HomeMy WebLinkAboutMNEW-18-1960 •
City of Arcadia, CA Permit NO. Mnew-18-1960
Development Services Department Permit Type:Multi-Family New
240 West Huntington Drive,Post Office Box 60021
Arcadia,CA 91066-6021 Work Classification:MF/New- Detached Condominium
(626)574-5416 Permit Status: Issued
AR+CADIA. Issue Date: 11/26/2019 Expiration:
•
Addr NO. Dir Prefix Street Name Street Suffix Unit City,State,Zip Parcel Number
2614 DURHAM CT ARCADIA,CA 91006 5788020031
Contacts
LENNAR HOMES OF CALIFORNIA* Owner LENNAR Applicant
15131 ALTON PKWY 365,Irvine,CA 92618
(949)349-8215
Description:3 BED,3.5 BATH WITH ATTACHED GARAGE PLAN Valuation: $ 313,646.49 Tenant
2A. PHASE 1
Total Sq Feet: 2.186.00 Plan Check#18-1948 Plan#
Fees Amount Payments Amount Paid
Building Issuing Fee $47.01 Total Fees $14,443.26
Building Permit Fees $2,700.60 Cash/Receipt#REC-002767-2018 $1,498.84
Fire Plan Check $263.31 Cash/Receipt#REC-03195-19 $12,944.42
Green Building Standard $13.00
Park&Recreation(MFR) $8,153.78 Amount Due: $0.00
Plan Check,Per Hour $1,235.53
Single Family/Condo/Townhome Impact $1,983.00 q
Fee '3/t� /--443---Z-6Solid Waste Management Fee $6.25
Strong Motion Inst.Program Res $40.78
Total: $14,443.26 CALLS FOR INSPECTIONS
Request for inspection by telephone at 626-574-5450. Leave a message
requesting the address,timeframe and what inspection item is needed.
CICairn]
This permit/plan review expires by time limitation and becomes null and
J void if the work authorized by the permit is not commenced within 180 days
from the date of issuance or if the permit is not obtained within 180 days
from the date of plan submittal.This permit expires and becomes null and
void if any work authorized by this permit is suspended or abandoned for 180
consecutive days or if no progressive work has been verified by a City of
Arcadia building inspector for a period of 180 consecutive days.
November 26, 2019
Issued By: Date
November 26,2019 Page 1 of 1
%FA•
4h PERMIT/PLAN REVIEW APPLICATION •
4lam*' Development Services Department,240 West Huntington Drive,Post Office Box 60021
mvw„'a*" Arcadia, CA 91066-6021, (626) 574-5416,Fax (626)447-9173
City of
Arcadia
LICENSED CONTRACTOR'S DECLARATION WORKERS'COMPENSATION DECLARATION
QI hereby affirm under penalty of perjury that I am licensed under provisions of I hereby affirm under penalty of perjury one of the following:
Chapter 9(commencing with Section 7000,of Division 3 of the Business and
Professions C and my license is in full force and effect. 0 I have and will maintain a certificate of consent to self-insure for workers'
License Class License No. Ex . Date compensation, as provided for by Section 3700 of the Labor Code, for the
� performance of the work for which this permit is issued.
Signature of Contractor
OWNER-BUILDER CLARATION .frilk have and will maintain workers'compensation insurance,as required by Section
❑ I hereby affirm under penalty of perjury that I am exempt from the Contractors 700 of the Labor Code,for the performance of the work for which this permit
License Law for the following reason(Section 7031.5,Business and Professions is issued.My workers'compensation insurance carrier and policy numbers are:
Code.Any city or county which requires a permit to construct,alter,improve, Carrier O J
demolish,or repair any structure,prior to its issuance,also required the applicant
for such permit to file a signed statement that he or she is licensed pursuant to the Policy Number
provisions of the Contractors License Law(Chapter 9(commencing with Section (This section need not be completed if e permit is for one hundred dollars or less)
7000)of Division 3 of the Business and Professions Code)or that he or she is
exempt there from and the basis for the alleged exemption. Any violation of 0 I certify that in the performance of the work for which this permit is issued,I shall
Section 7031.5 by any applicant for a permit subjects the applicant to a civil not employ any person in any manner so as to become subject to the workers'
penalty of not more than five hundred dollars($500)): compensation Laws of California,and agree that if I should become subject to the
workers'compensation provisions of Section 3700 of the Labor Code,I shall
I, as owner of the property, or my employees with wages as their sole forthwith comply wi those provisions.
compensation,will do the work,and the structure is not intended or offered for �A
sale(Section 7044 Business and Professions Code:The Contractors License Date / rf ' Signature / 7
Law does not apply to an owner of property who builds or improves thereon,
or who does such work himself or herself or through his or her own
employees,provided that such improvements are not intended or offered for WARNING: Failure to secure Workers'Compensation coverage is unlawful,
sale.If,however,the building or improvement is sold within one(1)year of and shall subject an employer to criminal penalties and civil fines up to one
completion,the owner-builder will have the burden of proving that he or she hundred thousand dollars($100,000),in addition to the cost of compensation,
did not build or improve for the purpose of sale). damages as provided for in Section 3706 of the Labor Code, interest, and
attorney's fees.
❑I, as owner of the property, am exclusively contracting with licensed
contractors to construct the project(Section 7044,Business and Professions
Code:The Contractors License Law does not apply to an owner of property CONSTRUCTION LENDING AGENCY
who builds or improves thereon, and who contracts for such projects with a I hereby affirm under penalty of perjury that there is a construction lending agency
contractor(s)licensed pursuant to the Contractors License Law). for the performance of the work for which this permit is issued (Section 3097,
Civil Code).
❑ I am exempt under Section 7044,Business and Professions Code,for this reason:
Lender's Name �r
Date Signature Lender's Address
IMPORTANT: APPLICATION IS HEREBY MADE TO THE BUILDING OFFICIAL FOR A PERMIT SUBJECT TO THE CONDITIONS AND
RESTRICTIONS SET FORTH ON THIS APPLICATION AND THE FOLLOWING:
1. The City's approved plans and permit inspection card must remain on the job site for use by City inspection personnel.
2. Final inspection of the work authorized by this permit is required.A Certificate of Occupancy must be obtained prior to use and occupancy of new buildings
and structures.
3. Per South Coast Air Quality Management District(AQMD)regulations,renovation and remodeling work that results in the removal,stripping,or altering
of asbestos containing materials requires an asbestos survey and removal prior to disturbing the asbestos.Please contact AQMD at(909)396-2000 for
further information.
Name Title
PRINT NAME
I certify that I have read this application and state that the above information is correct and that I am the owner or duly authorized agent of the owner.
I agree to comply with all City ordinances and State Laws relating to building construction. I hereby authorize representatives of the City of
Arcadia to enter upon the above-mentioned property for inspection purposes.
SignatureDate
/1/1 7/5
•
• NOTES
Building Inspections Date Insp. Plumbing Inspections I Date Insp. (pl trLIIM
100. Setbacks 210. Under fir/bldg.drain -,1
101. Rough grade ��211. Copper underslab
S�
102. Fi.s.&forms -- /t�o� 212. Rou•h.lumbin.
103. Pre-slab 213. Rough gas °QIN
104. Floor joists 214. Shower pan
105. Steel 215. Water heater
106. Grout lift 216. Roof drains
107. Shear nailing 41`/-Lo 217. Building sewer
108. Diaph nailing C`3-ZA 218. Water service
109. Roof nailing 3-?3,2o 219. Final gas ‘--/o Za
110. Framing Y Zi-z4, 220. Fixtures
111. Occ./Area Sept.Wall 221. Final plumbing =- -�
112. Sound walls 222. Sewer cap/demo.
113. T-bar.rid
114. Insulation-Flr. -11.1. Pool Inspections Date I Insp.
115. Insulation-Wall 4e24240. Excavation/steel
116. Insulation-Ceil. 41. Rough plumbing
117. Drywall nailing -/`1-20 i 242. Light shell/bonding
g 2
118. Interior lath i/ 0 / 243. Underground conduit
119. Exterior lath - -6eZb 244. P-trap
120. Finish grade 45. Gas line&test
121. Final building 7-‘13-2/..)•, 246. Fence,gates&signs
122. Final demo/lot clear 247. Pool heater
248. Final electric
Electrical Inspections Date Insp. 249. Final.lumbin.
150. Power pole 250. Pool cover
151. Sales lot lighting 251. Pool final
152. Under.round conduit
153. Underslab conduit - Reroof Inspections I Date I Insp.
154. UFER ground 270. Pre-reroof insp.
155. Water ground 71. Roof framing
156. Rough electrical -ZO 272. Sheathing nailing
157. Fixtures 273. Final reroof
158. G.F.C.I.
159. E..t.bondin. -NNE Sign Inspections I Date I Insp.
160. Service panel b Z`L 80. Setback/overhang
161. Final electric Zb 281. Footing
282. Conduit/wirin.
Mechanical Inspections Date Insp. 283. Disconnect --
180. Venting/flue -�284. Final sign --
181. Furnace/A.C.
182. Rouch HVAC Ip "• • •I I Date Insp.
183. Fire dampers 290. Fire alarm
184. Furnace compartment 291. Underground supply
185. Combustion air 292. Fire sprinklers
186. Smoke detectors $-Z(-Z-o - 293. Monitor system
187. Metal F.P.rough 294. Hood dry chem.
188. Compressor setback 295. Final
189. Commercial hood
190. Duct shaft MPBM Sewers&Offsite Insp. Date I Insp.
Mira
191. Final mechanical 300. Lateral(main to P/L)
301. Saddle/Y
Block Wall Inspections Date Insp. 302. Cess.•.l filled
200. Footings 303. Sidewalk
201. Steel/rebar 304. Driveway
202. Grout lift 305. Curb replacement
203. Final wall 306. Trash bin
-------„,„"...„-----______-_,„,,,,..-- --_-___----. -- ,,,,,,..---7 \
,,
, 2,-..-----,:---7-------,-,..\ ;,,...„----\ 1-------- A X,-,--------\--7-------. i(,:----- \ / ------,,,•\ it'v----- \ / -------„),," ,-.(---- \ / ------,,,,,/..„„------ ,, / ------,,,t\_/..\,.----- \, i --„,:7,,,,_,,,,, „,
22
C', `-�" 7;:r_. : ._ a ). �; ,,i; - k -.. - `i' -t - - _ (�l \,moi --- '�' `',n
1112 ..
, i
01 IF,Eim ?le
-- i 1
Certificate of Occupancy „ '),-,-:
,11'1 1:.'1:1'''''':.l 'g)"%fr"'-.-_ .- ---::., ,-.„
,, City of Arcadia
Development Services Department—Building Division �-
This certificate issued pursuant to the requirements of the 7,:i
, ';:,,,,T.k‘';'1'-‘3:-.,,,,.,
I :
x a : California Building Code certifying that at the time of issuance this structure was in .
►� compliance with the various ordinances of the Cityregulating buildingconstruction or use. J� =F
> p g g .
�, ova
` Permit No. 18-1960
,:_1,-'„f,/_ -,C
• �' \ Building Address: 2614 DURHAM CT ARCADIA, CA 91007
Permit Type: MF NEW Effective CBC: 2016 C.R.C. if ,,,,,,
i- . 1
1 Occupancy Code: R-3/U Zone Code: MU
( 77
1 ,
Final Date: 9-16-2020 Type of Construction: TYPE VB SPRINKLERED
711
.
Owner: LENNAR HOMES OF CALIFORNIA =, m
7 ,..„ , *
(/ ���3.., Vii;..
1 C�
r
Kenneth Fie s uildi'g• icial
Post in Conspicuous Place
City of Arcadia, CA Permit NO. MEP-19-2569
Development Services Department Permit Type:MEP
240 West Huntington Drive,Post Office Box 60021 Work Classification:MEP-Residential
Arcadia,CA 91066-6021
(626)574-5416 Permit Status:Issued
ARCADIA Issue Date:12/27/2019 f Expiration:
Addr NO. Dir Prefix Street Name Street Suffix Unit City,State,Zip
2614 DURHAM CT ARCADIA,
Contacts
•
•
LENNAR HOMES OF CALIFORNIA* Owner
15131 ALTON PKWY 365, Irvine,CA 92618
(949)349-8215
Description:FOR SF NEW. 125 AMP SERVICE.HVAC SYSTEM PER Valuation: $ 0.00 Tenant
APPROVED PLANS.HERS REQUIRED FOR FINAL
Total Sq Feet: 0.00 Plan Check# Plan#
Fees Amount Payments Amount Paid
Bathtubs/or Combo $13.21 Total Fees $906.87
Bidet $26.42 Cash/Receipt#REC-03469-19 $906.87
Clothes Washer $13.21
Compressor 3-5 Ton(3 to 15 hp) $36.35 Amount Due: $0.00
Dishwasher $13.21
Electrical Permit Issuance Fee $47.01 1/7/:, G �Furnace or Burner<=100,000 BTU $19.86 i1
Garbage Disposal Fee $13.21
Gas System(Outlets) $62.20
Hood Serviced by Mechanical Exhaust $14.96
Kitchen Sink $13.21 CALLS FOR INSPECTIONS
Laundry Trays $13.21 Request for inspection by telephone at 626-574-5450. Leave a message
Lavatories $105.68 requesting the address,timeframe and what inspection item is needed.
Mechanical Permit Issuance Fee $47.01
Motors,Generators<1 hp $8.07
New Residential Accessory Bldg (sq ft $31.22 This permit/plan review expires by time limitation and becomes null and
area) void if the work authorized by the permit is not commenced within 180 days
New Residential Elect.(sq ft area) $174.88 from the date of issuance or if the permit is not obtained within 180 days
Plumbing Permit Issuance Fee $47.01 from the date of plan submittal.This permit expires and becomes null and
Residential Services up to 400 amps $16.48 void if any work authorized by this permit is suspended or abandoned for 180
Sewer Connection on Property $33.01 consecutive days or if no progressive work has been verified by a City of
Shower $26.42 Arcadia building inspector for a period of 180 consecutive days.
Total: $906.87
COMPLE9
December 27, 2019
Issued By: Date
December 27,2019 Page 1 of 1
•
7
41 ! PERMIT/PLAN REVIEW APPLICATION ' •
•4
Epp' Development Services Department,240 West Huntington Drive,Post Office Box 60021
� .of Arcadia, CA 91066-6021, (626) 574-5416,Fax(626) 447-9173
City of
Arcadia
LICENSED CONTRACTOR'S DECLARATION WORKERS'COMPENSATION DECLARATION
❑ I hereby affirm under penalty of perjury that I am licensed under provisions of I hereby affirm under penalty of perjury one of the following:
Chapter 9(commencing with Section 7000,of Division 3 of the Business and
Professions Code,and my license is in full force and effect. 0 I have and will maintain a certificate of consent to self-insure for workers'
License Class License No. Exp. Date compensation, as provided for by Section 3700 of the Labor Code, for the
performance of the work for which this permit is issued.
Signature of Contractor Q Cy
gli. OWNER-BUILDER DECLARATION IDI have and will maintain workers'compensation insurance,as required by Section
hereby affirm under penalty of perjury that I am exempt from the Contractors 3700 of the Labor Code,for the performance of the work for which this permit
L r Law for the following reason(Section 7031.5,Business and Professions is issued.My workers'compensation insurance carrier and policy numbers are:
Code.Any city or county which requires a permit to construct,alter,improve, Carrier
demolish,or repair any structure,prior to its issuance,also required the applicant
for such permit to file a signed statement that he or she is licensed pursuant to the Policy Number
provisions of the Contractors License Law(Chapter 9(commencing with Section (This section need not be completed if the permit is for one hundred dollars or less)
7000)of Division 3 of the Business and Professions Code)or that he or she is
exempt there from and the basis for the alleged exemption. Any violation of ❑ I certify that in the performance of the work for which this permit is issued,I shall
Section 7031.5 by any applicant for a permit subjects the applicant to a civil not employ any person in any manner so as to become subject to the workers'
penalty of not more than five hundred dollars($500)): compensation Laws of California,and agree that if I should become subject to the
workers'compensation provisions of Section 3700 of the Labor Code,I shall
❑I, as owner of the property, or my employees with wages as their sole forthwith co y wi those provisi
compensation,will do the work,and the structure is not intended or offered for
sale(Section 7044,Business and Professions Code:The Contractors License Date /� (ii Signature Law does not apply to an owner of property who builds or improves thereon,
or who does such work himself or herself or through his or her own
employees,provided that such improvements are not intended or offered for WARNING: Failure to secure Workers'Compensation coverage is unlawful,
sale.If,however,the building or improvement is sold within one(1)year of and shall subject an employer to criminal penalties and civil fines up to one
completion,the owner-builder will have the burden of proving that he or she hundred thousand dollars($100,000),in addition to the cost of compensation,
did not build or improve for the purpose of sale). damages as provided for in Section 3706 of the Labor Code, interest, and
attorney's fees.
❑I, as owner of the property, am exclusively contracting with licensed
contractors to construct the project(Section 7044, Business and Professions
Code:The Contractors License Law does not apply to an owner of property CONSTRUCTION LENDING AGENCY
who builds or improves thereon,and who contracts for such projects with a I hereby affirm under penalty of perjury that there is a construction lending agency
contractor(s)licensed pursuant to the Contractors License Law). for the performance of the work for which this permit is issued (Section 3097,
Civil Code).
❑ I am exempt under Section 7044,Business and Professions Code,for this reason:
Lender's Name
Date /(//i7A Signature � /7 Lender's Address
IMPORTANT: APPLICATION IS HEREBY MADE TO THE BUILDING OFFICIAL FOR A PERMIT SUBJECT TO THE CONDITIONS AND
RESTRICTIONS SET FORTH ON THIS APPLICATION AND THE FOLLOWING:
1. The City's approved plans and permit inspection card must remain on the job site for use by City inspection personnel.
2. Final inspection of the work authori±bd by this permit is required.A Certificate of Occupancy must be obtained prior to use and occupancy of new buildings
and structures.
3. Per South Coast Air Quality Management District(AQMD)regulations,renovation and remodeling work that results in the removal,stripping,or altering
of asbestos containing materials requires an asbestos survey and removal prior to disturbing the asbestos.Please contact AQMD at(909)396-2000 for
further information.
Name / Title ` �
P NAME
I certify that I have read this application and state that the above information is correct and that I am the owner or duly authorized agent of the owner.
I agree to comply with all City ordinances and State Laws relating to building construction. I hereby authorize representatives of the City of
Arcadia to enter upon the above-mentioned property for inspection purposes.
-- _ ��/) //'
Signature • Date
11( •ption
1 •ne
CONSULTING ENGINEERS
PAGE 1 OF 1
STRUCTURAL OBSERVATION REPORT
CITY of ARCADIA
THIS REPORT INCLUDES ALL CONSTRUCTION WORK THROUGH THE: April 1, 2020
PROJECT , "Essex"-SFD OPTION ONE J.N. . 0918-2286
LOCATION , Arcadia,California BLDG.PERMIT NUMBER Mnew-18-1960
OWNER , Lennar Homes LOCATION/DIVISION Coastal
ARCHITECT Angeleno ARCHITECT J.N. 1704
STRUCT.OBS.OF RECORD Ilia Sarad,P.E.,S.E.,S.E.C.B. LIC.OR REGISTRATION No. S-3855
STRUCTURAL OBSERVER Erik Torres,E.I.T. LIC.OR REGISTRATION No.
OBSERVED STRUCTURAL ELEMENTS&THEIR CONNECTIONS: LOT(S)&PHASE OBSERVED:
Interior and Exterior General Framing;i.e.,roof trusses,roof sheathing, Phase:18. Tract:77121
shear elements,holdowns,floor sheathing,floor trusses,beams,headers,and HS#8,Plan 2A
general hardware. 2614 Durham Court
Arcadia,California 91007
OBSERVED DEFICIENCIES: (ATTACH ADDITIONAL PAGES IF NECESSARY) Initial/Completion Date
The deficiencies noted during the observation visit have been corrected and/or installed
by a collaborated effort of the foreman and project superintendent. E.T 04/01/20
Construction Stage: HVAC ❑x ElectricalJ Plumbing ❑Double Sided ❑ Plywood Gig Deck Option Guard
N/A Shear Walls Lid(s) Rails
Note:When box is checked,it indicates that construction stage is in progress,and it has not yet been completed at the time of observation was conducted
❑x STRUCTURAL SYSTEM WAS VISUALLY OBSERVED TO BE IN GENERAL CONFORMANCE WITH THE APPROVED PLANS
STRUCTURAL DEFICIENCIES ARE OF A MINOR NATURE&MAY BE REVIEWED BY CITY BLDG INSPECTOR FOR COMPLIANCE
I DECLARE THAT THE FOLLOWING STATEMENTS ARE TRUE TO THE BEST OF MY KNOWLEDGE AND BELIEF
1. IAM THE REGISTERED ENGINEER WHO HAS RESPONSIBLE CHARGE FOR THE
STRUCTURAL OBSERVATION. QRBFESS fpp.�,,�
2. I,OR ANOTHER QUALIFIED-CHARGE OBSERVER WHO I HAVE DESIGNATED 0 "ye
ABOVE AND IS UNDER MY RESPONSIBLE CHARGE,HAS PERFORMED THE LOYp, ' S4,012
q p9oyc
REQUIRED SITE VISITS AT EACH SIGNIFICANT CONSTRUCTION STAGE TO
VERIFY IF THE STRUCTURE IS IN GENERAL CONFORMANCE WITH THE
APPROVED PLANS AND SPECIFICATIONS. tr
NO. S 3855 7D
3. ALL DEFICIENCIES,WHICH I DOCUMENTED,HAVE BEEN CORRECTED UNLESS
OTHERWISE INDICATED ABOVE. xExp. 3/31/2022
4. ALL OBSERVED DEFICIENCIES SHALL BE CORRECTED AND APPROVED BY THE
OBSERVER PRIOR TO FINAL ACCEPTANCE OF THE STRUCTURAL SYSTEMS BY `�qr rR UC j�RP�a�
THE BUILDING DEPARTMENT. F OF CAl.‘F
5. THIS REPORT IS PROVIDED TO THE OWNER AS A PART OF THE OWNERS
OVERALL CONSTRUCTION QUALITY CONTROL PROGRAM. April 1,2020
6. OPTION ONE HAS PROVIDED STRUCTU' ' OBSERVATION IN ACCORDANCE
WITH THE SEAOC RECO 4` ENDED GUI ELI, I• THE PRACTICE OF STAMP OF ENGINEER-OF-RECORD
STRUCTURAL ENG " Grr IA.
SIGNED BY: 411 .441011111� April I,2020
Ilia Sarad,P.E., ".E.,5.=C.B.
STRUCTURAL OBSERVA ION a IES NOT WAIVE THE REQUIREMENTS FOR INSPECTIONS BY CITY BUILDING
INSPECTORS. ALL WORK MU' ' PLY WITH THE APPROVED PLANS AND APPLICABLE STATE&LOCAL CODES.
228650R_frmg_H58_P2A
Option One Tel 714.556.1916
Consulting Engineers 2755 Bristol Street, Suite 100, Costa Mesa, Ca. 92626 Fax 714.556.1952
-11
City of Arcadia, CA Permit NO. SOLR-20-0460
Development Services Department Permit Type:Solar
240 West Huntington Drive,Post Office Box 60021
Arcadia,CA 91066-6021 Work Classification:Solar-Residential
(626)574-5416 Permit Status:Issued
ARCADIA Issue Date:04/15/2020 Expiration: 10/12/2020
Addr NO. Dir Prefix Street Name Street Suffix Unit City,State,Zip Parcel Number
2614 DURHAM ARCADIA, CA 91006 5788020031
-iiiimmonommairte . .a „
Contacts
LENNAR HOMES OF CALIFORNIA* Contractor
15131 ALTON PKWY 365,Irvine,CA 92618
(949)349-8215 728102
Description:ROOF MOUNTED SOLAR SYSTEM 9 Valuation: $ 0.00 Tenant
MODULES/MICROINVERTERS SYSTEM SIZE 2.88 KW
Total Sq Feet: 0.00 Plan Check#20-460 Plan q
Fees Amount Payments Amount Paid
Building Plan Check Fee Residential $50.00 Total Fees $308.24
Electrical Permit Issuance Fee $47.01 Cash/Receipt U REC-04272-20 $308.24
Fire Plan Check Fee Residential $50.00
Amount Due: $0.00
Inverters $77.78
Panels $82.45
Solid Waste Management Fee 2 $1.00
Total: $308.24
€1-27-2-0 gi •e`•• ••
CALLS FOR INSPECTIONS
Request for inspection by telephone at 626-574-5450. Leave a message
8 4/2-2.0 /�---A144, � -sw..� requesting the address,timeframe and what inspection item is needed.
This permit/plan review expires by time limitation and becomes null and
void if the work authorized by the permit is not commenced within 180 days
from the date of issuance or if the permit is not obtained within 180 days
from the date of plan submittal.This permit expires and becomes null and
void if any work authorized by this permit is suspended or abandoned for 180
consecutive days or if no progressive work has been verified by a City of
Arcadia building inspector for a period of 180 consecutive days.
o IILE1
D
April 15, 2020
Issued By: Date
April 15,2020 Page 1 of 1
F AR
kA
! PERMIT/PLAN REVIEW APPLICATION
{#*' Development Services Department,240 West Huntington Drive,Post Office Box 60021
/e Arcadia, CA 91066-6021, (626)574-5416,Fax(626) 447-9173
City of
Arcadia
LICENSED CONTRACTOR'S DECLARATION WORKERS'COMPENSATION DECLARATION
❑ I hereby affirm under penalty of perjury that I am licensed under provisions of I hereby affirm under penalty of perjury one of the following:
Chapter 9(commencing with Section 7000,of Division 3 of the Business and
Professions Code,and my license is in full force and effect. 0 I have and will maintain a certificate of consent to self-insure for workers'
License Class License No. Exp. Date compensation, as provided for by Section 3700 of the Labor Code, for the
performance of the work for which this permit is issued.
Signature of Contractor
OWNER-BUILDER DECLARATION ❑ I have and will maintain workers'compensation insurance,as required by Section
❑ I hereby affirm under penalty of perjury that I am exempt from the Contractors 3700 of the Labor Code,for the performance of the work for which this permit
License Law for the following reason(Section 7031.5,Business and Professions is issued.My workers'compensation insurance carrier and policy numbers are:
Code.Any city or county which requires a permit to construct,alter,improve, Carrier
demolish,or repair any structure,prior to its issuance,also required the applicant
for such permit to file a signed statement that he or she is licensed pursuant to the Policy Number
provisions of the Contractors License Law(Chapter 9(commencing with Section (This section need not be completed if the permit is for one hundred dollars or less)
7000)of Division 3 of the Business and Professions Code)or that he or she is
exempt there from and the basis for the alleged exemption. Any violation of 0 I certify that in the performance of the work for which this permit is issued,I shall
Section 7031.5 by any applicant for a permit subjects the applicant to a civil not employ any person in any manner so as to become subject to the workers'
penalty of not more than five hundred dollars($500)): compensation Laws of California,and agree that if I should become subject to the
workers'compensation provisions of Section 3700 of the Labor Code,I shall
❑I, as owner of the property, or my employees with wages as their sole forthwith comply with those provisions.
compensation,will do the work,and the structure is not intended or offered for
sale(Section 7044,Business and Professions Code:The Contractors License Date Signature
Law does not apply to an owner of property who builds or improves thereon,
or who does such work himself or herself or through his or her own
employees,provided that such improvements are not intended or offered for WARNING: Failure to secure Workers'Compensation coverage is unlawful,
sale.If,however,the building or improvement is sold within one(1)year of and shall subject an employer to criminal penalties and civil fines up to one
completion,the owner-builder will have the burden of proving that he or she hundred thousand dollars($100,000),in addition to the cost of compensation,
did not build or improve for the purpose of sale). damages as provided for in Section 3706 of the Labor Code, interest, and
attorney's fees.
❑I, as owner of the property, am exclusively contracting with licensed
contractors to construct the project(Section 7044,Business and Professions
Code:The Contractors License Law does not apply to an owner of property CONSTRUCTION LENDING AGENCY
who builds or improves thereon,and who contracts for such projects with a I hereby affirm under penalty of perjury that there is a construction lending agency
contractor(s)licensed pursuant to the Contractors License Law). for the performance of the work for which this permit is issued (Section 3097,
Civil Code).
0 I am exempt under Section 7044,Business and Professions Code,for this reason:
Lender's Name
Date Signature Lender's Address
IMPORTANT: APPLICATION IS HEREBY MADE TO THE BUILDING OFFICIAL FOR A PERMIT SUBJECT TO THE CONDITIONS AND
RESTRICTIONS SET FORTH ON THIS APPLICATION AND THE FOLLOWING:
1. The City's approved plans and permit inspection card must remain on the job site for use by City inspection personnel.
2. Final inspection of the work authorized by this permit is required.A Certificate of Occupancy must be obtained prior to use and occupancy of new buildings
and structures.
3. Per South Coast Air Quality Management District(AQMD)regulations,renovation and remodeling work that results in the removal,stripping,or altering
of asbestos containing materials requires an asbestos survey and removal prior to disturbing the asbestos. Please contact AQMD at(909)396-2000 for
further information.
Name Title
PRINT NAME
I certify that I have read this application and state that the above information is correct and that I am the owner or duly authorized agent of the owner.
I agree to comply with all City ordinances and State Laws relating to building construction. I hereby authorize representatives of the City of
Arcadia to enter upon the above-mentioned property for inspection purposes.
Signature Date ___
.f,
PERMIT/PLAN REVIEW APPLICATION
Development Services Department, 240 West Huntington Drive, Post Office Box 60021
I Arcadia, CA 91066-6021, (626) 574-5416, Fax (626) 447-9173
---- r- ONLINE PERIIIIT/PLAN RE\'IEWV APPLICATION
II',Ul
ARC.'ADIA Job Site Address: 71,ill DE/rhe/Th
LICENSED CONTRACTOR'S DECLARATION WORKERS'COMPENSATION DECLARATION
WI hereby a0irm under penalty of perjury that I am licensed under provisions of I hereby affirm under penalty of perjury one of the following.
Chapter 9(commencing with Section 7000,of Division 3 of the Business and
Professions Code,and my license is in full force and effect. ❑ 1 have and will maintain a certificate of consent to self-insure for workers'
License Class Li . / p Date compensation, as provided for by Section 3700 of the Labor Code, for the
performance of the work for which this permit is issued
Signature of Contractor
OWNER-BUILDER DECLARATION k'a, I have and will maintain workers'compensation insurance,as required by Section
0 I hereby affirm under penalty of perjury that I am exempt from the Contractors 3700 of the Labor Code.for the performance of the work for which this permit
is issued My workers'compensation insurance carrier and policy numbers ere
License Law for the following reason(Section 7031.5,Business and Professions
Code.Any city or county which requires a permit to construct, alter,improve. Carrier
demolish,or repair any structure.prior to its issuance.also required the applicant P f / ‘
for such permit to file a signed statement that he or she is licensed pursuant to the Policy Number
provisions of the Contractors License Law(Chapter 9(commencing with Section (This section need not be completed if the permit is for one hundred dollars or Ices)
7000)of Division 3 of the Business and Professions Code)or that he or she is
exempt there from and the basis for the alleged exemption. Any violation of ❑ I certify that in the performance of the work for which this permit is issued.I shall
Section 7031.5 by any applicant for a permit subjects the applicant to a civil not employ any person in any manner so as to become subject to the workers
penalty of not more than five hundred dollars(5500)) compensation Laws of California.and agree that if I should become subject to the
workers'compensation provisions of Section 3700 of the Labor Code.I shall
❑ or 1, as owner of the property, or my employees with wages as their sole foithwithcomplywiththoseprovisions /�
compensation,will do the work,and the structure is not intendedoffered for
sale(Section 7044. Business and Professions Code:The Contractors License Date Signature
Law does not apply to an owner of property who builds or improves thereon,
or who does such work himself or herself or through his or her own
employees, provided that such improvements are not intended or offered for WARNING. Failure to secure Workers'Compensation coverage is unlawful,
sale. If,however,the building or improvement is sold within one(I)year of and shall subject an employer to criminal penalties and civil fines up to one
completion.the owner-builder will have the burden of proving that he or she hundred thousand dollars($100.000),in addition to the cost of compensation,
did not build or improve for the purpose of sale). damages as provided for in Section 3706 of the Labor Code, interest. and
attorney's fees
❑I. as owner of the property, am exclusively contracting with licensed
contractors to construct the project (Section 7044,Business and Professions
Code:The Contractors License Law does not apply to an owner of property CONSTRUCTION LENDING AGENCY
who builds or improves thereon.and who contracts for such projects with a I hereby affirm under penalty of perjury that there is a construction lending agency
contractor(s)licensed pursuant to the Contractors License Law). for the performance of the work for which this permit is issued (Section 3097.
Civil Code).
❑ I am exempt under Section 7044.Business and Professions Code,for this reason.
Lender's Name
Date Signature Lender's Address
IMPORTANT: 11'1'1.1('%1101 IS IIERIItI SlAlil: TO -flip. lit 11.1)1\(. (1111('1.11 Hilt 1 l'l•:10111 St 11.11('1 lir 1111 i O\1)II10\' \\It
KESTKI(-1IONS SEI. FUR IIIt)\ IIIlS.11'PI.I('AIION \NI)1111.IUI11)11111,:
I. The City's approved plans and permit inspection card must remain on the job site for use by City inspection personnel.
2. Final inspection of the work authorized by this permit is required A Certificate of Occupancy must be obtained prior to use and occupancy of new buildings
and structures
3. Per South Coast Air Quality Management District (AQMD)regulations,renovation and remodeling work that results in the removal,stripping,or altering
of asbestos containing materials requires an asbestos survey and removal prior to disturbing the asbestos. Please contact AQMD at(909)396.2000 for
further information.
Name Title
PRINT NAME
I certify that I have read this application and state that the above information is correct and that I am the owner or duly authorized agent of the owner.
I agree to comply with all City ordinances and State Laws relating to building construction. I hereby authorize representatives of the City of
Arcadia to enter upon the above-mentioned property for inspection purposes.
..---
Signature c... //- ----. 5ti Date /147g10
t4
11 Option
One
CONSUL TING ENGINEERS
PAGE 1 OF 1
STRUCTURAL OBSERVATION REPORT
LENNAR HOMES, CA
THIS REPORT INCLUDES ALL CONSTRUCTION WORK THROUGH THE: February 13, 2020
PROJECT , "Essex"-SFD OPTION ONE J.N. 0918-2286
LOCATION , Arcadia,California BLDG.PERMIT NUMBER Mnew-18-1960
OWNER , Lennar Homes LOCATION/DIVISION Coastal
ARCHITECT , Angeleno ARCHITECT J.N. 1704
STRUCT.OBS.OF RECORD , Ilia Sarad,P.E.,S.E.,S.E.C.B. LIC.OR REGISTRATION No. S-3855
STRUCTURAL OBSERVER Erik Torres LIC.OR REGISTRATION No.
OBSERVED STRUCTURAL ELEMENTS&THEIR CONNECTIONS: LOT(S)&PHASE OBSERVED:
Conventional Foundation System;i.e.,anchor bolts,holdown bolts&straps, Phase:1B, Tract:77121
post bases,Strong-Wall/Hardy Frame anchor bolts,slab size/reinforcement and HS#8,Plan 2A
footing&pad size/reinforcement(NOTE:monolithic pour system). - 2614 Durham Court
Arcadia,Califomia 91007
OBSERVED DEFICIENCIES: (ATTACH ADDITIONAL PAGES IFNECESSARY)_ . . _ Initial/Completion Date
The deficiencies noted during the observation visit have been corrected and/or installed
by a collaborated effort of the foreman and project superintendent E T. 02/13/20
Construction Stage: ri ri Double Sided n Plywood CPgGuard
HVAC Electrical Plumbing u Deck Option u
N/A Shear Walls Lid(e) Rails
Note:When box is checked,it indicates that construction stage is in progress,and it has not yet been completed at the time of observation was conducted
0 STRUCTURAL SYSTEM WAS VISUALLY OBSERVED TO BE IN GENERAL CONFORMANCE WITH THE APPROVED PLANS
STRUCTURAL DEFICIENCIES ARE OF A MINOR NATURE&MAY BE REVIEWED BY CITY BLDG INSPECTOR FOR COMPLIANCE
I DECLARE THAT THE FOLLOWING STATEMENTS ARE TRUE TO THE BEST OF MY KNOWLEDGE AND BELIEF
1. I AM THE REGISTERED ENGINEER WHO HAS RESPONSIBLE CHARGE FOR THE
STRUCTURAL OBSERVATION. ELOEESSfp,�
2. I,OR ANOTHER QUALIFIED-CHARGE OBSERVER WHO I HAVE DESIGNATED Q
ABOVE AND IS UNDER MY RESPONSIBLE CHARGE,HAS PERFORMED THE ��4,„ \I 9� S4 p <4
REQUIRED SITE VISITS AT EACH SIGNIFICANT CONSTRUCTION STAGE TO
VERIFY IF THE STRUCTURE IS IN GENERAL CONFORMANCE WITH THE tsrn
APPROVED PLANS AND SPECIFICATIONS.
NO. S 3855 211
3. ALL DEFICIENCIES,WHICH I DOCUMENTED,HAVE BEEN CORRECTED UNLESS
OTHERWISE INDICATED ABOVE. * Exp. 3/31/2020
4. ALL OBSERVED DEFICIENCIES SHALL BE CORRECTED AND APPROVED BY THE
OBSERVER PRIOR TO FINAL ACCEPTANCE OF THE STRUCTURAL SYSTEMS BY �9T T RU C T F•
OBSERVER
THE BUILDING DEPARTMENT. OF cA`1F0
5. THIS REPORT IS PROVIDED TO THE OWNER AS A PART OF THE OWNERS
OVERALL CONSTRUCTION QUALITY CONTROL PROGRAM. February 13,2020
6. OPTION ONE HAS PROVIDED STRUCTURAL OBSERVATION IN ACCORDANCE
WITH THE SEAOC RECO 6. ENDED GUIDELINES FOR THE PRACTICE OF STAMP OF ENGINEER-OF-RECORD
STRUCTURAL ENGINE r" G .40 IFO' IA.
SIGNED BY: February 13,2020
Illa Sa ad,P.E.,S...,S.E. .B.
STRUCTURAL OBSERVA ON DO:. NOT WAIVE THE REQUIREMENTS FOR INSPECTIONS BY CITY BUILDING
INSPECTORS. ALL WORK MU COM LY WITH THE APPROVED PLANS AND APPLICABLE STATE&LOCAL CODES.
2286508 Foundation H58 P2A
Option One Tel 714.556.1916
Consulting Engineers 2755 Bristol Street. Suite 100, Costa Mesa, Ca. 92626 Fax 714.556.1952
40-
SCOPE
SCOPE OF WORK LEGEND AND ABBREVIATIONS TABLE OF CONTENTS
BUYER ACKNOWLEDGES THAT THE SOLAR PAGE DESCRIPTION
MODULES TO BE INSTALLED PITCH TRUE AZIM MOD COUNT SERVICE ENTRANCE SOLAR MODULES #
ON THE ROOF OF THE HOME WILL BE h �r RAIL
SUBSTANTIALLY IN THE ARRAY 1 21° 270° 7 MP MAIN PANEL 1 PV-G SITE PLAN
LOCATIONS INDICATED BY THE ILLUSTRATION.
ARRAY 2 21° 270° 2 SP SUB-PANEL / PV-A LAYOUT
BUYER(S): L STANDOFFS 8
PLAN 2 ELEVATION A STANDARD Lc PV LOAD CENTER FOOTINGS PV-E I ELECTRICAL
DATE: CHIMNEY
ORIENTATION 2 LOT#08 OM DEDICATED PV METER PV-E II SIGNAGE
ATTIC VENT
INVERTER(S)WITH • SYSTEM SIZE:2.880 kW
INV INTEGRATED DC I= FLUSH ATTIC VENT • MODULES:(9)LG320NIK-V5
DISCONNECT AND AFCI 0 PVC PIPE VENT 320W
SITE PLAN-SCALE= 1/64"-1'-0" 0 AC DISCONNECT(S) ® (320W)• INVERTER(S):(9)ENPHASE
/\ METAL PIPE VENT IQ 7+
DC DC DISCONNECT(S) IS) T-VENT
SNI • ROOF TYPE:TILE W/COMP
CB Q SATELLITE DISH SHINGLE AT ARRAY
n COMBINER BOX -
+� FIRE SETBACKS
F BATTERY
• q, HARDSCAPE
lee
a :� aT AT AUTOTRANSFORMER -PL- PROPERTY LINE
r OPM00.1 1.1E.
BP BACKED UP LOADS r -1 BACKED EQUIPMENT
_ _ lu I �5-`k� J _ _ /hit _ O PANEL I0 SHOWN AS DASHED
ir
FFA 357.7 Ii-
PM-357 Q
2 __ • /IT Hi SUNSTREET
ui 11. .. L jzi�� - SCALE NTS
--moi *VT , 8EIGHTY
mom A AMPERE
FFA 357.4 13 14 15 16 AC ALTERNATING CURRENT
,e F 57' AFCI ARC FAULT CIRCUIT INTERRUPTER
: AZIM AZIMUTH
LENNAR.DIVISION ADDRESS
)— 1�- o n 4 D COMPCOMPOSITION PHONE
4 > DCCC
DIRECT CURRENT FAX
(E) EXISTING
' FT 357.1 ..\rN.� te EXT FRM FRAMING
CUSTOMER RESIDENCE:
Pte•, e� 2614 DURHAM COURT
INT INTERIOR
LBW LOAD BEARING WALL ARCADIA,CA 91007
qn, i MAG MAGNETIC
0� � /Afk --t_-,r,--1 MSP MAIN SERVICE PANEL TEL TMK#
(N) NEW
• SS sr NTS NOT TO SCALE PROJECT NUMBER
FF- 356.0 OC ON CENTER PROJ0109200
"� %% PAD.3SS3 PRE-FAB PRE-FABRICATED
9 =7-' F DESIGNER:NOE FLORES
PSF POUNDS PER SQUARE FOOT
__
_ 41 40 39 38 37 PV PHOTOVOLTAICTRAPH#:303-723-7261
f ��, FFA 356.E
/... .;
PAD�7561 ., TL
WATTS
SFORMERLESS
I I J I^a 1 ���r TYP TYPICAL DRAFTER:NOE FLORES
V VOLTS
W WATTS SHEET
' .;A `I d-i 6 \'-9 / io °ti�+ 72\it
COVER SHEET
REV NAME DATE COMMENTS
�! REV:A 3/31/2020
,ktimstmcroPELL
`' ` /`_$_ A PAGE PV—G
SYSTEM LAYOUT-SCALE=3/32"-1'-0' • SYSTEM SIZE:2.880 kW
• MODULES:(9)LG320NIK-V5
(320W)
�j FIRE SETBACKS • INVERTER(S):(9)ENPHASE
IQ 7+
(N) PROPERTY LINE (3'TYP)
• ROOF TYPE:TILE W/COMP
FIRE SETBACKS SHINGLE AT ARRAY
(N) RESIDENCE — (18"TYP)
0. 0. R 0. R R R . ..
F
/ws
•
•
• 1111
C "
JI• •
•w • ,Xw
F • s•. •i fi
"1111 " /••
•
(N)ARRAY AR 01 `•" "•� "" (N) FOOT
�. w • •
• ••f
ass ••w"./ to:�r
F , • • •, ' ;;;; (N) RAIL
•W w••w
11
(N)ARRAY AR-02 • zoo' "oil"••11.111r "oil
,posfox
.11 "• 0111:ilt1 •11" ••••
F "1111" 1111•.
..... •... n SUNSTREET
AC •••• •. - - , •••• 8EIGHTY
SSE :.:"`::w•• ••••
CB "• •41,'; :: --T :1111•
• 4111::::
LENNARDIVISIONADDRESS
1=1 411 III PHONE:
J /•• !. 1 •• FAX
w• " "• ••••
C.) ,!w • • • "1111"
A• •s" • s "1111"
F ,l::"•:v _ •"•"1111 : •I CI :::: CUSTOMER RESIDENCE
�� I I I I I ""11"1111•
2614 DURHAM COURT
• ARCADIA,CA 91007
TEL. TMK#
F
(N) DRIVEWAY PROJECT NUMBER:
PROJ0109200
DESIGNER:NOE FLORES
w a a a a a PH#:303-723-7261
DRAFTER:NOE FLORES
'-9'-10"—'-6'-8"— —9'-10"— ' 10' r— 3'
1'-4" SHEET
T-5" _ 10'-9"
FLASHING FLASHING—/ LAYOUT
REV:A 3/31/2020
V PAGE PV-A
lir
i 120/240 VAC
SINGLE PHASE
SERVICE
l\ METER#1UTILITY O
GRID
NEW 200 A
MAIN
BREAKER (N)60A ENPHASE •MAX 13 MICRO-INVERTERS PER BRANCH CIRCUIT
AC COMBINER BOX •MULTIPLE BRANCH CIRCUITS IN PARALLEL
20A PV BREAKERS WITH •ENPHASE MULTI-PIN CONNECTORS-1ST AC CONNECTOR AT
NEW 10A ENVOY BREAKER EACH BRANCH CIRCUIT IS A SUITABLE DISCONNECTING MEANS.
< 200A (N)LOCKABLE •DO NOT DISCONNECT/CONNECT UNDER LOAD
MAIN BLADE TYPE _
FACILITY PANEL 3 AC DISCONNECT 3 JUNCTION BOX p qqq
LOADS - /� 2 OR EOUNALENT 1 may-, I ()
n TRFT.I
1 BRANCH OF
„o Vt ® J ® v V I (9)MICRO-INVERTERS
tt I
20A PV •1•=7, SQUARE D
BREAKER AT DU222RB
OPPOSITE END 3R.60A,2P
OF BUSBAR 120240VAC
SYSTEM SIZE OPTION CONDUIT SCHEDULE
MODULE POWER SYSTEM SIZE(kW # CONDUCTOR WIRE TYPE TYPE LOCATION TRADE
OPTION MODULE QTY. (WATTS DC) DC @STC) 1 1#12 ENPHASE Q CABLE, CU UL3003,DG ARRAY SOLAR
146G,FREE AIR CABLE
A 9 320 2.88 2 3410,1-#10 EGC CU NM-B(ROMEX) INTERIOR SOLAR
3 3-#10,1410 EGC CU NM-B(ROMEX) INTERIOR SOLAR
CONDUCTOR SIZING CALCULATIONS
1)CONDITION OF USE(COU): (AMPACITY'TEMP.DERATE'FILL DERATE)vs.REQ'D(IMA,) INTERCONNECTION CALCULATIONS
2)TERMINALS(TERM): AMPACITY AT TERMINALS.vs.REQ'D,(IMAX'1.25)
KEY SIZE CU/AL INSULATION CALC. AMPACITY W/O TEMP. FILL RESULT REQ'D OCD ITEM UNIT PANEL
TYPE DEBATES DERATE DERATE (A) (A) USED(A) PANEL MANUFACTURER CUTLER HAMMER 101 SUNSTREET
1 #12 CU THWN-2 COU 30 0.76 1.00 22.80 1098
TERM 25 25.00 12.10 20.00 BUS RATING AMPS 200
8EIGHTY
2 #10 CU NM-B COU 40 0.91 1.00 36.40 10.98 MAIN DISCONNECT AMPS 200
TERM 35 35.00 12.00 20.00
3 #10 CU NM-B COU 40 1.00 1.00 36.00 10.00 ALLOWED PV PER NEC AMPS 40
TERM 35 35.00 12.00 20.00 PV OCPD USED AMPS 20 LENNAR:DIVISION ADDRESS
PHONE.
FAX
MODULE SPECIFICATION AND CALCULATIONS INVERTER SPECIFICATIONS AND CALCULATIONS
ITEM NOTE/CALCULATION UNIT DETAIL ITEM NOTE/CALCULATION UNIT DETAIL CUSTOMER RESIDENCE'
LOCATION ARCADIA.CA INVERTER MAKE INVERTER SPEC ENPHASE 2614 DURHAM COURT
TEMP.AMBIENT HIGHT(T neo( ASHRAE 2% °C 31INVERTER MODEL INVERTER SPEC °C IQ7PLUS-72-2-US ARCADIA,CA 91007
TEMP,AMBIENT LOW(Turin) ASHRAE EXTREME MIN -0 -2
INVERTER MAX POWER(Wac MAX) INVERTER SPEC WATTS(AC) 295
TEMP,MODULE TEST(Ttest) MODULE SPEC 'C 25 JUL. TMK B
TEMP,DELTA LOW(Tdefla) Tnin-Ttest 'C -27 INVERTER INPUT VOLTAGE(Voc MAX) INVERTER SPEC VOLTS(DC) 60 PROJECT NUMBER.
MODULE MANUFACTURER MODULE SPEC LG INVERTER OUTPUT VOLTAGE(Vac NOM) INVERTER SPEC VOLTS(AC) 240 PROJ0109200
MODULE PART NUMBER MODULE SPEC LG320N1K-V5(320W) INVERTER OUTPUT FREQUENCY INVERTER SPEC HERTZ 60
DESIGNER:NOE FLORES
MODULE POWER STC(P) MODULE SPEC WATTS(DC) 320 INVERTER OUTPUT CURRENT(lac) INVERTER SPEC AMPS(AC) 1.21
PH#:303-723-7261
MODULE OPERATING VOLTAGE(VMP) MODULE SPEC VOLTS(DC) 33.3
INVERTER PHASE QUANTITY INVERTER SPEC PHASE 1 -
MODULE OPEN CIRCUIT VOLTAGE MODULE SPEC VOLTS(DC) 40.8
(VOC) COMPLIACE INVERTER SPEC UL1741/IEEE1547 DRAFTER:NOE FLORES
MODULE COEF.VOLT/TEMP(Cool) MODULE SPEC V/CJ -0.27
INVERTER GROUNDING INVERTER SPEC ISOLATED
MODULE MAX VOLTAGE(Vmacmod) (VOC+(TD'COEF)) VOLTS(DC) 48.09 SHEET
MODULE OPERATING CURRENT(IMP) MODULE SPEC AMPS(DC) 9.62 INVERTER QTY.MAX PER BRANCH MODULE QTYbc QTY 9 ELECTRICAL
MODULE SHORT CIRCUIT CURRENT MODULE SPEC AMPS(DC) 10.19 CIRCUIT
(ISC) BRANCH CIRCUIT OUTPUT(Imaxbc) (IAC'MODULE QTYbc) AMPS(AC) 10.89 REV:A 3/31/2020
' MODULE MAXIMUM CURRENT(IMAX) (ISC'1.25) AMPS(DC) 12.74
INVERTER QTY.TOTAL MODULE QTYt QTY 9 PAGE E 1
MINIMUM AMPACITY REQ'D.PER NEX (IMAX'1.25) AMPS(DC) 15.92
SERIES FUSE RATING.MAX MODULE SPEC AMPS(DC) 20 TOTAL SYSTEM OUTPUT(Imaxis) (IAC'MODULE QTYt) AMPS(AC) 10.89
. ,
■ /WARNING Di. WARNING
, I AUTI N ■
INVERTER OUTPUT CONNECTION DUAL POWER SUPPLY
POWER TO THIS BUILDING IS DO NOT RELOCATE THIS SOURCES: UTILITY GRID
ALSO SUPPLIED FROM THE \ OVERCURRENT DEVICE AND PV SOLAR ELECTRIC
FOLLOWING SOURCES WITH LABEL LOCATION: SYSTEM
ADJACENT ,..
DISCONNECTS AS SHOWN APPLICABLEOPVBREAKER(IF). LABEL LOCATION: l
PER CODE(S):CEC 2016:705.12(D)(2)(3)(b) UTILITY SERVICE METER AND MAIN
SERVICE PANEL.
,N1 ��. . PER CODE(S):CEC 2016:705.12(D)(3)
AC COMBINER BOX /WARNING `
PV AC DISCONNECT
AWA RN I N G
ELECTRICAL SHOCK HAZARD
EXTERIOR
UTILITY METER&
MAIN SERVICE PANEL DO NOT TOUCH TERMINALS. ELECTRICAL SHOCK HAZARD
SOLADECK WIRE TRANSITION d TERMINALS ON LINE AND LOAD IF GROUND FAULT IS INDICATED
BOX (UNDER ARRAY) I SIDES MAY BE ENERGIZED IN ALL NORMALLY GROUNDED
-- THE OPEN POSITION CONDUCTORS MAY BE
== LABEL LOCATION UNGROUNDED AND ENERGIZED
INVERTER(S),AC DISCONNECT(S),AC COMBINER PANEL
(IF APPLICABLE). LABEL LOCATION:
PER CODE(S).CEC 2016:690.17(E) INVERTER(S),ENPHASE ENVOY ENCLOSURE(IF
APPLICABLE).
SOLAR PANELS ON ROOF PER CODE(S):CEC 2016:690.5(C)
PHOTOVOLTAIC AC DISCONNECT
MAXIMUM AC OPERATING CURRENT:10.89 AMPS
SERVICENEONLYBY QUCONTACT'
NOMINAL OPERATING AC VOLTAGE: 240 VAC NNS SUNSTREET
PERSONNEL CONTACT N�
SUNSTREET ENERGY GROUP
1-877-SLR-POWR LABEL LOCATION: 8EIGHTY
AC DISCONNECT(S),PHOTOVOLTAIC SYSTEM POINT OF
INTERCONNECTION.
PHOTOVOLTAIC SYSTEM PER CODES) CEC 2016:690.54
LENNAR.DIVISION ADDRESS
WARNING: PHOTOVOLTAIC FAX PHO
EQUIPPED WITH AC DISCONNECT CUSTOMER RESIDENCE:
2614 DURHAM COURT
RAPI D SHUTDOWN LABEL LOCATION:INTERIOR AND EXTERIOR DC CONDUIT EVERY 10 FT AT EACH TURN,ABOVE AND ARCADIA,CA 91007
BELOW PENETRATIONS.ON EVERY JB/PULL BOX CONTAINING DC CIRCUITS.
PER CODE(S).CEC 2016'690.31)G)(3(,690.31)G))4)
LABEL LOCATION: TEL. TMKi
PER TYCO SERVICE216690 ENTRANCE/METER,OR AS REQUIRED BY LOCAL AHJ. WARNING: P H OTOVO LTA IC
PROJECT NUMBER:
PER CODE(S):CEC 2016:690.12 PROJ0109200
NOTES AND SPECIFICATIONS: POWER SOURCE PH#:303-723-7261 DESIGNER: FLORES
•SIGNS AND LABELS SHALL MEET THE REQUIREMENTS OF THE CEC 2016
AND NEC 2014 ARTICLE 110.21(6),UNLESS SPECIFIC INSTRUCTIONS ARE
REQUIRED BY SECTION 690,OR IF REQUESTED BY THE LOCAL AHJ.
•SIGNS AND LABELS SHALL ADEQUATELY WARN OF HAZARDS USING LABEL LOCATION: DRAFTER:NOE FLORES
EFFECTIVE WORDS,COLORS AND SYMBOLS.
•LABELS SHALL BE PERMANENTLY AFFIXED TO THE EQUIPMENT OR WRING INTERIOR AND EXTERIOR DC CONDUIT EVERY 10 FT,AT EACH TURN,ABOVE AND
METHOD AND SHALL NOT BE HAND WRITTEN,UNLESS PORTIONS OF BELOW PENETRATIONS,ON EVERY JB/PULL BOX CONTAINING DC CIRCUITS. SHEET
LABELS OR MARKINGS ARE VARIABLE,OR THAT COULD BE SUBJECT TO PER CODE(S):CEC 2016:690.31(G)(3),690.31(G)(4)
CHANGES,SHALL BE PERMITTED TO BE HAND WRITTEN AND SHALL BE SIGNAGE
LEGIBLE.
•LABEL SHALL BE OF SUFFICIENT DURABILITY TO WITHSTAND THE
ENVIRONMENT INVOLVED. REV:A 3/31/2020
•SIGNS AND LABELS SHALL COMPLY WITH ANSI Z535.4-2011,PRODUCT
SAFETY SIGNS AND LABELS,UNLESS OTHERWISE SPECIFIED. PAGE E2
•DO NOT COVER EXISTING MANUFACTURER LABELS.