Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
Untitled
City of Arcadia, CA Permit NO.SIGN-20-0117 Development Services Department Permit Type:Sign 240 West Huntington Drive,Post Office Box 60021 Work Classification:Sign-Illuminated Arcadia,CA 91066-6021 (626)574-5416 Permit Status:Issued ARCADIA Issue Date:01/21/2020 Expiration: Addr NO. Dir Prefix Street Name Street Suffix Unit City,State,Zip Parcel Number 400 S Baldwin AVE Arcadia, CA 91007-1900 5775031034 Contacts SANTA ANITA BORROWER LLC C/0 Owner AD ELECTRICAL ADVERTISING INC* Contractor WESTFIELD SANTA ANITA 9437 VALLEY BLVD,ROSEMEAD,CA 91770 400 (626)448-1166 927951 Description:LED SIGN FOR SANRIO Valuation: $ 3,000.00 ? Tenant SANRIO Total Sq Feet: 0.00 Plan Check H Plan 8 Fees Amount Payments Amount Paid Building Issuing Fee $47.01 Total Fees $364.14 Building Permit Fees $120.35 Cash/Receipt#t REC-03643-20 $364.14 Electrical Permit Issuance Fee $47.01 Amount Due: $0.00 Sign and Branch Circuit $65.86 Sign Connection $16.48 Sign Plan Review $60.18 Solid Waste Management Fee $6.25 Solid Waste Management Fee 2 $1.00 Total: $364.14 CALLS FOR INSPECTIONS Request for inspection by telephone at 626-574-5450. Leave a message 2requesting the address,timeframe and what inspection item is needed. -�v�—zc� �-/��L This permit/plan review expires by time limitation and becomes null and void if the work authorized by the permit is not commenced within 180 days from the date of issuance or if the permit is not obtained within 180 days from the date of plan submittal.This permit expires and becomes null and void if any work authorized by this permit is suspended or abandoned for 180 consecutive days or if no progressive work has been verified by a City of Arcadia building inspector for a period of 180 consecutive days. 11. COM &ETED January 21, 2020 Issued By: Date January 21,2020 Page 1 of 1 406.11 1 PERMIT/PLAN REVIEWAPPLICATION ice\ Development Services Department,240 West Huntington Drive,Post Office Box 60021 .4,-,' Arcadia, CA 91066-6021, (626) 574-5416,Fax (626)447-9173 City of Arcadia LICENSED CONTRACTOR'S DECLARATION WORKERS'COMPENSATION DECLARATION DI hereby affirm under penalty of perjury that I am licensed under provisions of I hereby affirm under penalty of perjury one of the following: Chapter 9(commencing with Section 7000,of Division 3 of the Business and Professions Code,and my license is in full force and effect. 0 I have and will maintain a certificate of consent to self-insure for workers' License Class C 4c" License No. 9-219S1 Exp. Date to I`it'2% Signature of Contractor compensation, as provided for by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. OWNER-BUILDER DELL RATION 13-1 have and will maintain workers'compensation insurance,as required by Section 0 I hereby affirm under penalty of perjury that I am exempt from the Contractors 3700 of the Labor Code,for the performance of the work for which this permit License Law for the following reason(Section 7031.5,Business and Professions is issued.My workers'compensation insurance carrier and policy numbers are: Code.Any city or county which requires a permit to construct,alter,improve, Carrier irk[Op p demolish,or repair any structure,prior to its issuance,also required the applicant Policy Number f VESCS025 for such pemtit to file a signed statement that he or she is licensed pursuant to the provisions of the Contractors License Law(Chapter 9(commencing with Section (This section need not be completed if the permit is for one hundred dollars or less) 7000)of Division 3 of the Business and Professions Code)or that he or she is exempt there from and the basis for the alleged exemption. Any violation of certrfy that in the performance of the work for which this permit is issued,I shall Section 7031.5 by any applicant for a permit subjects the applicant to a civil not employ any person in any manner so as to become subject to the workers' penalty of not more than five hundred dollars($500)): compensation Laws of California,and agree that if I should become subject to the workers'compensation provisions of Section 3700 of the Labor Code,I shall ❑I, as owner of the property, or my employees with wages as their sole forthwith comply with those provisions. compensation,will do the work,and the structure is not intended or offered for sale(Section 7044,Business and Professions Code:The Contractors License Date /Zt 16 Signature7---"-I- ML Law does not apply to an owner of property who builds or improves thereon, or who does such work himself or herself or through his or her own employees,provided that such improvements are not intended or offered for WARNING: Failure to secure Workers'Compensation coverage is unlawful, sale.If,however,the building or improvement is sold within one(1)year of and shall subject an employer to criminal penalties and civil fines up to one completion,the owner-builder will have the burden of proving that he or she hundred thousand dollars($100,000),in addition to the cost of compensation, did not build or improve for the purpose of sale). damages as provided for in Section 3706 of the Labor Code, interest, and attorney's fees. ❑I, as owner of the property, am exclusively contracting with licensed contractors to construct the project(Section 7044,Business and Professions Code:The Contractors License Law does not apply to an owner of property CONSTRUCTION LENDING AGENCY who builds or improves thereon,and who contracts for such projects with a I hereby affirm under penalty of perjury that there is a construction lending agency contractor(s)licensed pursuant to the Contractors License Law). for the performance of the work for which this permit is issued (Section 3097, Civil Code). 0 I am exempt under Section 7044,Business and Professions Code,for this reason: Lender's Name Date Signature Lender's Address IMPORTANT: APPLICATION IS HEREBY MADE TO THE BUILDING OFFICIAL FOR A PERMIT SUBJECT TO THE CONDITIONS AND RESTRICTIONS SET FORTH ON THIS APPLICATION AND THE FOLLOWING: 1. The City's approved plans and permit inspection card must remain on the job site for use by City inspection personnel. 2. Final inspection of the work authorized by this permit is required.A Certificate of Occupancy must be obtained prior to use and occupancy of new buildings and structures. 3. Per South Coast Air Quality Management District(AQMD)regulations,renovation and remodeling work that results in the removal,stripping,or altering of asbestos containing materials requires an asbestos survey and removal prior to disturbing the asbestos.Please contact AQMD at(909)396-2000 for further information. Name ?u,P.i / ToN TM-+7 Title (�lJ TR-114.1-o>L PRINT NAME I certify that I have read this application and state that the above information is correct and that I am the owner or duly authorized agent of the owner. I agree to comply with all City ordinances and State Laws relating to building construction. I hereby authorize representatives of the City of Arcadia to enter upon the above-mentioned property for inspection purposes. il 1 i Signature �� Date /2.6 I i 4'-9" i 1'-6" 1,-3„ . ® Saook 111,114:7® 5'-O" NIGHT VIEW INTERNALLY ILLUMINATED REVERSE ALUMINUM CHANNEL LETTER SIGN QUANTITY:ONE(1)SIGN REQUIRED SPECIFICATIONS: LETTERS: CUSTOM FABRICATED INTERNALLY ILLUMINATED CHANNEL LETTER 4 FACE: .09"THICK ALUMINUM PAINT BLUE(PANTONE 2727) • BACKING: 3/16"CLEAR LEXAN. RETURNS: .04 ALUMINUM RETURNS IN 3 INCHES DEEP PAINT BLUE(PANTONE 2727) LETTER SUPPORT: .06"THICK 2"FLAT CUT ALUMINUM PRE-FININSH WHITE ILLUMINATION: 6500K WHITE LEDS WITH POWER SUPPLY MOUNTING SPACE: 1.5"SPACERS TO CREATE HALO GLOW. r r Ia Kea pau61S " `.It i'.. ,_ : 14.. . .414r:.-.:7,1-;,...'!S 7 , 0 Z az 11-C110 �;-� � sawil lie le alis qol aql uo ldam aq of pailnbai sl sfwnneip to las padwels pioipUel sun to Adoo(6)auo :', ztFP .- ., suoleln6auawwano6 He qlv 6u (Idwoo Job a tsuodsaSt lueual •JoloeJluoo Jo/pue loallgoJv s,lueual agl Aq paquan aq of paiinbai we suogipuoo pial;lenloe py "Aluo lualul - u6lsap leJaua6 Jol paMainaJ uaaq aneq s6wMeJp asagl li wgnsej ❑ w . paioN se penoJddy penoidd. o -Z4. --— \ N -s. MalAOH 6uweJa 6uIMJo/N II �s,a S/GN a This sign is intended to be installed in accordance with the requirements of Article 600 of the National Electrical Code and/or other applicable local codes.This includes proper grounding and bonding of the sign. ELECTRICAL ADVERTISING INC JOB LOCATION APPROVED 9437 VALLEY BL., ROSEMEAD, CA 91770 Sanrio at Westfield Arcadia, #304 TEL: 626-448-1166 FAX: 626-448-1161 400 S Baldwin Ave, Arcadia,CA 91007 r '` UL Listed #E328774 CHANNEL LETTER ALUMIUM SUPORRT WStfi• PLE RENN Us B FOREASINCORPORATEDFERTOTHE INSTALLBERINSTRUCTIONS.ITEMS ELOW ALUMINUM FACEWorking Drawing ....!:).:;-.171....!:).:;....!:).:;-....!:).:;-.171 INSTRUCTIONS TO BE FOUND WITH ACTUAL SIGNAGE WELDED TO RETURNS 2" 1„ (NUMBERED ITEMS CORRESPOND TO SECTION DETAIL) .09 FACES,.063 RETURNS / plip pVedITEM# DESCRIPTION pprovedrOas Noted 0 Resubmit 1 REVERSE CHANNEL LETTER 9 pISCONNECT SWITCH These drawings have been reviewed fot gebra design LIGHT EMITTING DIODES(LEDs) 'I 4 intent only. Al!actual fieia conditions are required114FMADED NIPPLE AND COUPLING(FLEX CONNECTOR) CLASS 2ittiONOtTAGe Tena•is Architect and/or W VOLTAGE WIRING(NO CONDUIT REQUIRED) LOW VOLTAGE WIRING FROM LED TO LED j WIRING J�®9ND>?1#le for cumplyirig with all governrllient r i 0 REVERSE CHANNEL LTTTERS —♦ •■ REQUIRE-110e{1)copy of this landlord stamped set ofraw SUPPLY • required to be kept on the job site at all((mai CLEAR LEXAN BACK I'L © FLEX(FLEXIBLE CONDUIT)/LIQUID TIGHT CONNECTIONS • • 4 „pnwrR OLI1l`1110 DRILLED HOLE THRU WALL 4%Ni = ) SUPRItned Date FOR WIRE CONNECTIONS AND FILLED WITH SILICONE TO PREVENT WATER PENETRATION © 20A 120-277VAC DISCONNECT SWITCH MAIN POWER I 1 J-BOX WITH14+ PRIMARY POWER II r- 120 277VAC GROUNDING WIRE 1 NEUTRAL WIRE DISCONNECT © THREADED NIPPLE AND COUPLING 1-1 SWITCH SECONDARY POWER POWER SUPPLY #10 x 3'h”DRIVE SCREWS 6 MINIMUM THREE(3)PER LETTER 1 OR AS REQUIRED PER FIELD CONDITIONS L.... FLEX(FLEXIBLE 1 1/2" SPACERS REQUIRED CONDUIT)/ LIQUID TIGHT �i t CHANNEL LETTER RETURNS -----.1.4, CONNECTIONS I r CHANNEL CHANNEL CHANNEL COUNTER SUNK SCREWED LE LETTER LETTER TO CLEAR LEXAN ANGLE CLIPS ONE(1)1/4"WEEP HOLE BEHIND LETTER PRIMARY LO(;ATED AT ALL AREAS THAT MAY COLLECT WATER POWER DISCONNECT SWITCH AT FAR LEFT OR RIGHT OF END LETTER "THIS SIGN IS SUITABLE FOR WET LOCATIONS" VERIFY PLACEMENT PRIOR TO FABRICATION LABEL SIGN WITH MINIMUM 1/8"COPY LETTER LAYOUT - PLAN VIEW TYPICAL SECTION DETAIL NOT TO SCALE SCALE: NTS This sign is intended to be installed in accordance with the requirements of Article 600 of the National Electrical Code and/or other Applicable.This includes proper grouding and bonding of the sign. The location of the disconnect switch after installation shall comply iwth Article 600.6(A) (1) of the National Electrical Code. • , SIGNS This sign is intended to be installed In accordance with the requirements of Article 600 of the National Electrical Code and/or other applicable local codes.This includes proper grounding and bonding of the sign. ELECTRICAL ADVERTISING INC JOB LOCATION APPROVED 9437 VALLEY BL., ROSEMEAD, CA 91770 I Sanrio at Westfield Arcadia, #304 TEL: 626-448-1166 FAX: 626-448-1161 400 S Baldwin Ave,Arcadia,CA 91007 1--4gl-o -_naomv �N pc") o`er �_ O z 0 N N .0 5 c=1) N p,,m n.2._co , . , I 1. --I • I 1 . N) \' I C:, i IIr, i I i N 'b , ... , .7...... N • . - I ,