Loading...
HomeMy WebLinkAboutUntitled •.%, City of Arcadia, CA Permit NO. SOLR-20-1728 Development Services Department Permit Type:Solar 240 West Huntington Drive,Post Office Box 60021 Arcadia,CA 91066-6021 Work Classification:Solar-Residential Over 10 KV (626)574-5416 Permit Status:Estimate ARCADIA Issue Date: I Expiration: Addr NO. Dir Prefix Street Name Street Suffix Unit City,State,Zip Parcel Number 1016 S FIFTH AVE Arcadia,CA 91006-4330 5780007011 Contacts PRIMROSE CHO Owner TESLA ENERGY* Contractor 1016 S FIFTH 3055 Clearview Way,San Mateo,CA 94402 (626)862-0220 (323)240-3174 888104 ir Description: ROOF MOUNT PV SYSTEM WITH 2 ESS,36 Valuation: $ 0.00 Tenant MODULES/MICRO-INVERTERS,NEW 200 AMP LOAD CENTER, BREAKER BOX, 2 ESS Total Sq Feet: 0.00 Plan Check# Plan# Fees Amount Payments Amount Paid Battery Storage Device $106.00 Total Fees $430.72 Building Plan Check Fee Residential $100.00 Cash/Receipt#REC-05841-20 $430.72 Distribution Panel $16.48 Electrical Permit Issuance Fee $47.01 Amount Due: $0.00 Inverters $77.78 ~ Panels $82.45 Solid Waste Management Fee 2 $1.00 Total: $430.72 1 / Z4--Z4 CALLS FOR INSPECTIONS Request for inspection by telephone at 626-574-5450. Leave a message FI/44-v fir_. requesting the address,timeframe and what inspection item is needed. This permit/plan review expires by time limitation and becomes null and CO al void from if the the work dateof authorizedissuanceor byif thethe permitpermit isis notnot commenced obtained withinwithin180 180days days �p from the date of plan submittal.This permit expires and becomes null and ED void if any work authorized by this permit is suspended or abandoned for 180 _ t consecutive days or if no progressive work has been verified by a City of 71- �j 1,& u,56 , Arcadia building inspector for a period of 180 consecutive days. Issued By: Date October 21,2020 Page 1 of 1 (14"-'4'%c„,,spon,w4. '± PERMIT/PLAN REVIEW APPLICATION • 10,1?' Development Services Department,240 West Huntington Drive,Post Office Box 60021 " Arcadia, CA 91066-6021,(626) 574-5416,Fax(626)447-9173 City of Arcadia LICENSED CONTRACTOR'S DECLARATION WORKERS'COMPENSATION DECLARATION ❑ I hereby affirm under penalty of perjury that I am licensed under provisions of I hereby affirm under penalty of perjury one of the following: Chapter 9(commencing with Section 7000,of Division 3 of the Business and Professions Code,and my license is in full force and effect. ❑ I have and will maintain a certificate of consent to self-insure for workers' License Class License No. Exp. Date compensation, as provided for by Section 3700 of the Labor Code, for the Signature of Contractor performance of the work for which this permit is issued. OWNER-BUILDER DECLARATION 0 I have and will maintain workers'compensation insurance,as required by Section ❑ I hereby affirm under penalty of perjury that I am exempt from the Contractors 3700 of the Labor Code,for the performance of the work for which this permit License Law for the following reason(Section 7031.5,Business and Professions is issued.My workers'compensation insurance carrier and policy numbers are: Code.Any city or county which requires a permit to construct,alter,improve, Carrier demolish,or repair any structure,prior to its issuance,also required the applicant Policy Number for such permit to file a signed statement that he or she is licensed pursuant to the provisions of the Contractors License Law(Chapter 9(commencing with Section (This section need not be completed if the permit is for one hundred dollars or less) 7000)of Division 3 of the Business and Professions Code)or that he or she is Ithat in the performance of the work for which this tis issued,I shall exempt there from and the basis for the alleged exemption. Any violation of ❑ certifyarm' Section 7031.5 by any applicant for a permit subjects the applicant to a civil not employ any person in any manner so as to become subject to the workers' penalty of not more than five hundred dollars($500)): compensation Laws of California,and agree that if I should become subject to the workers'compensation provisions of Section 3700 of the Labor Code,I shall ❑I, as owner of the property, or my employees with wages as their sole forthwith comply with those provisions. compensation,will do the work,and the structure is not intended or offered for sale(Section 7044,Business and Professions Code:The Contractors License Date Signature Law does not apply to an owner of property who builds or improves thereon, or who does such work himself or herself or through his or her own employees,provided that such improvements are not intended or offered for WARNING: Failure to secure Workers'Compensation coverage is unlawful, sale.If,however,the building or improvement is sold within one(1)year of and shall subject an employer to criminal penalties and civil fines up to one completion,the owner-builder will have the burden of proving that he or she hundred thousand dollars($100,000),in addition to the cost of compensation, did not build or improve for the purpose of sale). damages as provided for in Section 3706 of the Labor Code, interest, and attorney's fees. ❑I, as owner of the property, am exclusively contracting with licensed contractors to construct the project(Section 7044, Business and Professions Code:The Contractors License Law does not apply to an owner of property CONSTRUCTION LENDING AGENCY who builds or improves thereon,and who contracts for such projects with a I hereby affirm under penalty of perjury that there is a construction lending agency contractor(s)licensed pursuant to the Contractors License Law). for the performance of the work for which this permit is issued (Section 3097, Civil Code). 0 I am exempt under Section 7044,Business and Professions Code,for this reason: Lender's Name Date Signature Lender's Address IMPORTANT: APPLICATION IS HEREBY MADE TO THE BUILDING OFFICIAL FOR A PERMIT SUBJECT TO THE CONDITIONS AND RESTRICTIONS SET FORTH ON THIS APPLICATION AND THE FOLLOWING: 1. The City's approved plans and permit inspection card must remain on the job site for use by City inspection personnel. 2. Final inspection of the work authorized by this permit is required.A Certificate of Occupancy must be obtained prior to use and occupancy of new buildings and structures. 3. Per South Coast Air Quality Management District(AQMD)regulations,renovation and remodeling work that results in the removal,stripping,or altering of asbestos containing materials requires an asbestos survey and removal prior to disturbing the asbestos. Please contact AQMD at(909)396-2000 for further information. Name Title PRINT NAME I certify that I have read this application and state that the above information is correct and that I am the owner or duly authorized agent of the owner. I agree to comply with all City ordinances and State Laws relating to building construction. I hereby authorize representatives of the City of Arcadia to enter upon the above-mentioned property for inspection purposes. Signature Date Version#86.1 -1 NAS September 26,2020 RE: CERTIFICATION LETTER Project/Job#JB-9103687-00 Project Address: Cho Residence 1016 Fifth Ave Arcadia,CA 91006 AHJ Arcadia SC Office Atwater Village Design Criteria: -Applicable Codes=Structure:2019 CEBC;PV:2019 CBC/CRC,ASCE 7-16,and 2018 NDS -Risk Category=II -Wind Speed=100 mph,Exposure Category C,Partially/Fully Enclosed Method -Ground/Roof Snow Load=0 psf -MP1:Roof DL=15.5 psf,Roof LL=20 psf -MP8,9,11:Roof DL=15.5 psf,Roof LL=20 psf -MP2:Roof DL=15.5 psf,Roof LL=20 psf -MP4:Roof DL=15.5 psf,Roof LL=20 psf -MP5:Roof DL=15.5 psf,Roof LL=20 psf -MP6:Roof DL=15.5 psf,Roof LL=20 psf -MP7:Roof DL=15.5 psf,Roof LL=20 psf Per Section 1613.1,W-(PV)/W-(exist roof)=2.5%,Increase Seismic Shear Load<10%,->[OI To Whom It May Concern, A structural evaluation of loading was conducted for the above address based on the design criteria listed above. Based on this evaluation,I certify that the alteration to the existing structure by installation of the PV system meets the prescriptive compliance requirements of the applicable existing building and/or new building provisions adopted/referenced above. Additionally,I certify that the PV module assembly including all standoffs supporting it have been reviewed to be in accordance with the manufacturer's specifications and to meet and/or exceed all requirements set forth by the referenced codes for loading. The PV assembly hardware specifications are contained in the plans/docs submitted for approval. Installer shall verify existing roof framing is in suitable condition and does not exhibit any signs of structural damage which may diminish the capacity of its members or connections prior to commencement of PV installation.Installer verification of the mounting planes noted above is required because some or all of the framing was not observed prior to the structural evaluation performed for this report. Paul Zacher,P.E. • • _ Professional Engineer T:916.9613960 x101 CITY OsF,%RCADDe QFtOFESSIONy7 ��� ��NNE TH Iq (C email: paul@pzs�o> 'i0pipent Services Department �`J. y APPRO\TFI) ��• FP ._ • This set of plans)tfrd sl)ecitications must he kept �Exp.331-21 tt No.S3878 on the job at all tunes and no changes or alterations -., sr shall he made e\ceptl)3.the (;lfllfll•n��1). qT RF c '-P �� • The Stam)ir ision. F of ca-\F° Stamplog oCthis[)!;m and sprcllication shall not be held to permit or to!.c;in iiplam.al of the violation of ant prof•ii�ffis an di Isrdioancr or state lan Tesla,Inc. . , Version#86.1 -1 NAS HARDWARE DESIGN AND STRUCTURAL EVALUATION RESULTS SUMMARY TABLES Landscape Hardware-Landscape Modules'Standoff Specifications Hardware X-X Spacing X-X Cantilever Y-Y Spacing Y-Y Cantilever Configuration ' Uplift DCR MP1 72" 24" 52" 24" Not-Staggered 47.2% MP8,9,11 72" 24" 52" 24" Not-Staggered 47.2% MP2 72" 24" 52" 24" Not-Staggered 47.2% MP4 72" 24" 52" 24" Not-Staggered 47.2% MP5 72" 24" 52" 24" Not-Staggered 47.2% MP6 72" 24" 52" 24" Not-Staggered 47.2% MP7 72" 24" 52" 24" Not-Staggered 47.2% Portrait Hardware-Portrait Modules'Standoff Specifications Hardware X-X Spacing X-X Cantilever Y-Y Spacing Y-Y Cantilever Configuration I Uplift DCR MP1 64" 20" 52" 24" Not-Staggered 41.9% -- MP8,9,11 64" 20" 52" 24" Not-Staggered 41.9% MP2 64" _ 20" 52" 24" Not-Staggered 41.9% _ _ MP4 64" 20" 52" 24" Not-Staggered 41.9% MP5 64" 20" 52" 24" Not-Staggered 41.9% MP6 64" 20" 52" 24" Not-Staggered 41.9% MP7 64" 20" 52" 24" Not-Staggered 41.9% Roof Pitch Qualification Results Mounting Plane (Degrees) Member Evaluation Results MP1 18° _ Member Impact Check OK MP8,9,11 18° Member Impact Check OK MP2 18° Member Impact Check OK . ._ MP4 18° Member Impact Check OK MP5 18° Member Impact Check OK MP6 18° Member Impact Check OK MP7 18° Member Impact Check OK Tesla,Inc.