Loading...
HomeMy WebLinkAboutUntitled p City of Arcadia, CA Permit No SOLR 19 2179 k' .. Development Services Department 4 D f v -v ~ Y•� ." - Permlt Type Solar 240 West Huntington Drive,Post Office Box 60021 i ,i �` `t ri f vl f. WorkClasSiArctiop Solat—Resldeetial Over,-10�KV' '" Arcadia,CA 91066-6021 7; `�.�r �r., u ,,s,.. - r x ;'I (626)574-5416 = ' t „'- _ Permit Status:Issued ARCADIA IssueUate 10/28/20191 Expiration: 04/25/2020 F Addr NO. Dir Prefix Street Name Street Suffix Unit City,State,Zip Parcel Number 210 W CAMINO REAL AVE Arcadia,CA 91007-6903 5785005002 Contacts _�._.. WANG,ZIYI R AND XUHONG Owner ENERGY PLUS Contractor 210 W CAMINO REAL AVE 1051 W COLUMBIA WAY 205,LANCASTER,CA 93534 (661)718-2070 736839 Description:ROOF MOUNT PV SYSTEM, 28 MODULES/MICRO i Valuation: $ 0.00 Tenant INVERTERS,NEW 100 AMP PV PANEL Total Sq Feet: 0.00 Plan Check U Plan N Fees Amount Payments Amount Paid Building Plan Check Fee Residential $50.00 Total Fees $324.72 Distribution Panel $16.48 Cash/Receipt N REC-02909-19 $324.72 Electrical Permit Issuance Fee $47.01 Amount Due: $0.00 Fire Plan Check Fee Residential $50.00 Inverters $77.78 ." culimiguPanels $82.45Solid Waste Management Fee 2 $1.00 Total: $324.72 4 CALLS FOR INSPECTIONS ,t v,4C- /Z L ! Request for inspection by telephone at 626-574-5450. Leave a message requesting the address,timeframe and what inspection item is needed. This permit/plan review expires by time limitation and becomes null and void if the work authorized by the permit is not commenced within 180 days from the date of issuance or if the permit is not obtained within 180 days from the date of plan submittal.This permit expires and becomes null and void if any work authorized by this permit is suspended or abandoned for 180 consecutive days or if no progressive work has been verified by a City of Arcadia building inspector for a period of 180 consecutive days. -4 October 28, 2019 Issued By: Date October 28,2019 Page 1 of 1 of A• 14 .kyr stvy tt r r +" I' PERMIT/PLAN REVIEW APPLICATION 0 Art Fa o 4-e,, Development Services Department,240 West Huntington Drive,Post Office Box 60021 0aairy al Na Arcadia, CA 91066-6021, (626) 574-5416, Fax (626) 447-9173 City of Arcadia *71 LICENSED CONTRACTOR'S DECLARATION WORKERS'COMPENSATION DECLARATION illi I hereby affirm under penalty of perjury that I am licensed under provisions of I hereby affirm under penalty of perjury one of the following: Chapter 9(commencing with Section 7000,of Division 3 of the Business and Professions Code,and my license is in full force and effect. I have and will maintain a certificate of consent to self-insure for workers' License ClassS..-1 U License No.7'j(,�i �l� Exp. Date /ZO/2.d compensation, as provided for by Section 3700 of the Labor Code, for the Signature of Contractor ( rt / performance of the work for which this permit is issued. OWNER-BUILDER D LARATION I have and will maintain workers'compensation insurance,as required by Section ❑ I hereby affirm under penalty of perjury that I am exempt from the Contractors 3700 of the Labor Code,for the ens performance of the work for which this pemvt License Law for the following reason(Section 7031.5,Business and Professions is issued.My workers'compensation insurance carrier and policy numbers are: Code.Any city or county which requires a permit to construct,alter,improve, Carrier demolish,or repair any structure,prior to its issuance,also required the applicant 1 P for such permit to file a signed statement that he or she is licensed pursuant to the Policy Number otel provisions of the Contractors License Law(Chapter 9(commencing with Section s section need not be completed if the permit is for one hundred dollars or less) 7000)of Division 3 of the Business and Professions Code)or that he or she is t I c that in the performance of the work for which this unit is issued,I shall exempt there from and the basis for the alleged exemption. Any violation of ❑ -1 ° Pe Section 7031.5 by any applicant for a permit subjects thea applicant to a civil of employ any person in any manner so as to become subject to the workers' penalty of not more than five hundred dollars($500)): PP compensation Laws of California,and agree that if I should become subject to the iorkers'compensation provisions of Section 3700 of the Labor Code,I shall fp{rthwith comply l with those provisions. 0 I, as owner of the property, or my employees with wages as their sole I compensation,will do the work,and the structure is not intended or offered for I(� .! sale(Section 7044,Business and Professions Code:The Contractors License Date 1/`L J I `'I Signature 6 / Law does not apply to an owner of property who builds or improves thereon, or who does such work himself or herself or through his or her own . . employees,provided that such improvements are not intended or offered for WARNING: Failure to secure Workers'Compensation coverage is unlawful, sale.If,however,the building or improvement is sold within one(1)year of ' and shall subject an employer to criminal penalties and civil fines up to one completion,the owner-builder will have the burden of proving that he or she hundred thousand dollars($100,000),in addition to the cost of compensation, did not build or improve for the purpose of sale). damages as provided for in Section 3706 of the Labor Code, interest, and attorney's fees. ❑I, as owner of the property, am exclusively contracting with licensed contractors to construct the project(Section 7044,Business and Professions Code:The Contractors License Law does not apply to an owner of property CONSTRUCTION LENDING AGENCY who builds or improves thereon,and who contracts for such projects with a I hereby affirm under penalty of perjury that there is a construction lending agency contractor(s)licensed pursuant to the Contractors License Law). for the performance of the work for which this permit is issued (Section 3097, Civil Code). ❑ I am exempt under Section 7044,Business and Professions Code,for this reason: Lender's Name Date Signature Lender's Address IMPORTANT: APPLICATION IS HEREBY MADE TO THE BUILDING OFFICIAL FOR A PERMIT SUBJECT TO THE CONDITIONS AND RESTRICTIONS SET FORTH ON THIS APPLICATION AND THE FOLLOWING: 1. The City's approved plans and permit inspection card must remain on the job site for use by City inspection personnel. 2. Final inspection of the work authorized by this permit is required.A Certificate of Occupancy must be obtained prior to use and occupancy of new buildings and structures. 3. Per South Coast Air Quality Management District(AQMD)regulations,renovation and remodeling work that results in the removal,stripping,or alaring of asbestos containing materials requires an asbestos survey and removal prior to disturbing the asbestos.Please contact AQMD at(909)396-2000 far further information. 1 .c7 -Ntme a.n (ct 5 4-;I r v Title PRINT NAME certify that I have read this application and state that the above information is correct and that I am the owner or duly authorized agent of the owner. agree to comply with all City ordinances and State Laws relating to building construction. I hereby authorize representatives of the City of rcadia to enter upon the above-mentioned property for inspection purposes. Stnature Date J /2-e / I el Table of Contents: Project Notes: \ -- 1'�t PV_1 Page S Description 1. Two story,curved tile ' Fy ; 2. Roof solar modulee consists of 2"x 4"rafters Q 24"O.C.with a max top chord span of 6', — 4 'r 11,620 kW DC PV-1 Site Plan — :. 1, 3. Total solar square footage of � ,..-11r•---.,.......22.7_ PV-2 Labels,Signage 4. ':--, 9;•fe,.; - ' —\}. 28-SunPower SPR-A415-G- 4` �,] . ' I 'ti N.N. AC Modules[SL PV-3 Single Line Diagram - J i :1 Fr sem` te- 1] PV-4 Detailed Electrical Plan I Cl \\, /,,.., , 1` ' h. 28-SunPower SPWR-A4 Mi- PV-5 Material Data Sheets-Modules The proposed project Is designed to meet the following elechkaland building codes: _ )^rtl99C~ - 1 "' .: croinverters[SL 1] 2016 CA Residential Code 2016 CA Plumbing Code ._._T iI � /__ ! PV-6 Material Data Sheets-Rackings 2016 CA Mechanical Code 2016 CA Energy Code ° `� >a —'�' --y- '` u 2016 CA Electrical Code 2016 City of LA Fire Code - - PV-7-13 R`e "'"'P1oei4ee0""s' .wxru.,mrvuuwnn+�<.c•e.eun, 2016 CA Green Code 2017 City of LA Electrical Code - 2014 National Electdcal Code 2016 Building Energy Efficiency Standards ^'"" t'— -- � t i `. /II \ t-`!,'. — - ' ' N Camino Real Ave. Construction Notes: 43 a w 6 . :.grey -r 1.All conduit,fittings,boxes comply with NEC 314.15A. , o 4 �'e l' 'I. - I Electrical equipment shall be listed by a City of Los Angeles rec- R w `R 1 t , l�l�r��t� /T�t1,y1 t t 1�tjl1� - ognized electrical testing laboratory or approved by the cd o E s 1t 'tll lit ofp'ztif�Y.l1 ��'1'!/jt 1�l f f depart- ment. eo o^ p'� _ "�t, 1 r f�i °rlf4 r ���i/l 'tl]�t{'(7 �tnWr 2.All equipment shall be installed in accordance with the 2 E(I6 w r c l t'IF ]nl rt ff/l --,:370.1071. I r t ryif i 7 :rh pr l , manufacturers installation instructions. V V U a - NV ii t I t,Trl'i( t 'er 11',(1trR1?s' ' ^1 ° ''Eo ro 1 r �F�rti'�1�°fir r _° 11I°t1• ^�` tl 1 3.All outdoor equipment shall be rain tight with minimum 3 u to 4" el ,�:' 1nr• ip ' t'I/i;1il l'• p I NEMA-3R rating. x -c. '•N r c111�i1 d'ti 0 Glace 4.All locations are approximate and require field verification. j r irtr' �prtf °ti r`�'-' ,l Z -11 5.PV array shall not cover any mechanical or plumbing vents. F !t t'Lx z. z,r Jt§ zt, I __ 6.PV array shall not exceed maximum roof height or 18"above fa ;, I tjf� '•f4.11( '1f a--- e 1 roof surface at any point. { J ,-2 1f"1, �' • �ri(I't" %VECTDR 1 I I iipwu�:tt i Il ' •,i:'Ioii e n a n e a n a 7.All interior and exterior conduit,enclosures,raceways, cable 1 '� - 11 ,, —... .eA,..::: assemblies,junction boxes and disconnects that contain photo- , 1 � (t .. ,. .." I �j dt���j�,fJ 11�� 11• r ilrli-,�I)w. "^�^ ^ voltaic circuits shall be labeled with the words"Warning:Photo- x if, J , 1 _ r Contractor:ERIC WEDELL P � , I!� , e j '� voltaic Power Source"in accordance with the provisions set forth P,J ! 1f 1j11 r 11,i�tlp, .` /I '`4p05'PR in fire code 605.11.1 through 605.11.1.4.Such labeling shall be /ra II(1f.1•1111 1 1 i }} r , P located at 10 foot intervals,within 1 foot of turns,bends and ( �- L _ tP/: i!!� gill ' b , .` �* within I foot on either side of penetrations of roof/ceiling assem- __41, s' III 1144�,;.‘7. - '..`.i fr blies,walls or barriers as required by fire code 605.11.1.4. ".j it,'” 1 , 1,. t1i 1 4- Install Crew Lead:Brian Namm ' 'fl`,Ili#+' :t k• C k- 1e0FcnL4� S.Construction foreman to confirm final conduit runs with ''`� 7,.2 r.,, 1� Energy Plus Solar 1. {{�� C7-: 9E�'i� r' ' '; r I customer. 1051 W Columbia Way#205 pt _ nilfim1 10/17/2019 ' '-.44,-- �_. .` I VSE Project Number:113002-0112-191 Lancaster,CA 93534 i `v _- .:.1 ],. _' "=t'e r�p•".tezi ^ tifrot5r 9.All exposed conduit to be painted to match existing colors. 661-718-2070 wn ry x..,o""i..m.a w...m...m„m m. ,et' W., • ' ;bra m. 4"�=:«� *iiidle..e�.b License#736839 enoevrone Meewu•orn.a.en.eMem.e tw ; . �' n ..�ti�_ _i..-..-f ".e•^wm.,r.•e^•^ C-10 Exp.6/30/2021 NTS CTOR E rl G I rl EERS VSE Project Number:U3002.0112.191 October 17,2019 Energy Plus Solar 1051 W.Ave M#205 Lancaster,CA 93534 REFERENCE: Ziyi&Xuhong Wang Residence:210 West Camino Real Avenue,Arcadia,CA 91007 Solar Array Installation To Whom It May Concern: Per your request, we have reviewed the existing structure at the above referenced site. The purpose of our review was to determine the adequacy of the existing structure to support the proposed installation of solar panels on the roof as shown on the panel layout plan. Based upon our review,we conclude that the existing structure is adequate to support the proposed solar panel installation. Design Parameters Code:California Building Code,2016 Edition(2015 IBC) • Risk Category:II Design wind speed: 110 mph (3-sec gust)per ASCE 7-10Cr\s.01\ -�A • Wind exposure category: C cr N c�xcc` .• \ Ground snow load: 0 psf ;.;:i C`�ti�\�ct t°icS us\\���e • ii0S Seismic designcategory:rC c,tt\lt»t" 'T�.`� t ttotv�ty` t.'0 Seismic pc ,d acs \sto \ Existing Roof Structure ``tp`titp`\tvtt.�\`' •\�tv\s"�oO 4.:0\\t\ttln Roof structure:2x4 manufactured'frusses a( `24trl L�. �ttvtc ' ` k\v' `�t(tk ���N�• `` Roofing material:concrete tile'(round\"' tt\-tv\'• �.:6, t.apt\`\� ��a\tt\\\ �,vA\e\� Roof slope:25° p\\y\`\\\�ctt `ru\\\vt` t`\1`'tp:tQQ``\ttv�ttc�ttt Connection to Roof \``S\,ypvQt\\t��`ttt\• `1\,tt`\(t\N" Mounting connection:(I)5/16" lag screw w(t l\r.2.s"\�l)Pament into framing at max.72"O.C.along rails (2)rails per row of panels,panel height n��tttcegee&�`5'-6 " Conclusions Based upon our review,we conclude that the existing structure is adequate to support the proposed solar panel installation. In the area of the solar array,other live loads will not be present or will be greatly reduced(2016 CBC, Section 1607.12.5). The gravity loads and; thus, the stresses of the structural elements, in the area of the solar array are either decreased or increased by no more than 5%.Therefore,the requirements of Section 403.3 of the 2016 CEBC are met and the structure is permitted to remain unaltered. 651 W.Galena Park Blvd.,Ste. 101/Draper, UT 84020/T(801)990-1775/F(801)990-1776/www.vectorse.com • VSE Project Number: U3002.0112.191 %VECTOR Ziyi Xuhong Wang Residence 10/17/2019 E ri O I rt E E R S The solar array will be flush-mounted (no more than 6" above the roof surface) and parallel to the roof surface. Thus, we conclude that any additional wind loading on the structure related to the addition of the proposed solar array is negligible. The attached calculations verify the capacity of the connections of the solar array to the existing roof against wind(uplift), the governing load case. Regarding seismic loads, we conclude that any additional forces will be small. Conservatively neglecting the weight of existing wall materials,the installation of the solar panels represents an increase in the total weight (and resulting seismic load) of 4.6%. Because the increase in lateral forces is less than 10%, this addition meets the requirements of the exception in Section 403.4 of the 2016 CEBC. Thus the existing lateral force resisting system is permitted to remain unaltered. Limitations Installation of the solar panels must be performed in accordance with manufacturer recommendations. All work performed must be in accordance with accepted industry-wide methods and applicable safety standards. The contractor must notify Vector Structural Engineering,LLC should any damage, deterioration or discrepancies between the as-built condition of the structure and the condition described in this letter be found. Connections to existing roof framing must be staggered,except at array ends, so as not to overload any existing structural member. The use of solar panel support span tables provided by others is allowed only where the building type,site conditions,site-specific design parameters,and solar panel configuration match the description of the span tables.The design of the solar panel racking(mounts,rails, etc.),and electrical engineering is the responsibility of others. Waterproofing around the roof penetrations is the responsibility of others. Vector Structural Engineering assumes no responsibility for improper installation of the solar array. VECTOR STRUCTURAL ENGINEERING,LLC .�FESSIp Ita %%.%. PRe 0 ' y m s> mt. �3 q�OFCAUF� 10/17/2019 Jacob Proctor,P.E. CA License:70567-Expires:06/30/2021 Project Engineer Enclosures JSP/ris 651 W.Galena Park Blvd.,Ste. 101/Draper, UT 84020/T(801)990-1775/F(801)990-1776/www.vectorse.com % / E C T O R JOB NO.: U3002.0112.191 SUBJECT: WIND PRESSURE E rl 0 1 rl E E R S PROJECT: Ziyi &Xuhong Wang Residence Components and Cladding Wind Calculations Label: Solar Panel Array Note: Calculations per ASCE 7-10 SITE-SPECIFIC WIND PARAMETERS: Basic Wind Speed [mph]: 110 Notes: Exposure Category: C Risk Category: II ADDITIONAL INPUT&CALCULATIONS: Height of Roof, h [ft]: 15`-f(Approximate) Comp/Cladding Location: Gable/Hip Roofs 7°<B<27° Hip? No Enclosure Classification: Enclosed Buildings Zone 1 GCP: 0.9 Figure 30.4-26 (enter largest abs. value) Zone 2 GCP: 1.7 (enter largest abs. value) Zone 3 GCP: 2.6 (enter largest abs. value) a: 9.5 Table 26.9-1 zg [ft]: 900 Table 26.9-1 Kb: 0.85 Table 30.3-1 Kai: 1 Equation 26.8-1 Kd: 0.85 Table 26.6-1 Velocity Pressure, ch, [psf]: 22.4 Equation 30.3-1 GCP;: 0 Table 26.11-1 PRESSURES: p=gi,KGCP)—(GCp,) Equation 30.9-1 Zone 1, p [psf]: 20.1 psf(1.0 W, Interior Zones*) Zone 2, p [psf]: 38.0 psf(1.0 W, End Zones*) Zone 3, p [psf]: 58.1 psf(1.0 W, Corner Zones*within a) (a= 3 ft) • • �/ ECTCR JOB N : 0112.191 SUBJECT: SEISM : SEISMIC LOADS E n O I rl E E R S PROJECT: Ziyi &Xuhong Wang Residence COMPARE WIND&SEISMIC LOADS FOR CONNECTION (1 Sq. Ft. Section) Wind Load, W: Wind pressure, p: 12.1 psf(Zone 1: 0.6 W from wind pressure calculation) Height, h: 1.0 ft Width,w: 1.0 ft Fpe,p: 12.1 lb(Uplift) Wind Controls Connection Design Seismic Load, E: Risk category: II Fa: 1.0 Seismic Design Category: D Fv: 1.5 Ip: 1.00 SMS: 2.170 Site Class: D SM1: 1.214 Rp: 1.5 SDS: 1.447 Ss: 2.170 SD1: 0.809 Si: 0.809 ap: 1 0.7* Fp,min: 0.911 lb Z: 1.0 ft 0.7* Fp,max: 4.861 lb h: 1.0 ft 0.7* Fp,vert: 0.608 lb zlh: 1.0 0.7* Fp,long: . 2.430 lb 0.7*Fp,perp: 1.578 lb(uplift) CHECK INCREASE IN OVERALL SEISMIC LOADS SEISMIC: Estimated Roof Dead Load 21.3 psf Solar Dead Load 3.0 psf Total Dead Load 22.3 psf % Coverage 33% Addt'I Seismic Weight 4.6% Conservatively neglecting the weight of existing wall materials, the installation of the solar panels represents an increase in the total weight(and resulting seismic load)of 4.6%. Because the increase is less than 10%,this addition meets the requirements of the exception in Section 403.4 of the 2016 CEBC.Thus the existing structure is permitted to remain unaltered. VECTORJOB NO.: U3002.0112.191 SUBJECT: CONNECTION E n s I fl E E R S PROJECT: Ziyi &Xuhong Wang Residence Lag Screw Connection Capacity: Demand: Lag Screw Size [in]: 5/16 Cd: 1.6 NDS Table 2.3.2 Pressure Max Max. Trib. Max. Uplift W Embedment' [in]: 2.5 (0.6 Wind) Tributary Area Force (lbs) Grade: SPF (G = 0.42) Zone (psf) Width (ft) ( ) Capacity[lbs/in]: 205 NDS Table 12.2A 1 12.1 6.0 16.5 199 Number of Screws: _ 1 2 22.8 6.0 16.5 376 Prying Coefficient: 1.4 3 34.9 6.0 16.5 575 Total Capacity[lbs]: 586 Demand< Capacity: CONNECTION OKAY 1.Embedment is measured from the top of the framing member to the beginning of the tapered tip of the lag screw. Embedment in sheathing or other material is not effective.The length of the tapered tip is not part of the embedment length. 2.'Max.Trib Area'is the product of the'Max.Tributary Width'(along the rails)and 1/2 the panel width/height (perpendicular to the rails). %VECTORJOB NO.: U3002.0112.191 SUBJECT: GRAVITY LOADS Eno I n E E R 8 PROJECT: Ziyi &Xuhong Wang Residence CALCULATE ESTIMATED GRAVITY LOADS Increase due to Original ROOF DEAD LOAD (D) pitch loading Roof Pitch/12 5.6 Concrete Tile (Round) 13.2 1.10 12.0 psf 1/2" Plywood 1.1 1.10 1.0 psf Framing 3.0 psf Insulation 0.5 psf 1/2" Gypsum Clg. 2.0 psf M, E & Misc 1.5 psf DL 21 psf PV Array DL 3 psf ROOF LIVE LOAD (Lr) Existing Design Roof Live Load [psf] 20 ASCE 7-10,Table 4-1 Roof Live Load With PV Array[psf] 0 2016 CBC, Section 1607.12.5 w/Solar Panel SNOW LOAD (S): Existing Array Roof Slope [x:12]: 5.6 5.6 Roof Slope [°]: 25 25 Snow Ground Load, p9 [psf]: 0 0 ASCE 7-10, Section 7.2 Terrain Category: C C .ASCE 7-10, Table 7-2 Exposure of Roof: Fully Exposed Fully Exposed ASCE 7-10, Table 7-2 Exposure Factor, Ce: 0.9 0.9 ASCE 7-10,Table 7-2 Thermal Factor, Cf: 1.1 1.1 ASCE 7-10,Table 7-3 Risk Category: II II . ASCE 7-10, Table 1.5-1 Importance Factor, Is: 1.0 1.0 ASCE 7-10,Table 1.5-2 Flat Roof Snow Load, pf[psf]: 0 0 ASCE 7-10, Equation 7.3-1 Minimum Roof Snow Load, pm [psf]: 0 0 ASCE 7-10, Section 7.3.4 Unobstructed Slippery Surface? No No ASCE 7-10, Section 7.4 Slope Factor Figure: _ Figure 7-2b Figure 7-2b _ASCE 7-10, Section 7.4 Roof Slope Factor, C5: 1.00 1.00 ASCE 7-10, Figure 7-2 Sloped Roof Snow Load, ps [psf]: 0 0 ASCE 7-10, Equation 7.4-1 Design Snow Load, S [psf]: 0 0 • ' • %VEC_1IbCRLOAD JOB NO.: 0112.191 SUBJECT: LOAD COMPARISON E rl O I rl E E R S PROJECT: Ziyi &Xuhong Wang Residence Summary of Loads Existing With PV Array D [psf] 21 24 Lr[psf] 20 0 S [psf] 0 0 Maximum Gravity Loads: Existing With PV Array (D+Lr)/Cd [psf] 33 27 _ASCE 7-10,Section 2.4.1 (D+5)/Cd [psf] 24 27 ASCE 7-10,Section 2.4.1 (Cd=Load Duration Factor=0.9 for D,1.15 for 5,and 1.25 for Lr) Maximum Gravity Load [psf]: 33 27 • Ratio Proposed Loading to Current Loading: 82% OK The gravity loads and;thus,the stresses of the structural elements,in the area of the solar array are either decreased or increased by no more than 5%.Therefore,the requirements of Section 403.3 of the 2016 CEBC are met and the structure is permitted to remain unaltered.