Loading...
HomeMy WebLinkAboutSOLR-18-1677 '4 `11 a} F �ATlt 'k`‘t+!'1M=$ �+ •z -rr r+3 +,c"a t i a 9 _ City of Arcadia, CA ��`. +, -a''1 °` `�`PermitruO SOLR 18;,,1677 I Development Services Department '4 p_t +�k"''," �*t [i Perm(tT pe Sola?, ( x 240 West Huntington Drive,Post Office Box 60021 t $a g y (j - cJ x- I Arcadia,CA 91066-6021 a,- f,$ ..m..."1 i` %��1 A �,work ClpsslJrcaoon_SolarResldentlal (626)574-5416 '+.r - a+ V £ 7 z a x Permit Status Issued:: tr 'af- 1 i Ni n S .. 1T C-._4,. 1 r- ARCADIA a / / Expiration: 03/12/2019 Issue D'aTe D9 13 2018: Addr NO. Dir Prefix Street Name Street Suffix Unit City,State,Zip Parcel Number 2116 Canyon RD Arcadia,CA 5765010015 k Contacts BRAD BANTA Owner NOPEC INC* General Contractor(B) 2116 CANYON RD 530 S LAKE AVE 422,PASADENA,CA 91101 (626)826-752999 (626)793-6025 Description:ROOF MOUNTED SOLAR SYSTEM 52 PANELS. 9 Valuation: S 0,00 Tenant f iTotal Sq Feet: 0.00 Plan Check N Plan N Fees Amount r Payments Amount Paid Building Plan Check Fee Residential $50.00 Total Fees $300.91 Electrical Permit Issuance Fee $44.35 Cash/Receipt U REC-002299-2018 $300.91 Fire Plan Check Fee Residential $50.00 Inverters $77.78 Amount Due: $0.00 Panels $77.78 Solid Waste Management Fee 2 $1.00 Total: $300.91 p COMPETED ,_ ,t 1k,_ lo• Zq.re ?,--2--- CALLS FOR INSPECTIONS Request for inspection by telephone at 626-574-5450. Leave a message - requesting the address,timeframe and what inspection item is needed. This permit/plan review expires by time limitation and becomes null and void if the work authorized by the permit is not commenced within 180 days from the date of issuance or if the permit is not obtained within 180 days from the date of plan submittal.This permit expires and becomes null and void if any work authorized by this permit is suspended or abandoned for 180 consecutive days or if no progressive work has been verified by a City of Arcadia building inspector for a period of 180 consecutive days. September 13, 2018 Issued By: Date September 13,2018 Page 1 of 1. ,F A. 70 Olin S ® K PERMIT/PLAN REVIEW APPLICATION emii, Development Services Department,240 West Huntington Drive,Post Office Box 60021 Arcadia, CA 91066-6021, (626) 574-5416,Fax (626) 447-9173 City of Arcadia KLICENSED CONTRACTOR'S DECLARATION WORKERS'COMPENSATION DECLARATION J� I hereby affirm under penalty of perjury that I am licensed under provisions of I hereby affirm under penalty of perjury one of the following: Chapter 9(commencing with Section 7000,of Division 3 of the Business and IProfessions Code,and Signature of Contractor and my license is in full force and effect. ❑ I have and will maintain a certificate of consent to self-insure for workers' License Class .}9 /%Zg 7 Exp. Date T�)!� a compensation, as provided for by Section 3700 of the Labor Code, for the 111111 performance of the work for which this permit is issued. Elf OWNER-BUILDER DECLARATION tl`I have and will maintain workers'compensation insurance,as required by Section ❑ I hereby affirm under penalty of perjury that I am exempt from the Contractors 3700 of the Labor Code,for the performance of the work for which this permit License Law for the following reason(Section 7031.5,Business and Professions is issued.My workers'co�m^pensation insurance c e and policy numbers are: Code.Any city or county which requires a permit to construct,alter,improve, Carrier O LCMr2 Ci'l demolish,or repair any structure,prior to its issuance,also required the applicant C715-10(014 T�'...r'h. f for such permit to file a signed statement that he or she is licensed pursuant to the Policy Number ' V provisions of the Contractors License Law(Chapter 9(commencing with Section (This section need not be completed if the permit is for one hundred dollars or less) 7000)of Division 3 of the Business and Professions Code)or that he or she is exempt there from and the basis for the alleged exemption. Any violation of ❑ I certify that in the performance of the work for which this permit is issued,I shall Section 7031.5 by any applicant for a permit subjects the applicant to a civil not employ any person in any manner so as to become subject to the workers' penalty of not more than five hundred dollars($500)): compensation Laws of California,and agree that if I should become subject to the workers'compensation provisions of Section 3700 of the Labor Code,I shall 0 I, as owner of the property, or my employees with wages as their sole forthwith comply with hose provisions. compensation,will do the work,and the structure is not intended or offered for �/(3 �C/i � sale(Section 7044,Business and Professions Code:The Contractors License Date W Signature Law does not apply to an owner of property who builds or improves thereon, or who does such work himself or herself or through his or her own employees,provided that such improvements are not intended or offered for WARNING: Failure to secure Workers'Compensation coverage is unlawful, sale.If,however,the building or improvement is sold within one(1)year of and shall subject an employer to criminal penalties and civil fines up to one completion,the owner-builder will have the burden of proving that he or she hundred thousand dollars($100,000),in addition to the cost of compensation, did not build or improve for the purpose of sale). damages asprovided for in Section 3706 of the Labor Code, interest, and attorney's fees. ❑I, as owner of the property, am exclusively contracting with licensed contractors to construct the project(Section 7044,Business and.Professions Code:The Contractors License law does not apply to an owner of property CONSTRUCTION LENDING AGENCY who builds or improves thereon,and who contracts for such projects with a I hereby affirm under penalty of perjury that there is a construction lending agency contractor(s)licensed pursuant to the Contractors License Law). for the performance of the work for which this permit is issued (Section 3097, Civil Code). ❑ I am exempt under Section 7044,Business and Professions Code,for this reason: Lender's Name Date Signature Lender's Address IMPORTANT: APPLICATION IS HEREBY MADE TO THE BUILDING OFFICIAL FOR A PERMIT SUBJECT TO THE CONDITIONS AND RESTRICTIONS SET FORTH ON THIS APPLICATION AND THE FOLLOWING: 1. The City's approved plans and permit inspection card must remain on the job site for use by City inspection personnel. 2. Final inspection of the work authorized by this permit is required.A Certificate of Occupancy must be obtained prior to use and occupancy of new buildings and structures. 3. Per South Coast Air Quality Management District(AQMD)regulations,renovation and remodeling work that results in the removal,stripping,or altering of asbestos containing materials requires an asbestos survey and removal prior to disturbing the asbestos.Please contact AQMD at(909)396-2000 for further information. C 9,,f � arae U 'C1Ve 7e Title Pre OOr• 1 •_r • PRINT NAME I certify that I have read this application and state that the above information is correct and that I am the owner or duly authorized agent of the owner. I agree to comply with all City ordinances and State Laws relating to building construction. I hereby authorize representatives of the City of Arcadia to enter upon the above-mentioned property for inspection purposes. Q� ignamre 72(2-6—>�� V I Date COf i • Nese Driveway O c. . Allir Air Ilk* /1148, NO tree iessOFire Access Path from Driveway 200 A SeMce(E) •n least one pathway shall be provided _ on the street or driveway side of the roof: PV AC Disconnect w/Performance Meter(N) Solar Only AC Combiner(N) 0 0''- a O' 13 G BANTA HOME 17.42 kW SOLAR PV SYSTEM NOTES 2116 Canyon Road DESIGN DATE 1) Owner: Brad Banta Arcadia, CA 91006 PV 7124/2019 2) 17.42 kW PV System consisting of 52 LG 335 N1 C-A5 PV modules and 52 Enphase (626) 826-7529 IQ7PLUS-72-X-US(240 V)microinverters. SITE PLAN 3) The panels will be flush mounted on the southeast roof. - 4) Scale: NTS Nope;Inc D/B/A Run on Sun CA 530SLakeAve#47 Run on Sun®t 530 S Lake Ave#422 ` Pasadena CA 91101 628-793-6025 Designer.r S Clean Energyto Run Your Life" Pavey ' .c 4,Fozvvi i dj 1l ' 00 WcalC5:on"� AFFIDAVIT SELF-CERTIFICATION FOR COMPLIANCE OF SMOKE ALARMS AND CARBON MONOXIDE ALARMS Property Address: 2 11 tqN yo.J Permit Number: 50 L 2 - :8 -ito`7T) • Brief Job Description: sow- f/�'., Number of smoke alarms'installed: '�1 Number of carbon monoxidys lar s installed: 2_ When alterations, repairs or additions requiring a permit occur, or sleeping rooms are created, Smoke alarms shall be installed in each sleeping room, and outside each separate sleeping area in the immediate vicinity of the bedrooms, and on each additional story of the dwelling, including basements and habitable attics as required by Section R314 of the 2016 California Residential Code (CRC) and California Health and Safety Code Section 13113.7. For dwellings or sleeping units containing fuel burning appliances or having attached garages, carbon monoxide alarms shall be installed outside each . separate sleeping area in the immediate vicinity of the bedrooms, and on each additional story of the dwelling, including basements as required.by Section R315 of the of the 2016 California Residential Code (CRC). Multi-purpose alarms (combination carbon monoxide and smoke alarms) may be used. All alarms shall comply with requirements for listing and approval by the Office of the State Fire Marshal. http://osfm.fire.ca.aovllicensinglistinas/licenselistina bml searchcotest.pho As owner of the above referenced property, I hereby certify that the smoke alarms and carbon monoxide alarms have been installed in accordance with the manufacturer's instructions and in compliance with the code sections referenced above: I declare under penalty of perjury that the fore.oing is true and correct, and that this declaration was executed on (Date) ____ ,__ _ - __- = _- __ _ at Arcadia, California. Owner's Name (printed/typed: - ' 1. -Vl uv`Glia Signature of Owner: ) It(.-- / i �� This affidavit must be returned to th City of Arcadia inspector prior to final inspection SMOKE ALARM AND CARBON WIONCIME LARKLLQCA7iO_ Guest Room /a it Batttrou IStorage 11 Family Room 1111roallama Garage FIRST FLOOR PLAN •C SMOKE ALARM El iz CARBON MONOXIDE ALARM Mstr Bath Master Bedroom Dining Room Kitchen Bath Hull Close( "-° T., iCloscc tvlosct Family itootn ° ViiC Bedroom , Bedroom - SECOND FLOOR PLAN x SMOKE ALARM [a s CARBON 642064oXDOE ALARM