Loading...
HomeMy WebLinkAboutSOLR-20-0854 City of Arcadia, CA b Permit nio SOLR r20-0854 w4ty-,4 Development Services Department i Permit Type Solar 240 West Huntington Drive,Post Office Box 60021F,M ,` ,• Arcadia,CA 91066-6021 �r� Piz' 'Work Classification:Solar 'Residential (626)574-5416 P..ermttStatus:Issued A ROAD IA Issue Date /22/ 20 0620Expiration: Expiration: 06/22/2021 -Addy NO. Dir Prefix Street Name Street Suffix Unit City,State,Zip Parcel Number • 1759 OAKWOOD AVE Arcadia, CA 91006-1722 5765022022 Contacts • BISHARA,NADER P AND Owner HPM SOLAR INC Contractor MAHROUS,VIOLA 1081 W 9TH ST, UPLAND,CA 91786 ' 1759 OAKWOOD AVE,Arcadia,CA 91006-1722 1048126 • NADERBISH@YAHOO.COM „; : Description:ROOF MOUNTED SOLARLSYSTEM 18 r Valuation: $ 0.00 t Tenant MODULES/MICRO INVERTERS-AND COMBINER. ' r ' , Total Sq Feet: 0.00 Plan Check#20-854 Plan# Fees Amount Payments Amount Paid Building Plan Check Fee Residential $50.00 Total Fees $324.72 Distribution Panel $16.48 Cash/Receipt#REC-04763-20 $324.72 Electrical Permit Issuance Fee $47.01 Fire Plan Check Fee Residential $50.00 Amount Due: $0.00 Inverters $77.78 Panels $82.45 Solid Waste Management Fee 2 $1.00 Total: $324.72 151 CQMPVIliDECTIONS� �.Z .?p�- Request for inspection by telephone at 626-574-5450. Leave a message requesting the address,timeframe and what inspection item is needed. • This permit/plan review expires by time limitation and becomes null and void if the work authorized by the permit is not commenced within 180 days from the date of issuance or if the permit is not obtained within 180 days from the date of plan submittal.This permit expires and becomes null and void if any work authorized by this permit is suspended or abandoned for 180 consecutive days or if no progressive work has been verified by a City of Arcadia building inspector for a period of 180 consecutive days. • • • • • • June 22, 2020 Issued By: Date • June 2.2,2020 • Page 1 of 1 4�uF""'1a9d �~ a• PERMIT/PLAN REVIEW. APPLICATION E. a j`F� Development Services Department,240 West Huntington Drive,Post Office Box 60021 4atta„Y°IK Arcadia, CA 91066-6021, (626)574-5416,Fax (626) 447-9173 City of Arcadia LICENSED CONTRACTOR'S DECLARATION WORKERS'COMPENSATION DECLARATION pI hereby affirm under penalty of perjury that I am licensed under provisions of I hereby affirm under penalty of perjury one of the following: Chapter 9(commencing with Section 7000,of Division 3 of the Business and Professions Code,and m 'cense is in full force and effect. ❑ I have and will maintain a certificate of consent to self-insure for workers' License Class 1 icense No. .26 Exp. Date 1A)1kIZS compensation, as provided for by Section 3700 of the Labor Code, for the •'Signature of Contractor ,. . 1a..�� performance of the work for which this permit is issued. -' � OWNER-BUILDER DECLARATIO 11 have and will maintain workers'compensation insurance,as required by Section El hereby affirm under penalty of perjury that I am exempt from the Contractors 3700 of the Labor Code,for the performance of the work for which this permit License Law for the following reason(Section 7031.5,Business and Professions is issued.My workers'compensation insurance carrier and policy numbers are: Code.Any city or county which requires a permit to construct,alter,improve, Carrier �` IVE W ntiT• S t&c S U,.t b demolish,or repair any structure,prior to its issuance,also required the applicant Policy Number 's—��.n for such permit to file a signed statement that he or she is licensed pursuant to the (This section need not be completed if the permit is for one hundred dollars or less) provisions of the Contractors License Law(Chapter 9(commencing with Section 7000)of Division 3 of the Business and Professions Code)or that he or she is exempt there from and the basis for the alleged exemption. Any violation of ❑ I certify that in the performance of the work for which this permit is issued,I shall Section 7031.5 by any applicant for a permit subjects the applicant to a civil not employ any person in any manner so as to become subject to the workers' penalty of not more than five hundred dollars($500)): compensation Laws of California,and agree that if I should become subject to the workers'compensation provisions of Section 3700 of the Labor Code,I shall ❑I, as owner of the property, or my employees with wages as their sole forthwith co ly with those provisio compensation,will do the work,and the structure is not intended or offered for sale(Section 7044,Business and Professions Code:The Contractors License Date�s? Signature Law does not apply to an owner of property who builds or improves thereon, or who does such work himself or herself or through his or her own employees,provided that such improvements are not intended or offered for WARNING: Failure to secure Workers'Compensation coverage is unlawful, sale.If,however,the building or improvement is sold within one(1)year of and shall subject an employer to criminal penalties and civil fines up to one completion,the owner-builder will have the burden of proving that he or she hundred thousand dollars($100,000),in addition to the cost of compensation, did not build or improve for the purpose of sale). damages as provided for in Section 3706.of.the Labor Code,interest, and attorney's fees. . ❑I, as owner of the property, am exclusively contracting with licensed - contractors to construct the project(Section 7044,Business and Professions Code:The Contractors License Law does not apply to an owner of property CONSTRUCTION LENDING AGENCY who builds or improves thereon,and who contracts for such projects with a I hereby affirm under penalty of perjury that there is a construction lending agency contractor(s)licensed pursuant to the Contractors License Law). for the performance of the work for which this permit is issued (Section 3097, Civil Code). ❑ I am exempt under Section 7044,Business and Professions Code,for this reason: Lender's Name Date Signature Lender's Address IMPORTANT: APPLICATION IS HEREBY MADE TO THE BUILDING OFFICIAL FOR A PERMIT SUBJECT TO THE CONDITIONS AND RESTRICTIONS SET FORTH ON THIS APPLICATION AND THE FOLLOWING: 1. The City's approved plans and permit inspection card must remain on the job site for use by City inspection personnel. 2. Final inspection of the work authorized by this permit is required.A Certificate of Occupancy must be obtained prior to use and occupancy of new buildings and structures. 3. Per South Coast Air Quality Management District(AQMD)regulations,renovation and remodeling work that results in the removal,stripping,or altering of asbestos containing materials requires an asbestos survey and removal prior to disturbing the asbestos.Please contact AQMD at(909)396-2000 for further information. � ^ — Name t cCi ALE 3-Z) Title CZA .A- a," -AP,b'c(2_ PRINT NAME I certify that I have read this application and state that the above information is correct and that I am the owner or duly authorized agent of the owner. I agree to corn 1 ly with all City ordinances and State Laws relating to building construction. I hereby authorize representatives of the City of 1C9(Zrcadia to enter . s on the above-mentioned property for inspection purposes. C) gnature J\%.`��-• ' ‘`t L.---�� Date \_------- • A B . C . D . E . F ol G . H GENERAL NOTES NEW PV SYSTEM: 6.660 kW SHEET LIST TABLE 1.1.1 PROJECT NOTES: pSHEET NUMBER SHEET TITLE 1 1.1.2 THIS PHOTOVOLTAIC(PV)SYSTEM SHALL COMPLY WITH THE CALIFORNIA ELECTRIC CODE(GEC)ARTICLE 690,ALL MANUFACTURERS'S LISTING AND T-001 COVER PAGEHPnl INSTALLATION INSTRUCTIONS,AND THE RELEVANT CODES AS SPECIFIED BY THE B I S H A RA RESIDENCE G4101 NOTES So 9 ai IIAUTHORITY HAVING JURISDICTION'S(AHJ)APPLICABLE CODES. >- s 1.1.3 THE IJELRY INTERCONCECTION APPLICATION MUST BE APPROVED AND PV A-101 SITE PLAN SYSTEM INSPECTED PRIOR TO PARALLEL OPERATION • (�n' 1.1.4 GROUND FAULT DETECTION AND INTERRUPTION(GFDI)DEVICE IS INTEGRATED 1759 OAI\Y Y OOD AVENUE A-102 ELECTRICAL PLAN WITH THE MICROINVERTER IN ACCORDANCE WITH CEC 690.41(B) A-103 SOLAR ATTACHMENT PLAN CONTRACTOR 1.1.5 ALL PV SYSTEM COMPONENTS;MODULES,UTILITY-INTERACTIVE INVERTERS,AND SOURCE CIRCUIT COMBINER BOXES ARE IDENTIFIED AND LISTED FOR USE IN E-001 UNE DIAGRAM HPM'+. - 2 PHOTOVOLTAIC SYSTEMS AS REQUIRED BY GEC 690.4: ARCADIA, CA 91006 E-002 DESIGN TABLES \\• PV MODULES:UL1703,IEC61730,AND IEC61215,AND NEPA 70 CLASS C FIRE COMBINER UL 1 RTIFIED,1703ORULE4IA,C9,S19O ASSESSOR'S#: 5765022022 E-603 PLACARDS PHONE: 909-303-0942 COMBINER BOX(ES):UL 1103 OR UL 1741 ACCESSORY ADDRESS:1001 W 9TH SIRE T 1.1.6 MAX DC VOLTAGE CALCULATED USING MANUFACTURER PROVIDED TEMPS-501 ASSEMBLY DETAILS UPLAND,CA917B6 COEFFICIENT FOR VOC. IF UNAVAILABLE, MAX DC VOLTAGE CALCULATED ACCORDING TO CEC 690.7. R-001 RESOURCE DOCUMENT ■ 1.1.7 ALL INVERTERS,PHOTOVOLTAIC MODULES,PHOTOVOLTAIC PANELS,AND SOURCE ■ LIE.NO.: 1048126 CIRCUIT COMBINERS INTENDED FOR USE IN A PHOTOVOLTAIC POWER SYSTEM R-002 RESOURCE DOCUMENT RIC.NO.: WILL BE IDENTIFIED AND LISTED FOR THE APPLICATION PER 690.4(D).SHALL BE ❑ ° ° ° R-003 RESOURCE DOCUMENT ELL NO.: INSTALLED ACCORDING TO ANY INSTRUCTIONS FROM LISTING OR LABELING ICE UNAUTHORIZED USE OF THIS WRH 110.31. ❑ R-004 RESOURCE DOCUMENT DRAWING SET OUTWWREN PERMISSION FROM CONTRACTOR IS IN 1.1.8 AU.SIGNAGE TO BE PLACED IN ACCORDANCE WITH LOCAL BUILDING CODE.IF ❑ ❑ °7.- R-005 RESOURCE DOCUMENT VIOLATION OF U.S.COPYRIGHT LAWS EXPOSED TO SUNLIGHT,IT SHALL BE W RESISTANT.ALL PLAQUES AND SIGNAGE ° AND WILL BE SUBJECT TO CNN. 30 DAMAGES AND PROSECUTIONS. WILL BE INSTALLED ASREOUIREDBYTHECECANDAHJ. ❑ 0 R-006 RESOURCE DOCUMENT ° NEW PV SYSTEM:6.660 kW 1.2.1 SCOPE OF WORK: 1.2.2 PRIME CONTRACTOR IS RESPONSIBLE FOR THE DESIGN AND SPECIFICATIONS OF - 0 BISHARA LJ A HA THE GRID-TIED PHOTOVOLTAIC SYSTEM RETROFIT.PRIME CONTRACTOR WILL BE D RESPONSIBLE FOR COLLECTING EXISTING ONSITE REQUIREMENTS TO DESIGN, ° ° SPECIFY,AND INSTALL THE ■ PHOTOVOLTAIC SYSTEMSOETAILEEDINTHISIOR DOCUMENTROOF-MOUNTED PORTION OF THE \ I ❑ ❑ .❑ ❑ • RESIDENCE 1.3.1 WORK RO ACPROJECT INFORMATION 1.3.2 ROOF ATTACHMENTS LUTDEHMENrs-UNIRACFLASHLOC 1759 OAKWOOD AVENUE 1.3.3 PV RACKING SYSTEM INSTAlLATION-UNIRAC STANDARD OWNER ARCADIA,CA 91006 1.3.4 PV MODULE AND INVERTER INSTALLATION-(18)RE REC370AA I(18)ENPHASE AERIAL PHOTO APN:5765022022 4 107PLUS-72.2-US 01 NAME: NADERBISHARA 1.3.5 PV EQUIPMENTGROUNDING NOT TO SCALE ENGINEER OF RECORD 1.3.6 PV SYSTEM WIRING TO A ROOF-MOUNTED JUNCTION BOX PROJECT MANAGER _ 1.3.7 PULOAD CFMERS(IF INCLUDED) � •M e�OFESS/p NSF NAME: ISAAC ALFARO 1.3.8 PV METERINGJIMONITORING(IF INCLUDED) 0 1 r� s PHONE: (909)3030942 1.3.9 PVDISCONCECTS 13.10 PV GROUNDING ELECTRODE BBONDING TO(E)GEC No.C58724 CONTRACTOR 1.3.11 PV FINAL COMMISSIONING ■ 1.3.12(E)ELECTRICAL EQUIPMENT RETROFIT FOR PV Exp.3-31-21 * ________ _____ NAME: HPM SOLAR I 1.3.13 SIGNAGE PLACED IN ACCORDANCE WITH LOCAL BUILDING CODE arf p J V 1� �P PHONE: (909)303-0942 SCOPE OF WORK 'p7, CA`10Q4 OF F I AUTHORITIES HAVING JURISDICTION SYSTEM SIE: STC:18x370W=6.660kW I PTC:18x351.8W=6.332kWDC BUILDING: CITYOFARCADIA (18)REC REC370AA May 29,2020 I di ¢ ZONING: CITYOFARCADIA 5 (18)ENPHASEIQ7PLUS•72.2-US www.Loyd W Martin.com o UTILITY: PAPER SIZE:II•N Ir(ANSI B) Solar Structures Engineering ATTACHMENT TYPE: UNIRAC FLASHLOC #2020-1124 Structural Only o DESIGN SPECIFICATIONS COVER PAGE ___________ OCCUPANCY: II MSP UPGRADE: NO CONSTRUCTION: SINGLE-FAMILY DATE: 0518102.0 ZONING: RESIDENTIAL ALL ELECTRICAL WORK SHALL BE DESIGNED PER ARCADIA MUNICIPAL CODE,2019 GROUND SNOW LOAD: 0 PSF 1 DESIGN BY:A.Y. ■ CALIFORNIA BUILDING CODE(2018 INTERNATIONAL BUILDING CODE),2019 CALIFORNIA ' - WIND EXPOSURE: B MECHANICAL CODE(2018 INTERNATIONAL MECHANICAL CODE),2019 CALIFORNIA WIND SPEED: 110 MPH CHECKED BY: M.M. PLUMBING CODE(2018 INTERNATIONAL PLUMBING CODE),2019 CALIFORNIA FIRE N REVISIONS 6 CODE(2018 INTERNATIONAL FIRE CODE)AND THE 2019 CALIFORNIA ELECTRICAL PLAT MAP APPLICABLE CODES&STANDARDS CODE(2017 NATIONAL ELECTRICAL CODE),2019 CALIFORNIA RESIDENTIAL CODE(2018 02W E BUILDING: CBC 2019,CRC 2019 INTERNATIONAL RESIDENTIAL CODE),2019 CALIFORNIA GREEN BUILDING STANDARDS NOT TO SCALE ELECTRICAL: NEC 2017,CEC 2019 1-001.00 CODE,2019 CALIFORNIA ENERGY CODE. S FIRE: CFC 2019 A . B • C • D • E . F • G . H (SHEET I) A . B i C . D . E . F . . G . H GENERAL NOTES 1. HELD VERIFY MEASUREMENTS 1iirk . 2. ITEMS BELOW MAY NOT BE ON THIS PAGE ----- PROPERTY LINE - ~, I-IPNI CAL-FIRE ROOF ACCESS POINT CONSTRUCTION NOTES CONTRACTOR PER CRC 2019 8324.6 TYP. 2 1. SOLAR PHOTOVOLTAIC SYSTEM TO BE INSTALLED 5,1 N • 10 COMBINER 80% 12-7" ON RESIDENTIAL STRUCTURE METERIMAIN 2. THIS PROJECT HAS BEEN DESIGNED IN PHONE: 909-303-0942 — — — — — --_ — — — — — — COMPLIANCE WITH THE CBC SECTION 1609 TO ADDRESS!1081 W 9TH STREET 1 WITHSTAND A BASIC WIND SPEED OF 110 MPH(3 UPLAND,CA 91286 ❑ ❑ SECOND GUST),WIND EXPOSURE B. ❑ ❑ 3. THE.ROOF MEMBERS ARE 2X4 TRUSS AT 24'ON CENTER.CONNECTION TO STRUCTURE SHALL NOT LIC.NO.: 1048126 — BE WITHIN 6'OF NAILING PLATES. TC.NO.: E ❑ W LE NO.: 4. THE SOLAR PHOTOVOLTAIC INSTALLATION SHALL UNAUTHORIZED USE OF THIS AREA OF WORK I ❑ ❑ ❑ I W NOT OBSTRUCT ANY PLUMBING,MECHANICAL OR DRAPEWING SET 1 CONTRACTOR'S IN ` BUILDING ROOF VENTS. ❑ VIOLATION OF U.S.COPYRIGHT LAWSDW 76 9" 0 3 I Q 5. ALL CONDUCTORS AND CONDUITS MOUNTED ON ANIMAL BE SUBJECT TOMS O • ROOF SHALL BE MINIMUM 3 314'ABOVE ROOF DAMAGES AND PROSECUTIONS. ❑ ❑ SURFACE (INCLUDING CABLES UNDERNEATH ❑ NEW PV SYSTEM:6.660 kW MODULES AND RACKING). ENTRANCE 6. ROOF ACCESS POINTS SHALL BE PROVIDED PER ❑ 77-1" O THE FOLLOWING(CRC R324.6,CBC 311121): BISHARA ( . 0❑ - o° LADDERSAREAS NOT PLACEMENT RESIDENCE DOORS OR WINDOWS \ 0 0 0 0 1759 OAKWOOD AVENUE LOCATED ATO SIN NG POINTSOF BUILDING ARCADIA,CA 91006 • CONSTRUCTION IN LOCATIONS WHERE ACCESS POINT DOES NOT CONFLICT WITH OVERHEAD • APN:5765022022 4 — — — — — — — — — — — — OBSTRUCTIONS SUCH AS:TREE LIMBS,WIRES,OR SIGNS ENGINEER OF RECORD 25'-11" CAL-FIRE ROOF ACCESS POINT PER CRC 2019 8324.6 TYP. N C?Es ■ ••C58724I . .3.31.21 * PAPER SZE 11'[1T(ANSIB) 5 IVcM.\*& SITE PLAN , May 29,2020 www.Loyd W Martin.com DATE: 05.28.2020 Solar Structures Engineering DESIGN BY:AN: 1 #2020-1124 Structural Only CHECKED BY: M.M 6 SITE PLAN N REVISIONS B W E 0 31�'=''A' A-101.00 A • B • C • D' " - E - F • G - H (SHEET3) Loyd W. Martin Professional Engineer, Inc. 9924 Universal Boulevard #224-406 Orlando, FL 32819 Te1:1 .310.464.1804 Email: Ioydwmartin@gmail.com www.loydwmartin.com Structural Calculations for a Roof Mounted Solar Photovoltaic System for: Bishara Residence 'le 1759 Oakwood Ave., .�, _ M Arcadia, CA 91006, ''_� � W No. C58724 Applicable Codes: * Exp.3-31-21 9T ��� 2019 California Building Code, 2019 California Electric Code, F°F cAI.�F 2019 California Mechanical Code, American Society of Civil Engineers Standard ASCE 7-16 Minimum Design Loads for Buildings and Other Structures, American Wood Council 2018 National Design Specification for Wood Construction, Local Municipal Code, and all other codes which are adopted by reference or enacted by law. Assumed Design Parameters: The existing structure has been built under a building permit and is in its original condition. The existing roof structure is capable of its code required live load and the ability of the roof structure to support live loads has not been substantially reduced by the age of the structure, termites or mold, or unauthorized modifications to the existing structure. Solar Energy Contractor shall make an inspection of the existing roof framing system prior to installation of the roof mounted solar energy system to verify that the existing roof is capable of supporting minimum roof live loads. Assumed Design Parameters: All 2x members are grade Douglas Fir #2 or better All 4X members are grade Douglas Fir #1 or better All Roof Connectors are Simpson Strong-Tie or Equal All ConcreteFoundations are fc = 2500 psi or stronger Original Structure was built to the Type-V Wood Framed Standards of the Applicable Building Code at the time of Construction. Sht# 1 of 7 2020-1124 HPM Solar Bishara Residence Date: May 29, 2020 Loyd W. Martin Professional Engineer, Inc. 9924 Universal Boulevard #224-406 Orlando, FL 32819 Te1:1 .310.464.1804 Email: loydwmartin@gmail.com www.loydwmartin.com Note to Building Official: Based upon a review of the proposed plans and information, the existing roof framing system is capable of safely supporting the additional loads caused by the new solar photovoltaic energy system. The contractor shall field verify that the existing roof structure is in its original permited condition and verify that it can support the normal code required roof live loads. Attached in this package are several calculations showing that the roof members can support the additional weight of the solar array. Furthermore, an analysis of the solar array's support for wind forces and a seismic analysis of the existing structure are also included. .�oQROF ESS70 - \N. M, Check Existing 2x4 Roof Trusses @ 24" O.C.: * ' z No. C58724 * Exp.3-31-21 d!`,/rIP 'e OF W DL+LL W DL+LL = 32.7 psf x 2 ft. = 65.4 plf L _ W DL = 12.7 psf x 2 ft. = 25.4 plf R1 21, R2 1 Total load on truss = 65.4 plf x 21 ft. = 1,373 lbs *Note: Contractor to Field Verify Framing Sht # 2 of 7 2020- 1124 HPM Solar Bishara Residence Date: May 29, 2020 • Loyd W. Martin Professional Engineer, Inc. 9924 Universal Boulevard #224-406 Orlando, FL 32819 Te1:1 .310.464.1804 Email:, loydwmartin@gmail.com www.loydwmartin.com Check Existing 2x4 Roof Trusses Ccs 24" O.C.: P P PP W 7 D 7 7 7 LL 111111 W DL /////////////////////////////// WDL+LL = 32.7psf x2ft. = 65.4plf L w DL = 12.7 psf x 2 ft. = 25.4 plf R1 R2 21' 2' 16.5' 2.5' Total load on truss = 65.4 plf x'4.5 ft + 25.4 plf x 16.5 ft + ( 4' x 2.75' x 3 psf x 6 ) = 911 lbs < 1,373 lbs OK Check attachment of Support to Existing Structure for Wind Uplift CHECK SOLAR STRUCTURE ATTACHMENTS PER ASCE 7- 16WIND LOADS ON BUILDING APPURTENANCES AND OTHER STRUCTURES Section 29.4.4 THEREFORE CHECK ATTACHMENT FOR TYPICAL CRITICAL LOAD WHICH IS THE EDGE ZONE - ZONE 2. NOTE: PER DEFINITION ON SHEETS 246 & 247 OF ASCE 7- 16 EFFECTIVE WIND AREA: "FOR ROOFTOP SOLAR ARRAYS, THE EFFECTIVE WIND AREA IN FIG. 29.4-7 IS EQUAL TO THE TRIBUTARY AREA FOR THE STRUCTURAL ELEMENT BEING CONSIDERED, EXCEPT THAT THE WIDTH OF THE EFFECTIVE WIND AREA NEED NOT BE LESS THAN ONE-THIRD ITS LENGTH." .�oQ�OF ESS704 44,:t EFFECTIVE AREA = 15 SQ FTo •'' y No. C58724 * Exp.3-31-21 s�, C1V1� 9TF OF C Pk1.0-- Sht# 3of7 2020- 1124 HPM Solar Bishara Residence Date: May 29, 2020 Loyd W. Martin Professional Engineer, Inc. 9924 Universal Boulevard #224-406 Orlando, FL 32819 Te1:1 .310.464.1804 Email: Ioydwmartin@gmail.com www.loydwmartin.com Check attachment of Support to Existing Structure for Wind Uplift - Cont'd Tributary Area to Each Solar Mount = 4 ft. x 2.75 ft. = 11 sq. ft. ( Max ) Calculate Design Wind Pressure at each support (Wind Speed 130 mph Exposure C): P=qh(GCp)(7E)(7a) Eq'n 29.4-7 ASCE 7- 16 qh= 0.00256 KzKztKdKe V` Eq'n 26.10- 1 ASCE 7- 16 Note: KZ = velocity pressure coefficient Section 29.10.1 ASCE 7- 16 Kz = 0.9 (Exposure C, Height = 20 ft or less) Kzt= Topographical Factor = 1.0 Kd = Wind Directionality Factor = 0.85 Ke = Ground Elevation Factor = 1.0 V = 130 mph ; VASB= 101 mph Table 1609.3.1 2019 CBC _okofEss�I qh= 0.00256 (0.9) (1.0) (0.85) (1.0) (101)2 No. C58724 qh= 20 psf * Exp.3-31-21 * GCp = -2.0 (Zone 2 ; Effective Area = 15 sq. ft. ) 9rF c ioF A�F(�4s- YE = Exposure Factor = 1.5 7a = Solar Array Pressure Equalization Factor = 0.7 Fig. 29.4-8 ASCE 7-16 P=qh(GCp)(7E)(7a) p = 20 psf (-2.0) (1 .5) (0.7) = 42 psf Nominal (Unfactored) Uplift at each support = 42 psf x 11 sq. ft. = 462 lbs Note: Section 2.4.1 of ASCE 7- 16, Basic Load Combinations for Allowable Stress Design. Note: Applicable Load Combination #5 (D + 0.6W) Design (Factored) Uplift at each support = 0.6 x 462 lbs = 277 lbs Load per lag screw = 277 lbs 11 = 277 lbs Sht # 4 of 7 2020- 1124 HPM Solar Bishara Residence Date: May 29, 2020 Loyd W. Martin Professional Engineer, Inc. 9924 Universal Boulevard #224-406 Orlando, FL 32819 Te1:1 .310.464.1804 Email: loydwmartin@gmail.com www.loydwmartin.com Check attachment of Support to Existing Structure for Wind Uplift - Cont'd Determine allowable load per 5/16" lag screw w/ 2.5" embedment into wood below according to the 2018 NDS. W ' = WxCdxCt Table 10.3.1 2018 NDS where: W = 266 lbs / in. of embedment per Table 12.2a Cd =1.6 per Table 2.3.2 of 2018 NDS Ct = 1.0 per Table 10.3.4 of 2018 NDS W ' = 266 lbs/ in. x 2.5 in. x 1.6 x 1.0 = 1,064 lbs > 277 lbs OK Use Support connected to 2x Min. Roof Member w/ (1) 5/16" x 3.5" lag screws per connection minimum. ,w)F ESS/0N • 0 No. C58724 Exp.3-31-21 OIVIV . 9 lFOF cA061- Sht # 5of7 2020- 1124 HPM Solar Bishara Residence Date: May 29, 2020 Loyd W. Martin Professional Engineer; Inc. 9924 Universal Boulevard #224-406 Orlando, FL 32819 Te1:1 .310.464.1804 Email: loydwmartin@gmail.com. www.loydwmartin.com Check Seismic load due to added dead load of photovoltaic system. Determine Seismic Weight of Existing Building: Effective Existing Seismic Weight Area of (E) Building = Approximately 1,800 Sq. ft. Approximate Effective = 1,800 sq. ft. x 30 psf ave. = 54,000 LBS Seismic Weight DETERMINE BASE SHEAR .<oQ(toFEss/pNgl co o V = Cs W EQ'N 12.8-1 ASCE 7- 16 g No. C58724 * Exp.3-31-21 Cs = SDS f-EQ'N 12.8-2 ASCE 7- 16 1976. civ R 0F C Al\F ] le R = THE RESPONSE MODIFICATION FACTOR IN TABLE 12.2-1 R = 6.5 WOOD SHEAR WALLS le = 1.0 IMPORTANCE FACTOR SPS = 2/3 x SMs EQ'N 11.4-3 ASCE 7- 16 Skis= FA x SS EQ'N 11.4- 1 ASCE 7- 16 SMS= 1.0x1.5 = 1.5 Sps = 2/3 x 1.5 = 1.0 1.0 EQ'N 12.8-2 ASCE 7- 16 Cs = 1-6.51 = 0.154 1 Sht# 6 of 7 2020- 1124 HPM Solar Bishara Residence Date: May 29, 2020 Loyd W. Martin Professional Engineer, Inc. 9924 Universal Boulevard #224-406 Orlando, FL 32819 Te1:1 .310.464.1804 Email: loydwmartin@gmail.com www.loydwmartin.com EXISTING BASE SHEAR V = 0.154 x 54,000 LBS = 8,316 LBS EQ'N 12.8- 1 ASCE 7- 16 DETERMINE NEW BASE SHEAR Determine Seismic Weight of Building with Solar Array: EXISTING 10.:0FE SO4/ SEISMIC = 54,000 LBSo WEIGHT - No. C58724 NEW SOLAR * Exp.3-31-21 * ARRAY = 3 PSF x 18 PANELS x 3.3' x 5.5' = 980 LBS `P�9TF civip c cO°��\P NEW SEISMIC = 54,000 LBS + 980 LBS = 54,980 LBS WEIGHT THEREFORE NEW BASE SHEAR: V = 0.154 x 54,980 = 8,467 LBS EQ'N 12.8- 1 ASCE 7- 16 % CHANGE = 8,467 LBS - 8,316 LBS• x 100 = 1.8 % < 10% OK 8,316 LBS OK. PER ASCE 7-16 SECTION 11.B.3 ALTERATIONS EXISTING LATERAL FORCE RESISTING SYSTEM IS EXEMPT FROM ANALYSIS SINCE NEW SEISMIC FORCE IS LESS THAN 10% GREATER THAN EXISTING SEISMIC FORCE. "Alterations are permitted to be made to any structure without requiring the existing structure to comply with this standard provided the alterations comply with the requirements for a new structure.Alterations that increase the seismic force in any existing structural element by more than 10 percent or decrease the design strength of any existing structural element to resist seismic forces by more than 10 percent shall not,be permitted unless the entire seismic force-resisting system is determined to comply with this standard for a new structure." End of Calculations Sht # 7of7 2020- 1124 HPM Solar Bishara Residence Date: May 29, 2020 Loyd W. Martin Professional Engineer, Inc. 9924 Universal Boulevard #224-406 Orlando, FL 32819 TeI:1 .310.464.1804 Email: loydwmartin@gmail.com www.loydwmartin.com Determine Loading on Roof Trusses Dead and Live Loads without Panels: Comp. Shingle Roofing = 4.0 psf (900 ESS/04,4e 1/2 Sheathing _ 1.5 psf oe �Fm 2x4 Trusses @ 24" O.C. 2.5 psf No. C58724 5/8" Drywall = 3.1 psf * Exp.3-31-21 Misc. / Insul = 1.0 psf civic �� 9rFpF CA1.O` Dead Load = 12.1 psf w/ DL Corr. (1.05) = 12.7 psf Live Load = 20.0 psf Total Load = - 32.7 psf Dead Loads with Panels: Comp. Shingle Roofing = 4.0 psf 1/2 Sheathing = 1.5 psf 2x4 Trusses @ 24" O.C. = 2.5 psf 5/8" Drywall = 3.1 psf Misc. / Insul = 1.0 psf Dead Load = 12.1 psf w/ DL Corr. (1.05) _ 12.7 psf Total Load = 12.7 psf Solar Array = 3.0 psf (Note: Solar Loads are point loads on members) Total Load with Solar Array = 15.7 psf < 32.7 psf OK Sht#R1 2020- 112.4 HPM Solar Bishara Residence Date: May 29, 2020