HomeMy WebLinkAboutUntitled City of Arcadia, CA L Permi•tNo: ROOF-19 2033:
Development Services Department :rTh- "t fi ..,7Oir ' , Permrt Type Roof
I
240 West Huntington Drive,Post Office Box 60021 vJ� Si{ -i
Arcadia,CA 91066-6021Li f WsaponReroofRedenti(626)574-5416 - .. - Permrt Status:issued
r e
ARCADIA Issue-pate,:10/07/2019;1 Expiration.
Addr NO. Dir Prefix Street Name Street Suffix Unit City,State,Zip Parcel Number
727 W Longden AVE Arcadia,CA 5383021038
Contacts _. ... . .. . .. . , _
�_ •_ . . �.
Hong ZHANG Owner True Power Solar Contractor
727 LONGDEN AVE,ARCADIA, 201 Clark AVE,Pomona,CA 91767
(714)676-8888 970591
Description:T/0 AND REROOF HOUSE,DETACHED GARAGE Valuation: $ 17,000.00 Tenant
AND GUEST HOUSE WITH CLASS A OWENS CORNING,
OAKRIDGE,DIMENTIONAL COMPOSITION OVER NEW Total Sq Feet: 0.00 Plan Check if Plan it
SHEATHING **SOLAR PERMIT PULLED SEPARATELY"
Fees Amount Payments Amount Paid
Building Issuing Fee $47.01 Total Fees $407.41
Building Permit Fees $354.15 Cash/Receipt 4 REC-02715-19 $407.41
Solid Waste Management Fee $6.25 -
Amount Due: $0.00
Total: $407.41
EXiSTn.-S 54—$11+1•-); Al— /0vsEoi3 1 /0. 9 • ! 1 -Tr —
k�.rsat /o-6 f
9 CALLS FOR INSPECTIONS
Request for inspection by telephone at 626-574-5450. Leave a message
requesting the address,timeframe and what inspection item is needed.
This permit/plan review expires by time limitation and becomes null and
void if the work authorized by the permit is not commenced within 180 days
P 9s from the date of issuance or if the permit is not obtained within 180 days
tol°�� ED from the date of plan submittal.This permit expires and becomes null and
4 void if any work authorized by this permit is suspended or abandoned for 180
consecutive days or if no progressive work has been verified by a City of
Arcadia building inspector for a period of 180 consecutive days.
October 07,2019
Issued By: Date
October 07,2019 Page 1 of 1
,'Jc AR
,. CI'FA L,-I
I ,. 1_ PERMIT/PLAN REVIEW APPLICATION
0y� _ .,
1i, Development Services Department,240 West Huntington Drive,Post Office Box 60021
Arcadia, CA 91066-6021, (626) 574-5416,Fax(626) 447-9173
City of
Arcadia
LICENSED CONTRACTOR'S DECLARATION WORKERS'COMPENSATION DECLARATION
CI hereby affirm under penalty of perjury that I am licensed under provisions of ereby affirm under penalty of perjury one of the following:
i
Chapter 9(commencing with Section 7000,of Division 3 of the Busines and
Professions Code and,! Licens> ' in fu r e anct. 0) 31 I I have and will maintain a certificate of consent to self-insure for workers'
License Class �C YO Li y';��• No. © [Exp. Date I compensation, as provided for by Section 3700 of the Labor Code, for the
l performance of the work for which this permit is issued.
Signature of Contractor
OWNER-BUILDER DEM - RATION ave and will maintain workers'compensation insurance,as required by Section
❑ I hereby affirm under penalty of I;i ury that I am exempt from the Contractors 3700 of the Labor Code,for the performance of the work for which this permit
is issued.My workers'cora enation insurance carrier and policy numbers are:
License Law for the following reason(Section 7031.5,Business and Profession P–
Code.Any city or county which requires a permit to construct,alter,improve, Carrier —�i t"
demolish,or repair any structure,prior to its issuance,also required the applicant policy Number ten�O "(P
for such permit to file a signed statement that he or she is licensed pursuant to the
provisions of the Contractors License Law(Chapter 9(commencing with Section crhis section need not be completed if the permit is for one hundred dollars or less)
7000)of Division 3 of the Business and Professions Code)or that he or she is
exempt there from and the basis for the alleged exemption. Any violation of ❑II certify that in the performance of the work for which this permit is issued,I shall
Section 7031.5 by any applicant for a permit subjects the applicant to a civil not employ any person in any manner so as to become subject to the workers'
penalty of not more than five hundred dollars($500)): compensation Laws of California,and agree that if I should become subject to the
workers'compensation provisions of Sectiopi700 of the Labor Code,I shall
I, as owner of the property, forthwith mp y with those provisions. /
❑ or my employees with wages as their sole
compensation,will do the work,and the structure is not intended or offered for
sale(Section 7044,Business and Professions Code:The Contractors License Date Signature
...-V
Law does not apply to an owner of property who builds or improves thereon,
or who does such work himself or herself or through his or her own -
/
employees,provided that such improvements are not intended or offered for WARNING:.Failure to secure Workers'Compensation coverage is unlawful,
sale.If,however,the building or improvement is sold within one(1)year of and shall subject an employer to criminal penalties and civil fines up to one
completion,the owner-builder will have the burden of proving that he or she hundred thousand dollars($100,000),inaddition:to.the cost of compensation,
did not build or improve for the purpose of sale). damages as provided for in Section 3706 of the Labor Code, interest, and
attorney's fees.
❑I, as owner of the property, am exclusively contracting with licensed
contractors to construct the project(Section 7044,Business and Professions
Code:The Contractors License Law does not apply to an owner of property CONSTRUCTION LENDING AGENCY
who builds or improves thereon,and who contracts for such projects with a I hereby affirm under penalty of perjury that there is a construction lending agency
contractor(s)licensed pursuant to the Contractors License Law). for the performance of the work for which this permit is issued (Section 3097,
Civil Code).
❑ I am exempt under Section 7044,Business and Professions Code,for this reason:
Lender's Name
Date Signature Lender's Address
IMPORTANT: APPLICATION IS HEREBY MADE TO THE BUILDING OFFICIAL FOR A PERMIT SUBJECT TO THE CONDITIONS AND
RESTRICTIONS SET FORTH ON THIS APPLICATION AND THE FOLLOWING:
1. The City's approved plans and permit inspection card must remain on the job site for use by City inspection personnel.
2. Final inspection of the work authorized by this permit is required.A Certificate of Occupancy must be obtained prior to use and occupancy of new buildings
and structures.
3. Per South Coast Air Quality Management District(AQMD)regulations,renovation and remodeling work that results in the removal,stripping,or altering,
of asbestos containing materials requires an asbestos survey and removal prior to disturbing the asbestos.Please contact AQMD at(909) 396-2000 for
further information.
n r
lame d q7)/ r7 rsa Y -- Title —C-7--1
.I certify that I have read this ap, 'cation and state that the above information is correct and that I am the owner or duly authorized agent of the owner.
agree to comply with all ‘ i dinances and State Laws relating to building construction. I hereby authorize representatives of the City of
\ 7dia to enter upon the ab*ntioned
property for inspection purposes. �}ture Date 101 i I( l
l i t'
AFFIDAVIT SELF-CERTIFICATION
FOR COMPLIANCE OF SMOKE ALARMS
AND CARBON MONOXIDE ALARMS
'1'L.� q"` r
Property Address: S `/'-
Permit Number: FBF `\c:1 X1203 3 '—
Brief Job Description: FC--gcscsa= x
Number of smoke alarms installed:
Number of carbon monoxide alarms installed: '.L
When alterations, repairs or additions requiring a permit occur, or sleeping rooms are created,
Smoke alarms shall be installed in each sleeping room, and outside each separate
sleeping area in the immediate vicinity of the bedrooms, and on each additional story of the
dwelling, including basements and habitable attics as required by Section R314 of the 2016
California Residential Code (CRC) and California Health and Safety Code Section 13113.7.
For dwellings or sleeping units containing fuel burning appliances or having attached
garages, carbon monoxide alarms shall be installed outside each separate sleeping
area in the immediate vicinity of the bedrooms, and on each additional story of the
dwelling, including basements as required. by Section R315 of the of the 2016 California
Residential Code (CRC).
Multi-purpose alarms (combination carbon monoxide and smoke alarms) may be used.
All alarms shall comply with requirements for listing and approval by the Office of the State Fire
Marshal. htto://osfm..fire.ca.govilicensingiistinQsiltcenselistinq bml searchcotest.phn
As owner of the above referenced property, I hereby certify that the smoke alarms and carbon
monoxide alarms have been installed in accordance with the manufacturer's instructions and in
compliance with the code sections referenced above.
I declare under penalty of perjury that the foregoing is true and correct, and that this
declaration was executed on (Date) ___4,c,44,9-1/ 9---‘, •1at Arcadia, California.
Owner's Name (printed/typed): yaw- 2-Lu
Signature of Owner: 2<
This affidavit must be returned to the City of Arcadia inspector prior to final inspection
WOKE ALARM AND CARSON MONOXIDE ALARItrOCATIO_Iia
------
Guestlto°mt'liathreu
IStorage
!_,
,_/
11 Family Room _ " 0 ,
Garage
FIRST FLOOR PLAN
.:.= SMOKE ALARM ii t CARSON MONOXIDE ALARM
_: . =�.K gid.,-_—
r# i Mstr
I III' II Bath
Master Bedroom
Dining Room Kitcitett — is
Bad
_ i
1
Nabi ., eit
, , _ closet
Ctotict
i°anufy Room `^ ' ,�.�,' ", '
a, Bedroom Bedroom
--1-
awwmw FLo6R'P<A
5 SM o KE ALARM h s CARBON M{1014®X0 ALARM
i
--' +� lb-14 Permit;NO SOLR 19-2012
+ City of Arcadia, CA , ,
ki
Development Services Department t�^s-' ,-. . —+-" c' Permit,Type Solar
• ', t' 240 West Huntington Drive,Post Office Box 60021 4 ri ; 4 i ii work,C/assiJicoNon Sotar-,Residential
t Arcadia,CA 91066-6021 1-,r . . 1 ti`.�s..,,.{
1 I (626)574-5416 _ -.p , :i1 permit status Issued:
ARCADIA Issueoate 1.0/03/2019_1 Expiration: 03/31/2020
Addr NO. Dir Prefix Street Name Street Suffix Unit City,State,Zip Parcel Number
727 W Longden AVE Arcadia,CA 5383021038
Contacts
Hong ZHANG Owner True Power Solar Contractor
727 LONGDEN AVE,ARCADIA, 201 Clark AVE,Pomona,CA 91767
(714)676-8888 970591
Description:ROOF MOUNT PV SYSTEM, 22 MODULES/1 Valuation: $ 0.00 Tenant
INVERTER
Total Sq Feet: 0.00 Plan Check k Plan k
Fees Amount payments Amount Paid
Building Plan Check Fee Residential $50.00 Total Fees $308.24
Electrical Permit Issuance Fee $47.01 Cash/Receipt if REC-02693-19 $308.24
Fire Plan Check Fee Residential $50.00
. Amount Due: $0.00
Inverters $77.78
Panels $82.45
Solid Waste Management Fee 2 $1.00
Total: $308.24
" �/{G , ����0��, CALLS FOR INSPECTIONS
_., o Request for inspection by telephone at 626-574-5450. Leave a message
�8 E:MC42D/L Afire P#tt/t r requesting the address,timeframe and what inspection item is needed.
KEt "IO
This permit/plan review expires by time limitation and becomes null and
void if the work authorized by the permit is not commenced within 180 days
IIp�� TE from the date of issuance or if the permit is not obtained within 180 days
23 CO V9 LE1 from the date of plan submittal.This permit expires and becomes null and
void if any work authorized by this permit is suspended or abandoned for 180
consecutive days or if no progressive work has been verified by a City of
Arcadia building inspector for a period of 180 consecutive days.
October 03,2019
Issued By: Date
October 03,2019 Page 1 of 1
,F A;
,jFOk 1 i ,
O J
/ 1 PERMIT/PLAN REVIEW APPLICATION
a li . '+
li* Development Services Department, 240 West Huntington Drive,Post Office Box 60021
/.
.r Arcadia, CA 91066-6021, (626) 574-5416,Fax (626) 447-9173
City of
Arcadia
LICENSED CONTRACTOR'S DECLARATION WORKERS'COMPENSATION DECLARATION
I hereby affirm under penalty of perjury that I am licensed under provisions of I hereby affirm under penalty of perjury one of the following:
Chapter 9(commencing with S tion 7000,of Division 3 of the Business and
Professions Co an y lir in ce and ffect. 1:1I have and will maintain a certificate of consent to self-insure for workers'
License Class ii• No. © Exp. Date�213( i a compensation, as provided for by Section 3700 of the Labor Code, for the
Signature of Contractor performance of the work for which this permit is issued.
OWNER-BUILDER DE
�rTION 1L�i I have and will maintain workers'compensation insurance,as required by Section
���"'1 3700 of the Labor Code,for the performance of the work for which this permit
❑ I hereby affirm under penalty o ry that I am exempt from the Contractors is issued.My.wotkers:compensation insurance carrier and policy numbers are:
License Law for the following .,.. S-'.on 7031.5,Business and Professions CC....__�1- 1-
Code.Any city or county whic requires a permit to construct,alter,improve, Carrier
demolish,or repair any structure,prior to its issuance,also required the applicant ^ I
for such permit to file a signed statement that he or she is licensed pursuant to the Policy Number ldetJb,
provisions of the Contractors License Law(Chapter 9(commencing with Section (This section need a completed if the pemu s for one hundred dollars or less)
7000)of Division 3 of the Business and Professions Code)or that he or she is -
exempt there from and the basis for the alleged exemption. Any violation of ❑I certmfy that in the performance of the work for which this permit is issued,I shall
Section 7031.5 by any applicant for a permit subjects the applicant to a civil not employ any person in any manner so as to become subject to the workers'
penalty of not more than five hundred dollars($500)): compensation Laws of California,and agree that if I should become subject to the
workers'compensation provisions of Sectio 0 of the Labor Code,I shall
❑I, as owner of the property, or my employees with wages as their sol:
forthwith om ly with those provisions.
compensation,will do the work,and the structure is not intended or offered forp 3
`I t
sale(Section 7044,Business and Professions Code:The Contractors License la ate I 1 Signature ✓,1///)/
Law does not apply to an owner of property who builds or improves thereon,
or who does such work himself or herself or through his or her own �i
employees,provided that such improvements are not intended or offered for WARNING: Failure to secure Workers'Compensation coverage is unlawful,
sale.If,however,the building or improvement is sold within one(1)year of and shall subject an employer to criminal penalties and civil fines up to one
completion,the owner-builder will have the burden of proving that he or she hundred thousand dollars($100,000),in addition to the cost of compensation,
did not build or improve for the purpose of sale). damages as provided for in Section 3706 of the Labor Code,interest, and
attorney's fees.
❑I, as owner of the property, am exclusively contracting with licensed - -
contractors to construct the project(Section 7044, Business and Professions
Code:The Contractors License Law does not apply to an owner of property CONSTRUCTION LENDING AGENCY
who builds or improves thereon,and who contracts for such projects with a I hereby affirm under penalty of perjury that there is a construction lending agency
contractor(s)licensed pursuant to the Contractors License Law). for the performance of the work for which this permit is issued (Section 3097,
Civil Code).
❑ I am exempt under Section 7044,Business and Professions Code,for this reason:
Lender's Name
Date Signature Lender's Address
IMPORTANT: APPLICATION IS HEREBY MADE TO THE BUILDING OFFICIAL FOR A PERMIT SUBJECT TO THE CONDITIONS AND
RESTRICTIONS SET FORTH ON THIS APPLICATION AND THE FOLLOWING:
1. The City's approved plans and permit inspection card must remain on the job site for use by City inspection personnel.
2. Final inspection of the work authorized by this permit is required.A Certificate of Occupancy must be obtained prior to use and occupancy of new buildings
and structures.
3. Per South Coast Air Quality Management District(AQMD)regulations,renovation and remodeling work that results in the removal,stripping,or altering
of asbestos containing materials requires an asbestos survey and removal prior to disturbing the asbestos.Please contact AQMD at(909)396-2000 for
further information. I'I -1 r"�_��y
Name t5 � ( s/" "'�✓L-- Title —)J C
PRINT NAME
I certify that I have read this ap•lication and state that the above information is correct and that I am the owner or duly authorized agent of the owner.
I agree to comply with all C' ordinances and State Laws relating to building construction. I hereby authorize representatives of the City of
Arcadia to enter upon the ab. .e entioned property for inspection purposes.
Signature Date \01331 6;
Gamma Notes
NOTE: FIRE CODE REFLECTS UPDATES FROM
INTERVENING CODE CYCLE, EFFECTIVE 1 JULY 2018. ROOF PLAN
1111 FIRE SETBACKS AND PATHWAYS COMPLY WITH IRC
R324.6.1, R324.6.2, R324.7.2.6,AND IFC 1204.2.1.1,
1204.2.1.2,AND 1204.2.1.3.
Drawn By:Narek A.
O
n
0
0
Na. Reybim/Sam D t
CONTRACTOR
0
J/B
MSP
True Power Solar
ACD Address:
,., ,.,•,r•• , r,. ',,•^;? ;`•�'+.'r,`...'-i•'
.,,.,
//�� 201 Clark Ave
��jj// a ❑ a Y///A'' INV Pomona,CA 91767
❑ a ❑ s / 7 Phone Number:
(714)676-8888
Lic type:C-46
)11114-PS\1111i1;\
ic#y970591
1�e'1 TRUE POWER
pia —!! S O L A R
rV - Sloe Chane Line klan/uut-Clair
Solar Array 2
17 Canadian Solar 330W
17 P370 Optimizers
Pitch:23 Deg
Orientation: 175 De.
N
0•
,100••m.a Men
W 1AL E
220• oo• Hong Zhang
_ongdenAve 727WLowden Ave,
Arcadia, CA 91007
180°
alms
SCALE OCT 02,2019
I I II ss, AS INDICATED
01 5 10ft
.- PV SYSTEM
PHOTOVOLTAIC ARRAY
(22)Canadian Solar 330W Modules (CS6U-330M)
(1) Solar Edge 6.0KW Inverter(SE6000H-US)
(22) P370 Power Optimizers
0
UNIT INDEX
MSP (E) Main Service Panel
INV (N) Solar Edge Inverter
ACD (N) AC Disconnect
J/B (N) Nema 3R Junction Box
Solar Module
❑ Power Optimizer
EMT type conduit
l///i 36" Setback
:•2?:d 18" Setback 0
FIRM
0
0
ROOF AREA CALCULATIONS
FIRE SPRINKLERS-NO
TOTAL ROOF AREA(SQ.FT.)-3,500
SOLAR AREA(SQ.FT.)-462
%OF COVERED AREA-13.2%
0
Note: All exposed equip/conduit shall be painted to match roof/wall.
1.)
Note: Existing roof tile to be maintained 0 b D
Solar Array I b 0
5 Canadian Solar 330W
5 P370 Optimizers ❑ `,
Pitch:23 Deg b '
Orientation:265 De. b ❑ r'.;
Gate ,
FROM JUNCTION BOX TO ROOF EAVE EMT TYPE CONDUIT WILL RUN OVER
THE ROOF AT 1 1/2"HEIGHT,THEN UNDER THE EAVE TO PV EQUIPMENT
A P D L L U 4650 E.ARROW HWY. STE.A7
STRUCTURAL MONTCLAIR.CA 91763
Structural Calculations for:
FT— _ Hong Zhang Residence
6.60 kW DC Photovoltaic Array Addition
727 W. Longden Ave.
Arcadia, CA 91007
Owner/Developer:
True Power Solar
201 Clark Ave.
Pomona, CA 91767
October 15, 2019
Job#: 19-2090
•QpQFESSI \
76 37 1/4
I Cc Girl 45
'p. 313 120
\`).;?;
I.FOF CAH/
r A'
APO [[U 1 465U E.ARROW HWY. STE.AT
STRUCTURAL MONTCLAIR.CA 91793
`SOLAR RESIDENTIAL ROOF/BUILDING CHECK .1
Check Photovoltaic Array Addition-2016 California Building Code(CBC)
Gravity Design Loads:
Roof Type: Comp shingle over 1/2"sheathing over rafters over 5/8"gypsum board
Live Load: 20.0 psf
Dead Load:
Roofing Material: 2.0 psf
Sheathing: 1.5 psf
Roof Framing Members: 2.5 psf
Drywall: 1.5 psf
Insulation: 1.0 psf
Miscellaneous: 1.5 psf
Solar Array Rack System ` 2.75 psf �
& a. . --Additional Load Applied
Roof Dead Load w/o Solar Array= 10.00 psf Over<50%of Roof Area
Roof Dead Load at Solar Array= 12.75 psf
Total Roof Load w/o Solar Array= 30.0 psf
Total Roof Load at Solar Array= 32.8 psf
Area of Solar Array Addition(for gravity check)= 396 ftt
Total Area of Affected Rafters(for gravity check)= - 1444 ft2
Area of Solar Array Addition(for seismic check)= '396 ft2
Total Area of Affected Roof(for seismic check)= 1444 fta
Check Additional Gravity Loads on Rafters:
Total Load Increase at Affected Rafters= 0.75 psf
%of Total Load Increase= 2.51% < 5.0% OK
Per CBC 3403A.3 Additional Solar Array Weight Is Structurallyy,
"Acceptable
Check Additional Gravity Loads on Lateral Resisting System:
•
Dead Load Increase at Entire Roof= 0.75 psf
%Dead Load Increase on Entire Roof= 7.54% < 10.0% OK
(Per CRC 3403A.4 Additional Solar Array Lateral Load is Structurally
L--: "9Acceptable
r A
Sht: El
APOLLO 4650 E.ARROW HWY.STE.Al Date:
STRUCTURAL MONTCLAIR. CA 91763 0:
I ROOF MOUNTED SOLAR PANELS
E Earthquake Design per ASCE 7-1:1;13.3.1 ''
Design Parameters
Site Class= - ` D .;,,^]Per Table 1613A.3.2 Latitude,deg Longitude,deg
Short Period S.A.,Ss= 2.308 2015 NEHRP Provisions
_.__.____.__ L� 34:1151 118.0550
Site Coefficient,F,= 1.20 Table 1613A.3.3(1)
Sms=F,55= 2.77 EQ 16437
Sps=2/3 Sms= 1.85'xEQ 16439
Importance Factor,IP { 1 00 Section 13.1.3
Height of Equipment,zI 12 00" ft
Height of Roof,h - 12.00'431t
Weight of Panels to each Mount,Wp= 4010sj lbs
aP= 1.00 Table 13.6-1
RP= 2.50 Table 13.6-1
Determine Fp,Seismic Design Force(STRENGTH LEVELI
Fp=(0.4a,Sp5WP)(1+2z/h)/(RP/IP)= 36 lbs EQ 13.3-1
[Not Greater Than:] Fp=1.6SpsWpip= 118 lbs EQ 13.3-2
[Not Less Than:] FP=0.35D5Wpip= 22 lbs EQ13.3-3
Use F,= 36 lbs at each Roof Mount Bracket
Sht: WI
A P O L L 0 �4650 E.ARROW HWY, STE.Al Date: -
MONTCLAIR. CA 91763 #:
STRUCTURAL e: --
• '< ROOF MOUNTED SOLAR PANELS `-
1 _,. Component's anirCladding Wind Load Design per ASCE 7 16;30 4 2 ,h<6o iT j
Design Parameters
r ,
Design Wind Velocity(3s Gust),V=E 110° mph
Wind Exposure= , "C
Mean Panel Height= 12.00,; ift
Total Effective Area of Typical Array=' ` 396'"'aft' •
Panel Area to Each Support= 20.00. ft2
Angle of Panels= `' .'23'",degrees
a=(, 3 ft(aft.Min.)
Determine Wind Force at Each Roof Mount
9h=0.00256 K,Ker Kd V2 I= 13.4 psf Load case 0.6'9„
K,4 '0.85 `Table 30.3-1,Page 317
Ka,= 1.0 Figure 26.8-1,Page 252-253
Kd= 0.85 Table 26.6-1,Page 250
1= 1.0D
Internal Pressure Coeff.=GCPI= 0 +/-(Figure 6-5)
y=0' y=180'
GCP(Zone 1)= 0.45_ :0.85 ... Per Figures 30.4-1 thru 30.4-7
GCP(Zone 2)= 045 ,e-1.60 !Per Figures 30.4-1 thru 30.4-7
GCP(Zone 3)= 0.50' , 2 60 INO PANELS IN ZONE 3
(+)P=qh(GCo-GC,)= 10.0 -21.5 psf,Positive Wind(10 psf min)-Worst Case
Lateral Load at Each Mount= 78 -168 lbs
Compression/Uplift at Each Mount= 184 -396 lbs
l Roof Mount is attached to`roof sheathing&roof nembersw/(1)5/16"x 5',Lag;Belt w/Min 2.S"thread embeel
a
perTRUEPOWER"SOLAR
Allowable Loads for S/16"Diameter Lag Screw per the 2015 NDS "-_,,A
(Table 11.2A) Withdraw)= t. 266,, Ib/in x 2.5"embed x (Cd=1.6)= 1064 lbs
(Table 11K) Shear=t_120 . lb x (Cd=1.6) = 192 lbs
° P4` f mM)-Worst Case
Lateral Load at Each Mount= 78 -168 •lb