Loading...
HomeMy WebLinkAboutSOLR-20-0235 City of Arcadia, CA Permit NO. SOLR-20-0235 Development Services Department Permit Type:Solar 240 West Huntington Drive,Post Office Box 60021 ` Arcadia,CA 91066-6021 Work Classification:Solar-Residential Over 10 KV (626)574-5416 Permit Status:Issued ARCADIA Issue Date:02/18/2020 Expiration: - Addr NO. Dir Prefix Street Name Street Suffix Unit City,State,Zip Parcel Number 1716 N SANTA ANITA AVE Arcadia, CA 91006-1645 5765022010 Contacts ALEXANDER,MAGDI G CO TR ALEXANDER Owner True Power Solar Contractor AND CHAVOSHI TRUST 201 Clark AVE,Pomona,CA 91767 `'1716 santa anita AVE (714)676-8888 970591 Description:ROOF MOUNTED SOLAR SYSTEM 42 MODULES 225 Valuation: $ 0.00 Tenant AMP SERVICE. Total Sq Feet: 0.00 Plan Check# Plan 8 Fees Amount Payments Amount Paid Building Plan Check Fee Residential $50.00 Total Fees $324.72 Distribution Panel $16.48 Cash/Receipt#REC-03891-20 $324.72 Electrical Permit Issuance Fee $47.01 Fire Plan Check Fee Residential $50.00 Amount Due: $0.00 Inverters $77.78 Panels $82.45 Solid Waste Management Fee 2 $1.00 .ir COMPLETED Total: $324.72 CALLS FOR INSPECTIONS -1(vi L 3 -16i- ZO "--- Request for inspection by telephone at 626-574-5450. Leave a message requesting the address,timeframe and what inspection item is needed. This permit/plan review expires by time limitation and becomes null and void if the work authorized by the permit is not commenced within 180 days from the date of issuance or if the permit is not obtained within 180 days from the date of plan submittal.This permit expires and becomes null and void if any work authorized by this permit is suspended or abandoned for 180 consecutive days or if no progressive work has been verified by a City of Arcadia building inspector for a period of 180 consecutive days. 94) February 18, 2020 Issued By: Date February 18,2020 Page 1 of 1 03,IF0gp,4�0 4b PERMIT/PLAN REVIEW APPLICATION �e,14h . Development Services Department,240 West Huntington Drive,Post Office Box 60021 —*alp alu Arcadia, CA 91066-6021, (626) 574-5416,Fax (626) 447-9173 City of Arcadia LICENSED CONTRACTOR'S DECLARATION WORKERS'COMPENSATION DECLARATION ❑ I hereby affirm under penalty of perjury that I am licensed under provisions of I hereby affirm under penalty of perjury one of the following: Chapter 9(commencing with Section 7000,of Division 3 of the Business and Professions Code,and my license is in full force and effect. 0 I have and will maintain a certificate of consent to self-insure for workers' License Class {))C`i( , License No.4, ,k'SCJ i Exp. Date 31311Z0.-• • compensation, as provided for by Section 3700 of the Labor Code, for the Signature of Contractor 1' performance of the work for which this permit is issued. OWNER-BUILDER DECLA'� '1 N 24 I have and will maintain workers'compensation insurance,as required by Section ❑ I hereby affirm under penalty of perjury that I am exempt from the Contractors 3700 of the Labor Code,for the performance of the work for which this permit License Law for the following reason(Section 7031.5,Business and Professions is issued.My workers '�c�om ns insurance carrier and policy numbers are: Code.Any city or county which requires a permit to construct,alter,improve, Carrier `J`-1 demolish,or repair any structure,prior to its issuance,also required the applicant ,, i. 7 G for such permit to file a signed statement that he or she is licensed pursuant to the Policy Number provisions of the Contractors License Law(Chapter 9(commencing with Section (This section need not be completed if the permit is for one hundred dollars or less) 7000)of Division 3 of the Business and Professions Code)or that he or she is exempt there from and the basis for the alleged exemption. Any violation of ❑ I certify that in the performance of the work for which this permit is issued,I shall Section 7031.5 by any applicant for a permit subjects the applicant to a civil not employ any person in any manner so as to become subject to the workers' penalty of not more than five hundred dollars($500)): compensation Laws of California,and agree that if I shor,ld become subject to the workers'compensation provisions of Section 371,1 .' e Labor Code,I shall ❑I, as owner of the property, or my employees with wages as their sole forthwith comply with those provisions. ir compensation,will do the work,and the structure is not intended or offered forate 2/t 6020Signature , sale(Section 7044,Business and Professions Code:The Contractors License Law does not apply to an owner of property who builds or improves thereon, C--------/ or who does such work himself or herself or through his or her own employees,provided that such improvements are not intended or offered for WARNING: Failure to secure Workers'Compensation coverage is unlawful, sale.If,however,the building or improvement is sold within one(1)year of and shall subject an employer to criminal penalties and civil fines up to one completion,the owner-builder will have the burden of proving that he or she hundred thousand dollars($100,000),in addition to the cost of compensation, did not build or improve for the purpose of sale). damages as provided for in Section 3706 of the Labor Code, interest, and attorney's fees. ❑I, as owner of the property, am exclusively contracting with licensed contractors to construct the project(Section 7044,Business and Professions Code:The Contractors License Law does not apply to an owner of property CONSTRUCTION LENDING AGENCY who builds or improves thereon,and who contracts for such projects with a I hereby affirm under penalty of perjury that there is a construction lending agency contractor(s)licensed pursuant to the Contractors License Law). for the performance of the work for which this permit is issued (Section 3097, Civil Code). ❑ I am exempt under Section 7044,Business and Professions Code,for this reason: Lender's Name Date Signature Lender's Address IMPORTANT: APPLICATION IS HEREBY MADE TO THE BUILDING OFFICIAL FOR A PERMIT SUBJECT TO THE CONDITIONS AND RESTRICTIONS SET FORTH ON THIS APPLICATION AND THE FOLLOWING: 1. The City's approved plans and permit inspection card must remain on the job site for use by City inspection personnel. 2. Final inspection of the work authorized by this permit is required.A Certificate of Occupancy must be obtained prior to use and occupancy of new buildings and structures. 3. Per South Coast Air Quality Management District(AQMD)regulations,renovation and remodeling work that results in the removal,stripping,or altering of asbestos containing materials requires an asbestos survey and removal prior to disturbing the asbestos.Please contact AQMD at(909)396-2000 for further information. I ar are S`� 0 t — "— " Title PRINT NAME I certify that I have read this application and state that the above information is correct and that I am the owner or duly authorized agent of the owner. I agree to comply with all City Ili 'inances and State Laws relating to building construction. I hereby authorize representatives of the City of Arcadia to enter upon the abo entioned property for inspection purposes. it ignature ' ate FROM JUNCTION BOX TO ROOF EAVE EMT TYPE CONDUIT WILL RUN OVER PHOTOVOLTAIC SYSTEM 13.02 KW DC THE ROOF AT 3 1/2"HEIGHT,THEN UNDER THE EAVE TO PV EQUIPMENT ROOF PLAN 42 Mission Solar Energy 310W Modules(MSE310SQ8T) 42 Solar Edge P320 Power Optimizers Drawn By:Narek A. 1 Solar Edge 11.4 Kw Inverter(SE11400H-US) Note:All exposed equip/conduit shall be painted to match roof/wall. Note:Existing roof tile to be maintained K I o °:' 0 0 r —_�_ 7 I ---I l I 0000 �/ ,') I o ❑ ❑ ❑ ❑ ( ON ti. o..I b b b b �,C 'Yh a a a a a L- CONTRACTOR 1 y -,,;:'=,./ ❑ a _ True Power Solar b D c D ��- Solar Array 1 Address: Solar Array 3 - -,p1 ❑ a ❑ a 4 Mission Solar 310W 201 Clark Ave 4 P320 Optimizers Pomona,CA 91767 d 4 Mission Optimizers 310W b D c O I Phone Number: > ❑ a ❑ a Pitch:21 Deg Is 4 P320 i Orientation:180 Deg (714)676-8888 Is Pitch:21 Deg b D c D -E Orientation:180 D 1 ❑ a ❑ a Solar Array 2 Lic type:C.46 co b D c D ( 12 Mission Solar 310W Lic#970591 c ❑ a ❑ a 12 P320 Optimizers re I Pitch:21 Deg b D c D - , ) Orientation:90 Deg Z Solar Arra 4I ❑ e ❑ e 'l.e. TRUE PwwER Array 22 Mission Solar 310W b D c D , L.--.l --4N:--4N: S SOL AR 22 P320 Optimizers ❑ a . Pitch:21 Deg — Ll: Orientation:270 Deg b 0 c D : Lf. ':I o b D c D Chzv2 b D c ❑ c D o c D : o o- J/ B 1, ---. o 310 vu-0 SARETH YIP ` 1716 N SANTA ANITA AVE I ARCADIA,CA 91006 INV ACD 180. SP FEBRUARY 03.zozo SCALE .... w I I I I AS INDICATED I 0 1 5 10ft "� w SYSTEM SAM ENGINEERING 20051 MEADOW CREEK CIR. WALNUT, CA 91789 Structural Calculations for: Sareth Yip Residence 13.02 kW DC Photovoltaic Array Addition 1716 N. Santa Anita Ave. Arcadia, CA 91006 Owner/Developer: True Power Solar _ 201 Clark Ave. Pomona, CA 91767 a)a) _ va' U 7 T w i I UJ c J m p '. \ F I o Q Z February 3, 2020 I_ , ; z Q \c>6 1--1 ' > OiN O 1 b oY I I I 1 WCC .\ c6' ! Z 2 \0.� --t -- - O a 0 cri Job#: 20-1061 -t'7 J S �- -QppPESS fgyq\ . 1 O j in W Z PNEN , <�� ! Q 2 0 ,g A \ � � c�1 RI i ' d ¢ 1 '45 Q,` —GI- p. 3/3 /20 _t.-7'.' 6.1\1 ^�1 l I i -- V' 1 I j ,,:ah., � ,/ C til I 0l E; dia, !�iO I w CO �,6:li4_31. 20 • 2;5•ti __, Page 1 of 4 SAM ENGINEERING 20051 MEADOW CREEK CIR. WALNUT,CA 91789 SOLAR RESIDENTIAL ROOF/BUILDING CHECK Check Photovoltaic Array Addition-2019 California Building Code(CBC) Gravity Design Loads: Roof Type: M concrete tile over 1/2"sheathing over rafters over 5/8"gypsum board Live Load: 20.0 psf Dead Load: Roofing Material: 12.0 psf Sheathing: 1.5 psf Roof Framing Members: 2.5 psf Drywall: 1.5 psf Insulation: 1.0 psf Miscellaneous: 1.5 psf Solar Array&Rack System 2.75 psf —Additional Load Applied Roof Dead Load w/o Solar Array= 20.00 psf Over<50%of Roof Area Roof Dead Load at Solar Array= 22.75 psf Total Roof Load w/o Solar Array= 40.0 psf Total Roof Load at Solar Array= 42.8 psf Area of Solar Array Addition(for gravity check)= 756 ft2 Total Area of Affected Rafters(for gravity check)= 1900 ft2 Area of Solar Array Addition(for seismic check)= 756 ft2 Total Area of Affected Roof(for seismic check)= 1900 ft2 Check Additional Gravity Loads on Rafters: Total Load Increase at Affected Rafters= 1.09 psf %of Total Load Increase= 2.74% < 5.0% OK Per CBC 3403A.3 Additional Solar Array Weight is Structurally Acceptable Check Additional Gravity Loads on Lateral Resisting System: Dead Load Increase at Entire Roof= 1.09 psf %Dead Load Increase on Entire Roof= 5.47% < 10.0% OK Per CBC 3403A.4 Additional Solar Array Lateral Load is Structurally Acceptable Page 2 of 4 SAM ENGINEERING Date: E1 20051 MEADOW CREEK CIR. #: WALNUT,CA 91789 Es: ROOF MOUNTED SOLAR PANELS Earthquake Design per ASCE 7-16-13.3.1 Design Parameters Site Class= D Per Table 1613A.3.2 Latitude,deg Longitude,deg Short Period S.A.,Ss= 1.976 2015 NEHRP Provisions 34.1625 -118.0314 Site Coefficient,Fa= 1.20 Table 1613A.3.3(1) Sms=FaSs= 2.37 EQ 16A-37 Sos=2/3 Sms= 1.58 EQ 16A-39 Importance Factor,IP= 1.00 Section 13.1.3 Height of Equipment,z= 12.00 ft Height of Roof,h= 12.00 ft Weight of Panels to each Mount,W,= 41.00 lbs ap= 1.00 Table 13.6-1 Rp= 2.50 Table 13.6-1 Determine Fp,Seismic Design Force(STRENGTH LEVEL) Fp=(0.4apSosWp)(1+2z/h)/(Rp/Ip)= 31 lbs EQ 13.3-1 [Not Greater Than:] Fp=1.65DsWPIP= 104 lbs EQ 13.3-2 [Not Less Than:] Fp=0.3SpsWpIp= 19 lbs EQ 13.3-3 Use Fp= 31 lbs at each Roof Mount Bracket Page 3 of 4 • Sht: W1 SAM ENGINEERING Date: 20051 MEADOW CREEK CIR. #. WALNUT,CA 91789 A: -- ROOF MOUNTED SOLAR PANELS Components and Cladding-Wind Load Design per ASCE 7-16,30.4.2-h<60 ft Design Parameters Design Wind Velocity(3s Gust),V= 110 mph Wind Exposure= C Mean Panel Height= 12.00 ft Total Effective Area of Typical Array= 756 ft2 Panel Area to Each Support= 18.00 ft2 Angle of Panels= 21 degrees(worst case) a= 3 ft(3ft.Min.) Determine Wind Force at Each Roof Mount qh=0.00256 K,K2 Kd V2 I= 13.4 psf Load case 0.6*qh K2= 0.85 Table 30.3-1,Page 317 K22= 1.0 Figure 26.8-1,Page 252-253 Kd= 0.85 Table 26.6-1,Page 250 1= 1.00 Internal Pressure Coeff.=GCP;= 0 +/-(Figure 6-5) V=0" v=180' GCP(Zone 1)= 0.45 -0.85 Per Figures 30.4-1 thru 30.4-7 GC,(Zone 2)= 0.45 -1.60 Per Figures 30.4-1 thru 30.4-7 GC,(Zone 3)= 0.50 -2.60 NO PANELS IN ZONE 3 (+)P=qh(GC,-GC„,)= 10.0 -21.5 psf,Positive Wind(10 psf min)-Worst Case Lateral Load at Each Mount= 65 -139 lbs Compression/Uplift at Each Mount= 168 -361 lbs Roof Mount is attached to roof sheathing&roof members w/(1)5/16"x 3.5" Lag Bolt w/Min.2.5"thread embed per TRUE POWER SOLAR. Allowable Loads for 5/16" Diameter Lag Screw per the 2018 NDS: (Table 11.2A) Withdrawl= 266 lb/in x 2.5"embed x (Cd=1.6)= 1064 lbs (Table 11K) Shear= 120 lb x (Cd=1.6) = 192 lbs SOLAR ARRAY ATTACHMENT METHOD IS STRUCTURALLY ACCEPTABLE. Page 4 of 4