Loading...
HomeMy WebLinkAboutMNEW-18-1953 City of Arcadia, CA Permit NO. Mnew-18-1953 Development Services Department Permit Type:Multi-Family New 240 West Huntington Drive,Post Office Box 60021 Arcadia,CA 91066-6021 Work Classification:MF/New-Detached Condominium (626)574-5416 Permit Status:Issued ARCADIA Issue Date: 11/26/20191 Expiration: Addr NO. Dir Prefix Street Name Street Suffix Unit City,State,Zip Parcel Number 2610 DURHAM CT ARCADIA, CA 91006 5788020031 Contacts LENNAR HOMES OF CALIFORNIA* Owner LENNAR Applicant 15131 ALTON PKWY 365,Irvine,CA 92618 (949)349-8215 Description:3 BED 2.5 BATH ATTACHED GARAGE PLAN TYPE 1A. Valuation: $ 230,609.26 Tenant PHASE 1 Total Sq Feet: 1,587.00 Plan Check#18-1940 Plan# Fees Amount Payments Amount Paid Building Issuing Fee $47.01 Total Fees $11,304.65 Building Permit Fees $2,127.90 Cash/Receipt#REC-03194-19 $10,123.65 Fire Plan Check $207.48 Cash/Receipt#REC-002760-2018 $1,181.00 Green Building Standard 510.00 Park&Recreation(MFR) $5,919.51 Amount Due: $0.00 Plan Check,Per Hour $973.52 Single Family/Condo/Townhome Impact $1,983.00 Fee Solid Waste Management Fee $6.25colt � � ,Strong Motion Inst.Program Res 529.98 Total: $11,304.65 CALLS FOR INSPECTIONS Request for inspection by telephone at 626-574-5450. Leave a message requesting the address,timeframe and what inspection item is needed. This permit/plan review expires by time limitation and becomes null and void if the work authorized by the permit is not commenced within 180 days from the date of issuance or if the permit is not obtained within 180 days from the date of plan submittal.This permit expires and becomes null and void if any work authorized by this permit is suspended or abandoned for 180 consecutive days or if no progressive work has been verified by a City of Arcadia building inspector for a period of 180 consecutive days. November 26, 2019 Issued By: Date November 26,2019 Page 1 of 1 A. 00,IFOR,vi7♦;• it • PERMIT/PLAN REVIEW APPLICATION 114 lEt11 410 czto• Development Services Department,240 West Huntington Drive,Post Office Box 60021 Arcadia, CA 91066-6021, (626) 574-5416,Fax(626)447-9173 City of Arcadia LICENSED CONTRACTOR'S DECLARATION WORKERS'COMPENSATION DECLARATION VI�i hereby affirm under penalty of perjury that I am licensed under provisions of I hereby affirm under penalty of perjury one of the following: chapter 9(commencing with Section 7000,of Division 3 of the Business and Professions Co e,and my license is in full forcendd effect. ❑ I have and will maintain a certificate of consent to self-insure for workers' License Class___ License No 4# L Exp. Da ' - compensation, as provided for by Section 3700 of the Labor Code, for the — p �, performance of the work for which this permit is issued. Signature of Contractor �I have and will maintain workers'compensation insurance,as required by Section OWNER-BUILDER DECLARATION 3700 of the Labor Code,for the performance of the work for which this permit ❑ I hereby affirm under penalty of perjury that I am exempt from the Contractors is issued.My workers'compensation insurance carrier and policy numbers are: License Law for the following reason(Section 7031.5,Business and Professions Code.Any city or county which requires a permit to construct,alter,improve, Carrier demolish,or repair any structure,prior to its issuance,also required the applicant Policy Number ! //* for such permit to file a signed statement that he or she is licensed pursuant to the provisions of the Contractors License Law(Chapter 9(commencing with Section (This section need not be completed if the permit is for one hundred dollars or less) 7000)of Division 3 of the Business and Professions Code)or that he or she is exempt there from and the basis for the alleged exemption. Any violation of ❑ I certify that in the performance of the work for which this permit is issued,I shall Section 7031.5 by any applicant for a permit subjects the applicant to a civil not employ any person in any manner so as to become subject to the workers' penalty of not more than five hundred dollars($500)): compensation Laws of California,and agree that if I should become subject to the workers'compensation provisions of Section 3700 of the Labor Code,I shall ❑I, as owner of the property, or my employees with wages as their sole forthwith comp with those provisions. , compensation,will do the work,and the structure is not intended or offered for !/ sale(Section 7044,Business and Professions Code:The Contractors License Date 17//5 Signature Law does not apply to an owner of property who builds or improves thereon, or who does such work himself or herself or through his or her own employees,provided that such improvements are not intended or offered for WARNING: Failure to secure Workers'Compensation coverage is unlawful, sale.If,however,the building or improvement is sold within one(1)year of and shall subject an employer to criminal penalties and civil fines up to one completion,the owner-builder will have the burden of proving that he or she hundred thousand dollars($100,000),in addition to the cost of compensation, did not build or improve for the purpose of sale). damages as provided for in Section 3706 of the Labor Code, interest, and attorney's fees. 0 I, as owner of the property, am exclusively contracting with licensed contractors to construct the project(Section 7044,Business and Professions Code:The Contractors License Law does not apply to an owner of property CONSTRUCTION LENDING AGENCY who builds or improves thereon,and who contracts for such projects with a I hereby affirm under penalty of perjury that there is a construction lending agency contractor(s)licensed pursuant to the Contractors License Law). for the performance of the work for which this permit is issued (Section 3097, Civil Code). 0 I am exempt under Section 7044,Business and Professions Code,for this reason: Lender's Name / Date Signature Lender's Address IMPORTANT: APPLICATION IS HEREBY MADE TO THE BUILDING OFFICIAL FOR A PERMIT SUBJECT TO THE CONDITIONS AND RESTRICTIONS SET FORTH ON THIS APPLICATION AND THE FOLLOWING: 1. The City's approved plans and permit inspection card must remain on the job site for use by City inspection personnel. 2. Final inspection of the work authorized by this permit is required.A Certificate of Occupancy must be obtained prior to use and occupancy of new buildings and structures. 3. Per South Coast Air Quality Management District(AQMD)regulations,renovation and remodeling work that results in the removal,stripping,or altering of asbestos containing materials requires an asbestos survey and removal prior to disturbing the asbestos. Please contact AQMD at(909)396-2000 for further information. Name r -)�/%�i�� ,J/�.)1� TitleplAPJOCI—' /7Gjr/- PRINT N I certify that I have read this application and state that the above information is correct and that I am the owner or duly authorized agent of the owner. I agree to comply with all City ordinances and State Laws relating to building construction. I hereby authorize representatives of the City of Arcadia to enter upon the above-mentioned property for inspection purposes. Signature Date hi 7//1' NOTES Building Inspections Date Insp. Plumbing Inspections Date Insp. Z C /0 d`'1ilots- arif 100. Setbacks 210. Under fir./bldg.drain /. ts ' C-Z � 101. Rough grade 211. Copper underslab 102. Figs.&forms 41 � � 212. Rough plumbing /� 103. Pre-slab 213. Rough gas q 1G 104. Floor joists 214. Shower pan 105. Steel 215. Water heater ff-2.c=s-ZOi e 106. Grout lift 216. Roof drains 107. Shear nailing '{-I-2o '217. Building sewer 108. Diaph nailing 218. Water service 109. Roof nailing 3.18. 20219. Final gas 4-1a-2,0110. Framing y-2/-24.,lr ^�220. Fixtures ' . 111. 0cc./Area Sept.Wall 221. Final plumbing 8,-2•2:••24 .ii-//.....c." Sound walls 222. Sewer cap/demo. 113. T-bar'rid 114. Insulation-Flr. Pool Inspections Date Insp. 115. Insulation-Wall , I�?.�+ • 240. Excavation/steel 116. Insulation-Ceil. ,1. Rough plumbing 117. Drywall nailing 5464•?O ,,. 42. Light shell/bonding 118. Interior lath 5 Jet- ' • 243. Underground conduit 119. Exterior lath 57-141-2-40 »7;444. P-trap 120. Finish grade 245. Gas line&test 121. Final building 246. Fence,gates&signs 122. Final demo/lot clear 247. Pool heater 248. Final electric Electrical Inspections Date Insp. 249. Final•lumbin. 150. Power pole 250. Pool cover 151. Sales lot lighting 251. Pool final 152. Under.round conduit 153. Underslab conduit Reroof Inspections Date Insp. 154. UFER ground 270. Pre-reroof insp. 155. Water ground 71• Roof framing 156. Rough electrical 4j-72-26 272. Sheathing nailing 157. Fixtures 273. Final reroof 158. G.F.C.I. 159. E.it.bondin. Sign Inspections Date I Insp. 160. Serviceanel p 6^2Y �p41' :0. Setback/overhang 161. Final electric $-26-20 281. Footing 282. Conduit/wirin. Mechanical Inspections Date Insp. 283. Disconnect 180. Venting/flue 284. Final sign 181. Furnace/A.C. 182. Rouch HVAC -20 u . •I 1 I , D. • I 1 183. Fire dampers 1 290. Fire alarm 184. Furnace compartment 291. Underground supply 185. Combustion air 292. Fire sprinklers 186. Smoke detectors IS 186. +r /6. Monitor system 187. Metal F.P.rough / 294. Hood dry chem. 188. Compressor setback 295. Final 189. Commercial hood 190. Duct shaft Sewers&Offsite Insp. Date I Insp. 191. Final mechanical $-A)-zA 300. Lateral(main to P/L) - 301. Saddle/Y Block Wall Inspections Date Insp. 302. Cess•••Ifilled 200. Footings 303. Sidewalk - 201. Steel/rebar 304. Driveway 202. Grout lift 305. Curb replacement 203. Final wall 306. Trash bin "\' \ ���^� \ ,7 *A \ ,/ rte^2i \•` %/ �^'/`�� r"*� ,! f •^it! \, /. r��?�- �, ;/ r,^ < ,•'-:,,.„). ,::-1',"-i.';;-:';?,,i::,?; �1e�F\\ :.'.4.:',,,,:.,•.,_,.,,._,,,,.:,,,,,,,,,,,,,,,,,,,‘,) 7 I� este Ce'"( rtificate of Occupancy 35:, -- City of Arcadia �= Development Services Department—Building Division • �` f() .-...i'l)).' 1.. .t, '•• ,,-.1 This certificate issued pursuant to the requirements of the y ''''t;-, -''',.."--4 California Building Code certifying that at the time of issuance this structure was in i compliance with the various ordinances of the City regulating building construction or use. %� s ; . '1! Permit No. 18-1953 f ),,, �t Building Address: 2610 DURHAM CT ARCADIA, CA 91007 Y Permit Type: MF NEW Effective CBC: 2016 C.R.C. N ` - `tet Occupancy Code: R 3/U f P Y Zone Code: MU C , a { Final Date: 9-16-2020 Type of Construction: TYPE VB SPRINKLERED '''''>'Lf----:•'..-;" :',1 1 :/d� ...:''...:.:), M+�y Owner: LENNAR HOMES OF CALIFORNIA , ( . _\-.--- - z,.., , ,'-,':::-. , :_,'''..-_'.'-:*,'...,'...':.',: ,..- ',X,:-''. -'.., / < , , +� Kenneth Fields, : ildin: •-ficial ,--:.tH-; 7 � " Post in Conspicuous Place q ,s''' :... _ __ is �i \�- .:k,-,,_ t t )7 -v1 o..r.'„4 �. -i 1� • _ r)i �, _%"o. �,`� .E� �,� -. � � '�`�� �� 'fie �.�/, �`;'�''� ��..� I � :��. _,�\' Ws, i �`a \ `-'� 'I t' �, City of Arcadia, CA Permit No. MEP-19-2563 Development Services Department Permit Type:MEP 240 West Huntington Drive,Post Office Box 60021 Arcadia,CA 91066-6021 Work Classification:MEP Residential (626)574-5416 Permit Status:Issued ARCADIA Issue Date:12/27/20191 Expiration: Addr NO. Dir Prefix Street Name Street Suffix Unit City,State,Zip 2610 DURHAM CT ARCADIA, Contacts LENNAR HOMES OF CALIFORNIA* Owner 15131 ALTON PKWY 365,Irvine,CA 92618 (949)349-8215 1111111111111111111\ APINMIIIIIIIIIIIIIIIIIIIIIIIIIMMINIVIIIIIIIIIIIIIIMIIIIIIIIIIIIIIIIIIIIIIIIIIMEMINIMMi Description:MEP FOR SF NEW. 125 AMP SERVICE.HVAC Valuation: $ 0.00 Tenant SYSTEM PER APPROVED PLANS.HERS REQUIRED FOR FINAL. Total Sq Feet: 0.00 Plan Check# Plan# Fees Amount Payments Amount Paid Bathtubs/or Combo $13.21 Total Fees $795.33 Bidet $26.42 Cash/Receipt#REC-03464-19 $795.33 Clothes Washer $13.21 Compressor 3-5 Ton(3 to 15 hp) $36.35 Amount Due: $0.00 Dishwasher $13.21 Electrical Permit Issuance Fee $47.01 Furnace or Burner<=100,000 BTU $19.86 n ^ Garbage Disposal Fee $13.21 i�.J c O ltp ' D Gas System(Outlets) $62.20 �•J Hood Serviced by Mechanical Exhaust $14.96 Kitchen Sink $13.21 CALLS FOR INSPECTIONS Laundry Trays $13.21 Request for inspection by telephone at 626-574-5450. Leave a message Lavatories $79.26 requesting the address,timeframe and what inspection item is needed. Mechanical Permit Issuance Fee $47.01 Motors,Generators<1 hp $8.07 New Residential Accessory Bldg (sq ft $30.38 This permit/plan review expires by time limitation and becomes null and area) void if the work authorized by the permit is not commenced within 180 days New Residential Elect.(sq ft area) $126.96 from the date of issuance or if the permit is not obtained within 180 days Plumbing Permit Issuance Fee $47.01 from the date of plan submittal.This permit expires and becomes null and Residential Services up to 400 amps $16.48 void if any work authorized by this permit is suspended or abandoned for 180 Sewer Connection on Property $33.01 consecutive days or if no progressive work has been verified by a City of Shower $13.21 Arcadia building inspector for a period of 180 consecutive days. Total: $795.33 December 27, 2019 Issued By: Date December 27,2019 Page 1 of 1 A: r4 1 PERMIT/PLAN REVIEW APPLICATION • c..,..„,_04 lirikil ~ Development Services Department,240 West Huntington Drive,Post Office Box 60021 .ei,,of N Arcadia, CA 91066-6021,(626) 574-5416,Fax(626)447-9173 City of Arcadia LICENSED CONTRACTOR'S DECLARATION WORKERS'COMPENSATION DECLARATION ❑ I hereby affirm under penalty of perjury that I am licensed under provisions of I hereby affirm under penalty of perjury one of the following: Chapter 9(commencing with Section 7000,of Division 3 of the Business and Professions Code,and my license is in full force and effect. ❑ I have and will maintain a certificate of consent to self-insure for workers' License Class License No. E39. Date compensation, as provided for by Section 3700 of the Labor Code, for the Signature of Contractor 40/J , "/ ( performance of the work for which this permit is issued. Dic WNER-BUILDER DECLARATION ❑ I have and will maintain workers'compensation insurance,as required by Section ereby affirm under penalty of perjury that I am exempt from the Contractorscense Law for the following reason(Section 7031.5,Business and Professions 3700 of the Labor Code,for the performance of the work for which this permit is issued.My workers'compensation insurance carrier and policy numbers are: de.Any city or county which requires a permit to construct,alter,improve, Carrier 7;"molish,or repair any structure,prior to its issuance,also required the applicant policy Number //� for such permit to file a signed statement that he or she is licensed pursuant to the provisions of the Contractors License Law(Chapter 9(commencing with Section (This section need not be comp eted if the permit is for one hundred dollars or less) 7000)of Division 3 of the Business and Professions Code)or that he or she is exempt there from and the basis for the alleged exemption. Any violation of ❑ I certify that in the performance of the work for which this permit is issued,I shall Section 7031.5 by any applicant for a permit subjects the applicant to a civil not employ any person in any manner so as to become subject to the workers' penalty of not more than five hundred dollars($500)): compensation Laws of California,and agree that if I should become subject to the workers'compensation provisions of Section 3700 of the Labor Code,I shall 0 I, as owner of the property, or my employees with wages as their sole forthwith corn wits those provisions. compensation,will do the work,and the structure is not intended or offered for Date __7 ' • sale(Section 7044,Business and Professions Code:The Contractors License Signature Law does not apply to an owner of property who builds or improves thereon, or who does such work himself or herself or through his or her own - employees,provided that such improvements are not intended or offered for WARNING: Failure to secure Workers'Compensation coverage is unlawful, sale.If,however,the building or improvement is sold within one(1)year of and shall subject an employer to criminal penalties and civil fines up to one completion,the owner-builder will have the burden of proving that he or she hundred thousand dollars($100,000),in addition to the cost of compensation, did not build or improve for the purpose of sale). damages as provided for in Section 3706 of the Labor Code, interest, and attorney's fees. ❑I, as owner of the property, am exclusively contracting with licensed — contractors to construct the project(Section 7044,Business and Professions Code:The Contractors License Law does not apply to an owner of property CONSTRUCTION LENDING AGENCY who builds or improves thereon,and who contracts for such projects with a I hereby affirm under penalty of perjury that there is a construction lending agency contractor(s)licensed pursuant to the Contractors License Law). for the performance of the work for which this permit is issued (Section 3097, Civil Code). 0 I am exempt under Section 7044,Business and Professions Code,for this reason: Lender's Name Date (d d ISignature — /____A Lender's Address__ IMPORTANT: APPLICATION IS HEREBY MADE TO THE BUILDING OFFICIAL FOR A PERMIT SUBJECT TO THE CONDITIONS AND RESTRICTIONS SET FORTH ON THIS APPLICATION AND THE FOLLOWING: 1. The City's approved plans and permit inspection card must remain on the job site for use by City inspection personnel. 2. Final inspection of the work authorized by this permit is required.A Certificate of Occupancy must be obtained prior to use and occupancy of new buildings and structures. 3. Per South Coast Air Quality Management District(AQMD)regulations,renovation and remodeling work that results in the removal,stripping,or altering of asbestos containing materials requires an asbestos survey and removal prior to disturbing the asbestos.Please contact AQMD at(909)396-2000 for further information. / — Name -----.......)0e.../1 ���... Title f d,-4 ' of--6 i7 PRINT NAME I certify that I have read this application and state that the above information is correct and that I am the owner or duly authorized agent of the owner. I agree to comply with all City ordinances and State Laws relating to building construction. I hereby authorize representatives of the City of Arcadia to enter upon the above-mentioned property for inspection purposes. Signature �� / Date �� 1 •ption Fl One CONSULTING ENGINEERS PAGE 1 OF I STRUCTURAL OBSERVATION REPORT CITY of ARCADIA THIS REPORT INCLUDES ALL CONSTRUCTION WORK THROUGH THE: April 1,2020 PROJECT "Essex"-SFD OPTION ONE J.N. 0918-2286 LOCATION , Arcadia,California BLDG.PERMIT NUMBER Mnew-18-1953 OWNER Lennar Homes LOCATION/DIVISION : Coastal ARCHITECT Angeleno ARCHITECT J.N. 1704 STRUCT.OBS.OF RECORD Ilia Sarad,P.E.,S.E.,S.E.C.B. LIC.OR REGISTRATION No. S-3855 STRUCTURAL OBSERVER Erik Torres,E.I.T. LIC.OR REGISTRATION No. OBSERVED STRUCTURAL ELEMENTS&THEIR CONNECTIONS: LOT(S)&PHASE OBSERVED: Interior and Exterior General Framing;i.e.,roof trusses,roof sheathing, Phase:IB. Tract:77121 shear elements,holdowns,floor sheathing,floor trusses,beams,headers,and HS#7,Plan IA general hardware. 2610 Durham Court Arcadia,California 91007 OBSERVED DEFICIENCIES: (ATTACH ADDITIONAL PAGES IF NECESSARY) Initial/Completion Date The deficiencies noted during the observation visit have been corrected and/or installed by a collaborated effort of the foreman and project superintendent. E.T 04/01/20 Construction Stage: El n HVAC X❑Electrical a Plumbing Double Sided ❑ Plywood CI'g ❑ Deck Option ❑Guard N/A Shear Walls Lid(s) Rails Note:When box is checked,it indicates that construction stage is in progress,and it has not yet been completed at the time of observation was conducted El STRUCTURAL SYSTEM WAS VISUALLY OBSERVED TO BE IN GENERAL CONFORMANCE WITH THE APPROVED PLANS 0 STRUCTURAL DEFICIENCIES ARE OF A MINOR NATURE&MAY BE REVIEWED BY CITY BLDG INSPECTOR FOR COMPLIANCE I DECLARE THAT THE FOLLOWING STATEMENTS ARE TRUE TO THE BEST OF MY KNOWLEDGE AND BELIEF 1. I AM THE REGISTERED ENGINEER WHO HAS RESPONSIBLE CHARGE FOR THE STRUCTURAL OBSERVATION. QROFESS/p � � 2. I,OR ANOTHER QUALIFIED-CHARGE OBSERVER WHO I HAVE DESIGNATED O t ABOVE AND IS UNDER MY RESPONSIBLE CHARGE,HAS PERFORMED THE ~����P 6' Sq p90 4 REQUIRED SITE VISITS AT EACH SIGNIFICANT CONSTRUCTION STAGE TO VERIFY IF THE STRUCTURE IS IN GENERAL CONFORMANCE WITH THE el yr' APPROVED PLANS AND SPECIFICATIONS. o: NO. S 3855 3. ALL DEFICIENCIES,WHICH I DOCUMENTED,HAVE BEEN CORRECTED UNLESS OTHERWISE INDICATED ABOVE. * Exp. 3/31/2022 * 4. ALL OBSERVED DEFICIENCIES SHALL BE CORRECTED AND APPROVED BY THE OBSERVER PRIOR TO FINAL ACCEPTANCE OF THE STRUCTURAL SYSTEMS BY '�qr l RUCT URP � THE BUILDING DEPARTMENT. FoF CALIF 5. THIS REPORT IS PROVIDED TO THE OWNER AS A PART OF THE OWNERS OVERALL CONSTRUCTION QUALITY CONTROL PROGRAM. April 1,2020 6. OPTION ONE HAS PROVIDED STRUCTURAL OBSERVATION IN ACCORDANCE WITH THE SEAOC RECO ENDED GUI D ELINES FOR THE PRACTICE OF STAMP OF ENGINEER-OF-RECORD STRUCTURAL ENGINE ' l• ' C +a( I' IA. SIGNED BY: A 041."-J.i1 April 1,2020 Ilia Sar-.', -.E.,S.E. .E.C..;. STRUCTURAL OBSERVAT ON DOE' NOT WAIVE THE REQUIREMENTS FOR INSPECTIONS BY CITY BUILDING INSPECTORS. ALL WORK MU' COM' Y WITH THE APPROVED PLANS AND APPLICABLE STATE&LOCAL CODES. 226650R_frmg_H57_P1 A Option One Tel 714.556.1916 Consultina Engineers 2755 Bristol Street, Suite 100, Costa Mesa, Ca. 92626 Fax 714.556.1952 rs Option One CONSULTING ENGINEERS PAGE 1 OF 1 STRUCTURAL OBSERVATION REPORT LENNAR HOMES, CA THIS REPORT INCLUDES ALL CONSTRUCTION WORK THROUGH THE: February 13,2020 PROJECT , "Essex"-SFD OPTION ONE J.N. 0918-2286 LOCATION , Arcadia,California BLDG.PERMIT NUMBER Mnew-18-1953 OWNER Lennar Homes LOCATION/DIVISION Coastal ARCHITECT Angeleno ARCHITECT J.N. 1704 STRUCT.OBS.OF RECORD . Ilia Sarad,P.E.,S.E.,S.E.C.B. LIC.OR REGISTRATION No. S-3855 STRUCTURAL OBSERVER Erik Torres LIC.OR REGISTRATION No. OBSERVED STRUCTURAL ELEMENTS&THEIR CONNECTIONS: LOT(S)&PHASE OBSERVED: Conventional Foundation System;i.e.,anchor bolts,holdown bolts&straps, Phase:1B, Tract: 77121 post bases,Strong-WalVHardy Frame anchor bolts,slab size/reinforcement and HS#7,Plan IA footing&pad size/reinforcement(NOTE:monolithic pour system). --2610 Durham Court Arcadia,California 91007 OBSERVED DEFICIENCIES: (ATTACH ADDITIONAL PAGES IF NECESSARY) --___ Initial/Completion Date The deficiencies noted during the observation visit have been corrected and/or installed by a collaborated effort of the foreman and project superintendent. ET. 02/13/20 Construction Stage: Double Sided Plywood CIg Guard u HVAC Electrical Plumbingu Deck Option u N/A Shear Walls Lid(s) Rails Note:When box is checked,it indicates that construction stage is in progress,and it has not yet been completed at the time of observation was conducted ❑X STRUCTURAL SYSTEM WAS VISUALLY OBSERVED TO BE IN GENERAL CONFORMANCE WITH THE APPROVED PLANS STRUCTURAL DEFICIENCIES ARE OF A MINOR NATURE&MAY BE REVIEWED BY CITY BLDG INSPECTOR FOR COMPLIANCE I DECLARE THAT THE FOLLOWING STATEMENTS ARE TRUE TO THE BEST OF MY KNOWLEDGE AND BELIEF 1. I AM THE REGISTERED ENGINEER WHO HAS RESPONSIBLE CHARGE FOR THE STRUCTURAL OBSERVATION. RQF ES$ 2. I,OR ANOTHER QUALIFIED-CHARGE OBSERVER WHO I HAVE DESIGNATED <4.9Q B 044( ABOVE AND IS UNDER MY RESPONSIBLE CHARGE,HAS PERFORMED THE ~43- \P B. .44, e REQUIRED SITE VISITS AT EACH SIGNIFICANT CONSTRUCTION STAGE TO VERIFY IF THE STRUCTURE IS IN GENERAL CONFORMANCE WITH THE APPROVED PLANS AND SPECIFICATIONS. l& NO. S 3855 51 3. ALL DEFICIENCIES,WHICH I DOCUMENTED,HAVE BEEN CORRECTED UNLESS OTHERWISE INDICATED ABOVE. * Exp. 3/31/2020 4. ALL OBSERVED DEFICIENCIES SHALL BE CORRECTED AND APPROVED BY THE S+ �, , OBSERVER PRIOR TO FINAL ACCEPTANCE OF THE STRUCTURAL SYSTEMS BY ,4 R U C T VRP THE BUILDING DEPARTMENT. F OF CAl.\F 5. THIS REPORT IS PROVIDED TO THE OWNER AS A PART OF THE OWNERS OVERALL CONSTRUCTION QUALITY CONTROL PROGRAM. February 13,2020 6. OPTION ONE HAS PROVIDED STRUCTURAL OBSERVATION IN ACCORDANCE WITH THE SEAOC REC• MENDED GUIDELINES FOR THE PRACTICE OF STAMP OF ENGINEER-OF-RECORD STRUCTURAL ENGINE'; I IF RN IA. SIGNED BY: di February 13,2020 Ilia - =el,P.E.,S. .,S. .C.B. STRUCTURAL OBSERV• ION i IES NOT WAIVE THE REQUIREMENTS FOR INSPECTIONS BY CITY BUILDING INSPECTORS. ALL WORK M ST C• PLY WITH THE APPROVED PLANS AND APPLICABLE STATE&LOCAL CODES. 2286508 Foundation HS7 P1A • Option One Tel 714.556.1916 Consultina Enaineers 2755 Bristol Street. Suite 100, Costa Mesa, Ca. 92626 Fax 714.556.1952 City of Arcadia, CA Permit NO.SOLR-20-0453 Development Services Department Permit Type:Solar 240 West Huntington Drive,Post Office Box 60021 Arcadia,CA 91066-6021 Work Classification:Solar-Residential (626)574-5416 Permit Status:Issued ARCADIA Issue Date:04/15/2020 Expiration: 10/12/2020 Addr NO. Dir Prefix Street Name Street Suffix Unit City,State,Zip Parcel Number 2610 DURHAM CT ARCADIA, CA 91006 5788020031 Contacts LENNAR HOMES OF CALIFORNIA* Owner 15131 ALTON PKWY 365,Irvine,CA 92618 (949)349-8215 Description:ROOF MOUNTED SOLAR SYSTEM 8 Valuation: $ 0.00 Tenant MODULES/MICROINVERTERS.SYSTEM SIZE 2.56 KW Total Sq Feet: 0.00 Plan Check#20-453 Plan# Fees Amount Payments Amount Paid Building Plan Check Fee Residential $50.00 Total Fees $308.24 Electrical Permit Issuance Fee $47.01 Cash/Receipt#REC-04265-20 $308.24 Fire Plan Check Fee Residential $50.00 Inverters $77.78 Amount Due: $0.00 Panels $82.45 Solid Waste Management Fee 2 $1.00 Total: $308.24 0 CIO-SID �j/-7Z—Zo esc eri, zGecr se. CALLS FOR INSPECTIONS ' Request for inspection by telephone at 626-574-5450. Leave a message _/2-2-0 �i✓!!G requesting the address,timeframe and what inspection item is needed. This permit/plan review expires by time limitation and becomes null and void if the work authorized by the permit is not commenced within 180 days from the date of issuance or if the permit is not obtained within 180 days from the date of plan submittal.This permit expires and becomes null and void if any work authorized by this permit is suspended or abandoned for 180 consecutive days or if no progressive work has been verified by a City of Arcadia building inspector for a period of 180 consecutive days. April 15, 2020 Issued By: Date April 15,2020 Page 1 of 1 A: • PERMIT/PLAN REVIEW APPLICATION c•_ 141s, * Development Services Department,240 West Huntington Drive,Post Office Box 60021 •t•* Arcadia, CA 91066-6021,(626) 574-5416,Fax (626) 447-9173 City of Arcadia LICENSED CONTRACTOR'S DECLARATION WORKERS'COMPENSATION DECLARATION ❑ I hereby affirm under penalty of perjury that I am licensed under provisions of I hereby affirm under penalty of perjury one of the following: Chapter 9(commencing with Section 7000,of Division 3 of the Business and Professions Code,and my license is in full force and effect. 0 I have and will maintain a certificate of consent to self-insure for workers' License Class License No. Exp. Date compensation, as provided for by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. Signature of Contractor OWNER-BUILDER DECLARATION ❑ I have and will maintain workers'compensation insurance,as required by Section 0 I hereby affirm under penalty of perjury that I am exempt from the Contractors 3700 of the Labor Code,for the performance of the work for which this permit License Law for the following reason(Section 7031.5,Business and Professions is issued.My workers'compensation insurance carrier and policy numbers are: Code.Any city or county which requires a permit to construct,alter,improve, Carrier demolish,or repair any structure,prior to its issuance,also required the applicant for such permit to file a signed statement that he or she is licensed pursuant to the Policy Number provisions of the Contractors License Law(Chapter 9(commencing with Section (This section need not be completed if the permit is for one hundred dollars or less) 7000)of Division 3 of the Business and Professions Code)or that he or she is exempt there from and the basis for the alleged exemption. Any violation of ❑ I certify that in the performance of the work for which this permit is issued,I shall Section 7031.5 by any applicant for a permit subjects the applicant to a civil not employ any person in any manner so as to become subject to the workers' penalty of not more than five hundred dollars($500)): compensation Laws of California,and agree that if I should become subject to the workers'compensation provisions of Section 3700 of the Labor Code,I shall ❑I, as owner of the property, or my employees with wages as their sole forthwith comply with those provisions. compensation,will do the work,and the structure is not intended or offered for sale(Section 7044,Business and Professions Code:The Contractors License Date Signature Law does not apply to an owner of property who builds or improves thereon, or who does such work himself or herself or through his or her own employees,provided that such improvements are not intended or offered for WARNING: Failure to secure Workers'Compensation coverage is unlawful, sale.If,however,the building or improvement is sold within one(1)year of and shall subject an employer to criminal penalties and civil fines up to one completion,the owner-builder will have the burden of proving that he or she hundred thousand dollars($100,000),in addition to the cost of compensation, did not build or improve for the purpose of sale). damages as provided for in Section 3706 of the Labor Code, interest, and attorney's fees. ❑I, as owner of the property, am exclusively contracting with licensed contractors to construct the project(Section 7044,Business and Professions Code:The Contractors License Law does not apply to an owner of property CONSTRUCTION LENDING AGENCY who builds or improves thereon,and who contracts for such projects with a I hereby affirm under penalty of perjury that there is a construction lending agency contractor(s)licensed pursuant to the Contractors License Law). for the performance of the work for which this permit is issued (Section 3097, Civil Code). ❑ I am exempt under Section 7044,Business and Professions Code,for this reason: Lender's Name Date Signature Lender's Address IMPORTANT: APPLICATION IS HEREBY MADE TO THE BUILDING OFFICIAL FOR A PERMIT SUBJECT TO THE CONDITIONS AND RESTRICTIONS SET FORTH ON THIS APPLICATION AND THE FOLLOWING: 1. The City's approved plans and permit inspection card must remain on the job site for use by City inspection personnel. 2. Final inspection of the work authorized by this permit is required.A Certificate of Occupancy must be obtained prior to use and occupancy of new buildings and structures. 3. Per South Coast Air Quality Management District(AQMD)regulations,renovation and remodeling work that results in the removal,stripping,or altering of asbestos containing materials requires an asbestos survey and removal prior to disturbing the asbestos. Please contact AQMD at(909)396-2000 for further information. Name Title PRINT NAME I certify that I have read this application and state that the above information is correct and that I am the owner or duly authorized agent of the owner. I agree to comply with all City ordinances and State Laws relating to building construction. I hereby authorize representatives of the City of Arcadia to enter upon the above-mentioned property for inspection purposes. Signature Date • • PERMIT/PLAN REVIEW APPLICATION • � Development Services Department, 240 West Huntington Drive, Post Office Box 60021 •i Arcadia,CA 91066-6021, (626) 574-5416, Fax (626)447-9173 ONLINE PER^IIT/PLAN RE\'IEWV APPLICATION till Ut L ARCADIA Job Site Address: 2 /40 12Ur'4m, C{ LICENSED CONTRACTOR'S DECLARATION WORKERS'COMPENSATION DECLARATION �I hereby affirm under penalty of perjury that I am licensed under provisions of I hereby affirm under penalty of perjury one of the following: Chapter 9(commencing with Section 7000,of Division 3 of the Business and Professions Code,and my license is in full force and effect. D I have and will maintain a certificate of consent to self-insure for workers' License Class _L[ xp Date compensation, as provided for by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued Signature of Contractor OWNER-BUILDER DECLARATION 1 I have and will maintain workers'compensation insurance,as required by Section 11 I hereby affirm under penalty of perjury that I am exempt from the Contractors 3700 of the Labor Code,for the performance of the work for which this permit License Law for the following reason(Section 7031.3,Business and Professions is bussed My workers'compensation insurance carrier and policy numbers are: Code.Any city or county which requires a permit to construct, alter,improve. Carrier demolish.or repair any structure,prior to its issuance.also required the applicant ) P' 1 ‘ for such permit to file a signed statement that he or she is licensed pursuant to the Policy Number provisions of the Contractors License Law(Chapter 9(commencing with Section (This rection need not be completed if the permit is for one hundred dollars or less) 7000)of Division 3 of the Business and Professions Code)or that he or she is exempt there from and the basis for the alleged exemption. Any violation of ElI certify that in the performance of the work for which this permit is issued 1 shall Section 7031.5 by any applicant for a permit subjects the applicant to a civil not employ any person in any manner so as to become subject to the workers' penalty of not more than five hundred dollars($500)): compensation Laws of California.and agree that if I should become subject to the workers'compensation provisions of Section 3700 of the Labor Code.I shall I. as owner of the property, or my employees with wages as their sole forthwith comply with those provisions compensation,will do the work,and the structure is not intended or offered for License ��/J, sale(Section 7044, Business and Professions Code:The Contractors Date Signature !I Law does not apply to an owner of property who builds or improves thereon. or who does such work himself or herself or through his or her own employees, provided that such improvements are not intended or offered for WARNING: Failure to secure Workers'Compensation coverage is unlawful. sale. If,however.the building or improvement is sold within one(I)year of and shall subject an employer to criminal penalties and civil fines W to one completion,the owner-builder will have the burden of proving that he or she hundred thousand dollars($100,000),in addition to the cost of compensation. did not build or improve for the purpose of sale). damages as provided for n Section 3706 of the labor Code. interest. and attorney's fees I. as owner of the property, am exclusively contracting with licensed contractors to construct the project (Section 7044,Business and Professions Code:The Contractors License Law does not apply to an owner of property CONSTRUCTION LENDING AGENCY who builds or improves thereon.and who contracts for such projects with a I hereby affirm under penalty of perjury that there is a construction lending agency contractor(s)licensed pursuant to the Contractors License Law). for the performance of the work for which this permit is issued (Section 3097. Civil Code). ❑ I am exempt under Section 7044.Business and Professions Code,for this reason. Lender's Name Date Signature Lender's Address IMPORTANT: ANTIC\TI(►N IS HLKUIBY MADE 11) MIL Ill 11.D1\G 0141('1:11 10K 1 PLK\ttI St I1,11-.('I 1(i 1111- U0\1111 IONS 1\li KESTKl(1IONS SF:I Fl►KI t)N THIS,1I'1'I.I(':\I ION AND'f11F:l 01.1.1)111\1,: I. The City's approved plans and permit inspection card must remain on the job site for use by City inspection personnel 2. Final inspection of the work authorized by this permit is required A Certificate of Occupancy must be obtained prior to use and occupancy of new buildings and structures 3 Per South Coast Air Quality Management Distract(AQMD)regulations,renovation and remodeling work that results in the removal,stripping,or altenng of asbestos containing materials requires an asbestos survey and removal prior to disturbing the asbestos. Please contact AQMD at(909)396-2000 for further information. Name Title PRINT NAME I certify that I have read this application and state that the above Information is correct and that I am the owner or duly authorized agent of the owner. I agree to comply with all City ordinances and State Laws relating to building construction. I hereby authorize representatives of the City of Arcadia to enter upon the above-mentioned property for inspection purposes. 4141;o Signature Date e SCOPE OF WORK LEGEND AND ABBREVIATIONS TABLE OF CONTENTS BUYER ACKNOWLEDGES THAT THE SOLAR ► SOLAR MODULES PAGE# DESCRIPTION MODULES TO BE INSTALLED PITCH TRUE AZIM MOD COUNT ® SERVICE ENTRANCE ON THE ROOF OF THE HOME WILL BE A rr RAIL SUBSTANTIALLY IN THE ARRAY 1 21° 180° 8 MP MAIN PANEL 1 PV-G SITE PLAN LOCATIONS INDICATED BY THE ILLUSTRATION. SP SUB-PANEL PV-A LAYOUT BUYER: STANDOFFS& PLAN 1 ELEVATION A LC PV LOAD CENTER FOOTINGS PV-E I ELECTRICAL DATE: CHIMNEY ORIENTATION 2 LOT#07 m, DEDICATED PV METER PV-E II SIGNAGE ATTIC VENT INVERTER(S)WITH • SYSTEM SIZE:2.560 kW INV INTEGRATED DCFLUSH ATTIC VENT • MODULES:(8)LG320NIK-V5 DISCONNECT AND AFCI O PVC PIPE VENT SITE PLAN-SCALE= 1/64"-1'-0" O AC DISCONNECT(S) ® (320W) METAL PIPE VENT • INVERTER(S):(8)ENPHASE /\ DC DC DISCONNECT(S) Ig T-VENT IQ 7+ 1N/ I= • ROOF TYPE:TILE W/COMP CB CP SATELLITE DISH SHINGLE AT ARRAY 1-1 COMBINER BOX +� FIRE SETBACKS F BATTERY 'w[7 imp/ � HARDSCAPE ownEu11:1-: G AT AUTOTRANSFORMER L �7g_, —PL— PROPERTY LINE - fU I rs� `- - - BP PANELD UP LOADS IL--3 SHOWN AS DASHED ` NT ..... _ >`< %� „. . `'� �*+m . 1 SUNSTREET Xti �' " SCALE-NTS BEIGHTY � A AMPERE —/ 13 14 15 16 AC ALTERNATING CURRENT �, e J AFCI ARC FAULT CIRCUIT INTERRUPTER : — J �/ D AZIM AZIMUTH f D a LENNAR.DIVISION ADDRESS COMPCOMPOSITION PHONE DCCCURRENT CURRRB ENT FAX (E) EXISTING EXT EXTERIOR CUSTOMER RESIDENCE: \ t \114-4 \LLeT FRM FRAMING itiINT INTERIOR 2610 DURHAM COURT Olenitll . �/ LBW LOAD BEARING WALL ARCADIA,CA 91007 %3 .4MAG MAGNETIC J "11-W iii MSP MAIN SERVICE PANEL TEL TMK# S� 335.5I (N) NEW NTS NOT TO SCALE PROJECT NUMBER: / r \ I .3 ON CENTER PROJ0109200 — v V PRE-FAB PRE-FABRICATED DESIGNER:NOE FLORES — 41 40 39 38 37 PSF POUNDS PER SQUARE FOOT DPHE#:303-723-7261 PV PHOTOVOLTAIC TL TRANSFORMERLESS DRAFTER:NOEFLORES I I i / • II ��,• T PTYPICALV OTS r5° LJ W WATTS SHEET B + { / i io iss�� 12\ COVER SHEET REV NAME DATE COMMENTS �?�! REV:A 3/31/2020 • \ 61t11%.- MIMI °'6 AfIl rri` IF- ! fl 4k�- A PAGE PV-G �I ,qy SYSTEM LAYOUT-SCALE=3/32"-1'-0" • SYSTEM SIZE:2.560 kW • MODULES:(8)LG320NIK-V5 (N) RAIL (320W) �= • INVERTER(S):(8)ENPHASE 3' 5•-5" /—2'-10" IQ 7+ (N) FOOT • ROOF TYPE:TILE W/COMP R R R R R SHINGLE AT ARRAY d p k FIRE SETBACKS 00.0 "`"" 0001 (18"TYP) " Offigig J FIRE SETBACKS ::: . O "Of` WOX ` (3'TYP) ::: . - • •• [ I r -j- - 4'TYP iiii d .. .. 27' 7., • 26' 10" -0s SO XO r FLASHING • .•" •• •• � — — SUNSTREET O 000 00 00 0000 •0`•0` � .L..__. .$ - "▪"" "` "' 8EIGHTY [ i• :, LENNAR:DIVISION ADDRESS PHONE 9 • • FAX ✓ r 4'-r CUSTOMER RESIDENCE 1 "" """' 2610 DURHAM COURT ARCADIA,CA 91007 TEL TMK. d r - a a PROJECT NUMBER PROJECT N 0 DESIGNER NOE FLORES PH#:303-723-7261 O AC 91=1- .�-. DRAFTER:NOE FLORES (N)ARRAY AR-01- (N) PROPERTY LINE el(N) DRIVEWAY SHEET LAYOUT (N) RESIDENCE REV:A 3/31/2020 4 PAGE PV-A r g 120/240 VAC SINGLE PHASE SERVICE OSI METER# UTILITY M GRID MAIN (N)60A ENPHASE Ill NEW 200 A BREAKER AC COMBER BOX 20A PV BREAKER WITH •ENP?SE MULTI-IN MICRO-INVERTERS ONNECTORS-1 SUITS IN TLAC CONNECTOR AT I NEW 10A ENVOY BREAKER EACH BRANCH CIRCUIT ISA SUITABLE DISCONNECTING MEANS. I 200AMAIN •DO NOT DISCONNECT/CONNECT UNDER LOAD MAIN (N)LOCKABLE PANEL BLADE TYPE FACILITY /-3 AC DISCONNECT 3 2 JUNCTION Box - LOADSre. , ' 4 OR EQUIVALENT IMINIESMINI1 -1■ -1 -.__ _ -L.r._�-.4 I (1)BRANCH OF „■■ ± (8)MICRO-INVERTERS -T_ l I-m1- I 1. j 20A PV "+4 30A,2P ..... BREAKER AT 120240VAC OPPOSITE END OF BUSBAR SYSTEM SIZE OPTION CONDUIT SCHEDULE MODULE POWER SYSTEM SIZE(kW # CONDUCTOR WIRE TYPE TYPE LOCATION TRADE OPTION MODULE QTY_ (WATTS DC) DC @STC) 1 1#12 ENPHASE O CABLE, CU UL3003,DG ARRAY SOLAR 146G,FREE AIR CABLE A 8 320 2.56 2 3410,1410 EGC CU NM-B(ROMEX) INTERIOR SOLAR 3 3410,1-#10 EGC CU NM-B(ROMEX) INTERIOR SOLAR CONDUCTOR SIZING CALCULATIONS 1)CONDITION OF USE(COU): (AMPACITY'TEMP.DERATE'FILL DERATE)vs.RED'D(4,„x) INTERCONNECTION CALCULATIONS 2)TERMINALS(TERM): AMPACITY AT TERMINALS.vs.REO'D,(IMAX•1.25) ITEM UNIT PANEL KEY SIZE CU/AL INSULATION CALC. AMPACITY W/O TEMP. FILL RESULT REQ'D OCD TYPE DEBATES DERATE DERATE (A) (A) USED(A) PANEL MANUFACTURER CUTLER HAMMER = SUNSTREET 1 #12 CU THWN-2 COU 30 0.76 1.00 22.80 9.68 TERM 25 25.00 12.10 20.00 BUS RATING AMPS 200 8EIGHTY 2 #10 CU NM-B COU 40 0.91 1.00 36.40 9.68 MAIN DISCONNECT AMPS 200 TERM 35 35.00 12.00 20.00 3 #10 CU NM-B COU 40 1.00 1.00 36.00 10.00 ALLOWED PV PER NEC AMPS 40 TERM 35 35.00 12.00 20.00 PV OCPD USED AMPS 20 LENNAR.DIVISION ADDRESS PHONE FAX MODULE SPECIFICATION AND CALCULATIONS INVERTER SPECIFICATIONS AND CALCULATIONS ITEM NOTE/CALCULATION UNIT DETAIL ITEM NOTE/CALCULATION UNIT DETAIL CUSTOMER RESIDENCE- LOCATION ARCADIA,CA INVERTER MAKE INVERTER SPEC ENPHASE 2610 DURHAM COURT TEMP,AMBIENT HIGHT(Truax) ASHRAE 2% °C 31INVERTER MODEL INVERTER SPEC °C IQ7PLUS-72-2-US ARCADIA,CA 91007 TEMP.AMBIENT LOW(Tmn) ASHRAE EXTREME MIN °C -2 INVERTER MAX POWER(Wac MAX) INVERTER SPEC WATTS(AC) 295 TEMP,MODULE TEST(Ttest) MODULE SPEC °C 25 TEL. TMK a TEMP.DELTA LOW(TdeBa) Tmn-Ttast °C _27 INVERTER INPUT VOLTAGE(Voc MAX) INVERTER SPEC VOLTS(DC) 60 PROJECT NUMBER. MODULE MANUFACTURER MODULE SPEC LG INVERTER OUTPUT VOLTAGE(Vac NOM) INVERTER SPEC VOLTS(AC) 240 PROJ0109200 MODULE PART NUMBER MODULE SPEC LG320N1K-V5(320W) INVERTER OUTPUT FREQUENCY INVERTER SPEC HERTZ 60 MODULE POWER STC(P) MODULE SPEC WATTS(DC) 320DESIGNER:NOE FLORES INVERTER OUTPUT CURRENT(lac) INVERTER SPEC AMPS(AC) 1.21 PH#:303-723-7261 MODULE OPERATING VOLTAGE(VMP) MODULE SPEC VOLTS(DC) 33.3 INVERTER PHASE QUANTITY INVERTER SPEC PHASE 1 MODULE OPEN CIRCUIT VOLTAGE MODULE SPEC VOLTS(DC) 40.8 DRAFTER:NOE FLORES (VOC) COMPLIACE INVERTER SPEC UU741/IEEE1547 MODULE COEF.VOLT/TEMP(Coe) MODULE SPEC V/C° -0.27 INVERTER GROUNDING INVERTER SPEC ISOLATED MODULE MAX VOLTAGE(Vmacmod) (VOC*(TD'COEF)) VOLTS(DC) 4809 SHEET MODULE OPERATING CURRENT(IMP) MODULE SPEC AMPS(DC) 9-62 INVERTER QTY.MAX PER BRANCH MODULE QTYbc QTY 8 ELECTRICAL MODULE SHORT CIRCUIT CURRENT MODULE SPEC AMPS(DC) 10.19 CIRCUIT - (ISC) BRANCH CIRCUIT OUTPUT(Imaxbc) (IAC'MODULE QTYbc) AMPS(AC) 969 REV:A 3/31/2020 MODULE MAXIMUM CURRENT(IMAX) (ISC'1.25) AMPS(DC) 12.74 INVERTER QTY.TOTAL MODULE QTYt QTY 9 PAGE MINIMUM AMPACITY REQ'D.PER NEX (IMAX'1.25) AMPS(DC) 15.92 E-1 SERIES FUSE RATING,MAX MODULE SPEC AMPS(DC) 20 TOTAL SYSTEM OUTPUT(Irrlaxis) (IAC'MODULE QTYt) AMPS(AC) 968 CAUTION • /WARNING / WARNING INVERTER OUTPUT CONNECTION DUAL POWER SUPPLY POWER TO THIS BUILDING IS DO NOT RELOCATE THIS I SOURCES: UTILITY GRID ALSO SUPPLIED FROM THE OVERCURRENT DEVICE AND PV SOLAR ELECTRIC FOLLOWING SOURCES WITH LABEL LOCATION: SYSTEM ADJACENT TO PV BREAKER(IF LABEL LOCATION: DISCONNECTS AS SHOWN APPLICABLE). UTILITY SERVICE METER AND MAIN PER CODE(S):CEC 2016:705.12(D)(2)(3)(b) SERVICE PANEL. SOLADECK WIRE TRANSITION PER CODE(S):CEC 2016:705.12(D)(3) 1k r BOX(UNDER ARRAY) AWARNING SOLAR PANELS ON ROOF -pi AWARNING ELECTRICAL SHOCK HAZARD _ .441 DO NOT TOUCH TERMINALS. ELECTRICAL SHOCK HAZARD TERMINALS ON LINE AND LOAD IF GROUND FAULT IS INDICATED SIDES MAY BE ENERGIZED IN ALL NORMALLY GROUNDED f%r�a'f i PV AC DISCONNECT THE OPEN POSITION CONDUCTORS MAY BE // l EXTERIOR LABEL BEELLO AT ION DISCONNECT(S).AC COMBINER PANEL UNGROUNDED AND ENERGIZED (IF APPLIC AC COMBINER BOX PERCODE(SS))C)EC 2016:690.17(E) LABEL LOCATION INVERTER(S),ENPHASE ENVOY ENCLOSURE(IF UTILITY METER &MAIN APPLICABLE) PER CODE(5).CEC 2016:690.5(C) SERVICE PANEL PHOTOVOLTAIC AC DISCONNECT SERVICE BY QUALIFIED MAXIMUM AC OPERATING CURRENT: 9.69 AMPS SM PERSONNEL ONLY CONTACT: NOMINAL OPERATING AC VOLTAGE: 240 VAC sn SUNSTREET SUNSTREET ENERGY GROUP _ _ 1-877-SLR-POWR LABEL LOCATION: 8EIGHTY AC DISCONNECT(S),PHOTOVOLTAIC SYSTEM POINT OF INTERCONNECTION. PHOTOVOLTAIC SYSTEM PER CODE(S):CEC 2016:690.54 LENNAR.DIVISION ADDRESS WARNING: PHOTOVOLTAIC PHONE EQUIPPED WITH AC DISCONNECT CUSTOMER RESIDENCE. RAPID SHUTDOWN ABEL LOCATION 2610 DURHAM COURT INTERIOR AND EXTERIOR DC CONDUIT EVERY 10 FT.AT EACH TURN,ABOVE AND ARCADIA,CA 91007 BELOW PENETRATIONS,ON EVERY JB/PULL BOX CONTAINING DC CIRCUITS. LABEL LOCATION. PER CODE(S) CEC 2016:690.31(G)(3).690.31(G((4) UTILITY SERVICE ENTRANCE/METER,OR AS REQUIRED BY LOCAL AHJ. TEL. TMK x PER CODE(S).•CEC 2016 690.12 / PROJECT NUMBER. PROJ0109200 NOTES AND SPECIFICATIONS: WARNING: PHOTOVOLTAIC]•SIGNS AND LABELS SHALL MEET THE REQUIREMENTS OF THE CEC 2016 DESIGNER:NOE FLORES AND NEC BY E ARTICLE 110.2103),.UNLESS SPECIFICED INSTRUCTIONS ARE POWERSOURCE REQUIRED BY SECTION 690,OR IF REQUESTED BY THE LOCAL AHJ. PH#:303-723-7261 •SIGNS AND LABELS SHALL ADEQUATELY WARN OF HAZARDS USING EFFECTIVE WORDS,COLORS AND SYMBOLS. ' DRAFTER:NOE FLORES •LABELS SHALL BE PERMANENTLY AFFIXED TO THE EQUIPMENT OR WIRING METHOD AND SHALL NOT BE HAND WRITTEN,UNLESS PORTIONS OF LABEL LOCATION. LABELS OR MARKINGS ARE VARIABLE,OR THAT COULD BE SUBJECT TO INTERIOR AND EXTERIOR DC CONDUIT EVERY 10 FT,AT EACH TURN,ABOVE AND CHANGES,SHALL BE PERMITTED TO BE HAND WRITTEN AND SHALL BE BELOW PENETRATIONS,ON EVERY JB/PULL BOX CONTAINING DC CIRCUITS. SHEET LEGIBLE. PER CODE(S):CEC 2016:690.31(G)(3).690.31(G)(4) SIGNAGE •LABEL SHALL BE OF SUFFICIENT DURABILITY TO WITHSTAND THE ENVIRONMENT INVOLVED. •SIGNS AND LABELS SHALL COMPLY WITH ANSI Z535.4-2011,PRODUCT REV:A 3/31/2020 i SAFETY SIGNS AND LABELS.UNLESS OTHERWISE SPECIFIED. •DO NOT COVER EXISTING MANUFACTURER LABELS. PAGE E-2 Y�