Loading...
HomeMy WebLinkAboutSOLR-20-0096 '-" 1 r Permit No SOLR 20 0096 City of Arcadia, CA , ,14; FPIr, Development Services Department ' 1_ •'°++'``•=.''''',.,“--;,;-'� , i`� '; Permlt�Type Solar i a A 240 West Huntington Drive,Post Office Box 60021 ,) 1 ,:1 ,', i 9 r ,, , '.,tr a Work Classification•Solar Residential Over 10 KV -r,,..;',„3:4:;"1Arcadia,CA 91066-6021 } ;Z .i•. (626)574-5416 ,r.. ,4 4 Permit Status Issued ARCADIA issue Date 01/16/2020] Expiration: 07/14/2020 Addr NO. Dir Prefix Street Name Street Suffix Unit City,State,Zip Parcel Number • 1049 OAKDALE LN Arcadia,CA 91006-2223 5770028001 Contacts JAVELLANA,JOSE AND ANGELINA TRS V5 Owner FIRST AMERICAN SOLAR Contractor TRUST 2100 MONROSE AVE 291, MONTOROSE,CA 91020 1049 OAKDALE LN (877)535-9992 1009839 Description:ROOF MOUNT PV SYSTEM, 32 MODULES/MICRO t Valuation: $ 0.00 Tenant f. INVERTERS,NEW 100 AMP SUBPANEL,DERATE MCB 175 AMP, i N ELECTRICAL LOAD CALCS INCLUDED.(REROOF HOUSE UNDER r Total Sq Feet: 0.00 Plan Check# Plan# , SEPARATE PERMIT g Fees Amount Payments Amount Paid Building Plan Check Fee Residential $50.00 Total Fees $324.72 Distribution Panel $16.48 Cash/Receipt#REC-03614-20 $324.72 Electrical Permit Issuance Fee $47.01 Fire Plan Check Fee Residential $50.00 Amount Due: $0.00 Inverters $77.78 Panels $82.45 Solid Waste Management Fee 2 $1.00 Total: $324.72 compuiTED ?, 1? (?-0- Sf17/4( ie`P¢ e CALLS FOR INSPECTIONS Request for inspection by telephone at 626-574-5450. Leave a message requestin the address, 'mef a and what inspection item is needed. /710A-e i9ea-/-eir szf-- (74f ,c„, Ay/4 This permit/plan review expires by time limitation and becomes null and void if the work authorized by the permit is not commenced within 180 days from the date of issuance or if the permit is not obtained within 180 days from the date of plan submittal.This permit expires and becomes null and void if any work authorized by this permit is suspended or abandoned for 180 consecutive days or if no progressive work has been verified by a City of Arcadia building inspector for a period of 180 consecutive days. January 16, 2020 Issued By: Date January 16,2020 Page 1 of 1 OFOJ Q .,iF01�.�9'd °� < l PERMIT/PLAN REVIEW APPLICATION `.E Development Services Department,240 West Huntington Drive,Post Office Box 60021 % YArcadia, CA 91066-6021, (626) 574-5416,Fax (626) 447-9173 City of Arcadia CENSED CONTRACTOR'S DECLARATION WORKERS'COMPENSATION DECLARATION hereby affirm under penalty of perjury that I am licensed under provisions of I hereby affirm under penalty of perjury one of the following: Chapter 9(commencing with Section 7000,of Division 3 of the Business and Professions Code,and my license is in full force and effect. 0 I have and will maintain a certificate of consent to self-insure for workers' License Class 6 License No./00 q&'J Exp. Date/z"3/-2.•Z/ compensation, as provided for by Section 3700 of the Labor Code, for the Signature of Contractor ,_Zrperformance of the work for which this permit is issued. OWNER-BUILDER DECLARATION I have and will maintain workers'compensation insurance,as required by Section ❑ I hereby affirm under penalty of perjury that I am exempt from the Contractors f the Labor Code,for the performance of the work for which this permit License Law for the following reason(Section 7031.5,Business and Professions is issued.My workers'compensation insurance carrier and policy numbers are: Code.Any city or county which requires a permit to construct,alter,improve, Carrier t � /� demolish,or repair any structure,prior to its issuance,also required the applicant Policy Number for such permit to file a signed statement that he or she is licensed pursuant to the provisions of the Contractors License Law(Chapter 9(commencing with Section (Ts section need not be completed if the permit is for one hundred dollars or less) 7000)of Division 3 of the Business and Professions Code) or that he or she is exempt there from and the basis for the alleged exemption. Any violation of 0 I certify that in the performance of the work for which this permit is issued,I shall Section 7031.5 by any applicant for a permit subjects the applicant to a civil not employ any person in any manner so as to become subject to the workers' penalty of not more than five hundred dollars($500)): compensation Laws of California,and agree that if I should become subject to the workers'compensation provisions of Section 3700 of the Labor Code,I shall ❑I, as owner of the property, or my employees with wages as their sole forthwith comply with those provisions. compensation,will do the work,and the structure is not intended or offered for sale(Section 7044,Business and Professions Code:The Contractors License Date O(-a.-Z°2v Signature Law does not apply to an owner of property who builds or improves thereon, or who does such work himself or herself or through his or her own employees,provided that such improvements are not intended or offered for WARNING: Failure to secure Workers'Compensation coverage is unlawful, sale.If,however,the building or improvement is sold within one(1)year of and shall subject an employer to criminal penalties and civilfines up to one completion,the owner-builder will have the liurden of proving that he or she hundred thousand dollars($100,000),in addition to the cost of,compensation, did not build or improve for the purpose of sale). damages as provided for in Section 3706 of the Labor Code, interest, and attorney's fees. 0 I, as owner of the property, am exclusively contracting with licensed contractors to construct the project(Section 7044,Business and Professions Code:The Contractors License Law does not apply to an owner of property CONSTRUCTION LENDING AGENCY who builds or improves thereon,and who contracts for such projects with a I hereby affirm under penalty of perjury that there is a construction lending agency contractor(s)licensed pursuant to the Contractors License Law). for the performance of the work for which this permit is issued (Section 3097, Civil Code). ❑ I am exempt under Section 7044,Business and Professions Code,for this reason: Lender's Name Date Signature Lender's Address IMPORTANT: APPLICATION IS HEREBY MADE TO THE BUILDING OFFICIAL FOR A PERMIT SUBJECT TO THE CONDITIONS AND RESTRICTIONS SET FORTH ON THIS APPLICATION AND THE FOLLOWING: 1. The City's approved plans and permit inspection card must remain on the job site for use by City inspection personnel. 2. Final inspection of the work authorized by this permit is required.A Certificate of Occupancy must be obtained prior to use and occupancy of new buildings and structures. 3. Per South Coast Air Quality Management District(AQMD)regulations,renovation and remodeling work that results in the removal,stripping,or altering of asbestos containing materials requires an asbestos survey and removal prior to disturbing the asbestos.Please contact AQMD at(909)396-2000 for further information. Name a/u'/7U 7 �/r�Z�A��� Title ���� PRINT NAME I certify that I have read this application and state that the above information is correct and that I am the owner or duly authorized agent of the owner. I agree to comply with all City ordinances and State Laws relating to building construction. I hereby authorize representatives of the City of Arcadia to enter upon the above-mentioned property for inspection purposes. e Date 0 (—/'- 50 a • MODULE TYPE,DIMENSIONS&WEIGHT ' ROOF DESCRIPTION NUMBER OF MODULES=32 MODULES : MODULE TYPE=HANWA O.PEAK DUO-05(315W)MODULES ROOF TYPE COMPOSITE SHINGLE FIRST �^ MODULE WEIGHT=41.2 LBS/18.7 KG. ROOF • ROOF TILT AZIMUTH• RAFTER RAFTER MODULE DIMENSIONS=66.3"x 39.4"=18.14 SF _ SIZE SPACING AMERICAN '' UNIT WEIGHT OF ARRAY=2.27 PSF El 18.00° 90° 2' 6" 24O.C. y^��+ FF #2 18.00° 180° 7xx6" 24'"O.C. S1V AR `. ARRAY AREA WITH TOTAL ROOF AREA ----- ROOF "— ROOF ' First American Solar W FOOTHILL BLVD (E)CHIMNEY #OF ARRAY AREAROOF AREA Tonyanyan ROOF AREA COVERED 2100 Montroserose Avenue#291, MODULES (Sq.Ft.) (Sq.Ft.) BY ARRAY Montrose,CA 91020 3'-0",r / 11'-2" / 8'-10"I' (90 wfwi.FirstAmerIcanSoiar.com Into@FlrstAme rlcanSoia r.com #1 22 399.08 1138.06 35.07 Ph No.877-535-9992 'l #2 10 181.40 391.SD 48.33 Contredor License#8 Typo: N- ____ CSLB B 1009839 36"FIRESETE ACK. ° I REVISIONS • ----.---6- s---OI- DESCRIPTION DATE BEV I INITIAL DESIGN ----■-4. *-4- 3.-0" - 3'-0" / / 20,-1"----",—8'-11" im1•- -• 1- r Signature with Seal i i i 36°FRISTBACFt D r\ IIll : rI 0 • --_ FM = M I i 1 1 1I I Om - �D Nm _,_y_.1-i__ t-1_t__y_ yO C) ' I -41_k I I I J °-� - - � k_ -Ifel O yI 1 1 1 I I .a _ D PROJECT NAME 8 ADDRESS r — i A • .t___.- 71 O � ,r 394" F+ ROOF x.� -- - _= .---- - Q (n ://m. -180 D< �-, Q o (16)APS YC600 w VL__•_ ` - __ COril MICROERTERS __ g Q CO (N)IRON RIDGE RACKING ____ __ ___ _ z ° O SYSTEM(TYP.) : W -I N- MI - O Q n (60)IRONRIDGE L-FOOT ATTACHMENT @ 48"O.C. .sk-- t ,e ____ HANWA O,PEAK 0¢ Q O ROOF 42 O ROT�B DUO-G5(315W) W rn ❑Z (10) HANWAO,PEAK I AZIM.-90' MODULES CO o V a DUO-05(315W)MODULES °P O ______I_ O 1 LEGEND a _3_6°FIRE SETBACK JB -JUNCTION BOX m APB QM -UTILITY METER (E)UTILITY METER El -MAIN SERVICE PANEL N (E)MAIN SERVICE PANEL J — (N)JUNCTION BOX TYP. SHEET NAME ACO -AC DISCONNECT ROOF PLAN& (N)AC PANEL BOARD ROOF#1 — (N)3/4"EMT CONDUIT RUN ON ROOF I (22)HANWA O.PEAK Ti -AC PANEL BOARD MODULES ,' DUO-G5(315W)MODULES ® -MICRO INVERTER SHEET SIZE 0® -VENTS,CHIMNEY(ROOF OBSTRUCTION) ANSI B 1 1 ROOF PLAN & MODULES • -ROOF ATTACHMENT 111'X 171' ---- -RAFTERS SHEET NUMBER PV-2 SCALE:3/32"=1'-0" ---- -CONDUIT PV_2 Wil ; :. 4 '"r- ,o...c..m.e r:,.7• i Aul.e7. f01 , r� P G4.i %=y,oi0�• AFFIDAVIT SELF-CERTIFICATION FOR COMPLIANCE OF SMOKE ALARMS AND CARBON MONOXIDE ALARMS Property Address: /C1 y/ , c'a� Ate- i r c,-,-- 6A % /c o6 Permit Number: So((Pr -- 00 Brief Job Description: /ea0/i7vf So L" Number of smoke alarms installed: - (f- Number of carbonmonoxide alarms installed: `Z When alterations, repairs or additions requiring a permit occur,or sleeping rooms are created, Smoke alarms shall be installed in each sleeping room, and outside each separate sleeping area in the immediate vicinity of the bedrooms, and on each additional story of the dwelling, including basements and habitable attics as required by Section R314 of the 2016 California Residential Code (CRC) and California Health and Safety Code Section 13113.7. For dwellings or sleeping units containing fuel burning appliances-or having attached garages, carbon Monoxide alarms :shall be installed outside each separate sleeping area in the immediate vicinity of the bedrooms, and on each additional story of the dwelling,. including basements asrequired by Section R315 of the of the 2016 California : Residential Code (,CRC). Multi-purpose alarms (combination carbon monoxide and smoke alarms) may be used. All alarms shall comply with requirements for listing and approval by the Office of the State Fire Marshal. htt.:Poem:fire.ca.•ov/licensin•listin•s/licenselistiin• brill searchcotest.•h• As owner of the above referenced property, I hereby certify that the smoke alarms and carbon monoxide alarms have been installed in accordance with the manufacturer's instructions and in compliance with the code sections referenced above. I declare under penalty of perjury that the f:.regoing is true and correct, and that this declaration was executed on (Date) .. at Arcadia, California. -, .����� PIE �A V(���ray¢ Owner's Name (printed/°:=ped)e Siignatdre of Owner: _:_ i This affidavit must be returned to the City of Arcadia inspector prior to final inspection , 1I� 0 ttttr aun!, -, Iill ' Storage rrtiiy i �ao`n � . FIRST FLOOR PLAN C.:w SMOKE ALARM := CARBON MONOXIDE ALARM . ns r i I Closet Balt G Ei ,1 Closet fp��o9qppqq �p _ l 1o�M� { ,_. i --- !tel - Family! Wain , . SEC*EkID FLOOR PLAN , • SMOKE ALARM C :. a CARSON MONOXIDE ALAR 1 f CUSTOMER NAME: JoseJavellana ADDRESS: 1049 Oakdale Ave,Arcadia,CA91006 RESIDENTIAL LOAD CALULATION FOR EXISTING DWELLINGS : . u •.2,065 SQ. FT.X3 VA ;;''' ;;6195; VA • 2 SMALL APPLIANCE BRANCH CIRCUITS VA 1 LAUNDRY CIRCUIT(WASHER) 150.0 VA 5,760 Oven 5760. VA OVA , .OVA , 0 VA �0 VA .:;: .0 VA • 0 VA _0 0 VA 0 VA 0 VA :0 VA Q VA `0 VA SPA ,0 VA POOL PUMP . `:0 VA TOTAL LOAD GROSS(VA) 16455,:TOTAL VA:. FIRST 10,000VA,VAX 100% °'"`10000 VA REMAINDER ABOVE 10,000 VAX 40% ',,2582 VA TOTAL LOAD NET(VA) Y'.'12582' VA TOTAL LOAD(AMPS) (VA/240V) 52.4 AMPS. AIR CONDITIONING LOADS 40 1-A/C MIN. CIRCUIT AMPS •,,7680' VA 30 2-A/C MIN.CIRCUIT AMPS `,;5760,, VA 0 3-A/C MIN.CIRCUIT AMPS • : -0 VA 0 4-A/C MIN.CIRCUIT AMPS g`'0 VA 0 HEAT PUMP MIN.CIRCUITAMPS0 VA 0 AHU VA(Breaker Amps X Volts X 80%) • .,,0, TOTAL A/C LOAD(VA) • : 13440,TOTALVA,, TOTAL LOAD(AMPS) (VA/240V) 56 AMPS TOTAL DEMAND(AMPS) I' 1.08.4 AMPS CUSTOMER NAME: JoseJavellana ADDRESS: 1049 Oakdale Ave,Arcadia,CA91006 RESIDENTIALLOAD`CALULATIO`N FORS-EXISTING'"DWELLINGS :2,065 SQ. FT.X 3 VA 6195 VA ' 2 SMALL APPLIANCE BRANCH CIRCUITS 3 VA mom • 1 LAUNDRY CIRCUIT(WASHER) "-"';°..1500 VA 5,760 Oven : 57,6 VA -0 VA OVA VA 0 VA r0' VA r:`0 VA ;A VA 1.1 1 I , SPA ' 0 VA • POOL PUMP 0 VA TOTAL LOAD GROSS(VA) >''16455, TOTAL VA FIRST 10,000VA,VAX 100% F':��A0000VA REMAINDER ABOVE 10,000 VAX 40% • -2582 VA TOTAL LOAD NET(VA) 42582 VA TOTAL LOAD AMPS 240V 52.4 AMPS AIR CONDITIONING LOADS 40 1-A/C MIN.CIRCUIT AMPS .a=7680; VA 3,0 2-A/CMIN.CIRCUITAMPS :'.5760 VA 0 3-A/C MIN.CIRCUIT AMPS : 0 VA 0 4-A/C MIN.CIRCUIT AMPS '<:0 VA 0 HEAT PUMP MIN.CIRCUITAMPS '0' VA 0 AHU VA(Breaker Amps X Volts X 80%) '0 TOTAL A/C LOAD(VA) -13440 -TOTAL VA. TOTAL LOAD(AMPS) (VA/240V) 56 AMPS TOTAL DEMAND(AMPS) I 108.4 AMPS 6" City of Arcadia, CA Permit No SOLR 19 1887 :‘4.711-7.1,V, Development Services Department qty . — " Permit Type Solar i 240 West Huntington Drive,Post Office Box 60021 ",1 l � t �.j �ti � Arcadia,ca 91066-6021 U - , r i t f WorkClassAation Solar lkes dential�° (626)574-5416 Permit Status Issued ARCADIA Issue Date:09/17/2019,, Expiration: 03/15/2020 Addr NO. Dir Prefix Street Name Street Suffix Unit City,State,Zip Parcel Number 1049 Oakdale LN Arcadia, CA 5770028001 Contacts JAVELLANA,JOSE AND'ANGELINA TRS V5 Owner DBA GREENSPIRE CONSTRUCTION Contractor TRUST 3130 WILSHIRE BLVD 200,SANTA MONICA,CA 90403 1049 OAKDALE LN (310)477-7686 1018241 Description:ROOF MOUNT PV SYSTEM 28 MODULES/1 Valuation: $ 0.00 Tenant INVERTER Total Sq Feet: 0.00 Plan Check# Plan# Fees Amount ' payments Amount Paid Building Plan Check Fee Residential $50.00 Total Fees $308.24 Electrical Permit Issuance Fee $47.01 Cash/Receipt#REC-02513-19 $308.24 Fire Plan Check Fee Residential $50.00 Amount Due: $0.00 Inverters $77.78 Panels $82.45 Solid Waste Management Fee 2 $1.00 Total: $308.24 ex PI RE 2 s /q Z CALLS FOR INSPECTIONS Request for inspection by telephone at 626-574-5450. Leave a message requesting the address,timeframe and what inspection item is needed. This permit/plan review expires by time limitation and becomes null and void if the work authorized by the permit is not commenced within 180 days from the date of issuance or if the permit is not obtained within 180 days from the date of plan submittal.This permit expires and becomes null and void if any work authorized by this permit is suspended or abandoned for 180 consecutive days or if no progressive work has been verified by a City of Arcadia building inspector for a period of 180 consecutive days. September 17, 2019 Issued By: Date September 17,2019 Page 1 of 1 Of Ano O�40,uF wv9',er �,s 7 PERMIT/PLAT REVIEW APPLICATION , 41j` Development Services Department,240 West Huntington Drive,Post Office Box 60021 ,.unity air Arcadia, CA 91066-6021, (626) 574-5416,Fax (626) 447-9173 City of Arcadia ICENSED CONTRACTOR'S DECLARATION WORKERS'COMPENSATION DECLARATION R® I hereby affirm under penalty of perjury that I am licensed under provisions of I hereby affirm under penalty of perjury one of the following: Chapter 9(commencing with Section 7000,of Division 3 of the Business and Professions Code,and m )icense is in full force and effect. " have and will maintain a certificate of consent to self-insure for workers' 1 License Class j-( G� Licei.e , 1. /O(, 2 Gr� Exp. Date 9- 17-/9 compensation, as provided for by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. }� Signature of Contractor �� � +j A OWNER-BUILDER DECLARATION A ;-..'i ave and will maintain workers'compensation insurance,as required by Section ? r 3700 of the Labor Code,for the performance of the work for which this permit ❑ I hereby affirm under penalty of perjury that I am exempt from the Contractors i ., a 6: is issued.My wor ers'com ensati n insurance carrier and policy numbers are: License Law for the following reason(Section 7031.5,Business and Professions f Code.Anycityor countywhich requires apermit to construct,alter,im rove 1,Ili Carrier 5f�,OJt e_ +Pteket q P � �-,; // demolish,or repair any structure,prior to its issuance,also required the applicant -�,1 67 2 o o) 3(7 3 for such permit to file a signed statement that he or she is licensed pursuant to the\ 't Policy Number ,1 i; (This section need not be completed if the permit is for one hundred dollars or less) provisions of the Contractors License Law(Chapter 9(commencing with Section.,l r 7000)of Division 3 of the Business and Professions Code)or that he or she is` exempt there from and the basis for the alleged exemption. Any violation of `t❑ I certify that in the performance of the work for which this permit is issued,I shall Section 7031.5 by any applicant for a permit subjects the applicant to a civil not employ any person in any manner so as to become subject to the workers' penalty of not more than five hundred dollars($500)): compensation Laws of California,and agree that if I should become subject to the 14, workers'compensation provisions of Section 3700 of the Labor Code,I shall ❑I, as owner of the roe ` forthwith comply with those provisions. property,rty, or my employees with wages as their sole ��,,}} 9 compensation,will do the work,and the structure is not intended or offered for k..l)ate"1^` A Signature C--- sale(Section 7044,Business and Professions Code:The Contractors License s� Law does not apply to an owner of property who builds or improves thereon, ti or who does such work himself or herself or through his or her own employees,provided that such improvements are not intended or offered for WARNING: Failure to secure Workers'Compensation coverage is unlawful, sale.If,however,the building or improvement is sold within one(1)year of _ and shall subject an employer to criminal penalties and civil fines up to one completion,the owner-builder will have the burden of proving that he or she hundred thousand dollars($100,000),in addition to the cost of compensation, did not build or improve for the purpose of sale). damages as provided for in Section 3706 of the Labor Code, interest, and attorney's fees. ❑I, as owner of the property, am exclusively contracting with licensed - contractors to construct the project(Section 7044,Business and Professions Code:The Contractors License Law does not apply to an owner of property CONSTRUCTION LENDING AGENCY who builds or improves thereon, and who contracts for such projects with a I hereby affirm under penalty of perjury that there is a construction lending agency contractor(s)licensed pursuant to the Contractors License Law). for the performance of the work for which this permit is issued (Section 3097, Civil Code). ❑ I am exempt under Section 7044,Business and Professions Code,for this reason: Lender's Name Date Signature Lender's Address IMPORTANT:APPLICATION IS HEREBY MADE TO THE BUILDING OFFICIAL FOR A PERMIT SUBJECT TO THE CONDITIONS AND RESTRICTIONS SET FORTH ON THIS APPLICATION AND THE FOLLOWING: 1. The City's approved plans and permit inspection card must remain on the job site for use by City inspection personnel. 2. Final inspection of the work authorized by this permit is required.A Certificate of Occupancy must be obtained prior to use and occupancy of new buildings and structures. 3. Per South Coast Air Quality Management District(AQMD)regulations,renovation and remodeling work that results in the removal,stripping,or altering of asbestos containing materials requires an asbestos survey and removal prior to disturbing the asbestos.Please contact AQMD at(909)396-2000 for further information. Name 0 r� r O v o/n Title "l V 7— el? {'' �jPRINT NAME 4,L 4 f.. h I §certify that I have read this application and state that the above information is correct and that I am the owner or duly authorized agent of the owner. 1 Tia ree to comply with all Cityordinances and State Laws relating to building construction. I hereby authorize representatives of the Cityof \.Arcadia to enter upon the above-mentioned property for inspection purposes. ' � 9.-1 � gid )(,� Signature r �� /✓ Date ( _1 LAGUNA• L 28202 Cabot Road, Suite 300 C CONSULTING.ENGINEERS Laguna Niguel, CA 92677 E 1'' LPG, INC. 949-371-5238 info@LagunaEngineers.com September 12,2019 -of ESS/04, rESKA To: Greenspire Construction 4 O. W ti 3130 Wilshire Blvd#200 5847 ' m Santa Monica,CA.90403 12/19 Tr Exp. Subject: Certification Letter Jj kr). Javellana Residence 4 R'CT13�''•� 1049 Oakdale Lane OF CA'y►j Arcadia,CA.91006Mir' \' Digitally signed by Paymon Eskandanian Date:2019.09.13 20:50:35-0T00' To Whom It May Concern, A jobsite observation of the condition of the existing framing system was performed by an audit team of Greenspire Construction as a request from Laguna Consulting Engineers.All review is based on these observations and the design criteria listed below and only deemed valid if provided information is true and accurate. On the above referenced project,the roof structural framing has been reviewed for additional loading due to the installation of the solar PV addition to the roof.The structural review only applies to the section of the roof that is directly supporting the solar PV system and its supporting elements.The observed roof framing is described below.If field conditions differ,contractor to notify engineer prior to starting construction. The roof structure of(Roof 1&2)consists of composition shingle roof,sloped at 15 degrees.The roofing material is supported by roof plywood and by the roof framing below. The existing roof framing system of(Roof 1&2)are judged to be adequate to withstand the loading imposed by the installation of the solar panels.No reinforcement is necessary. The spacing of the solar3tantioffssht uldbe'kept at 72"o.c.for landscape and'72"o<c for portrait orientation. • CITY OF,!RcADI The scope of this reportasstnctly ItiMitsinzifitiltjpciiMhritturverifitAchniqrvgderlying framing and supporting structure only. All panjjs,racking and hardware lAeoriut� er manufacturersPecifications and within specified design limitations.All waterprQRfing shall be providethey a 1u a r. Laguna ConsultinigEngineers assumes no responsibility for misuse or improper installaticIFI ;t sgiifIRIORPRIsp/i2EQIJngons must be kept "'• on the job at all times and no changes or alterations shall he trade e\ecpt by the Building Division. 14 Design Criteria: FThe Stamping of this plan and specification shall not -. • Applicable Go j C=atotlp cIsLc n E�7 tokan zNRs�; il'al of the violation • Roof Dead Load=""psftoo1 • Roof Live Load 4011;iiprovisions of any city ordinance or state law • Wind Speed=110 mph(Vult),Exposure C,Risk Category II • Attachments:1-5/16"dia.lag screw with 2.5 inch min embedment depth,at spacing shown above. Please contact me with any further questions or concerns regarding this project. Sincerely, Paymon Eskandanian,S.E. Principal Engineer Javellana Residence,Arcadia, CA 1 LAGUNA I 28202 Cabot Road,Suite 300 ,;s CONSULTING ENGINEERS Laguna Niguel, CA 92677 to, LPG, INC. 949-371-5238 info@LagunaEngineers.com Gravity Loading PV Dead Load=3 psf(PerGreenspire Construction) : DL Adjusted to 15 Degree Slope 3.11 psf N Ys em. eight Weight of PV System(Per Greenspire Construction) 3.0 psf X Standoff Spacing= 6.00 ft Y Standoff Spacing= 2.75 ft Standoff Tributary Area= 16.50 sft I Point Loads of Standoffs 50 lb Roof Live Load=20,psf Note:Roof live load is removed in area's covered by PV array. Roof Dead:Load'(Roof 1&2) Composition Shingle _ 4.00 Roof Plywood _ _ 2.00 Framing 0.73 Vaulted.Ceiling 0.00 (Ceiling Not Vaulted) Miscellaneous 0.27 Total Roof DL(Roof 1&2) 7.0 psf DL Adjusted to 15 Degree Slope 7.2 psf Javellana Residence,Arcadia, CA 2 L of LAGUNA 28202 Cabot Road, Suite 300 c CONSULTING ENGINEERS Laguna Niguel, CA 92677 949-371-5238 E l.'s LPG, INC. info@LagunaEngineers.com Wind Calculations Per ASCE 7-10 Components and Cladding ::?.:'etwzmoirciiittVarlablOfigitead Wind Speed 110 mph Exposure Category Roof Shape Gable/Hip Roof Slope 15 degrees Mean Roof Height 20 ft Effective Wind Area 19.3 ft tir„ elign Wind Pressure P=qh*G*Cn qh 0.00256*k'z*Xzt*Kd*VA2 (Eq 30.371) Kz(Exposure Coefficient)=0.9 (Table 30.3-1) Kzt(topographic factor)= 1 (Fig.26.8-1) Kd(Wind Directionality Factor)= 0.85 (Table 26.6-1) V(Design Wind Speed)=110 mph (Fig.26.5-1A) Risk Category= II (Table 1.5-1) qh= 23.70 0.6*qh= 14.22 tor770,4iteait Zone 1 Zone 2 Zone 3 Positive GCp= -0.84 -1.39 _ -2.23 0.38 (Fig.30.4-1) Uplift Pressure= -11.91 psf -19.76 psf -31.68 psf 10.0 psf (Minimum) X Standoff SPacing..= 6.00 6.00 4.00 Y Standoff Spacing= 2.75 2.75 2.75 Tributary Area= 16.50 16.50 11.00 Footing Uplift= -197 lb -326 lb -348 lb Pb t!MiA0210,6 Zone 1 Zone 2 Zone 3 Positive GCp= 0.84 -1.39 -2.23 0.38 (Fig.30A-1) Uplift Pressure= -11.91 psf -19.76 psf 41.68 psf 10.0 psf (Minimum) X Standoff Spading= 6.00 6.00 4.00 Y Standoff Spacing= 1.75 1.75 1.75 Tributary Area= 10.50 10.50 7.00 Footing Uplift= -125 lb -208 lb -222 lb tark0:11/..P I il....-.:69.ZZit's'ATIAMMai Maximum Design Uplift=-348 lb Standoff Uplift Capacity =450 lb 450 lb capacity>348 lb demand Therefore,OK MIC.WilitrAtAtME-010:KriCifiatit.g.,40.10taitAMAXge Fastener= 1-5/16"dia Lag Number of Fasteners= Embedment Depth=2.5 Pullout Capacity Per Inch=250 lb Fastener Capacity=625 lb w/F.S.of 1.5&DOL of 1.6=667 lb 667.2 lb capacity>348 lb demand Therefore,OK Javellana Residence,Arcadia, CA 3 S i ,, LAGUNA 28202 Cabot Road, Suite 300 11 CONSULTING ENGINEERS Laguna Niguel, CA 92677 is se, 949-371-5238 INC. 949-371-5238 info@LagunaEngineers.com Vertical Check Per CEBC Section 402.3 Qi Loading: (E)Existing (N)with PV D(psf, 7.0 psf 10.0 psf PV DL=3 psf Lr(psf) 20.0 psf 0.0 psf (Jnder Panels Only) S(psf) 0.0 psf 0.0 psf Total Roof Gravity Load 27.0 psf 10.0 psf %Change in Roof Gravity Load due to PV array addition %-DIFF=(N-E)/E =(10-27)/27 %-DIFF= 1-62.96% (O.K.) Per the California Existing Building Code(CEBC)2016 Section 402.3,indicates that alterations to a building that result in less than 5%increase in the gravity loads may be performed without a structural evaluation of the existing building.The member forces in the area of the propsed solar array will not increase by more than 5%.Therefore,the requirements of section 3403.3 have been met and the proposed addition of solar PV is allowed with no further remediation. Javellana Residence,Arcadia, CA 4 LAGUNA • L ,,� 28202 Cabot Road, Suite 300 c ,,' CONSULTING ENGINEERS Laguna Niguel, CA 92677 E ',i LPG, INC. 949-371-5238 info@LagunaEngineers.com Lateral Check Per CEBC 2016 Section 402.4 Existing Weight of Effected Building ;. Level Area Weight(psf) Weight(Ib) Roof 2250 sf 7.2 psf 16306 lb Ceiling 2250 sf 6.0 psf 13500 lb 7/8"Stucco 100 ft 11.0 psf 4400 lb (8'-0"Wall Height) Int.Walls 100 ft 6.4 psf 2560 lb Existing Weight of Effected Building 36766 lb I Proposed Weight of PV System Weight of PV System(Per Greenspire Construction) 3.0 psf Approx.Area of Proposed PV System 674 sf Approximate Total Weight of PV System 2022 lb 10%Comparison, 10%of Existing Building Weight(Allowed) 3677 lb Approximate Weight of PV System(Actual) 2022 lb Percent Increase 5.5% 3677 lb>20221b,Therefore OK j Javellana Residence,Arcadia, CA 5 N _.-z---Tz.- �-�- - r--. . -- =-z-z—�__ PV ARRAY F. .`."-`.".`.`.`.'-".`.`.`.`.`." " `.` '.`.`.`�".`:�.+� SOLAR MODULES w E '.`.`.`.' `. .".. .`.fir f _ -.`.`. .�� 35Hanwha285Watt t <a�s 35 ".......•."\-,, Model#Q.PLUS BFR-G4.1-285 `�`-`�'�•�`_' � `-` '�` ` INVERTER INVERTER TYPE:Central: R, - •+ . .- •` ` ` ` ` ' ' ' ` ' `- - -` ` ' ` ` ` ` ' - - � � - \� SolarEdge Technologies SE7600H-USRGM -- - p • • • • • p .. 67.-7 57-7° o . . .-. . (y<o~j) .I MSP (E)200A Main Service Panel D { ` IN (N)HD Wave 7.6 kW Inverter j / • . p ". I AC (N)60A AC Disconnect f( ( A > (/ . .4..t> °n • `_ - .- .-- ♦`+ - 4 -- D DRIVEWAYD I JB (N)Junction Box I C \ �f� / . . . . . . . . - .-.�. . . • — EMT type Conduit - ( - 3' _1'—- - - - - i —— — Fire Setback Line PV Array 2 iI 7 Q.PLUS BFR G4.1 285 C • . - . . .' 3'e— 0_, 1 2. 2 ` I Plr p , 7P320PowerOptimizers i `,`.`.".`-` 1 2 2 `_`_` ` `_` '_`I Tilt:15Deg r '.`.` sz.z^.`.3 1 1 1 1 e 1 2 2 .y.+.�.�.9�. - - I :' ais ' Azimuth:180 Deq - l I i 1 1 3'—f 1 2 2 1 •tl ��,x r . I n 1 2 2 . .-. .W-�.� o rt � - .................. .` ` " 'p. 1 2 2 - - - 1 m iv 7 h''ii„,fetf.1,:: ,„: .'..rt.',, pOFESS/ I `,• ' •-•. oOjg i ..`.+ •. ...TTT1 ae ,,,,,,.t,,,.,,,!:,.;,,:,'„4,3..,.,..,* a� S5847 P. I ' . . . 4 --J-lal - . . . . - - :,„747,,,,, it * EXP. 12/19 * ---.. `.`.'.'.`.'.` . . . ! .' '.`.`.`.'.`, I f�t ✓ CIN PV Array 1 !` :7.4."t "^. 28 Q.PLUS BFR G4.1 285 r p e•ti 9 28 P320 Power Optimizers ` fayu 1•t ...{� , Tilt:15 Deg IT?:x • STAMPEDING FOR Azimuth:90 Deq aj• w,1Y 1 ( EXISTING ROOF AND ATTCHMENT ONLY ''''''''"n"'"'"'"*"'""'. e. attaeo.. Pblat Sheol - ---- PHOTOVOLTAIC PV SYSTEM 114 neu�.:auewn.hir.owa ram Jose Javellana c�.reensplre�;oa4T.2 G LAYOUT Dat3eptember11,2019 pvi c CSLs•410t_n2e, PROPERTY PLAN 104s Oakdale Ln, NOTE:CONDUIT SHALL BE PAINTED TO MATCH EXISTING SURFACE. off' �°° ° °° „t„rr"Pt k,,.. -..• Arcadia,CA 91006 SW.AS INDICATED