Loading...
HomeMy WebLinkAboutUntitled City of Arcadia, CA - = Permit NO.SOLR-19-1650 1 i 47.- : t Development Services Department t v x> , -_ Permit Type;Solar 240 West Hundn ton Drive,Post Office Box 60021 \Jf i' +- f` � E work Classification Solar Residential. .)...).___,_ Arcadia,CA 91066-6021 .,�,, � (626)574-5416 - -- PermitStatus: ARCADIA ism:eoate:09/04/20191 Expiration: 03/02/2020 Addr NO. Dir Prefix Street Name Street Suffix Unit City,State,Zip Parcel Number 1627 Oakhaven DR Arcadia,CA 5766022014 Contacts GUGGILAM SRESTY Owner True Power Solar Contractor 1627 OAKHAVEN DR 201 Clark AVE,Pomona,CA 91767 (714)676-8888 970591 Description:ROOF MOUNTED SOLAR SYSTEM 22 MODULES 1 & Valuation: $ 0.00 Tenant INVERTER.200 AMP SERVICE UPGRADE Total Sq Feet: 0.00 Plan Check It Plan# Fees Amount I Payments Amount Paid Building Plan Check Fee Residential $50.00 Total Fees $324.72 Electrical Permit Issuance Fee $47.01 Cash/Receipt#REC-02362-19 $324.72 Fire Plan Check Fee Residential $50.00 Inverters $77.78 Amount Due: $0.00 Panels $82.45 Residential Services up to 400 amps $16.48 Solid Waste Management Fee 2 $1.00 ������,„��i{ cOJ1I3gEn Total: $324.72 tG� 3o' / 9 CALLS FOR INSPECTIONS �I ni.4-(_ /' Request for inspection by telephone at 626-574-5450. Leave a message requesting the address,timeframe and what inspection item is needed. This permit/plan review expires by time limitation and becomes null and void if the work authorized by the permit is not commenced within 180 days from the date of issuance or if the permit is not obtained within 180 days from the date of plan submittal.This permit expires and becomes null and void if any work authorized by this permit is suspended or abandoned for 180 consecutive days or if no progressive work has been verified by a City of Arcadia building inspector for a period of 180 consecutive days. September 04, 2019 Issued By: Date September 04,2019 Page 1 of 1 PERMIT/PLAN REVIEW APPLICATION tits , 41: Development Services Department,240 West Huntington Drive,Post Office Box 60021 Arcadia, CA 91066-6021, (626) 574-5416,Fax (626) 447-9173 City of Arcadia LICENSED CONTRACTOR'S DECLARATION WORKERS'COMPENSATION DECLARATION ❑ I hereby affirm under penalty of perjury that I am licensed under provisions of I hereby affirm under penalty of perjury one of the following: Chapter 9(commencing with Section 7000,of Division 3 of the Business and Professions Coca ,nild my 1' ense is in fu o e and effect. 0 I have and will maintain a certificate of consent to self-insure for workers' License Class t nse No. 0-5Z7 Exp. Dat12- 3(I Signature of Contractor \ 0' compensation, as provided for by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. OWNER-BUILDER D ARATION have and will maintain workers'compensation insurance,as required by Section ❑ I hereby affirm under penal . perjury that I am exempt from the Contractors 700 of the Labor Code,for the performance of the work for which this permit License Law for the following :. on(Section 7031.5,Business and Professions is issued.My orke1rs'compensation insurance carrier and policy numbers are: Code.Any city or county which requires a permit to construct,alter,improve, Carrier L.S.- demolish,or repair any structure,prior to its issuance,also required the applicant l (Li 7 0.54-L40 for such permit to file a signed statement that he or she is licensed pursuant to the Policy Number l provisions of the Contractors License Law(Chapter 9(commencing with Section (This section need not be completed if the permit is for one hundred dollars or less) 7000)of Division 3 of the Business and Professions Code) or that he or she is exempt there from and the basis for the alleged exemption. Any violation of ❑ I certify that in the performance of the work for which this pennit is issued,I shall Section 70315 by any applicant for a permit subjects the applicant to a civil not employ any person in any manner so as to become subject to the workers' penalty of not more than five hundred dollars($500)): compensation Laws of California,and agree at if I should become subject to the workers'compensation provisions of Se ' 3700 of the Labor Code,I shall ❑I, as owner of the property, fonhwi coTy with those provisions. or my employees with wages as their sole compensation,will do the work,and the structure is not intended or offered for sale(Section 7044,Business and Professions Code:The Contractors License Date Signature Law does not apply to an owner of property who builds or improves thereon, or who does such work himself or herself or through his or her own employees,provided that such improvements are not intended or offered for WARNING: Failure to secure Workers'Compensation coverage is unlawful, sale.If,however,the building or improvement is sold within one(1)year of and shall subject an employer to criminal penalties and civil fines up to one completion,the owner-builder will have the burden of proving that he or she hundred thousand dollars($100,000),in addition to the cost of compensation, did not build or improve for the purpose of sale). damages as provided for in Section 3706 of the Labor Code, interest, and attorney's fees. ❑I, as owner of the property, am exclusively contracting with licensed contractors to construct the project(Section 7044,Business and Professions Code:The Contractors License Law does not apply to an owner of property CONSTRUCTION LENDING AGENCY who builds or improves thereon,and who contracts for such projects with a I hereby affirm under penalty of perjury that there is a construction lending agency contractor(s)licensed pursuant to the Contractors License Law). for the performance of the work for which this permit is issued (Section 3097, Civil Code). U I am exempt under Section 7044,Business and Professions Code,for this reason: Lender's Name Date Signature _ Lender's Address IMPORTANT: APPLICATION IS HEREBY MADE TO THE BUILDING OFFICIAL FOR A PERMIT SUBJECT TO THE CONDITIONS AND RESTRICTIONS SET FORTH ON THIS APPLICATION AND THE FOLLOWING: 1. The City's approved plans and permit inspection card must remain on the job site for use by City inspection personnel. 2. Final inspection of the work authorized by this permit is required.A Certificate of Occupancy must be obtained prior to use and occupancy of new buildings and structures. 3. Per South Coast Air Quality Management District(AQMD)regulations,renovation and remodeling work that results in the removal,stripping,or altering of asbestos containing materials requires an asbestos survey and removal prior to disturbing the asbestos.Please contact AQMD at(909)396-2000 for Ifurther( information. (\I Name `l J� 1 ,t_ " 1\ 41.014"4-11 ---- \itle / PRINT NAME I certify that I have read t it : ,plication and state that the above information is correct and that I am the owner or duly authorized agent of the owner. I agree to comply with . C' ordinances and State Laws relating to building construction. I hereby authorize representatives of the City of Arcadia to enter upon 'e abo •-mentioned property for inspection purposes. Si nature \Date / 14- 1 i 9 i LP.1F011 �°$T� f \1 AFFIDAVIT SELF-CERTIFICATION FOR COMPLIANCE OF SMOKE ALARMS AND CARBON MONOXIDE ALARMS Property Address: I Co 217 nide OAUerj/(L Permit Number: /°/' /Corp Brief Job Description: i°V S7s-Try1 Number of smoke alarms installed:. Number of carbon monoxide alarms installed: I When alterations, repairs or additions requiring a permit occur, or sleeping rooms are created, Smoke alarms shall be installed in each sleeping room, and outside each separate sleeping area in the immediate vicinity of the bedrooms, and on each additional story of the dwelling, including basements and habitable attics as required by Section R314 of the 2016 California Residential Code (CRC) and California Health and Safety Code Section 13113.7. For dwellings or sleeping units containing fuel burning appliances or having attached garages, carbon monoxide alarms shall be installed outside each separate sleeping area in the immediate vicinity of the bedrooms, and on each additional story of the dwelling, including basements as required by Section R315 of the of the 2016 California Residential Code (CRC). Multi-purpose alarms (combination carbon monoxide and smoke alarms) may be used. All alarms shall comply with requirements for listing and approval by the Office of the State Fire Marshal. http://osfm.fire.ca.qov/licensinalistinas/licenselistinq bml searchcotest.php As owner of the above referenced property, I hereby certify that the smoke alarms and carbon monoxide alarms have been installed in accordance with the manufacturer's instructions and in compliance with the code sections referenced above. I declare under penalty of perjury that the foregoing is true and correct, and that this declaration was executed on (Date)� gel/• 3° i 2 fl/ 7 1 at Arcadia, California. / Owner's Name (printed/typed • C u,9 S) Ium � -5_7`f Signature of Owner: • This affidavit must be returned to the City of Arcadia inspector prior to final inspection S'.'O E r,L„R`I •`,FI• C •,'y 'Os,OXIDE �. •CATIO• ,: Guest Room _ �` i3athroo IStorage I I Family Room r s Garage ® FIRST FLOOR PLAN 410= SMOKE ALARM = CARBON MONOXIDE ALARM Mstr L Daly • - r, Master Bedroom Dining Room Kitelien -Batts Nall a u Closet �- I Closet Closet Family Room =, C Bedroonm Bedroom SECOND FLOOR PLAN S SMOKE ALARM 111 e CARBON MONOXIDE ALARM , APOLLO 4050 E.ARROW HWY.STE.A7 STRUCTURAL MONTCLAIR,CA 91703 Structural Calculations for: Guggilam Sresty Residence 8.47 kW DC Photovoltaic Array Addition 1627 Oakhaven Dr. Arcadia, CA 91006 Owner/Developer: True Power Solar 201 Clark Ave. • Pomona, CA 91767 August 23, 2019 Job#: 19-2051 d�oQoopQ4i. �cdokofEss IO IQ Y .�1 10 oc~. a a - A � V t�� �% N..C75.95aan �0 EXP.�•'0 0`1,404 k4Q OF CM. 1 of 4 A P D L L U 4650 E.ARROW HWY.STE.Al STRl1ETI1RAL MONTCLAIR.CA 91763 f SOLAR RESIDENTIAL ROOF/BUILDING CHECK Check Photovoltaic Array Addition-2016 California Building Code(CBC) Gravity Design Loads: Roof Type: Flat concrete tile over 1/2"sheathing over rafters over 5/8"gypsum board Live Load: 20.0 psf Dead Load: Roofing Material: 12.0 psf Sheathing: 1.5 psf Roof Framing Members: 2.5 psf • Drywall: 1.5 psf Insulation: 1.0 psf Miscellaneous: '1.5 psf Solar Array&Rack System 2.98 psf —Additional Load Applied Roof Dead Load w/o Solar Array= 20.00 psf Over<50%of Roof Area Roof Dead Load at Solar Array= 22:98 psf • Total Roof Load w/o Solar Array= 40.0 psf • Total Roof Load at Solar Array= 43.0 psf Area of Solar Array Addition(for gravity check)= 462 ft2 Total Area of Affected Rafters(for gravity check)= 3000 ft2 Area of Solar Array Addition(for seismic check)_ 462 fta Total Area of Affected Roof(for seismic check)= 3000 ft= Check Additional Gravity Loads on Rafters: Total Load Increase at Affected Rafters= 0.46 psf %of Total Load Increase= 1.15% < 5.0% OK Per CBC 3403A.3 Additional Solar Array Weight is Structurally Acceptable Check Additional Gravity Loads on Lateral Resisting System: Dead Load Increase at Entire Roof= 0.46 psf %Dead Load Increase on Entire Roof= 2.29% < 10.0% OK Per CBC 3403A.4 Additional Solar Array Lateral Load is Structural ` Acceptable 2 of4 Sht: El A P O L L O 4650 E. ARROW HWY. STE. A7 Date: STRUCTURAL MONTCLAIR. GA 91763 n. _ ROOF MOUNTED SOLAR PANELS 1 L_ Earthquake Design per ASCE 7-16-13.3.1 I Design Parameters Site Class= D Per Table 16134.3.2 Latitude,deg Longitude,deg Short Period S.A.,5,= 1.991 2015 NEHRP Provisions 34.1605 -118.0361 Site Coefficient,F,= 1.20 Table 1613A.3.3(1) Sms=F,S,= 2.39 EQ 16A-37 Sos=2/3 Sms= 1.59 EQ 16A-39 importance Factor,IP= 1.00 Section 13.1.3 Height of Equipment,z= 12.00 ft Height of Roof,h= 12.00 ft Weight of Panels to each Mount,Wp= 50.70 lbs 4.p= 1.00 Table 13.6-1 Rp= 2.50 Table 13.6-1 Determine Fp.Seismic Design Force(STRENGTH LEVEL} Fp=(0.4ap$psWp)(1+2z/h)/(Rdlp)= 39 lbs EQ13.3-1 [Not Greater Than:] Fp=1.6SpsWplp= 129 lbs EQ13.3-2 .[Not Less Than:] Fp=0.35psWpIp= 24 lbs EQ 13.3-3 Use Fp= 39 lbs at each Roof Mount Bracket • 3 of 4 Sht: Wt A P 0 L L 0 4050 E.ARROW HWY, STE.A7 Date: _ STRUCTURAL MONTCLAIR,CA 817fi3 A _ L ROOF MOUNTED SOLAR PANELS- MAIN HOUSE (WORST CASE) Components and Cladding-WindLoad Design per ASCE 7-16,30.4.2-h<60 ft Design Parameters Design Wind Velocity(35 Gust),V= 110 mph Wind Exposure= C Mean Panel Height= 12.00 ft Total Effective Area of Typical Array= 462 ft2 Panel Area to Each Support= 21.00 ft2 Angle of Panels= 18 degrees a= 3 ft(3ft.Min.) Determine Wind Force at Each Roof Mount qh=0.00256 K,Kn Kd V2I= 13.4 psf Load case 0.6•gh K,= 0.85 Table 30.3-1,Page 317 Kn= 1.0 Figure 26.8-1,Page 252-253 Kd= 0.85 Table 26.6-1,Page 250 1= LOD Internal Pressure Coeff.=GCPI= 0 +/-(Figure 6-5) v=O' .1 GCP(Zone 1)= 0.45 -0.85 Per Figures 30.4-1 thru 30.4-7 GCp(Zone 2)= 0.45 -1.60 Per Figures 30.4-1 thru 30A-7 GC,(Zone 3)= 0.45 -1.60 NO PANELS IN ZONE 3 (+)P=qh(GCP.-GC0)= 10.0 -21.5 psf,Positive Wind(10 psf min)-Worst Case Lateral Load at Each Mount= 65 -139 lbs Compression/Uplift at Each Mount= 200 -429 lbs Roof Mount is attached to roof sheathing&roof members w/(1)5/16"x 3-1/2"Lag Bolt w/Min.2.5"thread embed per TRUE POWER SOLAR. Allowable Loads for 5/16" Diameter Lag Screw per the 2015 NDS: (Table 11.2A) Wlthdrawi= 266 lb/in x 2.5"embed x (Cd=1.6)= 1064 lbs (Table 11K) Shear= 120 lb x (Cd=1.6) = 192 lbs SOLAR ARRAY ATTACHMENT METHOD IS STRUCTURALLY ACCEPTABLE. 4 of 4 PHOTOVOLTAIC ARRAY ..... (22)Hanwha Q.PEAK 385Watt Solar Modules(Q.PEAK DUO L-G5.3 385W) (1)Solar Edge 7.6KW Inverter(5E7600H-US) ROOF PLAN (22)P400 Power Optimizers UNIT INDEX Drawn w'"'�A MSP (N)200A Main SerWce Panel Solar Army I III INV (N)Solar Edge 7.6 KW Inverter 4 Hanwha 0 Peak 385W ACD (N)60A Non-Fused AC Disconnect 4 P40 Pitch: 8 Deg a D Pittlr:lB Deg O JIB (N)Nema 3R Junction Box Orientation:270 De. a ❑ 1=I Solar Module with (O,: - - PowerOptimizera 0 A. EMT type conduit '•':. 0 36'Setbatic a D . ,t'r54•4 . Solar Arrsy2 :!'v•r �,<�''•:<• 18'Setback 2 Hanwha O.Peak 385W qiiekir CI 2 P400 Optimizers N:). w - - Pittlr.l8 Deg • a D •♦♦ a D 4.4 mill Orientation:1800-. 4 • " �ti m F sTin a El .f�a` D a I D j CONTRACTOR Mira SW i/ True Power Solar b D a D Address: 201/ Clark Ave Solar Anita Pomona,CA 91]8] 8 Hanwha O.Peak 385W1' i b 0 a O j Phone Number: 8 POO Optimizers m (IfQ W68896 Pitch:18 Deg type:G6 Orientation:270 Deib D j t Lk N Licit 970591 O ° Y,4 TRUE PSWER OLAR b °❑ b ❑ Solar Array b ❑jpippr 8 Mamba O.Peak 385W 8 P400 Optimizers Pitch:18 Deo b ❑ Orientation:270 D=• ° A EU s. vo{ k e'e Gupe/lam Sresty \\ 1627 Oakheven Dr. Note:AD exposed equipment and conduit shall be painted to match the roof and wall. ®FO EMI „P Arcadia,CA 91006 Note:Existing roof tiles shall be maintained. SCALE .w.a720,20 _ FROM JUNCTION BOX TO ROOF EAVE EMT TYPE CONDUITWLL RUN OVER I I I 1 wS INDICATED THE ROOF AT312'HEIGHT,THEN UNDER THEFAVE TO PV EQUIPMENT 01 5 Ion w IV MEM