Loading...
HomeMy WebLinkAboutUntitled (2) City of Arcadia, CA - - Permit NO.SOLR-19-2436 t Development Services Department v Permi[Type:Solar 240 West Huntington Drive,Post Office Box 60021 i � f - Arcadia,CA 91066-6021ilWkCfossi�icotlo :Sol"ar-kesidentiaf I (626)574-5416 - Permit Status:issued ARCADIA . IssueDate:12/04/20191 Expiration: 06/01/2020 Addr NO. Dir Prefix Street Name Street Suffix Unit City,State,Zip Parcel Number 48 W WINNIE WAY Arcadia,CA 91007-8047 5782018024 Contacts DEXTER LEE Owner True Power Solar Contractor 48 W WINNIE WAY 201 Clark AVE, Pomona,CA 91767 (310)245-7154 (714)676-8888 970591 Description:ROOF MOUNTED SOLAR SYSTEM 16 MODULES, 1 Valuation: $ 0.00 Tenant INVERTER Total Sq Feet: 0.00 Plan Check N Plan 4 1 Fees Amount Payments Amount Paid Building Plan Check Fee Residential $50.00 Total Fees $308.24 Electrical Permit Issuance Fee $47.01 Cash/Receipt k REC-03260-19 $308.24 Fire Plan Check Fee Residential $50.00 Inverters $77.78 Amount Due: $0.00 Panels $82.45 Solid Waste Management Fee 2 $1.00 COLE1EDTotal: $308.24 ! ... fr..,/ CALLS FOR INSPECTIONS 6247-11 riti4-L Request for inspection by telephone at 626-574-5450. Leave a message requesting the address,timeframe and what inspection item is needed. GCrIFn Zfl&) -,10/<r DE7ccm ec firseF CAe06,41-15JI6)G S /7 %ACS kga 6r'4a 'LGgI7 This permit/plan review expires by time limitation and becomes null and void if the work authorized by the permit is not commenced within 180 days from the date of issuance or if the permit is not obtained within 180 days from the date of plan submittal.This permit expires and becomes null and void if any work authorized by this permit is suspended or abandoned for 180 consecutive days or if no progressive work has been verified by a City of Arcadia building inspector for a period of 180 consecutive days. 1/(7 December 04, 2019 Issued By: Date December 04,2019 Page 1 of 1 cN'Foy.vN 4 ;w�+ I= PERMIT/PLAN REVIEW APPLICATION •4l `11►*' o Development Services Department,240 West Huntington Drive,Post Office Box 60021 iii Arcadia, CA 91066-6021, (626) 574-5416,Fax(626) 447-9173 City of Arcadia LICENSED CONTRACTOR'S DECLARATION WORKERS'COMPENSATION DECLARATION ❑ I hereby affirm under penalty of perjury that I am licensed under provisions of I hereby affirm under penally of perjury one of the following: Chapter 9(commencing with Section 7000,of Division 3 of the Business and Professions Coda,and my/license is in full fore- , e / 0 I have and will maintain a certificate of consent to self-insure for workers' Ill License Class LJI--�b License No. 0)241 F . Date3/3l�ZD compensation, as provided for by Section 3700 of the Labor Code, for the • Signature of Contractor '� performance of the work for which this permit is issued. OWNER-BUILDER D y •TION ❑ I have and will maintain workers'compensation insurance,as required by Section 0 I hereby affirm under penalty of perjury that I am exempt from the Contractors 3700 of the Labor Code,for the performance of the work for which this permit License Law for the following reason(Section 7031.5,Business and Professions is issued.My workers�compsgtittn insurance carrier and policy numbers are: Code.Any city or county which requires a permit to construct,alter,improve, Carrier Li rr demolish,or repair any structure,prior to its issuance,also required the applicant t l{'7 6 • for such permit to file a signed statement that he or she is licensed pursuant to the Policy Number provisions of the Contractors License Law(Chapter 9(commencing with Section (This section need not be completed if the permit is for one hundred dollars or less) 7000)of Division 3 of the Business and Professions Code)or that he or she is exempt there fiom and the basis for the alleged exemption. Any violation of 0 I certify that in the performance of the work for which this permit is issued,I shall Section 7031.5 by any applicant for a permit subjects the applicant to a civil not employ any person in any manner so as to become subject to the workers' penalty of not more than five hundred dollars($500)): compensation Laws of California,and agree that if I she. d become subject to the workers'compensation provisions of Section 371 t labor Code,I shall 0 I, as owner of the property, or my employees with wages as their sole forthwith comply 'th those provisions. compensation,will do the work,and the structure is not intended or offered for r1 t Z f L( I Date Signature sale(Section 7044,Business and Professions Code:The Contractors License ` Law does not apply to an owner of property who builds or improves thereon, or who does such work himself or herself or through his or her own - employees,provided that such improvements are not intended or offered for WARNING: Failure to secure Workers'.Compensation coverage is unlawful, sale.If,however,the building or improvement is sold within one(1)year of and shall subject an employer to criminalpenalties and civil fines up to one completion,the owner-builder will have the burden of proving that he or she hundred thousand dollars($100,000),in addition to the cost of compensation, did not build or improve for the purpose of sale). damages as provided for in Section 3706 of the Labor Code, interest, and attorney's fees. ❑I, as owner of the property, am exclusively contracting with licensed contractors to construct the project(Section 7044,Business and Professions Code:The Contractors License Law does not apply to an owner of property CONSTRUCTION LENDING AGENCY who builds or improves thereon,and who contracts for such projects with a I hereby affirm under penalty of perjury that there is a construction lending agency contractor(s)licensed pursuant to the Contractors License Law). for the performance of the work for which this permit is issued(Section 3097, Civil Code). ❑ I am exempt under Section 7044,Business and Professions Code,for this reason: Lender's Name Date Signature Lender's Address IMPORTANT:APPLICATION IS HEREBY MADE TO THE BUILDING OFFICIAL FOR A PERMIT SUBJECT TO THE CONDITIONS AND RESTRICTIONS SET FORTH ON THIS APPLICATION AND THE FOLLOWING: 1. The City's approved plans and permit inspection card must remain on the job site for use by City inspection personnel. 2. Final inspection of the work authorized by this permit is required.A Certificate of Occupancy must be obtained prior to use and occupancy of new buildings and structures. 3. Per South Coast Air Quality Management District(AQMD)regulations,renovation and remodeling work that results in the removal,stripping,or altering of asbestos containing materials requires an asbestos survey and removal prior to disturbing the asbestos.Please contact AQMD at(909)396-2000 for further iinformat n. / _ 1 ame �"Is - l` �NAMEPRINT NAME \rrde -4 CC�v b`—...--,--,. I certify that I have read this applca>'on and state that the above information is correct and that I am the owner or duly authorized agent of the owner. I agree to comply with all Ci 4. •ii ,v .ces and State Laws relating to building construction. I hereby authorize representatives of the City of Arcadia to enter upon the : : 1 :, I, property for inspection purposes. 1Z1 L. / lg . ignature \teDa PHOTOVOLTAIC ARRAY Comota (16)Jinko Solar 390W PV Modules(JKM390M-72L-V) ROOF PLAN (1)Solar Edge 6.0 KW Inverter(SE6000H-US) (16)P400 Power Optimizers Dram By:RR A. UNIT INDEX MSP (E)Main Service Panel W Winnie Way INV (N)Inverter ACD (N)AC Disconnect JIB (N)Nema 3R Junction Box ICI Solar Module with Power Optimizer — EMT type conduit . . 11/471 36"Setback 4. r F7 , Pon mama. om 18"Setback Note:All exposed equip/conduit shall be painted to match roof/wail. CONTRACTOR Note:Existing roof tile lobe maintained. ET' True Power Solar Address: 201 Oa*Ave Tr....M.S.nre all Ttren.aZ.M.Irarik , Pomona.CA 91767 r A. 00 . 0 00000 7:1Fnene Number: 1 (MO 6764988 I-M WPM C-46 a a b b b b b .// Lice 970591 o ' /5 0 0 0 0 0 0 0 0 0 isttr 1. SOLAR TRUE POWER . 1 a a a a a a b b b . at: -- 0 0 701.1a1d-OP Cita" -.. Slo•0 Chan•e Line S• •c. .1 Solar Array 16 Jinko Soder 390W '16 P40170plimizers 'fl- Pitch:28 Deg - Orientation:18D De• ....sin— :0-* Dexter Lee • 48W Winnie Way„ I- Arcadia,CA 91007 FROM JUNCTION BOX TO ROOF EAVE EMT TYPE CONDUIT WILL RUN OVER .... — THE ROOF AT 31)2'HEIGHT,THEN UNDER THE EAVE TO PV EQUIPMENT SCALE ....n°2.2411 NOTE:FIRE CODE REFLECTS UPDATES FROM INTERVENING CODE CYCLE,EFFECTIVE 1 JULY 2018. I i i I ii— OS INDICATED 1 .. FIRE SETBACKS AND PATHWAYS COMPLY WITH IRC Ft324.6.1,R324.6.2,R324.7.26,AND IFC 1204.2.1.1,1204.2.1.2,AND 1204.2.1.3, 01 5 10 f . . , ' , T A P I:1 L L U 4650 E.ARROW HWY.STE.A7 STRUCTURAL MONTCLAIR, CA 91763 Structural Calculations for: _ Dexter Lee Residence 6.24 kW DC Photovoltaic Array Addition 48 W. Winnie Way Arcadia, CA 91007 Owner/Developer: co o True Power Solar z a ¢ 201 Clark Ave. x LEI tt < "' o Pomona, CA 91767 "z � mzIt Cf) V o wz • a2 I o °' uD °�� i` o c 2 - December 3, 2019 5;6;9 ! w O �', I a \ '•40*-YarI ILI w z 0 I I+' oi�0�I ! I a a Job#: 192137 -•I ca, 1 1 w a al I I , 5 9 9FEss/p h ,. T. cb, F -->v �o �n wiz 'V ��3� ` mQ m , ,a e, . Y1 N•.C75;95 f;�� CCJ I%.41mo 04 :,\,,,,?,, J EXP.N ORO 41 _ /�Q J' /[ ENG% \P rJ z �IR J o idi L o5 8 u LC m i ;EE S w 13 a w m S a i_ 1 of 4 r t . t A P L L 14650 E.ARROW HWY.STE.A7 STRUCTURAL MONTCLAIR.CA 91763 SOLAR RESIDENTIAL ROOF/BUILDING CHECK Check Photovoltaic Array Addition-2016 California Building Code(CBC) Gravity Design Loads: Roof Type: Flat concrete tile over 1/2"sheathing over trusses over 5/8"gypsum board Live Load: 20.0 psf Dead Load: Roofing Material: 12.0 psf Sheathing: 1.5 psf Roof Framing Members: 2.5 psf Drywall: 1.5 psf Insulation: 1.0 psf Miscellaneous: 1.5 psf 'Solar 5o lar Array&Rack System -- 2.91...,psf —Additional Load Applied Roof Dead Load w/o Solar Array= 20.00 psf Over<S0%of Roof Area Roof Dead Load at Solar Array= 22.91 psf Total Roof Load w/o Solar Array= 40.0 psf Total Roof Load at Solar Array= 42.9 psf Area of Solar Array Addition(for gravity check)=1—336 fta Total Area of Affected Trusses(for gravity check). 2000 , ft2 Area of Solar Array Addition(for seismic check)= 336. ft' Total Area of Affected Roof(for seismic check)= 2000 ft2 Check Additional Gravity Loads on Trusses: • Total Load Increase at Affected Trusses= 0.49 psf • %of Total Load Increase= 1.22% <5.0% OK Per CSC 3403A3 Additional Solar Array Weight Is Structurally I Acceptable Check Check Additional Gravity Loads on Lateral Resisting System: Dead Load Increase at Entire Roof= 0.49 psf %Dead Load Increase on Entire Roof= 2.44% < 10.0% OK Per CBC 3403A.4 Additional Solar Array Lateral Load Is StructurallyI Acceptable 2 of 4 • Sht: El APOLLO 4650 E.ARROW HWY, STE.A7 Date: - STRUCTURAL MONTCLAIR, CA 91763 #: . ROOF MOUNTED SOLAR PANELS i� Earthquake De—sign per ASCE 7-16-.13.3.1 Design Parameters Site Class1 D Per Table 16130.3.2 Latitude,deg Longitude,deg Short Period S.A.,5,=I -2.555', 2015 NEHRP Provisions �. 34.1406. A 118.0333', Site Coefficient,Fa= 1.20 Table 16130.3.3(1) Sms=F,55= 3.07 EQ 16A-37 Sos=2/3 Sms= 2.04 EQ 16A-39 Importance Factor,I,= 1.00 Section 13.1.3 Height of Equipment,z= - 12.00':3ft Height of Roof,h= 12 00 ft Weight of Panels to each Mount,WP=1 49.60a lbs a = 1.00 Table 13.6-1 RP= 2.50 Table 13.6-1 Determine Fp,Seismic Design Force(STRENGTH LEVELI Fp=(0.4apSosWp)(1+2z/h)/(RP/id= 49 lbs EQ 13.3-1 [Not Greater Than:] F,=1.6SpsWPIP= 162 lbs EQ 13.3-2 [Not Less Than:] Fp=0.3SosWPIP= 30 lbs EQ 13.3-3 Use FP= 49 ' nos at each Roof Mount Bracket 3 of 4 Sht: W1 APOLLO4650 E.ARROW HWY.STE.A7 Date: __ STRUCTURAL MONTCLAIR. GA 91763 e. ;• ROOF MOUNTED SOLAR PANELS I I ____,t:,µR Componentsand Cladding Wmdipad Design per ASGE 7.16,30.4.2 h<60 fi 1 Design Parameters i Design Wind Velocity(3s Gust),V= 110' mph Wind Exposure= -c" Mean Panel Height= 12.00 . rft Total Effective Area of Typical Array= 336 ft2 , Panel Area to Each Support= 21.00 ft2 Angle of Panels= 28ddegrees a= - 3 'Elft(3ft.Min.) Determine Wind Force at Each Roof Mount en=0.00256 K2 Kn Kd V2 I= 13.4 psf Load case 0.6°qn K2=70:85 iTable 30.3-1,Page 317 Ka= 1.0 Figure 26.8-1,Page 252-253 Kd= 0.85 Table 26.6-1,Page 250 1= 1.00 Internal Pressure Coeff.=6;= 0 +/-(Figure 6-5) v=0° v=1_80° GCP(Zone 1)_ ' 030 x-0.90 1Per Figures 30.4-1 thru 30.4-7 GCP(Zone 2)= '0.90 '-1.1I 0 Per Figures 30.4-1 thru 30.4-7 G;(Zone 3)= ° 1.00. , ^..1.20. 1NO PANELS IN ZONES (+)P=qh(GCP-GCPI)= 12.1 -14.8 psf,Positive Wind(10 psf min)-Worst Case Lateral Load at Each Mount= 119 -146 lbs Compression/Uplift at Each Mount= 224 -274 lbs i Roof Mount is attached to Mot sheathing&roof membersw/'(1)5/16"x 3:5"Lag Bolt w/Mm.y2 5"thread embed' perTRUE POWER SOLAR. ....,_— , 1 ___:.:J.,..._ - "Allowable:Loads for 5/16"Diameter Lag Screw per the 2015 NDS $ (Table 11.2A) Withdrawl= 266 lb/in x 2.5"embed x (Cd=1.6)= 1064 lbs (Table 11K) Shear= . 130 ' lb x (Cd=1.6) = 208 lbs " " , SOLAR ARRAY ATTACHMENT'METHOD IS STRUCTURALLY ACCEPTABLE. i. a 4 of 4