Loading...
HomeMy WebLinkAboutUntitled ..••• City of Arcadia, CA Permit NO.SOLR-18-0862 Development Services Department Permit Type:Solar 240 West Huntington Drive,Post Office Box 60021 Work Classification:Residential Solar Arcadia,CA 91066-6021 (626)574-5416 Permit Status:Issued ARCADI A Issue Date:05/24/2018 Expiration: 11/20/2018 Addr NO. Dir Prefix Street Name Street Suffix Unit City,State,Zip Parcel Number 2501 S 2nd AVE Arcadia,CA 57890190431 Contacts ' KELLY LAM Owner SUNRUN Contractor 2501 2ND AVE,ARCADIA,CA 91006 9220 HALL RD,DOWNEY,CA 90241 L (626)716-5133 (562)869-1594 Description:ROOF MOUNT SOLAR SFR 19/1 Valuation: S 0.00 Tenant Total Sq Feet: 0.00 Plan Check# Plan# Fees Amount Payments Amount Paid Building Plan Check Fee Residential $50.00 Total Fees $300.91 Electrical Permit Issuance Fee $44.35 Cash/Receipt#REC-001248-2018 $300.91 Fire Plan Check Fee Residential $50.00 Amount Due: $0.00 Inverters $77.78 Panels $77.78 Solid Waste Management Fee 2 $1.00 Total: $300.91 6 6-f g CALLS FOR INSPECTIONS 1410 , Request for inspection by telephone at 626-574-5450. Leave a message requesting the address,timeframe and what inspection item is needed. This permit/plan review expires by time limitation and becomes null and void if the work authorized by the permit is not commenced within 180 days 4/1i from the date of issuance or if the permit is not obtained within 180 days compLETEDfrom the date of plan submittal.This permit expires and becomes null and void if any work authorized by this permit is suspended or abandoned for 180 consecutive days or if no progressive work has been verified by a City of Arcadia building inspector for a period of 180 consecutive days. May 24, 2018 Issued By: Date May 24,2018 Page 1 of 1 .F ' PERMIT/PLAN REVIEW APPLICATION • Development Services Department,240 West Huntington Drive,Post Office Box 60021 , Arcadia, CA 91066-6021, (626)574-5416,Fax(626)447-9173 City of Arcadia LICENSED CONTRACTOR'S DECLARATION WORKERS'COMPENSATION DECLARATION ❑ I hereby affirm under penalty of perjury that I am licensed under provisions of I hereby affirm under penalty of perjury one of the following: Chapter 9(commencing with Section 7000,of Division 3 of the Business and Professions Code,and my license is in full force and effect. / El have and will maintain a certificate of consent to self-insure for workers' License Class (— `o Lie e No. —7 S C 1 N Exp. Date`0l°lf Y compensation, as provided for by Section 3700 of the Labor Code, for the <\� performance of the work for which this permit is issued. Signature of Contractor OWNER-BUILDER DECLARATION ❑ I have and will maintain workers'compensation insurance,as required by Section 1:3I hereby affirm under penalty of perjury that I am exempt from the Contractors 3700 of the Labor Code,for the performance of the work for which this permit License Law for the following reason(Section 7031.5,Business and Professions is issued.My workers'compensation insurance carrier and policy numbers are: Code.Any city or county which requires a permit to construct,alter,improve, Carrier 7'� €L __i. <— demolish,or repair any structure,prior to its issuance,also required the applicant Number ✓�t;`tet`.1 4't; for such permit to file a signed statement that he or she is licensed pursuant to the provisions of the Contractors License Law(Chapter 9(commencing with Section (This section need not be completed if the permit is for one hundred dollars or less) 7000)of Division 3 of the Business and Professions Code)or that he or she is exempt there from and the basis for the alleged exemption. Any violation of ❑ I certify that in the performance of the work for which this permit is issued,I shall Section 7031.5 by any applicant for a permit subjects the applicant to a civil not employ any person in any manner so as to become subject to the workers' penalty of not more than five hundred dollars($500)): compensation Laws of California,and agree that if I should become subject to the workers'compensation provisions of Section 3700 of the Labor Code,I shall ❑I, as owner of the property, or my employees with wages as their sole forthwith comply with those provisions. compensation,will do the work,and the structure is not intended or offered for S ' ti. q/ sale(Section 7044,Business and Professions Code:The Contractors License Date Signature Law does not apply to an owner of property who builds or improves thereon, or who does such work himself or herself or through his or her own employees,provided that such improvements are not intended or offered for WARNING: Failure to secure Workers'Compensation coverage is unlawful, sale.If,however,the building or improvement is sold within one(1)year of and shall subject an employer to criminal penalties and civil fines up to one completion,the owner-builder will have the burden of proving that he or she hundred thousand dollars($100,000),in addition to the cost of compensation, did not build or improve for the purpose of sale). damages as provided for in Section 3706 of the labor Code, interest, and attorney's fees. ❑I, as owner of the property, am exclusively contracting with licensed contractors to construct the project(Section 7044,Business and Professions Code:The Contractors License Law does not apply to an owner of property CONSTRUCTION LENDING AGENCY who builds or improves thereon,and who contracts for such projects with a I hereby affirm under penalty of perjury that there is a construction lending agency contractor(s)licensed pursuant to the Contractors License Law). for the performance of the work for which this permit is issued (Section 3097, Civil Code). ❑ I am exempt under Section 7044,Business and Professions Code,for this reason: Lender's Name Date Signature Lender's Address IMPORTANT: APPLICATION IS HEREBY MADE TO THE BUILDING OFFICIAL FOR A PERMIT SUBJECT TO THE CONDITIONS AND RESTRICTIONS SET FORTH ON THIS APPLICATION AND THE FOLLOWING: 1. The City's approved plans and permit inspection card must remain on the job site for use by City inspection personnel. 2. Final inspection of the work authorized by this permit is required.A Certificate of Occupancy must be obtained prior to use and occupancy of new buildings and structures. 3. Per South Coast Air Quality Management District(AQMD)regulations,renovation and remodeling work that results in the removal,stripping,or altering of asbestos containing materials requires an asbestos survey and removal prior to disturbing the asbestos. Please contact AQMD at(909)396-2000 for further information. Name o►r"''Z°- Title ree . �9oN( P NAME I certify that I have read this application and state that the above information is correct and that I am the owner or duly authorized agent of the owner. I agree to comply with all City ordinances and State Laws relating to building construction. I hereby authorize representatives of the City of Arcadia to enter upon t ve-mentioned property for inspection purposes. r, Signature Date S= -ZK-td 4- ARRAY TRUE MAG PV AREA SITE PLAN-SCALE=1/16"=1'-0" PITCH AZIM AZIM (SQFT) AR-01 18° 180° 168' 74.4 AR-02 18° 270' 258° 167.3 AR-03 18' 0' -12' 111.6 MP (N)ARRAY AR-03 (E)RESIDENCE INV 7(E)GATE PL PL /CIE) PL PL I I EL' 12 FIRE SETBACKS-- (3' (3'TYP) — < \ . / / d / o • (N)ARRAY AR-02 _ • I'> 1 Al Z sunrun + 0 \' < CA CL#750184 a n ° ' . 9? ROOD. ECA 7. E PHONE 707 779 7406 FM 582699.159. �' II.I 121. PL P PL PL PL CUSTOMER RESIDENCE: KELLY LAM FIRE SETBACKS 2501 SOUTH 2ND TPP,ARCADIA, (18"TYP) (N)ARRAY AR-01 (E)GATE (E)DRIVEWAY CA,91006 TEL.(626)716-5133 APN it 5789-019-043 PROJECT NUMBER. 114R-501LAM DESIGNER: 949.705.3959 TYLER KINCAID SHEET SITE PLAN REV A.1 5/17/2018 PAGE PV-2.O sun1un� Structural Calculations for the Kelly Lam Residence PV Installation Date: 5/23/2018 Job Address: 2501 South 2nd TPP Arcadia, CA, 91006 Job Number: 114R-501LAM Scope of Work These calculations are for the existing roof framing which supports the new PV modules as well as the attachment of the PV system to existing roof framing. All PV mounting equipment shall be designed and installed per manufacturer's approved installation specifications. Calculation Index Sheet Description 2 Structural Geometry, Live Load,Snow Load,Wind Load, Dead Load, & Roof(1) Framing Check 3 Roof(1) Framing Check Continued, Roof Attachment Check,Seismic Check, &Scope of Work Engineering Calculations Summary Code: 2016 California Building Code ASCE 7-10 Snow Load: S= 0 psf Live Load: LL= 20 psf Wind: Wind Speed Ult. (V)= 110 mph Exp. = B PV Dead Load: DPV= 3.0 psf Sincerely, Sage Lopez, P.E. r* t__ -10�s Civil Engineer No. 5870 (,", ao Sunrun, Inc ' Exp. ,i3°/IS' cry �_,,�p�!./ 44OF CAI07/ 133 Techno •:' • ., Suite 100, Irvine, CA 92618 I P 949.393.0993 Engineer:SVL tM Date: 5/23/2018 Job: 114R-501LAM Address: 2501 South 2nd TPP 1 IN • Arcadia, CA, 91006 2 of 3 Structrure Geometry: Mean Roof Height,hn = 24 ft Eave Height,he = 18 ft Buiding Length,L = 54 ft Building Width,B = 51 ft Module Area = 20 ft2 Roof Pitch,0 = 18 degrees Snow Load: Ground Snow Load,pg = 0 Fig.7-1 Wind Load: Basic Wind Speed(3s-gust) = 110 mph Figure 26.5-1A Building Occupancy Category = 2 Table 1.5-1 Wind Importance Factor,Iw = 1.00 Table 1.5-2 Exposure Category = B Sec 26.7.3 Topographic Factor,Kzr = 1.00 Equation 26.8-1 Adjustment Factor,it = 1.00 Figure 30.5-1 Edge Zone,a = 5.10 ft Figure 30.5-1 Uplift(0.6W) Zone 1(psf) Zone 2(psf) Zone 3(psf) Pnet30 = -19.40 -31.90 -47.90 Figure 30.5-1 Pnet=0.6 x]L x Kzr x Pnet30) = -11.64 -19.14 -28.74 Equation 30.5-1 Downward(0.6W) Zone 1(psf) Zone 2(psf) Zone 3(psf) Pnet30 = 11.40 11.40 11.40 Figure 30.5-1 Pnet=0.6 x it x KZr x Pnet30 = 9.60 9.60 9.60 Equation 30.5-1 Dead Load: Roof(1): Roof Walls-Exterior S Tile 9.0 psf Stucco 10.0 psf 5/8 OSB Sheathing 2.0 2x4 Studs @ 16" 2.0 2x10 Rafter @ 16"OC 3.0 Gypsum 3.0 Misc.(Ceiling,Insulation,etc.) 1.0 Misc.(Insulation,etc.) 2.0 PV System,Ppv 3.0 Total Roof DL= 18.0 psf Total Wall DL= 17.0 psf Roof(1)Framing Check: Roof Framing = 2x10 Rafter @ 16"OC Timber Species = Doug Fir-Larch#2 Max Beam Span = 16.00 ft b = 1.5 in d = 9.25 in Moment of Inertia,I. = 98.93 in' Section Modulus,S. = 21.39 in3 Bending Stress,Fb = 900 psi Elastic Modulus,Emin = 580000 psi Co(Wind) CD(Snow) CLS Cm Ct Wood Adjustment Factors: 1.60 1.15 1.10 1.00 1.00 CL CF Cfu C1 Cr 1.00 1.10 I 1.00 1.00 1.15 133 Technology Dr., Suite 100, Irvine, CA 92618 I P 949.383.0993 Engineer:SVL ta, Date: 5/23/2018 111"1* Job:Job: 114R-501LAM Address: 2501 South 2nd TPP I • • Arcadia, CA,91006 3 of 3 Roof(1)Framing Check Continued: PV Tributary Width,Wpx = 2.75 ft PV Tributary Length,Lpv = 5.3 ft PV Tributary Area,At = 14.7 ft2 PV Dead Point Load,Po=Ppv x At = 42 lb Roof Distributed Load,wDL = 19 plf Load Case: 0.6DL+0.6W (CD=1.6) Roof Zone = 1 Pup=Pnet X At+0.6 X PD X Cos(0) = 146 lb Mb(wind_up) = 599 lb-ft Fb'(wind)=Fb XCD XCLS XCM xCt XCL xCF XCfu XCi XCr = 2004 psi Mallowable=ST x Fb'(wind) = 3572 lb-ft > 599 OK Load Case: DL+0.6W (CD=1.61 Pdown=Pnet x At+PD x Cos(0) = 183 lb Mb(wind_down) = 1818 lb-ft Fb'(wind)=Fb XCD xCLS XCM XCt XCL xCF XCfu XCi xCr = 2004 psi Mallowable=ST x Fb'(wind) = 3572 lb-ft > 1818 OK Rafter Attachments:0.6D+0.6W(Zone 2) Puplift=At x Pnet = 255 lb Connector Uplift Capcity per SnapNRack Test Results = 405 lb > 255 OK 5/16"Lag Screw Withdrawl Value = 266 lb/in Table 12.2A-NDS Lag Screw Penetration = 2.50 in Allowable Capacity with Co = 1064 lb > 255 OK Seismic Check: Existing Dead Load: Solar Dead Load: Arootexisting = 2754 ft2 Wpanel = 42 lb Wroofexisting = 41310 lb Numpanel = 19 Awallexisting = 3780 ft2 Wpanel_tot = 798 lb Wwallexisting = 64260 lb Wbos = 186 lb Wtotal = 105570 lb Warray = 984 lb %increase=(Wtotal+Warray)/Wtotal = 106554 *100%400% = 0.93% ** 105570 **The increase in weight as a result of the solar system is less than 10%of the existing structure and therefore no further seismic analysis is required. Limits of Scope of Work and Liability We have based our structural capacity determination on applicable building codes,professional engineering inspection and design experience,opinions and judgments.The calculations produced for this dwelling's assessment are only for the proposed solar panel installation referenced in the stamped plan set and were made according to generally recognized structural anlaysis standards and procedures. 133 Technology Dr., Suite 100, Irvine, CA 92618 I P 949.383.0993 5/16"0-18 X 1/4"-S.S.FLANGE NOTES: SNAPNRACK BOLT • 5/16"0 S.S.LAG SCREW MUST EMBED SNAPNRACK 5/16"0-18 X 1-1/4" COMPOSITION 2-1/2"INTO ROOF STRUCTURAL CHANNEL NUT S.S.FLANGE BOLT MEMBERS/RAFTERS ` FLASHING SNAPNRACK COMPOSITION \l,�� 7 FLA GE NUT • TORQUE ALL 5/16"0 HARDWARE TO THE L-FOOT CAN BE MOUNTED FOLLOWING: I IN ANY ORIENTATION .. SILVER S.S.10-16 FT-LBS •• BLACK S.S.7-9 FT-BLS SNAPNRACK 5/16"0-18 S.S. • RAILS CAN MOUNT TO EITHER SIDE OF SNAPNRACK �� FLANGE NUT L-FOOT(UPSLOPE VS DOWNSLOPE) STANDARD RAIL CHANNEL NUT SNAPNRACK ION 92 DEG lila \ COMPOSITION L-FOOT c\. ,�� �`` . , SNAPNRACK 4! �T% --2.4. COMPOSITION .� FASTEN L-FOOT SNAPNRACK ` FLASHING BASE TO ROOF STANDARD RAIL WITH LAG SCREW 5/16"0 S.S.LAG SCREW 5/16"0 S.S.FLAT WASHER 1 ROOF DECKING TYP SNAPNRACK L FOOT BASE 4,7 1 . 1111114111111111 COMPLETED INSTALLATION FLASHED L FOOT MOUNTING POINT FOR USE ON COMPOSITION ROOF SURFACES WITH LOW TO MODERATE TILT. RAILS CAN BE LEVELED UP TO 3"USING UP TO TWO .1 LEVELING SPACERS AS SHOWN IN"SERIES 100 RAIL LEVELING". -""111P,. .•,* J- 1A- sunrun REV DATE 1/162018 S100 PEN-D03: FLASHED L-FOOT TO RAFTER PAGE MOUNTING SNAPNRACK MOUNTINDETAIL — \ BONDING MID CLAMP // \ ASSEMBLY \ ( I ) \ ■I r �T� . ___ __ SS BONDING PIN \\_� —� — — = MODULE FRAME / F�}=� I I il RAIL \ / ' f BONDING CHANNEL NUT NOTE: 1. END CLAMPS USE SAME BONDING PIN DESIGN TO BOND MODULES TO RAIL 6-12 AWG BARE 5/16"-18 SS BOLT COPPER WIRE SS SPLIT LOCK WASHER -- — (TORQUE TO 16 FT-LBS) / \� / SNAPNRACK — — ,U, GROUND LUG —� --Atir-41. -- 1 .1-1/ Mill1 / -�K��- BONDING \ I, \ =&41 CHANNEL NUT \,... i I RAIL SS BONDING PINS NOTE: 1. ALL HARDWARE IS INCLUDED FROM MANUFACTURER 2. A MINIMUM OF ONE GROUND LUG IS TO BE INSTALLED ON EVERY CONTINUOUS ROW OF MODULES 3. GROUND LUG MAY BE INSTALLED IN EITHER RAIL CHANNEL ASSEMBLER: 4. GROUND LUG MAY BE INSTALLED SO GROUND WIRE IS PARALLEL OR PERPENDICULAR TO RAIL 5. ENSURE SPLIT LOCK WASHER IS INSTALLED ON TOP OF COPPER WIRE INSPECTOR: DESCRIPTION: DRAWN BY: MIKE WATKINS SNAPNRACK UL RACKING APPROVED BY: CODY NORMAN Sui ©pNJ rack REVISION: GROUNDING DETAILS F 1/20/2015 NEW ITEM Solar Mounting Solutions Sunrun South LLC 595 MARKET STREET,29TH FLOOR•SAN FRANCISCO,CA 94105 USA PART NUMBER: SCALE: — PHONE(415)580-6900•FAX(415)580$902 DNSDNS — THE INFORMAPON IN THIS CRANING IS CONFI0ENT1AL AND PROPRIETARY ANY JREPRCCUCTICN,DISCLOSURE,OR USE THEREOF IS PROH&TED IAI IHOUT TIE NRITTEN CONSENT OF SIRPIN SOUTH LLC. SS BONDING PIN BONDING SPLICE (4 TOTAL) ASSEMBLY / \� ci\::_tL'\i immipHr-1 SECTION A-A SS BONDING PIN, A TYP. ■ A NOTE: 1. ALL HARDWARE IS INCLUDED FROM MANUFACTURER 2. ALL SPLICES SHOULD HAVE 3 BOLTS TIGHTENED TO THE PROPER TORQUE(NEVER LEAVE OUT ANY BOLTS IN ANY SPLICE) • SILVER 5/16" HARDWARE= 10-16 FT-LBS • BLACK 5/16"HARDWARE =8-10 FT-LBS ASSEMBLER: 3. GAP RAILS 0.1"-0.2"AT ALL SPLICES INSPECTOR: DESCRIPTION: DRAWN BY: MIKE WATKINS _ SNAPNRACK UL RACKING APPROVED BY: CODY NORMAN SnapN rack REVISION: GROUNDING DETAILS F 1/20/2015 NEW ITEM Solar Mounting Solutions Sunrun South LLC 595 MARKET STREET.29TH FLOOR•SAN FRANCISCO.CA 94105 USA PART NUMBER: SCALE: — - PHONE(415)550-5900•FAX(415)5808902 DNS — T£INFORMATION INFORMATIONgi IN THS CRANING IS CONDENTUI AND PROPRETARY.ANY J REPRODUCTION.DISCLOSURE.OR USE THEREOF IS PROH91TE0 WITHOUT TE WRITTEN CONSENT OF SUNIUN SOUTH LLC. SERIES 100 UL ROOF MOUNT SYSTEM SnapNrack Residential PV Mounting Systems The SnapNrack line of solar mounting systems is designed to reduce total installation costs. The system features technical innovations proven on more than 300MW of solar projects to simplify the installation and reduce costs. - Pitched Roof Arrays Simplified The SnapNrack Series 100 UL Roof Mount System is an efficient, visually appealing, photovoltaic (PV) module installation system. Series 100 UL is listed to the UL 2703 Standard for Bonding, meaning that all system components have been certified by UL for electrical continuity, eliminating the need for additional Roof System in 4 Simple Steps: grounding hardware. The System's components provide 1) Go to the online Series 100 Configuration an adequate bonding path which has eliminated the Tool (configure.snapnrack.com) and select need for grounding lugs and washers at each module, "Yes" for UL 2703 Listed and bonding jumpers between splices. The UL 2703 2) Identify Site Conditions (Array Tilt, Building Certification ensures that SnapNrack partners can Height, Roof Type, Wind and Snow Loads) provide the best in class installations in quality, safety, and efficiency. 3) Build array in the online Configuration Tool and automatically generate a Bill of • All bonding hardware is fully integrated into the Materials. components 4) Place order with your distributor. Purchase • No grounding lugs required for modules material for a single project or order in bulk for additional savings • Rail splices bond rails together, no rail jumpers - Rail & Module Clamps required - Roof Attachments • Proprietary SnapNrack grounding lug snaps in the rail - Array Accessories channel, no drilling of rail or reaching for other tools required 43 Patent Pending LISTED PV Mounting System 2703 • Bondging Splice Insert Bonding Adjustable X-lir Splice Base End Clamp Top Bonding Mid Clamp "OW Bonding Adjustable X- 4.-- End Clamp Bottomft(Bonding Channel Nut SnapNrack Bonding Adjustable X-End Clamp SnapNrack Bonding \ SnapNrack Bonding J Mid Clamp Standard Rall Splice - - -- .. �� ---- - -- Bonding Channel Nut Bonding iktb Standoff Clamp _ L Foot Metal Roof Base Rubber Ali . Rain Collar • Bonding Channel Nut SnapNrack Metal Roof Base with Mill Finish I L Foot Bonding L Foot Standoff Mill Finish Standoff Base Bonding Universal End Clamp (1 Hole Base (UEC)Wave Shown) 4r UEC Pull Strap Mill Finish L Foot L Foot Base App, Flashing SnapNrack Bonding UEC Wedge Standoff Assembly _— SnapNrack Bonding L Foot Base with Flashing SnapNrack Bonding J Universal End Clamp SnapNrack Series 100 UL Technical Data Patent Pending Materials • 6000 Series aluminum • Stainless steel • Galvanized Steel Flashing Material Finish •Clear and black anodized aluminum •Mill Finish on select components Installation •Quick and efficient mounting •Adjustable hardware to ensure clean and level finish •All components bonded to ground with integrated bonding features Calcs. & Certifications • UL 2703 Certification • Stamped Structural Engineering Reports for all 50 States Grounding • SnapNrack Grounding Lug Warranty • 10 Year material and worksmanship (download full details at snapnrack.com) Snap rackTPA PV Mount (877) 732-2860 www.SnapNrack.com 0 Printed on recycled paper using soy based inks. ©2014 by SnapNrack PV Mounting System.All rights reserved. CERTIFICATE OF COMPLIANCE Certificate Number 20140204-E359313 Report Reference E359313-20140201 Issue Date 2014-FEBRUARY-04 Issued to: SNAPNRACK STE 200 775 FIERO LANE SAN LUIS OBISPO CA 93401 This is to certify that MOUNTING SYSTEMS, MOUNTING DEVICES, representative samples of CLAMPING DEVICES AND GROUND LUGS FOR USE WITH PHOTOVOLTAIC MODULES AND PANELS USL— Series 100 Mounting and Bonding Systems for use with Photovoltaic Modules Have been investigated by UL in accordance with the Standard(s) indicated on this Certificate. Standard(s)for Safety: UL Subject 2703-the Outline of Investigation for Mounting Systems, Mounting Devices, Clamping/Retention Devices, And Ground Lugs for use with Flat-Plate Photovoltaic Modules and Panels Additional Information: See the UL Online Certifications Directory at www.ul.com/database for additional information Only those products bearing the UL Listing Mark should be considered as being covered by UL's Listing and Follow-Up Service. The UL Listing Mark generally includes the following elements: the symbol UL in a circle: 0 with the word "LISTED"; a control number(may be alphanumeric) assigned by UL; and the product category name (product identifier) as indicated in the appropriate UL Directory. Look for the UL Listing Mark on the product. ),14 •r /J• C-/ William R.Camey,Director,North American Certification Programs UL LLC Any information and documentation involving UL Mark services are provided on behalf of UL LLC(UL)or any authorized licensee of UL.For questions,please contact a local UL Customer Service Representative at www.ul.coMcontactus Page 1 of 1 .1 LG Innovation for "" a Better Life LG N eO N' R 1.t,3soQ i I,. LG NeON®R is new powerful product with global top level performance.Applied new cell structure without electrodes 60 cell on the front,LG NeONe R maximized the utilization of light , ,,, and enhanced its reliability.LG NeONe R demonstrates LG's DVE C ® US C E c:71 efforts to increase customer's values beyond efficiency.ItRODUCT features enhanced warranty,durability,performance under real environment,and aesthetic design suitable for roofs. lit Enhanced WarrantyL It High Power Output LG now offer 25 years product warranty to accommodate The LG NeONe R has been designed to performance warranty as well.LG NeONe R has an significantly enhance its output making it efficient enhanced performance warranty.After 25 years,LG even in limited space. NeONe R is guaranteed at least 87.0%of initial performance. /� Aesthetic RoofOutstanding Durability LG NeONe R has been designed with aesthetics in With its newly reinforced frame design,LG mind:no electrode on the front that makes new 0NeONe R can endure a front load up to 6000 Pa, product more aesthetic.LG NeON®R can increase and a rear load up to 5400 Pa. the value of a property with its modern design. • LBetter Performance on a Sunny DayNear Zero LID (Light Induced Degradation) '..L LG NeON®R now performs better on a sunny The n-type cells used in LG NeON®R have days thanks to its improved temperature coefficient. almost no boron,which may cause the initial performance degradation,leading to less LID. About LG Electronics LG Electronics is a global player who has been committed to expanding its capacity,based on solar energy business as its future growth engine.We embarked on a solar energy source research program in 1985, supported by LG Group's rich experience in semi-conductor,LCD,chemistry,and materials industry.We successfully released first Mono Xe series to the market In 2010,which were exported to 32 countries in the following 2 years,thereafter.In 2013,NeONt"(previously known as Mono X*NeON)8 2015 Ne0N2 with CELLO technology won"Intersolar Award",which proved LG is the leader of innovation in the industry. LGN eO N " R LG350Q1C-A5 Mechanical Properties Electrical Properties(STC*) Cells 6 x 10 Module 350 Cell Vendor LG _ Maximum Power(Pmax) 350 Cell Type Monocrystalline/N-type MPP Voltage(Vmpp) 36.1 Cell Dimensions 161.7 x 161.7 mm/6 inches MPP Current(Impp) 9.70 Dimensions(L x W x H) 1700 x 1016 x 40 Inm Open Circuit Voltage(Voc) 42.7 66.93 x 40.0 x 1.57 inch Short Circuit Current(1st) 10.77 Front Load 6,000Pa/125 psf Module Efficiency 20.3 Rear Load 5,400Pa/113 psf Operating Temperature -40-+90 Weight 18.5 kg/40.79 lb Maximum System Voltage 1000 Connector Type MC4 Maximum Series Fuse Rating 20 Junction Box IP68 with 3 Bypass Diodes Power Tolerance(%) 0-+3 Length of Cables 1000 mm x 2 ea •STC(Standard Test Condition)Irradiance 1.000 W/m',Ambient I eniperatare 25°C,AM 1.5 Glass High Transmission Tempered Glass *The nameplate power output is measured and determined by L5 Electronics at its sole and absolute discretion. 'The typical change in module efficiency at 200 W/m'in relation to 1000 W/m'is-2.0%. Frame Anodized Aluminium Electrical Properties(NOCT*) Certifications and Warranty Module 350 Certifications IEC 61215,IEC 61730-1/-2 Maximum Power(Pmax) 264 UL 1703 MPP Voltage(Vmpp) 36.0 IEC 61701(Salt mist corrosion test) MPP Current(Impp) 7.32 IEC 62716(Ammonia corrosion test) Open Circuit Voltage(Voc) 40.1 ISO 9001 Short Circuit Current(1st) 8.67 Module Fire Performance(USA) Type 1 'NOCT(Nominal operating Cell Temperature)Irradiance 800 W/m.ambient temperature 20 C.wind speed 1 m/s Fire Resistance Class(CANADA) Class C(ULC/ORD C 1703) Product Warranty 25 years Output Warranty of Pmax Linear warranty** Dimensions(mm/in) •.i)FY.5 years 05%.2)After 5th year 0.4%annual degradation,3)25 yeas 67.0% Temperature Characteristics o NOCT 44±3°C Pmpp -0.30%/°C Voc -0.24%/°C !sc. 0.04%/°C Characteristic Curves Dnon w:u 1a G I2.W e°.ami. 10.00 Ti Ill e.0e a��wI6.G0 u.n.a.a°°n) 4,00_ 240_._ `.\ I \\I vMep.ly) 0,00 5.00 10.00 15.00 20.00 2500 30.00 35.00 40.00 45.00 ) t X 140 ix 120 3 M vo he .f 90 pur €.., , ill rildids.mum 20 ii 0 t_- T mparature(°C) .411 -25 0 25 5') 75 90 •The distance between the center of the mounting/grounding holes. ® LG North America Solar Business Team Product specifications are subject to change without notice.Wo LG Electronics U.S.A.Inc DS-T1.72- G-P-EN-60630 O r t� Life's Good 1000 Sylvan Ave,Englewood Cliffs,NJ 07632 `k.; ti 1 Copyright®2017 LG Electronics.All rights reserved. Innovation for a Better Life t Cialed Contact.Ig.solar@lge.com 01/01/2017 Afti�11 www.lgsolarusa.comEl •'r O. . VJ solar - • • 7 cc W ~ Phase Single Inverters CC For North America I I I SE3000A-US / SE3800A-US / SE5000A-US / SE6000A-US / SE7600A-US / SE10000A-US / SE11400A-US Z 11 1 1111' `Ar NA leattto :74 ,.73. Walla a itisi__ , bilio 4 t O.. • i 1 . , - The best choice for SolarEdge enabled systems Specifically designed to work with power optimizers — Superior efficiency(98%) Integrated arc fault protection and rapid shutdown for NEC 2014 and 2017, per article 690.11 and 690.12 — UL1741 SA certified,for CPUC Rule 21 grid compliance — Small, lightweight and easy to install outdoors or indoors on provided bracket — Built-in module-level monitoring — Internet connection through Ethernet or Wireless — Fixed voltage inverter for longer strings — Optional—revenue grade data,ANSI C12.1 USA-CANADA-GERMANY-ITALY-FRANCE-JAPAN-CHINA-AUSTRALIA-THE NETHERLANDS-UK-ISRAEL-TURKEY-SOUTH AFRICA-BULGARIA www.solaredge.us solar - . . z Single Phase Inverters for North America SE3000A-US/SE3800A-US/SE5000A-US/SE6000A-US/ SE7600A-US/SE10000A-US/SE11400A-US St1000A US SE3600A-US1 3E5000A-US SE6000A-USI SE7600A-US 5110000A-US I SE11400A-US -- OUTPUT 9980 @ 208V Nominal AC Power Output 3000 3800 5000 I 6000 I 7600 I I 11400 vA 10QQ0 N,J4 . 5406 @ 208V 10800 @ 208V "" Max.AC Power Output 3300 4150 6000 8350 12000 VA A4 Q.Q 44v I I 109500240 I AC Output Voltage Min.-Nom.-Max.m V _ _ 183-208-229 VacI AC Output Voltage Min:Nom.-Max.I') 211-240-264 Vac AC Frequency Min.-Nom:Max.(° I 59.3-60-60.5 Hi ilk Max.Continuous Output Current 12.5 16 I 24 2t3�V 25 I 32 I 48 'L08V I 47,5 A Al A MNI 44 A.0AY GFDI Threshold I 1 A Utillt Monitorin:,Islandln:Protection,Countr Conti;urable Thresholds Yes Yes -INPUT Maximum DC Power(STC) I 4050 I 5100 I 6750 1 8100 I 10250 I 13500 I 15350 W Transformer-less,Ungrounded Yes Max.Input Voltage I 500 I Vdc Nom.DC Input Voltage I 325 fp 208V/350 @ 240V I Vdc Max.Input Current(2) 9.5 I 13 116.5 @208V I 18 23 33 208V 34.5 Adc }5,5 A kW30.5.9.0RY Max.Input Short Circuit Current I 45 I Adc Reverse-Polarity Protection I Yes I Ground-Fault Isolation Detection I 600ku Sensitivity I Maximum Inverter Efficiency I 97.7 I 98.2 I 98.3 I 98.3 I 98 I 98 I 98 I % CEC Weighted Efficiency 97.5 I 98 1 97 @ 208V 1 37,5 I 37,3 I 97 @ 208V I 97.5 I % i$.e.24PY VA e.?4.QY Nighttime Power Consumption I <2.5 I <4 I W ADDITIONAL FEATURES Supported Communication Interfaces I RS485,RS232,Ethernet,ZlgBee(optional) I Revenue Grade Data,ANSI C12.1 I Optional") Rapid Shutdown-NEC 2014 and I Automatic Rapid Shutdown upon AC Grid Disconnect's) 2017 690,12 STANDARD COMPLIANCE Safety UL1741,UL1741 SA,UL1699B,CSA C22.2,Canadian AFC)according to T.I.L.M-07 I Grid Connection Standards I IEEE1547,Rule 21,Rule 14(HI) Emissions I FCC part15 class B I INSTALLATION SPECIFICATIONS AC output conduit size/AWG range I 3/4"minimum/16-6 AWG I 3/4"minimum/8-3 AWG DC input conduit size/8 of strings/ 3/4"minimum/1-3 strings/ 3/4"minimum/1-2 strings/16-6 AWG Ay/,CT ran6e P4-§Ayi/G Dimensions with SafetySwitch 30.5 x 12.5 x 7.2/775 x 315 x 184 30.5 x 12.5 x 10.5/ in .0.1xWxD) I 775 n 315.I<26Q nim Weight with Safety Switch I 51.2/23.2 I 54.7/24.7 I 88.4/40.1 I lb/kg Natural convection Cooling Natural Convection and internal Fans(user replaceable) fan(user 10141MVak!e1. Noise I <25 I <50 I dBA Min:Max.Operating Temperature -13 to+140/-25 to+60(-40 to+60 version available")) 'F/'C RePB@ Protection Rating I NEMA 3R I in For other regional settings please contact SolarEdge support. ni A higher current source may be used;the inverter will limit its input current to the values stated. IN Revenue grade inverter P/N:SExxxxA-US000NNR2(for 7600W Inverter:SE7600A-US002NNR2). IQ-40 version P/N:SExxxxA-U0000NNU4(for 7600W inverter:SE7600A-US002NNU4). l'i P/Ns SExxxxA-USoxxxxxx have Manual Rapid Shutdown for NEC 2014 compliance(NEC 2017 compliance with outdoor installation) • RoHS ©SolarEdge Technologies,Inc.All rights reserved.SOLAREDGE,the SolarEdge logo,OPTIMIZED BY SOLAREDGE are trademarks or registered trademarks of SolarEdge Technologies,Inc.All other trademarks mentioned herein are trademarks of their respective owners.Date:07/2017.V.01.Subject to change without notice. cc solar 1 N SolarEdge Power Optimizer 2 Module Add-On For North America F— P300 / P320 / P370 / P400 / P405 CL—' CDW O �`25Voa,g 9�' :. illipopt6tit\l, 11/ .1,/,,ii.. 3rtaatY W � O d•lY2�Wn ' / / - PV power optimization at the module-level - Up to 25%more energy - Superior efficiency(99.5%) - Mitigates all types of module mismatch losses,from manufacturing tolerance to partial shading - Flexible system design for maximum space utilization - Fast installation with a single bolt - Next generation maintenance with module-level monitoring - Module-level voltage shutdown for installer and firefighter safety USA•CANADA-GERMANY-ITALY-FRANCE-JAPAN-CHINA-AUSTRALIA-THE NETHERLANDS-UK-ISRAEL-TURKEY-SOUTH AFRICA-BULGARIA-INDIA www.solaredge.us so I a r " 6 • SolarEdge Power Optimizer Module Add-On for North America P300/ P320/ P370/ P400/ P405 P300 P320 (for h gherOpower P400 P405 (for 60-cell mod- (for high-power (for 72&96-cell (for thin film 60 and 72-cell ules) 60-cell modules) modules) modules) • modules) INPUT Rated Input DC Powerlrl 300 l 320 I 370 400 405 I w Absolute MaxImum Input Voltage 48 60 80 125 Vdc (Voc at lowest temperature) MPPT Operating Range 8-48 8-60 8-BO 12.5-105 I Vdc Maximum Short Circuit Current(lac) 10 I 11 10.1 I Adc Maximum DC Input Current 12.5 I 13.75 12.63 Adc Maximum Efficiency 99.5 ( % Weighted Efficiency I 98.8 I % Overvoltage Category I II OUTPUT DURING OPERATION(POWER OPTIMIZER CONNECTED TO OPERATING SOLAREDGE INVERTER) Maximum Output Current I 15 I Adc Maximum Output Voltage I 60 I 85 I Vdc OUTPUT DURING STANDBY(POWER OPTIMIZER DISCONNECTED FROM SOLAREDGE INVERTER OR SOLAREDGE INVERTER OFF) Safety Output Voltage per Power 1 Vdc Optimizer STANDARD COMPLIANCE EMC I FCC Part15 Class B,IEC61000-6-2,IEC61000-6-3 Safety IEC62109.1(class II safety),UL1741 RoHS I Yes INSTALLATION SPECIFICATIONS Maximum Allowed System Voltage 1000 Vdc Compatible inverters All SolarEdge Single Phase and Three Phase Inverters Dimensions(WxI.xH) 128x152x27,5/5x5.97x1.08 128x152x35/ 128x152x50/ mm/In 5x5.97x1.37 5x5.97 x1.96 Weight(,Including cables) I 630(1.4 I 750/1.7 845/1.9 gr/lb Input Connector MC4 Compatible Amphenol AH4 MC4 Compatible Double Insulated; Output Wire Type/Connector Double Insulated;MC4 Compatible MC4/ Double Insulated;MC4 Compatible Amphenol AH4 Output Wire Length 0.95/3.0 1.2/3.9 I m/ft Operating TemperatureRange -40-+85(-40-+185 I 'C/'F Protection Rating IP68/NEMA6P Relative Humidity 0-100 I % 1 l Rated STC power of the module.Module of up to♦5%power tolerance allowed. PV SYSTEM DESIGN USING SINGLE PHASE SINGLE PHASE THREE PHASE 208V THREE PHASE 480V A SOLAREDGE INVERTER000 HD-WAVE Minimum String Length I 8 10 18 ,(Power Optimizers) Maximum String Length I 25 25 50 (Power Optimizers) Maximum Power per String I 5700(6000 with I 5250 6000 ( 12750 1 w SE7600H-US) Parallel Strings of Different Lengths I Yes or Orientations Ol For debited string sizing Information refer to:http://www.solaredge.tom/sites/default/files/string sizing_na.pdf. W It Is not allowed to mix P405 with P300/P370/P400/P600/P700 In one string. CE Et1 ,1501,i,,,,,„technologies,Inc.All rights reserved.SOLARLOOt..the Solari rigs:Ingo,OPTIMIZED IP(SOLAREDGE are trademarks or registered trademarks of SolarEdge Technologies,Inc.All other trademarks mentioned herein are trademarks of their respective owners.Date:03/2017 V.02.Subject to change without notice.