Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
Untitled
City of Arcadia, CA L Permi•tNo: ROOF-19 2033: Development Services Department :rTh- "t fi ..,7Oir ' , Permrt Type Roof I 240 West Huntington Drive,Post Office Box 60021 vJ� Si{ -i Arcadia,CA 91066-6021Li f WsaponReroofRedenti(626)574-5416 - .. - Permrt Status:issued r e ARCADIA Issue-pate,:10/07/2019;1 Expiration. Addr NO. Dir Prefix Street Name Street Suffix Unit City,State,Zip Parcel Number 727 W Longden AVE Arcadia,CA 5383021038 Contacts _. ... . .. . .. . , _ �_ •_ . . �. Hong ZHANG Owner True Power Solar Contractor 727 LONGDEN AVE,ARCADIA, 201 Clark AVE,Pomona,CA 91767 (714)676-8888 970591 Description:T/0 AND REROOF HOUSE,DETACHED GARAGE Valuation: $ 17,000.00 Tenant AND GUEST HOUSE WITH CLASS A OWENS CORNING, OAKRIDGE,DIMENTIONAL COMPOSITION OVER NEW Total Sq Feet: 0.00 Plan Check if Plan it SHEATHING **SOLAR PERMIT PULLED SEPARATELY" Fees Amount Payments Amount Paid Building Issuing Fee $47.01 Total Fees $407.41 Building Permit Fees $354.15 Cash/Receipt 4 REC-02715-19 $407.41 Solid Waste Management Fee $6.25 - Amount Due: $0.00 Total: $407.41 EXiSTn.-S 54—$11+1•-); Al— /0vsEoi3 1 /0. 9 • ! 1 -Tr — k�.rsat /o-6 f 9 CALLS FOR INSPECTIONS Request for inspection by telephone at 626-574-5450. Leave a message requesting the address,timeframe and what inspection item is needed. This permit/plan review expires by time limitation and becomes null and void if the work authorized by the permit is not commenced within 180 days P 9s from the date of issuance or if the permit is not obtained within 180 days tol°�� ED from the date of plan submittal.This permit expires and becomes null and 4 void if any work authorized by this permit is suspended or abandoned for 180 consecutive days or if no progressive work has been verified by a City of Arcadia building inspector for a period of 180 consecutive days. October 07,2019 Issued By: Date October 07,2019 Page 1 of 1 ,'Jc AR ,. CI'FA L,-I I ,. 1_ PERMIT/PLAN REVIEW APPLICATION 0y� _ ., 1i, Development Services Department,240 West Huntington Drive,Post Office Box 60021 Arcadia, CA 91066-6021, (626) 574-5416,Fax(626) 447-9173 City of Arcadia LICENSED CONTRACTOR'S DECLARATION WORKERS'COMPENSATION DECLARATION CI hereby affirm under penalty of perjury that I am licensed under provisions of ereby affirm under penalty of perjury one of the following: i Chapter 9(commencing with Section 7000,of Division 3 of the Busines and Professions Code and,! Licens> ' in fu r e anct. 0) 31 I I have and will maintain a certificate of consent to self-insure for workers' License Class �C YO Li y';��• No. © [Exp. Date I compensation, as provided for by Section 3700 of the Labor Code, for the l performance of the work for which this permit is issued. Signature of Contractor OWNER-BUILDER DEM - RATION ave and will maintain workers'compensation insurance,as required by Section ❑ I hereby affirm under penalty of I;i ury that I am exempt from the Contractors 3700 of the Labor Code,for the performance of the work for which this permit is issued.My workers'cora enation insurance carrier and policy numbers are: License Law for the following reason(Section 7031.5,Business and Profession P– Code.Any city or county which requires a permit to construct,alter,improve, Carrier —�i t" demolish,or repair any structure,prior to its issuance,also required the applicant policy Number ten�O "(P for such permit to file a signed statement that he or she is licensed pursuant to the provisions of the Contractors License Law(Chapter 9(commencing with Section crhis section need not be completed if the permit is for one hundred dollars or less) 7000)of Division 3 of the Business and Professions Code)or that he or she is exempt there from and the basis for the alleged exemption. Any violation of ❑II certify that in the performance of the work for which this permit is issued,I shall Section 7031.5 by any applicant for a permit subjects the applicant to a civil not employ any person in any manner so as to become subject to the workers' penalty of not more than five hundred dollars($500)): compensation Laws of California,and agree that if I should become subject to the workers'compensation provisions of Sectiopi700 of the Labor Code,I shall I, as owner of the property, forthwith mp y with those provisions. / ❑ or my employees with wages as their sole compensation,will do the work,and the structure is not intended or offered for sale(Section 7044,Business and Professions Code:The Contractors License Date Signature ...-V Law does not apply to an owner of property who builds or improves thereon, or who does such work himself or herself or through his or her own - / employees,provided that such improvements are not intended or offered for WARNING:.Failure to secure Workers'Compensation coverage is unlawful, sale.If,however,the building or improvement is sold within one(1)year of and shall subject an employer to criminal penalties and civil fines up to one completion,the owner-builder will have the burden of proving that he or she hundred thousand dollars($100,000),inaddition:to.the cost of compensation, did not build or improve for the purpose of sale). damages as provided for in Section 3706 of the Labor Code, interest, and attorney's fees. ❑I, as owner of the property, am exclusively contracting with licensed contractors to construct the project(Section 7044,Business and Professions Code:The Contractors License Law does not apply to an owner of property CONSTRUCTION LENDING AGENCY who builds or improves thereon,and who contracts for such projects with a I hereby affirm under penalty of perjury that there is a construction lending agency contractor(s)licensed pursuant to the Contractors License Law). for the performance of the work for which this permit is issued (Section 3097, Civil Code). ❑ I am exempt under Section 7044,Business and Professions Code,for this reason: Lender's Name Date Signature Lender's Address IMPORTANT: APPLICATION IS HEREBY MADE TO THE BUILDING OFFICIAL FOR A PERMIT SUBJECT TO THE CONDITIONS AND RESTRICTIONS SET FORTH ON THIS APPLICATION AND THE FOLLOWING: 1. The City's approved plans and permit inspection card must remain on the job site for use by City inspection personnel. 2. Final inspection of the work authorized by this permit is required.A Certificate of Occupancy must be obtained prior to use and occupancy of new buildings and structures. 3. Per South Coast Air Quality Management District(AQMD)regulations,renovation and remodeling work that results in the removal,stripping,or altering, of asbestos containing materials requires an asbestos survey and removal prior to disturbing the asbestos.Please contact AQMD at(909) 396-2000 for further information. n r lame d q7)/ r7 rsa Y -- Title —C-7--1 .I certify that I have read this ap, 'cation and state that the above information is correct and that I am the owner or duly authorized agent of the owner. agree to comply with all ‘ i dinances and State Laws relating to building construction. I hereby authorize representatives of the City of \ 7dia to enter upon the ab*ntioned property for inspection purposes. �}ture Date 101 i I( l l i t' AFFIDAVIT SELF-CERTIFICATION FOR COMPLIANCE OF SMOKE ALARMS AND CARBON MONOXIDE ALARMS '1'L.� q"` r Property Address: S `/'- Permit Number: FBF `\c:1 X1203 3 '— Brief Job Description: FC--gcscsa= x Number of smoke alarms installed: Number of carbon monoxide alarms installed: '.L When alterations, repairs or additions requiring a permit occur, or sleeping rooms are created, Smoke alarms shall be installed in each sleeping room, and outside each separate sleeping area in the immediate vicinity of the bedrooms, and on each additional story of the dwelling, including basements and habitable attics as required by Section R314 of the 2016 California Residential Code (CRC) and California Health and Safety Code Section 13113.7. For dwellings or sleeping units containing fuel burning appliances or having attached garages, carbon monoxide alarms shall be installed outside each separate sleeping area in the immediate vicinity of the bedrooms, and on each additional story of the dwelling, including basements as required. by Section R315 of the of the 2016 California Residential Code (CRC). Multi-purpose alarms (combination carbon monoxide and smoke alarms) may be used. All alarms shall comply with requirements for listing and approval by the Office of the State Fire Marshal. htto://osfm..fire.ca.govilicensingiistinQsiltcenselistinq bml searchcotest.phn As owner of the above referenced property, I hereby certify that the smoke alarms and carbon monoxide alarms have been installed in accordance with the manufacturer's instructions and in compliance with the code sections referenced above. I declare under penalty of perjury that the foregoing is true and correct, and that this declaration was executed on (Date) ___4,c,44,9-1/ 9---‘, •1at Arcadia, California. Owner's Name (printed/typed): yaw- 2-Lu Signature of Owner: 2< This affidavit must be returned to the City of Arcadia inspector prior to final inspection WOKE ALARM AND CARSON MONOXIDE ALARItrOCATIO_Iia ------ Guestlto°mt'liathreu IStorage !_, ,_/ 11 Family Room _ " 0 , Garage FIRST FLOOR PLAN .:.= SMOKE ALARM ii t CARSON MONOXIDE ALARM _: . =�.K gid.,-_— r# i Mstr I III' II Bath Master Bedroom Dining Room Kitcitett — is Bad _ i 1 Nabi ., eit , , _ closet Ctotict i°anufy Room `^ ' ,�.�,' ", ' a, Bedroom Bedroom --1- awwmw FLo6R'P<A 5 SM o KE ALARM h s CARBON M{1014®X0 ALARM i --' +� lb-14 Permit;NO SOLR 19-2012 + City of Arcadia, CA , , ki Development Services Department t�^s-' ,-. . —+-" c' Permit,Type Solar • ', t' 240 West Huntington Drive,Post Office Box 60021 4 ri ; 4 i ii work,C/assiJicoNon Sotar-,Residential t Arcadia,CA 91066-6021 1-,r . . 1 ti`.�s..,,.{ 1 I (626)574-5416 _ -.p , :i1 permit status Issued: ARCADIA Issueoate 1.0/03/2019_1 Expiration: 03/31/2020 Addr NO. Dir Prefix Street Name Street Suffix Unit City,State,Zip Parcel Number 727 W Longden AVE Arcadia,CA 5383021038 Contacts Hong ZHANG Owner True Power Solar Contractor 727 LONGDEN AVE,ARCADIA, 201 Clark AVE,Pomona,CA 91767 (714)676-8888 970591 Description:ROOF MOUNT PV SYSTEM, 22 MODULES/1 Valuation: $ 0.00 Tenant INVERTER Total Sq Feet: 0.00 Plan Check k Plan k Fees Amount payments Amount Paid Building Plan Check Fee Residential $50.00 Total Fees $308.24 Electrical Permit Issuance Fee $47.01 Cash/Receipt if REC-02693-19 $308.24 Fire Plan Check Fee Residential $50.00 . Amount Due: $0.00 Inverters $77.78 Panels $82.45 Solid Waste Management Fee 2 $1.00 Total: $308.24 " �/{G , ����0��, CALLS FOR INSPECTIONS _., o Request for inspection by telephone at 626-574-5450. Leave a message �8 E:MC42D/L Afire P#tt/t r requesting the address,timeframe and what inspection item is needed. KEt "IO This permit/plan review expires by time limitation and becomes null and void if the work authorized by the permit is not commenced within 180 days IIp�� TE from the date of issuance or if the permit is not obtained within 180 days 23 CO V9 LE1 from the date of plan submittal.This permit expires and becomes null and void if any work authorized by this permit is suspended or abandoned for 180 consecutive days or if no progressive work has been verified by a City of Arcadia building inspector for a period of 180 consecutive days. October 03,2019 Issued By: Date October 03,2019 Page 1 of 1 ,F A; ,jFOk 1 i , O J / 1 PERMIT/PLAN REVIEW APPLICATION a li . '+ li* Development Services Department, 240 West Huntington Drive,Post Office Box 60021 /. .r Arcadia, CA 91066-6021, (626) 574-5416,Fax (626) 447-9173 City of Arcadia LICENSED CONTRACTOR'S DECLARATION WORKERS'COMPENSATION DECLARATION I hereby affirm under penalty of perjury that I am licensed under provisions of I hereby affirm under penalty of perjury one of the following: Chapter 9(commencing with S tion 7000,of Division 3 of the Business and Professions Co an y lir in ce and ffect. 1:1I have and will maintain a certificate of consent to self-insure for workers' License Class ii• No. © Exp. Date�213( i a compensation, as provided for by Section 3700 of the Labor Code, for the Signature of Contractor performance of the work for which this permit is issued. OWNER-BUILDER DE �rTION 1L�i I have and will maintain workers'compensation insurance,as required by Section ���"'1 3700 of the Labor Code,for the performance of the work for which this permit ❑ I hereby affirm under penalty o ry that I am exempt from the Contractors is issued.My.wotkers:compensation insurance carrier and policy numbers are: License Law for the following .,.. S-'.on 7031.5,Business and Professions CC....__�1- 1- Code.Any city or county whic requires a permit to construct,alter,improve, Carrier demolish,or repair any structure,prior to its issuance,also required the applicant ^ I for such permit to file a signed statement that he or she is licensed pursuant to the Policy Number ldetJb, provisions of the Contractors License Law(Chapter 9(commencing with Section (This section need a completed if the pemu s for one hundred dollars or less) 7000)of Division 3 of the Business and Professions Code)or that he or she is - exempt there from and the basis for the alleged exemption. Any violation of ❑I certmfy that in the performance of the work for which this permit is issued,I shall Section 7031.5 by any applicant for a permit subjects the applicant to a civil not employ any person in any manner so as to become subject to the workers' penalty of not more than five hundred dollars($500)): compensation Laws of California,and agree that if I should become subject to the workers'compensation provisions of Sectio 0 of the Labor Code,I shall ❑I, as owner of the property, or my employees with wages as their sol: forthwith om ly with those provisions. compensation,will do the work,and the structure is not intended or offered forp 3 `I t sale(Section 7044,Business and Professions Code:The Contractors License la ate I 1 Signature ✓,1///)/ Law does not apply to an owner of property who builds or improves thereon, or who does such work himself or herself or through his or her own �i employees,provided that such improvements are not intended or offered for WARNING: Failure to secure Workers'Compensation coverage is unlawful, sale.If,however,the building or improvement is sold within one(1)year of and shall subject an employer to criminal penalties and civil fines up to one completion,the owner-builder will have the burden of proving that he or she hundred thousand dollars($100,000),in addition to the cost of compensation, did not build or improve for the purpose of sale). damages as provided for in Section 3706 of the Labor Code,interest, and attorney's fees. ❑I, as owner of the property, am exclusively contracting with licensed - - contractors to construct the project(Section 7044, Business and Professions Code:The Contractors License Law does not apply to an owner of property CONSTRUCTION LENDING AGENCY who builds or improves thereon,and who contracts for such projects with a I hereby affirm under penalty of perjury that there is a construction lending agency contractor(s)licensed pursuant to the Contractors License Law). for the performance of the work for which this permit is issued (Section 3097, Civil Code). ❑ I am exempt under Section 7044,Business and Professions Code,for this reason: Lender's Name Date Signature Lender's Address IMPORTANT: APPLICATION IS HEREBY MADE TO THE BUILDING OFFICIAL FOR A PERMIT SUBJECT TO THE CONDITIONS AND RESTRICTIONS SET FORTH ON THIS APPLICATION AND THE FOLLOWING: 1. The City's approved plans and permit inspection card must remain on the job site for use by City inspection personnel. 2. Final inspection of the work authorized by this permit is required.A Certificate of Occupancy must be obtained prior to use and occupancy of new buildings and structures. 3. Per South Coast Air Quality Management District(AQMD)regulations,renovation and remodeling work that results in the removal,stripping,or altering of asbestos containing materials requires an asbestos survey and removal prior to disturbing the asbestos.Please contact AQMD at(909)396-2000 for further information. I'I -1 r"�_��y Name t5 � ( s/" "'�✓L-- Title —)J C PRINT NAME I certify that I have read this ap•lication and state that the above information is correct and that I am the owner or duly authorized agent of the owner. I agree to comply with all C' ordinances and State Laws relating to building construction. I hereby authorize representatives of the City of Arcadia to enter upon the ab. .e entioned property for inspection purposes. Signature Date \01331 6; Gamma Notes NOTE: FIRE CODE REFLECTS UPDATES FROM INTERVENING CODE CYCLE, EFFECTIVE 1 JULY 2018. ROOF PLAN 1111 FIRE SETBACKS AND PATHWAYS COMPLY WITH IRC R324.6.1, R324.6.2, R324.7.2.6,AND IFC 1204.2.1.1, 1204.2.1.2,AND 1204.2.1.3. Drawn By:Narek A. O n 0 0 Na. Reybim/Sam D t CONTRACTOR 0 J/B MSP True Power Solar ACD Address: ,., ,.,•,r•• , r,. ',,•^;? ;`•�'+.'r,`...'-i•' .,,., //�� 201 Clark Ave ��jj// a ❑ a Y///A'' INV Pomona,CA 91767 ❑ a ❑ s / 7 Phone Number: (714)676-8888 Lic type:C-46 )11114-PS\1111i1;\ ic#y970591 1�e'1 TRUE POWER pia —!! S O L A R rV - Sloe Chane Line klan/uut-Clair Solar Array 2 17 Canadian Solar 330W 17 P370 Optimizers Pitch:23 Deg Orientation: 175 De. N 0• ,100••m.a Men W 1AL E 220• oo• Hong Zhang _ongdenAve 727WLowden Ave, Arcadia, CA 91007 180° alms SCALE OCT 02,2019 I I II ss, AS INDICATED 01 5 10ft .- PV SYSTEM PHOTOVOLTAIC ARRAY (22)Canadian Solar 330W Modules (CS6U-330M) (1) Solar Edge 6.0KW Inverter(SE6000H-US) (22) P370 Power Optimizers 0 UNIT INDEX MSP (E) Main Service Panel INV (N) Solar Edge Inverter ACD (N) AC Disconnect J/B (N) Nema 3R Junction Box Solar Module ❑ Power Optimizer EMT type conduit l///i 36" Setback :•2?:d 18" Setback 0 FIRM 0 0 ROOF AREA CALCULATIONS FIRE SPRINKLERS-NO TOTAL ROOF AREA(SQ.FT.)-3,500 SOLAR AREA(SQ.FT.)-462 %OF COVERED AREA-13.2% 0 Note: All exposed equip/conduit shall be painted to match roof/wall. 1.) Note: Existing roof tile to be maintained 0 b D Solar Array I b 0 5 Canadian Solar 330W 5 P370 Optimizers ❑ `, Pitch:23 Deg b ' Orientation:265 De. b ❑ r'.; Gate , FROM JUNCTION BOX TO ROOF EAVE EMT TYPE CONDUIT WILL RUN OVER THE ROOF AT 1 1/2"HEIGHT,THEN UNDER THE EAVE TO PV EQUIPMENT A P D L L U 4650 E.ARROW HWY. STE.A7 STRUCTURAL MONTCLAIR.CA 91763 Structural Calculations for: FT— _ Hong Zhang Residence 6.60 kW DC Photovoltaic Array Addition 727 W. Longden Ave. Arcadia, CA 91007 Owner/Developer: True Power Solar 201 Clark Ave. Pomona, CA 91767 October 15, 2019 Job#: 19-2090 •QpQFESSI \ 76 37 1/4 I Cc Girl 45 'p. 313 120 \`).;?; I.FOF CAH/ r A' APO [[U 1 465U E.ARROW HWY. STE.AT STRUCTURAL MONTCLAIR.CA 91793 `SOLAR RESIDENTIAL ROOF/BUILDING CHECK .1 Check Photovoltaic Array Addition-2016 California Building Code(CBC) Gravity Design Loads: Roof Type: Comp shingle over 1/2"sheathing over rafters over 5/8"gypsum board Live Load: 20.0 psf Dead Load: Roofing Material: 2.0 psf Sheathing: 1.5 psf Roof Framing Members: 2.5 psf Drywall: 1.5 psf Insulation: 1.0 psf Miscellaneous: 1.5 psf Solar Array Rack System ` 2.75 psf � & a. . --Additional Load Applied Roof Dead Load w/o Solar Array= 10.00 psf Over<50%of Roof Area Roof Dead Load at Solar Array= 12.75 psf Total Roof Load w/o Solar Array= 30.0 psf Total Roof Load at Solar Array= 32.8 psf Area of Solar Array Addition(for gravity check)= 396 ftt Total Area of Affected Rafters(for gravity check)= - 1444 ft2 Area of Solar Array Addition(for seismic check)= '396 ft2 Total Area of Affected Roof(for seismic check)= 1444 fta Check Additional Gravity Loads on Rafters: Total Load Increase at Affected Rafters= 0.75 psf %of Total Load Increase= 2.51% < 5.0% OK Per CBC 3403A.3 Additional Solar Array Weight Is Structurallyy, "Acceptable Check Additional Gravity Loads on Lateral Resisting System: • Dead Load Increase at Entire Roof= 0.75 psf %Dead Load Increase on Entire Roof= 7.54% < 10.0% OK (Per CRC 3403A.4 Additional Solar Array Lateral Load is Structurally L--: "9Acceptable r A Sht: El APOLLO 4650 E.ARROW HWY.STE.Al Date: STRUCTURAL MONTCLAIR. CA 91763 0: I ROOF MOUNTED SOLAR PANELS E Earthquake Design per ASCE 7-1:1;13.3.1 '' Design Parameters Site Class= - ` D .;,,^]Per Table 1613A.3.2 Latitude,deg Longitude,deg Short Period S.A.,Ss= 2.308 2015 NEHRP Provisions _.__.____.__ L� 34:1151 118.0550 Site Coefficient,F,= 1.20 Table 1613A.3.3(1) Sms=F,55= 2.77 EQ 16437 Sps=2/3 Sms= 1.85'xEQ 16439 Importance Factor,IP { 1 00 Section 13.1.3 Height of Equipment,zI 12 00" ft Height of Roof,h - 12.00'431t Weight of Panels to each Mount,Wp= 4010sj lbs aP= 1.00 Table 13.6-1 RP= 2.50 Table 13.6-1 Determine Fp,Seismic Design Force(STRENGTH LEVELI Fp=(0.4a,Sp5WP)(1+2z/h)/(RP/IP)= 36 lbs EQ 13.3-1 [Not Greater Than:] Fp=1.6SpsWpip= 118 lbs EQ 13.3-2 [Not Less Than:] FP=0.35D5Wpip= 22 lbs EQ13.3-3 Use F,= 36 lbs at each Roof Mount Bracket Sht: WI A P O L L 0 �4650 E.ARROW HWY, STE.Al Date: - MONTCLAIR. CA 91763 #: STRUCTURAL e: -- • '< ROOF MOUNTED SOLAR PANELS `- 1 _,. Component's anirCladding Wind Load Design per ASCE 7 16;30 4 2 ,h<6o iT j Design Parameters r , Design Wind Velocity(3s Gust),V=E 110° mph Wind Exposure= , "C Mean Panel Height= 12.00,; ift Total Effective Area of Typical Array=' ` 396'"'aft' • Panel Area to Each Support= 20.00. ft2 Angle of Panels= `' .'23'",degrees a=(, 3 ft(aft.Min.) Determine Wind Force at Each Roof Mount 9h=0.00256 K,Ker Kd V2 I= 13.4 psf Load case 0.6'9„ K,4 '0.85 `Table 30.3-1,Page 317 Ka,= 1.0 Figure 26.8-1,Page 252-253 Kd= 0.85 Table 26.6-1,Page 250 1= 1.0D Internal Pressure Coeff.=GCPI= 0 +/-(Figure 6-5) y=0' y=180' GCP(Zone 1)= 0.45_ :0.85 ... Per Figures 30.4-1 thru 30.4-7 GCP(Zone 2)= 045 ,e-1.60 !Per Figures 30.4-1 thru 30.4-7 GCP(Zone 3)= 0.50' , 2 60 INO PANELS IN ZONE 3 (+)P=qh(GCo-GC,)= 10.0 -21.5 psf,Positive Wind(10 psf min)-Worst Case Lateral Load at Each Mount= 78 -168 lbs Compression/Uplift at Each Mount= 184 -396 lbs l Roof Mount is attached to`roof sheathing&roof nembersw/(1)5/16"x 5',Lag;Belt w/Min 2.S"thread embeel a perTRUEPOWER"SOLAR Allowable Loads for S/16"Diameter Lag Screw per the 2015 NDS "-_,,A (Table 11.2A) Withdraw)= t. 266,, Ib/in x 2.5"embed x (Cd=1.6)= 1064 lbs (Table 11K) Shear=t_120 . lb x (Cd=1.6) = 192 lbs ° P4` f mM)-Worst Case Lateral Load at Each Mount= 78 -168 •lb