Loading...
HomeMy WebLinkAboutMNEW-18-1961 .-- ' A \ A� - �' A 7.---• A —_ A --- r " 1 Certificate ofOccupancy ;� ...) City of Arcadia Development Services Department—Building Division i). 1 ,/ - This certificate issued pursuant to the requirement of the ,,=\\ California Building Code certifying that at the time of issuance this structure was in compliance with the various ordinances of the City regulating building construction or use. Permit No. 18-1961 , „,) / Building Address: 2617 DERBY CT ARCADIA, CA 91007 i� Permit Type: MF NEW Effective CBC: 2016 C.B.C. -1 I Occupancy Code: - R-3/U Zone Code: M� Final Date: 9-16-2020 Type i'. of Construction: TYPE VB SPRINKLERED II f i \ Owner: LENNAR HOMES OF CALIFORNIA 7 � Kenneth Field lding4/2 //1 II '/`\� Post in Conspicuous Place 1 O •ption A 40 n CONSULTING ENGINEERS PAGE 1 OF 1 STRUCTURAL OBSERVATION REPORT CITY of ARCADIA THIS REPORT INCLUDES ALL CONSTRUCTION WORK THROUGH THE: April 1, 2020 PROJECT : "Essex"-SFD OPTION ONE J.N. 0918-2286 LOCATION : Arcadia,California BLDG.PERMIT NUMBER Mnew-18-1961 OWNER : Lennar Homes LOCATION/DIVISION Coastal ARCHITECT Angeleno ARCHITECT J.N. 1704 STRUCT.OBS.OF RECORD Ilia Sarad,P.E.,S.E.,S.E.C.B. LIC.OR REGISTRATION No. S-3855 STRUCTURAL OBSERVER , Erik Torres,E.I.T. LIC.OR REGISTRATION No. OBSERVED STRUCTURAL ELEMENTS&THEIR CONNECTIONS: LOT(S)&PHASE OBSERVED: Interior and Exterior General Framing;i.e.,roof trusses,roof sheathing, Phase:1B. Tract: 77121 shear elements,holdowns,floor sheathing,floor trusses,beams,headers,and HS#9,Plan 2A general hardware. 2617 Derby Court Arcadia,California 91007 OBSERVED DEFICIENCIES: (ATTACH ADDITIONAL PAGES IFNECESSARY) Initial/Completion Date The deficiencies noted during the observation visit have been corrected and/or installed by a collaborated effort of the foreman and project superintendent. ET 04/01/20 Construction Stage: HVAC ❑Electrical Plumbing ❑Double Sided ❑ Plywood Crg Deck Option ❑Guard N/A Shear Walls Lid(s) Rails Note:When box is checked,it indicates that construction stage is in progress,and it has not yet been completed at the time of observation was conducted ❑X STRUCTURAL SYSTEM WAS VISUALLY OBSERVED TO BE IN GENERAL CONFORMANCE WITH THE APPROVED PLANS ❑ STRUCTURAL DEFICIENCIES ARE OF A MINOR NATURE&MAY BE REVIEWED BY CITY BLDG INSPECTOR FOR COMPLIANCE I DECLARE THAT THE FOLLOWING STATEMENTS ARE TRUE TO THE BEST OF MY KNOWLEDGE AND BELIEF 1. I AM THE REGISTERED ENGINEER WHO HAS RESPONSIBLE CHARGE FOR THE STRUCTURAL OBSERVATION. QROFESS/ 2. I,OR ANOTHER QUALIFIED-CHARGE OBSERVER WHO I HAVE DESIGNATED � ABOVE AND IS UNDER MY RESPONSIBLE CHARGE,HAS PERFORMED THE yS.4,P9E` REQUIRED SITE VISITS AT EACH SIGNIFICANT CONSTRUCTION STAGE TO VERIFY IF THE STRUCTURE IS IN GENERAL CONFORMANCE WITH THE rn APPROVED PLANS AND SPECIFICATIONS. taJ NO. S 3855 73 3. ALL DEFICIENCIES,WHICH I DOCUMENTED,HAVE BEEN CORRECTED UNLESS OTHERWISE INDICATED ABOVE. * Exp. 3/31/2022 4. ALL OBSERVED DEFICIENCIES SHALL BE CORRECTED AND APPROVED BY THE 411. OBSERVER PRIOR TO FINAL ACCEPTANCE OF THE STRUCTURAL SYSTEMS BY R UC T VKQ THE BUILDING DEPARTMENT. rF OF CAO 5. THIS REPORT IS PROVIDED TO THE OWNER AS A PART OF THE OWNERS OVERALL CONSTRUCTION QUALITY CONTROL PROGRAM. April 1,2020 6. OPTION ONE HAS PROVIDED STRUCTURAL OBSERVATION IN ACCORDANCE WITH THE SEAOC REC. 'MENDED GUIDELINES FOR THE PRACTICE OF STAMP OF ENGINEER-OF-RECORD STRUCTURAL ENGIN : i G ` C i ,, a',IA SIGNED BY: ow�a 1 :�, / April 1,2020 llia 'a -d, P. ,S.E. S.E.C.=. STRUCTURAL OBSERVATI I N DOE'NOT WAIVE THE REQUIREMENTS FOR INSPECTIONS BY CITY BUILDING INSPECTORS. ALL WORK MUST,OM: Y WITH THE APPROVED PLANS AND APPLICABLE STATE&LOCAL CODES. 228650R_frmg_H59_1'2A Option One Tel 714 556.1916 Consulting Engineers 2755 Bristol Street, Suite 100, Costa Mesa, Ca. 92626 Fax 714.556.1952 I •ption I •ne CONSULTING ENGINEERS PAGE 1 OF 1 STRUCTURAL OBSERVATION REPORT LENNAR HOMES, CA THIS REPORT INCLUDES ALL CONSTRUCTION WORK THROUGH THE: February 13, 2020 PROJECT , "Essex"-SFD OPTION ONE J.N. 0918-2286 LOCATION , Arcadia,California BLDG.PERMIT NUMBER Mnew-18-1961 OWNER Lennar Homes LOCATION/DIVISION Coastal ARCHITECT Angeleno ARCHITECT J.N. 1704 STRUCT.OBS.OF RECORD , Ilia Sarad,P.E.,S.E.,S.E.C.B. LIC.OR REGISTRATION No. S-3855 STRUCTURAL OBSERVER , Erik Torres LIC.OR REGISTRATION No. OBSERVED STRUCTURAL ELEMENTS&THEIR CONNECTIONS: LOT(S)&PHASE OBSERVED: Conventional Foundation System;i.e.,anchor bolts,holdown bolts&straps, Phase:IB, Tract: 77121 post bases,Strong-Wall/Hardy Frame anchor bolts,slab size/reinforcement and HS#9,Plan 2AR footing&pad size/reinforcement(NOTE:monolithic pour system). 2617 Derby Ct., • Arcadia,California 91007 OBSERVED DEFICIENCIES: (ATTACH ADDITIONAL PAOES1FNECESSARY) Initial/Completion Date The deficiencies noted during the observation visit have been corrected and/or installed by a collaborated effort of the foreman and project superintendent. E.T. 02/13/20 Construction Stage: Double Sided Plywood CI' Guard g 0 HVAC Electrical o Plumbing 0 g u Deck Option u N/A Shear Walls Lid(s) Rails Note:When box is checked,it indicates that construction stage is in progress,and it has not yet been completed at the time of observation was conducted aX STRUCTURAL SYSTEM WAS VISUALLY OBSERVED TO BE IN GENERAL CONFORMANCE WITH THE APPROVED PLANS Ei STRUCTURAL DEFICIENCIES ARE OF A MINOR NATURE&MAY BE REVIEWED BY CITY BLDG INSPECTOR FOR COMPLIANCE I DECLARE THAT THE FOLLOWING STATEMENTS ARE TRUE TO THE BEST OF MY KNOWLEDGE AND BELIEF 1. IAM THE REGISTERED ENGINEER WHO HAS RESPONSIBLE CHARGE FOR THE STRUCTURAL OBSERVATION. 00FESS 2. I,OR ANOTHER QUALIFIED-CHARGE OBSERVER WHO I HAVE DESIGNATED Q ABOVE AND IS UNDER MY RESPONSIBLE CHARGE,HAS PERFORMED THE ��� �\P B• S4 ( REQUIRED SITE VISITS AT EACH SIGNIFICANT CONSTRUCTION STAGE TO VERIFY IF THE STRUCTURE IS IN GENERAL CONFORMANCE WITH THE rn APPROVED PLANS AND SPECIFICATIONS. N0. S 3855 rn 3. ALL DEFICIENCIES,WHICH I DOCUMENTED,HAVE BEEN CORRECTED UNLESS OTHERWISE INDICATED ABOVE. * SExp. 3/31/2020 4. ALL OBSERVED DEFICIENCIES SHALL BE CORRECTED AND APPROVED BY THE OBSERVER PRIOR TO FINAL ACCEPTANCE OF THE STRUCTURAL SYSTEMS BY 9T RU C T k)% THE BUILDING DEPARTMENT. lF OF cALll 5. THIS REPORT IS PROVIDED TO THE OWNER AS A PART OF THE OWNERS OVERALL CONSTRUCTION QUALITY CONTROL PROGRAM. February 13,2020 6. OPTION ONE HAS PROVIDED STRUCTURAL OBSERVATION IN ACCORDANCE WITH THE SEAOC RECO'MENDED GUID LINES FOR THE PRACTICE OF STAMP OF ENGINEER-OF-RECORD STRUCTURAL ENGINE 7 G ' CC• IFO' IA. SIGNED BY: 411 _/►I-1.1 A a February 13,2020 Ilia Sarad, P.E.,S.E. .E.t,B. STRUCTURAL OBSERVAT IN DO S NOT WAIVE THE REQUIREMENTS FOR INSPECTIONS BY CITY BUILDING INSPECTORS. ALL WORK MUS' CO 'LY WITH THE APPROVED PLANS AND APPLICABLE STATE&LOCAL CODES. 2286508 Foundation H59 P2AR Option One Tel 714.556.1916 Consulting Engineers 2755 Bristol Street, Suite 100.Costa Mesa, Ca. 92626 Fax 714.556.1952