HomeMy WebLinkAboutUntitled ;. 4 `4 City of Arcadia, CA PermltNO SOLR 19 1737
° Development Services Department ` �. -.; ' ''�, c - 'irL w t Perm,t Type:Solar
240 West Huntington Drive,Post Office Box 60021 �t � a'3 r l ,. t-`
Arcadia,CA 91066-6021 ;�? f ; I -, Work Classlhcation Solar Residential
I - (626)574-5416 Permit Status:Issued
,
Af2CAb)IA IssueDatei08/29/2019{1 Expiration: 02/25/2020
Addr NO. Dir Prefix Street Name Street Suffix Unit City,State,Zip Parcel Number
1819 Anita Crest DR Arcadia,CA 5766006003
Contacts
RIMBENIEKS,EVALOS M AND JOAN R Owner SUNPOWER CORPORATION SYSTEMS* Contractor ,
1819 ANITA CREST DR 1414 Harbour WAY#1901,Richmond,CA
(408)218-6811 . ` 890895 s
Description:ROOF MOUNT PV SYSTEM, 16 MODULES/MICRO Valuation: $ 0,00 Tenant
INVERTERS/100 AMP LOAD CENTER ' .
9 Total Sq Feet: 0.00 Plan Check# Plan# ..
Fees Amount Payments Amount Paid
Building Plan Check Fee Residential $50.00 Total Fees $324.72
Distribution Panel $16.48 Cash/Receipt#REC-02321-19 $324.72
Electrical Permit Issuance Fee 547.01
Fire Plan Check Fee Residential 550.00 Amount Due: $0.00
Inverters $77.78
Panels $851.00
2.45 COP&ETEDwaste Management Fee 2 l
CALLS FOR INSPECTIONS
Request for inspection by telephone at 626-574-5450. Leave a message
requesting the addre ,timefram and h inspection item is needed.
7-/7-r7 s� 44 s C4/ feA0o1. y A
This permit/plan review expires by time limitation and becomes null and
void if the work authorized by the permit is not commenced within 180 days
from the date of issuance or if the permit is not obtained within 180 days
from the date of plan submittal.This permit expires and becomes null and
void if any work authorized by this permit is suspended or abandoned for 180
/� ///� consecutive days or if no progressive work has been verified by a City of
�t
-Z '—/1 /r ( 1C _ e l[ Arcadia building inspector for a period of 180 consecutive days.
1.
A.
August 29, 2019
Issued By: Date
August 29,2019 Page 1 of 1
W. 1 PERMIT/PLAN REVIEW APPLICATION
flop
lij Development Services Department, 240 West Huntington Drive,Post Office Box 60021
Arcadia, CA 91066-6021, (626) 574-5416,Fax (626)447-9173
City of
Arcadia
LICENSED CONTRACTOR'S DECLARATION WORKERS'COMPENSATION DECLARATION
❑ I hereby affirm under penalty of perjury that I am licensed under provisions of I hereby affirm under penalty of perjury one of the following:
Chapter 9(commencing with Section 7000,of Division 3 of the Business and
Professions Code,and my license is in fullllforce and effect. 0 I have and will maintain a certificate of consent to self-insure for workers'
License Class 00 License No.(jR"V-t-Exp. Date gl5 I compensation, as provided for by Sectioh 3700 of the Labor Code, for the
performance of the work for which this permit is issued.
Signature of Contractor
.- r 1r.:
OWNER-BUILDER DECLARATION I have and will maintain workers'compensation insurance,as required by Section
❑ I hereby affirm under penalty of perjury that I am exempt from the Contractors 3700 of the Labor Code,for the performance of the work for which this permit
License Law for the following reason(Section 7031.5,Business and Professions is issued.My workers'compensation insurance carrier and policy numbers are:
Code.Any city or county which requires a permit to construct,alter,improve, Carrier o -
demolish,or repair any structure,prior to its issuance,also required the applicant
Policy Number
for such permit to file a signed statement that he or she is licensed pursuant to the (This section need not be completed if the permit is for one hundred dollars or less)
provisions of the Contractors License Law(Chapter 9(commencing with Section
7000) of Division 3 of the Business and Professions Code)or that he or she is
exempt there from and the basis for the alleged exemption. Any violation of 0 I certify that in the performance of the work for which this permit is issued,I shall
Section 7031.5 by any applicant for a permit'subjects the applicant to a civil not employ any person in any manner so as to become subject to the workers'
penalty of not more than five hundred dollars($500)): compensation Laws of California,and agree that if I should become subject to the
workers'compensation provisions of Section 3700 of the Labor Code,I shall
❑I, as owner of the property, forthwith compl with those provisions.
or my employees with wages as their sole
compensation,will do the work,and the structure is not intended or offered for QlZi 9'
sale(Section 7044,Business and Professions Code:The Contractors License Date O [1 Signature
Law does not apply to an owner of property who builds or improves thereon,
or who does such work himself or herself or through his or her own
-
employees,provided that such improvements are not intended or offered for WARNING: Failure to secure Workers'Compensation coverage is'unlawful,
sale.If,however,the building or improvement is sold within one(1)year of and shall subject an employer to criminal penalties and civil fines up to one
completion,the owner-builder will have the burden of proving that he or she hundred thousand dollars($100,000),in addition to the costof compensation,
did not build or improve for the purpose of sale), damagesas provided for in Section-3706 of the Labor Code, interest, and
attorney's fees.
❑I, as owner of the property, am exclusively contracting with licensed -
contractors to construct the project(Section 7044,Business and Professions
Code:The Contractors License law does not apply to an owner of property CONSTRUCTION LENDING AGENCY
who builds or improves thereon,and who contracts for such projects with a I hereby affirm under penalty of perjury that there is a construction lending agency
contractor(s)licensed pursuant to the Contractors License Law). for the performance of the work for which this permit is issued (Section 3097,
Civil Code).
❑ I am exempt under Section 7044,Business and Professions Code,for this reason:
Lender's Name
Date Signature Lender's Address
IMPORTANT: APPLICATION IS HEREBY MADE TO THE BUILDING OFFICIAL FOR A PERMIT SUBJECT TO THE CONDITIONS AND
RESTRICTIONS SET FORTH ON THIS APPLICATION AND THE FOLLOWING:
1. The City's approved plans and permit inspection card must remain on the job site for use by City inspection personnel. !
2. Final inspection of the work authorized by this permit is required.A Certificate of Occupancy must be obtained prior to use and occupancy of new buildings
and structures.
3. Per South Coast Air Quality Management District(AQMD)regulations,renovation and remodeling work that results in the removal,stripping,or altering
of asbestos containing materials requires an asbestos survey and removal prior to disturbing the asbestos. Please contact AQMD at(909) 396-2000 for
further information. (I--
Name -iktcfrA, \a Title
PRINT NAME
I certify that I have read this application and state that the above information is correct and that I am the owner or duly authorized agent of the owner.
I agree to comply with all City ordinances and State Laws relating to building construction. I hereby authorize representatives of the City of
Arcadia to enter upon the above-mentioned property for inspection purposes. /{//� l
Signature a i /� Date R' `--- 1 /
� �y1FOq,���
Pa r 2\
,a%
0%allyiofiH°/e
AFFIDAVIT SELF-CERTIFICATION
FOR COMPLIANCE OF SMOKE ALARMS
AND CARBON/ MONOXIDE ALARMS
Property Address: l 219 Nv ko,_Ccrc �t- DC.—
Permit Number: 901R,—i`t4737 5-V.6‘..0)
``!!11� �c� t r
Brief Job Description: Rocs uy� cir �5`C M ( P�ekSv f�`CtirS ve
Number of smoke alarms installed:
Number of carbon monoxide alarms installed:
When alterations, repairs or additions requiring a permit occur, or sleeping rooms are created,
Smoke alarms shall be installed in each sleeping room, and outside each separate
sleeping area in the immediate vicinity of the bedrooms, and on each additional story of the
dwelling, including basements and habitable attics as required by Section R314 of the 2016
California Residential Code (CRC) and California Health and Safety Code Section 13113.7.
For dwellings or sleeping units containing fuel burning appliances or having attached
garages, carbon monoxide alarms shall be installed outside each separate sleeping
area in the immediate vicinity of the bedrooms, and on each additional story of the
dwelling, including basements as required by Section R315 of the of the 2016 California
Residential Code (CRC).
Multi-purpose alarms (combination carbon monoxide and smoke alarms) may be used.
All alarms shall comply with requirements for listing and approval by the Office of the State Fire
Marshal. http://osfm.fire.ca.qov/licensinolistings/licenselistinq bml searchcolest.php
As owner of the above referenced property, I hereby certify that the smoke alarms and carbon
monoxide alarms have been installed in accordance with the manufacturer's instructions and in
compliance with the code sections referenced above.
I declare under penalty of perjury that the/are oing is true and correct, and that this
declaration was executed on (Date) 17720/5 _ at Arcadia, California.
Ov War's Name (printed/typed): i� l /14N/i,✓
Signature of Owner:
This affidavit must be returned to the City of Arcadia inspector prior to final inspection
A ' •
- . i 1i 1• 1 1: '
. - I.
Ro
Guest Itoont '9atln'oun
IStorago
�r d�
iFtithily Boom _
1
ea
L._______ _ Garage
FIRST FLOOR FLAW
or. SMOKE ALARM a CARBON MONOXIDE ALARM
L ,fi , Msiraih
'
1 A Master Bedroom
Dining Room Kitchen
-13nt1:
0
Hall 0
Closet
E
I Clagei ;:-1 Closet
Fancily Room
C
Bedroom Bodoni
SECOND FLOOR PLAN
C) =SMOKE ALARM l E CARBON MONOXIDE ALARM
John Zurick
From: Alvin Waters Jr<Alvin.Waters@sunpower.com>
Sent: Monday, September 23, 2019 10:54 AM
To: Chi Leung; John Zurick
Cc: Nima Jalali; Heriberto Lora
Subject: Re: SOLR-19-1737-1819 Anita Crest Dr
Added correct email Jzurick@arcadiaca.gov
Get Outlook for iOS
From: Chi Leung<ChiFung.Leung@sunpowercorp.com>
Sent: Monday,September 23,2019 10:47:42 AM
To:Alvin Waters Jr<Alvin.Waters@sunpowercorp.com>;jzurick@arcadia.ca.gov<jzurick@arcadia.ca.gov>
Cc: Nima Jalali<NimaJalali@sunpowercorp.com>; Heriberto Lora<Heriberto.Lora@sunpowercorp.com>
Subject: RE:SOLR-19-1737-1819 Anita Crest Dr
Hi Mr Zurick,
30A breaker is properly sized for the PV system output in compliance with NEC 210.19(A) and 705.12(D)(2)(3)(b).
Total current output from the 2 branches of PV=23.2A,with 125%factor for continuous output per NEC 210.19(A) =
29A. Next size up breaker=30A.
The 15A/2P breaker is responsible for the PV monitor system,PVS6,which isn't part of the PV output. It shall not be in
part of PV over-current protection and wire sizing as it's technically a load, not addition to the PV system output.
AWG#10 wire is also the proper wire size for 30A circuit per NEC 240.4(D),and 310.15(B)(2)(b)with temperature derate
factor.
Should you have any additional questions, please feel free to reach out to me with contact provided below.
Thanks,
-Chi. •
Chi Fung Leung, P.E. Residential Project Engineer
77 Rio Robles,San Jose, CA 95134 j mobile+1.510.712.0824 I chifung.leung@sunoower.com
SUNPOWER®
From:Alvin Waters Jr
Sent: Monday,September 23, 2019 7:48 AM
To:jzurick@arcadia.ca.gov
Cc: Nima Jalali<Nimajalali@sunpowercorp.com>; Heriberto Lora<Heriberto.Lora@sunpowercorp.com>;Chi Leung
<ChiFung.Leung@sunpowerco rp.com>
Subject: RE:SOLR-19-1737- 1819 Anita Crest Dr
Chi+
Please see below email. Can you please assist on the project for homeowner Joan Rimbenieks?. Mr Zurick requested
clarification from an Electrical Engineer pertaining to our backfeed that it is the correct according to California's standard
PV requirements. This is necessary for us to get our permit finaled. Kindly advise at your convenience.
1
Alvin Waters I Permit CoordinatoriSan Fernando Valley I SPRI
Alvin.Waters@sunpowercorp.com I Cell: (818)-497-5571
SUNPOWER
From:Alvin Waters Jr
Sent:Thursday,September 19,2019 8:59 AM
To:jzurick@arcadia.com
Cc: Nima Jalali<Nima.Jalali@sunoowercorp.com>; Heriberto Lora<Heriberto.Lora@sunpowercorp.com>
Subject:SOLR-19-1737-1819 Anita Crest Dr
Hi John,
I'm reaching out to correspond to an inspection correction at this project address for our roofmount solar for our
inspection which was held yesterday September 19,2019.
I was advised by our Inspection Coordinator Heriberto Lora who walked the inspection with you that there was a
concern about our PV Backfeed of our amps being too much load in addition that we are back feeding too many amps to
our service panel.
Pertaining to your concern on our PV backfeed we are and always have designed our plans to comply with the point of
connection in section 705.12(1)(a)where we are not exceeding the 125%rule. Our backfeed is the maximum at 40A
which we can't exceed and we are not. Please see my calculation referenced from our branch circuits.
15(Number of Panels)x 1.25 (125%)x 1.45(Maximum continues Output)=29 the next size up for our backfeed is 30A. 1
In addition the 30A is based on our temperature derate coefficient of.58 and our derating coefficient of.80. Please
reference our electrical calculations and the following tables listed.
Table 310.15(B)(2)(a)
Table 310.1S(B)(16)
•
Pertaining to our branch circuits please review our AC Module information which shows our maximum branch circuits at
"20A"which is highlighted and please also refer to the UL number on our sheet.
The two branch circuits for 20A is only pertaining to the number of AC modules and microinverters in the branch circuit
where the 15A is which is the MLO is the Main Lug Out to backfeed to our 30A. We are technically following California's
requirement for solar standard under Title 24. Also keep in mind this is not a central inverter system.
Please forward this correspondence to your electrical engineer for further review and reach out with further questions.
''�eqa°
Alvin Waters I Permit CoordinatoriSan Fernando Valley I SPRI
Alvin.Waters@sunpowercorp.com I Cell: (818)-497-5571
SUNPOWER
2
PdIWERTM
8/28/2019
Attn.: To Whom It May Concern
re: Job JOAN RIMBENIEKS: 1819 ANITA CREST DRIVE, ARCADIA, CALIFORNIA 91006
The following calculations are for the structural engineering design of the photovoltaic
panels.
After review, I certify that the roof structure has sufficient structural capacity for the
applied PV loads.
All PV mounting equipment shall be designed and installed per manufacturer's approved
installation specifications.
03C ESS10N
If you have any questions, don't hesitate to contact. F
ktQ y��c2
C 84486
Sincerely, * Exp, 09/30/2021 *
Ali Hajihashemi, PE `,,q C1V1t
9/
Design Criteria:
Code: 2016 California Building Code
ASCE 7-10
Live Load: 20 psf
Ult Wind Speed: 110 mph
Exposure Cat: B
Ground Snow: 0 psf
2125 E Katella Ave#220,Anaheim, CA 92806 1714.787.3850
Date :8/28/2019
Job Code:JOAN RIMBENIEKS
SUNPOW E2 °f7
Structrure Geometry:
Mean Roof Height, hn = 13 ft
Eave Height, he = 8 ft
Buiding Length, L = 50 ft
Building Width, B = 30 ft
Module Area = 17.5 ft2
Roof Properties:
Roof 1 Roof 2
Roof Pitch (deg) = 21 21
Roofing Type = Comp Shingle Comp Shingle
Sheathing Type = 5/8 OSB Sheathing 5/8 OSB Sheathing
Wood Species= Doug Fir-Larch#2 Doug Fir-Larch#2
Wood Fb (psf) = 129600 129600
Wood Fv(psf) = 25920 25920
Wood E (psf) = 230400000 230400000
Wood Lag Withdrawal (lb/in) = 266 266
Framing Type= 2x6 Rafter 2x6 Rafter
Framing OC Spacing(in.) = 24 24
Section Thickness, b (in.) = 1.50 1.50
Section Depth, d (in.) = 5.50 5.50
Section Modulus, Sx (in.^3) = 7.56 7.56
Beam Span (ft) = 8 10
Pen Trib Width (ft) = 2.55 2.55
Rail Span (ft) = 6.00 6.00
CD (Wind) = 1.6 1.6
CD (Snow) = 1.15 1.15
Cis= 1.15 1.15
CM = 1.0 1.0
Ct= 1.0 1.0
CL= 1.0 1.0
CF= 1.3 1.3
Cfu= 1.0 1.0
Ci= 1.0 1.0
= 1.15 1.15
Malowable_Wind(lb-ft) = 1560 1560
Mallowable snow (lb-ft) = 1121 1121
2125 E Katella Ave #220,Anaheim, CA 92806 1714.787.3850
Date :8/28/2019
Job Code:JOAN RIMBENIEKS
S U N P SIV E RT' 3 of 7
Dead Load:
Comp Shingle 3.0
5/8 OSB Sheathing 2.0
2x6 Rafter @ 24" OC 0.9
Misc(Insulation etc) 1.0
Total Roof 1 DL 6.9 psf
Comp Shingle 3.0
5/8 OSB Sheathing 2.0
2x6 Rafter @ 24" OC 0.9
Misc(Insulation etc) 1.0
Total Roof 2 DL 6.9 psf
PV DL 2.8 psf
Roof 1 Roof 2
Roof_Dist_DL= 13 13
M_Roof_Dist_DL= 104 162
Def Roof Dist DL= 0.0030 0.0073
PV_uni Dist_DL= 5 5
M_PV_uni Dist_DL= 42 66
Def_PV_uni_Dist DL= 0.0012 0.0030
Total_uni DL= 18 18
M_Total_uni_DL 146 228
Def Total uni DL= 0.0042 0.0103
Rail_Down_DL= 7 7
Rail_M_DL= 54 54
Pens_Down_DL= 54 54
Pens Side DL= 21 21
Wind Load:
Ultimate Wind Speed = 110 mph
2125 E Katella Ave#220,Anaheim, CA 92806 ( 714.787.3850
Date :8/28/2019
Job Code:JOAN RIMBENIEKS
SUNP � ) 1NERT'" 4of7
Directionality Factor, kd = 0.85
Topographic Factor, kzt= 1
Velocity Pressure Exposure Factor, kz= 0.70
Velocity Pressure, qz= 18.45
Roof 1 Roof 2
External Pressure Up, GCp_1= -0.85 -0.85
External Pressure Up, GCp_2= -1.55 -1.55
External Pressure Up, GCp_3 = -2.45 -2.45
External Pressure Down, GCp = 0.45 0.45
Design Pressure Up, p_1= -15.68 -15.68
Design Pressure Up, p_2= -28.59 -28.59
Design Pressure Up, p_3 = -45.19 -45.19
Design Pressure Down, p= 16.00 16.00
uni_Dist_W_up= -31 -31
M_uni_Dist_W_up= -251 -392
Def uni_Dist_W_up= -0.0072 -0.0177
uni_Dist_W_down= 32 32
M_uni_Dist_W_down= 256 400
Def uni Dist Wdown = 0.0074 0.0180
Module_Up_W1= -16 -16
Module_Up_W2= -29 -29
Module Down W= 16 16
Rail_Up_W1= -40 -40
Rail_Up_W2= -73 -73
Rail_Down_W= 41 41
Rail_M_Up_W1= -320 -320
Rail_M_Up_W2= -584 -584
Rail M Down W= 327 327
Pens_Up_W1= -320 -320
Pens_Up_W2= -584 -584
Pens Down W= 327 327
Module Check (Service Level):
2125 E Katella Ave#220,Anaheim, CA 92806 1714.787.3850
Date :8/28/2019
Job Code:JOAN RIMBENIEKS
SUMP W E RTM 5 of 7
Roof 1 Down = 16 psf < 125 psf OK
Roof 1 Up zl = 16 psf < 62 psf OK
Roof 2 Down = 16 psf < 125 psf OK
Roof 2 Up z1 = 16 psf < 62 psf OK
Rail Check (LRFD):
Roof1 1.4D : 75 lb-ft < 548 lb-ft OK
Roof1 1.2D+ 1.6S+0.5W : 228 lb-ft < 548 lb-ft OK
Roof1 1.2D+0.55+ 1.0W : 391 lb-ft < 548 lb-ft OK
Roof1 0.9D + 1.0W(Up z1) : 272 lb-ft < 580 lb-ft OK
Roof2 1.4D : 75 lb-ft < 548 lb-ft OK
Roof2 1.2D+ 1.65 +0.5W : 228 lb-ft < 548 lb-ft OK
Roof2 1.2D +0.55 + 1.0W : 391 lb-ft < 548 lb-ft OK
Roof2 0.9D + 1.0W (Up z1) : 272 lb-ft < 580 lb-ft OK
Attachment Check (ASD):
Roof1 1.0D +0.6W : 250 lbs < 1254 lbs OK
Roof1 1.0D +0.75*[1.05+0.6W] : 201 lbs < 1254 lbs OK
Roof' 1.OD +1.05 : 54 lbs < 1254 lbs OK
Roof1 0.6D+0.6W (Up z1) : 160 lbs < 1254 lbs OK
Roof2 1.OD+0.6W : 250 lbs < 1254 lbs OK
Roof2 1.OD+0.75*[1.05+0.6W] : 201 lbs < 1254 lbs OK
Roof2 1.0D + 1.05 : 54 lbs < 1254 lbs OK
Roof2 0.6D + 0.6W (Up z1) : 160 lbs < 1254 lbs OK
Attachment Lateral Check(ASD):
Roof1 1.0D + 1.05 : 21 lbs < 1536 lbs OK
Roof2 1.OD+ 1.05 : 21 lbs < 1536 lbs OK
Lag Screw Uplift Check(ASD):
2125 E Katella Ave#220,Anaheim, CA 92806 1714.787.3850
Date :8/28/2019
Job Code:JOAN RIMBENIEKS
S U M P VIS' E RTM 6 of 7
5/16" Lag Screw Withdrawl Value = 266 lbs
Lag Screw Penetration = 2.5 in.
Roof'0.6D+0.6W (Up z1) : 160 lbs < 665 lbs OK
Roof2 0.6D+0.6W (Up zl) : 160 lbs < 665 lbs OK
Framing Check(ASD):
Roof1 uni 1.OD +0.6W : 299 lb-ft < 1560 lb-ft OK
Roofluni 1.OD+0.75*[1.05+0.6W] : 261 lb-ft < 1560 lb-ft OK
Roof' uni 1.OD+ 1.05 : 146 lb-ft < 1121 lb-ft OK
Roof' uni 0.6D +0.6W (Up z1) : 63 lb-ft < 1560 lb-ft OK
Roof2 uni 1.OD +0.6W : 468 lb-ft < 1560 lb-ft OK
Roof2 uni 1.OD +0.75*[1.05 +0.6W] : 408 lb-ft < 1560 lb-ft OK
Roof2 uni 1.OD + 1.0S : 228 lb-ft < 1121 lb-ft OK
Roof2 uni 0.6D +0.6W (Up z1) : 99 lb-ft < 1560 lb-ft OK
Seismic Check:
Stucco 10.0 psf
2x4 Studs @ 16" 2.0 psf
Gypsum 3.0 psf
Misc. (Insulation, etc.) 2.0 psf
Total Wall DL= 17 psf
Total Wall Area = 1280 ft^2
Total Wall W= 21760 lbs Existing Weight
Total Roof DL= 7 psf
Total Roof Area = 1500 ft^2
Total Roof W= 10418 lbs Existing Weight
PV Panel W= 46 lbs
Number of Panels = 16
Total PV W= 728 lbs Additional Weight
%increase= (Wexisting+Wadditional)/Wexisting = 2% OK
2125 E Katella Ave#220,Anaheim, CA 92806 1714.787.3850
Date :8/28/2019
Job Code:JOAN RIMBENIEKS
S U N P W E RTM 7 of 7
The increase in weight as a result of the solar system is less than 10% of the existing structure and therefore no
further seismic analysis is required.
Limits of Scope of Work and Liability
The calculations produced for this dwelling's assessment are only for the proposed solar panel installation
referenced in the stamped plan set and were made according to generally recognized structural anlaysis standards
and procedures.