Loading...
HomeMy WebLinkAboutUntitled s City of Arcadia, CA liPermitNO SOLR19 1592 Development Services Department itThr, '^, Permit Type:Solar 240 West Huntington Drive,Post Office Box 60021 i rf k ' ;') n 1 ] i i Arcadia,CA 91066-6021 e Q t- Work Qassi cation Solar-Residential Over 10 KV_ (626)574-5416 _ - - ;Permit Status issued ARCADIA Issue•Date:08/13/2019 Expiration: 02/09/2020 Addr NO. Dir Prefix Street Name Street Suffix Unit City,State,Zip Parcel Number 468 Rosemarie DR Arcadia,CA 5787008022 W Contacts . . . _ . x _ .x. _. ,�_ ,.. �.... _.. ,..... DARSHAN KAMBOJ Owner TESLA ENERGY* Contractor 468 ROSEMARIE DR 3055 Clearview Way,San Mateo,CA 94402 (323)240-3174 888104 Description:ROOF MOUNT PV SYSTEM, 39 MODULES/2 Valuation: $ 0.00 Tenant INVERTERS Total Sq Feet: 0.00 _ Plan Check N Plan k Fees Amount payments Amount Paid Building Plan Check Fee Residential $50.00 Total Fees $386.02 Electrical Permit Issuance Fee $47.01 Cash/Receipt ft REC-02120-19 $386.02 Fire Plan Check Fee Residential $50.00 Amount Due: $0.00 Inverters $155.56 Panels $82.45 Solid Waste Management Fee 2 $1.00 Total: $386.02 -� COMPLETED frirt,L.. 9u .(? CALLS FOR INSPECTIONS Request for inspection by telephone at 626-574-5450. Leave a message requesting the address,timeframe and what inspection item is needed. This permit/plan review expires by time limitation and becomes null and void if the work authorized by the permit is not commenced within 180 days from the date of issuance or if the permit is not obtained within 180 days from the date of plan submittal.This permit expires and becomes null and void if any work authorized by this permit is suspended or abandoned for 180 consecutive days or if no progressive work has been verified by a City of Arcadia building inspector for a period of 180 consecutive days. August 13,2019 Issued By: Date August 13,2019 Page 1 of 1 • 'R ..IFORO/„./ I .... s,1 1 PERMIT/PLAN REVIEW APPLICATION it IS 11 E4;<*' Development Services Department, 240 West Huntington Drive,Post Office Box 60021 ti Arcadia, CA 91066-6021, (626) 574-5416, Fax (626) 447-9173 City of Arcadia LICENSED CONTRACTOR'S DECLARATION WORKERS'COMPENSATION DECLARATION ❑ I hereby affirm under penalty of perjury that I am licensed under provisions of I hereby affirm under penalty of perjury one of the following: Chapter 9(commencing with Section 7000,of Division 3 of the Business and Professions Code,and my license is in full force and effect. ❑ I have and will maintain a certificate of consent to self-insure for workers' License Class 6-ft e No. I Dc(_ Exp. Date compensation, as provided for by Section 3700 of the Labor Code, for the Signature of Contractor performance of the work for which this permit is issued. OWNER-BUILDER DECLARATION Il-rave and will maintain workers'compensation insurance,as required by Section 0 I hereby affirm under penalty of perjury that I am exempt from the Contractors 3700 of the Labor Code,for the performance of he work for wh ch his permit License Law for the following mason(Section 7031.5,Business and Professions is issued.My workers'compensation insurance carrier and policy numbers are: Code.Any city or county which requires a permit to construct,alter,improve, Carrier CCe-VN demolish,or repair any structure,prior to its issuance,also required the applicant Policy Number \f---iCr+.)\ Ztl \�{ for such permit to file a signed statement that he or she is licensed pursuant to the provisions of the Contractors License Law(Chapter 9(commencing with Section (This section need not be completed if the permit is for one hundred dollars or less) 7000)of Division 3 of the Business and Professions Code)or that he or she is exempt there from and the basis for the alleged exemption. Any violation of ❑ I certify that in the performance of the work for which this permit is issued,I shall Section 7031.5 by any applicant for a permit subjects the applicant to a civil not employ any person in any manner so as to become subject to the workers' penalty of not more than five hundred dollars($500)): compensation Laws of ralifomia,and agree that if I should become subject to the workers'compensation provisions of Section 3700 of the Labor Code,I shall ❑I, as owner of the property, or my employees with wages as their sole forthwith �comply with those provisions. compensation,will do the work,and the structure is not intended or offered for Date U'\`)—\t Signature c sale(Section 7044,Business and Professions Code:The Contractors License Law does not apply to an owner of property who builds or improves thereon, or who does such work himself or herself or through his or her own employees,provided that such improvements are not intended or offered for WARNING: Failure to secure Workers'.Compensation coverage is unlawful, sale.If,however,the building or improvement is sold within one(1)year of and shall subject employer to criminal penalties and civil fines up to one completion,the owner-builder will have the burden of proving that he or she hundred thousand dollars($100,000),in addition to the cost of compensation, did not build or improve for the purpose of sale). damages as provided for in Section 3706 of theLabor Code, interest, and attorney's fees. ❑I, as owner of the property, am exclusively contracting with licensed contractors to construct the project(Section 7044,Business and Professions Code:The Contractors License Law does not apply to an owner of property CONSTRUCTION LENDING AGENCY who builds or improves thereon,and who contracts for such projects with a I hereby affirm under penalty of perjury that there is a construction lending agency contractor(s)licensed pursuant to the Contractors License Law). for the performance of the work for which this permit is issued (Section 3097, Civil Code). ❑ I am exempt under Section 7044,Business and Professions Code,for this reason: Lender's Name Date Signature Lender's Address IMPORTANT: APPLICATION IS HEREBY MADE TO THE BUILDING OFFICIAL FOR A PERMIT SUBJECT TO THE CONDITIONS AND RESTRICTIONS SET FORTH ON THIS APPLICATION AND THE FOLLOWING: 1. The City's approved plans and permit inspection card must remain on the job site for use by City inspection personnel. 2. Final inspection of the work authorized by this permit is required.A Certificate of Occupancy must be obtained prior to use and occupancy of new buildings and structures. 3. Per South Coast Air Quality Management District(AQMD)regulations,renovation and remodeling work that results in the removal,stripping,or altering of asbestos containing materials requires an asbestos survey and removal prior to disturbing the asbestos.Please contact AQMD at(909)396-2000 for further information. Name x s.ror\ \r--C t\\:o-'r" S Title k s¢fre'r PRINT NAME I certify that I have read this application and state that the above information is correct and that I am the owner or duly authorized agent of the owner. I agree to comply with all City ordinances and State Laws relating to building construction. I hereby authorize representatives of the City of Arcadia to enter upon the above-mentioned property for inspection purposes. Signature Date 1 Date 8 �C\ Version#78.0-1 , 0 SS p NAS QQit I r 44.‘ -orletv .0364 August s,2019 CO� ¢ N 2. S 5185 g+t RE: CERTIFICATION LETTER * .Exp 12/31/20 * Project/Job#JB-9103007-00 Sj• ` et' Project Address: Kamboj Residence 'oT � � 468 Rosemarie Dr F OF: ALF Arcadia,CA 91007 "STRONLY" Abelardo �a`"`°"•""" " °rte AHJ Arcadia De Vera SC Office Atwater Village Design Criteria: -Applicable Codes=Structure:2016 CEBC;PV:2016 CBC/CRC,ASCE 7-10,and 2015 NDS -Risk Category=II -Wind Speed=110 mph,Exposure Category C,Partially/Fully Enclosed Method -Ground/Roof Snow Load=0 psf -MP1:Roof DL=14 psf,Roof LL=20 psf -MP2:Roof DL=14 psf,Roof LL=20 psf -MP3:Roof DL=14 psf,Roof LL=20 psf -MP4:Roof DL=14 psf,Roof LL=20 psf Per Section 1613.1,W-(PV)/W-(exist roof)=4.5%,Increase Seismic Shear Load<10%,->[OK] To Whom It May Concern, A structural evaluation of loading was conducted for the above address based on the design criteria listed above. Based on this evaluation,I certify that the alteration to the existing structure by installation of the PV system meets the prescriptive compliance requirements of the applicable existing building and/or new building provisions adopted/referenced above. Additionally,I certify that the PV module assembly including all standoffs supporting it have been reviewed to be in accordance with the manufacturer's specifications and to meet and/or exceed all requirements set forth by the referenced codes for loading. The PV assembly hardware specifications are contained in the plans/docs submitted for approval. Installer shall verify existing roof framing is in suitable condition and does not exhibit any signs of structural damage which may diminish the capacity of its members or connections prior to commencement of PV installation.This inspection is required because the home was not entered and the attic structure was not reviewed prior to the structural evaluation performed for this report. 1 Sincerely - - '- 1 • Abe De Vera,PE;SE CITY OFARC4DIA • Structural Engineer. '' - Development Services i)epartnll'nt Phone:888.765.2489,x57526 :. ' A('�'�2(�S � Email:adevera@tesla.com ` This set of plans and s • pceilications must be kept on the job at all timesand no changes or alterat ons shall he made cArept h� the Building Division. The Stamping nl'tIiicplan and specification shall not be held to permit or to Ire an approval of the violation • ot'any •provisions of any city ordinance or state law Tesla,Inc. T = H L. n 3055 CleaMew Way San Mateo,CA 94402 p 550 638 1028 f 650 638 1029 Version#78.0-1 NAS HARDWARE DESIGN AND STRUCTURAL EVALUATION RESULTS SUMMARY TABLES Landscape Hardware-Landscape Modules'Standoff Specifications Hardware - X-X Spacing' X-X Cantilever Y-Y Spacing Y-Y Cantilever Configuration Uplift DCR MPI 72" 24" 52" 24" Not-Staggered 56.3% MP2 72" 24" 52" 24" Not-Staggered 56.3% MP3 72" 24" 52" _ 24" Not-Staggered 56.3% MP4 72" 24" 52" 24" Not-Staggered 56.3% Portrait Hardware-:Portrait Modules'Standoff Specifications , Hardware -X-X Spacing X-XCantilever Y-Y Spacing Y-Y Cantilever Configuration Uplift DCR MPI 48" 20" 52" 24" Not-Staggered 37.5% MP2 48" 20" 52" 24" Not-Staggered 37.5% MP3 48" 20" 52" 24" Not-Staggered 37.5% MP4 48" 20" 52" 24" Not-Staggered 37.5% Mounting Plane - Roof Pitch ' Qualification Results _ (Degrees) .. Member Evaluation-Results.._ MPI 18° Member Impact Check OK MP2 18° Member Impact Check OK MP3 18° Member Impact Check OK MP4 18° Member Impact Check OK i • - I , - •/ • P 1 Tesla,Inc. .T 5 L 3055 Cle anew Way.San Ma•eo.On 91402 �1 - . n p 650 638 1028 16505381029 PITCH:18 ARRAY PITCH:18 ALL ELECTRICAL EQUIPMENT TO BE46nRosemarie N 46E1 Rosemarie o. MP1 AZIMUTH:89 ARRAY AZIMUTH:89 MOUNTED ON WALL MATERIAE Flat Cement Tile STORY:2 Stades PITCH:18 ARRAY PITCH:18 MP2 AZIMUTH:179 ARRAY AZIMUTH:179 MATERIAL'Flat Cement Tile STORY:2 Stades PITCH:18 ARRAY PITCH:18 MP3 AZIMUTH:269 ARRAY AZIMUTH:269 MATERIAL Flat Cement Tile STORY:2 Stades PITCH:18 ARRAY PITCH:18 MP4 AZIMUTH:179 ARRAY AZIMUTH:179 MATERIAL;Flat Cement Tile STORY:2 Stades — /ems= -•• 619-14 _ 4.•_-'0•/0,e a *prentonieuse LEGEND ss.mN•.55185 'Si * Exp12/31/20 *iEl (E)UTIOTY METER &WARNING LABELINVERTER W/INTEGRATED DC DISCO OF_\3 &WARNING LABELS STR ' •NLY" DC DISCONNECT &WARNING LABELS —�� F Abelardo .,,..q AC DISCONNECT&WARNING LABELSDe Vera- vOa / "° n DC JUNCTION/COMBINER BOX &LABELS •›; • DISTRIBUTION PANEL&LABELS n \ \_ // • •rl n LOAD CENTER & WARNING LABELS miz e �/7 ler �� O DEDICATED PV SYSTEM METER ler ° /. c, / tome. ' ° °,� O RAPID SHUTDOWN Imo' Min • ❑ O 0 /Ay !S ii m1� O STANDOFF LOCATIONS / / / d • CONDUIT RUN ON EXTERIOR �° CONDUIT RUN ON INTERIOR =i"© \_� — GATE/FENCE 0 HEAT PRODUCING VENTS ARE RED ❑❑iI ‘ s. � 1 1,❑❑BI = `VA. Le INTERIOR EQUIPMENT IS DASHED I,1 SITE PLAN N Scale:1/16"=V tE Ol' 6' 32' cSwownM-ramwwaw wsmN ,m waw JB-9103007 OO 0.eI onvwmm DEM aunavm Mew Na BE usm FU 1W Darshan Kamboj12.285 KW PV ARRAY Nathan Graham w�"i1 CC sno.X�i Awa NOR MOND VEDA 468 Rosemarie Dr T 5 L n PORT TO Oran$OUNCE ra memos ZEP Mighty Hook wuuunw,a:aPT N ma¢cnw inn mournArcadia, CA 91007 TIE SALE Mm USE or ma RESTEC1WE (39)Honwha 0-Cells q Q.Peak DUO BLK-GS/5C315 PTESL&ewapIfmAMON INC. "DRUM "'a SITE 3 a"" 9 6263211233 P � Multiple Inverters SITE PLAN 8/7/2019 aN frd 4�cuit,'al" AFFIDAVIT SELF-CERTIFICATION FOR COMPLIANCE OF SMOKE ALARMS AND CARBON MONOXIDE ALARMS Property Address: H G 0.6 f2VUlo.7 1^e Or Permit Number: SO 12 — k G( -p1S� a Brief Job Description: _S�, I. - Y V Number of smoke alarms installed: C Number of carbon monoxide alarms installed: When alterations, repairs or additions requiring a permit occur, or sleeping rooms are created, Smoke alarms shall be installed in each sleeping room, and outside each separate sleeping area in the immediate vicinity of the bedrooms, and on each additional story of the dwelling, including basements and habitable attics as required by Section R314 of the 2016 California Residential Code (CRC) and California Health and Safety Code Section 13113.7. For dwellings or sleeping units containing fuel burning appliances or having attached garages, carbon monoxide alarms shall be installed outside each separate sleeping area in the immediate vicinity of the bedrooms, and on each additional story of the dwelling, including basements as required by Section R315 of the of the 2016 California Residential Code (CRC). Multi-purpose alarms (combination carbon monoxide and smoke alarms) may be used. All alarms shall comply with requirements for listing and approval by the Office of the State Are Marshal. htto://osfm.fire.ca.oov/licensinglistings/licenselistinq bml searchcotest.ohn As owner of the above referenced property, I hereby certify that the smoke alarms and carbon monoxide alarms have been installed in accordance with the manufacturer's instructions and in compliance with the code sections referenced above. I declare under penalty of perjury that the fforegoing is true and correct, and that this declaration was executed on (Date) (t 1 (P / 19II at Arcadia, California. ` Owner's Name (printed/typed): . r 14 o.v\ Lbo i Signature of caner: str.rim This affidavit must be returned to the City of Arcadia inspector prior to final inspection SMOKE ALARM AND CARBON MONOXIDE ALARM LOCATIONS Guest Room Batbroo Storage 0 7 Family Room low TIT_ FIRST FLOOR PLAN t=SMOKE ALARM ., ® CARBON MONOXIDE ALARM Mstr ' L L. Bath AMaster Bedroom Dining Room Kitchen -Ball; hail a u Close— Closet Closet Family Room Bedroom Bedroom SECOND FLOOR PLAN 0'=SMOKE ALARM I m CARBON MONOXIDE ALARM