Loading...
HomeMy WebLinkAboutUntitled r .A.. City of Arcadia, CA Permit NO.SOLR-18-0264 ( Development Services Department Permit Type:Solar iiii '' 4 240 West Huntington Drive,Post Office Box 60021 r 1 Arcadia,CA 91066-6021 ; i : IC ( 1 ! r , work Classification:Residential Solar Over 10.KV (626)574-5416 ?":•,' `" Permit Status:Issued k ' ARCADIA 3 Issue Date 03/05/2018: Expiration: 09/01/2018 Addr NO. Dir Prefix Street Name Street Suffix City,State,Zip Parcel Number 246 W Lemon AVE Arcadia,CA 5785020029 „mamaContacts HAROLD HSU Owner PINGO SOLAR Solar Contractor(C-46) 246 W Lemon AVE,Arcadia,CA 8201 ORANGETHORPE AVE D,BUENA PARK,CA 90621 (626)476-7789 (760)888-1228 0 Description:ROOF MOUNTED SOLAR FOR SFR 1/40 . Valuation: $0.00 Tenant b Total Sq Feet: 0.00 Plan Check# Plan# Fees Amount Payments Amount Paid Building Plan Check Fee Residential $50.00 Total Fees $300.91 Electrical Permit Issuance Fee $44.35 Cash/Receipt# $300.91 Fire Plan Check Fee Residential $50.00 Inverters $77.78 Amount Due: $0.00 Panels $77.78 Solid Waste Management Fee 2 $1.00 Total: $300.91 .. COMPLETEO 4.-3u--( r+ CALLS FOR INSPECTION Request for inspection by telephony at 626-574-5450. ' Leave a message requesting the address,time frame and w at inspection r_vL ) item is needed. ...., tfK, This permit/plan review expires by time limitation and becomes null and void if the work authorized by the permit is not commenced within 180 days from the date of issuance or if the permit is not obtained within 180 days from the date of plan submittal.This permit expires and becomes null and void if any work authorized by this permit is suspended or abandoned for 180 consecutive days or if no progressive work has been verified by a City of Arcadia building inspector for a period of 180 consecutive days. March 05, 2018 Issued By: Date March 05,2018 Page 1 of 2 c il i9 PERMIT/PLAN REVIEW APPLICATION iii,' Development Services Department,240 West Huntington Drive,Post Office Box 60021 00,,,,,,....„ � �, Arcadia,CA 91066-6021, (626) 574-5416,Fax (626) 447-9173 '�4u1tY otn City of Arcadia ICENSED CONTRACTOR'S DECLARATION WORKERS'COMPENSATION DECLARATION hereby affirm under penalty of perjury that I am licensed under provisions of I hereby affirm under penalty of perjury one of the following: hapter 9(commencing with Section 7000,of Division 3 of the Business and Professions Code,a my license is in full//f�orce and effect. / // 1:1 I have and will maintain a certificate of consent to self-insure for workers' License Class ( t( License No. IN/Z Exp. Date 3r �I"l compensation, as provided for by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. Signature of Contractor OWNER-BUILDER DECLARATI N F. I have and will maintain workers'compensation insurance,as required by Section I hereby affirm under penalty of perjury that I am exempt from the Contractors ' 3700 of the Labor Code,for the performance of the work for which this permit tiii License Law for the following reason(Section 7031.5,Business and Professions is issued.My workgrs',comus iosu�aflce carrier and policy numbers are: Code.Any city or county which requires a permit to construct,alter,improve, Carrier Q N i demolish,or repair any structure,prior to its issuance,also required the applicant for such permit to file a signed statement that he or she is licensed pursuant to the Policy Number provisions of the Contractors License Law(Chapter 9(commencing with Section (This section need not be completed if the permit is for one hundred dollars or less) 7000)of Division 3 of the Business and Professions Code) or that he or she is exempt there from and the basis for the alleged exemption. Any violation of Li I certify that in the performance of the work for which this permit is issued,I shall Section 7031.5 by any applicant for a pennit subjects the applicant to a civil not employ any person in any manner so as to become subject to the workers' penalty of not more than five hundred dollars($500)): compensation Laws of California,and agree that if I should become subject to the workers'compensation provisions of Section 3700 of the Labor Code,I shall ElI, as owner of the property, or my employees with wages as their sole forthwith comply wi those provisions. compensation,will do the work,and the structure is not intended or offered for / sale(Section 7044,Business and Professions Code:The Contractors License Date ( Signature Law does not apply to an owner of property who builds or improves thereon, or who does such work himself or herself or through his or her own employees,provided that such improvements are not intended or offered for WARNING: Failure to secure Workers'Compensation coverage is unlawful, sale.If,however,the building or improvement is sold within one(1)year of and shall subject an employer to criminal penalties and civil fines up to one completion,the owner-builder will have the burden of proving that he or she hundred thousand dollars($100,000),in addition to the cost of compensation, did not build or improve for the purpose of sale). damages as provided for in Section 3706 of the Labor Code,interest, and attorney's fees. ❑I, as owner of the property, am exclusively contracting with licensed contractors to construct the project(Section 7044, Business and Professions Code:The Contractors License Law does not apply to an owner of property CONSTRUCTION LENDING AGENCY who builds or improves thereon,and who contracts for such projects with a I hereby affirm under penalty of perjury that there is a construction lending agency contractor(s)licensed pursuant to the Contractors License Law). for the performance of the work for which this permit is issued (Section 3097, Civil Code). ❑ I am exempt under Section 7044,Business and Professions Code,for this reason: - Lender's Name Date Signature Lender's Address IMPORTANT: APPLICATION IS HEREBY MADE TO THE BUILDING OFFICIAL FOR A PERMIT SUBJECT TO THE CONDITIONS AND RESTRICTIONS SET FORTH ON THIS APPLICATION AND THE FOLLOWING: 1. The City's approved plans and permit inspection card must remain on the job site for use by City inspection personnel. 2. Final inspection of the work authorized by this permit is required.A Certificate of Occupancy must be obtained prior to use and occupancy of new buildings and structures. 3. Per South Coast Air Quality Management District(AQMD)regulations,renovation and remodeling work that results in the removal,stripping,or altering of asbestos containing materials requires an asbestos survey and removal prior to disturbing the asbestos. Please contact AQMD at(909)396-2000 for further information. e {,�/ Mkt-`h r 11/t 0.-C/k Title d'— PRINT NAME certify that I have read this application and state that the above information is correct and that I am the owner or duly authorized agent of the owner. I agree to comply with all City ordinances and State Laws relating to building construction. I hereby authorize representatives of the City of Arcadia to ente upon the above-mentioned props for inspection purposes. 2 [, ignature Date 2/S/1t Ground Lug Solaredge Reil Power Optimizer P370 unction Box • IIS I _ d zo1__ s 7o Invader =1�---r-I-- IF _-���-ri�� - m 1 I �II� I-1 �4J r ' LI 0 ld I� 1Llj- LI] _] m • w Cable Clip DC Connector C Solar Module (MC4) \ I Module End Clamp 0 mM r=1=_=====11..®®_® =II - °o Module Middle Clamp .1MP • TOP VIEW• C m •Power Optimizer Section Detail Side Door a o GMA�� Scale:Not To ClScale / m u 5 LEGEND JB . ^6 .............. (11)LG Electronics 7. a 0 O Utility Meter • �.� ___ __ Solar Module s' g. 1 € s Q e a ACDS ��/, D LG350Q1C-A5 g b EiZiiA g Existing Main Service Pe" INV_�� • �• D�, 30°Tilt,89"Azimuth , { 1 5,3 a MP noon MainrzaoA Bus ..c - /,� 1 P n 5 II^CDS AC Disconnect 3/4"dia.EMT conduit will run on the roof �.//y I'�i 1 0 7. y Y (3)#10 THWN-2(DC+) Igg~%'/-0 �I��:�1�/� (3)#10 THWN-2(DC-) e,//r PrAh ��t m a I i'' �� ` 0 0 5�/ AZ INV I SaaredgaS1140DAUS (1)#BTHWN-2(Ground) 0• eioJ/�p\ ❑ ❑ D o o l Power Optimizer i.. .�.4..' .1.44-,.1. ❑ ❑ 0 ❑ OPT I solaredge P37o / %i/ ell ❑a WF Roof Access Point 4 i/roA4k •A.L JB Junction Box P%Pr%rrAZ1 i.%E I�%d.�%04. PV2 /nr 4 Generatbn Meter Adapter % Npr^� ��/�E�/'I .4 GMA (23)LG Electronics Solar Module 10/40,/ -A� El DETAIL-C o '�//'is j0 " LG350Q1C-A5 01 oIPA �y:�J+ � // IN k —Module Shinn 30°Tilt,269°Azimuth /P�/7 `� ❑4'•Id.. d m i�/�/�.N/���T�j�.v�..I3-7� ❑ I— I //.;7a%WNW %i ----Conduit will run on the roof ;. I x l*'� %%•�� _ y�/ ~ i'A./'1 z .f , DC 1Mre fr/ .. ' \\� // U I- from Roof N.D. Z 2., ?ttr" Zai 1' -; \`` __�, W > O rG rra 3 0<0 2LU 7 N1P 1 ' 6'-0. f ,-.-,� y .,�m� i o m u_in GMA ACDS INV E Q O r}n '1:10•,. ■ ..°1JU v i V QSideJ 3/4'die.EMT 1- co N o Door m (3)#6 THNM-2(L1,L2,N) in a (1)#g THVJN z(croand) FIMSH GRADE i`t (06)LG Electronics Solar Module N. Dre „ =itamu—• i'A LG350Q1C-A5 BY VT-BHT 30°lilt,179°Azimuth Date 30/16 Sheet Inverter&Main Panel Section Detail Enlarged Roof Layout Plan for PV System Plan North scale As Noted PV4 Scale:1/4"=1' Scale:3/32"=1 Project �' N1\ e '-'-'-'-‘,----, 1) ti"A .,Rt :" AFFI!t E.;VlT SELFmCERTIFICATI'N FOR C - , PLI,;-•;CE OF S' OKE AL ',.R'iS l ND C ,a, BtKI MONOMDE AL, ,F:MS : . Property Address: . :- Permit Number: GV LR-f?..:O).ti Brief Job Description: Pest/ 11-11 I Sb 1 atm Number of smoke alarms installed: Number of carbon monoxide alarms installed: 3 . When alterations, repairs or additions requiring a permit occur,orsleeping rooms are created, Smoke alarms shall be installed in eachsleeping room, and outside each separate sleeping area in the immediate vicinity of the bedrooms, and: on each additional story of the dwelling, including basements and habitable attics as required by Section R314 of the 2016 California Residential Code (CRC) and .California Health and Safety Code Section 13113.7. For dwellings or sleeping units containing fuel burning appliances or having attached garage`s, carbon Monoxide . alarms shall be. installed .outside each separate sleeping area '.inthe immediate vicinity of the bedrooms, and on each additional story of the dwelling, includingbasements as required by Section R31 5. of the of the 2016 .California Residential Code (CRC): Multi-purpose alarms (combination carbon monoxide and smoke alarms) may be used. All alarms shall comply with requirements for listing and approval by the Office oftheStateFire Marshal. http://osfm:fire.ca.qov/licensinglistings/licenselistinq bml searchcotest.php_ As owner of the above referenced property, I hereby certify that the smokealarms and carbon monoxide alarms have been installed in accordance with the manufacturer's instructions and in compliance with the code sections referenced above: I decr:re Under penalty s f perjury that thi- foregoing is true and correct, and that this d‘cl ration was executed on (Date) 1.___14-0,,_ - )-'4=2/6,_--, s t Arcadia, Californi . (Owner's Name(priinted�/typed)°.. Np. -\ 9,v. '\--VLA Signature.of.Owner: V.I�(71r - , wv • This affidavit must be returned to the.City of Arcadia inspector prior to final inspection S ;iC•) E MON OXIIIME A2M_L S Guest Room ® �� , Bathroon �' � 1 Storage }'aamily Room Caaraagc FIRST FLOOR PLAN '® SMOKE AL 'M ® CAR >ON M a NOME AL Mstr 0 , Master Bedroom Dining Room Kitchen Bad' Hall Closet closet -- _ Closet. - = _ Family Room min -- anni amil . Bedroom Bedroom - - — SECOND FLOOR PLAN ®SMOKE AL c:•)\t<<>ON MONOXIDE ALARM tt 3/2/2018 yoursolarptansorn co omit . ► ►��r�04.. ENGINEERING SOLUTIONS FOR ALL YOUR SOLAR NEEDS Structural Calculations for SOLAR POWER SYSTEM CONNECTION CHECK AT: 246 West Lemon Ave. Arcadia,CA 91007 Job: Hsu,Harold Prepared For: Pingo Solar 8201 Orangethorpe Ave. Ste.D Buena Park,CA 90621 (760) 888-1228 Design Criteria 1- Code: CALIFORNIA BLDG CODE 2016/ASCE 7-10 2-Wind: 110 MPH,Exposure:C 3-Wood Species:Douglas Fir Larch(G=0.5) • Notice:Use restrictions of these calculations. The attached Calculations are valid only when bearing original signature hereon,photocopy is void. Contractor/Client to verify existing dimensions/conditions prior to construction. The use of these calculations is solely intended for the above mentioned project. ESS/ON(ckOF TR 0„'49, L NO.C70784 m CL - EXP.06/30/2019 rTI • • v • TF•F CAS\F� . T-844-PV.ELITE info@yoursolarplans.com 3000 E.Birch Street Suite 2011 Brea CA 92821 WIND LOADING ANALYSIS - Roof Components and Cladding Per ASCE 7-10 Code for Bldgs. of Any Height with Gable Roof 0 <=45°or Monoslope Roof 0<=3° Using Part 1 &3:Analytical Procedure (Section 30.4&30.6) Job Name: Hsu, Harold Subject: Job Number: Originator: Checker: Input Data: Wind Speed, V= 110 mph (Wind Map, Figure 26.5-1A-C) 3ldg. Classification = II (Table 1-1 Occupancy Category) Exposure Category= C (Sect. 26.7) B Ridge Height, hr= 34.32 ft. (hr>= he) Eave Height, he= 17.00 ft. (he<= hr) Building Width = 60.00 ft. (Normal to Building Ridge) V Building Length = 65.00 ft. (Parallel to Building Ridge) I L Roof Type= Gable (Gable or Monoslope) I` 'I Topo. Factor, Kzt= 1.00 (Sect. 26.8& Figure 26.8-1) Plan Direct. Factor, Kd = 0.85 (Table 26.6) Enclosed?(Y/N) Y (Sect. 28.6-1 & Figure 26.11-1) Hurricane Region? N 0A Component Name= Fastener (Purlin, Joist, Decking, or Fastener) hr Effective Area,Ae= : `744 ft."2 (Area Tributary to C&C) he Overhangs? (Y/N) N- (if used, overhangs on all sides) Y W L Resulting Parameters and Coefficients: Elevation Roof Angle, 0 = 30.00 deg. Mean Roof Ht., h = 25.00 ft. (h = (hr+he)/2, for roof angle>10 deg.) Roof External Pressure Coefficients, GCp: 3Cp Zone 1-3 Pos. = 0.80 (Fig. 30.4-2A, 30.4-2B, and 30.4-2C) GCp Zone 1 Neg. _ -0.80 (Fig. 30.4-2A, 30.4-2B, and 30.4-2C) GCp Zone 2 Neg. = -1.00 (Fig. 30.4-2A, 30.4-2B, and 30.4-2C) GCp Zone 3 Neg. = -1.00 (Fig. 30.4-2A, 30.4-2B, and 30.4-2C) Positive& Negative Internal Pressure Coefficients, GCpi (Figure 26.11-1): +GCpi Coef. = 0.18 (positive internal pressure) -GCpi Coef. = -0.18 (negative internal pressure) If z<= 15 then: Kz=2.01*(15/zg)^(2/a) , If z> 15 then: Kz=2.01*(z/zg)^(2/a) (Table 30.3-1) a= 9.50 (Table 26.9-1) zg= 900 (Table 26.9-1) Kh = 0.95 (Kh = Kz evaluated at z= h) Velocity Pressure: qz= 0.00256*Kz*Kzt*Kd*VA2 (Sect. 30.3.2, Eq. 30.3-1) qh = 24.89 psf qh =0.00256*Kh*Kzt*Kd*VA2 (qz evaluated at z= h) Design Net External Wind Pressures(Sect. 30.4&30.6): For h <=60 ft.: p=qh*((GCp)-(+/-GCpi)) (psf) For h> 60 ft.: p=q*(GCp)-qi*(+/-GCpi) (psf) where: q =qh for roof qi=qh for roof(conservatively assumed per Sect. 30.6) • Wind Load Tabulation for Roof Components&Cladding Component z Kh qh p= Net Design Pressures(psf) (ft.) (psf) ?one 1,2,3 (+ Zone 1 (-) Zone 2 (-) Zone 3 (-) Fastener 0 0.95 24.89 24.39 -24.39 -29.37 -29.37 15.00 0.95 24.89 24.39 -24.39 -29.37 -29.37 20.00 0.95 24.89 24.39 -24.39 -29.37 -29.37 25.00 0.95 24.89 24.39 -24.39 -29.37 -29.37 30.00 0.95 24.89 24.39 -24.39 -29.37 -29.37 For z= hr: 34.32 0.95 24.89 24.39 -24.39 -29.37 -29.37 For z= he: 17.00 0.95 24.89 24.39 -24.39 -29.37 . -29.37 For z= h: 25.00 0.95 24.89 24.39 -24.39 -29:37 -29.37 Notes: 1. (+) and (-) signs signify wind pressures acting toward &away from respective surfaces. 2. Width of Zone 2 (edge), 'a'= 6.00 ft. 3. Width of Zone 3 (corner), 'a' = 6.00 ft. 4. For monoslope roofs with 0 <= 3 degrees, use Fig. 30.4-2A for'GCp'values with 'qh'. 5. For buildings with h >60'and 0 > 10 degrees, use Fig. 30.6-1 for'GCpi'values with 'qh'. 6. For all buildings with overhangs, use Fig. 30.4-2B for'GCp'values per Sect. 30.10. 7. If a parapet>= 3' in height is provided around perimeter of roof with 0 <= 10 degrees, Zone 3 shall be treated as Zone 2. 8. Per Code Section 30.2.2, the minimum wind load for C&C shall not be less than 16 psf. 9. Reference: a. ASCE 7-10, "Minimum Design Loads for Buildings and Other Structures". b. "Guide to the Use of the Wind Load Provisions of ASCE 7-10" by: Kishor C. Mehta and James M. Delahay(2004). Roof Components and Cladding: 4 hI _0119„,._- ir»---°r- --1 -- 4 _ - a - ofa �� - � ctr _° 'a` .. S'.__ __0.2_ ' . O: O OO O I - (z, 1 1 I1 1 I I I 0 0 v Q n C> Q a ^ IlII ® IQdI ® IQ I I I I 1 1 1 I I I 1 I i I I I 1 I I I 1 1 lr .t T.-0 1.a51-rs 51, 0 <=7 deg. 7 deg. <0 <= 27 deg. 27 deg. <0 <=45 deg. Roof Zones for Buildings with h <=60 ft. (for Gable Roofs<=45°and Monoslope Roofs<=3°) 1 1 -1 i y 1 a 1 a o 1 1 I 1 ROOF PLAN Ci) Roof Zones for Buildings with h > 60 ft. (for Gable Roofs<= 10°and Monoslope Roofs<=3°) Gravity Load Data Panel Data Panel: ' LG350Q1C-A5 Number of Modules: 40 Racking System: Magerack Weight of PV Module 40.8 lbs PV Module Dimensions L= 66.9 in W= 40.0 in Roof Data Roof Material: Tile Roof Dead Load QD= 17 psf PV System Dead Load Qpv= 3 psf Framing Spacing sroof= 24 in Linear Dead Load wD=(QD+Qpv)*woof= 40 plf Lag Screw Check Lumber: DF-L No.2 Uplift Demand Design Wind Pressure p= -29.4 psf(Zone 2) Trib.Depth for Each Rail dpv=L/2= 2.79 ft Trib.Depth for Each Rail bpv=W/2= 1.67 ft Screw Anchor Spacing spy= 4 ft(max.) Uplift Force on Each Screw, Portrait UL=(p+Qpv)*dpv*spy= -294 lbs(Upwards) Uplift Force on Each Screw,Landscape Uw=(p+Qpv)*bpv*spv= -176 lbs(Upwards) Design Uplift Force Puplift=0.6*[Max(UL,Uw)]= -176 lbs(Upwards) Uplift Capacity NDS 2015 Adjustment Factors CD= 1.6 CM= 1 Ct= 1 SG= 0.50 Co,Ceg,Cg,Cd;,Ct„are not appicable Speicfic Gravity of Lumber SG= 0.50 NDS Supplement Table 4a Diameter of Lag Screw D= 5/16 in Withdraw Design/in 1800*SG3/2*D3/"= 266 lbs/in NDS 2015 12.1-1 .. ......._ Depth of Embeddment Ip= 2.50 in Total Nominal Withdrawal Value W=W*1p= 665 lbs Withdrawal Design Vaule W=W*CD*CM*Ct= 1064 lbs NDS 2015 Table 11.3.1 Demand-Capacity Ratio Puplift 1W= 0.17 < 1 [OKAY] • Beam/Top Chord Check Lumber:DF-L No.2 Moment Demand Span: 1 2 3 Orientation j li(ft) pi(lbs) Lenght(ft): 6 6 6 Landscape —1 3.5 -176 2 5.9 -176 3 7.1 -294 Portrait Linear Dead Load wd= 40 plf 4 11.1 -294 Wind Load, Portrait UL_ -294 lbs Portrait 5 12.7 -294 Wind Load, Landscape Uw= -176 lbs 6 16.7 -294 #of Attachment per Rafter NA= 6 WdX2 M(x)=Rt(x—Li)—Pix-1j)— 2 300 — --- -, - F 200 — — — ---Y ---- 100 E 0 • 7= - 00 5I 10.0 : 1 .0 . i 20.0 2 -100 — --- • -200 Length x(ft) . ---- _� ---.—Ma,Moment Dead 178 lb-ft Dead+Wind 186 lb-ft Dead+Snow 178 lb-ft Moment Capacity Framing Member Size 2x4 Lumber Grade: DF-L No.2 CM= 1 C,= 1 Cr= 1.15 CF= 1.5 fb= 900 psi Cf„and C;are not applicablk Breadth b= 1.50 in Depth d= 3.50 in Section Modulus Sx =bd2/6= 3.063 in3 Bending Stress Capacity Fb= CM*Ci*Cr*CF*fb= 1553 psi Table 4.3.1 NDS 2015 Co Fb'=CD*Fb Ma*S. ASD Load Design Bending DCR Dead 0.9 1397 psi 699 psi D 699 psi 0.50 OKAY Dead+Wind 1.6 2484 psi_ 729 psi .6W+.6D 438 psi 0.18 OKAY Dead+Snow 1.15 1785 psi 699 psi D+S 699 psi 0.39 OKAY Deflection Limit E= 1600 ksi I= 5.36 in4 Transient Deflection 0.047 in Transient Deflection Allowed 1541 > 180 [OKAY] Total Deflection 0.111 in Total Deflection Allowed 647 > 120 [OKAY] • SEISMIC WEIGHT COMPARISON/ANALYSIS-(PER CBC 2016 Part 10 Chapter 4 Section 402 PV System Weight Module Model LG350Q1C-A5 Panel Weight Wpanei= 40.79 Number of Panels Npv= 40 lbs Total PV System Weight WpV=Wpanel*Npv= 1631.6 lbs Existing Roof Weight Roof Weight QD= 17.0 psf Building Length Lbulld = 65 ft ' Building Width Wbu;ld = 60 ft Roof Area Abuild= 3900 ft` Building Perimeter Pbuild= 250 ft Wall Height ht= 8 ft Wall weight Qwall= 15 psf Interior wall weight Qint= 10 psf Floor Load Wfloor=Abuild *Qo= 66300 lbs Wall Load Nwall= ht/2 *Qwall* Pbuild+Abulld*Qint/2= 34500 lbs Total Story Weight Wbuild=Moor+Wwall= 100800 lbs Percentage Weight Increa: Wpv/Wbulld= 1.62% < 10% OKAY