Loading...
HomeMy WebLinkAboutCOMM-20-0405 IF 3 Permit NO. Comm-20-0405 f ` 'S City of Arcadia, CA " r< Development Services Department Permit Type:Commercial 1 240 West Huntington Drive,Post Office Box 60021 . , Arcadia,CA 91066-6021Work Classification:-_Commercial:-Add/Alt a.F: a (626)574-5416 Permit Status:Issued A RCA D I Issue Date:05/28/2020 1 Expiration: 09/08/2020 Addr NO. Dir Prefix Street Name Street Suffix Unit City,.State,Zip Parcel Number 145 E HUNTINGTON DR Arcadia, CA 91006-3212 5773010014 rwau a. ,ate.-_aat,�.�._�r�a+,xs.,,• >_..:mss s�,.g__._n.., .P ,�..,..me .-. ww. .�.c .as- ,:a..�' :. ae _a rae s xa�.:. .W 4rn..w.a�.:�.+�•�.,:ea. t%:� Contacts . VINCENT MARKESE Owner CRT RESTORATION INC* Contractor 375 LONGDEN AVE 8251 LA PALMA AVE AVE 402, BUENA PARK,CA 90620 1626)215-1252 (714)487-1749 1065918 RICK NICHOLSON Contractor (818)395-7099 fx M^-.sw.., a,. .;:••_...,::En-:aa. .' ec*.rr+.>s•�+w-.. .. ,,.a..ma--,... .;.tea'ar.�„xa ., ae•;,.:a:.,•:.;. as :;w w., "w: �.c .. Description:DEMO EXTERIOR PATIO CLAY BRICK WALL AND Valuation: $ 30,000.00 t Tenant MATT DENNYS REPLACE WITH 2X6 FRAMING WITH BRICK VENEER AT MATT DENNYS ; Total Sq Feet: 0.00 I Plan Check#20-405 Plan#268 t. - d _t *,• Fees Amount Payments Amount Paid Accessibility Plan Check $53.78 Total Fees $1,508.72 Accessiblity Building Permit $55.15 Cash/Receipt q REC-04556-20 $670.31 Building Issuing Fee $47.01 Cash/Receipt N REC-04067-20 $838.41 Building Permit Fees $551.50 Building Plan Review Fee $358.48 Amount Due: $0.00 Cal Green Plan Check $35.85 Commercial T.I.Fire Plan Chk. $280.00 Energy Plan Review Fee $110.30 Grlidn ante Building $2.00 El COM ,,{ ��Solid Waste Management Fee $6.25 ��11rStrong Motion Inst.Program Com $8.40 INSPECTIONS Request for inspection by telephone at 626-574-5450. Leave a message Total: $1,508.72 requesting the address,timeframe and what inspection item is needed. • This permit/plan review expires by time limitation and becomes null and void if the work authorized by the permit is not commenced within 180 days from the date of issuance or if the permit is not obtained within 180 days from the date of plan submittal.This permit expires and becomes null and void if any work authorized by this permit is suspended or abandoned for 180 consecutive days or if no progressive work has been verified by a City of Arcadia building inspector for a period of 180 consecutive days. May 28, 2020 Issued By: Date May 28,2020 Page 1 of 1 `4°uFORRy,,,, si T.k PERMIT/PLAN REVIEW APPLICATION __k. fiz IP IERE of �� Development Services Department,240 West Huntington Drive,Post Office Box 60021 m„oi.Y of Arcadia, CA 91066-6021, (626) 574-5416,Fax(626) 447-9173 City of Arcadia LICENSED CONTRACTOR'S DECLARATION WORKERS'COMPENSATION DECLARATION I hereby affirm under penalty of perjury that I am licensed under provisions of I hereby affirm under penalty of perjury one of the following: Chapter 9(commencing with Section 7000,of Division 3 of the Business and 1 d Professions Code,and my license is in full force and effect. ❑ I have and will maintain a certificate of consent to self-insure for workers' License Class License No. Exp. Date compensation, as provided for by Section 3700 of the Labor Code, for the Signature of Contractor performance of the work for which this permit is issued. OWNER-BUILDER DECLARATION ❑ I have and will maintain workers'compensation insurance,as required by Section ❑ I hereby affirm under penalty of perjury that I am exempt from the Contractors 3700 of the Labor Code,for the performance of the work for which this permit License Law for the following reason(Section 7031.5,Business and Professions is issued.My workers'compensation insurance carrier and policy numbers are: Code.Any city or county which requires a permit to construct,alter,improve, Carrier demolish,or repair any structure,prior to its issuance,also required the applicant for such permit to file a signed statement that he or she is licensed pursuant to the Policy Number provisions of the Contractors License Law(Chapter 9(commencing with Section (This section need not be completed if the permit is for one hundred dollars or less) 7000)of Division 3 of the Business and Professions Code)or that he or she is exempt there from and the basis for the alleged exemption. Any violation of ❑ I certify that in the performance of the work for which this permit is issued,I shall Section 7031.5 by any applicant for a permit subjects the applicant to a civil not employ any person in any manner so as to become subject to the workers' penalty of not more than five hundred dollars($500)): compensation Laws of California,and agree that if I should become subject to the workers'compensation provisions of Section 3700 of the Labor Code,I shall ❑I, as owner of the roe forthwith comply with those provisio property,rty, or my employees with wages as their sole _ compensation,will do the work,and the stricture is not intended or offered for ' sale(Section 7044,Business and Professions Code:The Contractors License Date. le tS��ignatur-"e . -- ,�—. Law does not apply to an owner of property who builds or improves thereon, or who does such work himself or herself or through his or her own employees,provided that such improvements are not intended or offered for WARNING: Failure to secure Workers'Compensation coverage is unlawful, sale.If,however,the building or improvement is sold within one(1)year of and shall subject an employer to criminal penalties and civil fines up to one completion,the owner-builder will have the burden of proving that he or she hundred thousand dollars($100,000),in addition to the cost of compensation, did not build or improve for the purpose of sale). damages as provided for in Section 3706 of the Labor Code, interest, and attorney's fees. - - ❑I, as owner of the property, am exclusively contracting with licensed contractors to construct the project(Section 7044,Business,and Professions Code:The Contractors License Law does not apply to an owner of property CONSTRUCTION LENDING AGENCY who builds or improves thereon, and who contracts for such projects with a I hereby affirm under penalty of perjury that there is a construction lending agency contractor(s)licensed pursuant to the Contractors License Law). for the performance of the work for which this permit is issued (Section 3097, Civil Code). ❑ I am exempt under Section 7044,Business and Professions Code,for this reason: Lender's Name Date Signature Lender's Address IMPORTANT: APPLICATION IS HEREBY MADE TO THE BUILDING OFFICIAL FOR A PERMIT SUBJECT TO THE CONDITIONS AND RESTRICTIONS SET FORTH ON THIS APPLICATION AND THE FOLLOWING: 1. The City's approved plans and permit inspection card must remain on the job site for use by City inspection personnel. 2. Final inspection of the work authorized by this permit is required.A Certificate of Occupancy must be obtained prior to use and occupancy of new buildings and structures. 3. Per South Coast Air Quality Management District(AQMD)regulations,renovation and remodeling work that results in the removal,stripping,or altering of asbestos containing materials requires an asbestos survey and removal prior to disturbing the asbestos.Please contact AQMD at(909)396-2000 for further information. n Ine LCLiA(Zig �l�t �Tc PRINT NAME Title D1 e–Q-(.t— Of— lemay,) rtify that I have read this application and state that the above information is correct and that I am the owner or duly authorized agent of the owner. gree to comply with all City ordinances and State Laws relating to building construction. I hereby authorize representatives of the City of adia to enter upon the above-mentioned property for inspection purposes. // �l (-7.3 Signature ( Date I yS` E - �Nn�� -� NOTES Building Inspections Date Insp. Plumbing Inspections Date Insp. r7 - O 100. Setbacks 210. Under fir./bldg.drain !� 101. Rough grade 211. Copper underslab 102. Figs.&forms 212. Rough plumbing 103. Pre-slab 213. Rough gas 104. Floor joists 214. Shower pan 105. Steel 215. Water heater 106. Grout lift 216. Roof drains 107. Shear nailing 217. Building sewer 108. Diaph nailing $' 218. Water service 109. Roof nailing 219. Final gas 110. Framing `7.6 .2.O 4" --220. Fixtures _- 111. Occ./Area Sept.Wall 221. Final plumbing 112. Sound walls 222. Sewer cap/demo. 113. T-bar a rid 114. Insulation-Flr. Pool Inspections Date Insp. 115. Insulation-Wall 240. Excavation/steel 116. Insulation-Ceil. 241. Rough plumbing 117. Drywall nailing 21.4.2p '' 242. Light shell/bonding 118. Interior lath 243. Underground conduit 119. Exterior lath 8.(Z. � 244. P-trap 120. Finish grade 245. Gas line&test 121. Final building o 5 246. Fence,gates&signs 122. Anal demo/lot clear 247. Pool heater 248. Anal electric Electrical Inspections Date Insp. 249. Anal'lumbin' 150. Power pole 250. Pool cover 151. Sales lot lighting 251. Pool final 152. Undenround conduit 153. Underslab conduit Reroof Inspections I Date I Insp. 154. UFER ground 270. Pre-reroof insp. 155. Water ground 271. Roof framing 156. Rough electrical 21, "`*?` 272. Sheathing nailing 157. Fixtures _ 273. Anal reroof 158. G.F.C.I. 159. Es at.bondin. Sign Inspections I Date I Insp. 160. Service panel 280. Setback/overhang 161. Final electric /o•5.*Zo Footing 282. Conduit/wirin. • Mechanical Inspections Date Insp. 283. Disconnect 180. Venting/flue 284. Final sign 181. Furnace/A.C. 182. Rouch HVAC Miscellaneous lnsp. Date I Insp. 183. Are dampers 290. Are alarm 184. Furnace compartment 291. Underground supply 185. Combustion air 292. Are sprinklers 186. Smoke detectors 293. Monitor system 187. Metal F.P.rough 294. Hood dry chem. 188. Compressor setback 295. Anal _ 189. Commercial hood 190. Duct shaft Sewers&Offsite Insp. I Date I Insp. 191. Anal mechanical 300. Lateral(main to P/L) - 301. Saddle/Y Block Wall Inspections - Date Insp. 302. CessI.ol filled 200. Footings 303. Sidewalk 201. Steel/rebar 304. Driveway 202. Grout lift 305. Curb replacement - 203. Anal wall 306. Trash bin rEPUTV 1 0NSP C1T*N SEVil cE Ilii) DEPT. OF BLDG. & SAEETY CITY OF Arcadia 25121 DE SALLE ST, LAGUNA HILLS, CA 92653 COUNT" OF J ___ 1 - 800 - DEPUTY 1 = 1 = 800 - 337 -3881 • SPECIAL INSPECTION REPORT Building Permit No. COMM-20-0405 Job. No. • Date?/72020 Job Indentification/Address 145 East Huntington Drive — ____ General Contractor/Address Rick Nicholson __ __ -- Sub - Contractor/Address --- -- Structural Engineer/Address William Runyan Arch. _�— �_ REINFORCED CONCRETE MASONRY HI-TENSILE BOLTING CHEMICAL ANCHORS _ PRESTRESSED CONCRETE_ WELDING GYPSUM CONCRETE OTHER Titan Bolts WELDER 1 RECEIPT NUMBER WELDER 1 RECEIPT NUMBER I DATE OF INSPECTIONDESCRIPTION OF WORK INSPECTED 7/7/2020 ON SITE FOR OBSERVATION OF INSTALLATION OF(7) 1/2"X 6"TITEN BOLTS AS PER THE APPROVED PLANS. • i , t -ALL HOLES WERE DRILLED TO A DIAMETER OF 1/2"AND A MINIMUM DEPTH OF 8". -ALL HOLES WERE DRY, BRUSHED,AND AIR BLOWN CLEAN PRIOR TO INSTALLATION. `• -ALL BOLTS WERE INSTALLED IN ACCORDANCE WITH THE MANUFACTURER'S _ . RECOMMENDED PROCEDURES. ALL(7) BOLTS ARE VERIFIED AS COMPLETE PER THE APPROVED PLANS TO THE • BEST OF MY KNOWLEDGE. REFERENCED PLAN SHEET A-2#2 HOURSSAMPLES • DATE Reg. OT Time In Time Out • Grout Mortar Concrete t3I°e1c Density •7/7/2020 412:50PM 1:30PM Prisms MEE .All inspections based on a minimum of 4 hours&over 4 hours-8 hours minimum.Any inspection extending past the noon hour will be billed as 8 MEMhour minimum.In addition,any inspectionextending past an 8 hour pe- i riod,or Saturday inspection will be billed at time and a half. I ATTORNEY'S FEES - If any action at law or in equity is brought to enforce or interupt the terms of this Contract, the prevailing party shall be entitled to reasonable attorney's fees,costs and necessary disbursements in addition to any other relief to which such party maybe entitled. SPECIAL INSPECTION REPORT Tyson Cerise Inspector's Name: Inspector's Signal re: I.D. No.ICC 8718432 has been filed and it states that the above work to th-. •- `*1 /••• ledge complies With the provisions otlithectn firm Building Code and meets approved plans and spec' -d:• Respectfully Submitted, Approved by: Project Superintendent