Loading...
HomeMy WebLinkAboutSOLAR-332 GENOA _ - reb4-o ' City of Arcadia, CA 0 Permit NO.SOLR-19-2083 Development Services Department S'P�� '-vv"'-`�I¢"1I':�f` Permit Type:Solar � w�^. 240 West Huntington Drive,Post Office Box 60021 7 T 1JJ�I 1 Arcadia,CA 91066-6021P}� Work Classihcallon•Solar-Residential (626)574-5416 _ Permit Maths:Issued ARCADIA Issuepate:lo%15/l019I Expiration: 04/12/2020 Addr NO. Dir Prefix Street Name Street Suffix Unit City,State,Zip Parcel Number 332 GENOA ST Arcadia,CA 91006-3929 5779019126 Contacts ZHOU,CHENG AND ZHANG,LI Owner AMERIGREEN BUILDERS INC Contractor 332 Genoa ST,Arcadia,CA 91107 16161 VENTURA BLVD 218,ENCINO,CA 91436 (844)704-7336 1023006 Description:ROOF MOUNTED SOLAR SYSTEM 17 MODULES 1 Valuation: $0.00 Tenant INVERTER Total Sq Feet: 0.00 Plan Check N Plan H Fees Amount payments Amount Paid Building Plan Check Fee Residential $50.00 Total Fees $308.24 Electrical Permit Issuance Fee $47.01 Cash/Receipt N REC-02792-19 $308.24 • Fire Plan Check Fee Residential $50.00 Amount Due: $0.00 Inverters $77.78 Panels $82.45 Solid Waste Management Fee 2 $1.00 Total: $308.24 4Z- GOPLtTMTlONSU—S-eg F�� CALLS FOR INS (�ccC/YEJ7 5i ts#At F3F? Gt�/L ApF#eo st for inspection by telephone at 626-574-5450. Leave a message requesting the address,timeframe and what inspection item is needed. This permit/plan review expires by time limitation and becomes null and • void if the work authorized by the permit is not commenced within 180 days from the date of issuance or if the permit is not obtained within 180 days from the date of plan submittal.This permit expires and becomes null and void if any work authorized by this permit is suspended or abandoned for 180 consecutive days or if no progressive work has been verified by a City of Arcadia building inspector for a period of 180 consecutive days. October 15, 2019 Issued By: Date October 15,2019 Page 1 of 1 k ;rs:.. PERMIT/PLAN REVIEW APPLICATION %iia Development Services Department,240 West Huntington Drive, Post Office Box 60021 Arcadia, CA 91066-6021, (626) 574-5416,Fax(626) 447-9173 City of Arcadia LICENSED CONTRACTOR'S DECLARATION WORKERS'COMPENSATION DECLARATION ❑ I hereby affirm under penalty of perjury that I am licensed under provisions of I hereby affirm under penalty of perjury one of the following: Chapter 9(commencing with Section 7000,of Division 3 of the Business and Professions Code, nd my license is in full force andq�effect.t1:1I have and will maintain a certificate of consent to self-insure for workers' License Class /License No. Io7i 9 Exp. Date t Si compensation, as provided for by Section 3700 of the Labor Code, for the a • performance of the work for which this permit is issued. Signature of Contractor `(fir OWNER-BUILDER DECLARATION [(] I have and will maintain workers'compensation insurance,as required by Section IDI hereby affirm under penalty of perjury that I am exempt from the Contractors 3700 of the Labor Code,for the performance of the work for which this permit License Law for the following reason(Section 7031.5,Business and Professions is issued.My workers'c mpensafion j{tsurance carrier aolicy numbare: Code.Any city or county which requires a permit to construct,alter,improve, Carrier 5 Q Qw. cN t 1 ` , Jers demolish,or repair any structure,prior to its issuance,also required the applicant 7 for such permit to file a signed statement that he or she is licensed pursuant to the I Policy Number `( a 7In/' provisions of the Contractors License Law(Chapter 9(commencing with Section (This section need not be completed if the permit is for onehundred dollars or less) 7000)of Division 3 of the Business and Professions Code)or that he or she is exempt there from and the basis for the alleged exemption. Any violation of ,r1I certify that in the performance of the work for which this permit is issued,I shall Section 7031.5 by any applicant for a permit subjects the applicant to a civil not employ any person in any manner so as to become subject to the workers' penalty of not more than five hundred dollars($500)): compensation Laws of California,and agree that if I should become subject to the workers'compensation provisions of Section 3700 of the Labor Code,I shall ❑I, as owner of the property, forthwith comply with those provisions. �� or my employees with wages as their sole compensation,will do the work,and the structure is not intended or offered for sale(Section 7044,Business and Professions Code:The Contractors License ate /0 (-trio_ Signature 'r Law does not apply to an owner of property who builds or improves thereon, or who does such work himself or herself or through his or her own - i employees,provided that such improvements are not intended or offered for WARNING: Failure to secure Workers'Compensation coverage is unlawful, sale.If,however,the building or improvement is sold within one(1)year of and shall subject an employer to criminal penalties and civil finesup to one completion,the owner-builder will have the burden of proving that he or she hundred thousand dollars($100,000),inaddition to the cost of compensation, did not build or improve for the purpose of sale). damages as provided for in Section 3706 of the Labor Code, interest, and attorney's fees. ❑I, as owner of the property, am exclusively contracting with licensed contractors to construct the project(Section 7044,Business and Professions Code:The Contractors License Law does not apply to an owner of property CONSTRUCTION LENDING AGENCY who builds or improves thereon,and who contracts for such projects with a I hereby affirm under penalty of perjury that there is a construction lending agency contractor(s)licensed pursuant to the Contractors License Law). for the performance of the work for which this permit is issued (Section 3097, Civil Code). U I am exempt under Section 7044,Business and Professions Code,for this reason: Lender's Name Date Signature Lender's Address IMPORTANT: APPLICATION IS HEREBY MADE TO THE BUILDING OFFICIAL FOR A PERMIT SUBJECT TO THE CONDITIONS AND RESTRICTIONS SET FORTH ON THIS APPLICATION AND THE FOLLOWING: 1. The City's approved plans and permit inspection card must remain on the job site for use by City inspection personnel. 2. Final inspection of the work authorized by this permit is required.A Certificate of Occupancy must be obtained prior to use and occupancy of new buildings and structures. 3. Per South Coast Air Quality Management District(AQMD)regulations,renovation and remodeling work that results in the removal,stripping,or altering of asbestos containing materials requires an asbestos survey and removal prior to disturbing the asbestos.Please contact AQMD at(909) 396-2000 for further information. Q Name CO V1. 14. I// P�V C err Lt Title 4 via i? ALS!i PawlN V I certify that I have read this application and state that the above information is correct and that I am the owner or duly authorized agent of the owner. I agree to comply with all City ordinances and State Laws relating to building construction. I hereby authorize representatives of the City of Arcadia to enter upon the above-mentioned property for inspection purposes. (Signature 77/4 11 hate Date 0 / /—r/ ®. f1-1�8r..., JJ.. 4‘,,,,00),,,A,v,4 , _ ._,___, Ill ♦ '^nu Cog,4"1,!^`NoF 6• AFFIDAVIT SELF-CERTIFICATION FOR COMPLIANCE OF SMOKE ALARMS AND CARBON MONOXIDE ALARMS Property Address: 3J. (, ,..zr S At/arb (C Permit Number: 5cs42 l9 -Zze53 Brief Job Description: tem-c' leenme sjl �cxAle ; 62 MopC.0 S / / eXe e Number of smoke alarms installed: Number of carbon monoxide alarms installed: c„,4,ho, One .54x,La Qa 6 When alterations, repairs or additions requiring a permit occur, or sleeping rooms are created, Smoke alarms shall be installed in each sleeping room, and outside each separate sleeping area in the immediate vicinity of the bedrooms, and on each additional story of the dwelling, including basements and habitable attics as required by Section R314 of the 2016 California Residential Code (CRC) and California Health and Safety Code Section 13113.7. For dwellings or sleeping units containing fuel burning appliances or having attached garages, carbon monoxide alarms shall be installed outside each separate sleeping area in the immediate vicinity of the bedrooms, and on each additional story of the dwelling, including basements as required by Section R315 of the of the 2016 California Residential Code (CRC). Multi-purpose alarms (combination carbon monoxide and smoke alarms) may be used. • All alarms shall comply with requirements for listing and approval by the Office of the State Fire Marshal. http://osfm.fire.ca.oov/licensinolistingsllicenselistino bml searchcotest.php As owner of the above referenced property, I hereby certify that the smoke alarms and carbon monoxide alarms have been installed in accordance with the manufacturer's instructions and in compliance with the code sections referenced above. I declare under penalty of perjury that the foregoing is true and correct, and that this declaration was executed on (Date) t 5-19 _ at Arcadia, California. Owner's Name (printed/typed): 42 2-H/aNC- Signature of Owner: ��i 2.--t-r---- This affidavit must be returned to the City of Arcadia inspector prior to final inspection SMOKE ALARM AND CARSON MONOXIDE ALARM LOCATIONS Guest Roan, h Bathrou I • storage I iFamily Room r s pasGarage L........------- FIRST FLOOR PLAN e= SMOKE ALARM I = CARBON MONOXIDE ALARM r I. I Mstr 1111, Bath -- AMaster Bedroom Dining Room Kitchen f _ lied 0 1 ball Closet Closet. -- Closet — Family Room a -- T _- ---: 0 0 --- Bedroom Bedroom SECOND FLOOR PLAN =SMOKE ALARM 1 =CARBON MONOXIDE ALARM • ) OFESSy N Built in 2013 �-e9ao�ESK4M�' wT IN Genoa Sl i W ��. Singe Family °a Li ssea y� 1 •1• E House: 1411 SQ.F v` ' • ° EKP. 12/18 £' • e e ° I Lot: 0.324 acres s.sr • ° ^ . ..'a IL I S B Tu.. I. P NEIGHBOUR'BUILDING " F� e _ or asr- I �_ a .. ._i_ a/ + .• . 30d.� a •r p a e e • • II w TYTT1E' C \. , 1 •• •� f17CanadianSolar325W - - ru. e /i////j/i//j /j/�j/�/j 1 • .17 P400 Power Optimizers� �i g' d s °°� .> i/�i/// // // / ! /i ///• • Tilt:18 Deg > p 0• //////j////j ///j////��/ .,.�( ,i1:-V.•:........,0-.. Azimuth:270D l:, e / / // / // //// //// Grp ,r--n'� .,1. / nt . • • •:, , , „ , „ `` e ° -1 a // /// /// ///.00 / J r NOTE:A 36-tnchwide pathwayshall be I• • o ?' // ///////// /// //////// ••• .'! ) / / / / / // // / // i J provided to the emergency l e° ° ° > a .�//j ///j /// /i// // •..J , escape and rescue opening. I ••-• — / // / / / /j / // / • All electrical work shall be designed per 2017 Los Angeles County I.• 39•a•_• - /./.0.////,/, // //// //� ...I Electrical Code, 2016 California Electrical Code, and 2014 National - • . • ///////// / // ///�/ •_ -1 • Electrical Code and 2016 Building Energy Efficiency Standards. f •• // / �// 4#/././/// / .-.I i 110,2 Approval: All electrical equipment shall be labeled, listed, I• - • e •• //// ///• ///// II or certified by aNationally-Recognized Testing Laboratory `• o ............... i i///O /0_ °Iii accredited by the United States Occupational Safety Health I.:.' . i///ii �� �,:-1 ^ Administration. 15- •6° . / / // / // / <, d PV ARRAY INDEX rr _ _ 1 SOLAR MODULES MSP (E) 200A Main Sento Panel ` -'-' -'- -- -- J 17 Canadian 325 Wad IN -IM HDWeve 8.0 kWlmerter �p 1 Model aCSiH-325M5 — w�y�y PHOTOVOLTAIC CON ' 'p, from,Gmon sour AC .(N)60A AC Disconnect._ LAYOUT INVERTER -" AmeriGr¶eIt PROPearrPLAN 18161 Ventura Blvd. Plnne:8447047338 i JB (N)JUMbn ear f Bubo ale.Encino,CA 81/38 1 INVERTER TYPE:Central: --_--. 0 51 10'• 9 O L A R ,,,,,,,��,,,,,,� Solar Edge HD Wave 6.0 kW Inverter EMTtypeCondut Isli . W ,. OeTE.4 ,, Zhou , ,Cheng LIca,ov008 Model aSE6000H-US(244bv) ——— s yr NOTE:CONDUIT SHALL BE PAINTED drawn M:Line TO MATCH EXISTING SURFACE. °"• 332 Genoa St Arcadia,CA Guy Gabay • mos . a �,� rLAGUNA 28202 Cabot Road, Suite 300 :;r CONSULTING ENGINEERS Laguna Niguel, CA 92677 ��� LPG, INC. 949-371-5238 info@LagunaEngineers.com October 14,2019 ttPiSESKASitiNte To: • Ameri Green Solar �416161 Ventura Blvd.Ste.218 y y QS 5847 r y Encino,CA.91436 w °-z m * EXP. 12/19 Subject: Certification Letter 1P trip .��`'� Zhou Residence 4 UCTU0�� 332 Genoa St ' OF C/C50- Digitally signed by Arcadia,CA.91006 I .._'1►4 Paymon Eskandanian Date:2019.10.15 To Whom It May Concern, 04:06:10-07'00' A jobsite observation of the condition of the existing framing system was performed by an audit team of Amen Green Solar as a request from Laguna Pacific Group.All review is based on these observations and the design criteria listed below and only deemed valid if provided information is true and accurate. On the above referenced project,the roof structural framing has been reviewed for additional loading due to the installation of the solar PV addition to the roof.The structural review only applies to the section of the roof that is directly supporting the solar PV system and its supporting elements.The observed roof framing is described below.If field conditions differ,contractor to notify engineer prior to starting construction. The roof structure of(Roof 1)consists of tile roof,sloped at 18 degrees.The roofing material is supported by roof plywood and by the roof framing below. The existing roof framing system of(Roof 1)is judged to be adequate to withstand the loading imposed by the installation of the solar panels.No reinforcement is necessary. The spacing of the solar standoffs should be kept at 48"o.c.for landscape and 48"o.c.for portrait orientation. The scope of this report is strictly limited to an evaluation of the fastener attachment,underlying framing and supporting structure only. All panels,racking and hardware shall be Installed per manufacturer specifications and within specified design limitations.All waterproofing shall be provided by the manufacturer. Laguna Pacific Group assumes no responsibility for misuse or improper installation of the solar PV panels or racking. Design Criteria: • Applicable Codes=2016 CBC,ASCE 7-10,and NDS-12 • Roof Dead Load=14 psf(Roof 1) • Roof Live Load=20 psf • Wind Speed=110 mph(Vult),Exposure C,Risk Category II • Attachments:2-5/16 dia.lag screw with 2.5 inch min embedment depth,at spacing shown above. Please contact me with any further questions or concerns regarding this project. Sincerely, Paymon Eskandanian,S.E. Principal Engineer Zhou Residence,Arcadia, CA.xlsm 1 , x a,a LAGUNA 28202 Cabot Road, Suite 300 ion CONSULTING ENGINEERS Laguna Niguel, CA 92677 'a` LPG, INC. 949-371-5238 info@LagunaEngineers.com Address: 332 Genoa St,Arcadia,CA.91006 Exposure: C Wind Speed: 110 mph Risk Category: II Aerial Image I ! y �7f, ` j Jar' s� • � � ` r ! 4,. "• ..- %. X11 ;- ` . t'(! `t „i '_ • j_1151 'Tp� . �a• s-� Cl .fir}^ ny aL� t —` ^s ,�' P 1 RIP '7 f t_, It ' :TM '! -,y". I , >t� ' t' g „i r) r l t ;di g , .' r �, ( ', OT „ 1 ;. r Irk l li I ` y.'?' 332 Genoa4'Sta. 't a y F4' i 1 11 , , 'O. , d t to ti. I. St '' I I. .r.1 1 i p 0�I.. L �'x, .fit: I I? 1 I. I if Ij�v. {r•F .7 iy ti Zhou Residence,Arcadia, CA.xlsm 2 �,o LAGUNA 28202 Cabot Road, Suite 300 :;: CONSULTING ENGINEERS Laguna Niguel, CA 92677 ',' LPG, INC. 949-371-5238 info@LagunaEngineers.com Gravity Loading PV Dead Load=3 psf(Per Ameri Green Solar) DL Adjusted to 18 Degree Slope 3.15 psf PV3ystem Weight',`c j Weight of PV System(Per Ameri Green Solar) 3.0 psf X Standoff Spacing= 4.00 ft Y Standoff Spacing= 2.75 ft Standoff Tributary Area= 11.00 sft f Point Loads of Standoffs 33 lb I Roof Live Load=20 psf Note:Roof live load is removed in area's covered by PV array. f Roof Dead Load(Roof 1)` Tile 10.00 Roof Plywood 2.00 Framing 1.52 Vaulted Ceiling 0.00 (Ceiling Not Vaulted) Miscellaneous 0.48 j Total Roof DL(Roof 1) 14.0 psf DL Adjusted to 18 Degree Slope 14.7 psf Zhou Residence,Arcadia, CA.xlsm 3 ,. �,• LAGUNA 28202 Cabot Road, Suite 300 �;' CONSULTING ENGINEERS Laguna Niguel, CA 92677 ••�, LPG, INC. 949-371-5238 info@LagunaEngineers.com Wind Calculations Per ASCE 7-10 Components and Cladding �;i` _npo ana es 1 Wind Speed 110 mph - Exposure Category C ' Roof Shape Gable/Hip Roof Slope 18 degrees Mean Roof Height 20 ft Effective Wind Area 19.3 ft es gni n i,ressun�cu a._ons Wind Pressure P=q h'G'Cn qh=0.00256'Kz'Kzt'Kd•V*2 (Eq.30.3-1) Kz(Exposure Coefficient)=0.9 _ (Table 30.3-1) Kzt(topographic factor)= 1 (Fig.26.8-1) Kd(Wind Directionality Factor)= 0.85 (Table 26.6-1) _ V(Design Wind Speed)=110 mph (Fig.26.5-1A) Risk Category= II (Table 1_.5-1) qh= 23.70 0.6 'gh= 14.22 tan_o_Lp _acua_ons;intrait Zone 1 Zone 2 Zone 3 Positive GCp= -0.84 -1.39 -2.23 038 (Fig.30.4-1) 'Uplift Pressure= -11.91 psf _ - -_19.76 psf -31.68 psf 10.0 psf (Minimum) X Standoff Spacing= 4.00 4.00 2.67 Y Standoff Spacing= 2.75 2.75 _ 2.75 TributaryArea= 11.00 _ 11.00 7.33 Footing Uplift= -131 lb -217 lb -232 lb an o__ p r ; a cu at ons3�an scape Zone 1 Zone 2 Zone 3 Positive GCp= -0.84 -1.39 -2.23 0.38 (Fig.30.4-1) Uplift Pressure= -11.91 psf -19.76 psf -31.68 psf 10.0 psf (Minimum) X Standoff Spacing= 4.00 4.00 2.67 . Y Standoff Spacing= 1.75 1.75 1.75 Tributary Area= - 7.00 7.00 4.67' • Footing Uplift= -83 lb -138 lb -148 lb n o jUp yec Maximum Design Uplift=-232 lb Standoff Uplift Capacity =450 lb 450 lb capacity>232 lb demand Therefore,OK 'alfittFastener,Capacily,OhackS Fastener=2-5/16 die.Lags Number of Fasteners=2 Embedment Depth=2.5 - Pullout Capacity Per Inch=250 lb • Fastener Capacity=1250 lb w/F.S.of1.58DOL of1.6=1334Ib 1334.4 lb capacity>232 lb demand Therefore,OK Zhou Residence,Arcadia, CA.xlsm 4 „i LAGUNA 28202 Cabot Road, Suite 300 . CONSULTING ENGINEERS Laguna Niguel, CA 92677 LPG, INC. 949-371-5238 info@LagunaEngineers.com Vertical Check Per CEBC Section 402.3 Sum arydiLoading: (E)Existing (N)with PV D(psi) 14.0 psf 17.0 psf PV DL=3 psf Lr(psf) 20.0 psi 0.0 psf (Under Panels Only) S(psf) 0.0 psf 0.0 psi 'Total Roof Gravity Load 34.0 psf 17.0 psf � %Change in Roof Gravity Load due to PV array addition %-DIFF=(N-E)/E =(17-34)134 %-DIFF= -50.00% (O.K.) Per the California Existing Building Code(CEBC)2016 Section 402.3,indicates that alterations to a building that result in less than 5%increase in the gravity loads may be performed without a structural evaluation of the existing building.The member forces in the area of the propsed solar array will not increase by more than 5%.Therefore,the requirements of section 3403.3 have been met and the proposed addition of solar PV is allowed with no further remediation. Zhou Residence,Arcadia, CA.xlsm 5 io LAGUNA 28202 Cabot Road, Suite 300 ,;e CONSULTING ENGINEERS Laguna Niguel, CA 92677 :0, LPG, INC. 949-371-5238 info@LagunaEngineers.com Lateral Check Per CEBC 2016 Chapter 34 Existing Weight of Effected Building Level Area Weight(psf) Weight(Ib) Roof 1400 sf 14.7 psf 20609 lb Ceiling 1400 sf 6.0 psf 8400 lb 718°Stucco , 100 ft 11.0 psf 4400 lb (8'-0°Wall Height) Int.Walls 100 ft 6.4 psf 2560 lb I Existing Weight of Effected Building 35969 lb Prbposed.Weight of PV System Weight of PV System(Per Amed Green Solar) 3.0 psf Approx.Area of Proposed PV System 309 sf I Approximate Total Weight of PV System 927 lb - 10%Comparison 10%of Existing Building Weight(Allowed) 3597 lb Approximate Weight of PV System(Actual) 927 lb Percent Increase 2.6% 3597Ib>927 lb,Therefore OK _f Zhou Residence,Arcadia, CA.xlsm 6