Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
Untitled
City of Arcadia, CA Permit NO. SOLR-20-1820 Development Services Department Permit Type:Solar 240 West Huntington Drive,Post Office Box 60021 Work Classification:Solar-Residential Arcadia,CA 91066-6021 (626)574-5416 Permit Status:Issued .ARCA DIA Issue Date:11/04/2020 ( Expiration: 11/04/2021 Addr NO. Dir Prefix Street Name Street Suffix Unit City,State,Zip Parcel Number 119 EL DORADO ST B Arcadia,CA 91006-3826 5779003069 Contacts KARTHIKEYA NATARAJAN Owner TESLA ENERGY* Contractor 119 EL DORADO ST B 3055 Clearview Way,San Mateo,CA 94402 (323)240-3174 888104 Description:ROOF MOUNTED SOLAR SYSTEM 21 Valuation: $ 0.00 Tenant MODULES/OPTIMIZERS, 1 INVERTER, NEW 125 A LOAD CENTER Total Sq Feet: 0.00 Plan Check# Plan# Fees Amount Payments Amount Paid Building Plan Check Fee Residential $100.00 Total Fees $324.72 Distribution Panel $16.48 Cash/Receipt#REC-05958-20 $324.72 Electrical Permit Issuance Fee $47.01 Amount Due: $0.00 Inverters $77.78 Panels $82.45 Solid Waste Management Fee 2 $1.00 Total: $324.72 l 02-21 —20 CALLS FOR INSPECTIONS IRequest for inspection by telephone at 626-574-5450. Leave a message Nv requesting the address,timeframe and what inspection item is needed. This permit/plan review expires by time limitation and becomes null and void if the work authorized by the permit is not commenced within 180 days from the date of issuance or if the permit is not obtained within 180 days from the date of plan submittal.This permit expires and becomes null and void if any work authorized by this permit is suspended or abandoned for 180 consecutive days or if no progressive work has been verified by a City of Arcadia building inspector for a period of 180 consecutive days. COMPLETED November 04, 2020 Issued By: Date November 04,2020 Page 1 of 1 • OFA• 0,0FOIN.I., .I PERMIT/PLAN REVIEW APPLICATION Development Services Department,240 West Huntington Drive,Post Office Box 60021 oe Arcadia, CA 91066-6021,(626)574-5416,Fax(626)447-9173 City of Arcadia LICENSED CONTRACTOR'S DECLARATION WORKERS'COMPENSATION DECLARATION ❑ I hereby affirm under penalty of perjury that I am licensed under provisions of I hereby affirm under penalty of perjury one of the following: Chapter 9(commencing with Section 7000,of Division 3 of the Business and Professions Code,and my license is in full force and effect. 0 I have and will maintain a certificate of consent to self-insure for workers' License Class License No. Exp. Date compensation, as provided for by Section 3700 of the Labor Code, for the Signature of Contractor performance of the work for which this permit is issued. OWNER-BUILDER DECLARATION ❑ I have and will maintain workers'compensation insurance,as required by Section 0 I hereby affirm under penalty of perjury that I am exempt from the Contractors 3700 of the Labor Code,for the performance of the work for which this permit License Law for the following reason(Section 7031.5,Business and Professions is issued.My workers'compensation insurance carrier and policy numbers are: Code.Any city or county which requires a permit to construct,alter,improve, Carrier demolish,or repair any structure,prior to its issuance,also required the applicant Policy Number for such permit to file a signed statement that he or she is licensed pursuant to the provisions of the Contractors License Law(Chapter 9(commencing with Section (This section need not be completed if the permit is for one hundred dollars or less) 7000)of Division 3 of the Business and Professions Code)or that he or she is ❑ I certify that in the performance of the work for which this permit is issued,I shall exempt there from and the basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a permit subjects the applicant to a civil not employ any person in any manner so as to become subject to the workers' penalty of not more than five hundred dollars($500)): compensation Laws of California,and agree that if I should become subject to the workers'compensation provisions of Section 3700 of the Labor Code,I shall ❑I, as owner of the property, or my employees with wages as their sole forthwith comply with those provisions. compensation,will do the work,and the structure is not intended or offered for sale(Section 7044,Business and Professions Code:The Contractors License Date Signature Law does not apply to an owner of property who builds or improves thereon, or who does such work himself or herself or through his or her own employees,provided that such improvements are not intended or offered for WARNING: Failure to secure Workers'Compensation coverage is unlawful, sale.If,however,the building or improvement is sold within one(1)year of and shall subject an employer to criminal penalties and civil fines up to one completion,the owner-builder will have the burden of proving that he or she hundred thousand dollars($100,000),in addition to the cost of compensation, did not build or improve for the purpose of sale). damages as provided for in Section 3706 of the Labor Code, interest, and attorney's fees. ❑I, as owner of the property, am exclusively contracting with licensed contractors to construct the project(Section 7044,Business and Professions Code:The Contractors License Law does not apply to an owner of property CONSTRUCTION LENDING AGENCY who builds or improves thereon,and who contracts for such projects with a I hereby affirm under penalty of perjury that there is a construction lending agency contractor(s)licensed pursuant to the Contractors License Law). for the performance of the work for which this permit is issued (Section 3097, Civil Code). ❑ I am exempt under Section 7044,Business and Professions Code,for this reason: Lender's Name Date Signature Lender's Address IMPORTANT: APPLICATION IS HEREBY MADE TO THE BUILDING OFFICIAL FOR A PERMIT SUBJECT TO THE CONDITIONS AND RESTRICTIONS SET FORTH ON THIS APPLICATION AND THE FOLLOWING: 1. The City's approved plans and permit inspection card must remain on the job site for use by City inspection personnel. 2. Final inspection of the work authorized by this permit is required.A Certificate of Occupancy must be obtained prior to use and occupancy of new buildings and structures. 3. Per South Coast Air Quality Management District(AQMD)regulations,renovation and remodeling work that results in the removal,stripping,or altering of asbestos containing materials requires an asbestos survey and removal prior to disturbing the asbestos.Please contact AQMD at(909)396-2000 for further information. Name Title PRINT NAME I certify that I have read this application and state that the above information is correct and that I am the owner or duly authorized agent of the owner. I agree to comply with all City ordinances and State Laws relating to building construction. I hereby authorize representatives of the City of Arcadia to enter upon the above-mentioned property for inspection purposes. Signature Date 4 k Zg f.IM! • fort,!i AFFIDAVIT SELF-CERTIFICATION FOR COMPLIANCE OF SMOKE ALARMS AND CARBON MONOXIDE ALARMS Property Address: I ` C S\ dO(CO o Permit Number: LZ- 24)-(c9- Brief cBrief Job Description: S 0\aY Number of smoke alarms installed: q 7-1 Number of carbon monoxide alarms installed: When alterations, repairs or additions requiring a permit occur, or sleeping rooms are created, Smoke alarms shall be installed in each sleeping room, and outside each separate sleeping area in the immediate vicinity of the bedrooms, and on each additional story of the dwelling, including basements and habitable attics as required by Section R314 of the 2016 California Residential Code (CRC) and California Health and Safety Code Section 13113.7. For dwellings or sleeping units containing fuel burning appliances or having attached garages, carbon monoxide alarms shall be installed outside each separate sleeping area in the immediate vicinity of the bedrooms, and on each additional story of the dwelling, including basements as required by Section R315 of the of the 2016 California Residential Code (CRC). Multi-purpose alarms (combination carbon monoxide and smoke alarms) may be used. All alarms shall comply with requirements for listing and approval by the Office of the State Fire Marshal. http://osfm.fire.ca.qov/licensinglistings/licenselistinq bml searchcotest.php As owner of the above referenced property, I hereby certify that the smoke alarms and carbon monoxide alarms have been installed in accordance with the manufacturer's instructions and in compliance with the code sections referenced above. I declare under penalty of perjury that the foregoing is true and correct, and that this declaration was executed on (Date) at Arcadia, California. Owner's Name (printed/typ d): t�t_ r `0- N f� V , Signature of Owner: ;,4 1 This affidavit must be returned to the City of Arcadia inspector prior to final inspection SMOKE ALARM AND CARBON MONOXIDE ALARM LOCATIONS Guest Room o 534—j—-------- -4 Bathroom V Storage (-17\-----.. Family Room Garage FIRST FLOOR PLAN Cr = SMOKE ALARM = CARBON MONOXIDE ALARM 1.---T: ® Mstr Rath PMaster Bedroom r--- Dining Room Kitchen Ipl-ril l3nth C il°a 5 Closet Hall ( Closet ,-- Closet Family Room - C. ( — Bedroom Bedroom SECOND FLOOR PLAN •=SMOKE ALARM II = CARBON MONOXIDE ALARM Version#86.3-1 NAS September 30,2020 RE: CERTIFICATION LETTER Project/Job#JB-9103703-00 Project Address: Natarajan Residence 119 El Dorado Street Arcadia,CA 91006 AHJ Arcadia SC Office Atwater Village Design Criteria: -Applicable Codes=Structure:2019 CEBC;PV:2019 CBC/CRC,ASCE 7-16,and 2018 NDS -Risk Category=II -Wind Speed=100 mph,Exposure Category C,Partially/Fully Enclosed Method -Ground/Roof Snow Load=0 psf -MP1:Roof DL=15.5 psf,Roof LL=17.5 psf -MP2:Roof DL=15.5 psf,Roof LL=17 psf -MP3:Roof DL=15.5 psf,Roof LL=17 psf Per Section 1613.1,W-(PV)/W-(exist roof)=3.4%,Increase Seismic Shear Load<10%,->[OKI To Whom It May Concern, A structural evaluation of loading was conducted for the above address based on the design criteria listed above. Based on this evaluation,I certify that the alteration to the existing structure by installation of the PV system meets the prescriptive compliance requirements of the applicable existing building and/or new building provisions adopted/referenced above. Additionally,I certify that the PV module assembly including all standoffs supporting it have been reviewed to be in accordance with the manufacturer's specifications and to meet and/or exceed all requirements set forth by the referenced codes for loading. The PV assembly hardware specifications are contained in the plans/docs submitted for approval. Installer shall verify existing roof framing is in suitable condition and does not exhibit any signs of structural damage which may diminish the capacity of its members or connections prior to commencement of PV installation.Installer verification of the mounting planes noted above is required because some or all of the framing was not observed prior to the structural evaluation performed for this report. Paul Zacher,P.E. Professional Engineer T:916.961.3960 x101 9ROFESSiO4, email: paul@pzse.com �1�ENNETti �y< � m No S3878 Exp.3-31-21 'k `RUCTl1RP� q.. TF OF CA\-\F� Tesla,Inc. T = 5 L n Version#86.3-1 NAS HARDWARE DESIGN AND STRUCTURAL EVALUATION RESULTS SUMMARY TABLES Landscape Hardware-Landscape Modules'Standoff Specifications Hardware X-X Spacing X-X Cantilever Y-Y Spacing Y-Y Cantilever Configuration Uplift DCR MP1 72" 24" 52" 24" Not-Staggered 39.7% MP2 72" 24" 52" 24" Not-Staggered 39.9% MP3 72" 24" 52" 24" Not-Staggered 39.9% Portrait Hardware-Portrait Modules'Standoff Specifications Hardware X-X Spacing X-X Cantilever Y-Y Spacing Y-Y Cantilever Configuration Uplift DCR MP1 64" 20" 52" 24" Not-Staggered 35.3% MP2 64" 20" 52" 24" Not-Staggered 35.5% MP3 64" 20" 52" 24" Not-Staggered 35.5% Mounting Plane Roof Pitch Qualification Results (Degrees) Member Evaluation Results MP1 28° Member Impact Check OK MP2 30° Member Impact Check OK MP3 30° Member Impact Check OK Tesla,Inc. Ti5 L n Version#86.3-1 NAS September 30,2020 RE: CERTIFICATION LETTER Project/Job#JB-9103703-00 Project Address: Natarajan Residence 119 El Dorado Street Arcadia,CA 91006 AHJ Arcadia SC Office Atwater Village Design Criteria: -Applicable Codes=Structure:2019 CEBC;PV:2019 CBC/CRC,ASCE 7-16,and 2018 NDS -Risk Category=II -Wind Speed=100 mph,Exposure Category C,Partially/Fully Enclosed Method -Ground/Roof Snow Load=0 psf -MP1:Roof DL=15.5 psf,Roof LL=17.5 psf -MP2:Roof DL=15.5 psf,Roof LL=17 psf -MP3:Roof DL=15.5 psf,Roof LL=17 psf Per Section 1613.1,W-(PV)/W-(exist roof)=3.4%,Increase Seismic Shear Load<10%,->[OK] To Whom It May Concern, A structural evaluation of loading was conducted for the above address based on the design criteria listed above. Based on this evaluation,I certify that the alteration to the existing structure by installation of the PV system meets the prescriptive compliance requirements of the applicable existing building and/or new building provisions adopted/referenced above. Additionally,I certify that the PV module assembly including all standoffs supporting it have been reviewed to be in accordance with the manufacturer's specifications and to meet and/or exceed al requirements set forth by the referenced codes for loading. The PV assembly hardware specifications are contained in the plans/docs submitted for approval. Installer shall verify existing roof framing is in suitable condition and does not exhibit any signs of structural damage which may diminish the capacity of its members or connections prior to commencement of PV installation.Installer verification of the mounting planes noted above is required because some or all of the framing was not observed prior to the structural evaluation performed for this report. Paul Zacher,P.E. Professional Engineer T:916.961.3960 x101 QROFESSION email: paul@pzse.com �e KENNETH I..q `�A c47 `-s, i m X No.S3878 \Exp.3-31-21 * e q„STRUCTIgtoP�\ F OF CALF Tesla,Inc. T E. S L n Version#86.3-1 NAS HARDWARE DESIGN AND STRUCTURAL EVALUATION RESULTS SUMMARY TABLES Landscape Hardware-Landscape Modules'Standoff Specifications Hardware X-X Spacing X-X Cantilever Y-Y Spacing Y-Y Cantilever Configuration Uplift DCR MP1 72" 24" 52" 24" Not-Staggered 39.7% MP2 72" 24" 52" 24" Not-Staggered 39.9% MP3 72" 24" 52" 24" Not-Staggered 39.9% Portrait Hardware-Portrait Modules'Standoff Specifications Hardware X-X Spacing X-X Cantilever Y-Y Spacing Y-Y Cantilever Configuration Uplift DCR MP1 64" 20" 52" 24" Not-Staggered 35.3% MP2 64" 20" 52" 24" Not-Staggered 35.5% MP3 64" 20" 52" 24" Not-Staggered 35.5% Mounting Plane Roof Pitch Qualification Results (Degrees) Member Evaluation Results MP1 28` Member Impact Check OK MP2 30° Member Impact Check OK MP3 30° Member Impact Check OK Tesla,Inc. T = 5 L n PITCH:28 ARRAY PITCH:28 _L ELECTRICAL EQUIPMENT TO BE 119 0 Dorado %will MP1 AZIMUTH:179 ARRAY AZIMUTH:179 MOUNTED ON.WALL MATERIAL Flat Cement Tile STORY:2 Stories � aw�.. "o"aH01on E, PITCH:30 ARRAY PITCH:30 MP2 AZIMUTH:89 ARRAY AZIMUTH:89 MATERIAL:Flat Cement Tile STORY:2 Stories PITCH:30 ARRAY PITCH:30 1 '�® MP3 AZIMUTH:269 ARRAY AZIMUTH:269 �., MATERIAL:Flat Cement Tile STORY:2 Stories ;,11. ,..... i 1©� ro, --, . ... . _ , . „ • I >� '4 0►, LEGEND Ayr„. Ii 'r•,1 l®I (E)UTILITY METER & WARNING LABEL 1 IN' 1 ' -` •' ri INVERTER W/INTEGRATED DC DISCO All & WARNING LABELS j' //y MP3\l'- '� DC DISCONNECT WARNING LABELS V ., \ •� &IAI AC DISCONNECT&WARNING LABELS // 1 1 Ii DC JUNCTION/COMBINER BOX&LABELS / AM Q DISTRIBUTION PANEL&LABELS ea 1:1 n LOAD CENTER &WARNING LABELS O DEDICATED PV SYSTEM METER J, ❑ n RAPID SHUTDOWN O STANDOFF LOCATIONS ❑ CONDUIT RUN ON EXTERIOR • CONDUIT RUN ON INTERIOR FOR ATTACHMENT ONLY — GA1E/FENCE 0 HEAT PRODUCING VENTS ARE RED ,:ONETn <. ' \ INTERIOR EQUIPMENT IS DASHED ��Q�EHwE Err r'1Fy I-....'-1 0 B/ 9 m K ! No.SJPIP A , 5 "," * SITE PLAN N \� � Ci) 9 OF rLIO__ SScale:1/16"=1' w E 01' 16' 32' \ .4"�� S CONTAINED 1I€NTMA lI a JB-9103703 00 K R HIKEYA NATARAJAN 714KW PV ARRAY Ma thew Fisher IEIETIT tr WOE ERI>FPT 1E9A INC...NOR mow=EN T S L n 91N1 IT OE=USED N MOLE CO N ZEP Mighty Hook 119 El Dorado Street PART TO DOERS QIISwE 1E RECPers Arcadia, CA 91006 9RGWZA1wt DEM N CONNECTION w1R O ER 1E SNE me USE OF Of RE4EC11E (21)Hanwha Q-CELLS /Q.Peak DUO BLK-G6+ 340 NM sia xwcr DATE: s Crar 1ESILA "1°"`" "° 62672015013 a 9/0/2020 SdorEdae Technologies Ltd. I SE7600H-US(240V1 SITE PLAN