Loading...
HomeMy WebLinkAboutSOLR-19-2362 City of Arcadia, CA \ PermitNO SOLR-19=2362 t' x Development Services Department ���// ''ss(�' }� �-t Per 'it Type:Solar r 240 West Huntington Drive,Post Office Box 60021 ! i c 1 J I� ( - 1`��3VR' WorkClassification:Solar-Residential Over 10"DKV Arcadia,CA 91066-6021 I (626)574-5416 Permit Status:Issued ARCADIA. Issue0ate:12/04/2019,1 Expiration: Addr NO. Dir Prefix Street Name Street Suffix Unit City,State,Zip Parcel Number 322 COLORADO ST Arcadia,CA 91007-2635 5775008010 Contacts MICHAEL WILLIAMS Owner SUNERGY CONSTRUCTION INC` Contractor 322 COLORADO ST 1641 COMMERCE ST,CORONA,CA 92880 (818)415-2820 (951)736-2982 1005730 Description:ROOF MOUNTED SOLAR SYSTEM 38 MODULES/1 Valuation: $ 0.00 Tenant INVERTER Total Sq Feet: 0.00 Plan Check q Plan H e Fees Amount Payments Amount Paid Building Plan Check Fee Residential $50.00 Total Fees $308.24 Electrical Permit Issuance Fee $47.01 Cash/Receipt#REC-03256-19 $308.24 Fire Plan Check Fee Residential $50.00 Inverters $77.78 Amount Due: $0.00 Panels $82.45 Solid Waste Management Fee 2 $1.00 • tCOPLTL1Total: $308.24 l II�Y/44 L CALLS FOR INSPECTIONS Z7�.(q �bca4 �' fj r(E Request for inspection by telephone at 626-574-5450. Leave a message lL� DE7�Grb.G A PF�n��riequesting the address,timeframe and what inspection item is needed. %� ,mss lel This permit/plan review expires by time limitation and becomes null and void if the work authorized by the permit is not commenced within 180 days from the date of issuance or if the permit is not obtained within 180 days from the date of plan submittal.This permit expires and becomes null and void if any work authorized by this permit is suspended or abandoned for 180 consecutive days or if no progressive work has been verified by a City of Arcadia building inspector for a period of 180 consecutive days. 4 . December 04, 2019 Issued By: Date December 04,2019 Page 1 of 1 two,. pi PERMIT/PLAN REVIEW APPLICATION` 0 : .1%rlr`.m ... .+ _J ;Ila' Development Services Department, 240 West Huntington Drive,Post Office Box 60021 Arcadia, CA 91066-6021, (626) 574-5416,Fax (626) 447-9173 City of Arcadia LICENSED CONTRACTOR'S DECLARATION WORKERS'COMPENSATION DECLARATION ❑ I hereby affirm under penalty of perjury that I am licensed under provisions of I hereby affirm under penalty of perjury one of the following: Chapter 9(commencing with Section 7000,of Division 3 of the Business and Professions Costp,andnvmy license is in full//f force and effect. ❑ I have and will maintain a certificate of consent to self-insure for workers' I License Class -el i No.IvaExp. Date 7/-1/A Signature of Contractor compensation, as provided for by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. OWNER-BUILDER DECLARATION 5 0.ve and will maintain workers'compensation insurance,as required by Section ❑ I hereby affirm under penalty of perjury that I am exempt from the Contractors 700 of the Labor Code,for the performance of the work for which this permit License Law for the following reasonMy (Section 7031.5,Business and Professions f is issued".Mylworkers'compen ation insurance carrier and policy numbers are: Code.Any city or county which requires a permit to construct,alter,improve, IrI Carrier T(ct�,A,�"�� « demolish,or repair any structure,prior to its issuance,also required the applicant // Policy Number(�6 3SiNc"-- for such permit to file a signed statement that he or she is licensed pursuant to the (This section need not be completed if the permit is for one hundred dollars or less) provisions of the Contractors License Law(Chapter 9(commencing with Section 7000)of Division 3 of the Business and Professions Code)or that he or she is exempt them from and the basis for the alleged exemption. Any violation of 0 I certify that in the performance of the work for which this permit is issued,I shall Section 7031.5 by any applicant for a permit subjects the applicant to a civil not employ any person in any manner so as to become subject to the workers' penalty of not more than five hundred dollars($500)): compensation Laws of California,and agree that if I should become subject to the workers'compensation provisions of Section 3700 of the Labor Code,I shall I, as owner of the property, forthwith comply with those provisions. ❑ or my employees with wages as their sole compensation,will do the work,and the structure is not intended or offered for Q - A/ _ �,,ql/',,/ sale(Section 7044,Business and Professions Code:The Contractors License Date��lB�/�� Signature/�WI�GL� L'"'"'� Law does not apply to an owner of property who builds or improves thereon, or who does such work himself or herself or through his or her own employees,provided that such improvements are not intended or offered for WARNING: Failure to secure Workers'Compensation coverage is unlawful, sale.If,however,the building or improvement is sold within one(I)year of and shall subject an employer to criminal penalties and civil fines up to one completion,the owner-builder will have the burden of proving that he or she hundred thousand dollars($100,000);in addition to the cost of compensation, did not build or improve for the purpose of sale). damages as provided for in Section 3706 of the Labor Code, interest, and attorney's fees. 0 I, as owner of the property, am exclusively contracting with licensed contractors to construct the project(Section 7044,Business and Professions Code:The Contractors License Law does not apply to an owner of property CONSTRUCTION LENDING AGENCY who builds or improves thereon,and who contracts for such projects with a I hereby affirm under penalty of perjury that there is a construction lending agency contractor(s)licensed pursuant to the Contractors License Law). for the performance of the work for which this permit is issued (Section 3097, Civil Code). ❑ I am exempt under Section 7044,Business and Professions Code,for this reason: Lender's Name Date Signature Lender's Address IMPORTANT:APPLICATION IS HEREBY MADE TO TILE BUILDING OFFICIAL FOR A PERMIT SUBJECT TO TAE CONDITIONS AND RESTRICTIONS SET FORTH ON THIS APPLICATION AND THE FOLLOWING: I. The City's approved plans and permit inspection card must remain on the job site for use by City inspection personnel. 2. Final inspection of the work authorized by this permit is required.A Certificate of Occupancy must be obtained prior to use and occupancy of new buildings and structures. 3. Per South Coast Air Quality Management District(AQMD)regulations,renovation and remodeling work that results in the removal,stripping,or altering of asbestos containing materials requires an asbestos survey and removal prior to disturbing the asbestos.Please contact AQMD at(909)396-2000 for further information. �tJ Name Qa \Tiue P1ecnM,y $iiGI n Lam//\ PRINT NAME certify that I have read this application and state that the above information is correct and that I am the owner or duly authorized agent of the owner. I agree to comply with all City ordinances and State Laws relating to building construction. I hereby authorize representatives of the City of Arcadia to enter upon the above-mentioned property� for inspection purposes. Signaturec4 fi 4 J �, ate is/'/// f _ 322 COLORADO ST A STRING DIAGRAM PROPOSED ARRAY LOCATIONS PROPERTY LLE_ ARRAY NO. AZIMUTH MOUNTMOUNT ROOF RICH 56.59" Q 327 FLUSH MOUNT. 20 I ® 237 FLUSH MOUNT 20 FRONT YARD Q 147 FLUSH MOUNT 20 TO INVERTER 'Iv r CONNECTION (E)DRIVEWAY i BELOW L NOTES isL 1.110]APPROVAL ALL ELECTRICAL EQUIPMENT SHALL BE LABELED,LISTED,OR CERRAED BY ANATIONALLY RECOGNIZED TESTING LABORATORY ACCREDITED BY THE 2 UMTEO STATESOLCIIPATONALYSEn HE4T1 ' ADMINISTRATION. 1 ,ArF 2 MODULES SIWL BE LOCATED NO CLOSER THAN IS'TO A HIP ® II Wln , OR VALLEY HIPOR VALE.RD44ALLBEPLACEDON BOTH SIDES OF AMPOR HEREY.ODU7.2.4. == �I� ■�� i 98 AUXLWiY GROUND TO BE UTILIZED TO COMPLY%MTH u 090<](D).A GEC SIZED TO250.1666.THE GEC WILL BE tail dl 00 CONNECTED DIRECTLY TO THE PREMISE WRING ELECTRODE t21 ■o■e■eane■e■ 4.ROOF SEAVNT IS MI AT THE ROOF PENETRATIONS. "'3 IS �■■■e■■■3 5.VMLL SYSTEM FY DELVING UIIUIYBEFORE ACnVATON OFPV FIb 6.WHEN ABPLHFED BREAKER IS TEMETIODOF UTIUIY ���������` INTERCCNNECRON.BREAKER SHALL NOT READ UNE AND LOAD CEO 89040E). 0 ].ALL ELECTRICAL NOM SHALL BE DESIGNED PER 2017 LOS CCI ANGELES COUNTY ELECTRICAL CODE 2018 CALIFORNIA y', - ELECTRICAL CODE,AMCO CODD 2014 NATIONAL ELECTRICAL OP. n' 1O I B EQUIPMENT LAYOUT NOTES "Ann s = 4 ,,,,,, (E)HOME ABBREVIATIONS LEGEND - ,,,,,,,,, ., I AZ AZIMUTH • JUNCTION BOX m l 13'CAL-FIRIESMOKE (E) EXISTING INVERTER'MTH �� ,6%,,,,,,,,,'" ° I SEE PV3TR OR DIMENSIONS GV. GAS VENT 0 AV. ARVENGVE TO INTEGRATEDDDISCONNECT I CH. CHIMNEY �-I� PV SYSTEM I) lu DISCONNECT FLUSH MOUNTED SOLAR L112J UTILITY OPERATION MODULES AND POWER ( I1 MAIN PANEL BOARD OPTIMIZERS(SEE I ELECTRICAL PANEL INVERTER NO. SPECIFICATION SHEETS REAR YARD PER SINGLE LINE STRING NO. FOR MOUNTING DETAILS) I' (E)AC DISCONNECT w�WREGUIRED FIRE CLEARANCE NO PANELS UTILITY OPERATIONS I, ,,HERE 3'-U'AT ROOF RIDGE AND 18"AT HIPS 'SEE SHEET PV3 FOR + (N)SOLAREDGE TECHNOLOGIES SE10000H-USECINVERTER AND VALLEYS {-moi-) ROOF DIMENSIONS AND -PROPERTY LINE �/ STRUCTURAL ]3.00' -----__J . INFORMATION. SCALE:1"=28-0" Ar MICHAEL WILLIAMS DATE: REVISION: SHEET NAME 1691 COMMERCE STREET. 11.78kWPHOTOVOLTAIC SYSTEM10)8/2019 SITE PLAN CORONA,CA.92880PROJECT ADDRESS: PHONE:(951)7384982 FAX. 322 COLORADO ST CGnStru Gtion Inc. DRAWN BY: SHEET NO, CLSB#1005730 ARCADIA,CA.91007 628-446-2906 GP PV2 ' /Gw„....„, QE\. s _ fi\Iwi\',I 4 la .mn.rwr 00oal15':aw AFFIDAVIT SELF-CERTIFICATION FOR COMPLIANCE OF SMOKE ALARMS AND CARBON MONOXIDEALARMS Property Address: ?) co I n ro. r9 C - Ae C 4 Dt C4— Permitt Number: . &1 a " ) 9 -a3 a v Brief Job Description: Number of smoke alarms installed: La Number of carbon monoxide alarms installed: Cif When alterations, repairs or additions requiring a permit occur, or sleeping rooms are created, Smoke alarms shall be installed in each sleeping room, and outside each separate sleeping area in the immediate vicinity of the bedrooms, and on each additional story of the dwelling, including basements and habitable attics as required by Section R314 of the 2016 California Residential Code (CRC) and California Health and Safety Code Section 13113.7. For dwellings or sleeping units containing fuel burning appliances or having attached garages, carbon monoxide alarms shall be installed outside each separate sleeping area in the immediate vicinity of the bedrooms, and on each additional story of the dwelling, including basements as required by Section R315 of the of the 2016 California Residential Code (CRC). Multi-purpose alarms (combination carbon monoxide and smoke alarms) may be used. All alarms shall comply with requirements for listing and approval by the Office of the State Fire , Marshal. http://osfm.fire.ca.qov/licensinolistings/licenselistinq bml searchcotest.php As owner of the above referenced property, I hereby certify that the smoke alarms and carbon monoxide alarms have been installed in accordance with the manufacturer's instructions and in compliance with the code sections referenced above. I declare under penalty of perjury that the forego'ng is true and correct, and that this declaration was executed on (Date) I3, o •ao - 1 at Arcadia, California. Owner's Name (printed/type . r • / C- wi I I (�'�1S ` , ) Signature of Owner: .-.)--C This affidavit must be returned to the City of Arcadia irispector prior to final inspection Guest Roo 3athrourr lir;.. - --- Storage Family Room •II II L -- - ---- Gating C FIRST FLOOR PLAN C SMOKE ALARM 9 = CARSON MONOXIDE ALARM Mstr Ciati - Pi Master Bedroom Dining Room Kitchen30 — Bath C. Hail , ri Closet .v, Closei — - Closet Family Room (; - — Bedroom Bedroom SECOND FLOOR PLAN a m SMOKE ALARM 0 ='CARBON MONOXIDE ALARW Y r 10/9/2019 Vattete yoursolarplans.com tomtiWOW ENGINEERING SOLUTIONS FOR ALL YOUR SOLAR NEEDS Structural Calculations for SOLAR POWER SYSTEM CONNECTION CHECK AT: 322 Colorado St. Arcadia,CA 91007 Job: Williams,Michael Prepared For: Sunergy Construction Inc. 1641 Commerce Street Corona,CA 92880 (951)782-p372 Design Criteria 1- Code: CALIFORNIA BLDG CODE 2016/ASCE 7-10 2-Wind: 110 MPH,Exposure: C 3 -Wood Species:DF-L No.2(SG= 0.5) Notice:Use restrictions of these calculations. The attached Calculations are valid only when bearing original signature hereon. Contractor/Client to verify existing dimensions/conditions prior to construction &solar racking is installed per manufacturer span requirements. The use of these calculations is solely intended for the above mentioned project. OF ~ O\kG TR�o�Fyc/ c No. C70784 p Exp.0613012021 ` It sr44 OF CALV ° 1-844-PV ELITE]info@yoursolarplans.com 3000 E.Birch Street Suite 201 1 Brea CA 92821 4. r i I t WIND LOADING ANALYSIS - Roof Components and Cladding Per ASCE 7-10 Code for Bldgs.of Any Height with Gable Roof 0 <=45°or Monoslope Roof 0 <=3° Using Part 1 &3:Analytical Procedure(Section 30.4&30.6) Job Name: Williams, Michael Subject: Job Number. Originator I Checker: Input Data: " Wind Speed,V=( 1'10-.;mph (Wind Map, Figure 26.5-1A-C) 3ldg. Classification =I II ;(Table 1-1 Occupancy Category) Exposure Category=I C (Sect. 26.7) B Ridge Height, hr=i 17.10 ;ft. (hr>=he) Eave Height, he=I 8.00 ft. (he a hr) Building Width=i 50.00 ift. (Normal to Building Ridge) Building Length=; 55.00 :ft. (Parallel to Building Ridge) I L Roof Type=' Gable• 1(Gable or Monoslope) k �I Topo. Factor, Kzt=i 1.00 !(Sect.26.8 &Figure 26.8-1) Plan Direct. Factor, Kd= 0.85 i(Table 26.6) Enclosed? (Y/N)I Y ((Sect.28.6-1 &Figure 26.11-1) Hurricane Region?i N Component Name=i Fastener(Purlin,Joist, Decking, or Fastener) hr A Effective Area,Ae= 680 ;ft."2 (Area Tributary to C&C) he Overhangs? (Y/N);__ N _!(if used, overhangs on all sides) L Resulting Parameters and Coefficients: Elevation Roof Angle, 0= 20.00 deg. Mean Roof Ht., h = 15.00 ft. (h =(hr+he)/2,for roof angle>10 deg.) Roof External Pressure Coefficients, GCp: 3Cp Zone 1-3 Pos. = 0.30 (Fig. 30.4-2A,30.4-2B, and 30.4-2C) GCp Zone 1 Neg. = -0.80 (Fig. 30.4-2A, 30.4-2B, and 30.4-2C) GCp Zone 2 Neg. = -1.20 (Fig. 30.4-2A, 30.4-2B, and 30.4-2C) GCp Zone 3 Neg. = -2.00 (Fig. 30.4-2A, 30.4-2B,and 30.4-2C) Positive&Negative Internal Pressure Coefficients, GCpi (Figure 26.11-1): +GCpi Coef. = 0.18 (positive internal pressure) -GCpi Coef. = -0.18 (negative internal pressure) If z<= 15 then: Kz=2.01*(15/zg)^(2/a) , If z> 15 then: Kz=2.01*(z/zg)^(2/a) (Table 30.3-1) a= 9.50 (Table 26.9-1) zg = 900 (Table 26.9-1) Kh = 0.85 (Kh=Kz evaluated at z=h) Velocity Pressure: qz=0.00256*Kz*KzeKd*V"2 (Sect. 30.3.2, Eq. 30.3-1) qh = 22.35 psf qh= 0.00256*Kh*Kzt*Kd*V"2 (qz evaluated at z= h) Design Net External Wind Pressures (Sect.30.4&30.6): For h a 60 ft.: p=qh*((GCp)-(+/-GCpi)) (psf) For h > 60 ft.: p=q*(GCp)-qi*(+/-GCpi) (psf) where:q = qh for roof qi=qh for roof(conservatively assumed per Sect. 30.6) S I , Wind Load Tabulation for Roof Components&Cladding Component z Kh qh p = Net Design Pressures(psf) (ft.) (psf) !one 1,2,3(+ Zone 1 (-) Zone 2 (-) Zone 3(-) Fastener 0 0.85 22.35 10.73 -21.90 -30.84 -48.72 15.00 0.85 22.35 10.73 -21.90 -30.84 -48.72 For z= hr: 17.10 0.85 22.35 10.73 -21.90 -30.84 -48.72 • For z= he: 8.00 0.85 22.35 10.73 -21.90 ---:30.847 -48.72 For z=h: 15.00 0.85 22.35 10.73 -21.90 -30.84 -48.72 Notes: 1. (+)and (-)signs signify wind pressures acting toward&away from respective surfaces. 2. Width of Zone 2(edge), 'a'= 5.00 ft. 3.Width of Zone 3 (comer), 'a'= 5.00 ft. 4. For monoslope roofs with 0<=3 degrees, use Fig. 30.4-2A for'GCp'values with'qh'. 5. For buildings with h > 60' and 0> 10 degrees, use Fig. 30.6-1 for'GCpi'values with'qh'. 6. For all buildings with overhangs, use Fig. 30.4-2B for'GCp'values per Sect. 30.10. 7. If a parapet>= 3' in height is provided around perimeter of roof with 0 <= 10 degrees, Zone 3 shall be treated as Zone 2. 8. Per Code Section 30.2.2, the minimum wind load for C&C shall not be less than 16 psf. 9. Reference: a.ASCE 7-10, "Minimum Design Loads for Buildings and Other Structures". b. "Guide to the Use of the Wind Load Provisions of ASCE 7-10" by: Kishor C. Mehta and James M. Delahay(2004). Roof Components and Cladding: - ii r o o r a o 000ID000G irg.-CI Ira rif 0<= 7 deg. 7 deg. <0 <=27 deg. 27 deg. <0 <=45 deg. Roof Zones for Buildings with h a 60 ft. (for Gable Roofs<=45°and Monoslope Roofs<=3°) U J__`'J___L U 41 -, r a O I I I 1 _J L_ I � ROOF PLAN Roof Zones for Buildings with h > 60 ft. (for Gable Roofs <= 10°and Monoslope Roofs<=3°) • • • • • Gravity Load Data Panel Data Panel:4 MSE3105Q8T Number of Modules:` 38 Weight of PV Module 1r1 40.11{lbs PV Module Dimensions L=, 65.511 in W=�__,39.331 in Roof Data Roof Material:l`Comp_Shingle Roof Dead Load QD=; 101 psf PV System Dead Load Qpy= 3 psf Framing Spacing sroor=L_24j in Linear Dead Load IND=(Do+Qp„)•s,00r= 26 plf Lag Screw Check Lumber:- DF-L No.2 I Uplift Demand Design Wind Pressure p= -30.8 psf(Zone 2) Trib. Depth for Each Rail dp„=L/2= 2.73 ft Trib. Depth for Each Rail bp„=W/2= 1.64 ft Screw Anchor Spacing spy=[6.00 ft(max.) Uplift Force on Each Screw,Portrait UL=(p+Qp„)•dp„t sp„= -456 lbs(Upwards) Uplift Force on Each Screw,Landscape Uw=(p+QP„)`bp,;*sp„= -274 lbs(Upwards) Design Uplift Force Pdpixt=0.6•[Max(U.,Uw)]= -274 lbs(Upwards) Uplift Capacity NDS 2015 Adjustment Factors CD= 1.6 CM= 1 Cr= 1 SG= 0.50 Ce,Cos,C9,Cdi,Ct„are not appicable Speicfic Gravity of Lumber SG= 0.50 NDS Supplement Table 4a Diameter of Lag Screw D=E5/fa:in Withdraw Design fin 1800`SG4R*D"4= 266 ibsfin NDS 201512.1-1 Depth of Embeddment Ip=r'2-.501in Total Nominal Withdrawal Value W=W*l = 665 lbs Withdrawal Design Vaule W=W*C0'CM'Cr= 1064 lbs NDS 2015 Table 11.3.1 Demand-Capacity Ratio P„prnt/W= 0.26 <1 [OKAY] Beam/Top Chord Check Lumber.DF-L No.2 Moment Demand Span: 1 2 3 Orientation j It(ft) pt(lbs) Lenght(ft): 4.67 11.8 11.8 Portrait 1 7.8 -456 2 11.7 -456 Portrait 3 13.2 -456 Linear Dead Load wd= 26 plf 4 17.2 -456 Wind Load, Portrait UL= -456 lbs Portrait 5 18.7 -456 Wind Load, Landscape Uw= -274 lbs 6 22.6 -456 r—� 7 24.1 -456 #of Attachment per Rafter NA=( 8 Portrait wdxz 8 28.1 -456 M(x)=Rt(x— P/(x—f/)— 2000 -- T.:. 1000 = -- p IrI E -1000 0 0 10.0 _ •.o 2f.0 , ' 25.0 30.0 2 -2000 -- 1 1 • -3000 Length x(ft) Ma,Moment Dead 666 lb-ft Dead+Wind 2106 lb-ft Dead+Snow 666 lb-ft Moment Capacity Framing Member Size 12x6 Lumber Grade: DF-L No.2 CM= 1 Cr= 1 Cr 1.15 Cr= 1.3 fb= 900 psi Cb,and CI are not applicable Breadth b= 1.50 in Depth d'= 5.50 in Section Modulus 5, =bd2/6= 7.56 in3 Bending Stress Capacity Fb= CM*Ct*C,*OF*fb= 1346 psi Table 4.3.1 NDS 2015 Co FL;=Cc'Fb Ma*S, ASD Load Design Bending DCR Dead 0.9 1211 psi 1057 psi D 1057 psi 0.87 OKAY Dead+Wind 1.6 2153 psi 3341 psi .6W+.6D 2005 psi 0.93 OKAY Dead+Snow 1.15 1547 psi 1057 psi D+S 1057 psi 0.68 OKAY Deflection Limit E= 1600 ksi I= 20.80 in4 Transient Deflection 0.403 in Transient Deflection Allowed 350 > 180 [OKAY] Total Deflection 0.837 in Total Deflection Allowed 169 > 120 [OKAY] SEISMIC WEIGHT COMPARISON I ANALYSIS -(PER CBC 2016 Part 10 Chapter 4 Section 402 PV System Weight Module Model MSE310SQ8T Panel Weight Wpanoi= 40.1 lbs Number of Panels NPV= 38 Total PV System Weight WPV=Wpanel* NPV= 1523.8 lbs Existing Roof Weight Roof Weight Q= 10.0 psf Building Length Lbmld= 55 ft Building Width Wbuild = 50 ft Roof Area Abulld= 2750 ft` Building Perimeter Pbuild= 210 ft Wall Height ht= 8 ft Wall weight Qvan= 15 psf Interior wall weight Qint= 10 psf Roof Load Wfloor=Abulid*Qo= 27500 lbs Wall Load Nwan=ht/2 *Qwau'Pbuild +Abuna Clint/2= 26350 lbs Total Story Weight Wbulld=Moor+Wwan= .53850 lbs Percentage Weight Increa. WPV/Wbutld= 2.83% <10%OKAY