Loading...
HomeMy WebLinkAboutMNEW-18-1958 'fes • City of Arcadia, CA Permit NO. Mnew-18-1958 • Development Services Department Permit Type:Multi-Family New 240 West Huntington Drive,Post Office Box 60021 Arcadia,CA 91066-6021 Work Classification:MF/New-Detached Condominium (626)574-5416 Permit Status:Issued ARCADIA Issue Date: 11/26/2019 Expiration: Addr NO. Dir Prefix Street Name Street Suffix Unit City,State,Zip Parcel Number 2603 DURHAM CT ARCADIA,CA 91006 5788020031 Contacts LENNAR HOMES OF CALIFORNIA* Owner LENNAR Applicant 15131 ALTON PKWY 365,Irvine,CA 92618 (949)349-8215 Description:3 BED,3.5 BATH WITH ATTACHED GARAGE PLAN Valuation: $ 313,646.49 Tenant 2A.PHASE 1 Total Sq Feet: 2.186.00 Plan Check#18-1948 Plan# Fees Amount Payments Amount Paid Building Issuing Fee $47.01 Total Fees $14,443.26 Building Permit Fees $2,700.60 Cash/Receipt#REC-03191-19 $12,944.42 Fire Plan Check $263.31 Cash/Receipt#REC-002765-2018 $1,498.84 Green Building Standard $13.00 Park&Recreation(MFR) $8,153.78 Amount Due: $0.00 Plan Check,Per Hour $1,235.53 Single Family/Condo/Townhome Impact $1,983.00 Fee 4 ---;/4/4.-C. 9-(7-215 Solid Waste Management Fee $6.25 Strong Motion Inst.Program Res $40.78 Total: $14,443.26 CALLS FOR INSPECTIONS Request for inspection by telephone at 626-574-5450. Leave a message requesting the address,timeframe and what inspection item is needed. tOGM BEI This permit/plan review expires by time limitation and becomes null and void if the work authorized by the permit is not commenced within 180 days from the date of issuance or if the permit is not obtained within 180 days from the date of plan submittal.This permit expires and becomes null and void if any work authorized by this permit is suspended or abandoned for 180 consecutive days or if no progressive work has been verified by a City of Arcadia building inspector for a period of 180 consecutive days. November 26, 2019 Issued By: Date November 26,2019 Page 1 of 1 A: 14011-4r. PERMIT/PLAN REVIEW APPLICATION . •4 _ , 44p. Development Services Department,240 West Huntington Drive,Post Office Box 60021 Arcadia, CA 91066-6021,(626) 574-5416,Fax (626)447-9173 City of Arcadia LICENSED CONTRACTOR'S DECLARATION WORKERS'COMPENSATION DECLARATION hereby affirm under penalty of perjury that I am licensed under provisions of I hereby affirm under penalty of perjury one of the following: hapter 9(commencing with Section 7000,of Division 3 of the Business and Professions Cod and my license is in full force and effect. ❑ I have and will maintain a certificate of consent to self-insure for workers' License Class 'cense No. r Exp. Date ' . _- compensation, as provided for by Section 3700 of the Labor Code, for the Signature of Contractor / i // !i -, performance of the work for which this permit is issued. � OWNER-BUILDER DECLARATION ave and will maintain workers'compensation insurance,as required by Section ❑ I hereby affirm under penalty of perjury that I am exempt from the Contractors 3700 of the Labor Code,for the performance of the work for which this permit License Law for the following reason(Section 7031.5,Business and Professions is issued.My workers'compensation insurance carrier and policy numbers are: Code.Any city or county which requires a permit to construct,alter,improve, Carrier demolish,or repair any structure,prior to its issuance,also required the applicant tic/� for such permit to file a signed statement that he or she is licensed pursuant to the Policy Number L/ provisions of the Contractors License Law(Chapter 9(commencing with Section (This section need not be completed if the permit is for one hundred dollars or less) 7000)of Division 3 of the Business and Professions Code)or that he or she is exempt there from and the basis for the alleged exemption. Any violation of ❑ I certify that in the performance of the work for which this permit is issued,I shall Section 7031.5 by any applicant for a permit subjects the applicant to a civil not employ any person in any manner so as to become subject to the workers' penalty of not more than five hundred dollars($500)): compensation Laws of California,and agree that if I should become subject to the workers'compensation provisions of Section 3700 of the Labor Code,I shall ❑I, as owner of the property, or my employees with wages as their sole forthwith comply 'th those provisions. compensation,will do the work,and the structure is not intended or offered for ____Z1)1( sale(Section 7044,Business and Professions Code:The Contractors License Date Signature Law does not apply to an owner of property who builds or improves thereon, or who does such work himself or herself or through his or her own employees,provided that such improvements are not intended or offered for WARNING: Failure to secure Workers'Compensation coverage is unlawful, sale.If,however,the building or improvement is sold within one(1)year of and shall subject an employer to criminal penalties and civil fines up to one completion,the owner-builder will have the burden of proving that he or she hundred thousand dollars($100,000),in addition to the cost of compensation, did not build or improve for the purpose of sale). damages as provided for in Section 3706 of the Labor Code, interest, and attorney's fees. ❑I, as owner of the property, am exclusively contracting with licensed contractors to construct the project(Section 7044,Business and Professions Code:The Contractors License Law does not apply to an owner of property CONSTRUCTION LENDING AGENCY who builds or improves thereon,and who contracts for such projects with a I hereby affirm under penalty of perjury that there is a construction lending agency contractor(s)licensed pursuant to the Contractors License Law). for the performance of the work for which this permit is issued (Section 3097, Civil Code). ❑ I am exempt under Section 7044,Business and Professions Code,for this reason: Lender's Name Date Signature Lender's Address IMPORTANT: APPLICATION IS HEREBY MADE TO THE BUILDING OFFICIAL FOR A PERMIT SUBJECT TO THE CONDITIONS AND RESTRICTIONS SET FORTH ON THIS APPLICATION AND THE FOLLOWING: 1. The City's approved plans and permit inspection card must remain on the job site for use by City inspection personnel. 2. Final inspection of the work authorized by this permit is required.A Certificate of Occupancy must be obtained prior to use and occupancy of new buildings and structures. 3. Per South Coast Air Quality Management District(AQMD)regulations,renovation and remodeling work that results in the removal,stripping,or altering of asbestos containing materials requires an asbestos survey and removal prior to disturbing the asbestos. Please contact AQMD at(909)396-2000 for further information. Name ���� Title �/ ,D __ /t_A PRINT AME I certify that I have read this application and state that the above information is correct and that I am the owner or duly authorized agent of the owner. I agree to comply with all City ordinances and State Laws relating to building construction. I hereby authorize representatives of the City of Arcadia to enter upon the above-mentioned property for inspection purposes. Signature / Date (//t 7/1 5 NOTES Building Inspections Date Insp. Plumbing Inspections Date Insp. 2 4(53 ,44Ai'- 100. Setbacks 210. Under flr./bldg.drain /-(p 2 '� Mfr/ 101. Rough grade 211. Copper underslab 102. Figs.&forms ?-7-ZC3 212. Rough lumbi 9 9 plumbing 103. Pre-slab Z 7-2..p 7,213. Rough gas f ly �� 3-3(-2-o EX1Eka�C S isl�4iG/nGG 104. Floor joists 214. Shower pan 1 A/.0 �.«Ab✓�� r 105. Steel 215. Water heater $2A-2 106. Grout lift 216. Roof drains 107. Shear nailing 217. Building sewer 108. Diaph nailing F-2-2-4. e�•-� 218. Water service 109. Roof nailing 3-1E•2,=. a' - 219. Final gas 6,, -Za 110. Framing ,i•20-ZZ) --- 6 220. Fixtures �+� 111. Occ./Area Sept.Wall 221. Final plumbing ({-2a-Z ii 112. Sound walls 222. Sewer cap/demo. 113. T-bar Ind 114. Insulation-Flr. Pool Inspections 1 Date Insp. 115. Insulation-Wall ia if ` 240. Excavation/steel 116. Insulation-Ceil. 41. Rough plumbing 117. Drywall nailing g-27-20 42. Light shell/bonding 118. Interior lath 4--/9-2.0 43. Underground conduit 119. Exterior lath -/y-Zo • 44. P-trap 120. Finish grade4�` _ X45. Gas line&test `j 121. Final building ./7'2 ; 246. Fence,gates&signs 122. Final demo/lot clear 247. Pool heater 248. Final electric Electrical Inspections Date Insp. 249. Final.lumbin. 150. Power pole 250. Pool cover 151. Sales lot lighting 251. Pool final 152. Under.round conduit 153. Underslab conduit Reroof Inspections 1 Date 1Insp. - 154. UFER ground Z-7-20 -270. Pre-reroof insp. 155. Water ground71. Roof framing 156. Rough electrical g-1y Za 272. Sheathing nailing 157. Fixtures 273. Final reroof 158. G.F.C.I. 159. E..t.bondin. Sign Inspections I Date I Insp. 160. Service panel $-04041' r 0. Setback/overhang 161. Final electric S Za Za 281. Footing 66(( 282. Conduit/wirin. Mechanical Inspections Date Insp. 283. Disconnect 180. Venting/flue 284. Final sign 181. Furnace/A.C. 182. Rouch HVAC -/e/-2.0 "--- •A Miscellaneous Insp. I Date Insp. 183. Fire dampers 290. Fire alarm 184. Furnace compartment 291. Underground supply 185. Combustion air 292. Fire sprinklers 186. Smoke detectors $.-a,- C 293. Monitor system 187. Metal F.P.rough 294. Hood dry chem. 188. Compressor setback 295. Final 189. Commercial hood 190. Duct shaft Sewers&Offsite Insp. I Date Insp. 191. Final mechanical i 'Z6 fIllaillir 300. Lateral(main to P/L) 301. Saddle/Y Block Wall Inspections Date Insp. 302. Gess...)filled 200. Footings 303. Sidewalk 201. Steel/rebar 304. Driveway 202. Grout lift 305. Curb replacement 203. Final wall 306. Trash bin 1 � � \\ �•' : �\ ;. t� lT ttik tilli91.111,0':, 1 , IF ' r. j' � Certificate ofOccupancy p y City of Arcadia j \ Development Services Department—Building Division /�, -:!,,Y3 ) 3' This certificate issued pursuant to the requirements of the �':� // - , California Building Code certifying that at the time of issuance this structure was in compliance with the various ordinances of the City regulating building construction or use. f --.I /7 1 Permit No. 18-1958 , \� i Building Address: 2603 DURHAM CT ARCADIA, CA 91007 . . \ f' Permit Type: MF NEW Effective CBC: 2016 C.R.C. �I Occupancy Code: R-3/U Zone Code: MU / , Final Date: 9-16-2020 f ypc of Construction: TYPE VB SPRINKLERED '?N 1 :, / Owner: LENNAR HOMES OF CALIFORNIA / r ___ _ _ i t Ken eth Fields, 'uilding 0 icial , I \` _, Post in Conspicuous Place i —� 0 • • City of Arcadia, CA Permit NO. MEP-19-2571 Development Services Department Permit Type:MEP 240 West Huntington Drive,Post Office Box 60021 Arcadia,CA 91066-6021 Work Classification:MEP-Residential (626)574-5416 Permit Status:Issued ARCADIA Issue Date:12/27/2019 Expiration: Addr NO. Dir Prefix Street Name Street Suffix Unit City,State,Zip 2603 DURHAM CT ARCADIA, Contacts LENNAR HOMES OF CALIFORNIA* Owner 15131 ALTON PKWY 365,Irvine,CA 92618 (949)349-8215 Description:FOR SF NEW. 125 AMP SERVICE.HVAC SYSTEM PER Valuation: $ 0.00 Tenant APPROVED PLANS.HERS REQUIRED FOR FINAL Total Sq Feet: 0.00 Plan Check H Plan U • Fees Amount Payments Amount Paid Bathtubs/or Combo $13.21 Total Fees $906.87 Bidet $26.42 Cash/Receipt U REC-03471-19 $906.87 Clothes Washer $13.21 Compressor 3-5 Ton(3 to 15 hp) $36.35 Amount Due: $0.00 Dishwasher $13.21 Electrical Permit Issuance Fee $47.01 Furnace or Burner<=100,000 BTU $19.86 �2,i 4'- zc5—?� Garbage Disposal Fee $13.21 Gas System(Outlets) $62.20 Hood Serviced by Mechanical Exhaust $14.96 Kitchen Sink $13.21 CALLS FOR INSPECTIONS Laundry Trays $13.21 Request for inspection by telephone at 626-574-5450. Leave a message Lavatories $105.68 requesting the address,timeframe and what inspection item is needed. Mechanical Permit Issuance Fee $47.01 Motors,Generators<1 hp $8.07 New Residential Accessory Bldg (sq ft $31.22 This permit/plan review expires by time limitation and becomes null and area) void if the work authorized by the permit is not commenced within 180 days New Residential Elect.(sq ft area) $174.88 from the date of issuance or if the permit is not obtained within 180 days Plumbing Permit Issuance Fee $47.01 from the date of plan submittal.This permit expires and becomes null and Residential Services up to 400 amps $16.48 void if any work authorized by this permit is suspended or abandoned for 180 Sewer Connection on Property $33.01 consecutive days or if no progressive work has been verified by a City of Shower $26.42 Arcadia building inspector for a period of 180 consecutive days. Total: $906.87 0 Cele° December 27, 2019 Issued By: Date December 27,2019 Page 1 of 1 % AR �. osoFoRkra PERMIT/PLAN REVIEW APPLICATION * Development Services Department,240 West Huntington Drive,Post Office Box 60021 Arcadia, CA 91066-6021,(626) 574-5416,Fax (626) 447-9173 City of Arcadia LICENSED CONTRACTOR'S DECLARATION WORKERS'COMPENSATION DECLARATION ❑ I hereby affirm under penalty of perjury that I am licensed under provisions of I hereby affirm under penalty of perjury one of the following: Chapter 9(commencing with Section 7000,of Division 3 of the Business and Professions Code,and my license is in full force and effect. ❑ I have and will maintain a certificate of consent to self-insure for workers' License Class License No. Exp. Date compensation, as provided for by Section 3700 of the Labor Code, for the Signature of Contractor performance of the work for which this permit is issued. WNER-BUILDER DECLARATION 0 I have and will maintain workers'compensation insurance,as required by Section 3700 of the Labor Code,for the performance of the work for which this permit ■ I hereby affirm under penalty of perjury that I am exempt from the Contractors is issued.My workers'compens n insurance carrier and policy numbers are: ►' -nse Law for the following reason(Section 7031.5,Business and Professions C..e.Any city or county which requires a permit to construct,alter,improve, Carver _ (-7 demolish,or repair any structure,prior to its issuance,also required the applicant / for such permit to file a signed statement that he or she is licensed pursuant to the Policy Number provisions of the Contractors License Law(Chapter 9(commencing with Section (This section need not be completed if the permit is for one hundred dollars or less) 7000)of Division 3 of the Business and Professions Code)or that he or she is exempt there from and the basis for the alleged exemption. Any violation of 0 I certify that in the performance of the work for which this permit is issued,I shall Section 7031.5 by any applicant for a permit subjects the applicant to a civil not employ any person in any manner so as to become subject to the workers' penalty of not more than five hundred dollars($500)): compensation Laws of California,and agree that if I should become subject to the workers'compensation provisions of Section 3700 of the Labor Code,I shall ❑I, as owner of the property, or my employees with wages as their sole forthwith compl wr ttSignature s hose provision compensation,will do the work,and the structure is not intended or offered for Date / 7 // / sale(Section 7044,Business and Professions Code:The Contractors License Law does not apply to an owner of property who builds or improves thereon, or who does such work himself or herself or through his or her own employees,provided that such improvements are not intended or offered for WARNING: Failure to secure Workers'Compensation coverage is unlawful, sale.If,however,the building or improvement is sold within one(1)year of and shall subject an employer to criminal penalties and civil fines up to one completion,the owner-builder will have the burden of proving that he or she hundred thousand dollars($100,000),in addition to the cost of compensation, did not build or improve for the purpose of sale). damages as provided for in Section 3706 of the Labor Code, interest, and attorney's fees. O I, as owner of the property, am exclusively contracting with licensed contractors to construct the project(Section 7044,Business and Professions Code:The Contractors License Law does not apply to an owner of property CONSTRUCTION LENDING AGENCY who builds or improves thereon,and who contracts for such projects with a I hereby affirm under penalty of perjury that there is a construction lending agency contractor(s)licensed pursuant to the Contractors License Law). for the performance of the work for which this permit is issued (Section 3097, Civil Code). ❑ I am exempt under Section 7044,Business and Professions Code,for this reason: Lender's Name Date f47// Signature Lender's Address IMPORTANT: APPLICATION IS HEREBY MADE TO THE BUILDING OFFICIAL FOR A PERMIT SUBJECT TO THE CONDITIONS AND RESTRICTIONS SET FORTH ON THIS APPLICATION AND THE FOLLOWING: 1. The City's approved plans and permit inspection card must remain on the job site for use by City inspection personnel. 2. Final inspection of the work authorized by this permit is required.A Certificate of Occupancy must be obtained prior to use and occupancy of new buildings and structures. 3. Per South Coast Air Quality Management District(AQMD)regulations,renovation and remodeling work that results in the removal,stripping,or altering of asbestos containing materials requires an asbestos survey and removal prior to disturbing the asbestos.Please contact AQMD at(909)396-2000 for further information. N... Title Pec6p=e-r- /'l G1,? PRINT NAME I certify that I have read this application and state that the above information is correct and that I am the owner or duly authorized agent of the owner. I agree to comply with all City ordinances and State Laws relating to building construction. I hereby authorize representatives of the City of Arcadia to enter upon the above-mentioned property for inspection purposes. Signature /' v ' Date '1//5 ption 04 one CONSULTING ENGINE/:R. PAGE 1 OF I STRUCTURAL OBSERVATION REPORT CITY of ARCADIA THIS REPORT INCLUDES ALL CONSTRUCTION WORK THROUGH THE: March 30, 2020 PROJECT "Essex"-SFD OPTION ONE J.N. 0918-2286 LOCATION , Arcadia,California BLDG.PERMIT NUMBER Mnew-18-1958 OWNER Lennar Homes LOCATION/DIVISION Coastal ARCHITECT Angeleno ARCHITECT J.N. 1704 STRUCT.OBS.OF RECORD . Ilia Sarad,P.E.,S.E.,S.E.C.B. LIC.OR REGISTRATION No. S-3855 STRUCTURAL OBSERVER Erik Torres,E.I.T. LIC.OR REGISTRATION No. . OBSERVED STRUCTURAL ELEMENTS&THEIR CONNECTIONS: LOT(S)&PHASE OBSERVED: Interior and Exterior General Framing;i.e.,roof trusses,roof sheathing, Phase:1B. Tract:77121 shear elements,holdowns,floor sheathing,floor trusses,beams,headers,and HS#4,Plan 2A general hardware. 2603 Durham Court Arcadia,California 91007 OBSERVED DEFICIENCIES: (ATTACH ADDITIONAL PAGES IF NECESSARY) Initial/Completion Date The deficiencies noted during the observation visit have been corrected and/or installed by a collaborated effort of the foreman and project superintendent. E.T. 03/30/20 Construction Stage: HVAC x❑Electrical Ei Plumbing ❑Double Sided ri Plywood Cg Deck Option r-Guard N/A Shear Walls Lids) Rails Note:When box is checked,it indicates that construction stage is in progress,and it has not yet been completed at the time of observation was conducted EX STRUCTURAL SYSTEM WAS VISUALLY OBSERVED TO BE IN GENERAL CONFORMANCE WITH THE APPROVED PLANS STRUCTURAL DEFICIENCIES ARE OF A MINOR NATURE&MAY BE REVIEWED BY CITY BLDG INSPECTOR FOR COMPLIANCE I DECLARE THAT THE FOLLOWING STATEMENTS ARE TRUE TO THE BEST OF MY KNOWLEDGE AND BELIEF 1. I AM THE REGISTERED ENGINEER WHO HAS RESPONSIBLE CHARGE FOR THE STRUCTURAL OBSERVATION. (iIOF ESS/ 6444 2. I,OR ANOTHER QUALIFIED-CHARGE OBSERVER WHO I HAVE DESIGNATED Q ABOVE AND IS UNDER MY RESPONSIBLE CHARGE,HAS PERFORMED THE 43S5X 3• S4pegoey� REQUIRED SITE VISITS AT EACH SIGNIFICANT CONSTRUCTION STAGE TO VERIFY IF THE STRUCTURE IS IN GENERAL CONFORMANCE WITH THE V APPROVED PLANS AND SPECIFICATIONS. NO. S 3855 3. ALL DEFICIENCIES,WHICH I DOCUMENTED,HAVE BEEN CORRECTED UNLESS OTHERWISE INDICATED ABOVE. Exp. 3/31/2022 '*' 4. ALL OBSERVED DEFICIENCIES SHALL BE CORRECTED AND APPROVED BY THE >, OBSERVER PRIOR TO FINAL ACCEPTANCE OF THE STRUCTURAL SYSTEMS BY `�q RUCT k) THE BUILDING DEPARTMENT. F OF CAL\F 5. THIS REPORT IS PROVIDED TO THE OWNER AS A PART OF THE OWNERS OVERALL CONSTRUCTION QUALITY CONTROL PROGRAM. March 30,2020 6. OPTION ONE HAS PROVIDED STRUCTURAL OBSERVATION IN ACCORDANCE WITH THE SEAOC REC•pp MENDED GUI• LINES FOR THE PRACTICE OF STAMP OF ENGINEER-OF-RECORD STRUCTURAL ENGIN .,,'rt.:•11!;1 I SIGNED BY: �/'.•''�''I� ,oArnMarch 30,2020 Ilia 5ar:i1, P.E., . . .E.C... STRUCTURAL OBSERVAT I N DOE'NOT WAIVE THE REQUIREMENTS FOR INSPECTIONS BY CITY BUILDING INSPECTORS. ALL WORK MUS COMP Y WITH THE APPROVED PLANS AND APPLICABLE STATE&LOCAL CODES. 2286SOR_frmg_HS4_P2A Option One Tel 714.556.1916 Consulting Engineers 2755 Bristol Street, Suite 100, Costa Mesa, Ca. 92626 Fax 714.556.1952 .tom - - ., ' ' ''tptian one PAGE 1 OF 1 STRUCTURAL OBSERVATION REPORT LENNAR HOMES, CA THIS REPORT INCLUDES ALL CONSTRUCTION WORK THROUGH THE: February 6, 2020 PROJECT "Essex"-SFD OPTION ONE J.N. 0918-2286 LOCATION Arcadia,California BLDG.PERMIT NUMBER Mnew-18-1958 OWNER Lennar Homes LOCATION/DIVISION Coastal ARCHITECT Angeleno ARCHITECT J.N. 1704 STRUCT.OBS.OF RECORD Ilia Sarad,P.E.,S.E.,S.E.C.B. LIC.OR REGISTRATION No. S-3855 STRUCTURAL OBSERVER Erik Torres LIC.OR REGISTRATION No. , OBSERVED STRUCTURAL ELEMENTS&THEIR CONNECTIONS: LOT(S)&PHASE OBSERVED: Conventional Foundation System;i.e..anchor bolts,holdown bolts&straps, Phase: 113. Tract: 77121 post bases,Strong-Wall/Hardy Frame anchor bolts,slab size/reinforcement and HS#4,Plan 2A footing&pad size/reinforcement(NOTE:monolithic pour system). 2603 Durham Court Arcadia,California 91007 OBSERVED DEFICIENCIES: (ATTACH ADDITIONAL PAGES IF NECESSARY) Initial/Completion Date The deficiencies noted during the observation visit have been corrected and/or installed by a collaborated effort of the foreman and project superintendent. E.T. 02/06/20 Construction Stage: ❑ ❑ ❑ Double Sided Plywood Gig Guard HVAC Electrical Plumbing ❑ Deck Option ❑ N/A Shear Walls Lid(s) Rails Note:When box is checked,it indicates that construction stage is in progress,and it has not yet been completed at the time of observation was conducted EX STRUCTURAL SYSTEM WAS VISUALLY OBSERVED TO BE IN GENERAL CONFORMANCE WITH THE APPROVED PLANS 0 STRUCTURAL DEFICIENCIES ARE OF A MINOR NATURE&MAY BE REVIEWED BY CITY BLDG INSPECTOR FOR COMPLIANCE I DECLARE THAT THE FOLLOWING STATEMENTS ARE TRUE TO THE BEST OF MY KNOWLEDGE AND BELIEF I. I AM THE REGISTERED ENGINEER WHO HAS RESPONSIBLE CHARGE FOR THE STRUCTURAL OBSERVATION. ROFESS/0 2. 1,OR ANOTHER QUALIFIED-CHARGE OBSERVER WHO I HAVE DESIGNATED O Q k4� ABOVE AND IS UNDER MY RESPONSIBLE CHARGE,HAS PERFORMED THE ... ,q, B. S4,p, e„,_ REQUIRED SITE VISITS AT EACH SIGNIFICANT CONSTRUCTION STAGE TO VERIFY IF THE STRUCTURE IS IN GENERAL CONFORMANCE WITH THEc.y yy APPROVED PLANS AND SPECIFICATIONS. Lo rrt N0. S 3855 3. ALL DEFICIENCIES,WHICH I DOCUMENTED,HAVE BEEN CORRECTED UNLESS OTHERWISE INDICATED ABOVE. *� Exp. p. 3/31/2020 P 4. ALL OBSERVED DEFICIENCIES SHALL BE CORRECTED AND APPROVED BY THE OBSERVER PRIOR TO FINAL ACCEPTANCE OF THE STRUCTURAL SYSTEMS BY �,�r�/t'(/C T 0RP THE BUILDING DEPARTMENT. OF cp,L1F 5. THIS REPORT IS PROVIDED TO THE OWNER AS A PART OF THE OWNERS OVERALL CONSTRUCTION QUALITY CONTROL PROGRAM. February 6,2020 6. OPTION ONE HAS PROVIDED STRUCTURAL OBSERVATION IN ACCORDANCE WITH THE SEAOC RECO W ENDED GUIDELINES FOR THE PRACTICE OF STAMP OF ENGINEER-OF-RECORD STRUCTURAL.ENGINEEV 1k C', IFOr'�: IA. SIGNED BY: Admi ,101_, February 6,2020 Ilia Sar. P.E.,5.E S.E.C.%. STRUCTURAL OBSERVAT ON DOE.NOT WAIVE THE REQUIREMENTS FOR INSPECTIONS BY CITY BUILDING INSPECTORS. ALL WORK MU` CO )'LY WITH THE APPROVED PLANS AND APPLICABLE STATE&LOCAL CODES. 228650R_Foundation_H S4_P2A.xls Option One Tel 714.556.1916 Consulting Engineers 2755 Bristol Street,Suite 100,Costa Mesa,Ca.92626 Fax 714.556.1952 . City of Arcadia, CA Permit NO. SOLR-20-0464 Development Services Department Permit Type:Solar 240 West Huntington Drive,Post Office Box 60021 Arcadia,CA 91066-6021 Work Classification:Solar-Residential (626)574-5416 Permit Status:Issued ARCADIA Issue Date:04/15/2020 Expiration: 10/12/2020 Addr NO. Dir Prefix Street Name Street Suffix Unit City,State,Zip Parcel Number 2603 DURHAM ARCADIA, CA 91006 5788020031 �., Contacts LENNAR HOMES OF CALIFORNIA* Contractor 15131 ALTON PKWY 365,Irvine,CA 92618 (949)349-8215 728102 Description:ROOF MOUNTED SOLAR SYSTEM 9Valuation: $ 0.00 Tenant MODULES/MICROINVERTERS SYSTEM SIZE 2.88 KW Total Sq Feet: 0.00 Plan Check#20-460 Plan# Fees Amount Payments Amount Paid Building Plan Check Fee Residential $50.00 Total Fees $308.24 Electrical Permit Issuance Fee $47.01 Cash/Receipt#REC-04277-20 $308.24 Fire Plan Check Fee Residential $50.00 Inverters $77.78 Amount Due: $0.00 Panels $82.45 Solid Waste Management Fee 2 $1.00 Total: $308.24 1 D 2-0 ?n,rie. sL�,TwG �j CALLS FOR INSPECTIONS le fe0 Request for inspection by telephone at 626-574-5450. Leave a message requesting the address,timeframe and what inspection item is needed. g—7 Z—2.4) c This permit/plan review expires by time limitation and becomes null and void if the work authorized by the permit is not commenced within 180 days from the date of issuance or if the permit is not obtained within 180 days from the date of plan submittal.This permit expires and becomes null and void if any work authorized by this permit is suspended or abandoned for 180 consecutive days or if no progressive work has been verified by a City of Arcadia building inspector for a period of 180 consecutive days. April 15, 2020 Issued By: Date April 15,2020 Page 1 of 1 AR G�,,IFO,��'ice, • 4Pow k PERMIT/PLAN REVIEW APPLICATION' E¢I<V Development Services Department,240 West Huntington Drive,Post Office Box 60021 • .r°cam Arcadia, CA 91066-6021, (626) 574-5416,Fax (626)447-9173 City of Arcadia LICENSED CONTRACTOR'S DECLARATION WORKERS'COMPENSATION DECLARATION ❑ I hereby affirm under penalty of perjury that I am licensed under provisions of I hereby affirm under penalty of perjury one of the following: Chapter 9(commencing with Section 7000,of Division 3 of the Business and Professions Code,and my license is in full force and effect. ❑ I have and will maintain a certificate of consent to self-insure for workers' License Class License No. Exp. Date compensation, as provided for by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. Signature of Contractor OWNER-BUILDER DECLARATION ❑ I have and will maintain workers'compensation insurance,as required by Section 0 I hereby affirm under penalty of perjury that I am exempt from the Contractors 3700 of the Labor Code,for the performance of the work for which this permit License Law for the following reason(Section 7031.5,Business and Professions is issued.My workers'compensation insurance carrier and policy numbers are: Code.Any city or county which requires a permit to construct,alter,improve, Carrier demolish,or repair any structure,prior to its issuance,also required the applicant for such permit to file a signed statement that he or she is licensed pursuant to the Policy Number provisions of the Contractors License Law(Chapter 9(commencing with Section (This section need not be completed if the permit is for one hundred dollars or less) 7000)of Division 3 of the Business and Professions Code)or that he or she is exempt there from and the basis for the alleged exemption. Any violation of 0 I certify that in the performance of the work for which this permit is issued,I shall Section 7031.5 by any applicant for a permit subjects the applicant to a civil not employ any person in any manner so as to become subject to the workers' penalty of not more than five hundred dollars($500)): compensation Laws of California,and agree that if I should become subject to the workers'compensation provisions of Section 3700 of the Labor Code,I shall ❑I, as owner of the property, or my employees with wages as their sole forthwith comply with those provisions. compensation,will do the work,and the structure is not intended or offered for sale(Section 7044,Business and Professions Code:The Contractors License Date Signature Law does not apply to an owner of property who builds or improves thereon, or who does such work himself or herself or through his or her own employees,provided that such improvements are not intended or offered for WARNING: Failure to secure Workers'Compensation coverage is unlawful, sale.If,however,the building or improvement is sold within one(1)year of and shall subject an employer to criminal penalties and civil fines up to one completion,the owner-builder will have the burden of proving that he or she hundred thousand dollars($100,000),in addition to the cost of compensation, did not build or improve for the purpose of sale). damages as provided for in Section 3706 of the Labor Code, interest, and attorney's fees. ❑I, as owner of the property, am exclusively contracting with licensed contractors to construct the project(Section 7044,Business and Professions Code:The Contractors License Law does not apply to an owner of property CONSTRUCTION LENDING AGENCY who builds or improves thereon,and who contracts for such projects with a I hereby affirm under penalty of perjury that there is a construction lending agency contractor(s)licensed pursuant to the Contractors License Law). for the performance of the work for which this permit is issued (Section 3097, Civil Code). ❑ I am exempt under Section 7044,Business and Professions Code,for this reason: Lender's Name Date Signature Lender's Address - IMPORTANT: APPLICATION IS HEREBY MADE TO THE BUILDING OFFICIAL FOR A PERMIT SUBJECT TO THE CONDITIONS AND RESTRICTIONS SET FORTH ON THIS APPLICATION AND THE FOLLOWING: 1. The City's approved plans and permit inspection card must remain on the job site for use by City inspection personnel. 2. Final inspection of the work authorized by this permit is required.A Certificate of Occupancy must be obtained prior to use and occupancy of new buildings and structures. 3. Per South Coast Air Quality Management District(AQMD)regulations,renovation and remodeling work that results in the removal,stripping,or altering of asbestos containing materials requires an asbestos survey and removal prior to disturbing the asbestos.Please contact AQMD at(909)396-2000 for further information. Name Title PRINT NAME I certify that I have read this application and state that the above information is correct and that I am the owner or duly authorized agent of the owner. I agree to comply with all City ordinances and State Laws relating to building construction. I hereby authorize representatives of the City of Arcadia to enter upon the above-mentioned property for inspection purposes. Signature Date PERMIT/PLAN REVIEW APPLICATION Development Services Department, 240 West Huntington Drive, Post Office Box 60021 1 • Arcadia,CA 91066-6021, (626) 574.5416, Fax (626) 447-9173 ONLINE PERMIT/PLAN REVIEW APPLICATION t ii u1 AItC'ADIA Job Site Address: 2( D3 ,Qerkifin LICENSED CONTRACTOR'S DECLARATION WORKERS'COMPENSATION DECLARATION MI hereby affirm under penalty of perjury that I am licensed under provisions of I hereby affirm under penalty of perjury one of the following: Chapter 9(commencing with Section 7000.of Division 3 of the Business and Professions Code,and my license is in full force and effect 0 I have and will maintain a certificate of consent to self-insure for workers' License Class _Lt . /xp Date compensation, as provided for by Section 3700 of the Labor Code, for the Signature of Contractorperformance of the work for which this permit is issued OWNER-BUILDER DECLARATION ra, I have and will maintain workers'compensation insurance,as required by Section 11 I hereby affirm under penalty of perjury that I am exempt from the Contractors 3700 of the Labor Code.for the performance of the work for which this permit License Law for the following reason(Section 7031.3,Business and Professions is issued My workers'compensation insurance carrier and policy numbers are: Code.Any city or county which requires a permit to construct. alter,improve. Carrier demolish,or repair any structure,prior to its issuance.also required the applicant /_ ( 1 for such permit to file a signed statement that he or she is licensed pursuant to the Policy Number provisions of the Contractors License Law(Chapter 9(commencing with Section (This section need not be completed if the permit is for one hundred dollars orless) 7000)of Division 3 of the Business and Professions Code)or that he or she is exempt there from and the basis for the alleged exemption. Any violation of c3I certify that in the performance of the work for which this permit is issued.I shall Section 70313 by any applicant for a permit subjects the applicant to a civil not employ any person in any manner so as to become subject to the workers' penalty of not more than five hundred dollars(5300)). compensation Laws of California,and agree that if I should become subject to the workers'compensation provisions of Section 3700 of the Labor Code.I shall I, as owner of the property, or my•employees with wages as their sole forthwith comply with those provisions compensation,will do the work,and the structure is not intended or offered for sale(Section 7044, Business and Professions Code:The Contractors License Date Signature Law does not apply to an owner of property who builds or improves thereon. or who does such work himself or herself or through his or her own employees, provided that such improvements are not intended or offered for WARNING. Failure to secure Workers'Compensation coverage is unlawful. sale. If,however.the building or improvement is sold within one(I)year of and shall subject an employer to criminal penalties and civil fines up to one completion.the owner-builder will have the burden of proving that he or she hundred thousand dollars(5100,000),in addition to the cost of compensation, did not build or improve for the purpose of sale). damages as provided for in Section 3706 of the Labor Code, interest, and attorney's fees ❑I. as owner of the property, am exclusively contracting with licensed contractors to construct the project (Section 7044,Business and Professions Code:The Contractors License Law does not apply to an owner of property CONSTRUCTION LENDING AGENCY who builds or improves thereon,and who contracts for such projects with a I hereby affirm under penalty of perjury that there is a construction lending agency contractor(s)licensed pursuant to the Contractors License Law). for the performance of the work for which this pennit is issued (Section 3097. Civil Code). c3I am exempt under Section 7044,Business and Professions Code.for this reason. Lender's Name _ Date Signature Lender's Address,.___ 1\11'Ok1':1NT: \1'I'LI('►11UN IS DEW B1' \L\s)I` TO fill. lit WHIM; ()FIi( L.I fork .\ I'f:R\III st 15.11 ('I III I III (l)\1)IllON% SND RES SEA 1:014 Ell tl\TlllS i'I'I ICA 11(IN \\11 TIIE_11)1 1 (ASI\(,: I. The City's approved plans and permit inspection card must remain on the job site for use by City inspection personnel. 2. Final inspection of the work authorized by this permit is required A Certificate of Occupancy must be obtained prior to use and occupancy of new buildings and structures 3 Per South Coast Air Quality Management District (AQMD)regulations,renovation and remodeling work that results in the removal,stripping,or altering of asbestos containing materials requires an asbestos survey and removal prior to disturbing the asbestos Please contact AQMD at(909)396-2000 for further information. Name Title PRINT NAME I certify that I have read this application and state that the above information is correct and that I am the owner or duly authorized agent of the owner. I agree to comply with all City ordinances and State Laws relating to building construction. I hereby authorize representatives of the City of Arcadia to enter upon the above-mentioned property for inspection purposes. Signature c.. Date /147,a10 Jib- t SCOPE OF WORK LEGEND AND ABBREVIATIONS TABLE OF CONTENTS BUYER ACKNOWLEDGES THAT THE SOLAR PAGE PITCH DESCRIPTION MODULES TO BE INSTALLED PITCH TRUE AZIM MOD COUNT SERVICE ENTRANCE SOLAR MODULES # ON THE ROOF OF THE HOME WILL BE ►MP I RAIL SUBSTANTIALLY IN THE ARRAY 1 21° 180° 6 MAIN PANEL PV-G SITE PLAN LOCATIONS INDICATED BY THE ILLUSTRATION. ARRAY 2 21° 270° 3 SP SUB-PANEL PV-A LAYOUT BUYER(S): STANDOFFS 8 DATE. PLAN 2 ELEVATION A STANDARD ® PV LOAD CENTER FOOTINGS PV-E I ELECTRICAL CHIMNEY ORIENTATION 4 LOT#04 r DEDICATED PV METER PV-E II SIGNAGE C, ATTIC VENT INVERTER(S)WITH • SYSTEM SIZE:2.880 kW INV INTEGRATED DC FLUSH ATTIC VENT • MODULES:(9)LG320NIK-V5 DISCONNECT AND AFCI ) SITE PLAN -SCALE=1/64"-1'-0" ACPVC PIPE VENT (320W AC DISCONNECT(S) METAL PIPE VENT • INVERTER(S):(9)ENPHASE IQ 7+ ,N, O DC DISCONNECT(S) T-VENT • ROOF TYPE:TILE W/COMP CB Q SATELLITE DISH SHINGLE AT ARRAY n COMBINER BOX +� FIRE SETBACKS F BATTERY .t• I HARDSCAPE r :s'aAT r AUTOTRANSFORMER • G ortrM[u I -PL- PROPERTY LINE L 31gI`YUI J j / - BACKED UP LOADS ' _1 INTERIOR EQUIPMENT lu i 31gIn_ / BP PANEL SHOWN AS DASHED 1 a PA( 357.7 AD*337.. 7ffillite'' �� 12Ell SUNSTREET I n,i� ■.��_ SCALE.NTS 8EIGHTY A AMPERE FF- 367.4 1 3 1 4 1 5 16 AC ALTERNATING CURRENT PAD-386. e AFCI ARC FAULT CIRCUIT INTERRUPTER :� 11AZIM AZIMUTHIA 77�� LENNAR.DIVISION ADDRESS COMP COMPOSITION PHONE. DC DIRECT CURRENT FAX (E) EXISTING EXT EXTERIOR CUSTOMER RESIDENCE: PAD.366' - 44 41 FRT FRAMING 2603 DURHAM COURT �#r� INT INTERIOR ARCADIA CA 91007 LBW LOAD BEARING WALL wnwn� MAG MAGNETIC 10 01MSP MAIN SERVICE PANEL TEL MK» Fly �/u (N) NEW i` I NTS NOT TO SCALE PROJECT NUMBER: " •D OC ON CENTER PROJ0109200 JIT9 I p • `-'3 PRE-FAB PRE-FABRICATED - �� DESIGNER.NOE FLORES PSF POUNDS PER SQUARE FOOT 41 40 39 38 37 PH#:303-723-7261 ti �M,�� PV PHOTOVOLTAIC pTL TRANSFORMERLESS III :611 �• TYP TYPICAL DRAFTER'NOE FLORES k111 W VOLTS WATTS t:A 8 9 / /Wrik ,0 ^ i� 12 SHEET COVER SHEET REV NAME DATE COMMENTS I': REV:A 12/4/2019 r F WAIN / i& Mal-A- -EA it R\ A PAGE PV-G SYSTEM LAYOUT-SCALE=3/32"-1'-0" • SYSTEM SIZE:2.880 kW 10_1" • MODULES:(9)LG320NIK-V5 (320W) '% FLASHING INVER • INVERTER(S):(9)ENPHASE IQ 7+ 8'-6" /— 9'-4"- /-8'-6"—)' • ROOF TYPE:TILE W/COMP SHINGLE AT ARRAY (N)ARRAY AR-02 (N)ARRAY AR-01 a (N) FOOT - (N) RAIL a K FIRE SETBACKS e 10'-3 ` a. ,:".: FIRE SETBACKS . . Illi 7 (3'TYP) 0..---000 NO. ` 0000 . 0000 t cl- %0 0000 In SUNSTREET a 1 :"" " d 8EIGHTY 19' 6" 18'-9" T — . FLASHING �_ LENNAR.DIVISION ADDRESS � l PHONE. X v r,.r 0000• soon.— FAX .. • s, OMNI NO ,. • , • ION. IN ON X X 0000 CUSTOMER RESIDENCE: SS :' 'I ', ▪II ONO/ 2603 DURHAM COURT `" ` "" ARCADIA CA 91007 TEL TMKI •• . PROJECT NUMBER " . PROJ0109200 ._ _ ti n - - n a ~ (N) RESIDENCE DESIGNER:NOE FLORES PH#:303-723-7261 (N) PROPERTY LINE DRAFTER:NOE FLORES SHEET SC ) LAYOUT CB REV:A 12/4/2019 -o- L-M J (N) DRIVEWAY PAGE PV-A IOW- 120/240 VAC li SINGLE PHASE SERVICE (` METER# UTILITY O GRID NEW 200 A MAIN BREAKER (N)60A ENPHASE •MAX 13 MICRO-INVERTERS PER BRANCH CIRCUIT AC COMBINER BOX •MULTIPLE BRANCH CIRCUITS IN PARALLEL 20A PV BREAKERS WITH •ENPHASE MULTI-PIN CONNECTORS-1ST AC CONNECTOR AT NEW 10A ENVOY BREAKER EACH BRANCH CIRCUIT IS A SUITABLE DISCONNECTING MEANS. - 200A I •DO NOT DISCONNECT/CONNECT UNDER LOAD ' MAIN (N)LOCKABLE PANEL BLADE TYPE F L�LAD9 - r 3 AC DISCONNECT r 3 2 JUNCTION BOX I iiil -- T_-- _-- -- y xEvm.i I OB EQUIVALENT roiliiiililijiiil ease (1)BRANCH OF G. I m J ® ® V i (9)MICRO-INVERTERS 20A PV ,»0 30A,2P BREAKER AT o 120/240VAC OPPOSITE END OF BUSBAR SYSTEM SIZE OPTION CONDUIT SCHEDULE MODULE POWER SYSTEM SIZE(kW # CONDUCTOR WIRE TYPE TYPE LOCATION TRADE OPTION MODULE QTY. (WATTS DC) DC @STC) 1 1#12 ENPHASE Q CABLE, CU UL3003,DG ARRAY SOLAR 1-66G,FREE AIR CABLE A 9 320 2.88 2 3410,1-#10 EGC CU NM-B(ROMEX) INTERIOR SOLAR 3 3410,1410 EGC CU NM-B(ROMEX) INTERIOR SOLAR CONDUCTOR SIZING CALCULATIONS 1)CONDITION OF USE(COU): (AMPACITY'TEMP.DERATEFILL DERATE)vs.REQ'D( ,) INTERCONNECTION CALCULATIONS 2)TERMINALS(TERM): AMPACITY AT TERMINALS.vs.REQ'D,(IMAX'1.25) KEY SIZE CU/AL INSULATION CALC. AMPACITY W/O TEMP. FILL RESULT REQ'D OCD ITEM UNIT PANEL .- TYPE DEBATES DERATE DERATE (A) (A) USED(A) PANEL MANUFACTURER CUTLER HAMMER U_ , #12 CU THN-2 COU 30 0.76 1.00 22.80 10.98 ... SUNSTREET W TERM 25' 25.00 12.10 20.00 BUS RATING AMPS 200 8EIGHTY 2 #10 CU NM-B COU 40 0.91 1.00 36.40 10.98 MAIN DISCONNECT AMPS 200 TERM 35 35.00 12.00 20.00 3 #10 CU NM-B COU 40' 1.00 1.00 36.00 10.00 ALLOWED PV PER NEC AMPS 40 TERM 35 35.00 12.00 20.00 PV OCPD USED AMPS 20 PENNAR:DIVISION ADDRESS PHONE. FAX MODULE SPECIFICATION AND CALCULATIONS INVERTER SPECIFICATIONS AND CALCULATIONS ITEM NOTE/CALCULATION UNIT DETAIL ITEM NOTE/CALCULATION UNIT DETAIL CUSTOMER RESIDENCE: LOCATION ARCADIA,CA INVERTER MAKE INVERTER SPEC ENPHASE 2603 DURHAM COURT TEMP,AMBIENT HIGHT(Tmax) ASHRAE 2% °C 31 INVERTER MODEL INVERTER SPEC °C IQ7PLUS-72-2-US ARCADIA CA 91007 TEMP.AMBIENT LOW(Troia) ASHRAE EXTREME MIN °C -2 INVERTER MAX POWER(Wac MAX) INVERTER SPEC WATTS(AC) 295 TEMP,MODULE TEST[Rest) MODULE SPEC °C 25 TEL. TMK# TEMP.DELTA LOW(Tdelta) Tn.n-Ttest °C _27 INVERTER INPUT VOLTAGE(Voc MAX) INVERTER SPEC VOLTS(DC) 60 - PROJECT NUMBER: MODULE MANUFACTURER MODULE SPEC LG INVERTER OUTPUT VOLTAGE(Vac NOM) INVERTER SPEC VOLTS(AC) 240 PROJ0109200 MODULE PART NUMBER MODULE SPEC LG320NIK-V5(320W) INVERTER OUTPUT FREQUENCY INVERTER SPEC HERTZ 60 MODULE POWER STC(P) MODULE SPEC WATTS(DC) 320 DESIGNER.NOE FLORES INVERTER OUTPUT CURRENT(lac) INVERTER SPEC AMPS(AC) 1.21 PH#:303-723-7261 MODULE OPERATING VOLTAGE(VMP) MODULE SPEC VOLTS(DC) 33.3 INVERTER PHASE QUANTITY INVERTER SPEC PHASE 1 - MODULE OPEN CIRCUIT VOLTAGE MODULE SPEC VOLTS(DC) 40.8 DRAFTER:NOE FLORES (VOC) COMPLIACE INVERTER SPEC ULI741/IEEE1547 MODULE COEF.VOLT/TEMP(Coal) MODULE SPEC V/C° -0.27 INVERTER GROUNDING INVERTER SPEC ISOLATED 'MODULE MAX VOLTAGE(Vmacmod) (VOC.(TD'COEF)) VOLTS(DC) 48.09 SHEET MODULE OPERATING CURRENT(IMP) MODULE SPEC AMPS(DC) 9.62 INVERTER QTY.MAX PER BRANCH MODULE QTYbc QTY 9 ELECTRICAL MODULE SHORT CIRCUIT CURRENT MODULE SPEC AMPS(DC) 10.19 CIRCUIT _ (ISC) _ BRANCH CIRCUIT OUTPUT(Imaxbc) (IAC-MODULE QTYbc) AMPS(AC) 10.89 REV:A 12/4/2019 MODULE MAXIMUM CURRENT(IMAX) (ISC'1.25) AMPS(DC) 12.74 MINIMUM AMPACITY RED.PER NEX (IMAX'I.25) AMPS(DC) 15 92 INVERTER QTY.TOTAL MODULE QTYI QTY 9 PAGE Q' El SERIES FUSE RATING,MAX MODULE SPEC AMPS(DC) 20 TOTAL SYSTEM OUTPUT(Imaxts) (IAC'MODULE QTYI( AMPS(AC) 10.89 CAUTION • /WARNING Di. WARNING . INVERTER OUTPUT CONNECTION DUAL POWER SUPPLY POWER TO THIS BUILDING IS DO NOT RELOCATE THIS SOURCES: UTILITY GRID ALSO SUPPLIED FROM THE OVERCURRENT DEVICE AND PV SOLAR ELECTRIC FOLLOWING SOURCES WITH LABEL LOCATION SYSTEM ADJACENT \. i DISCONNECTS AS SHOWN APPLCABLEOPVBREAKER(IF ). LABEL LOCATION: PER CODE(S):CEC 2016:705.12(D)(2)(3)(b) UTILITY SERVICE METER AND MAIN I SERVICE PANEL. IN, SOLAR PANELS ON ROOF - - -. PER CODE(S):CEC 2016:705.12(D)(3) AWARNING ELECTRICAL SHOCK HAZARD AWARN I N G DO NOT TOUCH TERMINALS. ELECTRICAL SHOCK HAZARD N TERMINALS ON LINE AND LOAD IF GROUND FAULT IS INDICATED SOLADECK WIRE TRANSITION SIDES MAY BE ENERGIZED IN ALL NORMALLY GROUNDED BOX(UNDER ARRAY) THE OPEN POSITION CONDUCTORS MAY BE LABEL LOCATION: UNGROUNDED AND ENERGIZED PV AC DISCONNECT • INVERTER(S),AC DISCONNECT(S),AC COMBINER PANEL EXTERIOR Pr (IF APPLICABLE). LABEL LOCATION PER CODE(S)CEC 2016.690.17(E) AC COMBINER BOX INVERTER(S),ENPHASE ENVOY ENCLOSURE(IF APPLICABLE). UTILITY METER& PER CODE(S)CEC 2016:690.5(C) MAIN SERVICE PANEL PHOTOVOLTAIC AC DISCONNECT MAXIMUM AC OPERATING CURRENT:10.89 AMPS SERVICE BY QUALIFIED NOMINAL OPERATING AC VOLTAGE: 240 VAC NO PERSONNEL ONLY CONTACT: mSUNSTREET SUNSTREET ENERGY GROUP 1-877-SLR-POWR LABEL LOCATION: 8EIGHTY AC DISCONNECT(S),PHOTOVOLTAIC SYSTEM POINT OF INTERCONNECTION. PER CODE(S):CEC 2016:690.54 PHOTOVOLTAIC SYSTEM LENNAR DIVISION ADDRESS WARNING: PHOTOVOLTAIC FA . EQUIPPED WITH AC DISCONNECT CUSTOMER RESIDENCE. RAPID SHUTDOWN LABEL LOCATION: 2603 DURHAM COURT INTERIOR AND EXTERIOR DC CONDUIT EVERY 10 FT,AT EACH TURN,ABOVE AND ARCADIA CA 91007 BELOW PENETRATIONS,ON EVERY JB/PULL BOX CONTAINING DC CIRCUITS. PER CODE(S).CEC 2016:690.31)G))3),690.31(G)(4) LABEL LOCATION. TEL TMK k UTILITYCO SERVICE ENTRANCE/METER,METER,OR AS REQUIRED BY LOCAL AHJ. WARNING: P H OTOVO LTA I C PER CODE(S):CEC 2016:690.12 PROJECT NUMBER. PROJ0109200 NOTES AND SPECIFICATIONS: DESIGNER:NOE FLORES •SIGNS AND LABELS SHALL MEET THE REQUIREMENTS OF THE CEC 2016 POWERSOURCE PH#:303-723-7261 AND NEC 2014 ARTICLE 110,21(B),UNLESS SPECIFIC INSTRUCTIONS ARE REQUIRED BY SECTION 690,OR IF REQUESTED BY THE LOCAL AHJ. •SIGNS AND LABELS SHALL ADEQUATELY WARN OF HAZARDS USING LABEL LOCATION: DRAFTER:NOE FLORES EFFECTIVE WORDS.COLORS AND SYMBOLS. •LABELS SHALL BE PERMANENTLY AFFIXED TO THE EQUIPMENT OR WIRING INTERIOR AND EXTERIOR DC CONDUIT EVERY 10 FT,AT EACH TURN,ABOVE AND METHOD AND SHALL NOT BE HAND WRITTEN,UNLESS PORTIONS OF BELOW PENETRATIONS,ON EVERY JB/PULL BOX CONTAINING DC CIRCUITS. SHEET LABELS OR MARKINGS ARE VARIABLE,OR THAT COULD BE SUBJECT TO PER CODE(S):CEC 2016.690.31(G)(3),690.31(G)(4) CHANGES.SHALL BE PERMITTED TO BE HAND WRITTEN AND SHALL BE SIGNAGE LEGIBLE. •LABEL SHALL BE OF SUFFICIENT DURABILITY TO WITHSTAND THE ENVIRONMENT INVOLVED. REV:A 12/4/2019 •1 •SIGNS AND LABELS SHALL COMPLY VNTH ANSI Z535.4-2011,PRODUCT SAFETY SIGNS AND LABELS,UNLESS OTHERVNSE SPECIFIED. PAGE E2 Ili* •DO NOT COVER EXISTING MANUFACTURER LABELS.