Loading...
HomeMy WebLinkAboutUntitled . r _ Permit Na SOLR-19-1328 v--loeity of Arcadia, CA - Al1 Development Services Department ..f Perml4Type:Solar 240 West Huntington Drive,Post Office Box 60021 ' ,*in ii r + 9 work Classification:Solar-Residential Over 30 KV Arcadia,r� Arcadia,CA 91066-6021 ) ! tt ,J u �..f W i (626)574-5416 . - Permit Status:Issued ARCADIA _ IssueDate:07/16/20191 Expiration: 01/07/2020 Addr NO. Dir Prefix Street Name Street Suffix Unit City,State,Zip Parcel Number 610 Estrella AVE Arcadia,CA 5785015015 Contacts MARCO&GLENDA LOPEZ Owner SOUTH WEST DEVELOPMENT INC" Contractor 610 ESTRELLA AVE 12517 SHERMAN WAY B,NORTH HOLLYWOOD,CA 91607 (323)301-0672 1031232 Description:ROOF MOUNTED SOLAR SYSTEM 38 MODULES,125 Valuation: $ 0.00 Tenant AMP SUB PANEL Total Sq Feet: 0.00 Plan Check tl Plan p Fees Amount Payments Amount Paid Building Plan Check Fee Residential $50.00 Total Fees $324.72 Distribution Panel $16.48 Cash/Receipt tt REC-01839-19 $324.72 Electrical Permit Issuance Fee $47.01 Amount Due: $0.00 Fire Plan Check Fee Residential $50.00 Inverters $77.78 Panels $82.45 __ C/ izets.../. Solid Waste Management Fee 2 $1.00 Cjfl,Q C. G..4-f[ 2r-7 / • Total: $324.72 Eiii co,, y y :JF '6. f 'C- LLS FOR INSPECTIONS Request for inspection by telephone at 626-574-5450. Leave a message requesting the address,timeframe and what inspection item is needed. This permit/plan review expires by time limitation and becomes null and void if the work authorized by the permit is not commenced within 180 days from the date of issuance or if the permit is not obtained within 180 days from the date of plan submittal.This permit expires and becomes null and void if any work authorized by this permit is suspended or abandoned for 180 consecutive days or if no progressive work has been verified by a City of Arcadia building inspector for a period of 180 consecutive days. -4 _ .1111 . a 'V July 16,2019 Issued By: Date July 16,2019 Page 1 of 1 •FAR • .cyroRdv.i e PERMIT/PLAN REVIEW APPLICATION @3j Development Services.. ervices Department,240 West Huntington Drive, Post Office Box 60021 Arcadia, CA 91066-6021, (626) 574-5416,Fax (626) 447-9173 City of Arcadia • LICENSED CONTRACTOR'S DECLARATION WORKERS'COMPENSATION DECLARATION ❑ I hereby affirm under penalty of perjury that I am licensed under provisions of I hereby affirm under penalty of perjury one of the following: Chapter 9(commencing with Section 7000,of Division 3 of the Business and Professions Co e,and my license is in full fo • elle 0 I have and will maintain a certificate of consent to self-insure for workers' License Class Signature of Contractor License No I ` a.-Datl/ -iiL compensation, as provided for by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. OWNER-BUILDER DECLA'v t!r:'` 0 I have and will maintain workers'compensation insurance,as required by Section ❑ I hereby affirm under penalty of perjury the n exempt from the Contractors 3700 of the Labor Code,for the performance of the work for which this permit License Law for the following reason(Section 7031.5,Business and Professions is issued.My workers'compen tion rnsu rand policy numbers are: Code.Any city or county which requires a permit to construct,alter,improve, Carrier -_ demolish,or repair any structure,prior to its issuance,also required the applicant for such permit to file a signed statement that he or she is licensed pursuant to the P. ' Y Number provisions of the Contractors License Law(Chapter 9(commencing with Section section need not be completed if the permit is for one hundred dollars or less) 7000)of Division 3 of the Business and Professions Code)or that he or she is(irr exempt them from and the basis for the alleged exemption. Any violation of +v that in the performance of the work for which this permit is' ued,I shall Section 7031.5 by any applicant for a permit subjects the applicant to a ci ' r/ of employ any person in any manner so as to become subject o workers' penalty of not more than five hundred dollars($500)): �•mpensation Laws of California,and agree that if I should .me bject to the workers'compensation provisions of Section 3700 of the. abo Code,I shall ❑I, as owner of the property, forthwith comply s Th those provisions. or my employees with wages as their sole � .� compensation,will do the work,and the structure is not intended or offered for sale(Section 7044,Business and Professions Code:The Contractors License Date ,. , Signature Law does not apply to an owner of property who builds or improves thereon, or who does such work himself or herself or through his or her own employees,provided that such improvements are not intended or offered for WARNING: Failure to secure Workers'Compen ..••• •vemge is unlawful, sale.If,however,the building or improvement is sold within one(1)year of and shall subject an employer to criminal penalties and civil fines up to one completion,the owner-builder will have the burden of proving that he or she hundred thousand dollars($100,000),in addition to the cost of compensation, did not build or improve for the purpose of sale). damages as provided for in Section 3706 of the Labor Code, interest, and attorney's fees. ❑I, as owner of the property, am exclusively contracting with licensed contractors to construct the project(Section 7044,Business and Professions Code:The Contractors License Law does not apply to an owner of property CONSTRUCTION LENDING AGENCY who builds or improves thereon,and who contracts for such projects with a I hereby affirm under penalty of perjury that there is a construction lending agency contractor(s)licensed pursuant to the Contractors License Law). for the performance of the work for which this permit is issued (Section 3097, Civil Code). 0 I am exempt under Section 7044,Business and Professions Code,for this mason: Lender's Name Date _Signature Lender's Address IMPORTANT: APPLICATION IS HEREBY MADE TO THE BUILDING OFFICIAL FOR A PERMIT SUBJECT TO THE CONDITIONS AND RESTRICTIONS SET FORTH ON THIS APPLICATION AND THE FOLLOWING: 1. The City's approved plans and permit inspection card must remain on the job site for use by City inspection personnel. 2. Final inspection of the work authorized by this permit is required.A Certificate of Occupancy must be obtained prior to use and occupancy of new build>ttgs and structures. . 1 3. Per South Coast Air Quality Management District(AQMD)regulations,renovation and remodeling work that results in the removal,stripping,or altenp of asbestos containing materials requires an asbestos survey and removal prior to disturbing the asbestos. Please contact AQMD at(909)396-2000 for further information. arae As ' . ILS Title I /aa IP -A . .. NAN f — I ertify that I have read this application and state that the above informal : is correct and that I am the owner or duly authorized agent of the owner. I agree to comply with all City ordinances and State Laws relating to building construction. I hereby authorize representatives of the City of Arcadia to enter upon the above- P •'• My for inspection purposes. ignamre V \Date k.7 (1 6 \\ WV \ \ \ _ GENERAL NOTES I.THIS SYSTEM COMPLIES WITH THE 2016 CRC,2016 CBC.2016 CFC,AND THE 2016 10. ANY CONDUCTORS BEM CEC. PROTECTED IN CONDUIT. U e 2.THE SYSTEM WILL NOT BE TURNED-ON UNTIL THE SERVING UTILITY COMPANY HAS 11. THE EQUIPMENT CROUNDIt BEEN NOTIFIED. FROM PHYSICAL DAMAGE. IM RAILS AND SECURED IN PLACE. 3.THE INSTALLED SOLAR SYSTEM HAS A DISTRIBUTED WEIGHT LESS THAN 4 PSF. 12.THE MODULES WILL BE ATL 4.THE CONCENTRATED LOAD FOR EACH VERTICAL SUPPORT IS LESS THAN 40 LBS. IN ACCORDANCE WITH THE MAI' 5.ALL PV EQUIPMENT IS LISTED BY A RECOGNIZED TESTING LAB.INVERTERS ARE UL 13.ALL EXTERIOR CONDUIT, Fl 1741 COMPLIANT. FOR USE IN WET LOCATIONS. 6.THE BACKFED'BREAKER WILL BE LOCATED AT THE OPPOSITE END OF THE BUS 14. CLEARANCES AROUND FROM THE MAN BREAKER. ACCORDANCE WITH CEO 110,2E 7.CONDUCTORS ARE 90 C RATED COPPER WIRE. 15.SOLAR MODULES WILL NOT ROOF VENTS. 8.ANY CONDUCTORS EXPOSED TO SUNLIGHT ARE LISTED AS SUNLIGHT RESISTANT. 16.IF THE EXISTING MAIN SERV 9.IF DC CONDUCTORS ARE RUN INSIDE THE BUILDING,THEY WILL BE CONTAINED IN A ELECTRODE SYSTEM,A GROU METAL RACEWAY. CEC 250.50..THE ELECTRICAL PIPING PER SECTION 250.104 01 ESTRELLA AVE -- r — _ — PL- — — — — w CO z a a QNo I t dd-- x z cc C - O j Q -1 (E)GARAGE o p Q l���_ •rLvfJ In OF Foil • ellli��T=iw�=r} UMW a iGitiY C\Y VV rz p_ •>�6 -Y - w U 0 Y�1I�Y� :flll��� -_ Y�I • 4-70• I J Q _Z Y •YYEJYY. ��YYYYYMMMss fC w+i±t n/!rte b -- I -'1- Q x • Y�Y I YE = YYYv CCCY Y ,,I- O J V Q IYY 4.„„.., M YM - �Y Y Jule _121.-. a 1p -,_ v' i. Y II Ys, .1 nal I f__F.t___C4}!_ �*t.t ._ El' y 1 , II 1c—f Iy I I I TI ��- Y�----�-�Y raIIY�-�. - YYYYY - x Y Y� 7 — - -fi.T � II- rt �_ �YYes— Ytniri SE �Y �111.1 6rf� Y .1. Rh YYYYI�allilliMPIIIMINI•w� =� c7 L 01 t-? S; 111111flal I I ell I.._L YYt� Y YrYYl O v MIN=ran .I c d S�W �Y - �YY�yrI �YY1����L�YY��YYY Y. pawN�I a.wlm 12 a�s 1::::(1) I _!L- YYYYY YYYYY Eg I,'7_111-1%krip C.z� a YYYY 4. MINI apt ■ i_. _.._. IY�I __= mailtii maw YY PVMFDU -0- 1 PLOT MAP RPV OOF MOUNTED LES Scale:3/32"=1'-0"