HomeMy WebLinkAboutSOLR-20-1677 y.•:� City of Arcadia, CA Permit NO. SOLR-20-1677 Development Services Department Permit Type:Solar 240 West Huntington Drive,Post Office Box 60021 Work Classification:Solar-Residential Arcadia,CA 91066-6021 (626)574-5416 Permit Status:Issued ARCADIA Issue Date: 10/15/2020 Expiration: 10/15/2021 Addr NO. Dir Prefix Street Name Street Suffix Unit City,State,Zip Parcel Number [ 2317 S FOURTH AVE Arcadia,CA 91006-5327 579002500 Contacts YUN CHUAN LIN Owner SUN SOLAR ENERGY SOLUTIONS INC* Contractor 2317 4th,ARCADIA,CA 91006 8803 SCOBEE ST, BAKERSFIELD,CA 93311 (951)285-9828 1065395 Description:ROOF MOUNTED SOLAR SYSTEM 19 MODULES Valuation: $ 0.00 Tenant WITH BUILT IN MICROINVERTERS AND COMBINER BOX Total Sq Feet: 0.00 Plan Check# Plan# Fees Amount Payments Amount Paid Building Plan Check Fee Residential $100.00 Total Fees $324.72 Distribution Panel $16.48 Cash/Receipt#REC-05765-20 $324.72 Electrical Permit Issuance Fee $47.01 Amount Due: $0.00 Inverters $77.78 Panels $82.45 Solid Waste Management Fee 2 $1.00 Total: $324.72 CALLS FOR INSPECTIONS F/k1l4(.. Request for inspection by telephone at 626-574-5450. Leave a message requesting the address,timeframe and what inspection item is needed. This permit/plan review expires by time limitation and becomes null and void if the work authorized by the permit is not commenced within 180 days from the date of issuance or if the permit is not obtained within 180 days from the date of plan submittal.This permit expires and becomes null and void if any work authorized by this permit is suspended or abandoned for 180 consecutive days or if no progressive work has been verified by a City of Arcadia building inspector for a period of 180 consecutive days. COPLE?ED October 15, 2020 Issued By: Date October 15,2020 Page 1 of 1 sVA• . 1_~ PERMIT/PLAN REVIEW APPLICATION �,�' Development Services Department,240 West Huntington Drive,Post Office Box 60021 Arcadia, CA 91066-6021,(626) 574-5416,Fax(626) 447-9173 City of Arcadia LICENSED CONTRACTOR'S DECLARATION WORKERS'COMPENSATION DECLARATION 0 I hereby affirm under penalty of perjury that I am licensed under provisions of I hereby affirm under penalty of perjury one of the following: Chapter 9(commencing with Section 7000,of Division 3 of the Business and Professions Code,and my license is in full force and effect. la I have and will maintain a certificate of consent to self-insure for workers' License Class t✓u G License o.I0 S 4 Exp. Datell-3o— R' compensation, as provided for by Section 3700 of the Labor Code, for the Signature of Contractor performance of the work for which this permit is issued. OWNER-BUILDE DECLARATION 6 have and will maintain workers'compensation insurance,as required by Section ❑ I hereby affirm under penalty of perjury that I am exempt from the Contractors 3700 of the Labor Code,for the performance of the work for which this permit License Law for the following reason(Section 7031.5,Business and Professions is issued. rkerscompensg4on insurance camp and poliy numbers are: Code.Any city or county which requires a permit to construct,alter,improve, Carrier C , `� L0�� demolish,or repair any structure,prior to its issuance,also required the applicant Policy Number I el 1-17 \ C 1 for such permit to file a signed statement that he or she is licensed pursuant to the provisions of the Contractors License Law(Chapter 9(commencing with Section (This section need not be completed if the permit is for one hundred dollars or less) 7000)of Division 3 of the Business and Professions Code)or that he or she is 0 I ce that in the performance of the work for which this tis issued,I shall exempt there from and the basis for the alleged exemption. Any violation of Pew Section 7031.5 by any applicant for a permit subjects the applicant to a civil not employ any person in any manner so as to become subject to the workers' penalty of not more than five hundred dollars($500)): compensation Laws of California,and agree that if I should become subject to the workers'compensation provisions of Section 3700 of the La'.r Code,I shall ❑I, as owner of the property, or my employees with wages as their sole forthwithcomply with those provisions. compensation,will do the work,and the structure is not intended or offered for ate/0/'S Signature ,/% sale(Section 7044,Business and Professions Code:The Contractors License / Law does not apply to an owner of property who builds or improves thereon, tIr or who does such work himself or herself or through his or her own employees,provided that such improvements are not intended or offered for J WARNING: Failure to secure Workers'Compensation coverage is unlawful, sale.If,however,the building or improvement is sold within one(1)year of and shall subject an employer to criminal penalties and civil fines up to one completion,the owner-builder will have the burden of proving that he or she hundred thousand dollars($100,000),in addition to the cost of compensation, did not build or improve for the purpose of sale). damages as provided for in Section 3706 of the Labor Code, interest, and attorney's fees. ❑I, as owner of the property, am exclusively contracting with licensed contractors to construct the project(Section 7044,Business and Professions Code:The Contractors License Law does not apply to an owner of property CONSTRUCTION LENDING AGENCY who builds or improves thereon,and who contracts for such projects with a I hereby affnn under penalty of perjury that there is a construction lending agency contractor(s)licensed pursuant to the Contractors License Law). for the performance of the work for which this permit is issued (Section 3097, Civil Code). 0 I am exempt under Section 7044,Business and Professions Code,for this reason: Lender's Name Date Signature Lender's Address IMPORTANT: APPLICATION IS HEREBY MADE TO THE BUILDING OFFICIAL FOR A PERMIT SUBJECT TO THE CONDITIONS AND RESTRICTIONS SET FORTH ON THIS APPLICATION AND THE FOLLOWING: 1. The City's approved plans and permit inspection card must remain on the job site for use by City inspection personnel. 2. Final inspection of the work authorized by this permit is required.A Certificate of Occupancy must be obtained prior to use and occupancy of new buildings and structures. 3. Per South Coast Air Quality Management District(AQMD)regulations,renovation and remodeling work that results in the removal,stripping,or altering of asbestos containing materials requires an asbestos survey and removal prior to disturbing the asbestos.Please contact AQMD at(909)396-2000 for further information. L / 4� e L �., ( l 5 Title 7Z/ PRINT NAME certify that I have read this application and state that the above information is correct and that I am the owner or duly authorized agent of the owner. agree to comply with all City ordinances State Laws relating to building construction. I hereby authorize representatives of the City of rcadia to enter u!..n the abov -mentio ed rty r inspection purposes. ignature �/ Date U Ill INDEX MSP (E)Main Service Panel PVS (N)PV Sub Panel PVS6 (N)PV Monitoring System JB (N)Junction Box Roof Access 0M ® Solar Module \ O - Solar \ Conduit FMT Conduit MSP '. - Setback \f .63 Total Roof Area:3153 PVS \0f6 Total Module Area:418 PVS6 ',f JB 13.25%of Coverage \ w iii E b \f 270 1� b ■ \Lof6 ieo° \* 0) I . b D \ Q SCALE: 1/8"=1'-0" le b • ■ b D Roof Access ROOF PLAN • ■ b D 4 '�C9•• �� f Solar PV Array 1 e a� \/��'s Projecf Name: - 9- SunPower 415W AC Modules ■ .�e.c, \�f6e Lin Residence ��` �. !� !1 \* Property address: Pitch: 21 Deg �, \ 2317 South 4th Ave Orientation: 270 Deg Arcadia CA 91006 N 0 0 0 0 ❑ \ , / a aa a a CONTRACTOR �e�Oaa°� <6..,, Sun Solar `e54% 0 0 0 0 0 /c6s�r Energy Solutions A ��c' a a a a a s \dc� •Roof access is not located in areas that ,9) Address: require placement of ground ladders over 'ZZ / 4085 E La Palma Ave. exterior wall openings CRC R331.4.1. !dSuite B Anaheim,CA 92807 All electrical work shall be designed per 202OLos \10SunPower415WAC I Licence:#1065395 Angeles County Electrical Code,2019Califomia Solar PV Array 2 Type:#C-46 Electrical Code,and 2017 National Electrical Code Modules and 2019 Building Energy Efficiency Standards. 110.2 Approval:All electrical equipment shall be Pitch: 21 Deg , 1 labeled,listed,or certified by a Nationally Recognized Orientation: 180 Deg S U N P O W E R' Testing Laboratory accredited by the United States Occupational Safety Health Administration. NOTE:A 36-inchwide pathway by Sun Solar shall be provided to the emergency escape and rescue opening. Drawn By: NOTE: Conduit will run through attic SorarPap•rork.00m SOLAR DATE: 10/02/2020 SOLAR 10/5/2020 PAPERWORK Sun Solar Energy Solutions 4085 E La Palma Ave. Suite B Anaheim, CA 92807 Attn.: To Whom It May Concern re: Job Lin Residence: 2317 South 4th Ave, Arcadia CA 91006 The following calculations are for the structural engineering design of the photovoltaic panels and are valid only for the structural info referenced in the stamped plan set. The verification of such info is the responsibility of others. After review, I certify that the roof structure has sufficient structural capacity for the applied PV loads. All PV mounting equipment shall be designed and installed per manufacturer's approved installation specifications. Qp ES SIO,V Solar Paperwork o �R H4K Professional Engineer ��"o`�� ��yycy Support@solarpaperwork.com C 88083 = r" 03/31/22 Design Criteria: OF Code: 2019 California Building Code ASCE 7-16 Live Load: 20 psf Ult Wind Speed: 95 mph Exposure Cat: C Ground Snow: 0 psf 1317 N. San Fernando BI. #343, Burbank, CA 91504 SolarPaperwork.com 1747-333-5991 , Date :10/5/2020 Job Code: Lin Residence 2of6 SOLAR PAPERWORK Structrure Geometry: Mean Roof Height, hn = 23 ft Eave Height, he = 18 ft Buiding Length, L = 60 ft Building Width, B = 40 ft Module Area = 18.2 ft2 Roof Properties: NOTE: Attachments should be installed in a staggered configuration to properly distribute Roof 1 loading. Roof Pitch (deg) = 21 Roofing Type= Flat Tile Sheathing Type= 5/8 OSB Sheathing Wood Species= Doug Fir-Larch#2 Wood Fb (psf) = 129600 Wood Fv(psf) = 25920 Wood E (psf) = 230400000 Wood Lag Withdrawal (lb/in) = 266 Framing Type= 2x8 Rafter Framing OC Spacing(in.) = 24 Section Thickness, b (in.) = 1.50 Section Depth, d (in.) = 7.25 Section Modulus, Sx(in.^3) = 13.14 Beam Span (ft) = 10 Pen Trib Width (ft) = 2.75 Rail Span (ft) = 4.00 CD (Wind) = 1.6 CD(Snow) = 1.15 Cis= 1.15 CM= 1.0 Ct= 1.0 CL= 1.0 CF= 1.2 CfU= 1.0 Ci= 1.0 Cr= 1.15 Mallowable wind (lb-ft) = 2503 317 N.San Fernando BI.#343, Burbank, CA 91504 SolarPaperwork.com 1747-333-5991 Date :10/5/2020 ° Job Code: Lin Residence 3of6 SOLAR PAPERWORK Mallowable_snow(Ib-ft) = 1799 Dead Load: Flat Tile 9.0 5/8 OSB Sheathing 2.0 2x8 Rafter @ 24" OC 1.2 Misc(Insulation etc) 1.0 Total Roof 1 DL 13.2 psf PV DL 3.0 psf Roof 1 Roof Dist DL= 25 M Roof Dist DL= 309 Def Roof Dist DL= 0.0061 PV uni Dist DL= 6 M PV uni Dist DL= 70 Def PV uni Dist DL= 0.0014 Total uni DL= 30 M Total uni DL= 379 Def Total uni DL= 0.0075 Rail Down DL= 8 Rail M DL= 15 Pens Down DL= 31 Pens Side DL= 12 Wind Load: Ultimate Wind Speed = 95 mph Directionality Factor, kd = 0.85 Topographic Factor, kzt= 1.0 Velocity Pressure Exposure Factor, kz= 0.93 Ground Elevation Factor, ke= 1.00 Velocity Pressure, qz= 18.24 317 N.San Fernando BI.#343, Burbank,CA 91504 SolarPaperwork.com 1747-333-5991 \*, Date :10/5/2020 • /,p ik Job Code: Lin Residence oli7 4of6 SOLAR PAPERWORK Roof 1 External Pressure Up,GCp_1 = -1.50 External Pressure Up,GCp_2 = -2.20 External Pressure Up,GCp_3 = -2.30 External Pressure Down, GCp= 0.60 Design Pressure Up, p_i = -30.78 Design Pressure Up, p_2 = -45.15 Design Pressure Up, p_3 = -47.20 Design Pressure Down, p= 16.00 uni_Dist_W_up= -62 M_uni_Dist_W_up= -770 Def_uni_Dist_W_up= -0.0151 uni Dist Wdown = 32 M_uni Dist W down= 400 Def uni Dist Wdown= 0.0079 Module_Up_W1 = -31 Module_Up_W2 = -45 Module_Down_W= 16 Rail_Up_W1= -85 Rail_Up_W2= -124 Rail Down W= 44 Rail_M_Up_W1 = -169 Rail_M_Up_W2 = -248 Rail M Down W= 88 Pens_Up_W1 = -339 Pens_Up_W2 = -497 Pens Down W= 176 Lag Screw Uplift Check(ASD): 5/16" Lag Screw Withdrawl Value= 266 lb/in. Lag Screw Penetration = 2.5 in. Roof1 0.6D+0.6W (Up zl) : 185 lbs < 665 lbs OK 317 N.San Fernando BI.#343, Burbank, CA 91504 SolarPaperwork.com 1747-333-5991 Date :10/5/2020 • Job Code: Lin Residence 5of6 SOLAR PAPERWORK Roof1 0.6D+0.6W(Up z2) : 279 lbs < 665 lbs OK Framing Check(ASD): Roof1 uni 1.0D+0.6W : 619 lb-ft < 2503 lb-ft OK Roof1 uni 1.0D+0.75*[1.0S+0.6W] : 559 lb-ft < 2503 lb-ft OK Roof1 uni 1.0D+ 1.0S : 379 lb-ft < 1799 lb-ft OK Roof1 uni 0.6D+0.6W(Up z1) : 234 lb-ft < 2503 lb-ft OK Seismic Check: Stucco 10.0 psf 2x4 Studs @ 16" 2.0 psf Gypsum 3.0 psf Misc. (Insulation,etc.) 2.0 psf Total Wall DL= 17 psf Total Wall Area = 3600 ftA2 Total Wall W= 61200 lbs Existing Weight Total Roof DL= 13 psf Total Roof Area = 2400 ftA2 Total Roof W= 31791 lbs Existing Weight PV Panel W= 46 lbs Number of Panels= 19 Total PV W= 865 lbs Additional Weight %increase=(Wexisting+Wadditional)/Wexisting = 1% OK The increase in weight as a result of the solar system is less than 10%of the existing structure and therefore no further seismic analysis is required. Limits of Scope of Work and Liability Existing structure is assumed to have been designed and constructed following appropriate codes at time of erection,and assumed to have appropriate permits.The calculations produced are only for the roof framing supporting the proposed PV installation referenced in the stamped planset and were completed according to generally recognized structural analysis standards and procedures, professional engineering and design experience, opinions and judgements. Existing deficiencies which are unknown or were not observable during time of inspection are not included in this scope of work. All PV modules, racking, and mounting equipment shall be designed and installed per manufacturer's approved installation specifications.The Engineer of Record and Solar Paperwork assume no responsibility for misuse or improper installation.This analysis is not stamped for water leakage. Framing was determined based on information in provided plans and/or photos, along with 317 N.San Fernando BI.#343, Burbank, CA 91504 SolarPaperwork.com 1747-333-5991 r i • f' ` Date :10/5/2020 Job Code: Lin Residence 6of6 SOLAR PAPERWORK engineering judgement. Prior to commencement of work,the contractor shall verify the framing sizes, spacings, and spans noted in the stamped plans,calculations, and cert letter(where applicable) and notify the Engineer of Record of any discrepancies prior to starting construction. Contractor shall also verify that there is no damaged framing that was not addressed in stamped plans, calculations, and cert letter(where applicable) and notify the Engineer of Record of any concerns prior to starting construction. Prior to the commencement of work,the contractor shall verify the existing roof and framing conditions. Notify SolarPaperwork and the engineer of record of any Discrepancies prior to starting construction. Prior to the commencement of work,the contractor shall inspect framing for any damage such as water damage, cracked framing,etc. and notify the E.O.R. if any issues are found.These plans/calculations are stamped for structural code compliance of the roof framing supporting the proposed PV installation reference only.These plans/calculations are not stamped for water leakage. PV modules, racking, and attachment components must follow manufacturer guidelines and requirements.Attachments to be installed in a staggered orientation to properly distribute loads. 317 N.San Fernando BI.#343, Burbank, CA 91504 SolarPaperwork.com 1747-333-5991 ,A.4 iFort,.;�$ /C1 -11-1-sitici—a- Ir\_, •t1 � �� f�lOp} . `O � Dalt y ate--� AFFIDAVIT SELF-CERTIFICATION FOR COMPLIANCE OF SMOKE ALARMS AND CARBON MONOXIDE ALARMS Property Address: ' 17 S' 1L4 //recd,6L7 G4 91/006 Permit Number: O�-f - — 1677 Brief Job Description: r10t.dc -) /. jaic/.f?i icf, Number of smoke alarms installed: _ _ Number of carbon monoxide alarms installed: / When alterations, repairs or additions requiring a permit occur, or sleeping rooms are created, Smoke alarms shall be installed in each sleeping room, and outside each separate sleeping area in the immediate vicinity of the bedrooms, and on each additional story of the dwelling, including basements and habitable attics as required by Section R314 of the 2016 California Residential Code (CRC) and California Health and Safety Code Section 13113.7. For dwellings or sleeping units containing fuel burning appliances or having attached garages, carbon monoxide alarms shall be installed outside each separate sleeping area in the immediate vicinity of the bedrooms, and on each additional story of the dwelling, including basements as required by Section R315 of the of the 2016 California Residential Code (CRC). Multi-purpose alarms (combination carbon monoxide and smoke alarms) may be used. All alarms shall comply with requirements for listing and approval by the Office of the State Fire Marshal. http://osfm.fire.ca.qov/licensinglistings/licenselistinq bml searchcotest.php As owner of the above referenced property, I hereby certify that the smoke alarms and carbon monoxide alarms have been installed in accordance with the manufacturer's instructions and in compliance with the code sections referenced above. I declare under penalty of perjury that the foregoing is true and corrects and that this declaration was executed on (Date) _. 1/ -- // - at Arcadia, California. Owner's Name (printed/typed): ja GS 407 Signature of Owner: -�� This affidavit must be returned to the City of Arcadia inspector prior to final inspection SMOKE ALARM AND CARBON MONOXIDE ALARM LOCATIONS Guest Room c i0;,thi oun U li Storage C--- 1 Family Room .--4 Garage FIRST FLOOR PLAN 0= SMOKE ALARM II = CARBON MONOXIDE ALARM L thii. Mslr Bath P, Master Bedroom r Dining Room Kitchen -- Bath 0 C: Wali (; L Closet N `" raoset Closet Family Room ,. Bedroom Bedroom SECOND FLOOR PLAN • =SMOKE ALARM I e CARBON MONOXIDE ALARM