HomeMy WebLinkAboutSOLR-19-0138 (2) City of Arcadia,CA Permit NO.SOLR-19-0138
Development Services Department Permit Type:Solar
240 West Huntington Drive,Post Office Box 60021
Arcadia,CA 91066-6021 Work Classification:Solar-Residential
(626)574-5416 Permit Status:Issued
A RCA DIA Issue Date:01/22/2019 Expiration:07/21/2019
Addr NO. Dir Prefix Street Name Street Suffix Unit City,State,Zip Parcel Number
[861 Balboa DR Arcadia,CA 5777020013 mmow
Contacts
CHUONG,EDWIN T AND CHRISTINE T Owner PACIFIC STONEGATE INC dba:SOLAR Solar Contractor(C-46)
861 BALBOA DR,ARCADIA,CA 91007 VAST
(909)518-5107 CHRISTINE_CHUONG@YAHOO.COM 8727 LANYARD CT,RANCHO CUCAMONGA,CA 91730
(909)377-5477 965340
:,ate.. .sow
Description:ROOF MOUNT PV SYSTEM,NEW LOAD CENTER- Valuation: $0.00 Tenant
I 125 24 MOD/MICRO INVERTER
Total Sq Feet: 0.00 Plan Check# Plan
Lew, #
� t
Fees Amount Payments Amount Paid
Building Plan Check Fee Residential $50.00 Total Fees $324.72
Distribution Panel $16.48 Cash/Receipt#REC-00178-19 $324.72
Electrical Permit Issuance Fee $47.01
Amount Due: $0.00
Fire Plan Check Fee Residential $50.00
Inverters $77.78
Panels $$1.05 XP BRED
Solid Waste Management Fee 2 $1.00
Total: $324.72
CALLS FOR INSPECTIONS
Request for inspection by telephone at 626-574-5450. Leave a message
requesting the address,timeframe and what inspection item is needed.
This permit/plan review expires by time limitation and becomes null and
void if the work authorized by the permit is not commenced within 180 days
from the date of issuance or if the permit is not obtained within 180 days
from the date of plan submittal.This permit expires and becomes null and
void if any work authorized by this permit is suspended or abandoned for 180
consecutive days or if no progressive work has been verified by a City of
Arcadia building inspector for a period of 180 consecutive days.
January 22,2019
Issued By: Date
January 13,2020 Page 1 of 1
A P D L L D 4650E. ARROW HWY. STE.A7
STRUCTURAL MONTCLAIR. CA 91763
Structural Calculations for:
Edwin Choung Residence
7.84 kW AC Photovoltaic Array Addition
861 Balboa Dr.
Arcadia, CA 91007
Owner/Developer: 4,. Cj�,j,
SolarVast N. 'v�),c�t O�1
8727 Lar}I•arc �P t ` fop/�/ SQA ` (rti• ,4
a/A.• �j�i t c!)
Rancho Cucamon ,`P /� g/ /i •
�t St �y��. t�� `� �/•s/�tt�G�1 c��/t0i,
A �a, iryt, s 4/1 l J tht
c'4/ /�i�i„ c'� , ���/, �ti,, •
or, to pt fei/� c,)f, (het
J
January 28;c 9s'it�p ,/j/4/1,• �t/t.t444. '.N'0/.4 4
iPajp Ott
Job#: 19-1839 it" , /c t /10
01
01. 411
QROFEArit
SSi. )1
gg ter
N.. C75:95 j;
Jj EXP 6,301'0 Ay
d
VV/�•
C/�vOCI te• t Erb\ �
ICM.��`�
4 Page 1 of 5
APOLLO1 4650 E.ARROW HWY. STE.A7
STRUCTURAL
MONTCLAIR. CA 91763
SOLAR RESIDENTIAL ROOF/BUILDING CHECK - MAIN STRUCTURE
Check Photovoltaic Array Addition-2016 California Building Code(CBC)
Gravity Design Loads:
Roof Type: Conc.tile over 1/2"sheathing over rafters over 5/8"gypsum board
Live Load: 20.0 psf
Dead Load:
Roofing Material: 12.0 psf
Sheathing: 1.5 psf
Roof Framing Members: 2.5 psf
Drywall: 1.5 psf
Insulation: 1.0 psf
Miscellaneous: 1.5 psf
Solar Array&Rack System 2.88 psf ----Additional Load Applied
Roof Dead Load w/o Solar Array= 20.00 psf Over<50%of Roof Area
Roof Dead Load at Solar Array= 22.88 psf
Total Roof Load w/o Solar Array= 40.0 psf
Total Roof Load at Solar Array= 42.9 psf
Area of Solar Array Addition(for gravity check)= 210 ft2
Total Area of Affected Rafters(for gravity check)= 1500 ft2
Area of Solar Array Addition(for seismic check)= 210 ft2
Total Area of Affected Roof(for seismic check)= 1500 ft2
Check Additional Gravity Loads on Rafters:
Total Load Increase at Affected Rafters = 0.40 psf
%of Total Load Increase= 1.01% < 5.0% OK
Per CBC 3403A.3 Additional Solar Array Weight is Structurally
Acceptable
Check Additional Gravity Loads on Lateral Resisting System:
Dead Load Increase at Entire Roof= 0.40 psf
%Dead Load Increase on Entire Roof= 2.02% < 10.0% OK
Per CBC 3403A.4 Additional Solar Array Lateral Load is Structurally
Acceptable
Page 2 of 5
r 1
APOLLO 14650 E.ARROW HWY. STE.A7
STRUCTURAL
MONTCLAIR, CA 91763
SOLAR RESIDENTIAL ROOF/BUILDING CHECK - DETACHED UNIT
Check Photovoltaic Array Addition-2016 California Building Code(CBC)
Gravity Design Loads:
Roof Type: Conc.tile over 1/2"sheathing over rafters over 5/8"gypsum board
Live Load: 20.0 psf
Dead Load:
Roofing Material: 12.0 psf
Sheathing: 1.5 psf
Roof Framing Members: 2.5 psf
Drywall: 1.5 psf
Insulation: 1.0 psf
Miscellaneous: 1.5 psf
Solar Array&Rack System 2.88 psf ----Additional Load Applied
Roof Dead Load w/o Solar Array= 20.00 psf Over<50%of Roof Area
Roof Dead Load at Solar Array= 22.88 psf
Total Roof Load w/o Solar Array= 40.0 psf
Total Roof Load at Solar Array= 42.9 psf
Area of Solar Array Addition(for gravity check)= 210 ft2
Total Area of Affected Rafters(for gravity check)= 800 ft2
Area of Solar Array Addition(for seismic check)= 210 ft2
Total Area of Affected Roof(for seismic check)= 800 ft2
Check Additional Gravity Loads on Rafters:
Total Load Increase at Affected Rafters = 0.76 psf
%of Total Load Increase= 1.89% < 5.0% OK
Per CBC 3403A.3 Additional Solar Array Weight is Structurally
Acceptable
Check Additional Gravity Loads on Lateral Resisting System:
Dead Load Increase at Entire Roof= 0.76 psf
%Dead Load Increase on Entire Roof= 3.79% < 10.0% OK
Per CBC 3403A.4 Additional Solar Array Lateral Load is Structurally
Acceptable
Page 3 of 5
•
Sht: El
A P O [LU
4850 E. ARROW HWY, STE. A7 Date:
STRUCTURAL MONTCLAIR, CA 91763 0_
ROOF MOUNTED SOLAR PANELS - WORST CASE AT 2ND FLOOR
Earthquake Design per ASCE 7-16- 13.3.1
Design Parameters
Site Class= D Per Table 1613A.3.2 Latitude,deg Longitude,deg
Short Period S.A.,Ss= 2.655 2015 NEHRP Provisions 34.1344 -118.0598
Site Coefficient,Fa= 1.20 Table 1613A.3.3(1)
Sms=FaSs= 3.19 EQ 16A-37
Sps=2/3 Sms= 2.12 EQ 16A-39
Importance Factor,1,= 1.00 Section 13.1.3
Height of Equipment,z= 22.00 ft
Height of Roof,h= 22.00 ft
Weight of Panels to each Mount,Wp= 45.50 lbs
ap= 1.00 Table 13.6-1
Rp= 2.50 Table 13.6-1
Determine Fp,Seismic Design Force(STRENGTH LEVEL)
Fp=(0.4apSpsWp)(1+2z/h)/(Rp/Ip)= 46 lbs EQ 13.3-1
[Not Greater Than:] Fp=1.6S0SWplp= 155 lbs EQ 13.3-2
[Not Less Than:] Fp=0.3S05Wplp= 29 lbs EQ 13.3-3
Use Fp= 46 lbs at each Roof Mount Bracket
Page 4 of 5
•
Sht: W1
A P DL L 4650 E. ARROW HWY, STE.A7 Date:
SIR UCTURAL MONTCLAIR. CA 91763 A: --
ROOF MOUNTED SOLAR PANELS - WORST CASE AT 2ND FLOOR
Components and Cladding-Wind Load Design per ASCE 7-16,30.4.2-h<60 ft
Design Parameters
Design Wind Velocity(3s Gust),V= 110 mph
Wind Exposure= C
Mean Panel Height= 22.00 ft
Total Effective Area of Typical Array= 210 ft2
Panel Area to Each Support= 18.00 ft2
Angle of Panels= 18 degrees
a= 3 ft(3ft.Min.)
Determine Wind Force at Each Roof Mount
cin=0.00256 K,K,,Kd V2 I= 14.5 psf Load case 0.6'gh
K,= 0.92 Table 30.3-1,Page 317
Kz2= 1.0 Figure 26.8-1,Page 252-253
Kd= 0.85 Table 26.6-1,Page 250
1= 1.00
Internal Pressure Coeff.=GCP;= 0 +1-(Figure 6-5)
y=180°
GCP(Zone 1)= 0.45 -0.85 Per Figures 30.4-1 thru 30.4-7
GCP(Zone 2)= 0.45 -1.60 Per Figures 30.4-1 thru 30.4-7
GCP(Zone 3)= 0.45 -1.60 NO PANELS IN ZONE 3
p
(+)P=qh(GCP-GCP;)= 10.0 -23.3 psf,Positive Wind(10 psf min)-Worst Case
Lateral Load at Each Mount= 56 -129 lbs
Compression/Uplift at Each Mount= 171 -398 lbs
Roof Mount is attached to roof sheathing&roof members w/(1)5/16" x 4-1/2" Lag Bolt w/Min.3.5"thread
embed per SOLARVAST.
Allowable Loads for 5/16" Diameter Lag Screw per the 2015 NDS:
(Table 11.2A) Withdrawl= 266 lb/in x 3.5"embed x (Cd= 1.6)= 1490 lbs
(Table 11K) Shear= 120 lb x (Cd=1.6) = 192 lbs
SOLAR ARRAY ATTACHMENT METHOD IS STRUCTURALLY ACCEPTABLE.