Loading...
HomeMy WebLinkAboutUntitled City of Arcadia, CA Permit NO.SIGN-18-1140 i1 Development Services Department Permit Type:Sign r `.Il 240 West Huntington Drive,Post Office Box 60021 t 1 ` Arcadia,CA 91066-6021 Work Classification:Sign-Illuminated (626)574-5416 Permit Status:Issued ARCA Ii)tA Issue Date:07/02/20181 Expiration: 12/29/2018 Addr NO. Dir Prefix Street Name Street Suffix Unit City,State,Zip Parcel Number 1435 S Baldwin AVE Arcadia, CA 5383031034 Contacts ROSEWOOD INVESTMENT OF ARCADIA Owner AD ELECTRICAL ADVERTISING INC' Electrical Contractor 1807 SAN GABRIEL BLVD (C-10) 9437 VALLEY BLVD,ROSEMEAD,CA 91770 (626)448-1166 PAUL@ADELECTRICSIGNS.COM Description:2 LED ILLUMINATED SIGNS FOR SWEETHONEY Valuation: 5 5.000.00 Tenant SWEETHONEY DESSERT DESSERT Total Sq Feet: 0.00 Plan Check# Plan# Fees Amount Payments Amount Paid Building Issuing Fee $44.35 Total Fees $481.94 Building Permit Fees $153.75 Cash/Receipt#REC-001606-2018 $481.94 Electrical Permit Issuance Fee $44.35 Amount Due: $0.00 Sign and Branch Circuit $124.26 Sign Connection $31.10 Sign Plan Review $76.88 Solid Waste Management Fee $6.25 Solid Waste Management Fee 2 $1.00 Total: $481.94 CALLS FOR INSPECTIONS Request for inspection by telephone at 626-574-5450. Leave a message 25_x_` ` requesting the address,timeframe and what inspection item is needed. This permit/plan review expires by time limitation and becomes null and I COMpIETED void if the work authorized by the permit is not commenced within 180 days from the date of issuance or if the permit is not obtained within 180 days from the date of plan submittal.This permit expires and becomes null and void if any work authorized by this permit is suspended or abandoned for 180 consecutive days or if no progressive work has been verified by a City of Arcadia building inspector for a period of 180 consecutive days. July 02, 2018 Issued By: Date July 02,2018 Page 1 of 1 a - a IA PERMIT/PLAN REVIEW APPLICATION 04iN • E4v, Development Services Department,240 West Huntington Drive,Post Office Box 60021 .a', Arcadia, CA 91066-6021,(626)574-5416,Fax(626)447-9173 City of Arcadia LICENSED CONTRACTOR'S DECLARATION WORKERS'COMPENSATION DECLARATION ❑ I hereby affirm under penalty of perjury that I am licensed under provisions of I hereby affirm under penalty of perjury one of the following: Chapter 9(commencing with Section 7000,of Division 3 of the Business and Professions Code,and my license is in full force and effect. 1:1 I have and will maintain a certificate of consent to self-insure for workers' License Class C. License 1 o. Ifi .'9J1 Exp. Date ll;lbt compensation, as provided for by Section 3700 of the Labor Code, for the Signature of Contractor ! -. performance of the work for which this permit is issued. �S ❑ I have and will maintain workers'compensation insurance,as required by Section OWNER-BUILDE DECLA' •TION 3700 of the Labor Code,for the performance of the work for which this permit ❑ I hereby affirm under penalty of perjury that I am exempt from the Contractors is issued.My workers'compensation insurance carrier and policy numbers are: License Law for the following reason(Section 7031.5,Business and Professions a Code.Any city or county which requires a permit to construct,alter,improve, artier CNA. P OteLTION INS. M.e tatr demolish,or repair any structure,prior to its issuance,also required the applicant 411I O1 gS 7 for such permit to file a signed statement that he or she is licensed pursuant to the Policy Number provisions of the Contractors License Law(Chapter 9(commencing with Section (This section need not be completed if the permit is for one hundred dollars or less) 7000)of Division 3 of the Business and Professions Code)or that he or she is exempt there from and the basis for the alleged exemption. Any violation of .0I certify that in the performance of the work for which this permit is issued,I shall Section 7031.5 by any applicant for a permit subjects the applicant to a civil not employ any person in any manner so as to become subject to the workers' penalty of not more than five hundred dollars($500)): compensation Laws of California,and agree that if I should become subject to the workers'compensation provisions of Section 3700 of i e Labor Code,I shall ❑I, as owner of the property, or my employees with wages as their sole forthwith comply with those provisions. - tillik. compensation,will do the work,and the structure is not intended or offered for c' sale(Section 7044,Business and Professions Code:The Contractors License Date,�'��S Signature f��.1���)� Law does not apply to an owner of property who builds or improves thereon, or who does such work himself or herself or through his or her own employees,provided that such improvements are not intended or offered for WARNING: Failure to secure Workers'Compensation coverage is unlawful, sale.If,however,the building or improvement is sold within one(1)year of and shall subject an employer to criminal penalties and civil fines up to one completion,the ownerbuilder will have the burden of proving that he or she hundred thousand dollars($100,000),in addition to the cost of compensation, did not build or improve for the purpose of sale). damages as provided for in Section 3706 of the Labor Code, interest, and attorney's fees. ❑I, as owner of the property, am exclusively contracting with licensed contractors to construct the project(Section 7044,Business and Professions Code:The Contractors License Law does not apply to an owner of property CONSTRUCTION LENDING AGENCY who builds or improves thereon,and who contracts for such projects with a I hereby affirm under penalty of perjury that there is a construction lending agency contractor(s)licensed pursuant to the Contractors License Law). for the performance of the work for which this permit is issued (Section 3097, Civil Code). 0 I am exempt under Section 7044,Business and Professions Code,for this reason: Lender's Name Date Signature Lender's Address IMPORTANT: APPLICATION IS HEREBY MADE TO THE BUILDING OFFICIAL FOR A PERMIT SUBJECT TO THE CONDITIONS AND RESTRICTIONS SET FORTH ON THIS APPLICATION AND THE FOLLOWING: 1. The City's approved plans and permit inspection card must remain on the job site for use by City inspection personnel. 2. Final inspection of the work authorized by this permit is required.A Certificate of Occupancy must be obtained prior to use and occupancy of new buildings and structures. 3. Per South Coast Air Quality Management District(AQMD)regulations,renovation and remodeling work that results in the removal,stripping,or altering of asbestos containing materials requires an asbestos survey and removal prior to disturbing the asbestos. Please contact AQMD at(909)396-2000 for further information. Name Tt i PCN TON Ttt Fir Title LONTIZACTOg- HUNT NAME I certify that I have read this application and state that the above information is coirect and that I am the owner or duly authorized agent of the owner. I agree to comply with all City ordinances and State Laws relating to building construction. I hereby authorize representatives of the City of Arcadia to enter upon the above-mentioned property for inspection purposes. Signature (Date 7/ 7', iiito 129" O 12. L J � ROUTINGrACTION — —�� SLb;r_lc-qy_T_„ „2. Date and ,,.. �\�P�P3/4z:,* *See 26" Initials of ,R9,°- No aQF , P Notes tgO D) g Il it E R 4 / 111/2" Planning ZChecicer S Qe G° P Cf on Sheet# • / - -- I ---/- 14 164" yl 1T fi- 12 iv.//yriE174 en 1 n0 TM, -; ; S'Jte-!A I k EVERSEHALO-1L , A ± I I . A , _LOGO Trees L ' _• — -L- 4 -THICK-WH1TE-A 'USHTHRU LETTERS -, F CE: .09 ALUMINUM PAINTED BURGUNDY y _ BACKS: CLEAR LEXAN FOR HALO SPILL — SPACERS: 1"THK PAINTED TO BURGUNDY ._ ,�- } ' - "" RETURNS: 3" DEEP (x.063)ALUMINUM PAINTED BURGUNDY Ei2 S W E E T H O N E Y ILLUMINATION: WHITE LUMIFICIENT LEDs WITH LUMIFICIENT POWER SUPPLIES off, DESSERT 1 /p ' ' a r .,� I • 7C4D[OKCAU D @ . Q R 4 - LETTERS: 3" DEEP, DUAL ILLUMINATED CHANNEL LETTERS FACE: #7328 WHITE ACRYLIC TRIMCAP: 3/4"WHITE TRIMCAPS SPACERS: 1"THK PAINTED TO BLACK North Elevation RETURNS: 3" DEEP BLACK ALUMINUM RETURNS ILLUMINATION: FRONT:WHITE LED, BACK: BLUE LED 4----- 34'-2" MI SIGNS This sign is Intended to be installed In accordance with the requirements of Article 600 of the National Electrical Code and/or other applicable local codes.This Includes proper grounding and bonding of the sign. ELECTRICAL ADVERTISING INC JOB LOCATION APPROVED 9437 VALLEY BL., ROSEMEAD, CA 91770 TEL: 626-448-1166 FAX: 626-448-1161 1435 S. Baldwin Ave, Arcadia, CA 91007 14 105" 1i2 ' YggH [ (O) \ 7 9,. D) E CC C ER CI 9" ` F 133" I'l lc i2 34'-2" > fill 00 SPECIFICATIONS: REVERSE HALO ILLUMINATED CHANNEL LOGO • LETTERS: 3/4"THICK WHITE ACRYLIC PUSH THRU LETTERS FACE: .09 ALUMINUM PAINTED BURGUNDY ` `- _ mi2 SWEETHONEY BACKS: CLEAR LEXAN FOR HALO SPILL mg D E `S S E` R T SPACERS: 1"THK PAINTED TO BURGUNDY _ RETURNS: 3" DEEP (x.063)ALUMINUM PAINTED BURGUNDY ILLUMINATION: WHITE LUMIFICIENT LEDs WITH LUMIFICIENT POWER SUPPLIES f . . 1 • ) � 1CQ4DEOKC 'V Q RRQ 4 LETTERS: 3" DEEP, DUAL ILLUMINATED CHANNEL LETTERS FACE: #7328 WHITE ACRYLIC TRIMCAP: 3/4"WHITE TRIMCAPS SPACERS: 1"THK PAINTED TO BLACK South Elevation RETURNS: 3" DEEP BLACK ALUMINUM RETURNS ILLUMINATION: FRONT:WHITE LED, BACK: BLUE LED MI SIGNSThis sign is intended to be Installed in accordance with the requirements of Article 600 of the National Electrical Code and/or other applicable local codes.This Includes proper grounding and bonding of the sign. ELECTRICAL ADVERTISING INC JOB LOCATION APPROVED 9437 VALLEY BL., ROSEMEAD, CA 91770 TEL: 626-448-1166 FAX: 626-448-1161 I 1435 S. Baldwin Ave, Arcadia, CA 91007 • jairm TYPICAL WALL FRAMING (--�V27g g V LJ LJ O IX_wI g M TYPICAL WALL SURFACE ; g II /1�7� La Li j Eta O Q ALUMINUM FACE t,l WELDED TO RETURNS 3" E 125 FACES,.063 RETURNS 1. 040 ALUMINUM RETURNS 5,. 1" TRIMCAP WITH#8 X'h"SCREWS / E LIGHT EMITTING DIODES(LEDs) I 4 LOW VOLTAGE WIRING FROM LED TO LEO CLASS 2 LOW VOLTAGE WIRING(NO CONDUIT LIGHT EMITTING DIODES(LEDs) 5 REQUIRED) D 4 THICK ACRYLIC PUSH THRU LTTTERS "Ill ) LOW VOLTAGE WIRING FROM LED TO LED 0 CLEAR LEXAN BACK s © 0 ACRYLIC FACE CHANNEL LETTERS-I. 1. 1 0 CLASS 2 LOW VOLTAGE I WRING(NO CONDUIT DRILLED HOLE THRU WALL = I SPUOPPLYWER CLEAR LEXAN BACK REQUIRED) FOR WIRE CONNECTIONS AND I 1; I1El FILLED WITH SILICONE TO PREVENT '— DRILLED HOLE THRU WALL I WATER PENETRATION ( i i' FOR WIRE CONNECTIONS AND ik€ POWER ©20A 120-277VAC DISCONNECT SWITCH J., FILLED WITH SILICONE PENETRATINT SUPPLY J-BOX WITH II; le DISCO 120-277VAC ©20A 120-277VAC DISCONNECT SWITCH ' DISCONNECT ©THREADED NIPPLE AND COUPLING I SWITCH © THREADED NIPPLE AND COUPLING • ` ' J-BOX WITH #10 x 3'/x"DRIVE SCREWS I c Q ...4•,- MINIMUM I 120-277VAC MINIMUM THREE(3)PER LETTER s I, 1 FLEX(FLEXIBLE CONDUIT)/ la r, Z FLEX(FLEXIBLE = DISCONNECT OR AS REQUIRED PER FIELD CONDITIONS I LIQUID TIGHT CONNECTIONS 1'''A"SPACERS REQUIRED > CONDUIT)/ SWITCH s LIQUID TIGHT #10 x 3'/"DRIVE SCREWS MINIMUM FIVE(5)PER LETTER 1 --F.,- CHANNEL CHANNEL LETTER RETURNS .....". s CONNECTIONS OR AS REQUIRED,1"SPACERS REQUIRED COUNTER SUNK SCREWED s CHANNEL LETTER RETURNS COUNTER SUNK SCREWED I TO CLEAR LEXAN ANGLE CLIPS s PRIMARY TO CLEAR LEXAN ANGLE CLIPS �I pito ONE(1)'/.'WEEP HOLE BEHIND LETTER S POWER ONE(1)'A"WEEP HOLE BEHIND LETTER LOCATED PRIMARY WER LOCATED AT ALL AREAS THAT MAY COLLECT WATER s AT ALL AREAS THAT MAY COLLECT WATER "THIS SIGN IS SUITABLE FOR WET LOCATIONS" S "THIS SIGN IS SUITABLE FOR WET LOCATIONS" LABEL SIGN WITH MINIMUM 1/8"COPY LABEL SIGN WITH MINIMUM 1/8"COPY •• s TYPICAL SECTION DETAIL TYPICAL SECTION DETAIL •n\/ SCALE:NTS SCALE:NTS PLEASE REFER TO THE NUMBERED ITEMS BELOW MAIN POWER FOR INCORPORATED INSTALL INSTRUCTIONS. I J• PRIMARY POWER LISTED INSTRUCTIONS TO BE FOUND WITH ACTUAL SIGNAGE GROUNDING WIRE ► (NUMBERED ITEMS CORRESPOND TO SECTION DETAIL) I NEUTRAL WIRE ITEM# DESCRIPTION SECONDARY POWER POWER SUPPLY f CHANNEL LETTERS 2 DISCONNECT SWITCH Z7 3 THREADED NIPPLE AND COUPLING(FLEX CONNECTOR) This sign IS Intended to be Installed In accordance with 4 CLASS 2 LOW VOLTAGE WIRING(NO CONDUIT REQUIREDCHiNxE� nL CHANNEL the requirements of Article 600 of the National Electrical 5 POWER SUPPLY Code and/or other Applicable.This includes proper 6 FLEX(FLEXIBLE CONDUIT)/LIQUID TIGHT CONNECTIONS 1 grouding and bonding of the sign. •DISCONNECT SWITCH AT FAR LEFT OR RIGHT OF END LETTER "VERIFY PLACEMENT PRIOR TO FABRICATION The location of the disconnect switch after installation shall comply iwth Article 600.6(A) (1) of the National LETTER LAYOUT-PLAN VIEW Electrical Code. SIGfIS NOT TO SCALE MI This sign is Intended to be installed in accordance with the requirements of Article 600 of the National Electrical Code and/or other applicable local codes.This includes proper grounding and bonding of the sign. ELECTRICAL ADVERTISING INC JOB LOCATION APPROVED 9437 VALLEY BL., ROSEMEAD, CA 91770 TEL: 626-448-1166 FAX: 626-448-1161 I 1435 S. Baldwin Ave, Arcadia, CA 91007