HomeMy WebLinkAboutUntitled r
o c 1 City of Arcadia, CA • . Permit NO SOLR-19 2232'.
Development Services Department Permit Type Solar
240 West Huntington Drive,Post Office Box 60021
e t lc '=2i 'Arcadia,CA 910fi6-6021 -,.. W C o l cation Solar-ResldentiallOver 10_1(V.
(626)574-5416 - ---,. - - Permit Status:Issued
ARCADIA issue Date 11/04/2019YI ~Expiration: 05/02/2020
Addr NO. Dir Prefix Street Name Street Suffix Unit City,State,Zip Parcel Number
1200 GREENFIELD AVE Arcadia,CA 91006-4147 5781008019
Contacts
Tung Phan Owner ECOSOLAR USA ELECTRICAL LLC Contractor I
. 1200 Greenfield AVE 13962 SEABOARD CIR,GARDEN GROVE,92843
(714)265-9077 1045300
Description:ROOF MOUNTED PV SYSTEM, 33 MODULES/MICRO Valuation: $ 0.00 Tenant
INVERTERS,NEW 125 AMP LOAD CENTER,NEW 225 AMP MAIN!
SERVICE PANEL (200 MCB,60 AMP PV BREAKER) Total Sq Feet: 0.00 Plan Check ft Plan fl
Fees Amount Payments _ Amount Paid
Building Plan Check Fee Residential $50.00 Total Fees $341.20
Distribution Panel $16.48 Cash/Receipt it REC-02986-19 $341.20
Electrical Permit Issuance Fee $47.01
Fire Plan Check Fee Residential $50.00 Amount Due: $0.00
Inverters $77.78
Panels $82.45
Residential Services up to 400 amps $16.48
Solid Waste Management Fee 2 $1.00 I COI/Flint
Total: $341.20
/� r q dry
CALLS FOR INSPECTIONS
F/441.4_`�441.L �Z-7 / `/y^'y Request for inspection by telephone at 626-574-5450. Leave a message
(7 ��� G/ requesting the address,timeframe and what inspection item is needed.
gecEi VED Ssse$F aE rc.rv2 AFFicylun -
This permit/plan review expires by time limitation and becomes null and
void if the work authorized by the permit is not commenced within 180 days
from the date of issuance or if the permit is not obtained within 180 days
from the date of plan submittal.This permit expires and becomes null and
void if any work authorized by this permit is suspended or abandoned for 180
consecutive days or if no progressive work has been verified by a City of
Arcadia building inspector for a period of 180 consecutive days.
•
November 04, 2019
Issued By: Date
November 04,2019 Page 1 of 1
t
,7 PERMIT/PLAN REVIEW APPLICATION
-.101- . Development Services Department,240 West Huntington Drive, Post Office Box 60021
°%„,,,,,,,% Arcadia, CA 91066-6021, (626) 574-5416,Fax (626) 447-9173
City of
Arcadia
LICENSED CONTRACTOR'S DECLARATION WORKERS'COMPENSATION DECLARATION
I hereby affirm under penalty of perjury that I am licensed under provisions of I hereby affirm under penalty of perjury one of the following:
Chapter 9(commencing with Section 7000,of Division 3 of the Business and
Professions Code,and my license is in full force and effect
License Class C In
Signature of Contractor—
❑ I have and will maintain a certificate of consent to self-insure for workers'
License No. ��k r13 Exp. Date compensation, as provided for by Section 3700 of the Labor Code, for the
performance of the work for which this permit is issued.
-—
OWNER-BUILDER DECLARATION I have and will maintain workers'compensation insurance,as required by Section
❑ I hereby affirm under penalty of perjury that I am exempt from the Contractors 3700 of he Labor Code,for he perfo mance of the work for wh ch his permit
License Law for the following reason(Section 7031.5,Business and Professions is issued.
I Mytlworkers'compenFsation insurance carrier and policy numbers are:
Code.Any city or county which requires a permit to construct,alter,improve, Carrier 1 1 4 S a C(n �1 I r Mi nn° Onfill ).p t1
demolish,or repair any structure,prior to its issuance,also required the applicant FT / Q.q fl 2 1 7
for such permit to file a signed statement that he or she is licensed pursuant to the Policy Number "`PPP 7 d J
provisions of the Contractors License Law(Chapter 9(commencing with Section (This section need not be completed if the permit is for one hundred dollars or less)
7000)of Division 3 of the Business and Professions Code)or that he or she is
exempt there from and the basis for the alleged exemption. Any violation of I certify that in the performance of the work for which this permit is issued,I shall
Section 7031.5 by any applicant for a permit subjects the applicant to a civil not employ any person in any manner so as to become subject to the workers'
penalty of not more than five hundred dollars($500)): compensation Laws of California,and agree that if I should become subject to the
workers'compensation provisions of Section 3700 of the Labor C de,I shall
❑I, as owner of the property, or my employees with wages as their sole forthwith comply with those provisions.
compensation,will do the work,and the structure is not intended or offered for Date il I(\I-licsi 0 I q Signatuso
sale(Section 7044,Business and Professions Code:The Contractors License
Law does not apply to an owner of property who builds or improves thereon,
or who does such work himself or herself or through his or her own -.
employees,provided that such improvements are not intended or offered for WARNING: Failure to secure Workers'Compensation coverage is unlawful,
sale.If,however,the building or improvement is sold within one(1)year of and shall subject an employer to criminal penalties and civil fines up to one
completion,the owner-builder will have the burden of proving that he or she hundred thousand dollars($100,000),in addition to the cost of compensation,
did not build or improve for the purpose of sale). damages as provided for in Section 3706 of the Labor Code, interest, and
attorney's fees.
0 I, as owner of the property, am exclusively contracting with licensed
contractors to construct the project(Section 7044, Business and Professions CONSTRUCTION LENDING AGENCY
Code:The Contractors License Law does not apply to an owner of property
who builds or improves thereon,and who contracts for such projects with a I hereby affirm under penalty of perjury that there is a construction lending agency
contractor(s)licensed pursuant to the Contractors License Law). for the performance of the work for which this permit is issued (Section 3097,
Civil Code).
❑ I am exempt under Section 7044,Business and Professions Code,for this reason:
Lender's Name
Date Signature Lender's Address •
IMPORTANT:APPLICATION IS HEREBY MADE TO THE BUILDING OFFICIAL FOR A PERMIT SUBJECT TO THE CONDITIONS AND
RESTRICTIONS SET FORTH ON THIS APPLICATION AND THE FOLLOWING:
I. The City's approved plans and permit inspection card must remain on the job site for use by City inspection personnel.
2. Final inspection of the work authorized by this permit is required.A Certificate of Occupancy must be obtained prior to use and occupancy of new buildings
and structures.
3. Per South Coast Air Quality Management District(AQMD)regulations,renovation and remodeling work that results in the removal,stripping,or altering
of asbestos containing materials requires an asbestos survey and removal prior to disturbing the asbestos.Please contact AQMD at(909)396-2000 for
further information. tt �
Name V` E�0 Title f'f(1I0(I IR(elf\ n.7 vitt
PRINT NAME
I certify that I have read this application and state that the above information is correct and that I am the owner or duly authorized agent of the owner.
I agree to comply with all City ordinances and State Laws relating to building construction. I hereby authorize representatives of the City of
Arcadia to enter upon the above-mentioned property."inspection purposes. I /I
Si nature Date 1j \ �Ik ( (N 0
7
itdT
f
4
• twit:,J.'vai i s
w
ca/t5:^1`1c�
AFFIDAVIT SELF-CERTIFICATION
FOR COMPLIANCE OF SMOKE ALARMS
AND CARBON MONOXIDE ALARMS
n Aim-
Property Address: ) .2.0 D 4-120-(2.41e
Permit Number: cnt R -1 9-27 3 Z
Brief Job Description:
Number of smoke alarms installed: if
Number of carbon monoxide alarms installed:
When alterations, repairs or additions requiring a permit occur, or sleeping rooms are created,
Smoke alarms shall be installed in each sleeping room, and outside each separate
sleeping area in the immediate vicinity of the bedrooms, and on each additional story of the
dwelling, including basements and habitable attics as required by Section R314 of the 2016
California Residential Code (CRC) and California Health and Safety Code Section 13113.7.
For dwellings or sleeping units containing fuel burning appliances or having attached
garages, carbon monoxide alarms shall be installed outside each separate sleeping
area in the immediate vicinity of the bedrooms, and on each additional story of the
dwelling, including basements as required by Section R315 of the of the 2016 California
Residential Code (CRC).
Multi-purpose alarms (combination carbon monoxide and smoke alarms) may be used.
All alarms shall comply with requirements for listing and approval by the Office of the State Fire
Marshal. http://osfm.fire.ca.qov/licensinglistingsllicenselistinq bml searchcotest.php
As owner of the above referenced property, I hereby certify that the smoke alarms and carbon
monoxide alarms have been installed in accordance with the manufacturer's instructions and in
compliance with the code sections referenced above.
I declare under penalty of perjury that the foregoing is true and correct, and that this
declaration was executed on (Date) at Arcadia, California.
Owner's Name (printed/typed): 1 I. A ID A A.
Signature of Owner: �. _ _.. ► _
a
This affidavit must be returned to the City of Arcadia inspector prior to final inspection
0
Sr' i , _ .11 ,' ' ', rCtt. _ • ', FJOkOXIr t. ' `•7 •C.& I ors, -•
Guest Room _ �Bathroun
I Storage
F. G C1
•
II Family Roam
•ono
NMLs-"--''''''.--.....-" ' NM
- - Garage
FIRST FLOOR PLAN
gi= SMOKE ALARM V = CARBON MONOXIDE ALARM
I 1 rThstrBath
Dining Room Kitchen
-Bildt
0 -
Hall E) Closet
m I Closet Closet
Family Room ® ®
Bedroom Bedroom
—— ��qq SECOND FLOOR PLAN
0=SMOKE ALARM fl i a CARBON MONOXIDE ALARM
1
r
10/7/2019
e ` -•�,
• ,►,l►►t► yours . rplans.com
two ► ENGINEERING SOLUTIONS FOR ALL YOUR SOLAR NEEDS
Structural Calculations for
SOLAR POWER SYSTEM CONNECTION.CHECK AT: •
1200 Greenfield Ave .
Arcadia,CA 91006 -,-.1,--.'"'
Job: Giatung Phan tt
.,_ CtC Mil
;c`-::t';' , nv ,. t trtt',\�_ltt
Prepared For: °eq C\T` r eruct"tlt.(
_ _ �e\Cint)1.11' 0,i 1,\•r'1t1 :11'
t,ctapt
Permit Runner ',` r\' i "."1
\tit 11c iottS
(619)933-4868 Ckl„. rut -
�t,i CA l,t ptatt\ ntt n„ch•tti .{'tn, .\44,0 to
tl tltl\l lt,t,.., t 1`p.,t
• on you.'so,% itV'a;le c`.t,V. - . the trc111r:;1i"t a t tl p
2,0
. Design Criteria . .outift},l ul OW,l l �\an aVV,T"t.•. `` ok ..A.,',.. ,.,.ti
li or 19
ll
I- Code: CALIFORNIA BLDG CODE 2016/ASCE 7-19=.;•i="` ''t\ tl
2-Wind: 110 MPH,Exposure:C ,tt ,•t;; tstt`
3 -Wood Species:DF-L No.2(SG= 0.5)
Notice:Use restrictions of these calculations.
The attached Calculations are valid only when bearing original signature hereon.
Contractor/Client to verify existing dimensions/conditions prior to construction
&solar racking is installed per manufacturer span requirements.
The use of these calculations is solely intended for the above mentioned project.
ke0 4‘
E? cis-
cc No. C70784 a
,I� p.NI i t- `
`r”
sr CP/It $t-
9TP of CAItFdi` ..
_ _ 1-844-PV ELITE!info@yoursolarplans.com -
3000 E.Birch Street Suite 2011 Brea CA 92821
WIND LOADING ANALYSIS - Roof Components and Cladding .
Per ASCE 7-10 Code for Bldgs.of Any Height with Gable Roof 0 <=45°or Monoslope Roof 8 <=3°
Using Part 1 &3: Analytical Procedure (Section 30.4&30.6)
Job Name: Giatung Phan Subject:
Job Number: Originator: I Checker:
Input Data:
Wind Speed,V= 110 mph (Wind Map, Figure 26.5-1A-C)
3ldg. Classification = II (Table 1-1 Occupancy Category)
' Exposure Category= C (Sect. 26.7) B
Ridge Height, hr= 19.53 ft. (hr>= he)
Eave Height, he= 8:00 ft. (he<= hr) •
Building Width = 71:00 ft. (Normal to Building Ridge)
Building Length= 41.00 ft. (Parallel to Building Ridge) I L
Roof Type= Gable (Gable or Monoslope)
Topo. Factor, Kzt= 1.00 (Sect. 26.8& Figure 26.8-1) Plan
Direct. Factor, Kd= 0.85 (Table 26.6)
Enclosed? (Y/N) Y (Sect. 28.6-1 & Figure 26.11-1)
Hurricane Region? N
A
Component Name= Fastener (Purlin, Joist, Decking, or Fastener) hr
Effective Area,Ae= 662 ft.A2 (Area Tributary to C&C) he
Overhangs?(Y/N) -N (if used, overhangs on all sides)
L
Resulting Parameters and Coefficients: Elevation
Roof Angle, 8 = 18.00 deg.
Mean Roof Ht., h = 15.00 ft. (h = (hr+he)/2, for roof angle.>10 deg.)
Roof External Pressure Coefficients, GCp:
3Cp Zone 1-3 Pos. = 0.30 (Fig. 30.4-2A, 30.4-2B, and 30.4-2C)
GCp Zone 1 Neg. = -0.80 (Fig. 30.4-2A, 30.4-2B, and 30.4-2C)
GCp Zone 2 Neg. = -1.20 (Fig. 30.4-2A, 30.4-2B, and 30.4-2C)
GCp Zone 3 Neg. = -2.00 (Fig. 30.4-2A, 30.4-2B, and 30.4-2C)
Positive & Negative Internal Pressure Coefficients, GCpi (Figure 26.11-1):
+GCpi Coef. = 0.18 (positive internal pressure)
-GCpi Coef. = -0.18 (negative internal pressure)
If z <= 15 then: Kz=2.01*(15/zg)^(2/a) , If z> 15 then: Kz=2.01*(zlzg)^(2/a) (Table 30.3-1)
a= 9.50 (Table 26.9-1)
zg = 900 (Table 26.9-1)
Kh = 0.85 (Kh= Kz evaluated at z= h)
Velocity Pressure: qz= 0.00256*Kz*Kzt*Kd*VA2 (Sect. 30.3.2, Eq. 30.3-1)
qh = 22.35 psf qh = 0.00256*Kh*Kzt*Kd*V^2 (qz evaluated at z= h)
Design Net External Wind Pressures(Sect. 30.4 &30.6):
For h <=60 ft.: p= qh*((GCp)-(+/-GCpi)) (psf)
For h > 60 ft.: p= q*(GCp)-qi*(+/-GCpi) (psf)
where: q =qh for roof
qi= qh for roof(conservatively assumed per Sect. 30.6)
Wind Load Tabulation for Roof Components&Cladding
Component z Kh qh p= Net Design Pressures(psf)
(ft.) (psf) 'one 1,2,3 (+ Zone 1 (-) Zone 2 (-) Zone 3 (-)
Fastener 0 0.85 22.35 10.73 -21.90 -30.84 -48.72
15.00 0.85 22.35 10.73 -21.90 -30.84 -48.72
For z= hr 19.53 0.85 22.35 10.73 -21.90 -30.84 -48.72
MINN
For z= he: 8.00 0.85 22.35 10.73 -21.90 -30.84 -48.72
For z= h: 15.00 0.85 22.35 10.73 -21.90 -30.84 -48.72
Notes: 1. (+) and (-) signs signify wind pressures acting toward &away from respective surfaces.
2. Width of Zone 2 (edge), 'a'= 4.10 ft.
3. Width of Zone 3 (corner), 'a'= 4.10 ft.
4. For monoslope roofs with 0 <= 3 degrees, use Fig. 30.4-2A for'GCp'values with 'qh'.
5. For buildings with h > 60' and 0 > 10 degrees, use Fig. 30.6-1 for'GCpi'values with 'qh'.
6. For all buildings with overhangs, use Fig. 30.4-2B for'GCp'values per Sect. 30.10.
7. If a parapet>= 3' in height is provided around perimeter of roof with 0 <= 10 degrees,
Zone 3 shall be treated as Zone 2.
8. Per Code Section 30.2.2, the minimum wind load for C&C shall not be less than 16 psf.
9. Reference: a. ASCE 7-10, "Minimum Design Loads for Buildings and Other Structures".
b. "Guide to the Use of the Wind Load Provisions of ASCE 7-10"
by: Kishor C. Mehta and James M. Delahay(2004).
Roof Components and Cladding:
illii 11 -
._ 3_W__ _ _ - ,Ti.. © T. 0 o as i
,
1 I
9 I
V a 01 00000 Cr aocgaCi
t
F ,
l .
0 <=7 deg. 7 deg. < 0 <=27 deg. 27 deg.< 0 <=45 deg.
Roof Zones for Buildings with h a 60 ft.
(for Gable Roofs<=45°and Monoslope Roofs<= 3°)
, a ,
Q; o 10
, 1
, 1
J L
I 1
0.'7--©-_r a3 h
ROOF PLAN
Roof Zones for Buildings with h > 60 ft.
(for Gable Roofs a 10°and Monoslope Roofs <=3°)
•
Gravity Load Data'
Panel Data
Panel: ' EQUX-A400-WHT
Number of Modules: 33
•
Weight of PV Module 46.5 lbs •
PV Module Dimensions L= 72.2 in
W= 40.0 in
Roof Data
Roof Material: TILE
Roof Dead Load Qo= 17 psf
PV System Dead Load Op„= 3 psf
Framing Spacing sreof= 24.in
Linear Dead Load WD=(Qo+Qpv)*swot= 40 plf
Lag Screw Check Lumber: DF-L-No:2
Uplift Demand
•
Design Wind Pressure p= -30.8 psf(Zone 2)
Trib. Depth for Each Rail dp =U2= 3.01 ft
Trib. Depth for Each Rail bp„ =W/2= 1.67 ft
• Screw Anchor Spacing spy= 4.00 ft(max.)
Uplift Force on Each Screw, Portrait UL=(p+Qp„)*dpv*spy= -335 lbs(Upwards)
Uplift Force on Each Screw,Landscape Uw=(p+Qp5)*bp„*spv= -186 lbs(Upwards)
Design Uplift Force Pupiin=0.6*[Max(UL,UW)]= -201 lbs(Upwards)
Uplift Capacity
NDS 2015 Adjustment Factors •
Co= 1.6 CM= 1 Cf= 1 SG= 0.50 C„ Ceg, Cg, Cdl, CN are not appicable
Speicfic Gravity of Lumber SG= 0.50 NDS Supplement Table 4a
Diameter of Lag Screw D= 5116 in •
Withdraw Design fin 1800*SG"`*D36= 266 lbs/in NDS 201512.1-1
Depth of Embeddment Ip= 2.50 in
Total Nominal Withdrawal Value W=W*I p= 665 lbs
Withdrawal Design Vaule W=W*CD*CM*C,= 1064 lbs NDS 2015 Table 11.3.1
Demand-Capacity Ratio Pupllft/W = 0.19 < 1 (OKAw)
Beam/Top Chord Check Lumber DF-L No.2
Moment Demand
Span: 1 2 Orientation j It(ft) pi(lbs)
Lenght(ft) : 7.1 10 Portrait 1 3.8 -335
2 8.2 -335
3 9.9 -335
Linear Dead Load wd= 40 plf Portrait 4 14.2• -335
Wind Load, Portrait UL= -335 lbs
Wind Load, Landscape Uw= -186 lbs
#of Attachment per Rafter NA= 4
WdX2
M(X)=Rr(X— Pi@—l/)—
600 €
400 ..__' � .....
200
Fa -200 0 0-;— -0--? 410.0=�-15.0-',_ 20.0
-400
-600 I
Hi
Length x(ft)
Ma, Moment
Dead 496 lb-ft
Dead+Wind 565 lb-ft
Dead+Snow 496 lb-ft
Moment Capacity Framing Member Size 2x6 Lumber Grade: DF-L No.2
CM= 1 C1= 1 Cr 1.15 CF= 1.3 fb= 900 psi Ca,and C;are not applicable
Breadth b= 1.50 in
Depth d= 5.50 in
Section Modulus Sa =bd2/6= 7.56 ins
Bending Stress Capacity Fb= CM*C1*Cr*CF*fb= 1346 psi Table 4.3.1 NDS 2015 •
Co FL;=Cc*Fb Ma*S„ ASD Load Design Bending DCR
Dead 0.9 1211 psi 787 psi D 787 psi 0.65 OKAY
Dead+Wind 1.6 2153 psi 896 psi .6W+.6D 538 psi 0.25 OKAY
Dead+Snow 1.15 1547 psi 787 psi D+S 787 psi 0.51 OKAY
Deflection Limit E= 1600 ksi I= 20.80 in4
Transient Deflection 0.140 in
Transient Deflection Allowed 858 > 180 [OKAY]
Total Deflection 0.211 in
Total Deflection Allowed 569 > 120 [OKAY]
SEISMIC WEIGHT COMPARISON/ANALYSIS-(PER CBC 2016 Part 10 Chapter 4 Section 402.4)
PV System Weight
Module Model EQUX-A400-WHT
Panel Weight Wpanel= 46.5 lbs
Number of Panels Npv= 33
Total PV System Weight WPV=Wpanel'NPV= 1534.5 lbs
Existing Roof Weight
Roof Weight Qo= 17.0 psf
Building Length Lbund= 41 ft
Building Width Wbuild.= 71 ft
Roof Area Abuild= 2911 ft2
Building Perimeter Pbuild= 224 ft
Wall Height hr= 8 ft
Wall weight Qwall= 15 psf
Interior wall weight `tint= 10 psf
Roof Load Wnoor=Abuild*Qo= 49487 lbs
Wall Load Nwall= hr/2*Qwan*Pbuild +Abuild*Qint/2= 27995 lbs
Total Story Weight Wbuild=Moor+Wwau= 77482 lbs
Percentage Weight Increase WPv/Wbund= 1.98% < 10% OKAY