No preview available
HomeMy WebLinkAboutSOLR-20-1755 City of Arcadia, CA Permit NO.SOLR-20-1755 Development Services Department Permit Type:Solar 240 West Huntington Drive,Post Office Box 60021 Arcadia,CA 91066-6021 Work Classification:Solar-Residential Over 10 KV (626)574-5416 Permit Status:Issued ARC'ADIA Issue Date:10/27/20201 Expiration: 10/27/2021 Addr NO. Dir Prefix Street Name Street Suffix Unit City,State,Zip Parcel Number 1203 HIGHLAND OAKS DR Arcadia,CA 91006-2429 5771018008 Contacts LI HAN Owner NEXUS ENERGY SYSTEMS INC* Contractor 1203 HIGHLAND OAKS,ARCADIA,CA 91006 2810 HARBOR BLVD 201,OXNARD,CA (805)748-5950 359060 - Description:ROOF MOUNT PV SYSTEM, 35 MODULES/MICRO Valuation: $ 0.00 Tenant INVERTERS,COMBINER BOX Total Sq Feet: 0.00 Plan Check# Plan# Fees Amount Payments Amount Paid Building Plan Check Fee Residential $100.00 Total Fees $324.72 Distribution Panel $16.48 Cash/Receipt#REC-05886-20 $324.72 Electrical Permit Issuance Fee $47.01 Inverters $77.78 Amount Due: $0.00 Panels $82.45 Solid Waste Management Fee 2 $1.00 Total: $324.72 0044i'L- I • 1'Zo� CALLS FOR INSPECTIONS Request for inspection by telephone at 626-574-5450. Leave a message requesting the address,timeframe and what inspection item is needed. COMETE This permit/plan review expires by time limitation and becomes null and void if the work authorized by the permit is not commenced within 180 days from the date of issuance or if the permit is not obtained within 180 days from the date of plan submittal.This permit expires and becomes null and void if any work authorized by this permit is suspended or abandoned for 180 consecutive days or if no progressive work has been verified by a City of Arcadia building inspector for a period of 180 consecutive days. October 27, 2020 Issued By: Date October 27,2020 Page 1 of 1 ,FA• .C�'uFORpC'�I 4PERMIT/PLAN REVIEW APPLICATION 3 b' Development Services Department,240 West Huntington Drive,Post Office Box 60021 ooaly o10� Arcadia,CA 91066-6021, (626)574-5416,Fax(626)447-9173 City of Arcadia LICENSED CONTRACTOR'S DECLARATION WORKERS'COMPENSATION DECLARATION 0 I hereby affirm under penalty of perjury that I am licensed under provisions of I hereby affirm under penalty of perjury one of the following: Chapter 9(commencing with Section 7000,of Division 3 of the Business and Professions Code,and my license is in full force and effect. ❑ I have and will maintain a certificate of consent to self-insure for workers' License Class License No. Exp. Date compensation, as provided for by Section 3700 of the Labor Code, for the Signature of Contractor performance of the work for which this permit is issued. OWNER-BUILDER DECLARATION ❑ I have and will maintain workers'compensation insurance,as required by Section ❑ I hereby affirm under penalty of perjury that I am exempt from the Contractors 3700 of the Labor Code,for the performance of the work for which this permit License Law for the following reason(Section 7031.5,Business and Professions is issued.My workers'compensation insurance carrier and policy numbers are: Code.Any city or county which requires a permit to construct,alter,improve, Carrier demolish,or repair any structure,prior to its issuance,also required the applicant Policy Number for such permit to file a signed statement that he or she is licensed pursuant to the provisions of the Contractors License Law(Chapter 9(commencing with Section (This section need not be completed if the permit is for one hundred dollars or less) 7000)of Division 3 of the Business and Professions Code)or that he or she is exempt there from and the basis for the alleged exemption. Any violation of ❑ I certify that in the performance of the work for which this permit is issued,I shall Section 7031.5 by any applicant for a permit subjects the applicant to a civil not employ any person in any manner so as to become subject to the workers' penalty of not more than five hundred dollars($500)): compensation Laws of California,and agree that if I should become subject to the workers'compensation provisions of Section 3700 of the Labor Code,I shall ElI, as owner of the property, or my employees with wages as their sole forthwith comply with those provisions. compensation,will do the work,and the structure is not intended or offered for sale(Section 7044,Business and Professions Code:The Contractors License Date Signature Law does not apply to an owner of property who builds or improves thereon, or who does such work himself or herself or through his or her own employees,provided that such improvements are not intended or offered for WARNING: Failure to secure Workers'Compensation coverage is unlawful, sale.If,however,the building or improvement is sold within one(1)year of and shall subject an employer to criminal penalties and civil fines up to one completion,the owner-builder will have the burden of proving that he or she hundred thousand dollars($100,000),in addition to the cost of compensation, did not build or improve for the purpose of sale). damages as provided for in Section 3706 of the Labor Code, interest, and attorney's fees. 0 I, as owner of the property, am exclusively contracting with licensed contractors to construct the project(Section 7044,Business and Professions Code:The Contractors License Law does not apply to an owner of property CONSTRUCTION LENDING AGENCY who builds or improves thereon,and who contracts for such projects with a I hereby affirm under penalty of perjury that there is a construction lending agency contractor(s)licensed pursuant to the Contractors License Law). for the performance of the work for which this permit is issued (Section 3097, Civil Code). _ ❑ I am exempt under Section 7044,Business and Professions Code,for this reason: Lender's Name Date Signature Lender's Address IMPORTANT: APPLICATION IS HEREBY MADE TO THE BUILDING OFFICIAL FOR A PERMIT SUBJECT TO THE CONDITIONS AND RESTRICTIONS SET FORTH ON THIS APPLICATION AND THE FOLLOWING: 1. The City's approved plans and permit inspection card must remain on the job site for use by City inspection personnel. 2. Final inspection of the work authorized by this permit is required.A Certificate of Occupancy must be obtained prior to use and occupancy of new buildings and structures. 3. Per South Coast Air Quality Management District(AQMD)regulations,renovation and remodeling work that results in the removal,stripping,or altering of asbestos containing materials requires an asbestos survey and removal prior to disturbing the asbestos.Please contact AQMD at(909)396-2000 for further information. Name Title PRINT NAME I certify that I have read this application and state that the above information is correct and that I am the owner or duly authorized agent of the owner. I agree to comply with all City ordinances and State Laws relating to building construction. I hereby authorize representatives of the City of Arcadia to enter upon the above-mentioned property for inspection purposes. Signature Date PERMIT/PLAN REVIEW APPLICATION x Development Services Department, 240 West Huntington Drive, Post Office Box 60021 Arcadia,CA 91066-6021, (626) 574-5416, Fax (626) 447-9173 ONLINE PERMIT/PLAN REVIEW APPLICATION (TTY of A.RCADIA: Job Site Address: 1203 Highland Oaks Dr dLICENSED CONTRACTOR'S DECLARATION WORKERS'COMPENSATION DECLARATION I hereby affirm under penalty of perjury that 1 am licensed under provisions of I hereby affirm under penalty of perjury one of the following: Chapter 9(commencing with Section 7000,of Division 3 of the Business and Professions Code,and my license is in full force and effect. ❑ I have and will maintain a certificate of consent to self-insure for workers' License Class B Li se No.359060 Exp. Date 07/31/2021 compensation, as provided for by Section 3700 of the Labor Code, for the Signature of Contractor G performance of the work for which this permit is issued. 7 OWNER-BUILDER DE LARATI N Vi I have and will maintain workers'compensation insurance,as required by Section 3700 of the Labor Code,for the performance of the work for which this permit D I hereby affirm under penalty of perjury that I am exempt from the Contractors is issued.My workers'compensation insurance carrier and policy numbers are: License Law for the following reason(Section 7031.5, Business and Professions Code.Any city or county which requires a permit to construct, alter,improve, Carrier State Fund demolish,or repair any structure,prior to its issuance.also required the applicant 9032458 for such permit to file a signed statement that he or she is licensed pursuant to the Policy Number provisions of the Contractors License Law(Chapter 9(commencing with Section (This section need not be completed if the permit is for one hundred dollars or less) 7000)of Division 3 of the Business and Professions Code) or that he or she is I certify that in the performance of the work for which this permit is issued.I shall exempt there from and the basis for the alleged exemption. Any violation of ❑ Section 7031.5 by any applicant for a permit subjects the applicant to a civil not employ any person in any manner so as to become subject to the workers' penalty of not more than five hundred dollars($500)): compensation Laws of California.and agree that if I should become subject to the workers'compensation provisions of Section 3700 of the Labor Code,I shall DI, as owner of the property, or my employees with wages as their sole forthwith comply with those provisions. compensation,will do the work,and the structure is not intended or offered for 10/27/20209424144-14247sale(Section 7044, Business and Professions Code:The Contractors LicenseDate Signature Law does not apply to an owner of property who builds or improves thereon, or who does such work himself or herself or through his or her own employees, provided that such improvements are not intended or offered for WARNING: Failure to secure Workers'Compensation coverage is unlawful, sale.If,however,the building or improvement is sold within one(1)year of and shall subject an employer to criminal penalties and civil fines up to one completion,the owner-builder will have the burden of proving that he or she hundred thousand dollars($100,000),in addition to the cost of compensation, did not build or improve for the purpose of sale). damages as provided for in Section 3706 of the Labor Code, interest, and attorney's fees. ❑I, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Section 7044, Business and Professions Code:The Contractors License Law does not apply to an owner of property CONSTRUCTION LENDING AGENCY who builds or improves thereon,and who contracts for such projects with a I hereby affirm under penalty of perjury that there is a construction lending agency contractor(s)licensed pursuant to the Contractors License Law). for the performance of the work for which this permit is issued (Section 3097, Civil Code). ❑ I am exempt under Section 7044,Business and Professions Code,for this reason: Lender's Name Date 10/27/2020 Signature '" ' (9,7 Lender's Address IMPORTANT: APPLICATION IS HERE Iii' .MAD 10 'I HE BUILDING OFFICIAL FOR A PERMIT SUBJECT TO THE CONDITIONS AND RESTRICTIONS SET FORTH ON THIS APPLICATION AND THE FOLLOWING: 1. The City's approved plans and permit inspection card must remain on the job site for use by City inspection personnel. 2. Final inspection of the work authorized by this permit is required.A Certificate of Occupancy must be obtained prior to use and occupancy of new buildings and structures. 3. Per South Coast Air Quality Management District(AQMD)regulations,renovation and remodeling work that results in the removal,stripping,or altering of asbestos containing materials requires an asbestos survey and removal prior to disturbing the asbestos. Please contact AQMD at(909)396-2000 for further information. Name Nexus Energy Systems/Jesse Garay Title Operations Manager PRINT NAME I certify that I have read this application and state that the above information is correct and that I am the owner or duly authorized agent of the owner. I agree to comply with all City ordinances and State Laws relating to building construction. I hereby authorize representatives of the City of Arcadia to enter upon the above-mentioned property for inspection purposes. 10/27/2020 Signature 94444 f€ 4_ 27. Date ifA• 00.3FoRN0,4 410 PERMIT/PLAN REVIEW APPI • two' Development Services Department,240 West Huntington Drive, a00 Arcadia, CA 91066-6021, (626)574-5416,Fax(626) City of Arcadia LICENSED CONTRACTOR'S DECLARATION WORKERS'COMPENSATION DEk I hereby affirm under penalty of perjury that I am licensed under provisions of I hereby affirm under penalty of perjury one of Chapter 9(commencing with Section 7000,of Division 3 of the Business and Professions Code,and my license is in full force and effect. ❑ I have and will maintain a certificate of co_.,cnt to self-insure for workers' License Class License No. Exp. Date compensation, as provided for by Section 3700 of the Labor Code, for the Signature of Contractor performance of the work for which this permit is issued. OWNER-BUILDER DECLARATION ❑ I have and will maintain workers'compensation insurance,as required by Section ❑ I hereby affirm under penalty of perjury that I am exempt from the Contractors 3700 of the Labor Code,for the performance of the work for which this permit License Law for the following reason(Section 7031.5,Business and Professions is issued.My workers'compensation insurance carrier and policy numbers are: Code.Any city or county which requires a permit to construct,alter,improve, Carrier demolish,or repair any structure,prior to its issuance,also required the applicant Policy Number for such permit to file a signed statement that he or she is licensed pursuant to the provisions of the Contractors License Law(Chapter 9(commencing with Section (This section need not be completed if the permit is for one hundred dollars or less) 7000)of Division 3 of the Business and Professions Code)or that he or she is exempt there from and the basis for the alleged exemption. Any violation of ❑ I certify that in the performance of the work for which this permit is issued,I shall Section 7031.5 by any applicant for a permit subjects the applicant to a civil not employ any person in any manner so as to become subject to the workers' penalty of not more than five hundred dollars($500)): compensation Laws of California,and agree that if I should become subject to the workers'compensation provisions of Section 3700 of the Labor Code,I shall ❑I, as owner of the property, or my employees with wages as their sole forthwith comply with those provisions. compensation,will do the work,and the structure is not intended or offered for sale(Section 7044,Business and Professions Code:The Contractors License Date Signature Law does not apply to an owner of property who builds or improves thereon, or who does such work himself or herself or through his or her own employees,provided that such improvements are not intended or offered for WARNING: Failure to secure Workers'Compensation coverage is unlawful, sale.If,however,the building or improvement is sold within one(1)year of and shall subject an employer to criminal penalties and civil fines up to one completion,the owner-builder will have the burden of proving that he or she hundred thousand dollars($100,000),in addition to the cost of compensation, did not build or improve for the purpose of sale). damages as provided for in Section 3706 of the Labor Code, interest, and attorney's fees. ❑I, as owner of the property, am exclusively contracting with licensed contractors to construct the project(Section 7044,Business and Professions Code:The Contractors License Law does not apply to an owner of property CONSTRUCTION LENDING AGENCY who builds or improves thereon,and who contracts for such projects with a I hereby affinn under penalty of perjury that there is a construction lending agency contractor(s)licensed pursuant to the Contractors License Law). for the performance of the work for which this permit is issued (Section 3097, Civil Code). ❑ I am exempt under Section 7044,Business and Professions Code,for this reason: Lender's Name Date Signature Lender's Address IMPORTANT: APPLICATION IS HEREBY MADE TO THE BUILDING OFFICIAL FOR A PERMIT SUBJECT TO THE CONDITIONS AND RESTRICTIONS SET FORTH ON THIS APPLICATION AND THE FOLLOWING: 1. The City's approved plans and permit inspection card must remain on the job site for use by City inspection personnel. 2. Final inspection of the work authorized by this permit is required.A Certificate of Occupancy must be obtained prior to use and occupancy of new buildings and structures. 3. Per South Coast Air Quality Management District(AQMD)regulations,renovation and remodeling work that results in the removal,stripping,or altering of asbestos containing materials requires an asbestos survey and removal prior to disturbing the asbestos.Please contact AQMD at(909)396-2000 for further information. Name Title _ PRINT NAME I certify that I have read this application and state that the above information is correct and that I am the owner or duly authorized agent of the owner. I agree to comply with all City ordinances and State Laws relating to building construction. I hereby authorize representatives of the City of Arcadia to enter upon the above-mentioned property for inspection purposes. Signature Date O n o , m - T m v o o II _ m I O D z m El ,,, I < n m v > z m r Z J ,XI O Z n o m= 0 �m z • _ N•s \\\\\�\\�\\\\\\\\\\\\\��\moo•\�����```\ \\ I z 0c� ' ' S. ' • 4.. •• •• II NI C.- \ 8 (-47. 3: W zl �\\ \\\\\\\\\\\\\\\\\\\\\\ L ,z s•• ,co sI XI M C23 W D ZZ '..• � - O -< D 0 O c < cnnm . . O m o E 7J m m N .. , c(n 0 ;max r 44, m W • CT, G) ;u' ••.4 i • •. 80 SNVO ONVIHDIH CUL - 1 co 13 0 r C w coc Q X LI HAN SYSTEMS 2810 HARBOR BLVD SUITE 201 < @1. N a _ m 1203 HIGHLAND OAKS DR OXNARD,CA 93035 m N m 1 < ARCADIA,CA 91006 CLASS B <l`Nexus Energy co O 0 N PHONE: (626) 822-0721 CA LICENSE#359060 9/18/2020 `,,►� ►� ► oursolarpP tans.com woo y t'om ENGINEERING SOLUTIONS FOR ALL YOUR SOLAR NEEDS Structural Calculations for SOLAR POWER SYSTEM CONNECTION CHECK AT: 1203 HIGHLAND OAKS DR ARCADIA,CA 91006 Job: LI,HAN �(!(/o o� fss /'/b(. j O/ fh t't Prepared For: T s, •/45 O//�// /; S(~t f�'_I NEXUS ENERGY SYSTEMS 6 b�s. //�(, if// ,s.//• / j, cr', ill 2810 HARBOR BLVD f4,, f//i / //��q f//i/(,s (�j/(f��� (%yam of, f /i„ (, ./ // f SUITE 201 / Sri lt�, �(/ /(�• . h/N OXNARD,CA 93035 /ire/'�/�/ ff/,s (Aft if /fh hf "tis.• fry. /i// '!f/, �.i 5//i fd/ '4. (/�j(f //r�(,f rl/ f�P� 411- • (ift.r�r/)J) f(/•• Luis• 41," Design Criteria (/• �/of hs A 1- Code: CALIFORNIA BLDG CODE 2019/ASCE 7-16 .'O(. '' hv// 2-Wind: 110 MPH,Exposure:C hrfrs• t/% 'of 3 -Wood Species: DF-L No.2(SG= 0.5 ) /f('//11,/O4 Notice:Use restrictions of these calculations. The attached Calculations are valid only when bearing original signature hereon. Contractor/Client to verify existing dimensions/conditions prior to construction &solar racking is installed per manufacturer span requirements. The use of these calculations is solely intended for the above mentioned project. ESS/04, se 4(., �G TR4/0 Fy c No. C70784 73 -ItExp.06130/2021 Now S Il 17e OF CA\!F',� 1-844-PV ELITE I info@yoursolarplans.com 3000 E.Birch Street Suite 201 Brea CA 92821 ASCE 29.4.4 Rooftop Solar Panels Parallel to the Roof Surface on Buildings of All Heights and Roof Slopes. Roof Slope 0 = 15 ° Roof Shape Gable Tributary Width s = 4.00 ft Tributary Length I = 2.79 ft Effective Area Ae = 6.52 ft2 Height of Structure h = 25 ft Wind Speed V = 110 mph Exposure Category C Building Width B = 70 ft Building Length L = 85 ft Zone Width a = 7 ft Elevation Height zg = 555 ft Wind Directionality Kd = 0.85 Topography Factor K, = 1.00 Ground Elevation Factor Ke = 0.98 Velocity Pressure Exposure Coefficient KZ = 0.95 Velocity Pressure qZ=0.00256KZKnK.KeV2 = 24.39 psf Solar Array Pressure Equalization Ya = 0.80 Array Edge Factor YE = 1.50 Zone GCp p=g2(GCp)(YE)(Ya) 3 - 3r 3.60 -105.38 3e 3.00 -87.82 2 - 2r 3.00 -87.82 2e - 2n 3.00 -87.82 1 1' proms -i't t't't t1 1111 v.tYw rrl•10%,a 1}t . lead of a1YdeY0.46.1.1egievet•etell70e rera draace3aPee e0if soveremedledge Pese lle70 Oe saeei. alea.. med./.h e.11er Mambos god.esrdlarnrnwale&rnadm He/WY arere e Med &aYs. lel Fdwr.p. No, ..Mlirear Ye4 c O.uyerp.areeefleeeerrrere. c Ersrrl Raw QllarMnU o ® s da 1:NA .'c � 11. WS ai01; ZAA e"'" u.rmrrhee�ler1.. Effective Wind Area A.IN se.wrer5 /Home 900SE 101-S Solar Panel Pressure Epo.aah00 Fedor. (w Enclosed.M Pear.,Each..Bulsrq of Ali N.pl.e .1d. lerylrr eery ce.oe.f.eY esee.lkee.a.r.r.rMame) r r.o a.a r use were pew*leeway*** * aay fr.al ler e.t.a.rapeuary •omos.a.n....t br.aerw pos.rwe4al4c pe.rn Won al w oreleC.a loac Pn...e..enhaun/nrre l,,o1TvaJf...ecwn�e. n o.00ep me..Weer ee1 *4.eee.a.r el the VaM.F aul ..n tee areae!(Ulmer.a M N: cgr..usr..ee1 Pr stew.mw 6.7 tea*NF olihr mrrhar 1,112W.i)Oe Oeaesere.s Oasts N'50 ale.1ee ell(ala..ne.e.re CwM.ne(05.4 Nr e°0.e.e rye e.ne.ra tar sew eueee.-cur Pe.7.e,es LAG SCREW ANALYSIS Loads Wind Pressures qz = -87.82 psf Solar Panel Load QD = 3 psf Panel Length I = 5.575 ft Panel Width b 3.2583 ft Attachment Spacing s = 4 ft Portrait Tributary Area A, = 11.15 ft2 Wind Load Pw=qZ*A, = -979 lbs Dead Load PD=QD*A, = 33.45 lbs Uplift Pa=0.6 PD+0.6 P„, = -567 lbs Landscape Tributary Area A,=b*s = 6.5167 ft2 Wind Load Pw=qz*A, = -572 lbs Dead Load PD=QD*A, = 19.55 lbs Uplift Pa=0.6 PD+0.6 Pw = -332 lbs Lag Screw 5/16"x 5" Specific Gravity of Lumber SG = 0.50 (Douglas Fir-Larch) Diameter of Lag Screw D = 5/16 in Withdraw Design/in 1800*SG312*D3" = 266 lbs/in Depth of Embedment 1, = 2.50 in Total Nominal Withdrawal Value W=W*l, = 665 lbs Load Duration Factor CD = 1.6 Withdrawal Design Value W=W*C D = 1064 lbs Demand Capacity Ratio DCR=Pa/W = 0.53 <1 OK ASCE 30.3.2 Design Wind Pressure Beam/Top Chord Check Roof Slope 0 = 15 ° Roof Shape Gable Tributary Width s = 2.00 ft Tributary Length L = 19.90 ft Effective Area A= L(MAX[s, L/3]) = 100 ft2 Height of Structure h = 25 ft Wind Speed V = 110 mph Exposure Category C Building Width B = 70 ft Building Length L = 85 ft Zone Width a = 7 ft Elevation Height zg = 555 ft Wind Directionality Kd = 0.85 Topography Factor Kt = 1.00 Ground Elevation Factor Ke = 0.98 Velocity Pressure Exposure Coefficient KZ = 0.95 Velocity Pressure qZ=0.00256KZKZ,KdKeV2 = 24.39 psf Internal Pressure Coefficient (GCpi) = -0.18 Zone _ GCp �p=qZ[(GCP)-(Gcpi)] 3 - - 3r 1.80 -48.30 3e 2.25 -59.28 2 - - 2r 2.25 -59.28 2e - - 2n 2.25 -59.28 1 - - Drawer. 1I I -•i- A� Mag'..) .k.a rb.0".e..•v.Y.•Y.a.v.wk. des.N.vJ.P•/■.•a•1o./Orcow l rYpbe tropw••••••••••..............7.".7"i nrr.lr..Tlit them..el &aS ../Ys to I.e•re SiYlalr.rbw•erttr.Yll.Ir ii-•llo••••77.4 k( SMr.J.r.nerd S.tS YrW toed Y.tt • .,#1e,.lo.w even...e•.e kelp 71.11.era..•,to r Vr.44par Ans,Inm 6vrnvW e at.ix, Emend Rerun Cod6.iw.Y .45 _G IX 7. c a 1 IIKIN --1: I •:.17k mu% :: .1 ...mill-,, 14 �:' .-- : Y.a....l..rr.ea5 ar—V.,—..t•5 N..r. I%mud 4Weae.ar.l(:.'nl,1. .n 14Nad.l de.wrn tR•:tne..R•Y.Jlei. IL W�s flow wady pars mass lofted sta wl but sY.alae.lap.b.NJ J I+.oooono ab..e In_pro.r •r owpm. •.'.e.d If%ll1 roof 5&5*..*.te•:Week lreare s.�edo4fi � .e1 IMvo +el lare. • ..se e. kaex.l.Yek.vere•ar14.wma.Irkeow 41 MY.Ail aa.arkJr on..�enale*Tee....e e - cd #arae.•..1JI w iveera Mm 1c e•••k eqe ol.neap. I Wn 301•2111 Cant's.....re 0.117w9 In_..ale:t11 w„1 Ywno w..w..Cattle rot IOC,1 M twos.w PINT..., .R boo..AY•.rrl1Y.bolo 7.•_» Beam/Top Chord Check Lumber: DF-L No.2 Moment Demand #of Attachment per Rafter NA= 4 Span: 1 2 3 4 Eave Orientation j I(ft) pa,(lbs)p (lbs)p„j(lbs) Lenght(ft): 6.07 12.83 0.00 0.00 1.00 1 3.7 33.5 -661 Portrait 2 7.9 33.5 -661 3 9.3 33.5 -661 Portrait Dead Load Roof Material: C-TILE De= 17.00 psf 4 13.4 33.5 -661 Live Load Du= 20 psf Wnd Load p. -59.28 psf Snow Load Qs= 0.00 psf Rafter Spacing s= 24 in Ar(ft) pd(lbs) p„(lbs) p,(lbs) Wnd Load,Portrait Portrait U,= 11.15 33.45 -661 0 Wind Load,Landscape Landscape LJi.x„= 6.5167 19.55 -386 0 Linear Dead Load wd= 34 plf Live Load wLr= 40 plf Start 0 ft Start 14.15 ft End 3 fl End 19.90 ft Snow Load ws= 0 plf Start 0 ft Start 14.15 ft 1500.0 End 3 ft End 19.90 ft 1000.0 500.0 M„Moment D 660 lb-ft 0.0 0.000 .000 10.000 15.000 20.000 25.000 D+Lr 740 lb-ft 500.0 D+S 660 lb-ft -1000.0 0.6D+0.6W 1298 lb-ft -1500.0 D+0.45W+0.75Lr 611 lb-ft D+0.45W+0.75S 611 lb-ft M(x)=R,(x-Lr)-P/(x-11)--2 22 Moment Capacity Framing Member Size 2X8 Lumber Grade: DF-L No.2 CM= 1 C,= 1 C 1.15 CF= 1.2 fb= 900 psi Cu= 1.0 C,= 1 Breadth b= 1.50 in Depth d= 7.25 in Section Modulus S, =bd2/6= 13.1 in' Bending Stress Capacity F0= CM'C,'C,'Crfb= 1242 psi Table 4.3.1 NDS 2015 Co F0'=Cb'FS ASD Load M,'S, DCR 0.9 1118 psi D 602 psi 0.54 OKAY 1.25 1553 psi D+Lr 676 psi 0.44 OKAY 1.15 1428 psi D+S 602 psi 0.42 OKAY 1.6 1987 psi 0.6D+0.6W 1185 psi 0.60 OKAY 1.6 1987 psi D+0.45W+0.75L1 558 psi 0.28 OKAY 1.6 1987 psi D+0.45W+0.755 558 psi 0.28 OKAY Deflection Limit E= 1600 ksi I= 47.63 in' Transient Deflection 0.295 in Transient Deflection Allowed 522 > 180 [OKAY] Total Deflection 0.311 in Total Deflection Allowed 495 > 120 [OKAY] EISMIC WEIGHT COMPARISON/ANALYSIS-(PER CEBC 2019 Part 10 Chapter 5 Section 502.5) PV System Weight Module Model CS1H-325MS Panel Weight Wpanel = 42.3 lbs Number of Panels NpV = 35 Total PV System Weight WpV=Wpanel * NPV = 1481 lbs Existing Roof Weight Roof Weight Qo = 17.0 psf Building Length Lbuild = 85 ft Building Width Wbuild = 70 ft Roof Area Abuild = 5950 ft2 Building Perimeter Pbuild = 310 ft Wall Height ht = 8 ft Wall weight Qwall = 15 psf Interior wall weight Q. = 10 psf Roof Load Wfloor=Abuild*QD = 1E+05 lbs Wall Load Nwall =ht/2*Qwall *Pbuild+Abuild*Qint/; = 48350 lbs Total Story Weight Wbuild=Wfloor+Wwall = 1E+05 lbs Percentage Weight Increase WpV/Wbuild = 0.99% <10% OKAY