Loading...
HomeMy WebLinkAboutDemo-21-0796 1Permit NO. Demo-21-0796 ..•,,' City of Arcadia, CA Development Services Department Permit Type:Demolition 240 West Huntington Drive,Post Office Box 60021 Work Classification:Demo/Pool Arcadia,CA 91066-6021 (626)574-5416 Permit Status:Issued ARCADIA Issue Date:04/30/2021 Expiration: 05/02/2022 Addr NO. Dir Prefix Street Name Street Suffix Unit City,State,Zip Parcel Number 470 LOS ALTOS AVE Arcadia,CA 91007-8332 5787015008 Contacts NANCY HUANG Owner ACE DEMOLITION CORPORATION* Contractor 470 LOS ALTOS 6924 CANBY AVE 120,RESEDA,CA 91335 (562)882-1061 (818)223-3366 833408 Description:DEMO INGROUND POOL AND SPA 120 PF Valuation: $ 0.00 Tenant Total Sq Feet: 0.00 Plan Check# Plan# Fees Amount Payments Amount Paid Demolition Permit(Pool/Spa Backfill) $53.00 Total Fees $106.26 Demolition Permit Issuance Fee $47.01 Cash/Receipt#REC-07493-21 $106.26 Solid Waste Management Fee $6.25 Amount Due: $0.00 Total: $106.26 k 5--21---2.( /74c,Ec /.f Xicre— 41 o''A— ,77-o #.(4 �� /1-:..,7 /' CALLS FOR INSPECTIONS 6-3 2/ ,/1-G G/Ejh0 ` Request for inspection by telephone at 626-574-5450. Leave a message requesting the address,timeframe and what inspection item is needed. This permit/plan review expires by time limitation and becomes null and void if the work authorized by the permit is not commenced within 180 days from the date of issuance or if the permit is not obtained within 180 days from the date of plan submittal.This permit expires and becomes null and void if any work authorized by this permit is suspended or abandoned for 180 consecutive days or if no progressive work has been verified by a City of Arcadia building inspector for a period of 180 consecutive days. April 30, 2021 Issued By: Henry Kemick Date April 30,2021 Page 1 of 1 'BA• 4 !PERMIT/PLAN REVIEW APPLICATION e its*, Development Services Department,240 West Huntington Drive,Post Office Box 60021 mo. et N° Arcadia, CA 91066-6021, (626) 574-5416,Fax (626) 447-9173 City of Arcadia LICENSED CONTRACTOR'S DECLARATION WORKERS'COMPENSATION DECLARATION ❑ I hereby affirm under penalty of perjury that I am licensed under provisions of I hereby affirm under penalty of perjury one of the following: Chapter 9(commencing with Section 7000,of Division 3 of the Business and Professions Code,and my license is in full force and effect. / ❑ I have and will maintain a certificate of consent to self-insure for workers' License Class C r icense No. 1.- Yo g Exp. Date 3/3//22 compensation, as provided for by Section 3700 of the Labor Code, for the Signature of Contractor ec--2� performance of the work for which this permit is issued. OWNER-BUILDER DECLARATION ❑ I have and will maintain workers'compensation insurance,as required by Section ❑ I hereby affirm under penalty of perjury that I am exempt from the Contractors 3700 of the Labor Code,for the performance of the work for which this permit License Law for the following reason(Section 7031.5,Business and Professions is issued.My workers'compensation insurance carrier and policy numbers are: Code.Any city or county which requires a permit to construct,alter,improve, Carrier `-7/1:(e- ce-,.-t PZ'.i —ff o.`) demolish,or repair any structure,prior to its issuance,also required the applicant /q 67_3' 9 for such permit to file a signed statement that he or she is licensed pursuant to the Policy Number provisions of the Contractors License Law(Chapter 9(commencing with Section (This section need not be completed i the pernrit is for one hundred dollars or less) 7000)of Division 3 of the Business and Professions Code)or that he or she is exempt there from and the basis for the alleged exemption. Any violation of ❑ I certify that in the performance of the work for which this permit is issued,I shall Section 7031.5 by any applicant for a permit subjects the applicant to a civil not employ any person in any manner so as to become subject to the workers' penalty of not more than five hundred dollars($500)): compensation Laws of California,and agree that if I should become subject to the workers'compensation provisions of Section 3700 of the Labor Code,I shall 0 I, as owner of the property, or my employees with wages as their sole forthwith comply with those provisions. compensation,will do the work,and the structure is not intended or offered forg 11------ sale(Section 7044,Business and Professions Code:The Contractors License Date IS,/ 2 i Signature Law does not apply to an owner of property who builds or improves thereon, or who does such work himself or herself or through his or her own employees,provided that such improvements are not intended or offered for WARNING: Failure to secure Workers'Compensation coverage is unlawful, sale.If,however,the building or improvement is sold within one(1)year of and shall subject an employer to criminal penalties and civil fines up to one completion,the owner-builder will have the burden of proving that he or she hundred thousand dollars($100,000),in addition to the cost of compensation, did not build or improve for the purpose of sale). damages as provided for in Section 3706 of the Labor Code, interest, and attorney's fees. 0 I, as owner of the property, am exclusively contracting with licensed contractors to construct the project(Section 7044, Business and Professions Code:The Contractors License Law does not apply to an owner of property CONSTRUCTION LENDING AGENCY who builds or improves thereon,and who contracts for such projects with a I hereby affirm under penalty of perjury that there is a construction lending agency contractor(s)licensed pursuant to the Contractors License Law). for the performance of the work for which this permit is issued (Section 3097, Civil Code). ❑ I am exempt under Section 7044,Business and Professions Code,for this reason: Lender's Name Date Signature Lender's Address IMPORTANT: APPLICATION IS HEREBY MADE TO THE BUILDING OFFICIAL FOR A PERMIT SUBJECT TO THE CONDITIONS ANI) RESTRICTIONS SET FORTH ON THIS APPLICATION AND THE FOLLOWING: 1. The City's approved plans and permit inspection card must remain on the job site for use by City inspection personnel. 2. Final inspection of the work authorized by this permit is required.A Certificate of Occupancy must be obtained prior to use and occupancy of new buildings and structures. 3. Per South Coast Air Quality Management District(AQMD)regulations,renovation and remodeling work that results in the removal,stripping,or altering of asbestos containing materials requires an asbestos survey and removal prior to disturbing the asbestos. Please contact AQMD at(909) 396-2000 for further information. ,er Name r!>,,,L 4tv i 9-a---/ S \Titlerr = nr r //lid c'"7- PRINT NAME I certify that I have read this application and state that the above information is correct and that I am the owner or duly authorized agent of the owner. I agree to comply with all City ordinances and State Laws relating to building construction. I hereby authorize representatives of the City of rcadia to enter upon the above-mentioned property for inspection purposes. ignature Date y/3 0/2/ vn N l Sol s 03 1 AC 0 7s Y o � SPA• p( o t,., r8 4 7 o 4 Yo SO 2g $o 41° Go ASE . /4(1. •A.Dta1 4/4 9f00.7 DEVELOPMENT SERVICES DEPARTMENT PLAN REVIEW/ • BUILDING AND SAFETY --; 240West Huntington Drive BUILDING PERMIT City of P.O. Box 60021 APPLICATION Arcadia Arcadia, CA 91066-6021 (626) 574-5416 FORM BUILDING 470 Los Altos Ave., Arcadia, CA 91007 ADDRESS Bertran Hsieh; Nancy Huang OWNER MAILING 470 Los Altos Ave. ADDRESS Arcadia CA I 91007 562-882-1061 CII 1 STA]C 1ZJP TELEPHONE Ace Demolition CONTRACTOR 6924 Canby Ave., Suite 120 ADDRESS ResedaCA 91335 818-223-3366 CITY I STATE ZIP TELEPHONE STATE LIC 833408 C-21 CITY 047928 &CLASSIF LIC NO. Paul Andrews APPLICANT 6924 Canby Ave., Suite 120 ADDRESS 1 Reseda CA 91335 818-223-3366 ISTATE ZIP TELEPHONE PROPOSED Demolition and disposal of swimming pool and spa, leaving the shell in place. CONSTRUCTICY, Backfill w/ compacted earth, approx. 115 cyds. REMODELED NEW SQUARE FT.OF SQUARE FT MAIN STRUCTURE NEW SQUARE FT.OF ACCESSORY NEW SQUARE FT.OF STRUCTURE(SPECIFY) PATIO(S)/PORCH(ES) NEW SQUARE FT.OF MISCELLANEOUS STRUCTURE(S)(SPECIFY) -.--.--.-.----..-.---.-- OCCUPANCY CLASSIFICATION(S) TYPE OF C4CDO .E)e7 CONSTRUCTION VALUATION7 • REV 5103 Submit for Review A 1 _ A. G. I. GEOTECHNICAL, INC. 16555 Sherman Way, Suite A-Van Nuys, CA 91406-Office: (818)785-5244- Facsimile: (818)785-6251 May 17, 2021 Project No. 31-9999-130 Ace Demolition Corp. 6924 Canby Ave., Suite 120 Reseda, CA 91335 Attention: Mr. Eric Asseraf Subject: SOILS COMPACTION REPORT PRIMARY STRUCTURAL FILL Swimming Pool Excavation Backfill Tract: 11678; Lot: 17 470 Los Altos Avenue Arcadia, California Dear Mr. Asseraf: This report presents the results of observation and testing performed during the preparation and placing of compacted backfill for the swimming pool excavation at the subject site. The compacted fill reported herein is considered primary structural fill for support of footings and slabs. Compaction tests were performed in accordance with ASTM:D-1556 (Sand Cone Method) and ASTM:D-2922. The test locations and limits of compacted fill are shown on the enclosed Compaction Map. Results of the tests are tabulated on the enclosed "Compaction Test Results". SITE PREPARATION The area of the pool excavation which was backfilled was approximately 17 to 24 feet wide by 32 to 40 feet long, as shown on the enclosed Compaction Map. The maximum depth of the excavation was approximately six feet. Prior to any backfill, the bottom of the shell had 24" x 24" drain holes opened every 8' and the upper approximately 24" of the shell of the old pool was demolished and the debris hauled away. The bottom of the excavation was cleared of all trash and debris and was observed and approved by us on May 3, 2021. FILL PLACEMENT Import soils were used to construct the fill and consisted of clayey sand. The fill material was placed in 6- to 8-inch lifts, watered to optimum moisture content, mixed and compacted to a minimum of 90% of the maximum dry density as determined by ASTM:D-1557. Equipment used in placing and compacting the fill consisted of a small rubber tire loader, a vibratory compactor, hand tampers and watering equipment. Engineering Geology - Soil Engineering Ace Demolition Corp. Page 2 Project No. 31-9999-130 470 Los Altos Street May 17, 2021 The maximum dry density/optimum moisture of the fill soils was determined in accordance with ASTM:D-1557. Results of the tests are tabulated on the enclosed "Laboratory Test Results". EXPANSIVENESS An expansion test was performed on a typical sample of the material obtained. The sample was tested in accordance with ASTM:D-4829 under a surcharge of 144 lb/ft2. The following result was obtained: Sample Depth (ft.) Soil Type Expansion Index Potential Expansion 0 - 1 Clayey SAND 24 Low (Import) DIRECT SHEAR TEST (ASTM:D-3080) In order to determine the shear strength of the soils, a direct shear test was performed on a remolded sample of the import soils. The remolded sample was tested at 90% of the maximum density. To simulate possible adverse field conditions, the sample was saturated prior to shearing. A graphic summary of the test result, including moisture content at the time of shearing, is enclosed. SOIL BEARING PRESSURE Conventional continuous and spread footings founded on compacted fill may be designed for a maximum soil bearing pressure of 2,000lb/ft2. Based on the potential expansion, minimum embedment for the footings should be 18 inches and 24 inches below the lowest adjacent grade for 1-story and 2-story buildings, respectively. The footings should have a minimum width of 15 inches. Continuous footings should have a minimum reinforcement consisting of four No. 4 bars: two placed about four inches from the top and two placed about four inches from the bottom. Floor slabs-on-grade should reflect its anticipated usage and should be designed by the structural engineer. In areas where floor coverings or equipment sensitive to moisture are contemplated, a 10-mil visqueen should be placed beneath the slab with one inch of sand between the concrete slab and the visqueen to aid in curing and prevent puncture of the visqueen. A.G.I. Geotechnical, Inc. • 16555 Sherman Way, Suite A • Van Nuys, CA 91406 [nl Office: (818)785-5244 • Facsimile: (818)785-6251 Ace Demolition Corp. Page 3 Project No. 31-9999-130 470 Los Altos Street May 17, 2021 CONCLUSIONS At the locations and elevation tested by us, the fill for the excavation was compacted to at least 90% of the maximum dry density as determined by ASTM:D-1557. In providing professional geotechnical observations and testing services associated with the development of this project, we have employed accepted engineering and testing procedures and have made every reasonable effort to ascertain that the soil related work was carried out in general compliance with the project plans and specifications. Although our observations did not reveal obvious deficiencies, we do not guarantee the contractor's work, nor do the services performed by our firm relieve the contractor of responsibility in the event of subsequently discovered defects in his work. We appreciate this opportunity to be of service. If you have any questions, please do not hesitate to contact this office. Respectfully submitted, oPROFEssioN A.G.I. GEOTECH ICAC, INC. �`������R�cs`04.. � Z No 2673//5 Bruce Smit , .G. . 2673 * EXP.06-30-22 Senior Engineer �F ST9TorFCHN\�P�P MBS:mg °FCALIFOC Enclosures: Compaction Map Compaction Test Results Laboratory Test Results Engineer's Certificate Distribution: (4)Addressee A.G.I. Geotechnical, Inc. • 16555 Sherman Way, Suite A • Van Nuys, CA 91406 LAW-,JOffice: (818)785-5244 • Facsimile: (818)785-6251 O o, d• ° s0go) II " mom ---.......6.4...... .- ::: -.......6 : _ � 1mm z ~ t3 ° 2 > U Ob' w — neeCI a a Iv G- U/� CA CI •�.I-y V I CI Qy U z : = \ , of -- i&r,. I I .* Wa O 47r, 1 cKs u) •~ = E o N — w CI N ,0 0 a) a c/ +' C U s i 5 r •- cd NWc • >C W C14 1- ir t7 'e MI E O o O -u `A Q � U a • �' U = IIIII P.! -, ® II111 w . I 1 COMPACTION TEST RESULTS PROJECT NO. 31-9999-130 DATE: 05/17/21 TEST DATE ELEVATION/ MOISTURE UNIT DRY RELATIVE SOIL REMARKS NO. DEPTH BELOW CONTENT DENSITY COMPACTION TYPE FINISH GRADE (%) (LB/FT3) (%) (FT.) 1 05/07/21 4.0 11.2 111 93 1 2 05/10/21 3.0 12.4 108 90 1 3 05/11/21 2.0 12.1 110 92 1 4* 05/12/21 1.0 11.9 109 91 1 Sand Cone 5* 05/13/21 F.G. 11.7 110 92 1 Sand Cone Note: * Denotes compaction tests that were performed using the Sand Cone Method. LABORATORY TEST RESULTS PROJECT NO. 31-9999-130 DATE: 05/17/21 SOIL CLASSIFICATION MAXIMUM OPTIMUM TYPE DENSITY MOISTURE (LE3/FT3) (%) 1 Clayey SAND (Import) 119.5 11.5 DIRECT SHEAR TEST REMOLDED SATURATED SAMPLE @ 90% MAXIMUM DENSITY • 5000 4000 - F= a ti u) 3000 w=17.5 %, cn 1 re < 2000 w ' 11111111w=17.7 w=17.8 % 1000 - , 111111 0 0 1000 2000 3000 4000 5000 NORMAL STRESS (LBS/SQ FT) PROJECT NO. 31-9999-130 BORING NO. Import DEPTH (FT) Stockpile REPRESENTATIVE FOR Import SOIL TYPE AND DESCRIPTION Clayey SAND (SC) COHESION, C (LBS/SQ FT) 387 FRICTION, 4 (DEG) 27.9 METHOD OF COMPACTION AgASTM:D-1557 A.G.I. GEOTECHNICAL, INC. A __ s `. County of Los Angeles ly 1 Department of Public Works MALI* on Building and Safety Division r r,c� ENGINEERED GRADING CONSULTANT STATEMENT (Submit to the local Office of Building and Safely prior to Rough and Final Inspection) Job Address or Tract No.: 470 Los Altos Avenue Locality: Arcadia Permit No.: Owner: Contractor: Ace Demolition Corp. ROUGH GRADING COMPLETION OF WORK-SECTION 3318.LOS ANGELES COUNTY BUILDING CODE U CIVIL ENGINEER Based upon field observations, rough grading of the lots listed below has been completed In conformance with Sections 3317 and 3318 of the Los Angeles County Building Code. The work includes, but is not limited to, the following: grading to approximate final elevations; staking of property lines; location and gradient of cut and fill slopes; construction of required drainage devices. Building pads are free from flood hazard in conformance with Section 110 of the Los Angeles County Building Code. Latest approved plan revision dated: Lot No.(s): Other Areas: Remarks: Engineer: Reg.No.: Date: (Sig nature) 21 Soils Engineer Based upon tests and observations,the earth fills placed on the following lots were Installed upon properly prepared base material and compacted In compliance with requirements of Sections 3317 and 3318 of the Los Angeles County Building Code. Fill slope surfaces have been compacted and buttress fills or similar stabilization measures have been Installed in accordance with my recommendations as approved by the Building Official. Sub-drains have been provided where required, and locations of said sub-drains are shown OR as-graded plans and/or rough grade reports dated . See report dated 05/17/21 for compaction test data and procedure, recommended allowable soil bearing values,and other special recommendations. Lot No.(s): EXPANSIVE SOILS (YES) (NO) LOT No.(s): 17 BUTTRESS FILLS (YES) (NO) LOT No.(s): REINFORCED EARTH WALLS (YES) (NO) LOT No.(s): �oQoFESSSoNal RESTRICTED USE AREAS (YES) (NO) LOT No.(s): �,� \�gRUCFs F,y z,�, 4% arks: m No.2673 z Exp.06-30-22 4 5."I s °FOT \�P� E r neer: Reg. No.: 2673 Date: 05/17/21 TqT ECHN ��P (signature) oFCAUF��` Bruce Smith ) 1