Loading...
HomeMy WebLinkAboutSOLR-20-0452 ' ) a Permit NO $01R720,-045,2_ City of Arcadia, CA . . - �? r i } Development Services Department � � ' '�-� Permit Type Solar ..t,,,..:\ a� 240 West Huntington Drive,Post Office Box 60021 6 , :.° - , _ I Work classification Solar‘iResidential Over 10 KV :::;:,„,..-%,, Arcadia,CA 91066-6021 a � �1,I ipl t J .X-.F'",--' v �. ::-:''''' 'r: N-,'- (626)574-5416 " Permit Status Issued ARCADIA � Issue bate 03/19/2020 Expiration: 09/15/2020 Addr NO. Dir Prefix Street Name '-- - • Street Suffix Unit City,State,Zip Parcel Number 1225 HOLLY AVE Arcadia,CA 91007-6952 5784008023 Contacts CHI P BENNY CHAN Owner LA SOLAR GROUP INC* Contractor '1225 HOLLY AVE ` 16238 RAYMER ST B,VAN NUYS,91406 (626)782-9243 (818)455-9293 974115 Description:ROOF MOUNT PV SYSTEM,SFR, 34 a Valuation: $ 0.00 Tenant e MODULES/MICRO INVERTERS,NEW COMBINER BOX,DERATED MAIN CB 175 AMP. Total Sq Feet: 0.00 Plan Check# Plan# Fees Amount Payments Amount Paid Building Plan Check Fee Residential $50.00 Total Fees $324.72 Distribution Panel $16.48 Cash/Receipt#REC-04125-20 $324.72 Electrical Permit Issuance Fee $47.01 Fire Plan Check Fee Residential $50.00 Amount Due: $0.00 Inverters $77.78 Panels $82.45 Solid Waste Management Fee 2 $1.00 Total: $324.72 1 CALLS FOR INSPECTIONS 011--Z 0 Request for inspection by telephone at 626-574-5450. Leave a message requesting the address,timeframe and what inspection item is needed. �it'/R... 'e-2..aZ r•C 1.G 07k.'.57,-"V This permit/plan review expires by time limitation and becomes null and void if the work authorized by the permit is not commenced within 180 days from the date of issuance or if the permit is not obtained within 180 days from the date of plan submittal.This permit expires and becomes null and void if any work authorized by this permit is suspended or abandoned for 180 consecutive days or if no progressive work has been verified by a City of Arcadia building inspector for a period of 180 consecutive days. i4i5P %‘- ,\I • March 19, 2020 Issued By: Date March 19,2020 Page 1 of 1 OF Alie PERMIT/PLAN REVIEW APPLICATION 0441 j, Development Services Department,240 West Huntington Drive,Post Office Box 60021 mu,,y.,‘" Arcadia, CA 91066-6021, (626) 574-5416,Fax (626) 447-9173 City of Arcadia IIICENSED CONTRACTOR'S DECLARATION WORKERS'COMPENSATION DECLARATION hereby affirm under penalty of perjury that I am licensed under provisions of I ereby affirm under penalty of perjury one of the following: Chapter 9(commencing with Section 7000,of Division 3 of the Business and Professions Code,an' m license is in full force andeffect.effect. ❑'I have and will maintain a certificate of consent to self-insure for workers' License Class' i ei ' License No. Exp. Date 3� 1u, compensation, as provided for by Section 3700 of the Labor Code, for the I . performance of the work for which this permit is issued. Signature of Contractor / J i;, OWNER-BUILDER D • RATIONwri have and will maintain workers'compensation insurance,as required by Section ❑ I hereby affirm under penalty of perjury that I am exempt from the Contractors 3700 of the Labor Code,for the performance of the work for which this permit +.. is issued.My orkers'compensation insurance carrier and policy numbers are: License Law for the following reason(Section 7031.5,Business and Professions �� I r1/71Code.Any city or county which requires a permit to construct,alter,improve, 4 h C ' arrier t 't� demolish,or repair any structure,prior to its issuance,also required the applicantCt D., --I-: -Ia Policy Number for such permit to file a signed statement that he or she is licensed pursuant to the / provisions of the Contractors License Law(Chapter 9(commencing with Section (This section need not be completed if the permit is for one hundred dollars or less) 7000) of Division 3 of the Business and Professions Code)or that he or she is I certify that in the performance of the work for which this permit is issued,I shall exempt there from and the basis for the alleged exemption. Any violation of h❑ Section 7031.5 by any applicant for a permit subjects the applicant to a civil r not employ any person in any manner so as to become subject to the workers' penalty of not more than five hundred dollars($500)): - compensation Laws of California,and agree that if I should become subject to the workers'compensation provisions,�f-See.1 S 0; t e Labor Code,I shall ❑I, as owner of the property, or my employees with wages as their sole forthwith comply with those provislons. compensation,will do the work,and the structure is not intended or offered for ? I 90 �� iel sale(Section 7044,Business and Professions Code:The Contractors License LDate ✓�! W�-/ agailik Signature Law does not apply to an owner of property who builds or improves thereon, or who does such work himself or herself or through his or her own employees,provided that such improvements are not intended or offered for WARNING: Failure to secure Workers'Compensation coverage is unlawful, sale.If,however,the building or improvement is sold within one(1)year of and shall subject an employer to criminal penalties and civil fines up to one completion,the owner-builder will have the burden of proving that he or she hundred thousand dollars($100,000),in addition to the cost of compensation, did not build or improve for the purpose of sale). damages as provided for in Section 3706 of the Labor Code, interest, and attorney's fees. ❑I, as owner of the property, am exclusively contracting with licensed contractors to construct the project(Section 7044,Business and Professions Code:The Contractors License Law does not apply to an owner of property CONSTRUCTION LENDING AGENCY who builds or improves thereon,and who contracts for such projects with a I hereby affirm under penalty of perjury that there is a construction lending agency contractor(s)licensed pursuant to the Contractors License Law). for the performance of the work for which this permit is issued (Section 3097, Civil Code). 0 I am exempt under Section 7044,Business and Professions Code,for this reason: Lender's Name Date Signature Lender's Address IMPORTANT: APPLICATION IS HEREBY MADE TO THE BUILDING OFFICIAL FOR A PERMIT SUBJECT TO THE CONDITIONS AND RESTRICTIONS SET FORTH ON THIS APPLICATION AND THE FOLLOWING: 1. The City's approved plans and permit inspection card must remain on the job site for use by City inspection personnel. 2. Final inspection of the work authorized by this permit is required.A Certificate of Occupancy must be obtained prior to use and occupancy of new buildings and structures. 3. Per South Coast Air Quality Management District(AQMD)regulations,renovation and remodeling work that results in the removal,stripping,or altering of asbestos containing materials requires an asbestos survey and removal prior to disturbing the asbestos.Please contact AQMD at(909)396-2000 for further information. amt � -- )b Title11 3,e�/ i( PRINT NAME I certify that I have read this application and state that the above information is correct and that I am the owner or duly authorized agent of the owner. I agree to comply with all City ordina ces and State Laws relating to building construction. I hereby authorize representatives of the City of Arcadia to enter upon the ab i •-jt • •i•d property for inspection purposes. JP gnatii e— � �P ----- pate,-._.�•- 1_ - • • . . . SOLAR MODULES 34 Panasonic 330 Watt • ALL EXPOSED CONDUIT AND Model#VBHN330SA17E INVERTER MECHANICAL EQUIPMENT INVERTER TYPE: Micro: SHALL BE PAINTED TO MATCH 34 FACTORY-INTEGRATED 111 Enphase IQ7X MICROINVERTERS Model#1Q7X-96-2-US(240V) ROOF AND WALLS MSP (E) 400A Main Service Panel PV Array 3 Pananonic 330 Watt modules With Main breaker Downsized to175A 3 Enphase I07X Microinyorters Tat:20 Deg • AC (N)60A AC Disconnect Azimuth:270 D.. =p 1B1 ELM ECB (N)Enphase Combiner Box MI SSP (E)200A Service Sub Panel PV kray 3 Panasonic 330 Watt modules 3 Etiphase 107X Microinyerters 1r-• JB Junction Box Mk:20 Deg . Azimuth:180 D.. 41. VA. EMT type Conduit — — Fire Setback Line PV kray 8 Panasonic 330 Watt modu 8 Enphase 107X Microlnyede 1111:20 Deg • Athnuth:270... . . • NOTE:A 36-inchwide pathway shall be provided to the emergency escape and rescue opening. PV Array 4 Panasonic 330 Watt modules 4 phe IQ7X Mic All electrical work shall be designed per 2019 Los EnasrolnvertersTilt:20 Deg it_ , Angeles County Electrical Code, 2019 California Electrical Code, and 2019 National Electrical Code and 2019 Building Energy Efficiency Standards. Azimuth:180 De," 110.2 Approval:All electrical equipment shall be labeled, listed, or certified by a Nationally Recognized Testing Laboratory accredited by the United States Occupational Safety Health Administration. . . ) EQUIPMENT ELEVATION Is ' - : -----, nu tin '. '-.--- ttp _ En•hase Combiner Box ..., Ki 4C ;' i 0. il , . . -.t.-41,,N-- t• -a, ;,7,-- ,.. „,.A4C, `111 +. ti4'.'r...^t.4 i 4%. , A 1.• ,-. ,Rt07.! zr- Guest House --i-7:5 `.-.P., -.-t-i•,., -,,P: to E SSP )se. 4.4.* :',"„1:_,,,,w4+,X94,11.`..1.7-', "r”= 0••• n;t OV7:4Nt ''.0 AC disconnect 'at 3• . i . , • 1 NOTE: CONDUIT S . . . . . . . N 7j���� /L I General Notes ) es d wv CONTRACTOR: I ps ip-� 5'-2a - W 1 e4t7 / E LA Solar Group AC under ECB s I �, Gate 5 16238 B Raymer St., .n-d1 I S Van Nuys,CA 91406 —t----S*--, 1B6lik. Phone:(818)373-0077 n PVAraY LIC TYPE:C-46,C-10,C-39 1 I I 16 Panasonic 330 Watt modules 1 16 Enphese n reverters .11-6"1 „ I I - I nn:zo Des LIc#974116 -6 I 1 Azimuth:60 Dam_ iF 3' 1 3 a l Garage Outline . � LASOLAR pA r1=I 1 3' GR OUP 1.. / / 1 3 Lica. + Ara Petrosyan / • . 3 3 `\ (E)SSP 2 I 3. 2 2 [ 3 3 --rr� 2R. 3 — 2 2 3 3 2 )— ` 3. 2 : at /04 \— ' 2 . �.Cit_;n . x' 222 \ / j\ 1'-6n Nillt SITE MAP'& PV LAYOUT C__) . O / �• I No.I( RevldoMaue ) Dae. Designed By: Vahagn Mkrtchyan Project Name and Address /( Built in 1987 Benny Chan 1225 Holly Arcadia, Singe Family Arcadia,CA,91007 House: 3.817 SQ.F -� • PV SYSTEM Lot: 0.47 acres `c,aFeb..,10.2020PV 01 r. •N i \ sem. ` AS INDICATED SCALE D5 BE PAINTED TO MATCH EXISTING SURFACE. ,