HomeMy WebLinkAboutUntitled i PermrcJVo I. SOLR-19-0828
tCity of Arcadia, CA
Development Services Department ` "v���rv`` l n
PJ a } f —; `5 PermitType:bolar
240 West Huntington Drive,Post Office Box 60021 )- ic��tr 1J 11 I]U , �,
Arcadia,CA 91066-6021 J t Y`EJ.Work Classification:Solar—Residential
(626)574-5416 - - Permit Status:Issued
ARCADIA ' IssueDate,05/02/20191 Expiration: 10/29/2019
Addr NO. Dir Prefix Street Name Street Suffix Unit City,State,Zip Parcel Number
[229 E Floral AVE Arcadia,CA 5772018021
Contacts
JANET BAKER Owner SUNPOWER CORPORATION SYSTEMS* Contractor
229 FLORAL AVE,ARCADIA,CA 91006 1414 Harbour WAY#1901,Richmond,CA
(408)218-6811 890895
Description:ROOF MOUNT PV SYSTEM, 16 MODULES/MIRO Valuation: $ 0.00 Tenant
INVERTERS, 100 AMP LOAD CENTER
Total Sq Feet: 0.00 Plan Check N Plan it
Fees Amount payments Amount Paid
Building Plan Check Fee Residential $50.00 Total Fees $324.72 .
Distribution Panel $16.48 Cash/Receipt#REC-01114-19 $324.72
Electrical Permit Issuance Fee $47.01
Fire Plan Check Fee Residential $50.00 Amount Due: $0.00
Inverters $77.78 �q
Panels $82.45 COMPLETED
Solid Waste Management Fee 2 $1.00 IN
Total: $324.72
1�r.7AL 6. 12 '(9 ••••----••••---- CALLS FOR INSPECTIONS
Request for inspection by telephone at 626-574-5450. Leave a message
requesting the address,timeframe and what inspection item is needed.
This permit/plan review expires by time limitation and becomes null and
void if the work authorized by the permit is not commenced within 180 days
from the date of issuance or if the permit is not obtained within 180 days
from the date of plan submittal.This permit expires and becomes null and
void if any work authorized by this permit is suspended or abandoned for 180
consecutive days or if no progressive work has been verified by a City of
Arcadia building inspector for a period of 180 consecutive days.
May 02, 2019
Issued By: Date
May 02,2019 Page 1 of 1
t.O.
,• ` PERMIT/PLAN REVIEW APPLICATION
-+
'E13*' Development Services Department,240 West Huntington Drive,Post Office Box 60021
°-.,',,.c Arcadia, CA 91066-6021, (626) 574-5416,Fax (626)447-9173
City of
Arcadia
LICENSED CONTRACTOR'S DECLARATION WORKERS'COMPENSATION DECLARATION
❑ I hereby affirm under penalty of perjury that I am licensed under provisions of I hereby affirm under penalty of perjury one of the following:
Chapter 9(commencing with Section 7000,of Division 3 of the Business and
Professions Co,dejj��and�,,,m, �y..license is in full force and effect ^^'' / 0 I have and will maintain a certificate of consent to self-insure for workers'
License Class �� License Noir 40 RS 6—Exp. Date /28/Q) compensation, as provided for by Section 3700 of the Labor Code, for the
•"rf.nuance of the work for which this permit is issued.
Signature of Contractor i✓ _i
O -BUILDER DECLARATION tt I have and will maintain workers'compensation insurance,as required by Section
under penalty of perjury that I am exempt from the Contractors 3700 of the Labor Code,for the performance of the work for which this permit
I hereby affirm
License Law for the following reason(Section 7031.5,Business and Professions is issued.My won kers'co ensation insurance carrier and policy numbers are:
Code.Any city or county which requires a permit to construct,alter,improve, Carrier Hely y/!Cid
demolish,or repair any structure,prior to its issuance,also required the applicant
Policy Number 14/144400/5~
for such permit to file a signed statement that he or she is licensed pursuant to the (This section need not be completed if the permit is for one hundred dollars or less)
provisions of the Contractors License Law(Chapter 9(commencing with Section
7000)of Division 3 of the Business and Professions Code)or that he or she is M I certify that in the performance of the work for which this permit is issued,I shall
exempt there from and the basis for the alleged exemption. Any violation of
Section 7031.5 by any applicant for a permit subjects the applicant to a civil not employ any person in any manner so as to become subject to the workers'
penalty of not more than five hundred dollars($500)): compensation Laws of California,and agree that if I should become subject to the
workers'compensation provisions of Section 3700 of the Labor Code,I shall
I, as owner of the property, forthwith comply with those provisions.
or my employees with wages as their sole
compensation,will do the work,and the structure is not intended or offered for Date c/a/(.Q
Signature
sale(Section 7044,Business and Professions Code:The Contractors License
Law does not apply to an owner of property who builds or improves thereon,
or who does such work himself or herself or through his or her own
employees,provided that such improvements are not intended or offered for WARNING: Failure to secure Workers'Compensation coverage is unlawful,
sale.If,however,the building or improvement is sold within one(1)year of and shall subject an employer to criminal penalties and civil fines up to one
completion,the owner-builder will have the burden of proving that he or she hundred thousand dollars($100,000),in addition to the cost of compensation,
did not build or improve for the purpose of sale). damages as provided for in Section 3706 of the Labor Code, interest, and
attomey's fees. ..
0 I, as owner of the property, am exclusively contracting with licensed
contractors to construct the project(Section 7044,Business and Professions
Code:The Contractors License Law does not apply to an owner of property CONSTRUCTION LENDING AGENCY
who builds or improves thereon,and who contracts for such projects with a I hereby affirm under penalty of perjury that there is a construction lending agency
contractor(s)licensed pursuant to the Contractors License Law). for the performance of the work for which this permit is issued (Section 3097,
Civil Code).
0 I am exempt under Section 7044,Business and Professions Code,for this reason:
Lender's Name
Date Signature Lender's Address
IMPORTANT: APPLICATION IS HEREBY MADE TO THE BUILDING OFFICIAL FOR A PERMIT SUBJECT TO THE CONDITIONS AND
RESTRICTIONS SET FORTH ON THIS APPLICATION AND THE FOLLOWING:
1. The City's approved plans and permit inspection card must remain on the job site for use by City inspection personnel.
2. Final inspection of the work authorized by this permit is required.A Certificate of Occupancy must be obtained prior to use and occupancy of new buildings
and structures.
3. Per South Coast Air Quality Management District(AQMD)regulations,renovation and remodeling work that results in the removal,stripping,or altering
of asbestos containing materials requires an asbestos survey and removal prior to disturbing the asbestos.Please contact AQMD at(909) 396-2000 for
further information. / �(
am /' f a 5'P GI L/. ..ft-/G!/ (/� Title
PRINT NAME
certify that I have read this application and state that the above information is correct and that I am the owner or duly authorized agent of the owner.
agree to comply with all City ordinances and State Laws relating to building construction. I hereby authorize representatives of the City of
rcadia to enter upon the above-mentioned property for inspection purposes.
Signature _ Date ,(07//,
' 5
PtV\fER
TM
4/25/2019
Attn.: To Whom It May Concern
re: Job JANET BAKER: 229 EAST FLORAL AVENUE, ARCADIA, CALIFORNIA 91006
The following calculations are for the structural engineering design of the photovoltaic
panels.
After review, I certify that the roof structure has sufficient structural capacity for the
applied PV loads.
• All PV mounting equipment shall be designed and installed per manufacturer's approved
installation specifications.
SS
If you have any questions, don't hesitate to contact. l
pJIHA Nglc,
C 84486 r+
J �
Sincerely, * EXP. 09/30/2019 *
Ali Hajihashemi, RE tr>.
97 CIVIL oQ�
FOF cp
Design Criteria: ®®,
Code: 2016 California Building Code
ASCE 7-10
Live Load: 20 psf
Ult Wind Speed: 110 mph
Exposure Cat: B
Ground Snow: 0 psf
2125 E Katella Ave#220,Anaheim,CA 92806 1714.787.3850
Date :4/25/2019 it
Job Code:JANET BAKER
SU N POW E RT'' 2of6
Structrure Geometry:
Mean Roof Height, hn = 23 ft
Eave Height, he = 18 ft
Buidirig Length, L = 53 ft
Building Width, B = 39 ft
Module Area = 17.5 ftz
Roof Properties:
Roof 1
Roof Pitch (deg)= 28
Roofing Type= Comp Shingle
Sheathing Type= 5/8 OSB Sheathing
•
Wood Species= Doug Fir-Larch#2
Wood Fb (psf)= 129600
Wood Fv(psf)= 25920
Wood E(psf)= 230400000
Wood Lag Withdrawal (Ib/in)= 266
Framing Type= 2x8 Rafter
Framing OC Spacing(in.)= 24
Section Thickness, b (in.)= 1.50
Section Depth,d (in.)=
7.25
Section Modulus,Sx(in.^3)= 13.14
Beam Span (ft)= 13
Pen Trib Width (ft)=
Rail Span (ft) = 2.55
Co(Wind)= 6.00
CD(Snow)= 1.6
1.15
Cis= 1.15
C^^= 1.0
C< 1.0
CL= 1.0
Cf= 1.2
Cfu= 1.0
Ci= 1.0
C,= 1.15
Mallowable_Wind (lb-ft)= 2503
Mallowable snow(lb-ft)= 1799
2125 E Katella Ave#220,Anaheim,CA 92806 714.787.3850
Date :4/25/2019
Job Code:JANET BAKER
SUNPC WERTM 3of6
Dead Load:
CompStiingi 3.0
5/8 OSB Sheathing 2.0
2x8 Rafter @ 24" OC 1.2
Misc(Insulation etc) 1.0
Total Roof 1 DL 7.2 psf
PV DL 2.8 psf
Roof 1
Roof_Dist_DL= 13
M Roof Dist DL= 270
Def Roof Dist DL= 0.0090
PV_uni Dist_DL= 5
M_PV_uni Dist_DL= 105
Def_PV_uni_Dist_DL= 0.0035
Total_uni_DL= 18
M_Total_uni DL= 375
Def Total uni DL= 0.0125
Rail_Down_DL= 6
Rail_M_DL= 51
Pens_Down_DL= 51
Pens Side DL= 27
Wind Load:
Ultimate Wind Speed = 110 mph
Directionality Factor, kd= 0.85
Topographic Factor, kzt= 1
Velocity Pressure Exposure Factor, kz= 0.70
Velocity Pressure, qz= 18.45
Roof 1
2125 E Katella Ave#220,Anaheim, CA 92806 1714.787.3850
Date :4/25/2019
Job Code:JANET BAKER
4 of 6
External Pressure Up,GCp_1= -0.95
External Pressure Up, GCp_2= -1.50
External Pressure Up, GCp_3 = -1.15
External Pressure Down, GCp= 0.85
Design Pressure Up, p_i= -17.52
Design Pressure Up, p_2= -27.67
Design Pressure Up, p_3= -21.21
Design Pressure Down, p= 16.00
uni_Dist_W_up -35
M_uni_Dist_W_up= -740
Def uni_Dist_W_up= -0.0246
uni_Dist_W_down= 32
M_uni_Dist_W_down= 676
Def uni Dist Wdown= 0.0225
Module_Up_W1= -18
Module_Up_W2= -28
Module Down W= 16
Rail_Up_W1= -45
' Rail_Up_W2=. -71
Rail_Down_W= 41
Rail_M_Up_W1= -358
Rail_M_Up_W2= -565
Rail MDown W= 327
Pens_Up_W1= -358
Pens_Up_W2= -565
Pens Down W= 327
Module Check(Service Level):
Roof 1 Down = 16 psf c 125 psf OK
Roof 1 Up zl = 18 psf c 62 psf OK
-
Rail Check(LRFD):
2125 E Katella Ave#220,Anaheim,CA 92806 1714.787.3850
OE Date :4/25/2019
•
Job Code:JANET BAKER
S- U N POWER' 5 of 6
Roof1 1.4D : 71 lb-ft < 548 lb-ft OK
Roofl 1.2D+1.6S+0.5W: 224 lb-ft < 548 lb-ft OK
Roof1 1.2D+0.55+ 1.0W: 388 lb-ft < 548 lb-ft OK
Roof1 0.9D+ 1.0W(Up z1) : 312 lb-ft < 580 lb-ft OK
Attachment Check(ASD):
Roofl 1.0D+0.6W : 247 lbs < 1254 lbs OK
Roofl 1.OD+0.75*[1.OS+0.6W] : 198 lbs < 1254 lbs OK
Roof1 1.0D+1.05 : 51 lbs < 1254 lbs OK
Roofl 0.6D+0.6W(Up z1) : 184 lbs < 1254 lbs OK
Attachment Lateral Check(ASD):
Roof1 1.0D+1.05 : 27 lbs < 1536 lbs OK
Lag Screw Uplift Check(ASD):
5/16" Lag Screw Withdraw)Value= 266 lbs
Lag Screw Penetration= 2.5 in.
Roof1 0.6D+0.6W (Up zl) : 184 lbs < 665 lbs OK
Framing Check(ASD):
Roofl uni 1.0D+0.6W : 781 lb-ft < 2503 lb-ft OK
Roof1 uni 1.0D+0.75*[1.0S+0.6W] : 679 lb-ft < 2503 lb-ft OK
Roofl uni 1.0D+ 1.OS : 375 lb-ft < 1799 lb-ft OK
Roofl uni,0.6D+0.6W(Up zl) : 219 lb-ft < 2503 lb-ft OK
Seismic Check:
Stucco 10.0 psf
2x4 Studs @ 16" 2.0 psf
Gypsum 3.0 psf
Misc. (Insulation,etc.) 2.0 psf
2125 E Katella Ave#220,Anaheim, CA 92806 1714.787.3850
Date :4/25/2019 iC
Job Code:JANET BAKER
S U N P W E RTM 6 of 6
Total Wall DL= 17 psf
Total Wall Area= 3312 ft^2
Total Wall W= 56304 lbs Existing Weight
Total Roof DL= 7 psf
Total Roof Area= 2067 ftA2
Total Roof W= 14978 lbs Existing Weight
PV Panel W= 46 lbs
Number of Panels= 16
Total PV W= 728 lbs Additional Weight
increase=(Wexisting+Wadditional)/Wexisting = 1% OK
The increase in weight as a result of the solar system is less than 10%of the existing structure and therefore no
further seismic analysis is required.
Limits of Scope of Work and Liability
The calculations produced for this dwelling's assessment are only for the proposed solar panel installation
referenced in the stamped plan set and were made according to generally recognized structural anlaysis standards
and procedures.
2125 E Katella Ave#220,Anaheim,CA 92806 1714.787.3850
LEGEND K 1,
D JUNCTION BOX 4F§
CONDUIT n- 41
Z 1.11
O EXISTING SERVICE POINT
(E)DETACHED STRUCTURE AND UTILITY MEI ERING in M. 49
—��//-— PROPERTY LINE
W.74' 3'WIDE ACCESS PATH
® NEW LOAD CENTER
ROOF ACCESS
ELECTRIC
G
TO 7POIN
UTILITY
GRID
CIElt
l,r u C
...a. //://////,77////_
y,, ,, 5 N h y MGPIAODMLO ACTUAL PHOTO
/iy x i5 0 Ib' -
us
a/ ian aZ I/-(E) n
Y61 rk
a w o u
�f ROOF ONE;16 MODULES K O w t
JNOTE: .4 E
'JP,
A 1.HELD ADJUSTMENTS OF FEWER Y a y w O
/ THAN 6'MAY BE ALLOWED BASED ON SITE a O O
/, CONDITIONS AND MEASUREMENTS. s O
/i{ 2.QUAD OR TWIN BREAKER MAY BE 0. G S D^ ,_
� REQUIRED. 2
/ I (E)FENCE/GATE 5. b w S o a
E W
1 Y N < o
te
+l 39'
rt
I°---e—° I RevN REVISIONS 44n ma
m
CONTRACT MODULE QUANITPY SPR-%22-360E-AC(200)(16)
Zo
INVERTER'TYPESPR-%22-360-E-AC(200)(16)
ROC*TTPE COMPOSITION
— —
St ROOF ATTACHMENT 20 xnsuun
UANTITY
EAST FLORAL AVENUE ‘10. ST � 04 23 2019
W ILMA.
ROME PE
2-S STORY OR1ENTAnox 180° 5-.. WOE,
ROOF PROM 6.$:12 otre
MDHrtaRINDN TBD PVA-1
•
Lp4'jji
d i P
egg ,�:r�.cb_ -
07,
AFFIDAVIT SELF-CERTIFICATION
FOR COMPLIANCE OF SMOKE ALARMS
AND CARBON MONOXIDE ALARMS
Property Address: 2 ? 6.' -/ / ,42ooi4 ad l 9/O1,/
Permit Number: 532,P_
Brief Job Description: /2445 LeV 2
Number of smoke alarms installed: 5 ^ -
Number of carbon monoxide alarms installed:
When alterations, repairs or additions requiring a permit occur, or sleeping rooms are created,
Smoke alarms shall be installed in each sleeping room, and outside each separate
sleeping area in the immediate vicinity of the bedrooms, and on each additional story of the
dwelling, including basements and habitable attics as required by Section R314 of the 2016
California Residential Code (CRC) and California Health and Safety Code Section 13113.7.
For dwellings or sleeping units containing fuel burning appliances or having attached
garages, carbon monoxide alarms shall be installed outside each separate sleeping
area in the immediate vicinity of-the bedrooms, and on each additional story of the
dwelling, including basements as required by Section R315 of the of the 2016 California
Residential Code (CRC).
Multi-purpose alarms (combination carbon monoxide and smoke alarms) may be used.
All alarms shall comply with requirements for listing and approval by the Office of the State Fire
Marshal. http://osfm.fire.ca.qov/licensinglistings/licenselistinq bml searchcotest.php
As owner of the above referenced property, I hereby certify that the smoke alarms and carbon
monoxide alarms have been installed in accordance with the manufacturer's instructions and in
compliance with the code sections referenced above.
I declare under penalty of perjury that the foregoing is true and correct, and that this
declaration was executed on (Date) 1.102-77 at Arcadia, California.
Owner's Name (printed/ty..ed): et 73ars
Signature of Owner: "' :•/ �/
This affidavit must be -turned to the City of Arcadia inspector prior to final inspection
SMOKE ALARM AND CARBON MONOXIDE ALARM LOCATIONS .
Room _ B
•athrou
GuestI • Storage
I I Family Room lir
Garage
. 1.-------------- Piill
FIRST FLOOR PLAN
e= SMOKE ALARM , = CARBON MONOXIDE ALARM
I t_ mitt
Pi Master Bedroom
Dining Room Kitchen
30
Ratti
Wall FT I G'triloset
Cd
_- Closet Closet
Family Room
®- — Bedroom Bedroom
SECOND FLOOR PLAN
S SMOKE ALARM , = CARBON MONOXIDE ALARM