HomeMy WebLinkAboutUntitled City of Arcadia, CA Permit.No SOLR-19-1796
jP
Development Services Department D ( Permit Type:Solar
240 West Huntington Drive,Post Office Box 60021 11 �+ +') 1 I } -,
P
`. ` ! I Work Oass, cdtion:Solar-Residential Over 10 KV
Arcadia,CA 91066-6021 � �.�„�}�1s + t_�:-�� .� _ _
(626)574-5416 "` - - :Permit Status:Issued
ARCADIA Issuenate:09/06/2019 Expiration: 03/04/2020
Addr NO. Dir Prefix Street Name Street Suffix Unit City,State,Zip Parcel Number
145 Norman AVE Arcadia,CA 5782019037
Contacts
JENNIFER KOU SUNG&CHIENYEH SUNG Owner Sunside Solar Inc. Contractor
145 W NORMAN AVE 9040 Telstar AVE#128,El Monte,CA 91731
(888)997-8168 995897
Description:ROOF MOUNTED SOLAR SYSTEM 30 MODULES, Valuation: $ 0.00 Tenant
COMBINER BOX Total Sq Feet: 0.00 Plan Check# Plan It
Fees Amount payments Amount Paid
Building Plan Check Fee Residential 550.00 Total Fees $324.72
Distribution Panel $16.48 Cash/Receipt#REC-02401-19 $324.72
Electrical Permit Issuance Fee $47.01
Fire Plan Check Fee Residential $50.00 Amount Due: $0.00
Inverters $77.78 COFJPL!TE
Panels $82.45
Solid Waste Management Fee 2 $1.00
Total: $324.72
CALLS FOR INSPECTIONS
for inspection by telephone at 626-574-5450. Leave a message
17,40.C. 67
/! reRequestquesting the address,timeframe and what inspection item is needed.
This permit/plan review expires by time limitation and becomes null and
void if the work authorized by the permit is not commenced within 180 days
from the date of issuance or if the permit is not obtained within 180 days
from the date of plan submittal.This permit expires and becomes null and
void if any work authorized by this permit is suspended or abandoned for 180
consecutive days or if no progressive work has been verified by a City of
Arcadia building inspector for a period of 180 consecutive days.
(g- •
September 06, 2019
Issued By: Date
September 06,2019 Page 1 of 1
�JJro4Y4�
,x PERMIT/PLAN REVIEW APPLICATION
z�3*' Development Services Department,240 West Huntington Drive,Post Office Box 60021
moron orN
Arcadia, CA 91066-6021, (626) 574-5416,Fax (626) 447-9173
City of
Arcadia
LICENSED CONTRACTOR'S DECLARATION WORKERS'COMPENSATION DECLARATION
❑ I hereby affirm under penalty of perjury that I am licensed under provisions of I hereby affirm under penalty of perjury one of the following:
Chapter 9(commencing with Section 7000,of Division 3 of the Business and
Professions Code,an my license is in full fo e� 5Leffect / ❑ I have and will maintain a certificate of consent to self-insure for workers'
License Class License No. N 4 17 Exp. Date?l r/t¢f compensation, as provided for by Section 3700 of the Labor Code, for the
performance of the work for which this permit is issued.
Signature of Contractor
OWNER-BUILDER DECLARATI I - ❑ I have and will maintain workers'compensation insurance,as required by Section
❑ I hereby affirm under penalty of perjury that I am exempt from the Contractors 3700 of the Labor Code,for the performance of the work for which this permit
License Law for the following reason(Section 7031.5,Business and Professions is issued.My workers'compensattQ insurance c 'er and policy numbers are:
Code.Any city or county which requires a permit to construct,alter,improve, Carrier
demolish,or repair any structure,prior to its issuance,also required the applicant ``.
for such permit to file a signed statement that he or she is licensed pursuant to the Policy Number q t
provisions of the Contractors License Law(Chapter 9(commencing with Section (This section need not be completed if a permit is for one hundred dollars or less)
7000)of Division 3 of the Business and Professions Code)or that he or she is
exempt them from and the basis for the alleged exemption. Any violation of 0 I certify that in the performance of the work for which this permit is issued,I shall
Section 7031.5 by any applicant for a permit subjects the applicant to a civil not employ any person in any manner so as to become subject to the workers'
penalty of not more than five hundred dollars($500)): compensation Laws of California,and agree that if I should become subject to the
workers'compensation provisions of Section 3700 of the Labor Code,I shall
❑I, as owner of the property, forthwith c p y with those provisions.
or my employees with wages as their sole
compensation,will do the work,and the structure is not intended or offered for
sale(Section 7044,Business and Professions Code:The Contractors License Date i Signature
Law does not apply to an owner of property who builds or improves thereon,
or who does such work himself or herself or through his or her own
employees,provided that such improvements are not intended or offered for WARNING: Failure to secure Workers'Compensation coverage is unlawful,
sale.If,however,the building or improvement is sold within one(1)year of and shall subject an employer to criminal penalties and civil fines up to one
completion,the owner-builder will have the burden of proving that he or she hundred thousand dollars($100,000),in addition to the cost of compensation,
did not build or improve for the purpose of sale). damages as provided for in Section 3706 of the Labor Code, interest, and
attomey's fees.
❑I, as owner of the property, am exclusively contracting with licensed
contractors to construct the project(Section 7044,Business and Professions
Code:The Contractors License Law does not apply to an owner of property CONSTRUCTION LENDING AGENCY
who builds or improves thereon,and who contracts for such projects with a I hereby affirm under penalty of perjury that there is a construction lending agency
contractor(s)licensed pursuant to the Contractors License Law). for the performance of the work for which this permit is issued (Section 3097,
Civil Code).
❑ I am exempt under Section 7044,Business and Professions Code,for this reason:
1 r Lender's Name
Date '1 ((j I11 Signature y_tJ Lender's Address
IMPORTANT: APPLICATION IS HEREBY MADE TO THE BUILDING OFFICIAL FOR A PERMIT SUBJECT TO THE CONDITIONS AND
RESTRICTIONS SET FORTH ON THIS APPLICATION AND THE FOLLOWING:
1. The City's approved plans and permit inspection card must remain on the job site for use by City inspection personnel.
2. Final inspection of the work authorized by this permit is required.A Certificate of Occupancy must be obtained prior to use and occupancy of new buildings
and structures.
3. Per South Coast Air Quality Management District(AQMD)regulations,renovation and remodeling work that results in the removal,stripping,or altering
of asbestos containing materials requires an asbestos survey and removal prior to disturbing the asbestos.Please contact AQMD at(909) 396-2000 for
further information.-/
Name %Ph-• �G Title
✓✓✓✓llll PRNAME
I certify that I have read this application and state that the above information is correct and that I am the owner or duly authorized agent of the owner.
I agree to comply with all City ordinances and State Laws relating to building construction. I hereby authorize representatives of the City of
Arcadia to enter upon the above-mentioned property for inspection purposes.
Signature Date
q//13 .
GENERAL NOTES: NOTE:RAPID SHUTDOWN BUILT INTO EACH MICROINVERTER,NO ADDITIONAL RAPID SHUTDOWN EQUIPMENT REQUIRED. REVISION
O PV LAYOUT DATE NO
I.OUTDOOREQUIPAftNT SHALL BE AT LEASTNEMA]R RATED. SCALE:1/16°=II-O"
LACE SPECIFIED WIRING IS BASED ON TEE USE OP COPPER
I.CONTRACTOR SHALL OBTAIN ELECTRICAL PERMITS AND SHALL COORDINATE
AIL INSPECTION.COMMISSIONING AND ACCEPTANCE MIN THE CLIENT,
UHLRY CO.AND CITY INSPECTORS AS NEEDED.
4.DRAWINGS AREOIAORAMMATIC ONLY,ROUT NG OF RACEWAYS SHALL RR AT rra
THE OPTION OF THE CONTRACTOR UNLESS OTHERWISE NOTED ANO SHALL ER
COORDINATED WITH OTHER TRADES.
5.R DISTANCES OP CABLE RUNS ARE DIPFERE4TTAN SHOWN,TDR
CONTRACTOR SHALL NOTIFY ELECTRICAL ENGINEER N VALIDATE THE WIRE I (E)CABAIM
SIZE FINAL DRAWINGS WILL BE REDLINED AND UPDATED AS APPROPRIATE
6.WHENEVER A.DISCREPANCY IN QUANTITY OfEOUIPMENEARRES ON TEE I F
DRAWINGS OR SPECIFICATIONS,THECONIRACHIR SHALL BE RESPONSIBLE FOR
PROVIDING AND INSTALLING ALL MATERIAL AND SERVICES REQUIRED BY THE L_ w
STRICTEST CONDITIONS NOTED ON THE DRAWINGS OR IN TR SPECUICATUNS 11127 PVC Q
TO ENDURE COMPLIED:COMET IANCUAND LONGEVITY OVTROPURAUSE
SYSTEM REQUIRED BY THE ARCHITELTIENUER INEIEMERGED= I _TF
I.ALL BROCHURES.OPERATION MANUALS.CATAIu09:SHOP DRAWINGS,EIC. MOM TRELLIS �� I
(�VEN! y; 3Nm
SHALL BU HANDED OVER TO THEOWEIRS REPRESENTATIVE AT THE �
COASPLEHON OR WORK G
B.ALL CORING CONCEALED IN WALL AND CEILING SPACES SHALL BE IN METAL I ,E'ILY% 51 'STRING 1 z.�y reit,'
CONDUIT.
9.THE SEISMIC BRACING AND ANCHORAGE OF ELECTRICAL CONDUITS SHALL R� LEGEND m� "LgLgw
BE IN ACCORDANCE WITH THE•SMALTA-43UMLME9 FOR SEISMIC RESTRAINS STONE !$� II I 'I' N !i
1O.AL.OPTHE L LISTED
ND REQUIRED
ETHT SYSTEMSTHE SEISMIC
4—
(E)VMT I I ' LG I EIECIROFBC$ LGNONIC-A9 M 33CC
IO.ALLOYTNB LISTED SYSTEMS REQUIRRDTEATTHtl$EISNICLATERAL FORCE Tipry
P INCLUOINO@SNSIOERATT IE MAP AND 1W EU DETERMINED AT EACH LEVEL I 7,YDH 66.36'X40'%18
OP THE BUILDING SO THAT BRACE SPACING CAN BE CALCULATED.TISK
DISTRICT STRUCTURAL ENGINEER CAN APPROVE THE SEISMIC LATERAL FORCE (E)PAM ® ENPHASE COMBINER BOX
Q
DETERMINATION. jaiST
II.A COPY OP THE CHOSEN BRACING SYSTEM(S)INSTALLATION OUMP/MAMIAL G ® PERFORMANCE MONITOR < 'o
SHALL BE ON THE SITE PRIOR TO STARTING THE INSTALLING OF HANGERS �Qq 11 �/� - — P
ANIMA BRACES. —712 a 51 51 ,981[1 �/(�P•{Ep PTM IACid AC DISCONNECT/NAD SHUTDOWN CONTROLLER N s
ILWREN INSTALLING DRILLEOAN ANCHORS AND/OR POWDER DRIVEN PINS IN •elm ..i „ SI SI ® �^I' Wf w
EXISTING NON-PRESTRESSED REINFORCED CONCRETE USE CARE AND CAUTION ® ® TRAM SEANCE EIEC. PANEL ¢ g 9
TO AVOID CUTTING DR DAMAGING NE REINFORCED BARS.WHEN INSTALLING - — C1 51 M # JS
NUAfINTO EXISTING PRESTRESSED CONCRUIBTENDONS 0Y USING A `. on (E) EXISTING Z N pa
NONDESTRUCTIVE METHOD PRIOR TJ DISTALIATION.E%EROSE EXTREME >m 5I 5( Si
CARE AND CAUTION TO AVOID CUTTING OR DAMAGIA0NETENIIONS nURM0
INSTALLATION.MAIMAINAMINIMUM CLEARANCE GLOVE INCH BETWEEN NF. H ', 57 5.1 SP Cl PV SYSTEM: 30 X.344W - 10.20KW (DC) E en
REINFORCEMENT AND THE DAILLED.M ANCHOR.
Mpp2'E 7 ea ; �J
.T E WORKING CLEARANCES AROUND TUE }T3;1
O ELECTRICAL - SSI. 0 MODEL: LD ELECTRONICS L0340H1C-A5
EQUIPMENT AS WEU AS THE NEW ELECTRICAL EQUIPMENT WILL ER I " U ei 34CW PV PANEL SEE SHEET E-3 y
MAINTAINED IN ACCORDANCE WPM NEC 11026. ��A
II.SPACING MUST BE MAINTAINED BETWEEN ANT PLUMBING SEWER VENTS nm —y. 5 52. ® yDp� INVERTER: ENPHASE IDfROINVERIERS 107PW5-72-X-US
0%TO:DINO THROUGH THE ROOF AND TM UNDERSIDE OP THE PHOTOVOLTAIC _ 55IDpE SEE SHEET E-4
PANELS(V AGNHAUMRECOMMENDED). -D 12— ® RACKHG: SOLAR WAREHOUSE, SEE 5-1. 5-2 k 5-3
IS.SMOKE ALARMS AND CARBON MONOXIDE DETECTORS SHALL BE LOCATED co NEW qp�.. V.Ma SOLARIWARE OUSE SEE SHEET5-1. 5-1 t
AS REQUIRED PER SECTIONS 0.314 AR3IS WITHIN TIM CALIFORNIA RESIDENTIAL TyP. :,IY 1y Q<
CODE(CR Ly LIEU RAFTER: 2x6 0 T6'O.C.. ROOF RANTER VI 0°0wd 7
1 SYSTEM
ALARMS SOLELY TIM R.EM OPERATED TER WALL ANDLTAIC CEILI
61bTEM➢ T INVOLVE TIM REMOVAL OF INTERIOR WALLAND CEHJNG
FINISHES INSIDE THE Dom. F
IT.CONDUCTORS EXPOSED TO SUNLIGHT SHALL BE LISTED AS SUNLIGHT al
RESISTANT.(NECJIMb01,MA D) 6,T M M y ws-
IR.GROUNDING EMENDS ARE REQUIRED AROUND PRERLI71 HBD CONCENTRIC = E N 4 0
KNOCKOUTS ON THE DC SIDE OF THE SYSTEM.(NEC I10.9I) ® + a
0-
19.7 GROUNDING ELECTRODE CONDUCTOR MUST WI PROTECTED FROM N i mIr
PHYSICAL DAMACtl 1YSMALLSR THAN ISCOPPE0.WIRE.(NECIl0.61 El y;; ® �BL� - - 5el
SPLICES UDRroTS AT BUME MER WITHIN LISTED
BE UONTRT.(NEC25154 C) N .�����j _ Z
SPLICES URAlMT9 AT BUMMER WITHIN EQUIPMENT.(NEC 2lUN E] (L) 11P� Z Y
M.RACEWAY FURURUUNDING ELETRODE(UNDUCTOR SHALL BE BONDED AT \ - $ }LOPE W N i
EACH END.(CEO 25054(E) LyT^• *IF" O
22.EQUIPMENT OROUNDNO STALL BE INSTALL AT EACH INDIVIDUAL MODULE
AT THE MANUFACTURES HELD/AMENDED POINTE*ATTACHMENT USING A CIOICHETE
LISTED LUG SUITABLE FOR THAT PURPOSE(WITH ORWHHOUT WPEB ORRHUCO NS TILE
.•(GpE M/IV NE
CLIPS) VQ x.15 Rae:
�p� N'NITEO
23.ALL ROUSECONO[IT1'IHArReXPOsm IEIISTeEeADIIPDTR SALIE COLORASTHB "iiT2- pwR
HOUSE wAwDEaUun
24.DIRECTORY.APEIIICES ON OR INTER
DREITORYDENETISINO ALL Exit
ELECTRIC POWER SOURCES ON ORION AND PREMISESMUSTMUST RE INSTALLED AT A3
PACURP.RVICRP.IONSOUR LOCATION ANDALLINTERCONNECTED ELECTRIC
POWER PRODUCTION SOURCES.705.10