HomeMy WebLinkAboutUntitled City of Arcadia,CA Permit NO. Mech-18-0845
•
Development Services Department . AS Permit Type:Mechanical
240 West Huntington Drive,Post Office Box 60021
Arcadia,CA 91066-6021 Work Classification:HVAC Repair/Replace
(626)574-5416 Permit Status:Issued
ARCADIA Issue Date:05/22/2018 Expiration: 11/18/2018
Addr NO. Dir Prefix Street Name Street Suffix Unit City,State,Zip Parcel Number
120 Santa Cruz RD Arcadia,CA 5775016011
Contacts
SELA NAZARIAN Owner W C HEATING&AIR CONDITIONING HVAC Contractor(C-20)
120 SANTA CRUZ RD INC*
41085 GOLDEN GATE CIR,MURRIETA,CA 92562
(951)600-0700
Description:REPLACE HVAC IN SAME LOCATION.HERS Valuation: S 0.00 Tenant
REQUIRED FOR FINAL
Total Sq Feet: 0.00 Plan Check# Plan#
Fees Amount Payments Amount Paid
Compressor 3-5 Ton(3 to 15 hp) $34.29 Total Fees $98.38
Furnace or Burner cr 100,000 BTU $18.74 Cash/Receipt#REC-001218-2018 $98.38
Mechanical Permit Issuance Fee $44.35
Solid Waste Management Fee 2 $1 Amount Due: $0.00
.00
Total: $98.38
iv COMPLETED
CALLS FOR INSPECTIONS
Request for inspection by telephone at 626-574-5450. Leave a message
requesting the address,timeframe and what inspection item is needed.
This permit/plan review expires by time limitation and becomes null and
void if the work authorized by the permit is not commenced within 180 days
from the date of issuance or if the permit is not obtained within 180 days
from the date of plan submittal.This permit expires and becomes null and
void if any work authorized by this permit is suspended or abandoned for 180
consecutive days or if no progressive work has been verified by a City of
Arcadia building inspector for a period of 180 cons cutive days.
‘-zoe /4"- 1‘17(
7-/7-4 2/14 cTE_
4-
11°P
May 22,2018
Issued By: Date
May 22,2018 Page 1 of 1
PERMIT/PLAN REVIEW APPLICATION
is
144b• t Development Services Department,240 West Huntington Drive,Post Office Box 60021
,/ Arcadia,CA 91066-6021, (626)574-5416,Fax (626)447-9173
City off► .
Arcadia,
LICENSED CONTRACTOR'S DECLARATION WORKERS'COMPENSATION DECLARATION
[VI hereby affirm under penalty of perjury that I am licensed under provisions of I hereby affirm under penalty of perjury one of the following:
Chapter 9(commencing with Section 7000,of Division 3 of the Business and
Professions Code, d my license is in full forceAnd effect. ❑ I have and will maintain a certificate of consent to self-insure for workers'
Eicense Class License No. + Exp. Date /4 7 compensation, as provided for by Section 3700 of the Labor Code, for the
performance of the work for which this permit is issued.
Signature of Contractor
OWNER-BUILDER DEC ARA ON Ir -and and will maintain workers'compensation insurance,as required by Section
❑ I hereby affirm under penalty of perjury that I am exempt from the Contractors 3700 of the Labor Code,for the performance of the work for which this permit
License Law for the following reason(Section 7031.5,Business and Professions is issued.My workers'compensation insurance carrier and policy numbers are:
Code.Any city or county which requires a permit to construct,alter,improve, Carrier f)['_j2 s
demolish,or repair any structure,prior to its issuance,also required the applicant Policy Number WC 61/C 1-0-1
for such permit to file a signed statement that he or she is licensed pursuant to the
provisions of the Contractors License Law(Chapter 9(commencing with Section (This section need not be completed if the permit is for one hundred dollars or less)
7000)of Division 3 of the Business and Professions Code)or that he or she is
exempt there from and the basis for the alleged exemption. Any violation of ❑ I certify that in the performance of the work for which this permit is issued,I shall
Section 7031.5 by any applicant for a permit subjects the applicant to a civil not employ any person in any manner so as to become subject to the workers'
penalty of not more than five hundred dollars($500)): compensation Laws of California,and agree that if I should become subject to the
workers'compensation provisions of Section 3700 of the Labor Code,I shall
❑I, as owner of the property, or my employees with wages as their sole forthwith corn ly with those provisions.
compensation,will do the work,and the structure is not intended or offered for 5— lin,
sale(Section 7044,Business and Professions Code:The Contractors License DateSignature
Law does not apply to an owner of property who builds or improves thereon,
or who does such work himself or herself or through his or her own
employees,provided that such improvements are not intended or offered for WARNING: Failure to secure Workers'Compensation co rage is unlawful,
sale.If,however,the building or improvement is sold within one(1)year of and shall subject an employer to criminal penalties and civil to one
completion,the owner-builder will have the burden of proving that he or she hundred thousand dollars($100,000),in addition to the cost of compensation,
did not build or improve for the purpose of sale). damages as provided for in Section 3706 of the Labor Code, interest, and
attorney's fees.
❑I, as owner of the property, am exclusively contracting with licensed
contractors to construct the project(Section 7044,Business and Professions
Code:The Contractors License Law does not apply to an owner of property CONSTRUCTION LENDING AGENCY
who builds or improves thereon,and who contracts for such projects with a I hereby affirm under penalty of perjury that there is a construction lending agency
contractor(s)licensed pursuant to the Contractors License Law). for the performance of the work for which this permit is issued (Section 3097,
Civil Code).
❑ I am exempt under Section 7044,Business and Professions Code,for this reason:
Lender's Name
Date Signature Lender's Address
IMPORTANT: APPLICATION IS HEREBY MADE TO THE BUILDING OFFICIAL FOR A PERMIT SUBJECT TO THE CONDITIONS AND
RESTRICTIONS SET FORTH ON THIS APPLICATION AND THE FOLLOWING:
1. The City's approved plans and permit inspection card must remain on the job site for use by City inspection personnel.
2. Final inspection of the work authorized by this permit is required.A Certificate of Occupancy must be obtained prior to use and occupancy of new buildings
and structures.
3. Per South Coast Air Quality Management District(AQMD)regulations,renovation and remodeling work that results in the removal,stripping,or altering
of asbestos containing materials requires an asbestos survey and removal prior to disturbing the asbestos. Please contact AQMD at(909)396-2000 for
further information.
Name �'. LLI / S --4111M. Title C
PRINT NAME
I certify that I have read this application and state that the above information is correct and that I am the owner or duly authorized agent of the owner.
I agree to comply with all City ordinances and State Laws relating to building construction. I hereby authorize representatives of the City of
Arcadia to enter upon the above-mentioned p party for inspection purposes. �j
Signature Date 2./ ' s
00,1FORNI ( 1
,. a �h:`
'
AFFIDAVIT SELF-CERTIFICATION
FOR COMPLIANCE OF SMOKE ALARMS
AND CARBON MONOXIDE ALARMS
Property Address: 4-0 ,5e1CocU- Z .hof, Aft Urex ( -9i007
Permit Number: (01P C h lg _ D g`'f.5
Brief Job Description: N(44 C 6 t io 00 e A
Number of smoke alarms installed:
Number of carbon monoxide alarms installed:
When alterations, repairs or additions requiring a permit occur, or sleeping rooms are created,
Smoke alarms shall be installed in each sleeping room, and outside each separate
sleeping area in the immediate vicinity of the bedrooms, and on each additional story of the
dwelling, including basements and habitable attics as required by Section R314 of the 2016
California Residential Code (CRC) and California Health and Safety Code Section 13113.7.
For dwellings or sleeping units containing fuel burning appliances or having attached
garages, carbon monoxide alarms shall be installed outside each separate sleeping
area in the immediate vicinity of the bedrooms, and on each additional story of the
dwelling, including basements as required by Section R315 of the of the 2016 California
Residential Code (CRC).
Multi-purpose alarms (combination carbon monoxide and smoke alarms) may be used.
All alarms shall comply with requirements for listing and approval by the Office of the State Fire
Marshal. http://osfm.fire.ca.qov/licensinglistings/licenselistino bml searchcotest.php
As owner of the above referenced property, I hereby certify that the smoke alarms and carbon
monoxide alarms have been installed in accordance with the manufacturer's instructions and in
compliance with the code sections referenced above.
I declare under penalty of perjury that the foregoing is true and correct, and that this
declaration was executed on (Date) t - 010 - t`• at Arcadia, California.
Owner's Name (printed/typed): . eioc2 ilia-Z a k`0.v'
Signature of Owner: 5 >--
This affidavit must be returned to the City of Arcadia inspector prior to final inspection
SMOKE ALARM AND CARBON MONOXIDE ALARM LOCATIONS
,
Guest Room )Jj
O Bathroom
U Storage
16 gi
Family Room --
Garage
FIRST FLOOR PLAN
0= SMOKE ALARM I = CARBON MONOXIDE ALARM
Ms at
Bath
Pi Master Bedroom
Dining Room Kitchen 1)
— Bad
Ball U Closet
l Closet Closet
Family Room
0
Bedroom Bedroom
SECOND FLOOR PLAN
4)= SMOKE ALARM I = CARBON MONOXIDE ALARM
I
. --
CHIMNEYS AND VENTS
I gas input rate entering that segment and its total (3) An approved cap or roof assembly shall be attached
height. [NFPA 54:12.7.4.3] to the terminus of a single-wall metal pipe. [NEPA
>> 802.6.5 Support of Gas Vents. Gas vents shall be 54:12.8.3]
I supported and spaced in accordance with the manufac- 802.7.3 Installation with Appliances Permitted by
turer's installation instructions. [NFPA 54:12.7.5] Table 802.4.Single-wall metal pipe shall not be used as
)> 802.6.6 Marking. In those localities where solid and a vent in dwellings and residential occupancies. [NFPA
liquid fuels are used extensively, gas vents shall be 54:12.8.4.1]
permanently identified by a label attached to the wall or 802.7.3.1 Limitations.Single-wall metal pipe shall be
ceiling at a point where the vent connector enters the gas used for runs directly from the space in which the
vent.The label shall read:"This gas vent is for appliances appliance is located through the roof or exterior wall
that burn gas. Do not connect to solid or liquid-fuel- to the outer air.A pipe passing through a roof shall
burning appliances or incinerators." The Authority extend without interruption through the roof flashing,
Having Jurisdiction shall determine whether its area roof jacket,or roof thimble.[NFPA 54:12.8.4.2]
constitutes such a locality.[NFPA 54:12.7.6] 802.7.3.2 Attic or Concealed Space. $ifIgiVRIPTO1
802.7 Single-Wall Metal Pipe.Single-wall metal pipe shall be X11 not 0A110.8riumn .'-,I attic
constructed of galvanized sheet steel not less than 0.0304 of an or cone space ail shalI not ass i ..,_. ., attic,
inch(0.7722 mm)thick or of other approved,noncombustible, insid orisp or [NFPA
corrosion-resistant material. [NFPA 54:12.8.1] 54:12.8.4.3]
802.7.1 Cold Climate. Uninsulated single-wall metal 802.7.3.3 Incinerator Single-wall metal pipe used
pipe shall not be used outdoors for venting appliances in for venting an incinerator shall be exposed and
regions where the 99 percent winter design temperature readily examinable for its full length and shall have
is below 32°F(0°C). [NFPA 54:12.8.2] required clearances maintained.
802.7.2 Termination. The termination of single-wall 802.7.3.4 Clearances. Minimum clearances from
metal pipe shall comply with the following requirements: single-wall metal pipe to combustible material shall
be in accordance with Able 802.7.3.4.Reduced clear-
(1) Single-wall metal pipe shall terminate not less than ances from single-wall metal pipe to combustible
5 feet(1524 mm)in vertical height above the highest material shall be as specified for vent connectors in
connected appliance draft hood outlet or flue collar. Table 303.10.1.[NFPA 54:12.8.4.4]
(2) Single-wall metal pipe shall extend not less than 2 802.7.3.5 Combustible Exterior Wall. A single- I«
feet (610 mm) above the highest point where it wall metal pipe shall not pass through a combustible
passes through a roof of a building and not less than exterior wall unless guarded at the point of passage
2 feet(610 mm)exceeding a portion of a building by a ventilated metal thimble not smaller than the
within a horizontal distance of 10 feet(3048 mm). following:
(See Figure 802.5.4) (1) For listed appliances with draft hoods and appli-
ances listed for use with Type B gas vents,the
TABLE 802.7.3.4 <<
CLEARANCE FOR CONNECTORS'
[NFPA 54:TABLE 12.8.4.4]
MINIMUM DISTANCE FROM COMBUSTIBLE MATERIAL(Inches)
APPLIANCE LISTEDTYPE B LISTEDTYPE L SINGLE-WALL FACTORY-BUILT
GAS VENT MATERIAL VENT MATERIAL METAL PIPE CHIMNEY SECTIONS
• Listed appliance with draft hoods and appliance listed As listed As listed 6 As listed
for use with Type B gas vents
Residential boilers and furnaces with listed gas 6 6 9 As listed
conversion burner and with draft hood
Residential appliances listed for use with Type L vents Not permitted As listed 9 As listed
Listed gas-fired toilets Not permitted As listed As listed As listed
Unlisted residential appliances with draft hood Not permitted 6 9 As listed
Residential and low-heat appliance other than those Not permitted 9 18 As listed
'above
Medium-heat appliance Not permitted Not permitted 36 As listed
For SI units:1 inch=25.4 mm
-=-.4„.„...........N
These clearances shall apply unless the installation instructions of a listed appliance or connector specify different clearances,in which case the listed clear-
ances shall apply.
2016 CALIFORNIA MECHANICAL CODE 137