Loading...
HomeMy WebLinkAboutSOLR-19-2217 �F_ City of Arcadia, CA }° t q Permit'Na SOLR 19 2217 "\-tt Development Services Department D t PermrtType Solar: a 240 West Huntington Drive,Post Office Box 60021 � u Arcadia,CA 91066-6021 - � ,3 `ork Ciassr cation Solar Re_stdentlal Over 10 KV (626)574-5416 "$ �"'�t`"`j ': PermrtStofus:Issued ARCADIA Issu&Date 10/31/2019 1 Expiration: 04/28/2020 Addr NO. Dir Prefix Street Name Street Suffix Unit City,State,Zip Parcel Number 1025 EL SUR AVE Arcadia,CA 91006-4530 8509006016 Contacts v. . . Rv�..•. guoqing wu Owner CLEAN RAYS ENERGY INC Contractor .1025 el sur AVE. - 820 S PALM•AVE 20,ALHAMBRA,CA 91802 (626)360-8299 987339 Description:ROOF MOUNT PV SYSTEM ON MAIN HOUSE, 60 Valuation: $ 0.00 Tenant AMP COMBINER BOX 36 MODULES/MICRO INVERTERS. **NOTE,EXISTING INDEPENDENT PV SYSTEM ON POOL HOUSE Total Sq Feet: 0.00 Plan Check# Plan# AT REAR OF PROPERTY" Fees Amount Payments Amount Paid Building Plan Check Fee Residential $50.00 Total Fees $324.72 Distribution Panel $16.48 Cash/Receipt#REC-02968-19 $324.72 Electrical Permit Issuance Fee $47.01 Amount Due: $0.00 Fire Plan Check Fee Residential $50.00 Inverters $77.78 Panels $82.45 (� compiETE0 Solid Waste Management Fee 2 S1.00 (� I Total: $324.72 f-tS/ /p CALLS FOR INSPECTIONS � I " r Request for inspection by telephone at 626-574-5450. Leave a message requesting the address,timeframe and what inspection item is needed. ,V This permit/plan review expires by time limitation and becomes null and void if the work authorized by the permit is not commenced within 180 days from the date of issuance or if the permit is not obtained within 180 days from the date of plan submittal.This permit expires and becomes null and void if any work authorized by this permit is suspended or abandoned for 180 consecutive days or if no progressive work has been verified by a City of Arcadia building inspector for a period of 180 consecutive days. • October 31,2019 Issued By: Date October 31,2019 Page 1 of 1 1,.1004y• 9 k PERMIT/PLAN REVIEW APPLICATION E Development Services Department,240 West Huntington Drive,Post Office Box 60021 ry/a Arcadia, CA 91066-6021, (626) 574-5416,Fax(626) 447-9173 City of Arcadia ICENSED CONTRACTOR'S DECLARATION WORKERS'COMPENSATION DECLARATION hereby affirm under penaltyof perjury that I am licensed under provisions of I hereby affirm under penalty of perjury one of the following: hapter 9(commencing with Section 7000,of Division 3 of the Business and ti ofessions Co and my license is in fu i+, e e ect. ❑ I have and will maintain a certificate of consent to self-insure for workers' �, se Class , _ i - Exp. Date V- compensation, as provided for by Section 3700 of the Labor Code, for the /� performance of the work for which this permit is issued. r azure of Contracto % i OWNER-BUILD R DECLARATION I have and will maintain workers'compensation insurance,as required by Section ❑ I hereby affirm under penalty of perjury that I am exempt from the Contractors 3.700 of the Labor Code,for e performance of the work for which this permit cy numbers are: License Law for the following reason(Section 7031.5,Business and Professions is issued.My workers'c. Tin msur Code.Any city or county which requires a permit to construct,alter,improve, . Carrier /prr a pd-peli demolish,or repair any structure,prior to its issuance,also required the applicant Policy Number for such permit to file a signed statement that he or she is licensed pursuant to the (This section need not be completed if the permit is for one hundred dollars or less) provisions of the Contractors License Law(Chapter 9(commencing with Section 7000)of Division 3 of the Business and Professions Code)or that he or she is _t I certify that in the performance of the work for which this permit is issued,I shall exempt there from and the basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a permit subjects the applicant to a civil not employ any person in any manner so as to become subject to the workers' penalty of not more than five hundred dollars($500)): compensation Laws of California,and agree that if I should become subject to the workers'compensation provisions of Section 3700 of the Labor Code,I shall ❑I, as owner of the roe f.nhwith comply with those provisions. property,rty, or my employees with wages as their sole compensation,will do the work,and the structure is not intended or offered f. /a— J/—/9 sale(Section 7044,Business and Professions Code:The Contractors License Date Signature Law does not apply to an owner of property who builds or improves thereon, , or who does such work himself or herself or through his or her own employees,provided that such improvements am not intended or offered for WARNING: Failure to secure Workers'Compensation coverage is unlawful, sale.If,however,the building or improvement is sold within one(1)year of and shall subject an employer to criminal penalties and civil finesup to one completion,the owner-builder will have the burden of proving that he or she hundred thousand dollars($100,000);in addition to the cost of compensation, did not build or improve for the purpose of sale). damages-as provided for in Section 3706 of the Labor Code, interest, and attorney's fees. 0 I, as owner of the property, am exclusively contracting with licensed contractors to construct the project(Section 7044,Business and Professions Code:The Contractors License Law does not apply to an owner of property CONSTRUCTION LENDING AGENCY who builds or improves thereon,and who contracts for such projects with a I hereby affirm under penalty of perjury that there is a construction lending agency contractor(s)licensed pursuant to the Contractors License Law). for the performance of the work for which this permit is issued (Section 3097, Civil Code). ❑ I am exempt under Section 7044,Business and Professions Code,for this reason: Lender's Name Date _Signature Lender's Address IMPORTANT:APPLICATION IS HEREBY MADE TO THE BUILDING OFFICIAL FOR A PERMIT SUBJECT TO THE CONDITIONS AND RESTRICTIONS SET FORTH ON THIS APPLICATION AND THE FOLLOWING: 1. The City's approved plans and permit inspection card must remain on the job site for use by City inspection personnel. 2. Final inspection of the work authorized by this permit is required.A Certificate of Occupancy must be obtained prior to use and occupancy of new buildings and structures. 3. Per South Coast Air Quality Management District(AQMD)regulations,renovation and remodeling work that results in the removal,stripping,or altering of asbestos containing materials requires an asbestos survey and removal prior to disturbing the asbestos.Please contact AQMD at(909) 396-2000 for further information. ' eLsT timSe ✓aH Title PRINT NAME � ertify that I have read this application and state that the above information is correct and that I am the owner or duly authorized agent of the owner. fagree t comply with all City ordinances and State Laws relating to building construction. I hereby authorize representatives of the City of I A>`cadia to enter upon the above-mention d property for inspection purposes. !` - /0/ 10- g1 - 19 i rtature .a .L—!L _-- Date • ‘ 01- 5 E,\ 5u 4. - 0,04Q- _ . 7. ° /\ ot-4 Imp BOE El mni AC COMBINER �= _AI WITH MONITORING DEVICE • AC DISCONNECT ALSO RAPID SHUTDOWN MAIN SERVICE PANEL CAUTION: POWER TO THIS BUILDING IS SUPPLIED FROM • THE FOLLOWING SOURCES WITH DISCONNECTS LOCATED AS SHOWN LG345N1C-V5 I LG350N1C-V5 ° d . D LG N ON2 Mechanical Properties Electrical Properties(STC') ' 'Cells 6x10 ModuleType 345W _ 350W Cell Vendor • LG Maximum Power Pmax(W) 345 350 CefType Monocrystalline/N-typeI,MPP Voltage Vmpp(V) 349 35.3 Cell Dimensions 161.7 x1617mm MPP Current lmpp(A) 9.89 9.92 '•of Busbar 12(Multi Wire Busher) .'Open CirtuitVoltageVocM 412 413 Dimensions(Lx Wx H) 1686 x1016 x 40 mm Short Circuit Cdrmlt Ise(A) 10.57 1061 'Font Load(test) 5400 Pa Module Effidmry(%) 20.1 204 Rear Load(test) 4000 Pa 'Operating Temperature(°C) -40-.90 'Weight 17.1 kg 'Maximum System Voltage(V) 1000 CoraecforType Genuine MC4,IP69 Smits Maximum Ses Fuse Rating(A) 20 (Male:PV-K.ST4)(Female PV-1(B1-4) paw Tolerance(%) 0-t3 Junction Box IP68 with 3 bypass diodes Length of Cables rax 1000 mm The SIC(Standard Test Condition):Irradiance 1000 Wm',Module Temperature 25°C,AM 15 The nameplate power output is measured and determined by LG Electronics at its sole and absolute discretion. •Front cover High transmission tempered glass Frame Anodised aluminum with protective matt black mating Electrical Properties(NMOT') Module Type 345W 350W Certifications and Warranty Maximum Power Pmax(NO 258 261 ISO 9001,15014001,15050001 M PP Voltage Vmpp M 327 3304 IEC fi1215-1/-1-1/2:2016. • 'MPP Current lmpp(A) 7.89 7.91 IEC 61730-1/-2:2016,UL1703 certifications OHSAS 1001,PV CYCLE Open Circuit Voltage Voc(V) 38.7 38.8 IEC 617012013 Severity 6 Short Circuit Current Ise(A) 8.50 8.53 . (Salt Mist Corrosion Test) a NMOT(Nominal Module Operating Temperature):Irradiance 800 W/m',ambient temperature 20°C, ' IEC 62716:2013(Ammonia Test) wind speed 1 m/s,Spectrum AM 1.5. Module Fre Rating Class C(UL 790,ULC/ORD C 1703) .Product Warranty 25 Years Dimensions(mm) r..... OutputWarranty of Pmax (Measurement idm enm f 3%) Linear Warranty' 11)1st year 982)After tstyear.033%annual degradation,3)9008%for 25 years. '� ua %. Temperature Characteristic I j n m 'NMOT 423°C Uo ,.nA 'f" Pmax -0.36%/°C 'Voc -0.27%PC MERIN 'Ise 003%/°C Frame CrosSacmun Current-Voltage characteristics at various irradiance levels n'°a.^..I vatam mm.s•,,....w ..w�l ." 1000W/m' 'nor ° «m e eaoW/.5 8m' .....Iw v 600W/m' \ill v..«e. I '1 6 uwuarm PJ \ L.� 400WOW V 4 (- .l 200W1m' 0 1) 20 30 \20 SO Voltage(V) cep Current-Voltage characteristics at various cell temperatures i_P .1 °) a1 If � rue $I i y 9 a I� ..... . . . . .. ... ......_..._...._ I 1 Inc g W - _ _ _ II nto _ _� .__._ ...... Ver imam • to _ I 40 ._ ._- - .. ! 1 20 .. ..- ... ..-. 025 - ]]''�� d0 .l.2.50 2s 50 90 8 % ,i Hi,d _ Temperature(°C) s+i �, LO Electronics Australia Pty Ltd LG Electmnia Inc. Product specifications are subject to change �7� •0 /�I LG Solar Business Group Solar Business Division without prior01 notice. ` LDate07/2019 2Wr Business Drive,ouEastern Creek,NSW 2766 inWestar Tower,116 'O—_s11: Ph:(02)88054038 128,Yeoui-daero,Ymngdeurgpo-gu. ❑1°ip— LifesGood E-Mail:solarsales@igemmau 5em1,07336,Korea Copyright 02019 LG Electronics. •L Web:lgenergycom.au www.lgcom/giobaVbuvness All rights reserved. • .Data Sheet Enphase Microinverters Region:APAC Enphase The high-powered smart grid-ready 0 7 and Q / + Enphase IQ 7 Micro" and Enphase IQ 7+Micro"' achieve the highest system efficiency. Microinverters Part of the Enphase IQ System,the IQ 7 and IQ 7+ Micro integrate seamlessly with the Enphase Envoy-S",and the Enphase EnlightenTM monitoring and analysis software. The IQ 7 and IQ 7+ Micro extend the reliability standards set forth by previous generations and undergo over a million hours of power-on testing, enabling Enphase to provide an industry-leading warranty. Easy to Install . •-- • Lightweight and simple fa,-;:�r- • Faster installation with improved,lighter two-wire cabling 11._ Productive and Reliable I.�a • Optimized for high powered 60-cell and 72-cell*modules ef • More than a million hours of testing .V • Class II double-insulated enclosure w _ENPHASE I°' _ Smart Grid Ready • Complies with advanced grid support,voltage and frequency III] L•••Y '� ride-through requirements a % a • Remotely updates to respond to changing grid requirements • Configurable for varying grid profiles *The IQ 7+Micro is required to support 72-cell modules ENPHASE. To learn more about Enphase offerings,visit enphase.com/au a . 1 Enphase IQ 7 and IQ 7+ Microinverters INPUT DATA(DC) IQ7-60-2-INT IQ7PLUS-72-2-INT `.Commonly used,module pairings' 235W-350W+ _ 235W-440W+ Module compatibility 60-cell PV modules only 60-cell and 72-cell PV modules Maximuminput DC voltage - .� �� � 48V _ - 60V i Peak power tracking voltage 27 V-37 V 27 V-45V Operating range 16V-48V �• 16V-60V • l Min/Max start voltage 22 V/48 V 22 V/60 V Mex DC short circuit current(moduleisc). 15 A - 15 A Overvoltage class DC port II II DC.por{backfeed under single PV array configuration AC side protection requires max 20A per branch circuit OUTPUT DATA(AC) IQ 7 Microinverter I0 7+Microinverter ,Peak output power 250 VA 295 VA Maximum continuous output power 240 VA 290 VA Nominal(L-N)voltage/range' _ -- --- 230 V/184-276 V -- 230 V/194-276 V - - --� Maximum continuous output current 1.04 A 1.26 A Nominarfrequency - ISO Hz•` '• _ SO Hz Extended frequency range 45-55 Hz 45-55 Hz Maximum units per 20 A(L-N)branch circuit 16(230 VAC) Overvoltage class AC port III III AC poll ____ed current OA A. Power factor setting 1.0 1.0 Power factor(adjustable) 0.7leading...0.7 lagging. 0.7leading...0.7 lagging EFFICIENCY @230 V @230 V EN 50530(EU)weighted efficiency 96.5% - 96.5% • ! MECHANICAL DATA I Ambient temperature range -40°C to+65°C Relative humidity range 4%to 100%(condensing) Connectortype MC4(orAmphenol H4UTXwithaddit1onal 0;DCC-5 adapter) Dimensions(WxHxD) 212 mm x 175 mm x 30.2 mm(without bracket) Weight _.. -- - ------ 1.08 kg -I Cooling Natural convection-No fans Approved for wet locations Yes i Pollution degree PD3 lassII d Enclosure Class II double-insulated Environmental category/UV exposure rating Outdoor-IP67 FEATURES Communication Power Line Communication(PLC) ' Monitoring Enlighten-Manager and MyEnlighten monitoring options Compatible with Enphase IQ Envoy Compliance(pending) -• 2, 19M IEC/EN 61000-6-3= IE IEC/EN/EN 62019 1 IEC/EN-62109-2 1.No enforced DC/AC ratio.See the compatibility calculator at httos•//enphase cam/en-us/su000rt/module-compatibility. 2.Nominal voltage range can be extended beyond nominal if required by the utility. To learn more about Enphase offerings,visit enphase.com/au ©2018 Enphase Energy.All rights reserved.All trademarks or brands used are the property of Enphase Energy,Inc. EN P H A S E. 2018-01-23 `� 5 ' SWH Racking System Data Sheet Version 1210.v2 c( SOLAR WAREHOUSE SWH Solar Mount Tile Strut MFG-PN: MR-SW-TT-6B, MR-SW-TT-6S, MR-SW-TT-4S, MR-SW-TT-45B Base and Channel Nut Materials: ___ •___-_ __ __ _� __ ___—_ ______._�__,_-_____ _ • 6005-T5 extruded aluminum alloy • Clear or black anodized • J.: laFasteners and Flashing Materials: L • 304 stainless steel iI tit. Il L. • Tigten threaded rod onto channel nut a -p- I to 14 ft-lbs torque • .4 _ *Product not recommended for clay or slat tiles. ;/ t ••5/16"x 3.5"Stainless Steel lag bolt included. f T % �t \,,t CONFORMS TO UL SUB 2703 rr: •� IyL [J� , (_� - G,,L I us vr" _ik, Intertek SW-TT-6 SW-TT-6B SW-TT-4S SW-TT-4SB 4009330 6" ROD 6" ROD 4" ROD 4" ROD Lag pull-out(withdrawal)capacities abs)in typical roof lumber(ASD) Sources: American Wood Council, NDS 2005, Table 11.2a, 11.3.2A. sA,"lag screw*specifications Notes: ' Specific gravity per inch thread depth (1)Thread must be embedded in the side grain of a rafter or other structural member integral with Douglas Fir,Larch 0.50 266 building structure. (2)Lag bolts must be located in the middle third of' Douglas Fir,South .46 235 '1 il the structural member. Engelmann Spruce,Lodgepole Pinel .46 235 1 (3)These values are not valid for wet service. ' Hem,Fir,Redwood(close grain) .43 212 (4)This table does not include shear capacities. If Hem,Fir(North) .46 235 necessary,contact a local engineer to specifiy lag bolt size with regard to shear forces. Southern Pine .55 307 (5)Install lag bolts with head and washer flush to' Spruce,Pine,Fir .42 205 f surface(no gap).Do not over-torque. Spruce,Pine,Fir2 .50 266 (6)Withdrawal design values for lag screw connec- Thread - tions shall be multiplied by applicable adjustment depth factors if necessary. See Table 10.3.1 in the , IMSR 1650 f &higher - American Wood Council NDS for Wood Construo, 2E of 2 million psi and higher grades of MSR and MEL L tion. *Use flat washers with lag screws. Z Axial Load Capacity Note: Loads are given for tile strut only. Check load limits for lag screw X y or other attachment methods. Average Average Average Base Assembled Part Ultimate Load Ultimate Load Ultimate Load Dimension Weight lbs (N) X± lbs (N)Y± lbs (N)Z± W x L x H SWTTO8 6" rod 154(685) 137 (609) 7688(34198) 1.75" x 8" x 1" 0.936 lbs SWTTO8 4" rod 359(1597) 370(1646) 8569 (38117) 1.75" x 8" x 1" 0.888 lbs SWTT08S 6" rod 150(667) 139 (618) 4215 (18749) 1.75" x 8" x 0.75" 0.870 lbs SWTTO8S 4" rod 313 (1392) 313 (1392) 4279(19034) 1.75" x 8" x 0.75" 0.822 lbs *Independent Laboratory Tested ' 9628 Valley Blvd. Rosemead, CA 91770 I Phone 626-579-3288 I info©esolarwarehouse.com . • eie SWH Racking System Data SheetVersion12.10v2 SOLARWAREHOUSE SWH Solar Mount Rail MFG-PN: MR-SW-SR-10.5, MR-SW-SR-12, MR-SW-SR-14, MR-SW-SR-14B, MR-SW-SR-17 SLOT FOR 1/4"T-BOLT OR HEX BOLT 7 7 • Rail material: 6063-T5 extruded aluminum alloy SLOT FOR • Finish: Clear or black anodized f TBT OR HEX BOLT 2.25" CONFORMS TO UL STD 2703 OR SLOT FOR f—0 3/8" BO GUS OR HEXEXBOLT - ►X Iso" Int rtek 4009330 Properties Units Solar Mount Beam Height in 2.250 Approximate Weight plf 0.700 Total Cross Sectional Area in2 0.588 Area Moment of Inertia X-Axis in 0.2991 Area Moment of Inertia Y-Axis in° 0.038' Tensile Strength MPa 190.2491 Yield Stregth MPa 165.7321 Elongation (G.L.=25mm) % 17.2 Hardness (HR15T) 71 'updated 6/12/2012 Typical Composition Material %Si % Fe %Cu, % Mn % Mg %Zn % Ni % Cr %Pb %Sn %Ti %Al 6063 0.3972 0.2679 0.0469 0.0666 0.4936 0.0436 0.0056 0.0205 0.0010 0.0044 0.0188 98.6 Solar Warehouse"is a registered trademark and DBA of Calmonte Corporation. •9628 Valley Blvd. Rosemead, CA 91770 I Phone 626-579-3288 I info@esolarwarehouse.com 'j tl SWH Racking System Data Sheet Version12.10.v2 �i SOLAR WAREHOUSE SWH Grounding Mid Clamp Part No.EA-SW-GM-25B, EA-SW-GM-25K • Conforms to UL STD 467 (10 AWG) EA-SW-GM-25E • Mid clamp material:304 or 316 stainless steel • Bolt&nut material: 304 and/or 316 stainless steel • Assembled mid clamp weight: 0.078 lbs (with hardware) 03,&.1-T ' • i • Assemble mid clamp with one 1/4" Grounding T-bolt and one 1/4"-20 ASTM F594 serrated flange nut . Use anti-seize and tighten to 8 ft-lbs of torque MODEL N T-BOLT LENGTH MODULE HEIGHT _EA-SW-GM-25B 50MM <=32mm EA-SW-GM-25K 60MM 33-42mm EA-SW-GM-25E 70MM 43-50 mm / . '171 ,;,, • f° ▪ •-_- SWH stainless steel UL2703 FRONT SIDE ` , c® t.. y , \ mid clamp penetrates LISTED / _ solar module frame 1 ^ anodization to create i i . / \ 1 grounding path. + �-- GIS Intertek r±"44. , ��. /f4009330 !_ I I ,I SWH stainless steel R i -v i14 grounding T-bolt penetrates solar rail 1 ; I [ _)1 xl. anodization to create - grounding path. .. -__ -_ , GROUNDING I I ' I - , BOLT/LUG , I 11 '--� .25"DISTANCE ,�_ • — i''-L = BETWEENMI ^' „o MODULES NM - �t MODULE MODULE Y �x RAIL ,., _ _ __..� ,. _ INCORRECT CORRECT Dimensions specified in inches unless noted 9628 Valley Blvd. Rosemead,`CA 91770 I Phone 626-579-3288 I info@esolarwarehouse.com • mo 0 Fi. • OµVtil t Ir .%.• ,c. so- -' AFFIDAVIT SELF-CERTIFICATION FOR COMPLIANCE OF SMOKE ALARMS AND CARBON MONOXIDE ALARMS • Property Address: 10 2 5 �-1 stir A - Permit Number 6 0 L '\ ( ? 2 2 Brief Job Description: SC i 4,n P-oo-� �1) Number of smoke alarms installed: * 6. , ; Number of carbon monoxide alarms named: --2---", When alterations, repairs or additions requiring a permit occur, or sleeping rooms are created, _ Smoke alarms shall be installed in each sleeping room, and outside each separate sleeping area in the immediate vicinity of the bedrooms, and on each additional story of the dwelling, including basements and habitable attics as required by Section R314 of the 2016 California Residential Code (CRC) and California Health and Safety Code Section 13113.7. For dwellings or sleeping units containing fuel burning appliances or having attached garages, carbon monoxide alarms shall be installed outside each separate sleeping area in the immediate vicinity of the bedrooms, and on each additional story of the dwelling, including basements as required by Section R315 of the of the 2016 California Residential Code (CRC). Multi-purpose alarms (combination carbon monoxide and smoke alarms) may be used. All alarms shall comply with requirements for listing and approval by the Office of the State Fire Marshal. http://osfm.fire.ca.qov/licensinglistings/libenselistino bml searchcotest.php As owner of the above referenced property, I hereby certify that the smoke alarms and carbon monoxide alarms have been installed in accordance with the manufacturer's instructions and in compliance with the code sections referenced above. I declare under penalty of perjury that the foregoing is true and correct, and that this declaration was executed on (Date) , II - 13 - ( 9 • , at Arcadia, California. Owner's Name (printed/typed): KAr1A, PPIIRT .t?Wu/ G1ae Signature of Owner: Ador This affidavit must be returned to the City of Arcadia inspector prior to final inspection / Si 0,_, AL_�^' ' W' . _' s P0' • IC - i'. = e _ ® 5 Guest RoomAli '•tstt6roo IStorage e . O N Family Room 111111 r; si • 't,Garage ks 9 FIRST FLOOR PLAN *= SMOKE ALARM V = CARBON MONOXIDE ALARM . - ' r l1_ Mstr - • Bath AMaster Bedroom Dining Room Kitchen Bath •t • Closes. Hall 0 { Closet - A Closet Family Room - ® ' 0 0 } ® 'a— Bedroom Bedroom SECOND FLOOR PLAN .0-4 SMOKE ALARM EI = CARBON MONOXIDE ALARM .