Loading...
HomeMy WebLinkAboutApproved PlansVICINITY MAP NGUYEN RESIDENCE INTERIOR REMODEL -ADDITION AND BACKYARD 1930 S SANTA ANITA AVEN U E,ARCADIA CA 91006 APPLICABLE CODES: 20 19 CALIFORNIA BUILDING CODE (CBC. 3DIB CALIFORNIA ELECTRICAL CCOE (CECX ID1BCALIFORNIA MECHANICAL CODE (CMC. 2019 CALIFORNIA PLUMBING CODE (CPC. 2019 ENERGY CODE (CA TIRE 24) 2018 CALIFORNIA RESIDENTIAL CODE (DRC. 2019CALRORNIA ENERGY EFFICIENCY CODE (CEEB). 2019 CALIFORNIA FIRE CODE (CFC) 2019 CALIFORNIA GREEN BOWING STANDARDS CODE (CGBSC. AND AS AMENDED BY THE CITY E)HDUSE AREA 2,400 8WOSF ;EIGARAGE AREA 359.48 SF LOT AREA 3.300 SF 57 APN 5]8901101 MUDROOMAGGTW ADDITION BD34 SF CALIFORNIA ROOMAGGITpN 209.00 SE SALIFORNUI ROOM 381.78 BE BALCONY 75.28 SF HIW CEILING AT FOYER 188.Ya BF FLOOR FLaGR ^RFA RAn[12488.00 8W.34.2.031 .1WSY1- LOT COVERAGE y woe► !4a s 4b4, +ybl of INDEX OF DRAWINGS SHEET. Q 1. T TITLE SHEET'UOT PLAN 2. A-1 "STINGBACKYARD 3. M1t 1 PROPOSED BACKYARD 4.A2 EXISTING FLOOR PLANS 5. A2I PROPOSED FIRST FLOOR PLAN 6. A32 PROPOSED SECOND FLOOR PLAN ]. A2.3 PROPOSED ROOF PW! B. A3 ELEVATION5 9. A A ELEVA== SCOPE OF WORK A BUILDING: REMODEL BACKYARD.INTERIOR HOUSE APPROVED DEC 10 2020 planning Services City of Arcadia s't.m is A) Tn C-) x O 0 r SITE PLAN SCALE 1116"=1'-0' LANDWG BTTREE TO BE REMOVEMEE ARBORIST REPORT EXIST. REAR YARD PE'TREETOBE REMOVEMEE AERORISTREPORT (E)CMflHORTREE W TRUNK iIFM. Ai 4.S FROM fl00T TO BE REMOVED (E)LMBT REMFUD TREE TRUNK DAM AT 4.S FROM SO TO =RE ZD w ¢ 381 EPGPAAGE I (E)SINGLE FAMILY JA,t6 SF HOUSE 2,400.00SF SS. IF 21859 S' EXIST, FRONT YARD SANTA ANITA AVENUE x m CID0 m z m m SITE PLAN NOTES 1.SEE GENERAL NOTES DIVISION FOR ADDITIONAL INFORMATION 3.SEPARATE PERMIT IS REQUIRED FOR EACH BUILDING OR STRUCTURE ,I.E FENCE WALLS,RETAINING WALLS,SWiMMING FOOLS/SPAS AND TENNIS COURTS. 4AEFERRED SUBMITTALS TO BE RENEWED BY PROJECT DESIGNER PRIOR TO SUBMITTAL 5.A CAL OSHA PERMIT IS REWIRED FOR EXCAVATIONS DEEPER THAN 5' AND FOR SHORING AND UNDERPINNING ,CONTRACTOR TO PROVIDE A COPY OF OSHA PERMIT. &GENERAL CONTRACTOR SHALL CONTACT DIG ALERT (CALL 811) PRIOR TO ANY DIGGING. TAN APPROVED ENCROACHMENT PERMIT IS REWIRED FOR ALL WORK ACTIVOIES WITHIN THE PUBLIC RIGHT-OF-WAY. B.A CITY ENCROACHMENT IS REWIRED FOR ALL NONSTANDARD PRIVATE IMPROVEMENTS WITHIN THE PUBLIC RIGHT-OF-WAY. 9.A PUBUC WORK DEPARTMENT ENCROACHMENT PERMIT INSPECTION IS REWIRED BEFORE THE BUILDING DEPARTMENT PERMIT ANAL CAN BE ISSUED .AT THE TIME OF PUBLIC WORKS DEPARTMENT INSPECTION . IF ANY OF THE EXISTING PUBLIC IMPROVEMENTS SURROUNDING THE SITE IS DAMAGED ,NEW CONCRETE SIDEWALK ,CURB AND GUTTER ,AND ALLEY/STREET PAVEMENT WILL BE REWIRED AND 1007. PAID BY THE OWNER. SAID DETERMINATON AND THE EXTEND OF THE REPAIR WORK SHALL BE MADE AT THE DISCRETION OF THE PUBLIC WORKS INSPECTOR . 1000NSTRUCTON FENCING IS REWIRED FOR NEW CONSTRUCTION AND FOR ADDIRON PLUS REMODEL PROJECTS EXCENDING 75% OF THE AREA OF PROPOSED STRUCTURE .FENCE HEIGHT TO BE BETWEEN 72° AND 84' HIGH. GENERAL NOTES TYPICAL NOTES GENERAL 1. ALL DETAILS, SECTIONS AND NOTES SHOWN ON THIS DRAWING ARE INTENDED TO BE TYPICAL AN SHALL APPLY TO SIMILAR SITUATIONS ELSEWHERE UNLESS OTHERWISE NOTED, NOTES AND DETAILS ON DRAWINGS TAKE PRECEDENCE OVER THESE GENERAL NOTES AND TYPICAL DETAILS. 2. SEE ARCHITECTURAL DRAWINGS FOR DOORS, WINDOWS, NON-BEARING INTERIOR AND EXTERIOR WALLS, ELEVATIONS, SLOPES, STAIRS, CURBS, DRAINS, DEPRESSIONS, RAILINGS, WATERPROOFING . FINISHES, ETC. 3, CONTRACTOR SHALL VERIFY ALL DIMENSIONS AND CONDITIONS AT THE SITE AND SHALL REPORT ANY DISCREPANCIES TO THE DESIGN PROFESSIONAL. THE CONTRACTOR SHALL BE RESPONSIBLE FOR COORDINATION OF ALL WORK AND MATERIALS INCLUDED THOSE FURNISHED BY THE SUBCONTRACTORS. 4. ALL WORKMANSHIP AND MATERIALS SHALL CONFORM TO THE REQUIREMENTS OF THE GOVERNING BUILDING CODE 5. ALL ASTM DESIGNATIONS SHALL BE AS AMENDED TO DATE UNLESS OTHERWISE NOTED 6. ALL OMISSIONS OR CONFLICTS BETWEEN THE VARIOUS ELEMENTS BROUGHT TO THE ATTENTION OF THE ARCHITECT AND/CR THE DESIGN PROFESSIONAL BEFORE PROCEEDING WITH ANY OF THE WORK INVOLVED. 7, ALL CONCRETE IS DESIGNED BY ULTIMATE STRENGTH DESIGN. 1) CONTRACTOR TO FIELD VERIFY ALL EXISTING DIMENSIONS AND CONDITIONS PRIOR TO CONSTRUCTION AND NOTIFY ARCHITECT OF ANY SPEOAL CONDITIONS OR DISCREPANCIES BEFORE PROCEEDING NTI ANY ADDITIONAL WORK. 2) IN CASE OF DISCREPANCIES OR CONVICTS, NOTIFY DESIGN PROFESSIONAL BEFORE PROCEEDING WITH ANY WORK. 3) DO NOT SCALE DRANNGS - WRITTEN DIMENSIONS TAKE PRECEDENCE. AS 3111 A MS A H Q 040 Zt•tj Za Z Q LL. ILOZ� O,�y 0�4U N y W D W O O an Ap A. AD - GRAPHIC SSKBDS A COLUMNLINEOR INTERORELWATIONNUMBER I GRIDLINE SHEET NUMBER MATCH UNE SHADED PORTION _ �- IS THE SIDE CONSIDERED. O DOORNUMBER y WORK MINT, CONTROL POINT, jQ- ORDANMPOINT. O ON" NUMBER 2 ETNLIomnCATION O KEYNOTE NUMBER ADH EET WHERE DETNLS DRAWN ^ REVISION CLWO ECTIONIDENRFICATON T AROUND REVISION M Wwom H Q 040 Zt•tj Za Z Q LL. ILOZ� O,�y 0�4U N y W D W O O REVISIONS qq •Iannina W9.R<.20 y' m TO REMAIN 4_________ -----o 0 co SANTA ANITA AVENUE REMAIN (E) FLOOR PLAN AND DEMO DEMOLITION KEY NOTES 9CMU WALL TO BE REMOVED s OOL TO REMAIN ftONCRETE DECK TO BE REMOVED oO GRASS TO BE REMOVED AND WATER TO BE CAP -OFF BOND TO BE REMOVED C CONDENSER TO BE REPLACED AND RELOCATED E)GATE TO REMAIN � OL EQUIPMENT ENCLOSURE TO REMAIN )J SP TO BE UPGRADED QCOAST REDWOOD TREE 38" TRUNK DIAM. AT 4.5' FROM ROOT QQ CAMPHOR TREE 21"TRUNK DIAM. AT 4.5' FROM ROOT IVOOD FENCE TO BE REMOVED 'V00L EQUIPMENT TO REMAIN REVISNINS PI=nninn 09.24.40 0 E 8 1 6 R E R A S J ENGINEER DATE 09.26.20 SHEET NO. 2 OF 9 SHEET A-1 a W ~ Z a mac a Z H Z N W p LL. N no 0 Lu REVISNINS PI=nninn 09.24.40 0 E 8 1 6 R E R A S J ENGINEER DATE 09.26.20 SHEET NO. 2 OF 9 SHEET A-1 SANTA ANITA AVENUE Q W ~ (N) PROPOSED BACKYARD � Z _ Q 0 o CONSTRUCTION KEY NOTES Z P t1 Z EPRESSED KITCHEN Lu 14 1% N W V/�W�.ALL 6' HEIGHT FROM (E) GRADE L6 W M O L6 O vaTOOL IN THE POOL O C W <O FOUNTAINS TBD 01-aU POOL ©LOUNGE EPRESSED SITTING AREA AND FIREPIT PA 3 °OTREX DECK AMAIN CONCRETE DECK O6" CURB /y WEATHER FRIENDLY PLANTS AND DECOMPOSITE GRANITE V0�✓' ®NEW CALIFORNIA ROOM (SEE SHEET A-2.1) �.>,®NEW MUDROOM AND PANTRY (SEE SHEET A-2.1) FFM ,ANEW CONCRETE STOOP ANEW SIDEWALK FROM DRIVEWAY O Q ®(E) POOL EQ. ENCLOSURE TO REMAIN ©(E)POOL EQUIP. TO REMAIN EW SECTION OF ASPHALT ,. p Q(E)5' HIGH GATE TO REMAIN EW AC CONDENSER o000 o FOUNTA ELEAVOp pnm(olie SANTA ANITA AVENUE I Plnnnlna 09.26.20 � I I9 TM 09.28.20 SNEET NO. 3 OF 9 1 Q W ~ � Z _ Q 0 Z P t1 Z Lu 14 1% N W p L6 W M O L6 Z O C W 01-aU I Plnnnlna 09.26.20 � I I9 TM 09.28.20 SNEET NO. 3 OF 9 1 EV NOTES NG RAMING TO RECEIVE TESLA ROOFING Z W V Zing., - Z Q V Q Q a'yW0 LL L6 OMWO W a N p> van D Z > 4 O Q W U. Z 0044 0 O .j 19 An planning 02.24.29 4i 1 I SHEET NO.T OF 9 I -2.3 00 PIATESGkMGE 00 ELEVATION KEY NOTES E)CHIMNEY W(E)ROOF FRAMING TO RECEIVE NEW TESLA ROOFING OO (E)PORCH <M)NEW ROOF FRAMING TO RECEIVE TESLA ROOFING ©ADDITION QCALIFORNM ROOM EW WINDOW TO BE MILGARD BLACK ALUMINUM ONEWDOOR ANEW LANDING ®(E)DORMER ®(N)STEPS ZN)POST RONTYARD Q(NrACKYARD )GARAGE DOOR 1111111111111 1111111111111 11111111111111 03 PROPOSED WEST ELEVATION ��lOo ai l-11 PROPOSED SOUTH ELEVATION Z W ZIIIIIIII - Z Q a OC I% L6y0o OoWo W 07.40 0 LU > Q SEAL REVISIONS q Inn ning 09.24. 20 'a SHEET NO.S OF 9 3 1 (N)TRIM AND BEAMS TO MATCH WEST ELEVATION ELEVATION KEY NOTES N Q(E)CHIMNEY EiW OF ROOF ________ _______ Q Q (9(E)ROOF FRAMING TO RECEIVE NEW TESLA ROOFING 0(E)PORCH Q(E)NEW ROOF FRAMING TESLA ROOFING QADDITION ALIFORNIA ROOM e EW WINDOW MILGARD BLACK ALUMINUM m QNEW DOOR ANEW LANDING <D(E)DORMER ®(N)STEPS N)TOP OF ROOF_ ______ a ® N)POST RONT YARD IIIIII ®BACKYARD ®(N)GARAGE DOOR Q (E7FlRST FLOOR_ E WEGMDE PROPOSED EAST ELEVATION )TOP—OF ROOF n �jIN4E�OP OF ROOF A—, it LL_--_________ — ___ Ni 81 Q O E)GECK EL_ E}I3_EGRA PROPOSED NORTH ELEVATION W ~ SEE,4 1 QQ`a Z i Z !�9''/ U 12 LL 00 W"c0,>a 0 y W 0 D 0 0 0 qr. at� cN W Z y0 da 1%j W SEAL REVISIONS FI ..ln9 09 24.20 DATE: 09.25.20 I SHEET NO. 9 OF 9 1 3.1