standard Method for Dwelling Service Calculations Worksheet for the EVITP Using the Standard Method complete this worksheet to perform a service load calculation.An example of standard loads is shown below. Owner: May Wong Address: 1267 Oakglen Ave,Arcadia, CA, 91006 Contractor: . LA Solar Group License number: 974115 . - Ara.Petrosyan License class: C10, C-46, C39 Data: 2/27/2018 Step 1: Section 220.12-Lighting load for listed occupancies. Sq.ft X F563711-A 3 VA_ X7;1 R7 VA Step 2 Section 220.52 Small Appliance and Laundry load. 2,397 Sq.ft x3:,1737:70 VA 1744:901 VA 7,Appliances Circuits X 1";600j VA= E1500i SVA `1 ;LaundryCircuit X ` ,. ��,1 50Q ;SVA= X1,500 IVA General Lighting Load = 10191.` VA Step 3:,Table 220.42 Apply demand factors to the general lighting load First 3 000 4 -4 VA at 100% = 3,000. --! VA Remainder at 35% ( ... X 0.35 = ;517 9VA Net Load = [5151.7e,4 VA Step 4: 220.53-Demand Factor-Appliance Loads-Dwelling Units. Disposal = FTO7677.1 VA Dishwasher = 1172000 VA • Compactor = 16:004i ;VA Refrigirator = 1}000 -VA - Tesla 5"800 VA = ..*kftt VA Total = I107;700:;'VA 75%of total;four or more appliances = a:025V VA Step 5: 220.54-Clothes Dryer-The greater of 5 kW or nameplate value. 5,000 kW Electric Dryer • = 5,000 VA Step 6: Table 220.55 Household cooking Equipment Oven = -275-0V7=1 VA Range = 2 000A VA = Yx,:VA Total = x,4,000{,°`i VA r- . Step 7:Article 220.60—Noncoincident Loads Air conditioning 40 A X Ps;m` : - 0 ' V,X. . . , , , 1 , (#) = ,9613.657t.VA : . . . A X ; `. 240. ,.t.. V X `,_ , . . `(#) _ triNalt,VA Electric Heat = ,tom �� ��� AX , >' „G { VX (#) = 0 ` ,VA A X X (#) = A X rffM; RW,gQ; _n,' X (#) = 01 `I VA Largest load • = [91600 ._: VA Step 8: 220.50—25%of largest motor FLA. ,40 .N A X :F. . ', 240'ti: `,? Y,,,,; V X 25% = 2400 VA Remember that although the voltages shown in the tables in Article 430 indicate that motors are rated for 115,230 and 460 Volts, Section 220.5(A) requires nominal voltages of 120, 240 and 480 Volts to be used for load calculations. Step 9:,220.14(A)Other Loads EVSE A X y, ..,450 „ ..4 . AV X 1 (#) = 0 VA Sum of Calculated Loads • _ Lighting, Sm.Appliance, Laundry(Step 3) = 5;617 VA Fastened in Place Appliances(Step 4) = 8niVA Clothes Dryer(Step 5) = VA Cooking Equipment(Step 6) = VA Noncoincedent Heat—A/C(Step 7) = X9600#,"SVA 25% of Largest Motor(Step:8) ••. = 2.4'00',A'VA: Other Loads—(Step 9) . = p14VA' Total Calculated Load = 34 54.2 VA Step 10: Table 310.15(B)(6)—Size the service and conductors. =..3442 VA/240V = 4392,4` Amps Conductor Size CU AL Step 11: Grounding Electrode Conductor—Table 250.66 GEC Size CU AL -