Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
Untitled
• 4•_ City of Arcadia, CA Permit NO. ROOF-18-0724 Development Services Department Permit Type:Roof 240 West Huntington Drive,Post Office Box 60021 Arcadia,CA 91066-6021 Work Classification:Residential Reroof (626)574-5416 Permit Status:Issued ARCADIA Issue Date:05/03/2018 I Expiration: 10/30/2018 Addr NO. Dir Prefix Street Name Street Suffix Unit City,State,Zip Parcel Number 1199 Rancho RD Arcadia,CA 5770019013 7111 Contacts PITHAWALLA,BARJOR AND SILLOO TRS Owner PITHAWALLA TRUST 1199 RANCHO RD (626)536-2733 Description:T/0 AND REROOF HOUSE AND GARAGE WITH Valuation: $ 19,000.00 Tenant EAGLELITE,CLASS A DESIGNER SER.,COLOR:WALNUT CREEK BLEND OVERSHEATHI.-NG.'CALCS&HOA ON FILE.VQ Total Sq Feet: 0.00 Plan Check# Plan# _ ("M�/ `4,11111914E, Fees Amount Payments Amount Paid Building Issuing Fee $44.35 Total Fees $438.15 Buil4ing Permit Fees $387.55 Cash/Receipt#REC-001070-2018 $438.15 Solid Waste Management Fee $6.25 Amount Due: $0.00 Total: $438.15 5-61-./ ex, /-6-0(Si /% sz ( ) /c4- ac171 COMPLETED CALLS FOR INSPECTIONS Request for inspection by telephone at 626-574-5450. Leave a message requesting the address,timeframe and what inspection item is needed. This permit/plan review expires by time limitation and becomes null and void if the work authorized by the permit is not commenced within 180 days from the date of issuance or if the permit is not obtained within 180 days from the date of plan submittal.This permit expires and becomes null and void if any work authorized by this permit is suspended or abandoned for 180 consecutive days or if no progressive work has been verified by a City of Arcadia building inspector for a period of 180 consecutive days. May 03, 2018 Issued By: Date May 03,2018 Page 1 of 1 00F0,4,41.4 410 l PERMIT/PLAN REVIEW APPLICATION ir • a r-� Development Services Department,240 West Huntington Drive,Post Office Box 60021 'NeeitY � Arcadia, CA 91066-6021,(626)574-5416,Fax(626)447-9173 City of Arcadia LICENSED CONTRACTOR'S DECLARATION WORKERS'COMPENSATION DECLARATION Q I hereby affirm under penalty of perjury that I am licensed under provisions of I hereby affirm under penalty of perjury one of the following: Chapter 9(commencing with Section 7000,of Division 3 of the Business and Professions Code,and my license is in full force and effect. ❑ I have and will maintain a certificate of consent to self-insure for workers' License Class License No. Exp. Date compensation, as provided for by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. Signature of Contractor OWNER-BUILDER DECLARATION ❑ I have and will maintain workers'compensation insurance,as required by Section ❑ I hereby affirm under penalty of perjury that I am exempt from the Contractors 3700 of the Labor Code,for the performance of the work for which this permit License Law for the following reason(Section 7031.5,Business and Professions is issued.My workers'compensation insurance carrier and policy numbers are: Code.Any city or county which requires a permit to construct,alter,improve, Carrier demolish,or repair any structure,prior to its issuance,also required the applicant for such permit to file a signed statement that he or she is licensed pursuant to the Policy Number provisions of the Contractors License Law(Chapter 9(commencing with Section (This section need not be completed if the permit is for one hundred dollars or less) 7000)of Division 3 of the Business and Professions Code)or that he or she is exempt there from and the basis for the alleged exemption. Any violation of ❑ I certify that in the performance of the work for which this permit is issued,I shall Section 7031.5 by any applicant for a permit subjects the applicant to a civil not employ any person in any manner so as to become subject to the workers' penalty of not more than five hundred dollars($500)): compensation Laws of California,and agree that if I should become subject to the workers'compensation provisions of Sectio 3700 of the Labor Code,I shall ❑I, as owner of the property, or my employees with wages as their sole orthwith comply with those provisions. p� compensation,will do the work,and the structure is not intended or offered for °S 3�t Q' sale(Section 7044,Business and Professions Code:The Contractors License Fate u Signature Law does not apply to an owner of property who builds or improves thereon, or who does such work himself or herself or through his or her own employees,provided that such improvements are not intended or offered for WARNING: Failure to secure Workers'Compensation coverage is unlawful, sale.If,however,the building or improvement is sold within one(1)year of and shall subject an employer to criminal penalties and civil fines up to one completion,the owner-builder will have the burden of proving that he or she hundred thousand dollars($100,000),in addition to the cost of compensation, did not build or improve for the purpose of sale). damages as provided for in Section 3706 of the Labor Code, interest, and attorney's fees. ❑I, as owner of the property, am exclusively contracting with licensed contractors to construct the project(Section 7044,Business and Professions Code:The Contractors License Law does not apply to an owner of property CONSTRUCTION LENDING AGENCY who builds or improves thereon,and who contracts for such projects with a I hereby affirm under penalty of perjury that there is a construction lending agency contractor(s)licensed pursuant to the Contractors License Law). for the performance of the work for which this permit is issued (Section 3097, Civil Code). 0 I am exempt under Section 7044,Business and Professions Code,for this reason: Lender's Name 05-0S-ft ate Si8n azure AULender's Address IMPORTANT: APPLICATION IS HEREBY MADE TO THE BUILDING OFFICIAL FOR A PERMIT SUBJECT TO THE CONDITIONS AND RESTRICTIONS SET FORTH ON THIS APPLICATION AND THE FOLLOWING: 1. The City's approved plans and permit inspection card must remain on the job site for use by City inspection personnel. 2. Final inspection of the work authorized by this permit is required.A Certificate of Occupancy must be obtained prior to use and occupancy of new buildings and structures. 3. Per South Coast Air Quality Management District(AQMD)regulations,renovation and remodeling work that results in the removal,stripping,or altering of asbestos containing materials requires an asbestos survey and removal prior to disturbing the asbestos. Please contact AQMD at(909)396-2000 for further/�Information. .\ Qfaro iL sre1rrys1...1OrL V A Title PRINT NAME I certify that I have read this application and state that the above information is correct and that I am the owner or duly authorized agent of the owner. I agree to comply with all City ordinances and State Laws relating to building construction. I hereby authorize representatives of the City of Arcadia to enter upon bove-mentioned property for inspection purposes. 0 p nature Date 3� O , \ FILE NO. DATE FILED APPLICATION FOR HOMEOWNER ASSOCIATION ARCHITECTURAL DESIGN REVIEW (SHORT REVIEW PROCEDURE) PROJECT ADDRESS: \\0q 9PnACHO 9,o M.' LC-P) PI) 1 q $ . PS' \b0 PROPERTY OWNER'S NAME• f3IS,) Z'. lT- 'tNAW Eau.'P.) --- ADDRESS(IF DIFFERENT): --— — TELEPHONE NO: 6%6-536- *1,3 E-MAIL ADDRESS. 0.W X 0 Q____hCft en 1 Ccriv) APPLICANT NAME (IF DIFFERENT). ADDRESS: TELEPHONE NO.: E-MAIL ADDRESS: DESCRIPTION OF PROJECT(Check applicable): ❑ Single-story remodel (includes window replacement)and/or addition(s) ❑ Detached accessory structure(s) and/or Accessory Dwelling Units- new, additions to, and/or remodels ❑ Fences and/or walls in and/or facing (i.e., visible from) front and street side yards ❑ Hardscape, landscaping and structural elements in front and street side yards, including without limitation, swimming pools, spas, fountains and other water features ❑ Fences, lights, and other features related to tennis courts, sports courts or other significant paved features ❑ Mechanical equipment TIA Roofing-_ --t ACTION & FINDINGS: >ir Approved-The project is consistent with all applicable guidelines 14/0q4Nt["r < 63LElA / Li Conditionally Approved -With the following conditions,the project will be consistent with all applicable guidelines --- LI Denied-The project is not consistent with the following guideline(s) ///� V ��% By / �; i ARB Chairperson Date -37/;2-..7f: nC'S/c�iG,_ 7' 5.'%*) Av/T/a Q K5� '?Ad 4 6/17 . 0.4\ ENGINEERING 2207 Merced Ave Tel:(213)725-8011 South El Monte,CA 91733 Fax: (213)769-8656 Client: Owner Builder May 1,2018 1199 Rancho Rd Arcadia,CA 91006 626-536-2733 Subject:Remove existing Calshake and replace with light weight Eagle concrete tile, Project Address: Pithawal Family Dwelling 1199 Rancho Rd Arcadia,CA 91006 626-536-2733 Pursuant to your request,we have reviewed the roof framing of the structure at the above address for structural adequacy for accommodating the proposed new roofing material.The house is conventionally framed.The existing roof is comprised of: Use of Building = S.F.D. Number of Stories= Single Building Area = 6,125 S.F. Year Built = 1940 Construction Type= Type V-B Roof pitch of 5:12,and appear to be in sound condition. �O ESSION, Asphalt Shingles roofing materials, Q 1"x6"Solid sheathing, _ 2"x6"Roof Rafters @ 16"O.C.max span 13'-0", e,/��ii 2"x6"Roof Rafters @ 16"O.C.max span 14'-0", z*eamis . .. 2"x8"Hip/Valley beams max span 12'-0", • New proposed roofmg materials: Eagle Capistrano standard weight concrete tile @ 7.2 psf.ESR#1900 1-30#ASTM Felt Paper roofing underlayment Couclusion, , OpA, FGA 01�\P Calculations show that existing roof members are adequate to support the desired new Eagle concrete tile, It is therefore;our opinion that re-roofmg with concrete tile will not compromise the structural integrity of the roof system at the named project address. The determination of the roof's structural integrity is based on visual observation and known mechanical properties of wood.After re-roofing,a small amount of deflection in the rafters may be observed.This condition is cosmetic only and should not affect the structural integrity of the roof framing. Based on our review of the structure we believe that the structure has adequate amount of braced walls, sufficient to resist lateral loads. It is our opinion that the structure is adequate to sustain the new seismic loads generated due to the proposed concrete tile. Instructions to Roofer: 1. Remove and Replace any damaged roof sheathing prior to installation of new felt paper. 2.Provide ST22,or equivalent,metal straps over ridge @16"O.C.,attach per detail Sheet SD-1. , . ,_1, 23 0' , a ti a `'o. so. O 5 V ( RF.p TR X RF? FTR HIP \/ _ a • rii c a X \\/7.t. -1,,, O ro+ \ Z o � O � 1( RF.RF TR x RF:RFTR O 9'\\I, o p. r.mC) ' •o b % \ i.� a 3. r o a a N a a o Z +-- V X o L' a 'L„ a.x q .c +.o S m + A 9 V 1 37,-0" J, Ia E E e SINGLE FAMILY RESIDENCE EXISTING DARY ENGINEERING "-=' . n 1199 RANCHO ROAD _ 2207 MERGED AVENUE —Z� Trio- s 7 5 ARCADIA, CA 91006 ROOF FRAMING SOUTH EL MONTES CA 91733 ' . ° 626-536-2733TEL/FAX. 213-725-8011/213-769-8656 ,' P_A N p�ARYENGINFERINGeYAy(iQ EpY R num a 111 2X8 RIDGE BRD . - 2X6 CONT . PURLIN J, TYPICAL WHERE OCCURS N ao Q Q O U H e, 1X6 SOLID SHTN ' G— —2X6 R . R . @16 "O. C . = W=og TYPICAL = .. . - TYPICAL w W O W ti �w - ao� \\ w U Z x r m—c w w�o O N 2 0 2X4@4 / 0. C . 2X6C . JST@1 6 "0. C . WHERE OCCURS TYPICAL - `" >- u-) F— v� cc N- cD W D O � O O VARIES 12 ' -O "-- 30 ' -0 " S-e 2 U Q U N ti Z - 1 Q W Cr — - -- O ✓ Q. Q I TYPICAL SECTION CV LCD N — Q iD OTE .n/H NOT TO SCALE "" E1 A-2 Criteria Dary Engineering 2207 Merced Ave South El Monte,CA 91733 Job Name: 1199 Rancho Rd.Arcadia Ph:(213)725-8011 Job Numb: 428-18 Fax:(213)769-8656 Date: April 30,2018 DESIGN CRITERIA I ROOF LOADS I i ROOF VAULTED LOADS I ( CEILING LOADS I I FLOOR LOADS I Roofing = 7.2 psf Roofing = 7.2 psf Flooring = 0.0 psf Sheating = 1.8,psf Sheathing = 1.8 psf Sheathing = 0.0 psf R.Rafters = 2.3 psf R.Rafters = 2.3 psf Joist = 1.5 psf Joist = 0.0 psf Ceiling = 0.0 psf Ceiling = 2.5 psf Ceiling = 2.5 psf Ceiling = 0.0 psf 1x6 Skip Shtn'g= 0.0 psf 1x6 Skip shtn= 0.0 psf Sprinkler = 0.0 psf Sprinkler = 0.0 psf Mechanical = 0.0 psf Mechanical = 0.0 psf Mechanical = 0.5 psf Mechanical - 0.0 psf Misc. = 0.3 psf Misc. 0.0 Misc. = 0.0 L.W.Concret = 0.0 Insulation = 0.5 psf Insulation = 0.5 psf Insulation = 0.5 psf Insulation = 0.0 psf Total DL = 12.0 psf Total DL = 14.2 psf Total DL = 5.0 psf Total DL 0.0 psf DL = 12.0 psf DL = 14.0 psf DL = 5.0 psf DL = 0.0 psf LL = 20.0 psf LL = 20.0 psf LL = 10.0 psf LL = 0.0 psf Deck LL = 0.0 psf Deck DL = 0.0 psf Partitions DL = 0.0 psf WOOD STRESSES: Douglas Fir Larch(North)Table 4A and 4D-(UBC 1977-1997) Lumber Size Fb(psi) Tension Parall Horizontal Comp/Perpend. Comp/Parall Modulus Type Single Ft(psi) Fv(psi) Fcp(psi) Fcp(psi) E(psi) Sel Struc. 2"to 4" 1800 1000 95 730 1450 1.8E06 No 1 thick 1800 675 95 625 1250 1.8E06 No.2 5"and 1450 450 95 625 1000 1.7E06 Studs wider 800 600 95 625 600 1.5E06 Select Struct Beams 1600 950 170 625 1100 1.6E06 Not and 1550 675 170 625 925 1.6E06 No 2 Stringers 875 425 170 625 600 1.3E06 Select Struct 1500 1000 170 625 1150 1.6E06 No 1 Posts 1200 825 170 625 1000 1.6E06 No 2 700 475 170 625 475 1.3E06 Glue Lams, Alls 2400 165 560 1650 1.8E06 24F-V8,DF/DF Struct. Steel: A-36, Fb=0.6Fy, Fv=0.4Fy, E=29E06 psi Welding: Use AWS-E70XX, per American Welding Society Standards, (1/2 stresses for Non Continuous Inspection) Concrete: Continuous Ftgs fc @ 28 days = 2500 psi Isolated Pads fc @ 28 days = 2500 psi Walls fc @ 28 days = 2500 psi Piers or Col's fc @ 28 days = 2500 psi Reinforcement: For#4 and smaller bars = 40000 psi For#5 and larger bars = 60000 psi Masonry: Hollow Concrete Masonry Units ASTM C-90 and UBC Standards Type N Units,Type S mortar,2000 psi grout fm=1500 psi(solid grouted), Fm=250psi Soil Bearing: Minimum Allowable soil bearing Value=1500 psf per Table 1804.2 IBC 2015/CBC 2016 Or see Soil Report recommendations for soil bearing capacity on compacted cerified fill. CODES: International Building Code(IBC)2015,CBC 2016 American Institute of Steel Construction(AISC) American Concrete Institute(ACI) National Design Specifications(NDS)2007 Edition National Design Specifications(NDS)2007 Supplement Page 2 • • • • • • tr i K . ._ _ • • • i,. �.. . . • _• I. . ' DARY ENGINEERING Project Title: 1199 Rancho Rd 2207 Merced Avenue Engineer: D.Yassin Project ID: 428-18 South El Monte,CA 91733 Project Descr: Re roofing with standard wt concrete tile 213-725-8011 213-291-0778 Daryengineering@yahoo.com primed: 1 baY 2018.5:31PM File=C:IUsenADIAAYA•11D000ME-11ENERCA-111199RA-1.EC6 Multiple Simple Beam ENERCALC,INC.1983-2014,Build:6.14.7.31,Ver.6.14.7.31 Lic.#:KW-06008304 Licensee: DARY ENGINEERING Description : Roof framing members Wood Beam Design : Rf. Rftrs Calculations per 2015 NDS,IBC 2015,CBC 2016,ASCE 7-10 BEAM Size: 2.0 X 6.0,Sawn, Fully Braced Using Allowable Stress Design with IBC 2012 Load Combinations,Major Axis Bending Wood Species: Douglas Fir-Larch Wood Grade: No.1 Fb-Tension 1,350.0 psi Fc-PAI 925.0 psi Fv 170.0 psi Ebend-xx 1,600.0 ksi Density 32.210 pcf Fb-Compr 1,350.0 psi Fc-Perp 625.0 psi Ft 675.0 psi Eminbend-xx 580.0 ksi Applied Loads Unif Load: D=0.0150, Lr=0.020 k/ft,Trib=1.330 ft Design Summary Max fb/Fb Ratio = 0.565; 1 D(0.01995)Lr(0.02660) fb:Actual: 1,140.48 psi at 7.000 ft in Span#1 t r-_-_ } 4 } Fb:Allowable: 2,018.25 psi ____-__ _ l Load Comb: +D+Lr+H Max fv/FvRatio= 0.224: 1 14.0 It 2.0x6.0 fv:Actual: 38.02 psi at 13.533 ft in Span#1 Fv:Allowable: 170.00 psi Load Comb: +D+Lr+H Max Deflections Max Reactions (k) Q I. Lt 5 W E B Downward L+Lr+S 0.401 in Downward Total 0.702 in Left Support 0.14 0.19 Upward L+Lr+S 0.000 in Upward Total 0.000 in Right Support 0.14 0.19 Live Load Defl Ratio 418 >240 Total Deft Ratio 239>180 Wood Beam Design : HipNall Beams Calculations per 2015 NDS,IBC 2015,CBC 2016,ASCE 7-10 BEAM Size: 2.0 X 8.0,Sawn, Fully Braced Using Allowable Stress Design with IBC 2012 Load Combinations,Major Axis Bending Wood Species: Douglas Fir-Larch Wood Grade: No.1 Fb-Tension 1,350.0 psi Fc-Pill 925.0 psi Fv 170.0 psi Ebend-xx 1,600.0 ksi Density 32.210 pcf Fb-Compr 1,350.0 psi Fc-Perp 625.0 psi Ft 675.0 psi Eminbend-xx 580.0 ksi Applied Loads Unif Load: D=0.0->0.120, Lr=0.0->0.160 klft,0.0 to 12.0 ft Design Summary Max fb/Fb Ratio = 0.781- 1 ' ' 1 1 ,1 ,' 1 1 .1 lb:Actual: 1,454.92 psi at 6.920 ft in Span#1 '---- Fb:Allowable: 1,863.00 psi __. _._ _I Load Comb: +D+Lr+H . Max fv/FvRatio= 0.521: 1 N:Actual: 88.65 psi at 11.360 ft in Span#1 12.017, 2.0 x 8.0 Fv:Allowable: 170.00 psi Load Comb: +D+Lr+H Max Deitections Max Reactions (k) Q L Lt S V E B Downward L+Lr+S 0.275 in Downward Total 0.482 in Left Support 0.24 0.32 Upward L+Lr+S 0.000 in Upward Total 0.000 in Right Support 0.48 0.64 Live Load Defl Ratio 523 >240 Total Defl Ratio 298 >180 Wood Beam Design : 2x6 Contin. Purlins Calculations per 2015 NDS,IBC 2015,CBC 2016,ASCE 7-10 BEAM Size: 2.0 X 6.0,Sawn, Fully Braced Using Allowable Stress Design with IBC 2012 Load Combinations,Major Axis Bending Wood Species: Douglas Fir-Larch Wood Grade: No.1 Fb-Tension 1,350.0 psi Fc-PAI 925.0 psi Fv 170.0 psi Ebend-xx 1,600.0 ksi Density 32.210 pcf Fb-Compr 1,350.0 psi Fc-Perp 625.0 psi Ft 675.0 psi Eminbend-xx 580.0 ksi Applied Loads Unif Load: D=0.0150, Lr=0.020 k/ft,Tnb=7.0 ft Design Summary D(0.1050 La0,140) Max fb/Fb Ratio = 0.628. 1 - ' fb:Actual: 1,102.50 psi at 3.000 ft in Span#1 ` Fb:Allowable: 1,755.00 psi - - Load Comb: +D+Lr+H Max fv/FvRatio= 0.454: 1 N:Actual: 77.18 psi at 5.520 ft in Span#1 Fv:Allowable: 170.00 psi 6.011, 2 0 X8 0 , Load Comb: +D+Lr+H Max Deflections Max Reactions (k) Q L Li a 1t ti ti Downward L+Lr+S 0.071 in Downward Total 0.125 in Left Support 0.32 0.42 Upward L+Lr+S 0.000 in Upward Total 0.000 in Right Support 0.32 0.42 Live Load Dell Ratio 1010 >240 Total Defl Ratio 577 >180 r a EQ . EQ . SIMPSON CS16 / / / SIMPSON LSTA24 16 " 16 " SIMPSON MSTA24 ALSO MAY BE USED 6 -8D EACH SIDE SIMP . ST22 STRAP MINIMUM @16 "0 . C . 0.0 W Z M ESR#2105 Woo_ Z W S N /1 Wzwwx 3 a S 4 N ¢00_1 Q N O W O N O VI�- EXIST . 2X R . R . Y \ EXIST . 2X R . R . PER PLAN V @16 "0 . C . 7777/77 A R . BOARD W U 2 W 0 N iD WOO 2 Q O O ,.m J -OLINn XMON N Q U N TYPICAL STRAP DFTAIL w._, Om<1 Z m U tD 2 N . T . SCALE "�"° OAR S/yam, SCALE N.T.S CRAM ..r. JOB NNIS SHEET • SD-1 Designer Series Estate 88.5 Tiles per 100 sq ft with 3"headlap 720 EF rox ins \ \ ght fiel #— ‘1\1141111.,r ------\17" _______------- 1 7' \ ` \ 1 07/0/101"' _--_,7. \ \ r-- - A''''' /1511\\---I � :12 y3' ��\..�11 3/3'�' \ 5 7/B-./A .y- Ir _r -t„ r r LHE 8704 Lehigh Blend-Natural Gray,Light Gray,Charcoal Blend - • ® Ref:.15 Emi:.94 SRI:15 A.SRI:16 CRRC:0918-0046 NI • .. , ' ft. . , 1111 . .1 , ,,-... j •: , aka- iv______ , 0 Estate . LHE 8704 Lehigh Blend v; s LHE 8715 Roanoke Blend-Light Gray,Dark Gray,Gold,Taupe Blend ® Ref:.17 Emi:.89 SRI:15 A.SRI:16 CRRC:0918-0081 ill NEW AU". A . . . ._ L, • LHE 8773 Walnut Creek Blend-Gray,Tan,Orange,Dark Brown BlendLHE 9700 Bennington Blend-Green,Gray,Light Green,Charcoal Blend ® Ref:.20 Emi:.94 SRI:21 &SRI:23 CRRC:0918-0037 ® MI Ref:.15 Emi:.92 SRI:14 A.SRI:18 CRRC:0918-0032 iii • it1 ICC EVALUATION Most Widely Accepted and Trusted S SERVICE ICC-ES Report ESR-1900 ICC-ES I (800) 423-6587 I (562) 699-0543 I www.icc-es.org Reissued 03/2016 This report is subject to renewal 03/2017. DIVISION: 07 00 00—THERMAL AND MOISTURE PROTECTION SECTION: 07 32 16—CONCRETE ROOF TILES REPORT HOLDER: EAGLE ROOFING PRODUCTS, A DIVISION OF BURLINGAME INDUSTRIES, INC. 3546 NORTH RIVERSIDE AVENUE RIALTO, CALIFORNIA 92377 EVALUATION SUBJECT: EAGLE® AND EAGLELITE® INTERLOCKING CONCRETE ROOFING TILES: CAPISTRANO, MALIBU, BEL AIR, ESTATE, DOUBLE EAGLE BEL AIR, PONDEROSA, DOUBLE EAGLE PONDEROSA, GOLDEN EAGLE, ARTISAN AND TAPERED ARTISAN ICC ICC ICC ES PMG . LISTED Look for the trusted marks of Conformity! "2014 Recipient of Prestigious Western States Seismic Policy CouncilINZ (WSSPC)Award in Excellence" A Subsidiary of cumcouecii ICC-ES Evaluation Reports are not to be construed as representing aesthetics or any other attributes not "`cam" specifically addressed, nor are they to be construed as an endorsement of the subject of the report or a ANSI6 recommendation for its use. There is no warranty by ICC Evaluation Service, LLC, express or implied, as MIN Mail/wp ps to any finding or other matter in this report, or as to any product covered by the report. ►cefficommi AccAON CCM Copyright© 2016 ICC Evaluation Service, LLC.All rights reserved. ES ICC EVALUATION SERVICE Most Widely Accepted and Trusted ICC-ES Evaluation Report ESR-1900 Reissued March 2016 This report is subject to renewal March 2017. www.icc-es.orq I (800)423-6587 I (562) 699-0543 A Subsidiary of the International Code Council® DIVISION:07 00 00—THERMAL AND MOISTURE and proprietary additives and comply with ASTM C1492. PROTECTION Mineral coloring oxides are mixed with the portland cement Section: 07 32 16—Concrete Roof Tiles and water for through-color or for surface application following extrusion. All roof tiles are cured to reach REPORT HOLDER: required strength before shipment. Tiles are manufactured with 3/4-inch-wide (19 mm) interlocking sidelaps designed EAGLE ROOFING PRODUCTS,A DIVISION OF to resist surface water penetration and maintain proper BURLINGAME INDUSTRIES, INC. alignment. All tiles have protruding head lugs on the 3546 NORTH RIVERSIDE AVENUE underside, which provide for mechanical attachment over RIALTO,CALIFORNIA 92377 battens, or provide a stable foundation for nail attachment (909)822-6000 to solid decking. Two nail holes are provided for low profile www.eauleroofing.com tiles. Three nail holes are provided for medium and high profile tiles. EVALUATION SUBJECT: Product designations, dimensions and installed dry EAGLE®AND EAGLELITE®INTERLOCKING CONCRETE weights are indicated in Table 1. Roof tile profiles are ROOFING TILES: CAPISTRANO,MALIBU, BEL AIR illustrated in Figure 1. ESTATE,DOUBLE EAGLE BEL AIR, PONDEROSA, The attributes of the Eagle®and Eaglelite®roof tiles have DOUBLE EAGLE PONDEROSA, GOLDEN EAGLE, been verified as conforming to the provisions of CALGreen ARTISAN AND TAPERED ARTISAN Section A5.406.1.2 for reduced maintenance. Note that decisions on compliance for those areas rest with the user 1.0 EVALUATION SCOPE of this report. The user is advised of the project-specific 1.1 Compliance with the following codes: provisions that may be contingent upon meeting specific conditions, and the verification of those conditions is • 2015,2012 and 2009 International Building Code®(IBC) outside the scope of this report.These codes or standards • 2015, 2012 and 2009 International Residential Code® often provide supplemental information as guidance. (IRC) 3.2 Eaglelite®Tiles: • 2013 Abu Dhabi International Building Code(ADIBC)t Eaglelite®tiles are produced in the same size, manner and 1The ADIBC is based on the 2009 BC.2009 IBC code sections referenced shapes as the conventional-weight Eagle® tiles described in this report are the same sections in the ADIBC. in Section 3.1, except for substitution of lightweight Properties evaluated: aggregates and additives for sand. Product designations, • Fire classification dimensions and installed dry weights are indicated in Table 1.Roof tile profiles are illustrated in Figure 1. • Weather resistance 4.0 INSTALLATION • Wind-uplift resistance 1.2 Evaluation to the following green code: 4.1 General: • 2013 California Green Building Standards Code Installation of the Eagle®and Eaglelite®concrete roof tiles (CALGreen),Title 24, Part 11 must be in accordance with the Concrete and Clay Roof Tile Installation Manual for Moderate Climate Regions, Attributes verified: dated March 2010, published by the Tile Roofing Institute • See Section 3.1 and Western States Roofing Contractors Association 2.0 USES (hereinafter referred to as the TRI/WSRCA installation manual), except as otherwise noted in this report. This The Eagle®and Eaglelite®concrete roof tiles installed over report and the TRI/WSRCA installation manual must be solid sheathing are used as Class A roof coverings in available at the jobsite at all times during installation. The accordance with IBC Section 1505.2 and IRC Section minimum roof slope on which the roof tiles are installed R902.1. must be 21/2:12 (20.83%). Care must be taken during field 3.0 DESCRIPTION installation to ensure that horizontal joints are kept parallel ® to the eave and vertical joints are at right angles to the 3.1 Eagle Tiles: eave in order to ensure uniform contact between the tiles These roof tiles are interlocking extruded concrete roof and proper fit. All cracked and broken roof tiles must be tiles composed of Type II portland cement, washed sand, replaced. Underlayment must comply with and be installed ICC-ES Evaluation Reports are not to be construed as representing aesthetics or any other attributes not specifically addressed,nor are they to be construedIII ANSIas an endorsement of the subject of the report or a recommendation for its use.There is no warranty by ICC Evaluation Service,LLC,express or implied,as to any finding or other matter in this report,or as to any product covered by the report. sur:=. Copyright©2016 ICC Evaluation Service,LLC.All rights reserved. Page 1 of 4 • ESR-1900 I Most Widely Accepted and Trusted Page 2 of 4 in accordance with IBC Section 1507.3.3 or IRC Section accordance with the requirements of the applicable code. R905.3.3, as applicable. The roof classification is as noted in Section 4.3. 4.2 Adhesive Set Systems: When reroofing wood shake roofs, existing shakes must The roof tiles may be installed with roof tile adhesives that be removed and solid decking and tile must be installed, are recognized in a current ICC-ES evaluation report for as with new construction. When installation is over use in concrete roofing tile applications. Installation of tiles existing spaced sheathing boards, underlayment using these adhesive set systems must be in accordance complying with the requirements of the applicable code or with the adhesive manufacturer's ICC ES evaluation an underlayment recognized specifically for this type of use report. in an ICC-ES evaluation report, installed with or without battens, may be used. One layer of ASTM D226, Type II 4.3 Fire Classification: (No. 30)felt or approved equivalent underlayment must be installed on the roof prior to application of tile. Details not When installed in accordance with this report, the Eagle® covered under this section are identical to those described and Eaglelite® concrete roof tiles are Class A roof coverings in accordance with IBC Section 1505.2 and IRC in Section 4.1. Section R902.1.When roof tiles are installed with a roof tile 5.0 CONDITIONS OF USE adhesive, installation must be in accordance with The Eagle® and Eaglelite®concrete roof tiles described in ESR-1709. this report comply with, or are suitable alternatives to what 4.4 Wind Resistance: is specified in, those codes listed in Section 1.0 of this 4.4.1 2015 IBC, 2015 IRC and 2012 IBC: For ultimate report,subject to the following conditions: design wind speeds (Vu,t) of 130 mph (209 km/h) or less 5.1 The roof tiles must be installed in accordance with this and mean roof heights of 60 feet (18.3 m) or less for the report, the applicable code and the TRI/WSRCA IBC or 40 feet (12.2 m) or less for the IRC, tiles must be installation manual, dated March 2010. In case of a installed in accordance with the prescriptive parameters conflict between the installation manual and this of IBC Table 1507.3.7 or IRC Section R905.3.7, as report,this report governs. applicable. 5.2 The roof decking and roof framing system must be 4.4.2 2012 IRC: For basic wind speeds of 100 mph designed for the appropriate loads determined in (161 km/h) or less and mean roof heights of 40 feet accordance with the applicable code. (12.2 m)or less, tiles must be installed in accordance with 5.3 The tiles are limited to installation on roofs with a the prescriptive parameters of Section R905.3.7 of slope of 60 degrees or less from horizontal. the IRC. 4.4.3 2009 IBC and IRC: For basic wind speeds Exception: Installation on roof slopes exceeding 60 (3-second gust) of 100 mph (161 (kmh) or less and mean degrees from the horizontal require an approved wind roof heights of 60 feet(18 288 mm) or less for the IBC or clip on the bottom edge of each tile in addition to two 40 feet (12 192 mm) or less for the IRC, tiles must be fasteners per tile. installed in accordance with the prescriptive parameters of 5.4 The Eagle®and Eaglelite®concrete tiles are produced Table 1507.3.7 of the IBC or Section R905.3.7 of the IRC, at the manufacturing facilities specified in Table 1 as applicable. For applications beyond these prescriptive under a quality control program with inspections by parameters, the tiles and the fastening systems must ICC-ES. be designed to withstand the aerodynamic wind uplift 6.0 EVIDENCE SUBMITTED moment in accordance with the section on Design Considerations for High Wind Applications in Appendix B Data in accordance with the ICC-ES Acceptance Criteria of the TRI/WSRCA installation manual. The generic for Clay and Concrete Roof Tiles (AC180), dated February required aerodynamic uplift moment, determined in 2012(Editorially revised April 2015). accordance with Tables 5A through 6D of the TRI/WSRCA 7.0 IDENTIFICATION installation manual, must be multiplied by the tile factor ratio in Table 2 of this report to obtain the required Each Eagle field tile is imprinted with the EAGLE logo aerodynamic uplift moment for the specific roof tile being (see Figure 2). Tiles produced at the Sumterville, Florida, installed. The allowable aerodynamic uplift moment for the plant have the EAGLE logo and"FLORIDA"(see Figure 3) roof tile fastening system selected from Table 7A of the imprinted on each field tile. Each Eaglelite tile is identified TRI/WSRCA installation manual, must be equal to or by the product name "Eaglelite" on a tag and a light- greater than the required aerodynamic uplift moment for colored strip across the headlap area. Each shipping pallet the specific roof tile being installed. must have a label bearing the Eagle Roofing Products 4.5 Reroofing: name; the tile designation; manufacturing location and address; color; quantity of tiles per pallet; production date; Eagle® and Eaglelite®tiles may be installed over existing installed weight; and the evaluation report number asphalt shingles, provided the requirements set forth in (ESR-1900). IBC Section 1510 or IRC Section R907, as applicable, are met. Damaged or rusted flashing must be replaced. Existing framing must be adequate for the additional load. Structural data verifying adequacy must be submitted to the code official. The existing roof must be inspected in ESR-1900 I Most Widely Accepted and Trusted Page 3 of 4 TABLE 1—TILE DIMENSIONS,INSTALLED WEIGHTS AND MANUFACTURING FACILITIES DIMENSIONS` INSTALLED DRY WEIGHT' TILE DESIGNATION PROFILE (inch) (psf) MANUFACTURING LENGTH WIDTH Eagle Eaglelite1D FACILITY 8.8 -- Sumterville,Florida Capistrano High 9.0 5.7 Rialto&Stockton,California 9.0 -- Phoenix,Arizona 7.7 — Sumterville,Florida Malibu Medium 17 123/8 9.03 5.5 Rialto&Stockton,California 9.03 — Phoenix,Arizona Bel Air,Estate,Double Eagle Bel Air, __ Phoenix,Arizona& Ponderosa,Double Eagle Ponderosa, Flat(Low) 9.7 Sumterville,Florida Golden Eagle,Artisan and Tapered Artisan 9.7 7.2 Rialto&Stockton,California For SI: 1 inch=25.4 mm, 1 psf=4.88 kg/m2. 'Installed dry weight is based on a 3-inch headlap. 2AII dimensions are nominal. TABLE 2-TILE FACTORS AND TILE FACTOR RATIOS TILE DISIGNATION TILE(Fft3)TOR TILE FACTOR RATIO' Capistrano 1.463 1.040 Malibu 1.486 1.056 Bel Air,Estate,Double Eagle Bel Air, Ponderosa,Double Eagle Ponderosa,Golden 1.468 1.043 Eagle,Artisan,Tapered Artisan For SI: 1 inch=25.4 mm 'Tile factor ratio=Tile factor/Base tile factor of 1.407 ft3.See Section 4.4.3 of this report and Appendix B of the TRI/WSRCA installation manual for additional details. • ESR-1900 I Most Widely Accepted and Trusted Page 4 of 4 -\\\ -\ 17' lik NigiS l• 19• c11111444 ID 123/11------4- \yJ12970'�f• \�f- 8.X1 Jr\�_____-10•- Capistrano Tile Malibu Tile Capistrano/Malibu Trim Tile io• 1\ Alhbb.. r n 17 \ •\\\ ,N' 11d• /////46la , • j.A(100111 ---\�_12 9re• • \r-,1299•-• - `\...._______12 9/0•'---- Bel Air/Artisan Tile Double-Eagle Bel Air Tile Estate Tile 11110,41" ____ . \\\\ ,\ \ \„• 17• \\ \ �iT N ,T ,,‘„,, \�„12 99' \I-12 99' \I_________12 99' r\10 12• 9• Artisan Tapered Slate Tile Ponderosa Tile Double-Eagle Ponderosa Tile Golden Eagle Tile \ . \\\NN \ir 1\11,. -\,7° \ --\,,.\\S \/OP\ \ ,J-N1 2°'\ 91R 679• \\ ` 9,9' ri,_67/r Smooth Ridge Trim Tile Smooth Rake Trim Tile Brushed Ridge Trim Tile Brushed Rake Trim Tile FIGURE 1-FIELD TILE AND TRIM UNITS EAGLE . CFLORIDA FIGURE 2-EAGLE ROOFING PRODUCTS LOGO FIGURE 3-FLORIDA LOGO