HomeMy WebLinkAboutUntitled /. City of Arcadia, CA " _r Permit NO.TI=18-1704 . �� Development Services Department Yet t-'I Permit Type:Tenant Improvement i• , 240 West Huntington Drive,Post Office Box 60021 +' ' Arcadia,CA 91066-6021 � � l r WorkG/assrfi'cggon:Tenant Improvement I�Vr (626)574-5416 —c Permit Status:Issued ARCADIA Issuepate:08/22/20191 Expiration: Addr NO. Dir Prefix Street Name Street Suffix Unit City,State,Zip Parcel Number 376 W Huntington DR Arcadia, CA 5775024912 Contacts AMERICAN RED CROSS Agent for owner ROY H Applicant (682)351-3165 (310)275-7774 April Carter Applicant (626)464-1911 Description:T.I.AMERICAN RED CROSS WITH EMP Valuation: $ 350,000.00 Tenant AMERICAN RED CROSS Total Sq Feet: 0.00 Plan Check#18-1704 Plan#111 . ,. .. ®m. Fees Amount Payments Amount Paid Accessibility Plan Check $287.53 Total Fees ,�/�' / fle $7,391.41 Accessiblity Building Permit $294.90 Cash/Receipt#REC-02214-19V"V 1404111t $4,125.54 Add/Alter Ducts $9.38 Cash/Receipt#REC-002322-2 $3,265.87 Building Issuing Fee $47.01 E' Building Permit Fees $2,949.00 Amount Due: 1e�� $0.00 Building Plan Review Fee $1,916.85 Cal Green Plan Check $191.691/- -n 7 Commercial T.I.Fire Plan Chk. $280.00 '��G a /� Compressor 3-5 Ton(3 to 15 hp) $68.34 Dishwasher $12.46 Distribution Panel $15.55 CALLS FOR INSPECTIONS Electrical Permit Issuance Fee $47.01 Request for inspection by telephone at 626-574-5450. Leave a message Energy Plan Review Fee $589.80 requesting the address,timeframe and what inspection item is needed. Floor Drain Fee $37.38 Furnace or Burner<=100,000 BTU $37.48 Green Building Standard $14.00 This permit/plan review expires by time limitation and becomes null and Kitchen Sink $24.92 void if the work authorized by the permit is not commenced within 180 days Light Fixtures $160.80 from the date of issuance or if the permit is not obtained within 180 days Mechanical Permit Issuance Fee $47.01 from the date of plan submittal.This permit expires and becomes null and Outlets-Receptacles&Switches $90.80 void if any work authorized by this permit is suspended or abandoned for 180 consecutive days or if no progressive work has been verified by a City of Plumbing Permit Issuance Fee $47.01 Arcadia building inspector for a period of 180 consecutive days. Total: $7,391.41 . lf I August 22, 2019 Issued By: Date August 22,2019 Page 1 of 1 cfr,]F 4Y,1'e It • 441 .-11; 1 PERMIT/PLAN REVIEW APPLICATION al . , e 10.' Development Services Department,240 West Huntington Drive,Post Office Box 60021 a' Arcadia, CA 91066-6021, (626) 574-5416,Fax (626) 447-9173 City of Arcadia LICENSED CONTRACTOR'S DECLARATION WORKERS'COMPENSATION DECLARATION ❑ I hereby affirm under penalty of perjury that I am licensed under provisions of I hereby affirm under penalty of perjury one of the following: Chapter 9(commencing with Section 7000,of Division 3 of the Business and Professions Code,and my license is in full force and effect. ❑ I have and will maintain a certificate of consent to self-insure for workers' License Class License No. Exp. Date compensation, as provided for by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. Signature of Contractor OWNER-BUILDER DECLARATION ❑ I have and will maintain workers'compensation insurance,as required by Section ❑ I hereby affirm under penalty of perjury that I am exempt from the Contractors 3700 of the Labor Code,for the performance of the work for which this permit License Law for the following reason(Section 7031.5,Business and Professions is issued.My workers'compensation insurance carrier and policy numbers are: Code.Any city or county which requires a permit to construct,alter,improve, Carrier demolish,or repair any structure,prior to its issuance,also required the applicant for such permit to file a signed statement that he or she is licensed pursuant to the Policy Number provisions of the Contractors License Law(Chapter 9(commencing with Section (This section need not be completed if the permit is for one hundred dollars or less) 7000)of Division 3 of the Business and Professions Code)or that he or she is exempt there from and the basis for the alleged exemption. Any violation of 0 I certify that in the performance of the work for which this permit is issued,I shall Section 7031.5 by any applicant for a permit subjects the applicant to a civil not employ any person in any manner so as to become subject to the workers' penalty of not more than five hundred dollars($500)): compensation Laws of California,and agree that if I should become subject to the workers'compensation provisions of Section 3700 of the Labor Code,I shall ❑I, as owner of the property, or my employees with wages as their sole forthwith comply with those provisions. compensation,will do the work,and the structure is not intended or offered for sale(Section 7044,Business and Professions Code:The Contractors License Date Signature Law does not apply to an owner of property who builds or improves thereon, or who does such work himself or herself or through his or her own employees,provided that such improvements are not intended or offered for WARNING: Failure to secure Workers'Compensation coverage is unlawful, sale.If,however,the building or improvement is sold within one(1)year of and shall subject an employer to criminal penalties and civil fines up to one completion,the owner-builder will have the burden of proving that he or she hundred thousand dollars($100,000),in addition to the cost of compensation, did not build or improve for the purpose of sale). damages as provided for in Section 3706 of the Labor Code, interest, and attorney's fees. I, as owner of the property, am exclusively contracting with licensed - contractors to construct the project(Section 7044,Business and Professions Code:The Contractors License Law does not apply to an owner of property CONSTRUCTION LENDING AGENCY who builds or improves thereon, and who contracts for such projects with a I hereby affirm under penalty of perjury that there is a construction lending agency contractors)licensed pursuant to the Contractors License La ). for the performance of the work for which this permit is issued (Section 3097, Civil Code). ❑ I am exempt under Section 7044,Business an.% si ns Code, •s this reason: (%/��/ , Lender's Name Date C >�0a/h Signature / ' ,,, 4 Lender's Address I f IMPORTANT: APPLICATION IS HEREBY MADE TO THE BUILDING OFFICIAL FOR A PERMIT SUBJECT TO THE CONDITIONS AND RESTRICTIONS SET FORTH ON THIS APPLICATION AND THE FOLLOWING: I. The City's approved plans and permit inspection card must remain on the job site for use by City inspection personnel. 2. Final inspection of the work authorized by this permit is required.A Certificate of Occupancy must be obtained prior to use and occupancy of new buildings and structures. 3. Per South Coast Air Quality Management District(AQMD)regulations,renovation and remodeling work that results in the removal,stripping,or altering of asbestos containing materials requires an asbestos survey and removal prior to disturbing the asbestos.Please contact AQMD at(909) 396-2000 for further informs Name [(.' \1 1 ( / the I-e u `C• his,. PRINT NAME I certify that I have re 'cation • I ; state that the above information is torr ct and that I am the owner or duly authorized agent of the owner. I agree to comply t . . ' and State Laws relating to building construction. I hereby authorize representatives of the City of Arcadia to enter u I 1 . ;ove-•.en I ; :, property for inspection purposes. /�n(� '//�1' `//�,�y� ignature '/ � ate v V��� 1 NOTES Olin, In lip In 1. maim 'in r In 16 Id, 'lv/4na&TT/I Rep (gess 100. Setbacks 210. Under fir.rbldg.drain ga-19 ry v 101. Rough grade 211. Copper underslab l�Z .� 102. Figs.&forms •41 Q W1 212. Rou.h.lumbin• � L44- a O046-. 103. Pre-slab (pfd • ED) 213. Rough gas ' / 104. Floor joists 214. Shower pan ECIcr€eC 6/{ W1 CS Waif- 105. Steel 215. Water heater fZA4v G `44YG+ 106. Grout lift 216. Roof drains _ // '/ 107. Shear nailin 217. Buildin.sewer -2641 �i�-w' / y'r`-f�•.4" C �uG,7s 108. Diaph nailing 218. Water service 109. Roof nailing 219. Final gas 110. Framing 220. Fixtures 111. 0cc/Area Sept.Wall _ _ _ 221. Anal plumbing 1(44- 9 112. Sound walls 222. Sewer cap/demo. 113. T-bar yid Ie-17-ti a 114. Insulation-Fir. Pool Inspections Date . Insp. 115. Insulation-Wall 240. ExcavatioNsteel 116. Insulation-Ceil. 1. Rough plumbing a1 2& 117. Drywall nailing -47 2. Light shell/bonding 118. Interior lath 243. Underground conduit 119. Exterior lath 244. P-trap 120. Finish grade /7���.�//�p45. Gas line&test 121. Final building ll!-19-I`! - ! 46. Fence,gates&signs 122. Final demo/lot clear 247. Pool heater 248. Final electric Electrical Inspections Date Insp. 249. Anal•lumbin• 150. Power pole 250. Pool cover 151. Sales lot lighting 251. Pool final 152. Under.round conduit 153. Underslab conduit Bernet Inspections I Date Insp. 154. UFER ground 270. Pre-reroof insp. 155. Water ground 271. Roof framing 156. Rough electrical 272. Sheathing nailing 157. Fixtures 273. Final reroof 158. G.F.C.I. 159. E..L bandin• Sign Inspections Date Insp. 160. Service panel80. Setback/overhang 161. Final electric 11-19-I9 281. Footing 282. Conduit/Wain! Mechanical Inspections Date Insp. 283. Disconnect 180. Venting/flue 284. Final sign 181. Furnace/A.C. 182. Rouch HVAC Miscellaneous Insp. Date Insp. _ 183. Are dampers 290. Fire alarm 184. Furnace compartment 291. Underground supply 185. Combustion air 292. Fire sprinklers 186. Smoke detectors 293. Monitor system 187. Metal F.P.rough 294. Hood dry them. 188. Compressor setback 295. Final 189. Commerdal hood 190. Duct shaft Sewers&Offsite Insp. Date I Insp. 191. Final mechanical 11-19-0 it 300. Lateral(main to P/L) 301. SaddleN Block Wall Inspections Date Insp. 302. Cass.*.1 filed 200. Footings 303. Sidewalk 201. SteeVrebar 304. Driveway 202. Grout lift 305. Curb replacement 203. Anal wall 306. Trash bin sot. .W Ye �r '" ..t ,v"..�'svtia7txtn ....:7,27:7,;>,. _____ y�{ ; ,,Th "„^r ' ••. MY¢ '` aY ytr ,�+i`get .:r ?,i? yw ' 14.1.4'.,';lr'E.:;.Q rX � . . IIIl. 4i !_ fi ,: At; k A �' T '' '� e4�e}S :'k\ •,ycis, ct111 tl ,, �y -'4i�Nr.3.4 it „`rill VC 41 I ro.a ,Ccsif.,:ii e�„�m` Certificate of Occupancy y 14 City of Arcadia I ' �k Development Services Department—Building Division .` ro This certificate issued pursuant to the requirements of the = 1 •' California Building Code certifying that at the time of issuance this structure was in 1.0g iy compliance with the various ordinances of the City regulating building construction or use. ,s t t �5 Permit No. TI-18-1704 '� ' g 07x ` Building Address: 376 W. HUNTINGTON DR ARCADIA, CA 91007 i t1 Permit Type: TENANT IMPROVEMENT Effective CBC: 2016 C.B.C. a s' p fi 1.. ! x ' � Occupancy Code: B, A3, SI Zone Code: S_I ,.rf141: St; p . t Final Date: I 1-19-19 il� ��_ Type of Construction: TYPE VB SPRINKLERED , , ' „a Owner: AMERICAN RED CROSS y r M C iF' K nnethFiel uildin fficial , to\ Post in Conspicuous Place , ,� l 1' -a i F*^elax -e=. ten+ x w. r e.,.. 'te t 1 '� 4"y-rr'A.. f �+s. C- t ,� t�sb. -j� �”. "it t keie'1 $ ` t I� C!.�1 , u w�/ kicr; i. .E T IS >�q,�a �'y. \ °`;il �„o� r /! '1' � g � ” . a „ y'r .�i ..7 iV`X' .7, F:.,..\4' ..",P ,war s e,cp - V" ..; �I -..r.k `u,...fil6 ;.:: y1 T*2:a...�i 1 ',,,'ttiaC,f_�' .- , X: "'�' ....}} h.,x' 3. .t ._..a74•1\, :: �r 1�i�'�+� v..:..rn+�r iI^' 'x..... �r `J w+wi��}�� x w. 1 • 4.5n„ -'2�h^ .8 •os• 74 �: -4 *... •te" rr •e[ etl. t'h "5' +'d C�A� �%_: ..73 lid' v5 m44r orsarillOela M0d4ea AIRSOUND-HYDRONIC PROFESSIONALS S Test.and Balance Report PROJECT: American Red Cross Arcadia, CA CONTRACTOR: K & S Air Conditioning ARCHITECT: N/A ENGINEER: N/A REPORT CERTIFICATION NO: 39406 REPORT CERTIFICATION DATE: ooe+Cen tric%'� October 29, 2019 � V63 pNgl od^ C. Michael Conboy REVIEWED AND APPROVED BY: Michael Conboy de�Nxy°c asu, - ICB /TABB Certified Contractor 457 E. Arrow Hwy, Ste. D, Azusa, CA 91702 TEL: 626-915-8117 FAX: 626-915-8112 E-MAIL: associatedairbalance@gmail.com i. I STATE OF CALIFORNIA � £onftactor =? t e I Pursuant to Chapter 9 of Division 3 of the Business and Professions Code j and the Rules and Regulations of the Contractors State License Board, • i the Registrar of Contractors does hereby issue this license to: i MICHAEL CONBOY INC dba ASSOCIATED AIR BALANCE f • to engage in the business or act in the capacity of a contractor I in the following classification(s): '062-AIR AND WATER BALANCING B-GENERAL BUILDING CONTRACTOR Witness my hand and seal this day, May 9,X008 . Issued December 21, 2004 t REPLACEMENT . Steam P Sands Registiar of Contractors This license is the property of the Registrar of Contractors, 851730 is not ttansterrahle•and shall be returned to the Registrar upon demand when suspended,revoked,or Invalidated License Number _ I for any reason.It becomes void it not renewed i nnr-NO 410746 F !i1Ltr .�`• - .�`® ifteaMMSaaltalOARIII Iligil, - F/ on. D INTERNATIONAL TESTING,ADJUSTING AND BALANCING BUREAU CERTIFICATION BOARD THE PROFESSIONAL'S CHOICE" This ceras that AssociatedAir Balance has completed the requirements of certification as a Testing, Adjusting and Balancing Contractor on September 27, 2018 sir 7,?1,rrim. 11" Ak 4 cii.u.-, 4a.k______ NEMIC Labo •thairman 14.2zement ,1. NEMIC Man gement Co-Chairman �/- : 1983 /CB Labor Co-Chairman" 'W a � o s ICB Management Co-Chairma n &vp���'aorco�°`O',4'A 70309451W k °In? as»c_�' DeceM6er31, 2020 Certification No. 1 Expiration Date attonaCerttficat1.o n int etit ® Oci IMIPMINTERNATIONAL TESTING.ADJUSTING AND BALANCING BUREAU CERTIFICATION BOARD THE PROFESSIONAL'S CHOICE" Sheet wietafandAir Conditioning Industry This certifies that ! ichael./4 onbo ifas successfully completed the requirements for Z4(BcB Comm toning Supervisor CX0466110S September 27, 2018 pc,,, c1,3494 t '.v,i ce Certification a f. 4 ' % 1 Labor Co-Chairman s it Y i, 4�newed September27, 2018 ? S, Valid Date C y eti 7----. k� Management Co-Chairman 4ir t ` (December 31, 2020 _.v.‘:ji. , _,ate, ,, _0 L — ,- Expiration Date `"" Administrator of ICB/TABB i Valid during qualified employment i l_• __ weal r Nsl, ANSI Accredited Program PERSONNEL CERTIFICATION ID 80728 INTERNATIONAL ICB/TABB Technician and Supervisor CERTIFICATION BOARD ICES HVAC F1.51 Technician and Supervisor ICC IIVAC FL52 Technician and Supervisor axial/tat- Cert icQt, . •_ . n .79 It" t,elin • �et Sheet !Metal and-Air Conditioning IndCustry This certifies that Kurt J ippert .7f-as successfully completed the requirements for TABB Technician 889689867 May 30, 2018 W ` Vie,' +•'t: -. — CerQn:ation= 't;K ;r!t*AZI. S i Labor l o.�11airmin 26fr . Renewed: !llar, 30, 2018 !•, „t *', Valu!Da iv - g" `L' "'"moi Management Co-Chau'man June 30, 2020 Y7. .TI_ .� !�ii?1!';!1100 :)aL.' Lill/aurin.•y:•�Ininl wu;d„w Inn. - ,- Administralorei TA BB ci, -orb. ANSI ACCREDITED #0728 INTERNATIONAL. TESTING,ADJUSTING ANO BALANCING BUREAU ISO/IEC 17024 CERTIFICATION BOARD THE PROFESSIONALS CHOICE"' Personnel Certification Program 4.4 J , al Cert-v-' ion r et- Sheet lvietat and-Air Conditioning Industry This certifies that Jason A ConboyHas successfully completed the requirements for t ASupervisor T6o395208s (December 18, 2018 t n Stfica:nut+ - �,.....:.? Labor Co Chairman 1Rsn teed (December 18, 2018 t.,:,,: (late :• - Man agement Co Chauia.+n Marcli.31, 2021 »�n d Lista•ion Date ''. "'. Administrator of ft H,r li 1alid dun ne coalthcd cmploi Huns (ilifillACCREDITED #0728 INTERNATIONAL 0/S TADJUSTING AND BALANCING OUREAU ISO/IEC 17024 CERTIFICATION HOARDTHE.PROFESS&O11AVS CHOICE" Personnel Certification Program io Ca 10 aC C2rtZ is ill qfricier- Sheet lvieta! and Air Conditioning industry This certifies that Jason ,,4 GonboyHas successfully completed the requirements for TA7echnician 23139767907 December 7, 2018 j`,,GG"' C rayv...* re .-.,_„�'-. , L.aborCt-Chairman (kenerlwed •Uecemher7, 2018 ` ' Vtnd [este �y .-+,.� Mana8ernent 01-('Imi in on (December 31, 2020 e s M. -•}L.----- 0_,...—,‘-ACI 0_y„.MCI 't---.....:<# P,.pl su•r. Oar.. AWnnnstr aiur c fi.13/7A 11 . try{.')liUrli,l Vualll44 l T.I:;r.).I:•I, 1 h. •w CAANCCREDSITEDI #0728 INTERNATIONAL TESTING,ADJUSTING AND BALANCING BUREAU ISO/IEC 17024 CERTIFICATION BOARD THE PROFESSIONAL'S CROWEY1 Personnel Certification Program aft �►ital Cert fi/ r] .. on tytt,e Yn qincir Sheet Nietai and Air Conditioning Industry This certifies that William . Scrimmaaer 1?fas successfully complete the requirements for 7ABB`3'ec(znician 43,310444827 9l/larch 27, 2019 �.� � I',;1_(K,-1r...,; a f/,�- 1 y Labor Cu Chairrnert (Renewed14arcl 17, 2019i. n 4.,hd 11atr .� ;,-.7^..�:",•- i. h1anagenlent Cu Cham.nan Sr . w #. Marc(31: 2021 _x rt . . .11: C1 iat.oi, I'at,: '• Adm:nutrdtor of ICE!!AB? Valid dill lug.4...111110.i•n.01 .,n.lit THE NATIONAL ENERGY MANAGEMENT INSTITUTE Certificate of Completion Michael Conboy An officer of the Associated Air Balance 457 E Arrow Hwy, Ste D Azusa, CA 91702, has successfully completed the required training fulfilling the requirements of the California Code of Regulations 2016 Title 24, Part 1, sections 10-102 and 10-103, as well as Part 6,Section 120.5 to complete the nonresidential mechanical acceptance tests in accordance with Chapter 13 of the Nonresidential Compliance Manual of the 2016 California Building Energy Efficiency Standards issued Jan. 2017. j‘i; NEMI Director of Training 1/5/2017 Date t rt , t 7 . 1 a.` ' ' ..r.% L l t .. „...,,�, , a . IT `r ) � ACCREDITED CERTIFICATE OF CALIBRATION CUSTOMER: ASSOCIATED AIR BALANCE CALIBRATION DATE: 07/12/2019 PO NUMBER: N/A CALIBRATION DUES 07/12/2020 MT.MANUFACTURER: TSI I ALNOR PROGDURE: NAVAIR 17-20MG-02 INST.DESCRIPTION: BALOMETER CALIBRATION SWIM AIR©14.7 PSI 70°F MODELNUMBER: EBT-731 RE4IVEDCONDMONS: WITHIN MFG.SPECS SERIAL NUMBER: E8T731816027 LEFT CONDITIONS: WITHIN MFG.SPECS RATED UNCERTAINTY: SEE NOTES** AMBIENT CONDITIONS: 760mmHGA 46%RH 69°F UNCERTAINTY GIVEN: *0.796%RD K=2 CERITFICATE FIEN: 490402.2019 NOTES: VEL:t3%RD+t7 FT/MIN•••••PRESS:t 2%RO;t.01°H2O`••'VOL*3%+t7 FT/MIN••••TEMP:30.5°F••••RH%:t3%RD. CALIBRATED WITH DMC ACCESORIES AIRFOIL DM STD GRID DM STD. EBT 731 DM STD. INDICATED ACTUAL INDICATED ACTUAL INDICATED ACTUAL FT/MIN FT/MIN FT/MIN FT/MIN "1420 "H2O 126 127 • 71 70 0.00 0.000 508 511 I 99 100 1.34 1.340 1141 1148 I 216 217 - 5.28 I5.283 1573 1583 582 586 10.11 10.119 2450 2468 1037 1045 1 12.08 12.093 4991 5035 2494 2514 14.96 14.978 UUT IND. DM STD. UUT DM.STD UUT DM STD 1 PIVOT ACTUAL IND. ACTUAL IND. ACTUAL FT/MIN FT/MIN °F °F RH% RH% 2531 2539 69.3 69.6 32.6 33.1 6298 1 6346 98.1 98.3 76.5 77.3 STANDARDS USED: A220:12'WIND TUNNEL 0-8000 FPM I CMC t.203%RD I TRACE#1520423238 I DUE 05232020 A24:HART SCIENTIFIC TEMP.STANDARD I t.024 F 1 TRACE#1520423238 1 DUE 03/072020 1A321:CEC PRESSURE STD.0—600 PSI I t.011%RD I TRACE#1520349429 1519224431 1 DUE 04/02/2020 1 All instruments used in the performance of the shown calibration halve traceability to the National Institute of Standards and Technology MIST). The uncertainty ratio between the calibration standards (DM.STD.) used and the unit under test (UUT) is a minimum of 4:1. unless otherwise noted. Calibration has been performed per the shown procedun: number. in accordance with ISO 10012:2003. ISO 17025:2005. ANSI/NCSL-Z-540.3.and/or MIL-STD-45662A. Test methods:API2530-92&ASME MFC-3M-1989. Dick Munns Company• 1 1 133 Winners Circle• Los Alamitos,CA 90720 Phone(714) 827-1215 Has r,immm°Cmtr:.e, o . •�...4. mrm1 • �i •Ki.annsrmm•w n•¢ma".°.ppia.met todrwmn•m emyawfwmamwo nu nmm mmume*amid:a"„ Date: ( ) .,"11•1YIYl. Calibration Technician iI 11 2Dn •�/.111=�m' I ) , C . Page lofj 1 1 Associated Air Balance 457 E.Arrow Hwy,Ste.F,Azusa,CA 91702 AIR SOUND HYDRONIC PROFESSINALS Tel: 626.915.8117 Fax: 626.915.8112 ABBREVIATIONS • ACT - ACTUAL AK - FREE AREA FACTOR ATC AUTOMATIC TEMPERATURE CONTROL BP • BYPASS(DAMPER VALUE,ETC.) CAV • CONSTANT AIR VOLUME BOX CD - CEILING DIFFUSER CE - CEILING EXHAUST DIFFUSER CFM - CUBIC FEET/MINUTE CF - COEFFICIENT FACTOR CL • CENTER LINE CR - CEILING RETURN INLET DB • DRY BULB DD - DIRECT DRIVE DNL - DATA NOT LISTED EMS - ENERGY MANAGEMENT SYSTEM ENT ENTERING ESP - EXTERNAL STATIC PRESSURE FH - FLOWHOOD(MEASURES CRM DIRECTLY.FPM AND AK FACTORS ARE NOT REQUIRED) FPM - FEET PER MINUTE FPVAV - FAN POWERED VARIABLE AIR VOLUME BOX GPM - GALLONS PER MINUTE HP - HORSEPOWER KW - KILOWATTS L/S • LITER PER SECOND LD - LINEAR DIFFUSER LVG - LEAVING(TEMP,PRESSURE IN INCHES.FPM,CFM) M/S - METER PER SECOND MB • MIXING BOX NA - NOT APPLICABLE/ACCESS NM - NOT MEASURED NVL - NO VALID LOCATION OSA - OUTSIDE AIR PD - PRESSURE DROP RA - RETURN AIR REQ - REQUIRED RPM - REVOLUTIONS PER MINUTE SA SUPPLY AM SFD • SMOKE FIRE DAMPER SP - STATIC PRESSURE SWR - SIDE-WALL RETURN SWS - SIDE-WALL SUPPLY TDH - TOTAL DEAD HEAD TV • THERMALLY PROTECTED VAV • VARIABLE AIR VOLUME BOX W - WATTS WB - WET BULB WG - WATER GAUGE 9P • DIFFERENTIAL PRESSURE AT • DIFFERENTIAL TEMPERATLRE • American Red Cross - Arcadia, Ca Table of Contents System Page Number FCU-1-9DD Fan Test 1 RTU-1 Diffuser Sheet 2 RTU-2 Diffuser Sheet 3 RTU-3 Diffuser Sheet 4 RTU-4 Diffuser Sheet 5 . Page 1 - ` / AIRSOUND-HYDRONIC PROFESSIONALS Direct Drive Fan Test Data Job Name: American Red Cross-Arcadia System: FCU-1-9 UNIT INFORMATION i Unit Number FCU-1-9 Location Data Room Area Served Data Room Manufacturer Daikin Model Number FTXB18AXVJU Serial Number K017636 AIR MEASUREMENTS I DESIGN I ACTUAL Total Fan CFM 560 515 Total Outlet CFM 560 515 Total Traverse CFM N/S N/A Total Return Air CFM N/S N/A Total Outside Air CFM N/S N/A Fan Static Pressure N/S N/A Suction Static Pressure N/S N/A Discharge Static Pressure N/S - -N/A _ Fan Speed Setting N/S High MOTOR MEASUREMENTS I DESIGN I ACTUAL Motor Manufacturer Daikin Motor HP N/S N/S Motor Frame N/S N/S Motor Voltage 208 206 Motor Phase Single Single Motor Amperage 0.24 0.19 Motor Service Factor N/S N/S Motor RPM N/S N/A Design Actual Room Number Size Type Ak FPM CFM FPM CFM Data Room 1 40 x 4 SW 1.00 N/S 560 N/A 515 Total N/S 560 N/A 515 Remarks: • A ',JAW-teas/SA . . Page 2 ` > — AIRSOUND-HYDRONIC PROFESSIONALS Diffuser And Grille Test Data Job Name: American Red Cross-Arcadia Date: 10/28/2019 System: RTU-1 Room I Number Size Type Ak Design Actual %Design FPM I CFM FPM I CFM Value RTU-1 Supply - , Training C 1 24 x 24 CD 1:00 N/S 130 N/S 139 107% Training C 2 24 x 24 CD 1.00 N/S 130 N/S. 128 98% Training C 3 24 x 24 CD 1.00 - N/S. 130 N/S 121 93W Training C 4 24 x 24 CD 1.00 N/S 130 N/S , 133 102% _ Training C 5 24 x 24 CD 1.00 N/S 130 N/S 136 105% Training C 6 24 x 24 CD 1.00 N/S 130 N/S . 119 92% Training C 7 24 x 24 CD 1.00 N/S 130 N/S 143 110% Training C 8 24 x 24 CD 1.00 N/S 130 N/S 139 107% Training C 9 24 x 24 CD 1.00 N/S 130 N/S 128 98% Total NIS 1,170 NIS 1,186 101% RTU-1 Return Training C 1 24 x 24 RG 1.00 N/S N/S N/S 799 Total NIS NIS NIS - 799 - OSA 360 N/S 387 _ 108% Total 360 N/S 387 10B% Remarks: c Cilbe/ .111 � �kiZCl!/IZCL� Page 3 ' AIRSOUND-HYDRONIC PROFESSIONALS Diffuser And Grille Test Data Job Name: American Red Cross-Arcadia Date: 10/28/2019 System: RTU-2 Room Number Size Type Ak Design Actual %Design FPM I CFM FPM I CFM Value •RTU-2 Supply _ Reception 1 24 x 24 CD 1.00 N/S 220 WS 211 96% Reception 2 24x24 CD 1.00 N/S 220 - N/S 204 93% Reception 3 24 x 24 CD 1.00 N/S 220 N/S 239 109% Reception 4 24 x 24 CD 1.00 N/S 220 N/S 228 104% Pantry 5 24 x 24 CD 1.00 N/S 220 N/S 237 108% Pantry 6 24 x 24 CD 1.00 N/S 220 N/S 208 95% Unisex 7 24 x 24 CD 1.00 N/S 35 N/S 33 94% Janitor 8 10 x 10 CD 1.00 N/S 35 N/S 38 109% Total N/S 1,390 N/S 1,398 101% RTU-2 Retum Training C 1 24 x 24 RG 1.00 N/S NIS N/S 1,034 Total NIS N/S NIS 1,034 OSA 335 N/S 364 109% Total 335 N/S 364 109% Remarks: • . . Page 4 AIRSOUND-HYDRONIC PROFESSIONALS Diffuser And Grille Test Data Job Name: American Red Cross-Arcadia Date: 10/28/2019 System: RTU-3 Room Number Size Type pk Design Actual %Design FPM j CFM FPM I CFM Value _ RTU-3 Supply Unisex 1 24 x 24 . CD 1.00 _N/S 35 N/S 36 109% Huddle-04 2 24 x 24 CD 1.00 N/S 250 N/S 240 96% Huddle-03 3 24 x 24 CD 1.00 N/S 250 N/S 236 94% Huddle-02 4 24 x 24 CD 1.00 N/S 250 N/S 227 91% Office Area 01 5 24 x 24 CD 1.00 N/S 220 N/S 214 97% Office Area 01 6 24 x 24 CD 1.00 N/S 220 N/S 206 94% Office Area 01 7 24 x 24 CD 1.00 N/S 220 N/S 207 94% Office Area 01 8 24 x 24 CD 1.00 N/S 220. N/S 212 96% Office Area 01 9 24 x 24 CD 1.00 N/S 220 N/S 206 94% Office Area 01 10 24 x 24 CD 1.00 N/S 220 N/S 203 92% Office Area 01 11 24 x 24 CD 1.00 N/S 220 N/S . 211 96% Office Area 01 12 24 x 24 CD 1.00 N/S ' 22Q N/S 201 91% Office Area 01 13 24 x 24 CD 1.00 N/S 220 N/S 229 104% Office Area 01 14 24 x 24 CD 1.00 N/S 220 NIS 209 95% Total N/S 2,985 NIS 2,839 95% RTU-3 Return Training C 1_ 24 x 24 RG 1.00 N/S N/S N/S 2,234 Total N/S NIS N/S 2,234 _ OSA 575 N/S 605 105% Total 575 N/S 605 105% Remarks: Page 5 A. Sir,eaa< L ice " i AIR,SOUNOd1YDRONIC PROFESSIONALS Diffuser And Grille Test Data Job Name: American Red Crass-Arcadia Date: 10/28/2019 System: RTU-4 Room Number Size Type Ak Design Actual %Design FPM I CFM FPM I CFM I Value RTU-4 Supply . Training AB 1 _ 24 x 24 CD 1.00 N/S N/S N/S 306 Training A/B 2 24 x 24 CD 1.00 N/S N/S N/S 297 Training AB 3 24 x 24 CD 1.00 N/S N/S N/S 259 ' Training AB 4 24 x 24 CD 1.00 N/S N/S N/S 301 Training AB 5 24 x 24 CD 1.00 N/S N/S N/S 257 Training NB. 6 . 24 x 24 CD 1.00 N/S N/S N/S 268 Training NB 7 24 x 24 CD 1.00 NIS N/S N/S 279 Large Conference 8 24 x 24 CD 1.00 NIS N/S N/S 263 Large Conference - 9 24 x 24 CD 1.00 N/S N/S N/S 292 Total N/S N/S NIS 2,522 - RTU-4 Return Training AIB 1 24 x 24 RG 1.00 N/S N/S N/S 1,971 Training AB 2 24 x 24 RG 1.00 ' NIS N/S WS 489 Total N/S N/S N/S 2,460 Remarks: Return 1 has a 16" neck. Return 2 has a 10"neck. There is no OSA. Pankow Request For Information 000021 American Red Cross-Arcadia JOB#: 19-P092-01 RFI ID: 000021 Date Created: September 06, 2019 RFI Status: Returned Authored By: Charles Pankow Builders, Ltd. Steven Cseh TO: KDW SALAS O'BRIEN, LLC Kip Kolodziejski Co-Author RFI# : A schedule or cost impact may occur due to the timeliness or nature of the response to the RFI. If, upon receipt of the response to this RFI, Charles Pankow Builders, Ltd., determines a schedule or cost impact is likely, Charles Pankow Builders, Ltd.,will establish a PCI#to track and submit this impact for contract change order. Subject: ARC ARCADIA Wall Insulation Date Required: September 09,2019 Question: Due to the amount of new work (TV backing, data, power, plumbing etc.) in certain walls, some drywall had to be removed completely up to 8 feet to make patch back cleaner and provide a more quality finish product. Per our building inspection today, any walls where drywall was removed and R11 insulation was exposed,the R11 should be replaced with R15 insulation unless our architect believes leaving R11 in place is acceptable. If R11 is acceptable and approval is given, our inspector is satisfied with leaving R11 in place. Existing insulation in walls that have drywall still intact, does not need to be changed. See attached for photos and locations of walls in question. Pankow believes that leaving R11 intact is the most time effective and cost effective solution. Please confirm if leaving R11 insulation is acceptable. Potential Cost Impact: Potentially Potential Schedule Impact: Potentially Potential Cost Amount: $ Potential Schedule Days: Suggestion: Form_RFI_01 Job#:19-P092-01 Page 1 000021 ,Pankow Answer: Answered by: Kip Kolodziejski Answer Date: September 11, 2019 [THIS EMAIL ORIGINATED OUTSIDE OF THE PANKOW NETWORK] We are unaware of a cost difference between R-15 insulation and any lesser amount. Certainly, placing any existing R-11 insulation that may have fallen during demolition is acceptable. New insulation (insulation that replaced damaged old insulation or uninsulated cavities) should meet current code but if the inspection team is willing to accept R-11, or R-13 for that matter,we take no exception. Operating cost will be slightly higher. Energetically yours, Kip Kolodziejski Architect SALASO'BRIENI expect a difference www.salasobrien.com I kip.kolodziejski@salasobrien.com 206.547.1940 (o)I 206.294.7545 (d) Related Documents: Type: Type Description: Document#: Name: ATTACHMENT 0905-Attachments 000006469 RFI 021 Wall Insulation Distribution List: Charles Pankow Builders,Ltd. Alex Jimenez ' Chades Pankow Builders,Ltd. Bruce Mitchell Charles Pankow Builders,Ltd. Lauren Varela American National Red Cross Alex Fisher Live Design Jonathan Perry Live Design Morgan Backman Form_RFI_01 Job#:19-P092-01 Page 2 000021 Steven Cseh From: Kip Kolodziejski <kip.kolodziejski@salasobrien.com> Sent: Wednesday,September 11,2019 9:28 AM To: Pankow Collaboration Cc: Steven Cseh; Fisher,Alexander; Bruce Mitchell; Lauren Noriega Varela;Alex Jimenez; jonathan@livedesigngroup.com; Morgan Backman Subject RE: 19-P092-01 KK RFI 000021 ARC ARCADIA Wall Insulation ITHIS EMAIL ORIGINATED OUTSIDE OF THE PANKOW NETWORK We are unaware of a cost difference between R-15 insulation and any lesser amount. Certainly, placing any existing R- 11 insulation that may have fallen during demolition is acceptable. New insulation (insulation that replaced damaged old insulation or uninsulated cavities)should meet current code but if the inspection team is willing to accept R-11,or R- 13 for that mattertwe.take no exception! Operating cost will be slightly higher. Energetically yours, Kip Kolodziejski Architect SALAS O'BRIEN I expect a difference I www.salasobrien.com I kip.kolodziejski@salasobrien.com 206.547.1940(o) I 206.294.7545(d) From: Pankow Collaboration<collaboration@pankow.com> Sent: Friday,September 6,2019 1:19 PM To: Kip Kolodziejski<kip.kolodziejski@salasobrien.com> Subject: 19-P092-01KK RFI 000021 ARC ARCADIA Wall Insulation RFI 000021 From Steven Cseh To Kip Kolodziejski CC Steven Cseh,Alex Fisher,Bruce Mitchell,Lauren Varela,Kip Kolodziejski,Alex Jimenez,Jonathan Perry,Morgan Backman Project American Red Cross-Arcadia Subject ARC ARCADIA Wall Insulation Subject: ARC ARCADIA Wall Insulation Date Required: 2019-09-09 Cost Impact: Potentially Cost Amount: Question: Due to the amount of new work(TV backing,data,power,plumbing etc.)in certain walls,some drywall had to be removed completely up to 8 feet to make patch back cleaner and provide a more quality finish product.Per our building inspection today,any walls where drywall was removed and R11 insulation was exposed,the R11 should be replaced with R15 insulation unless our architect believes leaving R11 in place is acceptable.If R11 is acceptable and approval is given,our inspector is satisfied with leaving R11 in place. Existing insulation in walls that have drywall still intact,does not need to be changed.See attached for photos and locations of walls in question. Pankow believes that leaving R11 intact is the most time effective and cost effective solution. Please confirm if leaving R11 insulation is acceptable. Suggestion: Answer: Click here to access this RFI on-line,or simply reply to this email with your comments and any required attachments. 1 IML .:h t -h1 art MEMORANDUM Fire Department DATE: November 20, 2019 TO: BUILDING DEPARTMENT INSPECTOR John Zurick FROM: FIRE DEPARTMENT SUBJECT: FIELD INSPECTION ADDRESS: 376 W. Huntington Drive THE FOLLOWING ITEMS WERE CHECKED FOR CONFORMANCE WITH APPLICABLE FIRE DEPARTMENT REQUIREMENTS: TYPE OF INSPECTIONL DATE / INITIAL FINAL INSPECTION FIRE SPRINKLERS FIRE ALARMS TANKS HOOD 8, DUCT KNOX BOX OCCUPANCY 4-3-2018 Jill Perumean COMMENTS: Emailed Bldg. Dept. 4-5-2018 Rita OF ARC Q��af'�O�4 r MEMORANDUM Fire Department DATE: November 6, 2019 TO: BUILDING DEPARTMENT INSPECTOR Henry Kemich FROM: FIRE DEPARTMENT SUBJECT: FIELD INSPECTION ADDRESS: 376 W. Huntington Drive THE FOLLOWING ITEMS WERE CHECKED FOR CONFORMANCE WITH APPLICABLE FIRE DEPARTMENT REQUIREMENTS: TYPE OF INSPECTION DATE / INITIAL FINAL INSPECTION FIRE SPRINKLERS FIRE ALARMS 11-6-2019 Jill Perumean HOOD & DUCT KNOX BOX OCCUPANCY 11-6-2019 Jill Perumean COMMENTS: Emailed Bldg. Dept. 11-6-2019 Rita