Loading...
HomeMy WebLinkAboutSOLR-19-2411 City of Arcadia, CA Permit NO S0141-19-2411 : -�, Development Services Department ! Tl 'v ry `Permit Type:Solar 911;., 240 West Huntington Drive,Post Office Box 60021 ;� iI ( '_.f.:, WorkCfassifcation Solar Residential y � Arcadia,CA 91066-6021 ��,� F (626)574-5416 P,ermit Status Issued ry ARCADIA r • Issue Date 12/02/2o19I Expiration: Addr NO. Dir Prefix Street Name Street Suffix Unit City,State,Zip Parcel Number 9 E LAS FLORES AVE Arcadia,CA 91006-4633 5789014013 Contacts LARRY H AND ELIZA L CHOW Owner SOUTH WEST DEVELOPMENT INC* Contractor '9 E LAS FLORES AVE,ARCADIA CA,91006 12517 SHERMAN WAY B,NORTH HOLLYWOOD,CA 91607 (323)301-0672 1031232 SOUTH WEST DEVELOPMENT INC* Contractor 12517 SHERMAN WAY B,NORTH HOLLYWOOD,CA 91607 (323)301-0672 63328 � `,•4a'a Description:ROOF MOUNTED SOLAR SYSTEM 12 MODULES, 1 1 Valuation: $ 0.00 Tenant INVERTER Total Sq Feet: 0.00 Plan Check# Plan# �:,�5]G" J.`_.,.T e`_J.k•ihQP$..AS'Mk.:k.., .x. .M_�-...mss-. ...__._ ..a l�S.�=a3.P.�:C�+€.....:� Fees Amount payments Amount Paid Building Plan Check Fee Residential $50.00 Total Fees $308.24 Electrical Permit Issuance Fee $47.01 Cash/Receipt#REC-03228-19 $308.24 Fire Plan Check Fee Residential $50.00 Inverters $77.78 Amount Due: $0.00 Panels $82.45 Solid Waste Management Fee 2 $1.00 Total: $308.24 Ea TED Ell CALLS FOR INSPECTIONS / �j�/ Request for inspection by telephone at 626-574-5450. Leave a message l/0� requesting the address,timeframe and what inspection item is needed. This permit/plan review expires by time limitation and becomes null and void if the work authorized by the permit is not commenced within 180 days from the date of issuance or if the permit is not obtained within 180 days from the date of plan submittal.This permit expires and becomes null and void if any work authorized by this permit is suspended or abandoned for 180 consecutive days or if no progressive work has been verified by a City of Arcadia building inspector for a period of 180 consecutive days. • Ve/2 December 02, 2019 Issued By: Date December 02,2019 Page 1 of 1 CA~��FFoitiN C•i I_ PERMIT/PLAN REVIEW APPLICATION ..,, ,, Development Services Department,240 West Huntington Drive,Post Office Box 60021 ti \Y% Arcadia, CA 91066-6021, (626) 574-5416,Fax (626) 447-9173 City of Arcadia LICENSED CONTRACTOR'S DECLARATION WORKERS'COMPENSATION DECLARATION 0 I hereby affirm under penalty of perjury that I am licensed under provisions of I hereby affirm under penalty of perjury one of the following: Chapter 9(commencing with Section 7000,of Division 3 of the Business and Professions Code,and my license is in full force and effect. ❑ I have and will maintain a certificate of consent to self-insure for workers' License Class c_10 lB License No. )D312'3" . Exp. Date compensation, as provided for by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. Signature of Contractor OWNER-BUILDER DECLARATI ❑ I have and will maintain workers'compensation insurance,as required by Section 0 I hereby affirm under penalty of perjury that I am exempt from the Contractors 3700 of the Labor Code,for the performance of the work for which this permit License Law for the following reason(Section 7031.5,Business and Professions is issued.My workers'compensation insurance carrier and policy numbers are: Code.Any city or county which requires a permit to construct,alter,improve, Carrier demolish,or repair any structure,prior to its issuance,also required the applicant for such permit to file a signed statement that he or she is licensed pursuant to the Policy Number provisions of the Contractors License Law(Chapter 9(commencing with Section (This section need not be completed if the permit is for one hundred dollars or less) 7000)of Division 3 of the Business and Professions Code)or that he or she is exempt there from and the basis for the alleged exemption. Any violation of I certify that in the performance of the work for which this permit is issued,I shall Section 7031.5 by any applicant for a permit subjects the applicant to a civil not employ any person in any manner so as to become subject to the workers' penalty of not more than five hundred dollars($500)): compensation Laws of California,and agree that if I should become subject to the workers'compensation provisions of Section 3700 of the Labor Code,I shall ❑I, as owner of the property, or my employees with wages as their sole forthwith comply with those provisions. compensation,will do the work,and the structure is not intended or offered for4 Date l� IZ ' l� Signature .r77:-----i sale(Section 7044,Business and Professions Code:The Contractors License Law does not apply to an owner of property who builds or improves thereon, 1 or who does such work himself or herself or through his or her own 1` employees,provided that such improvements are not intended or offered for WARNING: Failure to secure Workers'Comp-'= .1•+ average is unlawful, sale.If,however,the building or improvement is sold within one(1)year of and shall subject an employer to criminal penalties and civil fines up to one completion,the owner-builder will have the burden of proving that he or she hundred thousand dollars($100,000),in addition to the cost of compensation, did not build or improve for the purpose of sale). damages as provided for in Section 3706 of the Labor Code, interest, and attorney's fees. 0 I, as owner of the property, am exclusively contracting with licensed contractors to construct the project(Section 7044,Business and Professions Code:The Contractors License Law does not apply to an owner of property CONSTRUCTION LENDING AGENCY who builds or improves thereon,and who contracts for such projects with a I hereby affirm under penalty of perjury that there is a construction lending agency contractor(s)licensed pursuant to the Contractors License Law). for the performance of the work for which this permit is issued (Section 3097, Civil Code). 0 I am exempt under Section 7044,Business and Professions Code,for this reason: Lender's Name Date Signature Lender's Address IMPORTANT: APPLICATION IS HEREBY MADE TO '1'HL+ BUILDING OFFICIAL FOR A PERMIT SUBJECT TO THE CONDITIONS AND RESTRICTIONS SET FORTH ON THIS APPLICATION AND THE FOLLOWING: 1. The City's approved plans and permit inspection card must remain on the job site for use by City inspection personnel. 2. Final inspection of the work authorized by this permit is required.A Certificate of Occupancy must be obtained prior to use and occupancy of new buildings and structures. 3. Per South Coast Air Quality Management District(AQMD)regulations,renovation and remodeling work that results in the removal,stripping,or altering of asbestos containing materials requires an asbestos survey and removal prior to disturbing the asbestos.Please contact AQMD at(909) 396-2000 for further information. ` 1 Name m 1 _4I 1 %V\ Title 1:, T 4 PRINT NA I certify that I have read this application and state that the above information is c i rrect and that I am the owner or duly authorized agent of the owner. I agree to comply with all City ordinances and State Laws relating to buildi 1g construction. I hereby authorize representatives of the City of Arcadia to enter upon the above-mentioned property for inspection purposes. Signature V (Date 11—' //c N sFDO a / (E) MSP LADDER ACCESS 2 LADDER ACCESS 1 DRIv WAY 1\e) PL 100' _ Q FTORS Q % ti . . • �'jr • . wrsat . . ... .. . i. .. --------- ---- ..- • ----. :: ,1,-.,Q.0ert.y:A00,-....„.,.„.... ,. ..,...._:, .,.....:_ :::: ::,,s.,..:::J........, :: :..e..,•..-::. ,-. ..,. c 4 l •.,... ..,.:,,.......:::„,......................:H:„., ...,,,.,:,:,:.,:„., _„„:,.,:.„:,:.;:::::::.............,":,.........H:::. .::.." :, ..-::: : _:.::. . .. .. ... ::::-..„..,:::::.:::::::::::::,...,.,.:.:::!..:..,..,:„...,:,,„„::::„:.,.,:..::....„,„:„:..............„....,...,,,:::::.. .,„....S__ iuI iof sohea as atafled .•- • .wm fti r r nri p . rite t o • er , l era on W ,.: pt i additions i n :permit:occur, sleeping rooms.ire created; rote l rry shalt e installed °0each steeping r o nx and t ioe each ear . .....................................................the r o m ,;and n e .t €tronas t pt:t.40..: r wlft410144_rra emit 04.0 rarert * tr4 t _ :; lifo is. r tiet code (CRC) nn . t r tia ; a t and Safety Code-Section 31:1 ' For ling;or & ep1n .u t . n1a n n ft a t r-nin c t rrc.e r -i a_tr .a ra ,•cit on an i e: alarms °n l :: jrnst It c tsr each b• €ate tse ii :: ,:ares .#n. ttn i rrae iat € rn og t ie ro a ci each additional st 61.; f th `: . :ll€r gx .tn lu r aseme is. ; ul e i byorlon ¢ of he' f t$n 201 C z orhr . tint€ l' Code ( ) . r iti ut pose ai rr s..( ombi at n: r monoxide and smote t rrs may a to e . ll ala rr1 shale c al f wi r it m s r°l tin and ro a t Once at;the State Fre . • - r aI tt llu tr;} 'f ire r g rrtt 41,, r., elp 1 Q,WI spa€ r t:tIrwi- o .4 of the above r fer; n .: ron y.; I h r; rti y that t e' smote t rm _and ,arbor z1`or�oxtde..al r i hay : been r tazl.= .in" coi ar•ce i i ; anuf a' t fog €" trot€on nd' in t o �t n .r malt o r o t° of g ls. t .-- r t;• ithat t tiek i w.w c • •t t � : (.0 ....,:,,,...1'1,:4.!'44,4.'.i .. r.✓1: t err e di , Caith t `n¢ •. J ,..• ...• . . : .......:•......• ...•::....::: :.:::.•. : ,..„..•,.• .... k,rigs tame (p i r t It ,i,d ,.L ,:“,. „,•••...-...,,,..„„.„,,:,,,„,. i:-.• . g� i. •.„„• : • .,•••: . . ,„-- . •• H.--• • . .ifittlei.1-, ., �r, p� ...rt c,. CF i*,}t:d,.+'��+x,$ $ s�.�.� re'r�rr`n0�to t�$�a: i tyo�-�€ Ga ,'a .i'fls.sA i✓ oo-r..t{i`Artft 1!4 .x04aio `', , : ti 11/25/2019 r vf„►t00 your IP tans. ;oat 1 e. ENGINEERING SOLUTIONS FOR ALL YOUR SOLAR NEEDS Structural Calculations for SOLAR POWER SYSTEM CONNECTION CHECK AT: 9'E 'Flores Ave. Arcadia,CA 91006 Job: Chow,Larry Prepared For: Southwest Solar 13407 Saticoy St. North Hollywood,CA 91605 (855)808-8887 Design Criteria - 1- Code: CALIFORNIA BLDG CODE 2016/ASCE 7-10 2-Wind: 110 MPH,Exposure:C 3 -Wood Species:DF-L No.2(SG= 0.5) Notice:Use restrictions of these calculations. The attached Calculations are valid only when bearing original signature hereon. Contractor/Client to verify existing dimensions/conditions prior to construction &solar racking is installed per manufacturer span requirements. The use of these calculations is solely intended for the above mentioned project. � QROFESS/ON94 Er No. C70784 73 * Exp.0613012021 • lE OF CA1=t..1 1-844-PV ELITE I info@yoursolarplans.com 3000 E.Birch Street Suite 2011 Brea CA 92821 WIND LOADING ANALYSIS - Roof Components and Cladding Per ASCE 7-10 Code for Bldgs.of Any Height with Gable Roof 0 <=45°or Monoslope Roof 0 <=3° Using Part 1 &3: Analytical Procedure (Section 30.4&30.6) Job Name: Chow, Larry Subject: Job Number: Originator: I Checker: I Input Data: Wind Speed,V= 110 . mph (Wind Map, Figure 26.5-1A-C) 3ldg. Classification = II ' ' (Table 1-1 Occupancy Category) Exposure Category= C (Sect. 26.7) B Ridge Height, hr= ' 22.35 ft. (hr>= he) Eave Height, he=.. 17:00'` ft. (he<= hr) Building Width= 35.00"" 'ft. (Normal to Building Ridge) Building Length = 85:00 ft. (Parallel to Building Ridge) I L Roof Type= Gable.. (Gable or Monoslope) I� Plan >I Topo. Factor, Kzt= .1.00 (Sect.26.8& Figure 26.8-1) Direct. Factor, Kd = 0.85 (Table 26.6) Enclosed? (Y/N) . Y:` (Sect.28.6-1 &Figure 26.11-1) Hurricane Region? N 0 Component Name= Fastener (Purlin, Joist, Decking, or Fastener) hr Effective Area,Ae= - 268' ft.^2 (Area Tributary to C&C) he Overhangs? (Y/N) N (if used, overhangs on all sides) L Resulting Parameters and Coefficients: Elevation Roof Angle, 0= 17.00 'deg. Mean Roof Ht., h= 25.00 ft. (h= (hr+he)/2,for roof angle>10 deg.) Roof External Pressure Coefficients, GCp: 3Cp Zone 1-3 Pos. = 0.30 (Fig. 30.4-2A, 30.4-2B, and 30.4-2C) GCp Zone 1 Neg. = -0.80 (Fig. 30.4-2A, 30.4-2B, and 30.4-2C) GCp Zone 2 Neg. = -1.20 (Fig. 30.4-2A, 30.4-2B, and 30.4-2C) GCp Zone 3 Neg. = -2.00 (Fig. 30.4-2A, 30.4-2B, and 30.4-2C) Positive&Negative Internal'Pressure Coefficients, GCpi (Figure 26.11-1): +GCpi Coef. = 0.18 (positive internal pressure) -GCpi Coef. = -0.18 (negative internal pressure) If z<= 15 then: Kz=2.01*(15/zg)^(2/a) , If z> 15 then: Kz=2.01*(z/zg)^(2/a) (Table 30.3-1) a= 9.50 (Table 26.9-1) zg = 900 (Table 26.9-1) Kh = 0.95 (Kh =Kz evaluated at z= h) Velocity Pressure: qz=0.00256*Kz*Kzt*Kd*V^2 (Sect. 30.3.2, Eq. 30.3-1) qh = 24.89 psf qh =0.00256*Kh*Kzt*Kd*V^2 (qz evaluated at z= h) Design Net External Wind Pressures(Sect. 30.4&30.6): For h <=60 ft.: p=qh*((GCp)-(+/-GCpi)) (psf) For h > 60 ft.: p=q*(GCp)-qi*(+/-GCpi) (psf) where: q=qh for roof qi =qh for roof(conservatively assumed per Sect. 30.6) Wind Load Tabulation for Roof Components&Cladding Component z Kh qh p= Net Design Pressures (psf) (ft.) (psf) ?one 1,2,3(+ Zone 1 (-) Zone 2 (-) Zone 3 (-) Fastener 0 0.95 24.89 11.95 -24.39 -34.35 -54.26 15.00 0.95 24.89 11.95 -24.39 -34.35 -54.26 20.00 0.95 24.89 11.95 -24.39 -34.35 -54.26 For z= hr: 22.35 0.95 24.89 11.95 -24.39 -34.35 -54.26 For z= he: 17.00 0.95 24.89 11.95 -24.39 34.35 ` -54.26 For z= h: 25.00 0.95 24.89 11.95 -24.39 -34.35 ' -54.26 Notes: 1. (+)and (-)signs signify wind pressures acting toward &away from respective surfaces. 2.Width of Zone 2 (edge), 'a'= 3.50 ft. 3.Width of Zone 3 (corner), 'a'= 3.50 ft. 4. For monoslope roofs with 0<= 3 degrees, use Fig. 30.4-2A for'GCp'values with 'qh'. 5. For buildings with h> 60'and 0 > 10 degrees, use Fig. 30.6-1 for'GCpi'values with 'qh'. 6. For all buildings with overhangs, use Fig. 30.4-2B for'GCp'values per Sect. 30.10. 7. If a parapet>= 3' in height is provided around perimeter of roof with 0 <= 10 degrees, Zone 3 shall be treated as Zone 2. 8. Per Code Section 30.2.2, the minimum wind load for C&C shall not be less than 16 psf. 9. Reference: a.ASCE 7-10, "Minimum Design Loads for Buildings and Other Structures". b. "Guide to the Use of the Wind Load Provisions of ASCE 7-10" by: Kishor C. Mehta and James M. Delahay(2004). Roof Components and Cladding: u Jt 1 i t I I 1 r t Y t II 1 l t i 1 I I I t I 1 1 1 1 a )5 kap ., o Q _ C5 11C1 Z5-Fj 0<=7 deg. 7 deg. <0<=27 deg. 27 deg. <0 <=45 deg. Roof Zones for Buildings with h <=60 ft. (for Gable Roofs<=45°and Monoslope Roofs<=3°) hkic r r _ �Y a • o • r I , CD", ROOF PLAN Roof Zones for Buildings with h > 60 ft. (for Gable Roofs<= 10°and Monoslope Roofs<=3°) Gravity Load Data Panel Data Panel: LG-400N2A5 Number of Modules: ; 12 ....... ........ ...... Weight of PV Module 47:74lbs PV Module Dimensions L= -79.69 in W= 40.31,:in Roof Data Roof Material: Tile Roof Dead Load QD= 1,6;psf PV System Dead Load Qpv= 3 psf Framing Spacing / sroof= 24 in Linear Dead Load WD=(QD+Qpv)*sroof= 38 plf Lag Screw Check Lumber: DFL No.2 Uplift Demand Design Wind Pressure p= -34.3 psf(Zone 2) Trib. Depth for Each Rail dpv=U2= 3.32 ft Trib.Depth for Each Rail bp,=W/2= 1.68 ft Screw Anchor Spacing spy='_?4;00;ft(max.) Uplift Force on Each Screw, Portrait UL=(p+Qpv)* pv Spy= -416 lbs(Upwards) • Uplift Force on Each Screw,Landscape Uw=(p+Qpv)*bpv*spy= -211 lbs(Upwards) Design Uplift Force P„p1iiz=0.6*[Max(U ,Uw)]= -250 lbs(Upwards) Uplift Capacity NDS 2015 Adjustment Factors CD= 1.6 CM= 1 Ct= 1 SG= 0.50 CA,Ceg,Cg,Cd;,Ctn are not appicable Speicfic Gravity of Lumber SG= 0.50 NDS Supplement Table 4a Diameter of Lag Screw D= • 5/16 in Withdraw Design/in 1800*SG312*D31"= 266 lbs/in NDS 2015 12.1-1 Depth of Embeddment Ip=;'2:50 in Total Nominal Withdrawal Value W=W*1p= 665 lbs Withdrawal Design Vaule W'=W*CD*CM*Ct 1064 lbs NDS 2015 Table 11.3.1 Demand-Capacity Ratio P„pttft 1 W= 0.23 < 1 (OKAY] Beam/Top Chord Check Lumber:DF-L No.2 • Moment Demand Span: 1 Orientation j II(ft) p;(lbs) Lenght(ft): 13 Portrait 1 3.9 -416 - 2 8.7 -416 Linear Dead Load wa= 38 plf Wind Load, Portrait UL= -416 lbs " Wind Load, Landscape Uw= -211 lbs #of Attachment per Rafter NA= ``2 wdx2 M(x)=Rj(x—Li)—13i(x-1.1)— 2 i 1 1200 I f • ,i ; , 1 , 1000 ( _,( I —1—= , 4- 800 —1-- 1-._ I —}vim 1 c 600 — — s — 1 • + d ci- 400 !—T — 1 '— — --1 — i ___T 200 — I 0 0.0 2.0 4.0 6.0 8.0 10.0 12.0 14.0 Length x(ft) Ma,Moment . Dead 967 lb-ft Dead+Wind 1026 lb-ft Dead+Snow 967 lb-ft Moment Capacity Framing Member Size ;':`2x8 Lumber Grade: DF-L No.2 CM= 1 Ct= 1 Cr= 1.15 CF= 1.2 fb= 900 psi Ct„and C1 are not applicable Breadth b= 1.50 in Depth d= 7.25 in Section Modulus S, =bd2/6= 13.1 in3 Bending Stress Capacity Fb= CM*Ct*Cr*CF*fb= 1242 psi Table 4.3.1 NDS 2015 Co Fb'=Co*Fb Ma*S„ ASD Load Design Bending DCR Dead 0.9 1118 psi 883 psi D 883 psi 0.79 OKAY Dead+Wind 1.6 1987 psi 937 psi .6W+.6D 562 psi 0.28 OKAY Dead+Snow 1.15 1428 psi 883 psi D+S 883 psi 0.62 OKAY Deflection Limit E= 1600 ksi I= 47.63 in4 Transient Deflection 0.277 in Transient Deflection Allowed 564 > 180 [OKAY] Total Deflection 0.389 in Total Deflection Allowed 401 > 120 [OKAY] SEISMIC WEIGHT COMPARISON/ANALYSIS-(PER CBC 2016 Part 10 Chapter 4 Section 402 PV System Weight Module Model LG-400N2-A5 Panel Weight Wpanei= 47.74 lbs Number of Panels Npv= 12 Total PV System Weight WPV=Wpanel*NPv= 572.88 lbs Existing Roof Weight , Roof Weight QD= 16.0 psf Building Length Lbuild = 85 ft Building Width Wbuild = 35 ft Roof Area Abuild= 2975 ft2 Building Perimeter Pbulld= 240 ft Wall Height ht= 8 ft Wall weight Qwall= 15 psf Interior wall weight Qint= 10 psf Roof Load Wfloor=Abuild*QD= 47600 lbs Wall Load Nwall= ht/2*Qwall*Pbuild +Abulld*Qint/2= 29275 lbs Total Story Weight Wbuild =Wfloor Wwalr= 76875 lbs Percentage Weight Increa WPV/Wbund= 0.75% < 10%e OKAY