HomeMy WebLinkAboutELEC-19-0212 ``City of Arcadia, CA Permit NO. Elec-19-0212
Development Services Department Permit Type:Electrical
240 West Huntington Drive,Post Office Box 60021
Arcadia,CA 91066-6021 Work Classification:Elec-VCU-Residential
(626)574-5416 Permit Status:Issued
ARcAD IA Issue Date:02/04/2019 Expiration: 08/03/2019
Addr NO. Dir Prefix Street Name Street Suffix Unit City,State,Zip Parcel Number
�_...
639 W Longden AVE Arcadia, CA 5785015006
Contacts
CAROLINE SUN Owner Trout Electric Electrical Contractor
639 W LONGDEN AVE (C-10)
(626)586-0629 17843 Glen Hollow WAY,Riverside,CA 92504
(951)743-0702 933396
Description:240 OUTLET IN GARAGE Valuation: $ 0.00 Tenant
Total Sq Feet: 0.00 Plan Check# Plan#
Fees Amount Payments Amount Paid
Electrical Permit Issuance Fee $47.01 Total Fees $54.61
Electrical Vehicle Unit(240 Outlet) $6.60 Cash/Receipt#REC-00287-19 $54.61
Solid Waste Management Fee 2 $1.00
Amount Due: $0.00
Total: $54.61 -
CALLS FOR INSPECTIONS
Request for inspection by telephone at 626-574-5450. Leave a message
requesting the address,timeframe and what inspection item is needed.
This permit/plan review expires by time limitation and becomes null and
void if the work authorized by the permit is not commenced within 180 days
from the date of issuance or if the permit is not obtained within 180 days
from the date of plan submittal.This permit expires and becomes null and
void if any work authorized by this permit is suspended or abandoned for 180
consecutive days or if no progressive work has been verified by a City of
Arcadia building inspector for a period of 180 consecutive days.
EXPIRED
vV February 04, 2019
Issued By: Date
February 04,2019 Page 1 of 1
•c R
4 ! 1 PERMIT/PLAN REVIEW APPLICATION
0fia, ~ Development Services Department,240 West Huntington Drive,Post Office Box 60021
0.a,„of Arcadia, CA 91066-6021, (626) 574-5416,Fax(626)447-9173
City of
Arcadia
LICENSED CONTRACTOR'S DECLARATION WORKERS'COMPENSATION DECLARATION
0 I hereby affirm under penalty of perjury that I am licensed under provisions of I hereby affirm under penalty of perjury one of the following:
Chapter 9(commencing with Section 7000,of Division 3 of the Business and
Professions Code,and my license is in full force and effect. ❑ I have and will maintain a certificate of consent to self insure for workers'
License Class • nse Exp. Date_/'/30,/9 compensation, as provided for by Section 3700 of the Labor Code, for the
performance of the work for which this permit is issued.
Signature of Contracto t�
12Kave and will maintain workers'compensation insurance,as required by Section
OWNER-BUILDER DECLARATION
❑ I hereby affirm under penalty of perjury that I am exempt from the Contractors 3700 of the Labor Code,for the performance of the work for which this permit
License Law for the following reason(Section 7031.5,Business and ProfessionsIr u is issued.My workers'compensation insur a carrier and policy numbers are:
Code.Any city or county which requires a permit to construct,alter,improve, Carrier NO ctf al I/I S
demolish,or repair any structure,prior to its issuance,also required the applicant
Policy Number+"l'T�f jf 7 d OZ.3 7
for such permit to file a signed statement that he or she is licensed pursuant to the
provisions of the Contractors License Law(Chapter 9(commencing with Section (This section need not be completed if the permit is for one hundred dollars or less)
7000)of Division 3 of the Business and Professions Code)or that he or she is
0 I certify that in the performance of the work for which this permit is issued,I shall
exempt there from and the basis for the alleged exemption. Any violation of
Section 7031.5 by any applicant for a permit subjects the applicant to a civil not employ any person in any manner so as to become subject to the workers'
penalty of not more than five hundred dollars($500)): compensation Laws of California,and agree that if I should become subject to the
workers'compensation provisions of Section 3700 of the Labor Code,I shall
❑I, as owner of the property, or my employees with wages as their sole forthwith comply with those provisions.
compensation,will do the work,and the structure is not intended or offered for •
Date 2l'¢//`1 Signa
sale(Section 7044,Business and Professions Code:The Contractors License
Law does not apply to an owner of property who builds or improves thereon,
or who does such work himself or herself or through his or her own
employees,provided that such improvements are not intended or offered for WARNING: Failure to secure Workers'Compensation coverage is unlawful,
sale.If,however,the building or improvement is sold within one(1)year of and shall subject an employer to criminal penalties and civil fines up to one
completion,the owner-builder will have the burden of proving that he or she hundred thousand dollars($100,000),in addition to the cost of compensation,
did not build or improve for the purpose of sale). damages as provided for in Section 3706 of the Labor Code, interest, and
attorney's fees.
❑I, as owner of the property, am exclusively contracting with licensed
contractors to construct the project(Section 7044,Business and Professions
Code:The Contractors License Law does not apply to an owner of property CONSTRUCTION LENDING AGENCY
who builds or improves thereon,and who contracts for such projects with a I hereby affirm under penalty of perjury that there is a construction lending agency
contractor(s)licensed pursuant to the Contractors License Law). for the performance of the work for which this permit is issued (Section 3097,
Civil Code).
❑ I am exempt under Section 7044,Business and Professions Code,for this reason:
Lender's Name
Date Signature Lender's Address
IMPORTANT: APPLICATION IS HEREBY MADE TO THE BUILDING OFFICIAL FOR A PERMIT SUBJECT TO THE CONDITIONS AND
RESTRICTIONS SET FORTH ON THIS APPLICATION AND THE FOLLOWING:
1. The City's approved plans and permit inspection card must remain on the job site for use by City inspection personnel.
2. Final inspection of the work authorized by this permit is required.A Certificate of Occupancy must be obtained prior to use and occupancy of new buildings
and structures.
3. Per South Coast Air Quality Management District(AQMD)regulations,renovation and remodeling work that results in the removal,stripping,or altering
of asbestos containing materials requires an asbestos survey and removal prior to disturbing the asbestos. Please contact AQMD at(909)396-2000 for
further information. Oind
L/+ Jame ama i!7 r
Title /?
PRINT NAME
I certify that I have read this application and state that the above information is correct and that I am the owner or duly authorized agent of the owner.
I agree to comply with all City ordinances and State Laws relating to building construction. I hereby authorize representatives of the City of
rcadia to enter upon the above-mentioned property for inspection purposes.
ignature Date /i-A
LIC#933396 s
TAT
1131=1
Project Address 639 Longden
General Lighting Load Your home's square footage 5,368 16,104
Small appliance branch circuits(2 min) 1500 VA X 2 Circuits 3,000
Laundry Circuit 1500 VA X 1 Circuit(s) 1,500
APPLIANCES AND EQUIPMENT-Values are minimums,use actual values if known to be greater.
Enter N/A if not present at project site
Microwave 1300 1,300
Compactor 1000 -
Dishwasher 1200 1,200
Disposal 800 800
Proposed EVSE circuit 7200 11,520
Pool/Spa Pump 1 horsepower 1920 -
Pool/Spa Pump 1.5 horsepower 2400 -
Pool/Spa Pump 2 horsepower 2880 -
Oven 4000 6,000
Range 5100 -
Electric Water Heater 4500 -
F.A.U. 1500 3,000
50A circuit -
dryer -
Subtotal (A) 44,424
Subtotal(A) minus 10,000 VA 34,424 X 0.40= 13769.6
plus 10,000
Subtotal (B) 23769.6
Total A/C Load, use nameplate rating or A/C circuit breaker rating(C) 18000
D=(B)+(C) 41769.6
Total demand is D/240V= 174.04
Plan Checker Notes:
} E
sw
v
,., 1 r g
8wvs- A °v
t:',
x
; +
k
F ,
r
E
h
3
& ham' • 41
C
33
.. h a
•
z- ,•, ., �.« ..:. s,. r : ,
1
t
4
p #ticat#coiis
The maximum power rating for the Wall Connector is 20 kW or 80A at 250V AC single-phase
power.Your vehicle can charge from 200V to 277V single-phase power.
s:3e at!'dp1 i,7n
Voltage and Wiring 277V AC single-phase:Ll,neutral,and earth
208V or 240V AC single-phase:Ll,L2,and earth
Current Maximum output:80A,72A.64A,56A,48A,40A,36A,
32A,28A,24A,20A,16A,12A
Frequency 50 to 60 Hz
Cable Length 8.5'(2.6 m)and 24'(7.4 m)
Wall Connector Dimensions Height:15.0"(380 mm)
Width:6,3"(160 mm)
Depth:S 5"(140 mm)
Top Entry Bracket Dimensions Height:10.8"(275 mm)
Width:151"(130 mm)
Depth:2.0"(50 mm)
Weight(including bracket) 20 lb(9 kg)
Operating Temperature -22°C to 122°C(-30°C to 50°C)
Storage Temperature -40°F to 185°F(-40°C to 85°C)
Enclosure Rating Type 3R
Agency Approvals cULus listed for United States and Canada under file
number E354307,FCC Part 15.
yr3r:+tic,ha>>�is