HomeMy WebLinkAboutSOLR-19-1794 tji-i
r" ' A�� � a PermitNO SOLI 19`4.,-
: 794
City of Arcadia, CAT p
a ,,p
Development Services Department `" , � tType Solar
a
240 West Huntington Drive,Post Office Box 60021 ( 'd ,-Ii rs, l 4mn %-3-,,,,,,,,,,,,:,;;;10--,,,,,, k
�' g ' Work C asst cation Solar Residential Over 10 KV
Arcadia,CA 91066-6021 �} �a �� r � �� � � c°
'4'.4'*(''‘?rni (626)574-5416 - S � 4M, -' PermrtStat is Issued
T `fir" -r "4a 44,1',.°"4,44°' " "a
ARCADIA 3issu to 09/06/2019 Expiration: 03/04/2020
Addr NO. Dir Prefix Street Name Street Suffix Unit City,State,Zip Parcel Number
135 W Lemon AVE Arcadia,CA 5782020006
lIgEMEEMCIESIMESZIEZEMEMEEZa
:. a ..,,.
Contacts
CHANG,JENNY C Owner Sunside Solar Inc. Contractor
135 W Lemon Ave,Arcadia,CA 91007 9040 Telstar AVE#128,El Monte,CA 91731
(888)997-8168995897
a
Description:ROOF MOUNT PV SYSTEM 48 MODULES/MICRO,80 i Valuation: $ 0.00 Tenant
AMP COMBINER BOX
Total Sq Feet: 0.00 Plan Check# Plan#
Fees Amount Payments Amount Paid
Building Plan Check Fee Residential $50.00 Total Fees $324.72
Distribution Panel $16.48 Cash/Receipt#REC-02399-19 $324.72
Electrical Permit Issuance Fee $47.01
Amount Due: $0.00
Fire Plan Check Fee Residential $50.00
Inverters $77.78
Panels $82.45
Solid Waste Management Fee 2 $1.00
Total: $324.72
he
CALLS FOR INSPECTIONS
4/-3-2e.> �4 C Request for inspection by telephone at 626-574-5450. Leave a message
requesting the address,timeframe and what inspection item is needed.
This permit/plan review expires by time limitation and becomes null and
CP/METED void if the work authorized by the permit is not commenced within 180 days
from the date of issuance or if the permit is not obtained within 180 days
from the date of plan submittal.This permit expires and becomes null and
void if any work authorized by this permit is suspended or abandoned for 180
consecutive days or if no progressive work has been verified by a City of
Arcadia building inspector for a period of 180 consecutive days.
CA/V._
September 06, 2019
Issued By: Date
September 06,2019 Page 1 of 1
OF ARe
CI y PERMIT/PLAN REVIEW APPLICATION
-;:ftOP e7 Development Services Department,240 West Huntington Drive,Post Office Box 60021
%I.
*40ity,c" Arcadia, CA 91066-6021, (626) 574-5416,Fax(626) 447-9173
City of
4rcadia
Ili,LICENSED CONTRACTOR'S DECLARATION WORKERS'COMPENSATION DECLARATION
0 I hereby affirm under penalty of perjury that I am licensed under provisions of I hereby affirm under penalty of perjury one of the following:
Chapter 9(commencing with Section 7000,of Division 3 of the Business and
Professions Code, my license is in full force an effect. / ❑ I have and will maintain a certificate of consent to self-insure for workers'
/ /i compensation, asprovided for bySection 3700 of the Labor Code, for the
License Class License No. Exp. Date�+6 P
performance of the work for which this permit is issued.
Signature of Contractor �y
ai
OWNER-BUILDER DECLARATION I have and will maintain workers'compensation insurance,as required by Section
IDI hereby affirm under penalty of perjury that I am exempt from the Contractors 3700 of the Labor Code,for the performance of the work for which this permit
is issued.My workers'compensation insurance carrier and policy numbers are:
License Law for the following reason(Section 7031.5,Business and Professions . n' ��
Code.Any city or county which requires a permit to construct,alter,improve, ;;Carrier c(
demolish,or repair any structure,prior to its issuance,also required the applicant =� !rrq
for such permit to file a signed statement that he or she is licensed pursuant to the Policy Number (.i'�
'",,,,t...
�
1e(This section need not be ompleted if the permit is for one hundred dollars or less)
provisions of the Contractors License Law(Chapter 9(commencing with Section tf{
7000)of Division 3 of the Business and Professions Code)or that he or she is
exempt there from and the basis for the alleged exemption. Any violation of fI certify that in the performance of the work for which this permit is issued,I shall
Section 7031.5 by any applicant for a permit subjects the applicant to a civil ?loot employ any person in any manner so as to become subject to the workers'
penalty of not more than five hundred dollars($500)): If,Compensation Laws of California,and agree that if I should become subject to the
,workers'compensation provisions of Section 3700 of the Labor Code,I shall
IDI, as owner of the property, or my employees with wages as their sole ' -forthwith comply with those provisions.
compensation,will do the work,and the structure is not intended or offered for .
sale(Section 7044,Business and Professions Code:The Contractors License Date q. v(1 Signature
Law does not apply to an owner of property who builds or improves thereon, ``
or who does such work himself or herself or through his or her own
employees,provided that such improvements are not intended or offered for WARNING: Failure to secure Workers'Compensation coverage is unlawful,
sale.If,however,the building or improvement is sold within one(1)year of and shall subject an employer to criminal penalties and civil fines up to one
completion,the owner-builder will have the burden of proving that he or she hundred thousand dollars($100,000),in addition to the cost of compensation,
did not build or improve for the purpose of sale). damages as provided for in Section 3706 of the Labor Code, interest, and
attorney's fees.
❑I, as owner of the property, am exclusively contracting with licensed
contractors to construct the project(Section 7044,Business and Professions
Code:The Contractors License Law does not apply to an owner of property CONSTRUCTION LENDING AGENCY
who builds or improves thereon, and who contracts for such projects with a I hereby affirm under penalty of perjury that there is a construction lending agency
contractor(s)licensed pursuant to the Contractors License Law). for the performance of the work for which this permit is issued (Section 3097,
Civil Code).
❑ I am exempt under Section 7044,Business and Professions Code,for this reason:
`-
Lender's Name
-
Date .6 f Signature ,� Lender's Address
EN/11'0R : APPLI ATION IS HEREBY MADE TO THE BUILDING OFFICIAL FOR A PERMIT SUBJECT TO THE CONDITIONS AND
RESTRICTIONS SET FORTH ON THIS APPLICATION AND THE FOLLOWING:
1. The City's approved plans and permit inspection card must remain on the job site for use by City inspection personnel.
2. Final inspection of the work authorized by this permit is required.A Certificate of Occupancy must be obtained prior to use and occupancy of new buildings
and structures.
3. Per South Coast Air Quality Management District(AQMD)regulations,renovation and remodeling work that results in the removal,stripping,or altering
of asbestos containing materials requires an asbestos survey and removal prior to disturbing the asbestos.Please contact AQMD at(909)396-2000 for
further information.yy q
Name 5l,Q�9., U(irr Title .7.),A-47,--,
NAME
:jI certify that I have read this application and state that the above information is correct and that I am the owner or duly authorized agent of the owner.
r;,,:Iagree to comply with all City ordinances and State Laws relating to building construction. I hereby authorize representatives of the City of
!, Arcadia to enter upon the above-mentioned property for inspection purposes.
t:[i x /;'
S'gnature .q4 (1, ....e- /JDate 6 i
GENERAL NOTES: O PV LAYOUT NOTE:RAPID SHUTDOWN BUILT INTO EACH MICROINVERTER, REVISION
SCALE:CIVIL 1:15 NO ADDITIONAL RAPID SHUTDOWN EQUIPMENT REQUIRED. DATE NO
1.OUTDOOR EQUIPMENT SHALL BE AT LEAST NEMA 3R RATED.
2.ALL SPECIFIED WIRING IS BASED ON THE USE OF COPPER.
3.CONTRACTOR SHALL OBTAIN ELECTRICAL PERMITS AND SHALL COORDINATE r,y
ALL INSPECTION,COMMISSIONING AND ACCEPTANCE WITH THE CLIENT, Vl JTi N Al VENT
UT LTTY CO.AND CITY INSPECTORS AS NEEDED.
4.DRAWINGS ARE DIAGRAMMATIC ONLY,ROUTING OF RACEWAYS SHALL BE AT 0 ❑ 5,.\\''
� ❑ 4. ELGIN
THE OPTION OF THE CONTRACTOR UNLESS OTHERWISE NOTED AND SHALL BE Z e \ ❑ 3:12
COORDINATED WITH OTHER TRADES. ppII N 4,"--x'°•
5.IP DISTANCES OF CABLE RUNS ARE DIFFERENT THAN SHOWN,THE 4,'f a q N
CONTRACTOR SHALL NOTIFY ELECTRICAL ENGINEER TO VALIDATE THE WIRE FF33!! ,7j ij
31S151y1y1SiS1
SIZE.FINAL DRAWINGS WILL BE RED-LINED AND UPDATED AS APPROPRIATE. In., I �� qac •.
6.WHENEVER A DISCREPANCY TN QUANTITY OF EQUIPMENT,ARISES ON THE a N In•,. Bf ri ,z
DRAWINGS OR SPECIFICATIONS,THE CONTRACTOR SHALL BE RESPONSIBLE FOR �epE 0 SLOPE ,Sys S7 S1 81t Do- I. '^
PROVIDING AND INSTALLING ALL MATERIAL AND SERVICES REQUIRED BY THE •3'"1_23:12ICm10 w
MI
STRICTEST CONDITIONS NOTED ON THE DRAWINGS OR IN THE SPECIFICATIONS 0 VENT >
TO ENDURE COMPLETE COMPLIANCE AND LONGEVITY OF THE OPERABLE y
SYSTEM REQUIRES BY THP.ARCHI7P.CT/P.NGINF.P.R. <-:1
I- 01
7.ALL BROCHURES.OPERATION MANUALS,CATALOGS,SHOP DRAWINGS,ETC. N (��fT ' ir, NI������� 3.12 w m';
SHALL BE HANDED()VERTU THE OWNERS REPRESENTATIVE AT THE Ps
� i 3 G 3SP,+�
8.ALL WIRING
WORK. p,+• . FIRFUWE '°le... 2 TU1.2 N°'
S.ALL WIRING CONCEALED IN WALL AND CEILING SPACES SHALL,BE IN METAL �/•", E
G'V.' F=.,p U
CONDUIT. COMBINQt SPANISH �e:r ..J r o,-7m.,,7
FlRE3ANE '"-,^I^ SLOP Up: L' 4 61 m
9.THE SEISMIC BRACING AND ANCHORAGE OFUI ELECTRICALNESFR CONDUITS SHALL BOX TRE ROOF V.
BE IN ACCORDANCE WITH THE"SMACNA"-liUIDLINES FOR SEISMIC RESTRAINS PFRFORMANCE 3:12 3 =,�
OF MECHANICAL SYSTEMS AND PLUMING PIPING SYSTEMS. TER QwqN 3
10.ALL OF THE LISTED SYSTEMS REQUIRED THAT THE SEISMIC LATERAL FORCE
GARAGE _SLOPE . -'�• to s•pl SLOPE N
F INCLUDING CONSIDERATION OF a^P AND NP BE DETERMINED AT EACH LEVEL 3:12
OF THE BUILDING SO THAT BRACE SPACING CAN BE CALCULATED.THE ,"1°I° -1
DISTRICT STRUCTURAL ENGINEER CAN APPROVE THE SEISMIC LATERAL FORCE (EI VQdT SLAM C VENT `Z
DETERMINATION. TW. 31121"•mm pop In•mm 4 \ I- w o
11.A COPY OF THE CHOSEN BRACING SYSTEM(S)INSTALLATION GUIDE/MANUAL ` Z > a,
LU Q
SHALL BE ON THE JOB SITE PRIOR TO STARTING THE INSTALLING OF HANGERS r I� Tram, I. II ELOPE 0 0 1
AND/OR ORALES. Ira* -40 3:12 �� W W U
12.WHEN INSTALLING DRILLED-IN ANCHORS AND/OR POWDER DRIVEN PINS IN ��� ��
EXISTING NON-PRESTRESSED REINFORCED CONCRETE,USE CARE AND CAUTION - 'rmm N 3:12 N G
TO AVOID CUTTING OR DAMAGING THE REINFORCED BARS.WHEN INSTALLING F-7
n u
THEM INTO EXISTING PRESTRESSED CONCRETE TENDONS BY USING A 1 - • Q °d
NON-DESTRUCTIVE METHOD PRIORTO INSTALLATION.EXERCISE EXTREME E _
CARE AND CAUTION TO AVOID CUTTING OR DAMAGING THE TENDONS DURING -�A SWP �1 b U
INSTALLATION.MAINTAIN A MINIMUM CLEARANCE OF ONE INCH BETWEEN THE ❑ 4 0 0
REINFORCEMENT AND THE DRILLED-IN ANCHOR. 3:1 -I \ J •12 Si = STRING 1
I3.TUE WORKING CLEARANCES AROUND THE EXISTING ELECTRICAL Hjl'„1fr(E) S2 = STRING 2 ..,,..--
EQUIPMENT
f
EQUIPMENT AS WELL AS TTIE NEW ELECTRICAL EQUIPMENT WILL BE Typ, S3 = STRING 3'"' 0
MAINTAINED IN ACCORDANCE WMI NEC 110.26. 54 = STRING 4 . .2
14.SPACING MUST BE MAINTAINED BETWEEN ANY PLUMBING SEINER VENTS -I
RXTP.NDING THROUGH THE ROOF AND THE UNDERSIDE OF THE PHOTOVOLTAIC NOTE:NEW CONSTRUCTION
PANELS(G'MINIMUM RECOMMENDED).
s
IS.SMOKE ALARMS AND CARBON MONOXIDE DETECTORS SHALL BE LOCATEDa
AS REQUIRED PER SECTIONS R3141C R315 WTRIIN THE CALIFORNIA RESIDENTIAL � B.
CODE(CRC). k, Op
16.SMOKE ALARMS SOLELY BATTERY OPERATED FOR THE PHOTOVOLTAIC LEGEND 6 114 y
SYSTEM DOES NOT INVOLVE THE REMOVAL OF INTERIOR WALL AND CEILING
FINISHES INSIDE THE HOME. H
17.CONDUCTORS EXPOSED TO SUNLIGHT SHALL BE LISTED AS SUNLIGHT PV SYSTEM: 48 X 330W = 15.84KW (DC) r
RESISTANT.(NEC 300.601,310.SD) PANASONIC VBH330SA17 qY N
IR.GROUNDING BUSHINGS ARE REQUIRED AROUND PRE-PUNCHED CONCENTRIC (626"x41.5 DX 1.6") > Z C
KNOCKOUTS ON THE DC SIDE OF THE SYSTEM.(NEC 250.97) MODEL: PANASONIC VBH330SA17 m D_ o4
19.THE GROUNDING ELECTRODE CONDUCTOR MUST DE PROTECTED FROM 330W PV PANEL, SEE SHEET E-3 .: a _d
PHYSICAL DAMAGE IF SMALLER THAN q6 COPPER WIRE.(NEC 2S0.64B) I VLSI ENPHASE COMBINER BOX d
20.OROUN DING ELECTRODE CONDUCTOR WILL BE CONTINUOUS,EXCEPT FOR o :
SPLICES OR JOINTS AT El/SEARS WITHIN LISTED EQUIP MENT.(NEC 250.64 C) � INVERTER: ENPHASE MICROINVERTERS IQ7X-96—X—US w r-
21.RACEWAY FOR GROUNDING ELECTRODE CONDUCTOR SHALL BE BONDED AT rpm PERFORMANCE MONITOR SEE SHEET E-4 . 8
EACH END.(LEC 250.64(E)
Li 4...,
22.EQUIPMENT GROUNDING SHALL BE INSTALL AT EACH INDIVIDUAL MODULE
AT THE.MANUFACTURF..S RECOMMENDED POINT OF ATTACHMENT USING AC/D AC DISCONNECT/RAPID SHUTDOWN CONTROLLER RACKING: SOLAR WAREHOUSE , SEE S-1, S-2 & S-3 Date'
08
LISTED LUG SUITABLE FORMAT PURPOSE.(WITH OR WITHOUT WEEK OR SHUW _ _
/M/1a19
CLIPS) Mil MAIN SERVICE ELEC. PANEL INSTALLATION GUIDE SEE SHEET S-1
A5N1Urno
HOUSE. Drawn:SONDE CONDUIT THAT IS EXPOSED MUST BH PAINTED THE SAME COLOR AS THE RAFTER: 2x8 ® 16" O.C., ROOF RAFTER DE SOLAR
Sheet:
24.DIRECTORY.A PERMANENTPLAQUE OR DIRECTORY DENOTHING ALL (E) EXISTING t:
ELECTRIC POWER SOURCES ON ORIN THE PREMISES MUST BE INSTALLED AT
EACH SERVICE EQUIPMENT LOCATION AND ALL INTERCONNECTED ELECTRIC
POWER PRODUCTION SOURCES.705.10