HomeMy WebLinkAboutSOLR-20-0452 ' ) a Permit NO $01R720,-045,2_
City of Arcadia, CA . . -
�? r
i } Development Services Department � � ' '�-� Permit Type Solar
..t,,,..:\ a� 240 West Huntington Drive,Post Office Box 60021 6 ,
:.° - , _ I Work classification Solar‘iResidential Over 10 KV
:::;:,„,..-%,, Arcadia,CA 91066-6021 a � �1,I ipl t J .X-.F'",--' v �. ::-:''''' 'r: N-,'-
(626)574-5416 " Permit Status Issued
ARCADIA � Issue bate 03/19/2020 Expiration: 09/15/2020
Addr NO. Dir Prefix Street Name '-- - • Street Suffix Unit City,State,Zip Parcel Number
1225 HOLLY AVE Arcadia,CA 91007-6952 5784008023
Contacts
CHI P BENNY CHAN Owner LA SOLAR GROUP INC* Contractor
'1225 HOLLY AVE ` 16238 RAYMER ST B,VAN NUYS,91406
(626)782-9243 (818)455-9293 974115
Description:ROOF MOUNT PV SYSTEM,SFR, 34 a Valuation: $ 0.00 Tenant e
MODULES/MICRO INVERTERS,NEW COMBINER BOX,DERATED
MAIN CB 175 AMP. Total Sq Feet: 0.00 Plan Check# Plan#
Fees Amount Payments Amount Paid
Building Plan Check Fee Residential $50.00 Total Fees $324.72
Distribution Panel $16.48 Cash/Receipt#REC-04125-20 $324.72
Electrical Permit Issuance Fee $47.01
Fire Plan Check Fee Residential $50.00 Amount Due: $0.00
Inverters $77.78
Panels $82.45
Solid Waste Management Fee 2 $1.00
Total: $324.72
1
CALLS FOR INSPECTIONS
011--Z 0 Request for inspection by telephone at 626-574-5450. Leave a message
requesting the address,timeframe and what inspection item is needed.
�it'/R... 'e-2..aZ r•C 1.G 07k.'.57,-"V
This permit/plan review expires by time limitation and becomes null and
void if the work authorized by the permit is not commenced within 180 days
from the date of issuance or if the permit is not obtained within 180 days
from the date of plan submittal.This permit expires and becomes null and
void if any work authorized by this permit is suspended or abandoned for 180
consecutive days or if no progressive work has been verified by a City of
Arcadia building inspector for a period of 180 consecutive days.
i4i5P
%‘-
,\I
•
March 19, 2020
Issued By: Date
March 19,2020 Page 1 of 1
OF Alie
PERMIT/PLAN REVIEW APPLICATION
0441 j, Development Services Department,240 West Huntington Drive,Post Office Box 60021
mu,,y.,‘" Arcadia, CA 91066-6021, (626) 574-5416,Fax (626) 447-9173
City of
Arcadia
IIICENSED CONTRACTOR'S DECLARATION WORKERS'COMPENSATION DECLARATION
hereby affirm under penalty of perjury that I am licensed under provisions of I ereby affirm under penalty of perjury one of the following:
Chapter 9(commencing with Section 7000,of Division 3 of the Business and
Professions Code,an' m license is in full force andeffect.effect. ❑'I have and will maintain a certificate of consent to self-insure for workers'
License Class' i ei ' License No. Exp. Date 3� 1u, compensation, as provided for by Section 3700 of the Labor Code, for the
I . performance of the work for which this permit is issued.
Signature of Contractor / J i;,
OWNER-BUILDER D • RATIONwri have and will maintain workers'compensation insurance,as required by Section
❑ I hereby affirm under penalty of perjury that I am exempt from the Contractors 3700 of the Labor Code,for the performance of the work for which this permit
+.. is issued.My orkers'compensation insurance carrier and policy numbers are:
License Law for the following reason(Section 7031.5,Business and Professions �� I r1/71Code.Any city or county which requires a permit to construct,alter,improve, 4 h C '
arrier t 't�
demolish,or repair any structure,prior to its issuance,also required the applicantCt D., --I-: -Ia
Policy Number
for such permit to file a signed statement that he or she is licensed pursuant to the /
provisions of the Contractors License Law(Chapter 9(commencing with Section (This section need not be completed if the permit is for one hundred dollars or less)
7000) of Division 3 of the Business and Professions Code)or that he or she is
I certify that in the performance of the work for which this permit is issued,I shall
exempt there from and the basis for the alleged exemption. Any violation of h❑
Section 7031.5 by any applicant for a permit subjects the applicant to a civil r not employ any person in any manner so as to become subject to the workers'
penalty of not more than five hundred dollars($500)): - compensation Laws of California,and agree that if I should become subject to the
workers'compensation provisions,�f-See.1 S 0; t e Labor Code,I shall
❑I, as owner of the property, or my employees with wages as their sole forthwith comply with those provislons.
compensation,will do the work,and the structure is not intended or offered for ? I 90 �� iel
sale(Section 7044,Business and Professions Code:The Contractors License LDate ✓�! W�-/ agailik
Signature
Law does not apply to an owner of property who builds or improves thereon,
or who does such work himself or herself or through his or her own
employees,provided that such improvements are not intended or offered for WARNING: Failure to secure Workers'Compensation coverage is unlawful,
sale.If,however,the building or improvement is sold within one(1)year of and shall subject an employer to criminal penalties and civil fines up to one
completion,the owner-builder will have the burden of proving that he or she hundred thousand dollars($100,000),in addition to the cost of compensation,
did not build or improve for the purpose of sale). damages as provided for in Section 3706 of the Labor Code, interest, and
attorney's fees.
❑I, as owner of the property, am exclusively contracting with licensed
contractors to construct the project(Section 7044,Business and Professions
Code:The Contractors License Law does not apply to an owner of property CONSTRUCTION LENDING AGENCY
who builds or improves thereon,and who contracts for such projects with a I hereby affirm under penalty of perjury that there is a construction lending agency
contractor(s)licensed pursuant to the Contractors License Law). for the performance of the work for which this permit is issued (Section 3097,
Civil Code).
0 I am exempt under Section 7044,Business and Professions Code,for this reason:
Lender's Name
Date Signature Lender's Address
IMPORTANT: APPLICATION IS HEREBY MADE TO THE BUILDING OFFICIAL FOR A PERMIT SUBJECT TO THE CONDITIONS AND
RESTRICTIONS SET FORTH ON THIS APPLICATION AND THE FOLLOWING:
1. The City's approved plans and permit inspection card must remain on the job site for use by City inspection personnel.
2. Final inspection of the work authorized by this permit is required.A Certificate of Occupancy must be obtained prior to use and occupancy of new buildings
and structures.
3. Per South Coast Air Quality Management District(AQMD)regulations,renovation and remodeling work that results in the removal,stripping,or altering
of asbestos containing materials requires an asbestos survey and removal prior to disturbing the asbestos.Please contact AQMD at(909)396-2000 for
further information.
amt � -- )b Title11 3,e�/ i(
PRINT NAME
I certify that I have read this application and state that the above information is correct and that I am the owner or duly authorized agent of the owner.
I agree to comply with all City ordina ces and State Laws relating to building construction. I hereby authorize representatives of the City of
Arcadia to enter upon the ab i •-jt • •i•d property for inspection purposes.
JP
gnatii e— � �P ----- pate,-._.�•- 1_
-
• •
. . .
SOLAR MODULES
34 Panasonic 330 Watt •
ALL EXPOSED CONDUIT AND
Model#VBHN330SA17E
INVERTER MECHANICAL EQUIPMENT
INVERTER TYPE: Micro: SHALL BE PAINTED TO MATCH
34 FACTORY-INTEGRATED
111 Enphase IQ7X MICROINVERTERS
Model#1Q7X-96-2-US(240V) ROOF AND WALLS
MSP (E) 400A Main Service Panel PV Array
3 Pananonic 330 Watt modules
With Main breaker Downsized to175A 3 Enphase I07X Microinyorters
Tat:20 Deg •
AC (N)60A AC Disconnect Azimuth:270 D.. =p
1B1 ELM
ECB (N)Enphase Combiner Box
MI
SSP (E)200A Service Sub Panel PV kray
3 Panasonic 330 Watt modules
3 Etiphase 107X Microinyerters 1r-•
JB Junction Box Mk:20 Deg .
Azimuth:180 D.. 41.
VA.
EMT type Conduit
— — Fire Setback Line PV kray
8 Panasonic 330 Watt modu
8 Enphase 107X Microlnyede
1111:20 Deg
• Athnuth:270... . .
• NOTE:A 36-inchwide pathway
shall be provided to the emergency
escape and rescue opening. PV Array
4 Panasonic 330 Watt modules
4 phe IQ7X Mic
All electrical work shall be designed per 2019 Los EnasrolnvertersTilt:20 Deg
it_ ,
Angeles County Electrical Code, 2019 California
Electrical Code, and 2019 National Electrical Code and
2019 Building Energy Efficiency Standards. Azimuth:180 De,"
110.2 Approval:All electrical equipment shall be
labeled, listed, or certified by a Nationally Recognized
Testing Laboratory accredited by the United States
Occupational Safety Health Administration.
. .
)
EQUIPMENT ELEVATION
Is
' - : -----, nu tin
'. '-.---
ttp
_
En•hase Combiner Box
...,
Ki
4C ;'
i
0.
il , . . -.t.-41,,N-- t• -a, ;,7,-- ,..
„,.A4C, `111
+. ti4'.'r...^t.4 i 4%. ,
A 1.• ,-. ,Rt07.! zr- Guest House
--i-7:5 `.-.P., -.-t-i•,., -,,P:
to E SSP )se.
4.4.* :',"„1:_,,,,w4+,X94,11.`..1.7-', "r”= 0•••
n;t OV7:4Nt ''.0
AC disconnect 'at
3• . i
. ,
•
1
NOTE: CONDUIT S
. . . . .
. .
N
7j���� /L I General Notes )
es
d wv CONTRACTOR:
I ps ip-�
5'-2a - W 1 e4t7 / E LA Solar Group
AC under ECB s I �,
Gate 5 16238 B Raymer St.,
.n-d1 I S Van Nuys,CA 91406
—t----S*--, 1B6lik.
Phone:(818)373-0077
n PVAraY LIC TYPE:C-46,C-10,C-39
1 I I 16 Panasonic 330 Watt modules
1 16 Enphese n reverters
.11-6"1 „ I I - I nn:zo Des LIc#974116
-6 I 1 Azimuth:60 Dam_
iF
3' 1 3 a l Garage Outline . � LASOLAR
pA r1=I 1 3' GR OUP
1.. / / 1 3 Lica. + Ara Petrosyan
/ • . 3 3 `\ (E)SSP
2 I 3.
2 2 [ 3 3 --rr�
2R. 3
— 2 2 3
3
2 )— ` 3.
2 : at /04
\— ' 2 . �.Cit_;n
.
x' 222 \
/
j\ 1'-6n Nillt
SITE MAP'& PV
LAYOUT
C__) . O
/ �• I No.I( RevldoMaue ) Dae.
Designed By:
Vahagn Mkrtchyan
Project Name and Address
/( Built in 1987 Benny Chan
1225 Holly Arcadia,
Singe Family Arcadia,CA,91007
House: 3.817 SQ.F -� •
PV SYSTEM
Lot: 0.47 acres `c,aFeb..,10.2020PV 01
r. •N i \ sem.
`
AS INDICATED
SCALE D5
BE PAINTED TO MATCH EXISTING SURFACE. ,