HomeMy WebLinkAboutMNEW-18-1952 •
•
•
City of Arcadia, CA
Permit NO. Mnew-18-1952
• Development Services Department Permit Type:Multi-Family New
240 West Huntington Drive,Post Office Box 60021
Arcadia,CA 91066-6021 Work Classification:MF/New-Detached Condominium
(626)574-5416 Permit Status:Issued
ARCADIA Issue Date:11/26/2019 I Expiration:
Addr NO. Dir Prefix Street Name Street Suffix Unit City,State,Zip Parcel Number
2608 DURHAM CT ARCADIA, CA 91006 5788020031
Contacts
LENNAR HOMES OF CALIFORNIA* Owner LENNAR Applicant
15131 ALTON PKWY 365,Irvine,CA 92618
(949)349-8215
Description:3 BED 2.5 BATH ATTACHED GARAGE PLAN TYPE 1A. Valuation: $ 230,609.26 _ Tenant
PHASE 1
Total Sq Feet: 1.587.00 Plan Check#18-1940 Plan#
- -
Fees Amount Payments Amount Paid
Building Issuing Fee $47.01 Total Fees $11,304.65
Building Permit Fees $2,127.90 Cash/Receipt#REC-002759-2018 $1,181.00
Fire Plan Check $207.48 Cash/Receipt#REC-03193-19 $10,123.65
Green Building Standard $10.00
Park&Recreation(MFR) $5,919.51 Amount Due: $0.00
Plan Check,Per Hour $973.52 '
Single Family/Condo/Townhome Impact $1,983.00
Fee
Solid Waste Management Fee $6.25
Strong Motion Inst.Program Res $29.98
Total: $11,304.65 CALLS FOR INSPECTIONS
Request for inspection by telephone at 626-574-5450. Leave a message
requesting the address,timeframe and what inspection item is needed.
This permit/plan review expires by CA CO MP.l. E y'ull and
void if the work authorized by the permit is not commenced within 180 days
from the date of issuance or if the permit is not obtained within 180 days
from the date of plan submittal.This permit expires and becomes null and
void if any work authorized by this permit is suspended or abandoned for 180
consecutive days or if no progressive work has been verified by a City of
Arcadia building inspector for a period of 180 consecutive days.
November 26, 2019
Issued By: Date
November 26,2019 Page 1 of 1
%F A;
14 !16'±!I PERMIT/PLAN REVIEW APPLICATION
REEF-;.• Development Services Department,240 West Huntington Drive,Post Office Box 60021
•••�ry.(0 Arcadia, CA 91066-6021, (626) 574-5416,Fax (626)447-9173
City of
Arcadia
LICENSED CONTRACTOR'S DECLARATION WORKERS'COMPENSATION DECLARATION
I hereby affirm under penalty of perjury that I am licensed under provisions of I hereby affirm under penalty of perjury one of the following:
Chapter 9(commencing with Section 7000,of Division 3 of the Business and
Professions d my license is in full force and effect. El I have and will maintain a certificate of consent to self-insure for workers'
License Class License No. Exp. Date ,! - compensation, as provided for by Section 3700 of the Labor Code, for the
Signature of Contractor 44 04r— _ performance of the work for which this permit is issued.
OWNER-BUILDER DECLARATION ❑ I have and will maintain workers'compensation insurance,as required by Section
0 I hereby affirm under penalty of perjury that I am exempt from the Contractors 3700 of the Labor Code,for the performance of the work for which this permit
License Law for the following reason(Section 7031.5,Business and Professions is issued.My workers'compensation insurance carrier and policy numbers are:
Code.Any city or county which requires a permit to construct,alter,improve, Carrier
demolish,or repair any structure,prior to its issuance,also required the applicant
Policy Number �N 1
for such permit to file a signed statement that he or she is licensed pursuant to the
provisions of the Contractors License Law(Chapter 9(commencing with Section (This section need not be completed if the permit is for one hundred dollars or less)
7000)of Division 3 of the Business and Professions Code)or that he or she is
exempt there from and the basis for the alleged exemption. Any violation of 0 I certify that in the performance of the work for which this permit is issued,I shall
Section 7031.5 by any applicant for a permit subjects the applicant to a civil not employ any person in any manner so as to become subject to the workers'
penalty of not more than five hundred dollars($500)): compensation Laws of California,and agree that if I should become subject to the
workers'tcomp n7satio provisions of Section 3700 of the Labor Code,I shall
❑I, as owner of the property, or my employees with wages as their sole forthwith co ly wi ose provisions.
compensation,will do the work,and the structure is not intended or offered for
sale(Section 7044,Business and Professions Code:The Contractors License Date / /15 Signature C
Law does not apply to an owner of property who builds or improves thereon,
or who does such work himself or herself or through his or her own
employees,provided that such improvements are not intended or offered for WARNING: Failure to secure Workers'Compensation coverage is unlawful,
sale.If,however,the building or improvement is sold within one(1)year of and shall subject an employer to criminal penalties and civil fines up to one
completion,the owner-builder will have the burden of proving that he or she hundred thousand dollars($100,000),in addition to the cost of compensation,
did not build or improve for the purpose of sale). damages as provided for in Section 3706 of the Labor Code, interest, and
attorney's fees.
❑I, as owner of the property, am exclusively contracting with licensed
contractors to construct the project(Section 7044, Business and Professions
Code:The Contractors License Law does not apply to an owner of property CONSTRUCTION LENDING AGENCY
who builds or improves thereon,and who contracts for such projects with a I hereby affirm under penalty of perjury that there is a construction lending agency
contractor(s)licensed pursuant to the Contractors License Law). for the performance of the work for which this permit is issued (Section 3097,
Civil Code).
0 I am exempt under Section 7044,Business and Professions Code,for this reason:
Lender's Name
Date Signature Lender's Address
IMPORTANT: APPLICATION IS HEREBY MADE TO THE BUILDING OFFICIAL FOR A PERMIT SUBJECT TO THE CONDITIONS AND
RESTRICTIONS SET FORTH ON THIS APPLICATION AND THE FOLLOWING:
1. The City's approved plans and permit inspection card must remain on the job site for use by City inspection personnel.
2. Final inspection of the work authorized by this permit is required.A Certificate of Occupancy must be obtained prior to use and occupancy of new buildings
and structures.
3. Per South Coast Air Quality Management District(AQMD)regulations,renovation and remodeling work that results in the removal,stripping,or altering
of asbestos containing materials requires an asbestos survey and removal prior to disturbing the asbestos.Please contact AQMD at(909)396-2000 for
further information.
Name / a✓ Title /LO IS, r / !4iL
PRINT
I certify that I have read this application and state that the above information is correct and that I am the owner or duly authorized agent of the owner.
I agree to comply with all City ordinances and State Laws relating to building construction. I hereby authorize representatives of the City of
Arcadia to enter upon the above-mentioned property for inspection purposes.
711
Signature 1( Date
NOTES
Building Inspections Date Insp. Plumbing Inspections I Date Insp. 2,tib$ �"D tit
100. Setbacks 210. Under fir/bldg.drain &
101. Rough grade 211. Copper underslab
102. Figs.&forms �� 212. Rough plumbing
103. Pre-slab 213. Rough gas
104. Floor joists 214. Shower pan
105. Steel 215. Water heater
106. Grout lift 216. Roof drains
107. Shear nailing Y 10 17. Building sewer
108. Diaph nailing 2-2-0 218. Water service
109. Roof nailing 3•i$•Liz 219. Final gas
•01
110. Framing -Ze /w� 220. Fixtures
111. 0cc./Area Sept.Wall 221. Final plumbing _ -26-Z
112. Sound walls 222. Sewer cap/demo.
113. T-bar.rid
114. Insulation-Fir. - Pool Inspections I Date I Insp.
115. Insulation-Wall -��2d OFP'> 240. Excavation/steel
116. Insulation-Ceil. 241. Rough plumbing
117. Drywall nailing .-/`Y ZD / 40 242. Light shell/bonding
118. Interior lath .�9 t 243. Underground conduit
119. Exterior lath --1 y- 244. P-trap
120. Finish grade 245. Gas line&test
121. Final building 8 246. Fence,gates&signs
122. Final demo/lot clear 247. Pool heater
248. Final electric
Electrical Inspections Date Insp. 249. Final.lumbin.
150. Power pole 250. Pool cover
151. Sales lot lighting 251. Pool final
152. Under.round conduit
153. Underslab conduit -- Reroof Inspections Date Insp.
154. UFER ground / 270. Pre-reroof insp.
155. Water ground 2 1. Roof framing
156. Rough electrical 272. Sheathing nailing
157. Fixtures 273. Final reroof
158. G.F.C.I.
159. E..t.bondin. -MEM Sign Inspections I Date I Insp.
160. Service panel rj"- 280. Setback/overhang
161. Final electric - 81. Footing
282. Conduit/wirin.
Mechanical Inspections Date Insp. 283. Disconnect --
180. Venting/flue -�284. Final sign --
181. Furnace/A.C.
182. Rouch HVAC ,j,G-ZO • Date Insp.
183. Fire dampers 290. Fire alarm
184. Furnace compartment 291. Underground supply
185. Combustion air 292. Fire sprinklers
186. Smoke detectors t).40 293. Monitor system
187. Metal F.P.rough 294. Hood dry chem.
188. Compressor setback 295. Final
189. Commercial hood
190. Duct shaft Mel Sewers&Offsite Insp. I Date I Insp.
191. Final mechanical Z , 300. Lateral(main to P/L)
, 301. SaddlePi --
Block Wall Inspections Date Insp. 302. Cess.••I filled
200. Footings 303. Sidewalk
201. Steel/rebar 304. Driveway
202. Grout lift 305. Curb replacement
203. Final wall 306. Trash bin
----:,--,,,-,‘,,' \ /,1 -', , :,11"',,) -___-_,'-- ,,\,‘ i if/ -11 .1P-- --N—rrl' cr__---T-27----m----- (----KsTh4,,t\ Ac--"<„---_ '\ //,--:-• itilt,H)------.-7,-. .,--1\: 447' ,''
.
•
i's,
/144=•
i
(..,,,,, ,, .4c',
Certificate of Occupancy ,,,,, _,,,,,,,,: .,,
City of Arcadia
',,..::',.''',..
Development Services Department—Building Division n
4 '
c r, ,:!: , \ .�
�j This certificate issued pursuant to the requirements of the
California Building Code certifying that at the time of issuance this structure was in ``
compliance with the various ordinances of the City regulating building construction or use. s'
T!l lire
Permit No. 18-1952 r
:1:.,,-:-::,..,-.,,"1,/:(::
Building Address: 2608 DURHAM CT ARCADIA, CA 91007 r
Permit Type: MF NEW Effective CBC: 2016 C.R.C.
�1Occupancy Code: R-3/UZone Code: Mu ,
( , ,
Final Date: 9-16-2020 Type of Construction: TYPE VB SPRINKLERED
) '
Owner: LENNAR HOMES OF CALIFORNIA
rI., / . .
1:-.L../: ,
' Kenne h Fields,B rtIR ing Offcia
`�' x;'
1 Post in Conspicuous Place :::/\."'''•\‘'/I\
�1
J
•
o •,. City of Arcadia, CA Permit NO. MEP-19-2564
Development Services Department Permit Type:MEP
240 West Huntington Drive,Post Office Box 60021
Arcadia,CA 91066-6021 Work Classification:MEP-Residential
(626)574-5416 Permit Status:Issued
A RCA DIA • • Issue Date: 12/27/2019 Expiration:
Addr NO. Dir Prefix Street Name Street Suffix Unit City,State,Zip
2608 DURHAM CT ARCADIA,
111.1141.10422v ‘14OUSINIM11111111111111111MIX.
Contacts
LENNAR HOMES OF CALIFORNIA* Owner
15131 ALTON PKWY 365,Irvine,CA 92618
(949)349-8215
Description:MEP FOR SF NEW. 125 AMP SERVICE.HVAC Valuation: $ 0.00 Tenant
SYSTEM PER APPROVED PLANS.HERS REQUIRED FOR FINAL.
Total Sq Feet: 0.00 Plan Check It Plan#
Fees Amount Payments Amount Paid
Bathtubs/or Combo $13.21 Total Fees $795.33
Bidet $26.42 Cash/Receipt#REC-03465-19 $795.33
Clothes Washer $13.21
Compressor 3-5 Ton(3 to 15 hp) $36.35 Amount Due: $0.00
Dishwasher $13.21 '
Electrical Permit Issuance Fee $47.01
Furnace or Burner<=100,000 BTU $19.86
Garbage Disposal Fee $13.21
Gas System(Outlets) $62.20
Hood Serviced by Mechanical Exhaust $14.96
Kitchen Sink $13.21 CALLS FOR INSPECTIONS
Laundry Trays $13.21 Request for inspection by telephone at 626-574-5450. Leave a message
Lavatories $79.26 requesting the address,timeframe and what inspection item is needed.
Mechanical Permit Issuance Fee $47.01
Motors,Generators<1 hp $8.07
New Residential Accessory Bldg (sq ft $30.38 This permit/plan review expires by time limitation and becomes null and
area) void if the work authorized by the permit is not commenced within 180 days
New Residential Elect.(sq ft area) $126.96 from the date of issuance or if the permit is not obtained within 180 days
Plumbing Permit Issuance Fee $47.01 from the date of plan submittal.This permit expires and becomes null and
Residential Services up to 400 amps $16.48 void if any work authorized by this permit is suspended or abandoned for 180
Sewer Connection on Property $33.01 consecutive days or if no progressive work has been verified by a City of
Shower $13.21 Arcadia building inspector for a period of 180 consecutive days.
Total: $795.33
0 Cr) if.
December 27, 2019
Issued By: Date
December 27,2019 Page 1 of 1
liFA;
`xIFOIN.ii.,I , h
4 111141111111
PERMIT/PLAN REVIEW APPLICATION •
E4lt6' Development Services Department,240 West Huntington Drive,Post Office Box 60021
/e
, Arcadia, CA 91066-6021,(626) 574-5416,Fax (626)447-9173
City of
Arcadia
LICENSED CONTRACTOR'S DECLARATION WORKERS'COMPENSATION DECLARATION
❑ I hereby affirm under penalty of perjury that I am licensed under provisions of I hereby affirm under penalty of perjury one of the following:
Chapter 9(commencing with Section 7000,of Division 3 of the Business and
Professions Code,and my license is in full force and effect. ❑ I have and will maintain a certificate of consent to self-insure for workers'
License Class License No. / /2 F,�Cpc.�ate compensation, as provided for by Section 3700 of the Labor Code, for the
Signature of Contractor (�/1'-' / ( (� performance of the work for which this permit is issued.
OWNER-BUILDER DECLARATION4
❑ I have and will maintain workers'compensation insurance,as required by Section
I hereby affirm under penalty of perjury that I am exempt from the Contractors 3700 of the Labor Code,for the performance of the work for which this permit
• nse Law for the following reason(Section 7031.5,Business and Professions is issued.My workers'compensation insurance carrier and policy numbers are:
Code.Any city or county which requires a permit to construct,alter,improve, Carrier
demolish,or repair any structure,prior to its issuance,also required the applicant /
for such permit to file a signed statement that he or she is licensed pursuant to the Policy Number ��_�// c----/
provisions of the Contractors License Law(Chapter 9(commencing with Section (This section need not be completed if till permit is for one hundred dollars or less)
7000)of Division 3 of the Business and Professions Code)or that he or she is
exempt there from and the basis for the alleged exemption. Any violation of 0 I certify that in the performance of the work for which this permit is issued,I shall
Section 7031.5 by any applicant for a permit subjects the applicant to a civil not employ any person in any manner so as to become subject to the workers'
penalty of not more than five hundred dollars($500)): compensation Laws of California,and agree that if I should become subject to the
workers'comp sation rovisions of Section 3700 of the Labor Code,I shall
❑I, as owner of the property, or my employees with wages as their sole forthwith corn with ose provisions
compensation,will do the work,and the structure is not intended or offered for
sale(Section 7044,Business and Professions Code:The Contractors License Date /!� 7 /45 Signature
Law does not apply to an owner of property who builds or improves thereon,
or who does such work himself or herself or through his or her own
employees,provided that such improvements are not intended or offered for WARNING: Failure to secure Workers'Compensation coverage is unlawful,
sale.If,however,the building or improvement is sold within one(1)year of and shall subject an employer to criminal penalties and civil fines up to one
completion,the owner-builder will have the burden of proving that he or she hundred thousand dollars($100,000),in addition to the cost of compensation,
did not build or improve for the purpose of sale). damages as provided for in Section 3706 of the Labor Code, interest, and
attorney's fees.
❑I, as owner of the property, am exclusively contracting with licensed
contractors to construct the project(Section 7044,Business and Professions
Code:The Contractors License Law does not apply to an owner of property CONSTRUCTION LENDING AGENCY
who builds or improves thereon,and who contracts for such projects with a I hereby affirm under penalty of perjury that there is a construction lending agency
contractor(s)licensed pursuant to the Contractors License Law). for the performance of the work for which this permit is issued (Section 3097,
Civil Code).
❑ I am exempt under Section 7044,Business and Professions Code,for this reason:
Lender's Name
t?/
Date /1 Signature7 '/ ' Lender's Address
IMPORTANT: APPLICATION IS HEREBY MADE TO THE BUILDING OFFICIAL FOR A PERMIT SUBJECT TO THE CONDITIONS AND
RESTRICTIONS SET FORTH ON THIS APPLICATION AND THE FOLLOWING:
1. The City's approved plans and permit inspection card must remain on the job site for use by City inspection personnel.
2. Final inspection of the work authorized by this permit is required.A Certificate of Occupancy must be obtained prior to use and occupancy of new buildings
and structures.
3. Per South Coast Air Quality Management District(AQMD)regulations,renovation and remodeling work that results in the removal,stripping,or altering
of asbestos containing materials requires an asbestos survey and removal prior to disturbing the asbestos.Please contact AQMD at(909)396-2000 for
further information.
Name/ Titlee '416>u>t
P NAME
I certify that I have read this application and state that the above information is correct and that I am the owner or duly authorized agent of the owner.
I agree to comply with all City ordinances and State Laws relating to building construction. I hereby authorize representatives of the City of
Arcadia to enter upon the above-mentioned property for inspection purposes.
// C.1
l1/r
Signature �/ /�— Date /� /r)
( •PtiOfl
done
CONSULTING ENGINEERS
PAGE 1 OF 1
STRUCTURAL OBSERVATION REPORT
CITY of ARCADIA
THIS REPORT INCLUDES ALL CONSTRUCTION WORK THROUGH THE: March 30, 2020
PROJECT "Essex"-SFD OPTION ONE J.N. 0918-2286
LOCATION , Arcadia,California BLDG.PERMIT NUMBER Mnew-18-1952
OWNER • Lennar Homes LOCATION/DIVISION Coastal
ARCHITECT , Angeleno ARCHITECT J.N. 1704
STRUCT.OBS.OF RECORD : Ilia Sarad,P.E.,S.E.,S.E.C.B. LIC.OR REGISTRATION No. S-3855
STRUCTURAL OBSERVER • Erik Torres,E.I.T. LIC.OR REGISTRATION No.
OBSERVED STRUCTURAL ELEMENTS&THEIR CONNECTIONS: LOT(S)&PHASE OBSERVED:
Interior and Exterior General Framing;i.e.,roof trusses,roof sheathing, Phase:1B. Tract:77121
shear elements,holdowns,floor sheathing,floor trusses,beams,headers,and HS#6,Plan IA
general hardware. 2608 Durham Court
Arcadia,California 91007
OBSERVED DEFICIENCIES: (ATTACH ADDITIONAL PAGES IF NECESSARY) Initial/Completion Date
The deficiencies noted during the observation visit have been corrected and/or installed
by a collaborated effort of the foreman and project superintendent. E.T. 03/30/20
Construction Stage: Double Sided Plywood Cl g Guard
N/A HVAC ❑Electrical LI Plumbing ❑Shear Walls U Lid(s) ❑ Deck Option ❑Rails
Note:When box is checked,it indicates that construction stage is in progress,and it has not yet been completed at the time of observation was conducted
STRUCTURAL SYSTEM WAS VISUALLY OBSERVED TO BE IN GENERAL CONFORMANCE WITH THE APPROVED PLANS
❑ STRUCTURAL DEFICIENCIES ARE OF A MINOR NATURE&MAY BE REVIEWED BY CITY BLDG INSPECTOR FOR COMPLIANCE
I DECLARE THAT THE FOLLOWING STATEMENTS ARE TRUE TO THE BEST OF MY KNOWLEDGE AND BELIEF
1. I AM THE REGISTERED ENGINEER WHO HAS RESPONSIBLE CHARGE FOR THE
STRUCTURAL OBSERVATION.
r
ESS/2. 1,OR ANOTHER QUALIFIED-CHARGE OBSERVER WHO I HAVE DESIGNATEDkq�ABOVE AND IS UNDER MY RESPONSIBLE CHARGE,HAS PERFORMED THEti/f nycREQUIRED SITE VISITS AT EACH SIGNIFICANT CONSTRUCTION STAGE TO
VERIFY IF THE STRUCTURE IS IN GENERAL CONFORMANCE WITH THEAPPROVED PLANS AND SPECIFICATIONS. 553. ALL DEFICIENCIES,WHICH I DOCUMENTED,HAVE BEEN CORRECTED UNLESS
OTHERWISE INDICATED ABOVE. 0224. ALL OBSERVED DEFICIENCIES SHALL BE CORRECTED AND APPROVED BY THE
OBSERVER PRIOR TO FINAL ACCEPTANCE OF THE STRUCTURAL SYSTEMS BYRP ,THE BUILDING DEPARTMENT. O
5. THIS REPORT IS PROVIDED TO THE OWNER AS A PART OF THE OWNERS
OVERALL CONSTRUCTION QUALITY CONTROL PROGRAM. March 30,2020
6. OPTION ONE HAS PROVIDED STRUCTURAL OBSERVATION IN ACCORDANCE
WITH THE SEAOC RECOM, ENDED GUIDE INES FOR THE PRACTICE OF STAMP OF ENGINEER-OF-RECORD
STRUCTURAL ENGINE •.', I C,1 O'
SIGNED BY: Ais . IF March March 30,2020
Ilia S- a P.E., . .C. .
STRUCTURAL OBSERVATI S DOE NOT WAIVE THE REQUIREMENTS FOR INSPECTIONS BY CITY BUILDING
INSPECTORS. ALL WORK MUST•OMP Y WITH THE APPROVED PLANS AND APPLICABLE STATE&LOCAL CODES.
2286SOR_frmg_H 56_P1A
Option One Tel 714.556.1916
Consulting Engineers 2755 Bristol Street, Suite 100,Costa Mesa,Ca.92626 Fax 714.556.1952
44_
ption
ne
PAGE 1 OF 1
STRUCTURAL OBSERVATION REPORT
LENNAR HOMES, CA
THIS REPORT INCLUDES ALL CONSTRUCTION WORK THROUGH THE: February 6,2020
PROJECT "Essex"-SF!) OPTION ONE J.N. 0918-2286
LOCATION Arcadia,California BLDG.PERMIT NUMBER Mnew-18-1952
OWNER Lennar Homes LOCATION/DIVISION Coastal
ARCHITECT Angeleno ARCHITECT J.N. 1704
STRUCT.OBS.OF RECORD . Ilia Sarad,P.E..S.E.,S.E.C.B. LIC.OR REGISTRATION No. S-3855
STRUCTURAL OBSERVER Erik Torres LIC.OR REGISTRATION No. .
OBSERVED STRUCTURAL ELEMENTS&THEIR CONNECTIONS: LOT(S)&PHASE OBSERVED:
Conventional Foundation System;i.e.,anchor bolts,holdown bolts&straps, Phase: 113, Tract: 77121
post bases.Strong-Wall/Hardy Framc anchor bolts.slab size/reinforcement and HS#6,Plan IA
footing&pad size/reinforcement(NOTE:monolithic pour system). 2608 Durham Court
Arcadia,California 91007
OBSERVED DEFICIENCIES: (ATTACH ADDITIONAL PAGES IF NECESSARY) Initial/Completion Date
The deficiencies noted during the observation visit have been corrected and/or installed
by a collaborated effort of the foreman and project superintendent. E.T. 02/06/20
Construction Stage: Double Sided Plywood CI'g Guard
N/A ❑HVAC ❑Electrical ❑Plumbing ❑Shear Wally Lid(y) ❑ Deck Option ❑ Rails
Note:When box is checked,it indicates that construction stage is in progress,and it has not yet been completed at the time of observation was conducted
X❑ STRUCTURAL SYSTEM WAS VISUALLY OBSERVED TO BE IN GENERAL CONFORMANCE WITH THE APPROVED PLANS
❑ STRUCTURAL DEFICIENCIES ARE OF A MINOR NATURE&MAY BE REVIEWED BY CITY BLDG INSPECTOR FOR COMPLIANCE
I DECLARE THAT THE FOLLOWING STATEMENTS ARE TRUE TO THE BEST OF MY KNOWLEDGE AND BELIEF
I. I AM THE REGISTERED ENGINEER WHO HAS RESPONSIBLE CHARGE FOR THE
STRUCTURAL OBSERVATION. ROFES$/��
2. I,OR ANOTHER QUALIFIED-CHARGE OBSERVER WHO I HAVE DESIGNATED P
ABOVE AND IS UNDER MY RESPONSIBLE CHARGE,HAS PERFORMED THE ����\�' 8•
5,4„? yc
REQUIRED SITE VISITS AT EACH SIGNIFICANT CONSTRUCTION STAGE TO
VERIFY IF THE STRUCTURE IS[N GENERAL CONFORMANCE WITH THE
APPROVED PLANS AND SPECIFICATIONS. ° NO. S 3855
3. ALL DEFICIENCIES,WHICH I DOCUMENTED,HAVE BEEN CORRECTED UNLESS
OTHERWISE INDICATED ABOVE. s s p. 3/31/2020 *
4. ALL OBSERVED DEFICIENCIES SHALL BE CORRECTED AND APPROVED BY THE
OBSERVER PRIOR TO FINAL ACCEPTANCE OF THE STRUCTURAL SYSTEMS BY 'qlR0CT VRP �\
THE BUILDING DEPARTMENT. or OAL�FO�
5. THIS REPORT IS PROVIDED TO THE OWNER AS A PART OF THE OWNERS
OVERALL CONSTRUCTION QUALITY CONTROL PROGRAM. February 6,2020
6. OPTION ONE HAS PROVIDED STRUCTURAL OBSERVATION IN ACCORDANCE
WITH THE SEAOC RECO MENDED GUIDELINES FOR THE PRACTICE OF STAMP OF ENGINEER-OF-RECORD
STRUCTURAL ENGINEE•IG C IFO/IA
SIGNED BY: AIWO I February 6,2020
Ilia Sarad, ., S ., S.E.I.5.
STRUCTURAL OBSERV TION DI S NOT WAIVE THE REQUIREMENTS FOR INSPECTIONS BY CITY BUILDING
INSPECTORS. ALL WORK . T CO. PLY WITH THE APPROVED PLANS AND APPLICABLE STATE&LOCAL CODES.
228650R_Foundation_H56_P1A.xls
Option One Tel 714.556.1916
Consulting Engineers 2755 Bristol Street,Suite 100,Costa Mesa,Ca.92626 Fax 714.556.1952
City of Arcadia, CA Permit NO.1111111 SOLR-20-0459
Development Services Department Permit Type:Solar
240 West Huntington Drive,Post Office Box 60021
Arcadia,CA 91066-6021 Work Classification:Solar-Residential
(626)574-5416 Permit Status:Issued
ARCADIA Issue Date:04/15/2020 Expiration: 10/12/2020
Addr NO. Dir Prefix Street Name Street Suffix Unit City,State,Zip Parcel Number
2608 DURHAM CT ARCADIA,CA 91006 5788020031
1, ..xterawnevamme NI. •
Contacts
LENNAR HOMES OF CALIFORNIA* Owner
15131 ALTON PKWY 365,Irvine,CA 92618
(949)349-8215
`
Description:ROOF MOUNTED SOLAR SYSTEM 8 Valuation: $ 0.00 Tenant
MODULES/MICROINVERTERS.SYSTEM SIZE 2.56 KW
Total Sq Feet: 0.00 Plan Check#20-453 Plan#
Fees Amount Payments Amount Paid
Building Plan Check Fee Residential $50.00 Total Fees $308.24
Electrical Permit Issuance Fee $47.01 Cash/Receipt#REC-04271-20 $308.24
Fire Plan Check Fee Residential $50.00
Amount Due: $0.00
Inverters $77.78
Panels $82.45
Solid Waste Management Fee 2 $1.00
Total: $308.24
rCIEE
......_
g-2 Z—Zd �lTYli!! �Gc ITJ,_#G L /r.
CALLS FOR INSPECTIONS
�-' Request for inspection by telephone at 626-574-5450. Leave a message
$-/Z- _ / ii'4 - requesting the address,timeframe and what inspection item is needed.
This permit/plan review expires by time limitation and becomes null and
void if the work authorized by the permit is not commenced within 180 days
from the date of issuance or if the permit is not obtained within 180 days
from the date of plan submittal.This permit expires and becomes null and
void if any work authorized by this permit is suspended or abandoned for 180
consecutive days or if no progressive work has been verified by a City of
Arcadia building inspector for a period of 180 consecutive days.
April 15, 2020
Issued By: Date
April 15,2020 Page 1 of 1
AR
00,lFORIN
4 1 PERMIT/PLAN REVIEW APPLICATION '
E#I*' Development Services Department,240 West Huntington Drive,Post Office Box 60021
Arcadia, CA 91066-6021, (626) 574-5416,Fax(626) 447-9173
City of
Arcadia
LICENSED CONTRACTOR'S DECLARATION WORKERS'COMPENSATION DECLARATION
❑ I hereby affirm under penalty of perjury that I am licensed under provisions of I hereby affirm under penalty of perjury one of the following:
Chapter 9(commencing with Section 7000,of Division 3 of the Business and
Professions Code,and my license is in full force and effect. ❑ I have and will maintain a certificate of consent to self-insure for workers'
License Class License No. Exp. Date compensation, as provided for by Section 3700 of the Labor Code, for the
performance of the work for which this permit is issued.
Signature of Contractor
OWNER-BUILDER DECLARATION 0 I have and will maintain workers'compensation insurance,as required by Section
❑ I hereby affirm under penalty of perjury that I am exempt from the Contractors 3700 of the Labor Code,for the performance of the work for which this permit
License Law for the following reason(Section 7031.5,Business and Professions is issued.My workers'compensation insurance carrier and policy numbers are:
Code.Any city or county which requires a permit to construct,alter,improve, Carrier
demolish,or repair any structure,prior to its issuance,also required the applicant
for such permit to file a signed statement that he or she is licensed pursuant to the Policy Number
provisions of the Contractors License Law(Chapter 9(commencing with Section (This section need not be completed if the permit is for one hundred dollars or less)
7000)of Division 3 of the Business and Professions Code)or that he or she is
exempt there from and the basis for the alleged exemption. Any violation of _nI certify that in the performance of the work for which this permit is issued,I shall
Section 7031.5 by any applicant for a permit subjects the applicant to a civil not employ any person in any manner so as to become subject to the workers'
penalty of not more than five hundred dollars($500)): compensation Laws of California,and agree that if I should become subject to the
workers'compensation provisions of Section 3700 of the Labor Code,I shall
❑I, as owner of the property, or my employees with wages as their sole forthwith comply with those provisions.
compensation,will do the work,and the structure is not intended or offered for
sale(Section 7044,Business and Professions Code:The Contractors License Date Signature
Law does not apply to an owner of property who builds or improves thereon,
or who does such work himself or herself or through his or her own
employees,provided that such improvements are not intended or offered for WARNING: Failure to secure Workers'Compensation coverage is unlawful,
sale.If,however,the building or improvement is sold within one(1)year of and shall subject an employer to criminal penalties and civil fines up to one
completion,the owner-builder will have the burden of proving that he or she hundred thousand dollars($100,000),in addition to the cost of compensation,
did not build or improve for the purpose of sale). damages as provided for in Section 3706 of the Labor Code, interest, and
attorney's fees.
❑I, as owner of the property, am exclusively contracting with licensed
contractors to construct the project(Section 7044,Business and Professions
Code:The Contractors License Law does not apply to an owner of property CONSTRUCTION LENDING AGENCY
who builds or improves thereon,and who contracts for such projects with a I hereby affirm under penalty of perjury that there is a construction lending agency
contractor(s)licensed pursuant to the Contractors License Law). for the performance of the work for which this permit is issued (Section 3097,
Civil Code).
❑ I am exempt under Section 7044,Business and Professions Code,for this reason:
Lender's Name
Date Signature Lender's Address
IMPORTANT: APPLICATION IS HEREBY MADE TO THE BUILDING OFFICIAL FOR A PERMIT SUBJECT TO THE CONDITIONS AND
RESTRICTIONS SET FORTH ON THIS APPLICATION AND THE FOLLOWING:
1. The City's approved plans and permit inspection card must remain on the job site for use by City inspection personnel.
2. Final inspection of the work authorized by this permit is required.A Certificate of Occupancy must be obtained prior to use and occupancy of new buildings
and structures.
3. Per South Coast Air Quality Management District(AQMD)regulations,renovation and remodeling work that results in the removal,stripping,or altering
of asbestos containing materials requires an asbestos survey and removal prior to disturbing the asbestos.Please contact AQMD at(909)396-2000 for
further information.
Name Title
PRINT NAME
I certify that I have read this application and state that the above information is correct and that I am the owner or duly authorized agent of the owner.
I agree to comply with all City ordinances and State Laws relating to building construction. I hereby authorize representatives of the City of
Arcadia to enter upon the above-mentioned property for inspection purposes.
Signature Date
• PERMIT/PLAN REVIEW APPLICATION
Development Services Department, 240 West Huntington Drive, Post Office Box 60021
j/ Arcadia,CA 91066-6021, (626) 574-5416, Fax (626)447-9173
ONLINE PERMIT/PLAN REVIEW APPLICATION
till 01
ARCADIA Job Site Address: 2&O ,Qui Qo Cf
LICENSED CONTRACTOR'S DECLARATION WORKERS'COMPENSATION DECLARATION
MI hereby affirm under penalty of perjury that I am licensed under provisions of I hereby affirm under penalty of perjury one of the following:
Chapter 9(commencing with Section 7000,of Division 3 of the Business and
Professions Code,and my license is in full force and effect. ❑ I have and will maintain a certificate of consent to self-insure for workers'
License Class Li . Axp Date compensation, as provided for by Section 3700 of the Labor Code, for the
Signature of Contractor performance of the work for which this permit is issued
OWNER-BUILDER DECLARATIONI have and will maintain workers'compensation insurance,as required by Section
ElI hereby affirm under penalty of perjury that 1 am exempt from the Contractors 3700 of the Labor Code,for the performance of the work for which this permit
License Law for the following reason(Section 7031.5.Business and Professions is issued.My workers'compensation insurance carrier and policy numbers are
Code.Any city or county which requires a permit to construct,alter,improve. Carrier
demolish,or repair any structure.prior to its issuance.also required the applicant f 1
for such permit to file a signed statement that he a she is licensed pursuant to the Policy Number
provisions of the Contractors License Law(Chapter 9(commencing with Section (This section need not be completed if the permit is for one hundred dollars or Ices)
7000)of Division 3 of the Business and Professions Code)or that he or she is
exempt there from and the basis for the alleged exemption Any violation of ElI certify that in the performance of the work for which this permit is issued.I shall
Section 7031.5 by any applicant fora permit subjects the applicant to a civil not employ any person in any manner so as to become subject to the workers'
penalty of not more than five hundred dollars(5500)): compensation Laws of California.and agree that if I should become subject to the
workers'compensation provisions of Section 3700 of the Labor Code.I shall
❑I, as owner of the property, or my employees with wages as their sole forthwith comply with those provisions
compensation,will do the work,and the structure is not intended or offered for
sale(Section 7044, Business and Professions Code:The Contractors License Date Signature
Law does not apply to an owner of property who builds or improves thereon,
or who does such work himself or herself or through his or her own
employees, provided that such improvements are not intended or offered for WARNING. Failure to secure Workers'Compensation coverage is unlawful.
sale.If,however,the building or improvement is sold within one(I)year of and shall subject an employer to criminal penalties and civil fines up to one
completion,the owner-builder will have the burden of proving that he or she hundred thousand dollars($100,000),in addition to the cost of compensatice,
did not build or improve for the purpose of sale). damages as provided for in Section 3706 of the Labor Code. interest, and
attorney's fees.
❑I, as owner of the property, am exclusively contracting with licensed
contractors to construct the project (Section 7044.Business and Professions
Code:The Contractors License Law does not apply to an owner of property CONSTRUCTION LENDING AGENCY
who builds or improves thereon,and who contracts fix such projects with a I hereby affirm under penalty of perjury that there is a construction lending agency
contractors)licensed pursuant to the Contractors License Law). for the performance of the work for which this permit is issued (Section 3097.
Civil Code).
❑ I am exempt under Section 7044,Business and Professions Code,for this reason.
Lender's Name
Date Signature Lender's Address_
1\11'OKTt\T: •11'l'LI('\IION Is 11E141 UN. \1. 1)1. 10 lilt. III II DING Ititll'111 I•Illt \ i't.K\ill 11Iilll'I IU Iilf 1•(j\I)IIIU\\ \\II
KESTKI(111)NS SEA FOR Ili U\ I III~.\I'I'I I( \I IU\ \1U 1111,I ill I U111\1,:
I. The City's approved plans and permit inspection card must remain on the job site for use by City inspection personnel.
2. Final inspection of the work authorized by this permit is required A Certificate of Occupancy must be obtained prior to use and occupancy of new buildings
and structures
3 Per South Coast Air Quality Management Dismct(AQMD)regulations,renovation and remodeling work that results in the removal,stripping,or altering
of asbestos containing materials requires an asbestos survey and removal prior to disturbing the asbestos Please contact AQMD at(909)396-2000 for
further information.
Name Title _
PRINT NAME
1 certify that I have read this application and state that the above information Is correct and that I am the owner or duly authorized agent of the owner.
I agree to comply with all City ordinances and State Laws relating to building construction. I hereby authorize representatives of the City of
Arcadia to enter upon the above-mentioned property for inspection purposes.
—.
Signature � � Date —/ /4 7,
4* SCOPE OF WORK LEGEND AND ABBREVIATIONS TABLE OF CONTENTS
BUYER ACKNOWLEDGES THAT THE SOLAR PAGE DESCRIPTION
MODULES TO BE INSTALLED PITCH TRUE AZIM MOD COUNT SOLARMODULEs #
' SERVICE ENTRANCE RAIL
THE ROOF OF THE HOME WILL BE
SUBSTANTIALLY IN THE ARRAY 1 21° 180° 8 MP MAIN PANEL PV-G SITE PLAN
LOCATIONS INDICATED BY THE ILLUSTRATION.
SP SUB-PANEL 1 PV-A LAYOUT
BUYER: L STANDOFFS&
PLAN 1 ELEVATION A LC PV LOAD CENTER FOOTINGS PV-E I ELECTRICAL
DATE CHIMNEY
ORIENTATION 2 LOT#6 T,eft DEDICATED PV METER
Q ATTIC VENT PV-E II SIGNAGE
INVERTER(S)WITH • SYSTEM SIZE:2.560 kW
INV INTEGRATED DCFLUSH ATTIC VENT • MODULES:(8)LG320NIK-V5
DISCONNECT AND AFCI a PVC PIPE VENT
AC AC DISCONNECT(S) (320W)
SITE PLAN -SCALE= 1/64" -1'-0" 0 METAL PIPE VENT • INVERTER(S):(8)ENPHASE
/` DC DC DISCONNECT(S) t0 T-VENT IQ 7+
,Nr SATELLITE • ROOF TYPE:TILE W/COMP
ICB SI COMBINER BOX Q DISH
_ SHINGLE AT ARRAY
FIRE SETBACKS
+�F
BATTERY
HARDSCAPE
IT/
AT AUTOTRANSFORMER
IIE L ftp_., -) / -PL- PROPERTY LINE
ilu I -`k' �- - J - BP PANEL
UP LOADS Ir-] SHOWN AS DASHED
EQUIPMENT r -1 INTERIOR
, . -
•
...
-
SUNSTREET
17312A SCALE.NTS
8EIGHTY
A AMPERE
\e/ 13 14 15 16 AC
AFCI ALTERNATING CURRENT
J ARC FAULT CIRCUIT INTERRUPTER
��7 / AZIM AZIMUTH
n- - i n Q COMP(E) COMPOSITION PHONE.
DC DIRECT CURRENT FAX
' EXISTING
LENNAR:DIVISION ADDRESS
EXT EXTERIOR CUSTOMER RESIDENCE
rir �\LL�6 T FRMFRAMING2608 DURHAM COURT
INT INTERIOR
LBW LOAD BEARING WALL ARCADIA,CA 91007
Ell
_ '•4F MAG MAGNETIC
W j� \ I Jll- ---rp-- MSP NEW SERVICE PANEL TEL MKa
�zjir M
s j NTS NOT TO SCALE PROJECT NUMBER:
✓ FFA 366.0 OC ON CENTER PROJ0109200
•'07ET P 3 PRE-FAB PRE-FABRICATED
v DESIGNER:NOE FLORES
illi PVF POUNDS PER SQUARE FOOT
41 40 39 38 37 PH#303-723-7261
PV PHOTOVOLTAIC
TRANSFII 1 TYP TYPICAL DRAFTER:DRAFTER:NOE FLORES
tV VOLTS
_ 17"ti U W WATTS
*if ki-it�W 4+4 6 9 / IO 11T
12� SHEECOVER SHEET
REV NAMEDATE COMMENTS
�! REV A12/4/2019
\6111:t1-1
gir.u. .-r. /444 ` 6°-n1 I /ern' A PAGE PV-G
SYSTEM LAYOUT-SCALE=3/32"-1'-0" • SYSTEM SIZE:2.560 kW
• MODULES:(8)LG320NIK-V5
,00"� (N) RAIL • INVERTER(S):(8)ENPHASE
[ `44.IF
3'1 5'-5"-t- 2'-10" 107+
(N) FOOT • ROOF TYPE:TILE W/COMP
0. K o a M1 a •a SHINGLE AT ARRAY
_ a
[ 7
FIRE SETBACKS ▪ """ - St
FIRE SETBACKS .f.. 0 1 111 NI
(3,TYP) .f.f .. -
ffff
ARA
.
MB
-
• NO
ffff •• `•
• f i-
[ 1
— 4'TYP
XXXX
O 111 I
.• .f - 27'-7"
• •• •• , 26'-10"
1.00 11,0 SO - FLASHING
•r ff
IIII •• •• - - - SUNSTREET
ZINO 110 ON
:... II1 11 T -
"" 01 .. 8EIGHTY
rf
K 1 ® s
q LENNAR:DIVISION ADDRESS
PHONE
FAX.
INNN_
••_-•`(••: ...f". CUSTOMER RESIDENCE.
i2608 DURHAM COURT
ARCADIA,CA 91007
TEL. TMK#
1_ R a. a o PROJECT NUMBER:
PROJ0109200
N
DESIGNER:NOE FLORES
PH#:303-723-7261
CI
AC OCB^ PM DRAFTER:NOE FLORES
(N) PROPERTY LINE
--- (N)ARRAY AR-01
- (N) DRIVEWAY LQ'l '1=1SHEET
LAYOUT
(N) RESIDENCE -
REV:A 12/4/2019
S PAGE PV-A
d120/240 VAC
SINGLE PHASE
SERVICE
(` METER#:
UTILITY O
GRID I
NEW 200 A
MAIN
BREAKER (N)60A ENPHASE •MAX 13 MICRO-INVERTERS PER BRANCH CIRCUIT
AC COMBINER BOX •MULTIPLE BRANCH CIRCUITS IN PARALLEL
20A PV BREAKER WITH •ENPHASE MULTI-PIN CONNECTORS-1ST AC CONNECTOR AT
NEW 10A ENVOY BREAKER EACH BRANCH CIRCUIT ISA SUITABLE DISCONNECTING MEANS.
I 200A (N)LOCKABLE •DO NOT DISCONNECT/CONNECT UNDER LOAD
MAIN BLADE TYPE
FACILITY PANEL/:3 AC DISCONNECT 3 2 OR N Ex
r' -__.--
LOADS II X-• OR EQUIVALENT /
1 I { (1)BRANCH OF
.,�"'[ (8)MICRO-INVERTERS
44,s [•i[I.1 NM •
20A PV iSQUARED _ A 1- • )
BREAKER AT DU222RB
OPPOSITE END 3R,60A,2P
OF BUSBAR 120/240VAC
SYSTEM SIZE OPTION CONDUIT SCHEDULE
MODULE POWER SYSTEM SIZE(kW # CONDUCTOR WIRE TYPE TYPE LOCATION TRADE
OPTION MODULE QTY. (WATTS DC) DC @STC) 1 1#12 ENPHASE 0 CABLE, CU UL3003,DG ARRAY SOLAR
1460,FREE AIR CABLE
A 8 320 2.56 2 3410,1410 EGC CU NM-B(ROMEX) INTERIOR SOLAR
3 3410,1410 EGC CU NM-B(ROMEX) INTERIOR SOLAR
CONDUCTOR SIZING CALCULATIONS
1)CONDITION OF USE(COU): (AMPACITY'TEMP.DERATEFILL DERATE)vs.REQ'D(INAx) INTERCONNECTION CALCULATIONS
2)TERMINALS(TERM). AMPACITY AT TERMINALS.vs.REQ'D,(IMAX•1.25)
ITEM UNIT PANEL
KEY SIZE CU/AL INSULATION CALC. AMPACITY W/O TEMP. FILL RESULT REO'D OCD
TYPE DEBATES DERATE DERATE (A) (A) USED(A) PANEL MANUFACTURER CUTLER HAMMER n= SUNSTREET
1 #12 CU THWN-2 COU 30 0.76 1.00 22.80 9.68
TERM 25 25.00 12.10 20.00 BUS RATING AMPS 200
8EIGHTY
2 #10 CU NM-B COU 40 0.91 1.00 36.40 9.68 MAIN DISCONNECT AMPS 200
TERM 35 35.00 12.00 20.00
3 #10 CU NM-B COU 40 1.00 1.00 36.00 10.00 ALLOWED PV PER NEC AMPS 40
TERM 35 35.00 12.00 20.00 PV OCPD USED AMPS 20 LENNAR.DIVISION ADDRESS
PHONE,
FAX.
MODULE SPECIFICATION AND CALCULATIONS INVERTER SPECIFICATIONS AND CALCULATIONS
ITEM NOTE/CALCULATION UNIT DETAIL ITEM NOTE/CALCULATION UNIT DETAIL CUSTOMER RESIDENCE:
LOCATION ARCADIA,CA INVERTER MAKE INVERTER SPEC ENPHASE 2608 DURHAM COURT
TEMP,AMBIENT RIGHT(Tmax) ASHRAE 2% UC 31 INVERTER MODEL INVERTER SPEC °C IQ7PLUS-72-2-US ARCADIA,CA 91007
TEMP,AMBIENT LOW(Turin) ASHRAE EXTREME MIN `'C -2
INVERTER MAX POWER(Wac MAX) INVERTER SPEC WATTS(AC) 295
TEMP,MODULE TEST(Rest) MODULE SPEC °C 25 TEL. TMK#
TEMP,DELTA LOW(Tdelta) Tmn-Ttest "C -27 INVERTER INPUT VOLTAGE(Voc MAX) INVERTER SPEC VOLTS(DC) 60
PROJECT NUMBER:
MODULE MANUFACTURER MODULE SPEC LG INVERTER OUTPUT VOLTAGE(Vac NOM) INVERTER SPEC VOLTS(AC) 240 PROJ0109200
MODULE PART NUMBER MODULE SPEC LG32ONIK-V5(320W) INVERTER OUTPUT FREQUENCY INVERTER SPEC HERTZ 60
MODULE POWER STC(P) MODULE SPEC WATTS(DC) 320DESIGNER:NOE FLORES
INVERTER OUTPUT CURRENT(lac) INVERTER SPEC AMPS(AC) 1.21
PH#:303-723-7261
MODULE OPERATING VOLTAGE(VMP) MODULE SPEC VOLTS(DC) 33.3
- INVERTER PHASE QUANTITY INVERTER SPEC PHASE 1
MODULE OPEN CIRCUIT VOLTAGE MODULE SPEC VOLTS(DC) 40.8 DRAFTER:NOE FLORES
(VOC) COMPLIACE INVERTER SPEC ULI741/IEEE1547
- MODULE COEF.VOLT/TEMP(Coes MODULE SPEC V/C° -0.27
INVERTER GROUNDING INVERTER SPEC ISOLATED
l
MODULE MAX VOLTAGE(Vmecmod) (VOC+(TD'COEF)) VOLTS(DC) 48.09 SHEET
_MODULE OPERATING CURRENT(IMP) MODULE SPEC AMPS(DC) 962 INVERTER QTY.MAX PER BRANCH MODULE QTYbc QTY 8 ELECTRICAL
MODULE SHORT CIRCUIT CURRENT MODULE SPEC AMPS(DC) 10.19 CIRCUIT
' (ISC) BRANCH CIRCUIT OUTPUT(Imaxbc) (IAC•MODULE QTYbc) AMPS(AC) 9.69 REV:A 12/4/2019
MODULE MAXIMUM CURRENT(IMAX) (ISC'1.25) AMPS(DC) 12.74
INVERTER QTY.TOTAL MODULE QTYI QTY 9 PAGE
MINIMUM AMPACITY REQ'D.PER NEX IMAX'1.25) AMPS(DC) 15.92 E-1
SERIES FUSE RATING,MAX MODULE SPEC AMPS(DC) 20 TOTAL SYSTEM OUTPUT(Imaxts) (IAC•MODULE QTYt) AMPS(AC) 9.68
AWARNING AWARNING
CA U T I O N ■
■ INVERTER OUTPUT CONNECTION DUAL POWER SUPPLY
POWER TO THIS BUILDING IS DO NOT RELOCATE THIS SOURCES: UTILITY GRID
ALSO SUPPLIED FROM THE OVERCURRENT DEVICE
J AND PV SOLAR ELECTRIC
FOLLOWING SOURCES WITH LABEL LOCATION: \ SYSTEM J
ADJACENT TO PV BREAKER(IF LABEL LOCATION:
DISCONNECTS AS SHOWN APPLICABLE). UTILITY SERVICE METER AND MAIN
PER CODE(S):CEC 2016:705.12(D)(2)(3)(b) SERVICE PANEL.
PER CODE(S):CEC 2016:705.12(D)(3)
, SOLADECK WIRE TRANSITION
BOX(UNDER ARRAY) AWARNING
W. 1 SOLAR PANELS ON ROOF AWARNING
pAiAlELECTRICAL SHOCK HAZARD
DO NOT TOUCH TERMINALS. ELECTRICAL SHOCK HAZARD
TERMINALS ON LINE AND LOAD IF GROUND FAULT IS INDICATED
SIDES MAY BE ENERGIZED IN ALL NORMALLY GROUNDED
dilliMilirar/gdrAr
� THE OPEN POSITION CONDUCTORS MAY BE
�� PV AC DISCONNECT LABEL LOCATION EXTERIOR INVERTER(S).AC DISCONNECT(S),AC COMBINER PANEL UNGROUNDED AND ENERGIZED
(IF APPLICABLE). /
AC COMBINER BOX PER CODES) CEC 2016: LABEL LOCATION:
690.17(E) INVERTER(S),ENPHASE ENVOY ENCLOSURE(IF
UTILITY METER&MAIN APPLICABLE).
•SERVICE PANEL PER CODE(S):CEC 2016.690,5(C)
PHOTOVOLTAIC AC DISCONNECT
SERVICE BY QUALIFIED 1 MAXIMUM AC OPERATING CURRENT: 9.69 AMPS
sus
PERSONNEL ONLY CONTACT: i NOMINAL OPERATING AC VOLTAGE: 240 VAC In SUNSTREET
SUNSTREET ENERGY GROUP
1-877-SLR-POWR LABEL LOCATION: 8EIGHTY
i AC DISCONNECT(S),PHOTOVOLTAIC SYSTEM POINT OF
INTERCONNECTION,
PHOTOVOLTAIC SYSTEM PER CODE(S):CEC 2016:690.54
LENNAR.DIVISION ADDRESS
WARNING: PHOTOVOLTAIC FAX EQUIPPED WITH AC DISCONNECT CUSTOMER RESIDENCE.
RAPID SHUTDOWN 2608 DURHAM COURT
LABEL LOCATION. ARCADIA,CA 91007
INTERIOR AND EXTERIOR DC CONDUIT EVERY 10 FT.AT EACH TURN,ABOVE AND
BELOW PENETRATIONS.ON EVERY JB/PULL BOX CONTAINING DC CIRCUITS.
LABEL LOCATION. PER CODE(S) CEC 2016:690.31(G)(3).690.31(G)(4(
UTILITY SERVICE ENTRANCE/METER,OR AS REQUIRED BY LOCAL AHJ. TEL TMK 6
PER CODE(S) CEC 2016 690.12 PROJECT NUMBER:
WARNING: PHOTOVOLTAIC PROJ0109200
NOTES AND SPECIFICATIONS.
•SIGNS AND LABELS SHALL MEET THE REQUIREMENTS OF THE CEC 2016 DESIGNER:NOE FLORES
AND NEC 2014 ARTICLE 110.21(B),UNLESS SPECIFIC INSTRUCTIONS ARE
REQUIRED BY SECTION 690,OR IF REQUESTED BY THE LOCAL AHJ. PH#:303-723-7261
•SIGNS AND LABELS SHALL ADEQUATELY WARN OF HAZARDS USING POWER S URC E
EFFECTIVE WORDS,COLORS AND SYMBOLS. DRAFTER:NOE FLORES
•LABELS SHALL BE PERMANENTLY AFFIXED TO THE EQUIPMENT OR WRING
METHOD AND SHALL NOT BE HAND WRITTEN,UNLESS PORTIONS OF LABEL LOCATION:
LABELS OR MARKINGS ARE VARIABLE,OR THAT COULD BE SUBJECT TO INTERIOR AND EXTERIOR DC CONDUIT EVERY 10 FT,AT EACH TURN,ABOVE AND
CHANGES,SHALL BE PERMITTED TO BE HAND WRITTEN AND SHALL BE BELOW PENETRATIONS,ON EVERY JB/PULL BOX CONTAINING DC CIRCUITS. SHEET
LEGIBLE. PER CODE(S):CEC 2016:690.31(G)(3),690.31(G)(4) SIGNAGE
•LABEL SHALL BE OF SUFFICIENT DURABILITY TO WITHSTAND THE
ENVIRONMENT INVOLVED.
•SIGNS AND LABELS SHALL COMPLY WITH ANSI Z535.4-2011,PRODUCT REV:A 12/4/2019
SAFETY SIGNS AND LABELS.UNLESS OTHERWISE SPECIFIED.
•DO NOT COVER EXISTING MANUFACTURER LABELS. PAGE E-2